Tools Safety 2 handouts Bode Plots lecture notes pset1
Transcript of Tools Safety 2 handouts Bode Plots lecture notes pset1
![Page 1: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/1.jpg)
• Tools & Safety•Resonance• Bode Plots• Wires – theory vs reality• Amplitude Modulation• Diodes
6.101 Spring 2020 Lecture 2 1
Acknowledgements: Lecture material adapted from Prof Qing Hu & Prof Jae Lim, 6.003Figures and images used in these lecture notes by permission,copyright 1997 by Alan V. Oppenheim and Alan S. Willsky
2 handoutslecture notespset1
![Page 2: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/2.jpg)
Lab & Checkoff Logistics
• Open lab with no scheduled lab sessions – lab can be done any time the lab is open.
• Start early – 32 students with 17 + 6 lab stations • Staffed lab hours posted.• Material on cart and round table; additional parts available from parts bins near the center columns and from EDS 38‐500.
• Lab reports should be turned in for grading.
6.101 Spring 2020 2
![Page 3: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/3.jpg)
Tools & Safety
• Correct tools makes life easier!
• Understand power ratings.
• All EECS Instructional Laboratories lab kit voltages are below 50 volts peak or 50 volts DC. See staff if you are working with voltages greater than 50 volts.
• All students must read and sign the safety form https : / / eecs‐ug.scripts.mit.edu:444/safety/index.py/6.101
6.101 Spring 2020 3
![Page 4: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/4.jpg)
Decibel (dB) – 3dB point
i
o
VVdB log20
i
o
PPdB log10
6.101 Spring 2020 4
3 dB point = ?
log10(2)=.301
Lecture 2
100 dB = 100,000 = 105
80 dB = 10,000 = 104
60 dB = 1,000 = 103
40 dB = 100 = 102half power point
![Page 5: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/5.jpg)
Resonance (Series RLC) – Key points
6.101 Spring 2020 5
R LC
+V-
)1(1C
LjRsC
sLRZ
• Applies to more complex RLC circuits
• At resonance: power is maximum
• At resonance: phase angle zero, i.e. capacitive reactance = inductive reactance, or impedance is real
Lecture 2
![Page 6: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/6.jpg)
Bandwidth and Q (Series RLC)
6.101 Spring 2020 6Lecture 2
• BW (hertz) =
• Q* (quality factor, radians)
• Higher Q implies more selectivity
LRlh
22
resonant frequencybandwidth
*Agarwal/Lang Foundation of Analog Digital Elect Circuits equation 14.47, p 794
CL
RQ 1
![Page 7: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/7.jpg)
Summary – Parallel Series RLC
6.101 Spring 2020 7
Parallel Series
Lecture 2
RLfQ O2
LCfO 2
1
RCfQ o2
LRffBW lh 2
)( RC
ffBW lh 21)(
LCf
fLC
21
21
0
00
Parallel Series
LCfO 2
1
![Page 8: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/8.jpg)
Series Parallel Duality
6.101 Spring 2020 8
I
R L
CV I R L C+V-
I V 1R 1
jwL jwC
jwCjwLRIV 1
Series Parallel
V I
R 1/R
L C
C L
![Page 9: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/9.jpg)
6.101 Spring 2020 9
https://web.njit.edu/~levyr/Physics_121/chapter32.ppt
![Page 10: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/10.jpg)
Bode Plot ‐ Review
• A Bode plot is a graph of the magnitude (in dB) or phase of the transfer function versus frequency.
• Magnitude plot on log‐log scale– Slope: 20dB/decade, same as 6dB/octave
• Bode plot provides insight into impact of RLC in frequency response.
• Stable networks must always have poles and zeroes in the left‐half plane.
6.101 Spring 2020 10Lecture 2
![Page 11: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/11.jpg)
MATLAB
• Matlab windows: current folder, command, work space (workspace), command history (commandhistory)
• Set folder to your favorite folder
• Built in help in command window
• docking/undocking
Current folder
Command window Workspace
Command history
![Page 12: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/12.jpg)
MATLAB commands
• % comment delimiter• MATLAB arrays starts with index=1
– a = [4,5,6] is a row vector a(2)=5– b = [7;8;9] is a column vector
• “;” don’t print values• Variables are case sensitive • Variables must start with a letter• who/whos: list the current variables in short/long form• shg – show recent graph, pop to the front• use apostrophes for FILENAME• format shortENG – display engineering notation
aA
![Page 13: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/13.jpg)
MATLAB
pi 3.14159265i,j sqrt(-1) imaginary unit
zeros(n,m) an n x m matrix of zerosones(n,m) an n x m matrix of ones
+ - addition, subtraction*/ ^ multiplication, division, power
sqrt square root
![Page 14: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/14.jpg)
MATLAB Matrix Operation
>> a=[2,3,4]a = 2 3 4
>> b=[1,0,0]b = 1 0 0
>> c=a+bc = 3 3 4
>> d=a*b % dot product operation??? Error using ==> mtimesInner matrix dimensions must agree.
>> d=a.*bd = 2 0 0
>> e=a*b' % ' transposee = 2
![Page 15: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/15.jpg)
MATLAB Flow Control
• if else statement
• for loop
• while loop
if a == 0b = a;
elseb = 1/a;
end
n = 100for m = 1:n
a(m) = a(m) + 1;end
n = 10while n > 0
n = n – 1end
![Page 16: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/16.jpg)
MATLAB example sin(x)
>> t=[0:1/100:1-1/100]; % create t from 0 to .99, 100 values>> x=sin(2*pi*t);>> plot(t, x);>> stem(t,x);>> shg
![Page 17: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/17.jpg)
6.101 Spring 2020 17
MATLAB Functions bode, freqs
• BODE(SYS,W) uses the vector W of frequencies (in radians/TimeUnit) to evaluate the frequency response
• [MAG,PHASE] = BODE(SYS,W) and [MAG,PHASE,W] = BODE(SYS) return the response magnitudes and phases in degrees (along with the frequency vector W if unspecified).
• SYS is the transfer function expressed as numerator and denominator in the form
• bode(num,denom,range)num=[d e], denom=[a b c], range= desired freqencies in radians
• freqs(num,denom,range) plots frequency response and phase angle
SYS d eSaS2 bS c
![Page 18: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/18.jpg)
Bode vs Freqs Plots
6.101 Spring 2020 18freqs
R=1 L=47uh C=1.8nf f=540khz
format shortENGnum=[1/L 0]denom=[1 R/L 1/(L*C)]f=1/(2*pi*sqrt(L*C))w=2*pi*fw_range = [.8*w:20:1.2*w];h=bode(num,denom,w_range);magh=abs(h);plot(w_range,magh)shgfreqs(num,denom,w_range)
bode not same scale Lecture 2
1
1
![Page 19: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/19.jpg)
Bode in Hz
6.101 Spring 2020 19
R=1 L=47uh C=1.8nff=540khz
[Mag, Phase, W] = bode(num, denom, w_range);Freq_Hz = W/2/pi;Mag_dB = 20*log10(Mag);subplot(2,1,1)semilogx(Freq_Hz, Mag_dB)title('Bode Diagram')ylabel('Magnitude (dB)')subplot(2,1,2)semilogx(Freq_Hz,Phase)xlabel('Frequency (Hz)')ylabel('Phase (deg)')shg
Lecture 2
1
1
![Page 20: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/20.jpg)
Selectivity and Q
6.101 Spring 2020 20
L=47uh C=1.8nf f=540khz
R Q
1 160
5 32
10 16
Lecture 2
![Page 21: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/21.jpg)
6.101 Spring 2020 21
r=1l=4.7e-5c=1.8482e-009num=[1/l 0]denom=[1 r/l 1/(l*c)]f=1/(2*pi*sqrt(l*c))w=2*pi*fw_range = [.8*w:20:1.2*w][w,mag1]=bode_gh(1,l,c)[w,mag5]=bode_gh(5,l,c)[w,mag10]=bode_gh(10,l,c)hold onplot(w,mag1)plot(w,mag5/max(mag5),'r-')shgplot(w,mag10/max(mag10),'g-')shgxlabel('w(rad/sec)')shgylabel('Amplitude')shgtitle(' Response for RLC series circuit')shg
bw1=1/(2*pi*l)q1=f/bw1bw5=5/(2*pi*l)q5=f/bw5bw10=10/(2*pi*l)q10=f/bw10
>> bw1=1/(2*pi*l)bw1 = 3.3863e+003>> ff = 5.4000e+005>> q1=f/bw1q1 = 159.4683>> bw5=5/(2*pi*l)bw5 = 1.6931e+004>> q5=f/bw5q5 = 31.8937>> bw10=10/(2*pi*l)bw10 = 3.3863e+004>> q10=f/bw10q10 = 15.9468
![Page 22: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/22.jpg)
Selectivity and Q
6.101 Spring 2020 22
L=47uh C=1.8nf f=540khz
R Q
1 160
5 32
10 16
Lecture 2
![Page 23: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/23.jpg)
Lab 1 Topics
• Resonance, Q, bandwidth• Transformers and impact on load and bandwidth
• Diode detector, demodulation• Simple AM transmitter and receiver
6.101 Spring 2020 23
![Page 24: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/24.jpg)
Proper External Grounding forLab 1 IF Transformer
6.101 Spring 2020 24
NC
Can
PC Boardpri sec
Lecture 2
![Page 25: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/25.jpg)
6.101 Spring 2020 25
Schematics & Wiring• IC power supply connections generally not drawn.
All integrated circuits need power!• Use standard color coded wires to avoid confusion.
– red: positive – black: ground or common reference point– Other colors: signals
• Circuit flow, signal flow left to right• Higher voltage on top, ground negative voltage on
bottom• Neat wiring helps in debugging!
![Page 26: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/26.jpg)
6.101 Spring 2020 26
Wire Gauge
• Wire gauge: diameter is inversely proportional to the wire gauge number. Diameter increases as the wire gauge decreases. 2, 1, 0, 00, 000(3/0) up to 7/0.
• Resistance– 22 gauge .0254 in 16 ohm/1000 feet– 12 gauge .08 in 1.5 ohm/1000 feet– High voltage AC used to reduce loss
• 1cm cube of copper has a resistance of 1.68 micro ohm (resistance of copper wire scales linearly : length/area)
![Page 27: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/27.jpg)
Wires Theory vs Reality ‐ Lab 1
6.101 Spring 2020 Lecture 2 27
Wires have inductance and resistance
noise during transitions
Voltage drop across wires
LC ringing after transitions
30-50mv voltage drop in chip
power supply noise
![Page 28: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/28.jpg)
Bypass (Decoupling) Capacitors
6.101 Spring 2020 Lecture 2 28
Bypass capacitor0.1uf typical
• Provides additional filtering from main power supply
• Used as local energy source – provides peak current during transitions
• Provided decoupling of noise spikes during transitions
• Placed as close to the IC as possible.
• Use small capacitors for high frequency response.
• Use large capacitors to localize bulk energy storage
Electrolytic Capacitor 10uf
Through hole PCB (ancient) shown for clarity.
![Page 29: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/29.jpg)
6.101 Spring 2020 29
The Concept of Modulation (modulating a carrier)
Why?• More efficient to transmit E&M signals at higher frequencies.• Transmitting multiple signals through the same medium using
different carriers.• Increase signal/noise ratio in lock‐in measurements.• others...
How?• Manymethods
x(t) Transmitted Signal
Carrier Signal
Lecture 2
![Page 30: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/30.jpg)
Two of Many Methods of Modulation
6.101 Spring 2020 30
Focus is on Amplitude Modulation (AM)
![Page 31: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/31.jpg)
Fourier Series
6.101 Spring 2020 31
T= 1/f1
V=|Asin(ω0t)| ω0 = 2π f1
?
?
?
1(n1)
n
![Page 32: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/32.jpg)
Time Domain Analysis
6.101 Spring 2020 32
])cos()[cos(2
cos
cos*)cos(
ttKAtAv
ttKAAv
mcmcm
cc
cmmc
Lecture 2
![Page 33: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/33.jpg)
6.101 Spring 2020 33
Amplitude Modulation (AM) of a Complex Exponential Carrier
c t ej c t , c — carrier frequency
y(t) x(t) ej ct
X j c
Y j 12
X j C j
1
2X j 2 c
Lecture 2
![Page 34: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/34.jpg)
6.101 Spring 2020 34
Asynchronous Demodulation
• Assume c >> M, so signal envelope looks like x(t)• Add same carrier
A + x(t) > 0 why?Frequency Domain
Time Domain
Lecture 2
![Page 35: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/35.jpg)
AM with Carrier (for different Amplitudes of A)
6.101 Spring 2020 35
t
t
t
)()()( tctxty m
)(tc
)(txm
)()( tcAtxm
![Page 36: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/36.jpg)
6.101 Spring 2020 36
Asynchronous Demodulation (continued)Envelop Detector
In order for it to function properly, the envelop function must be positive definite, i.e. A + x(t) > 0.
Simple envelop detection for asynchronous demodulation.
D1
D1: 1N914 or 1N4148
Lecture 2
![Page 37: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/37.jpg)
6.101 Spring 2020 37
Units
Lecture 2
![Page 38: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/38.jpg)
Standard Values
6.101 Spring 2020 38
![Page 39: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/39.jpg)
Diodes
6.101 Spring 2020 39
)1( kTqv
sD
D
eII
kT/q is also known as the thermal voltage, VT.
VT = 25.9 mV = ~ 26mv when T = 300K, room temperature.
Lecture 2
![Page 40: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/40.jpg)
Finger Tips Facts
• Current thru pn junction doubles for every 26mv (at room temperature) or 10x for every 60mv
• Temperature coefficient of silicon diode is ~2mv/degC at room temperature
• Small signal resistance of pn junction is1 ohm @26 ma, 26 ohm @1ma
6.101 Spring 2020 40
![Page 41: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/41.jpg)
Diode V‐I Characteristic
6.101 Spring 2020 41
ID IseqvDkT
kTq 26mv
Is 10pa
Lecture 2
thermal voltage
![Page 42: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/42.jpg)
Reverse Breakdown Voltage
6.101 Spring 2020 42
Low doped diodes have higher breakdown voltage
http://en.wikipedia.org/wiki/File:Diode_current_wiki.png
Lecture 2
![Page 43: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/43.jpg)
6.101 Spring 2020 43
Zener Diode
• Zener diodes will maintain a fixed voltage by breaking down at a predefined voltage (zenervoltage).
4.7k
+
V
_
Lecture 2
![Page 44: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/44.jpg)
Zener Breakdown
• Actually caused by two effects: avalanche effect and zener effect.
• Avalanche effect: electron/holes entering depletion region is accelerating by the electric field, collides and creates additional electron/hole pairs – like a snow avalanche; occurs above 5.6V; has positive temperature coefficient
• Zener effect: heavy doping of PN junction results in a thin depletion layer. Quantum tunneling results in current flow; occurs below 5.6V; has negative temperature coefficient
• At 5.6V, two effects balance is near zero temperature coefficient.
6.101 Spring 2020 44
![Page 45: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/45.jpg)
6.101 Spring 2020 45
![Page 46: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/46.jpg)
1N4001‐1N4007
6.101 Spring 2020 46
![Page 47: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/47.jpg)
Transient Respopnse
6.101 Spring 2020 47
Fast reverese recovery diode needed for switching power supplies
Lecture 2
![Page 48: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/48.jpg)
Diodes
6.101 Spring 2020 48
Type Max Vr Max IContinous
Recoverytime
Capaciitance
1N914 75V 10ma 4ns 1.3pf
1N4002 100V 1000ma 3500ns 15pf
1N5625 400 3000ma 40pf
1N1084 4000 30,000ma(peak)
400 50,000ma
Lecture 2
![Page 49: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/49.jpg)
6.101 Spring 2020 49
1N4001
1N914, 1N4148
1N7XX
Pulse Ox
Diode types
Lecture 2
![Page 50: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/50.jpg)
Diode Circuits
6.101 Spring 2020 50Lecture 2
![Page 51: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/51.jpg)
6.101 Spring 2020 51
RC Equation
dtdVC c
cc V
dtdVRC
Vs = 5 V
Switch is closed t<0
Switch opens t>0
Vs = VR + VC
Vs = iR R+ Vc iR =
Vs =
R
+Vc-
Vs = 5 V
RCt
sc eVV 1
RCt
c eV 15
Is RC in units of time?
Lecture 2
![Page 52: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/52.jpg)
More Diode Circuits
6.101 Spring 2020 52Lecture 2
![Page 53: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/53.jpg)
Clamping Circuit
6.101 Spring 2020 53
RC time constant limitation
Lecture 2
![Page 54: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/54.jpg)
6.101 Lecture 2 54
Light Emitting Diode
• LED’s are pn junction devices which emit light. The frequency of the light is determined by a combination of gallium, arsenic and phosphorus.
• Red, yellow and green LED’s are in the lab• Diodes have polarity• Typical forward current 10‐20ma
![Page 55: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/55.jpg)
6.101 2020 Lecture 2 55
Optical Isolators
• Optical Isolators are used to transmit information optically without physical contact.
• Single package with LED and photosensor (BJT, thyristor, etc.)
• Isolation up to 4000 Vrms
• Used in pulse‐oximetryNellcor DS-100 Pulse-ox
![Page 56: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/56.jpg)
Pulse‐Oximetery
• A non‐invasive photoplethysmographical (PPG) approach for measuring pulse rate and oxygen saturation in blood.
• Oximetry developed in 1972, by Takuo Aoyagi and Michio Kishi
• Commercialized by Biox in 1981 and Nellcor in 1983.
6.101 2016 Lecture 2 56
![Page 57: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/57.jpg)
Pulse‐Oximetry Sensor
6.101 2016 Lecture 2 57
http://energymicroblog.files.wordpress.com/2012/11/figure-1.png
Why plastic DB-9?
finger
![Page 58: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/58.jpg)
Pulse‐Oximetry
• Two measurements:– Pulse rate– Oxygen saturation – Challenge: measuring
5‐20 nA!
• Heart rate easily accomplished with two IC’s!
6.101 2016 Lecture 2 58
![Page 59: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/59.jpg)
Reflective PPG*
*Fitbit Patent: US 2014/0275852 Wearable Heart Rate Monitor
![Page 60: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/60.jpg)
“Fitbit” Lab
Lecture 2 60
SFH 7050: 3 leds, 1 photodiode in one package
![Page 61: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/61.jpg)
Transimpedance Amplifier(Current to Voltage Converter)
Lecture 2 61
Ir
Ir = Ip
Vout = Ip Rf
http://en.wikipedia.org/wiki/File:TIA_simple.svg
![Page 62: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/62.jpg)
Transimpedance Amplifier(Current to Voltage Converter)
Lecture 2 62
Idiode
At low frequency
outV
3RIV diodeout
mvVxRxI
out
diode
201043105 69
0.96V
![Page 63: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/63.jpg)
“Fitbit” Lab
Lecture 2 63
Virtual ground at 4.5V not shown
negative battery terminal
![Page 64: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/64.jpg)
64
Voltage
• What is the equation describing the voltage from a 120VAC outlet?
• 120 VAC is the RMS (Root Mean Square Voltage)• 60 is the frequency in hz• Peak to peak voltage for 120VAC is 340 volts!
340 V
tt 602sin7.169602sin2120
6.101 Spring 2020
![Page 65: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/65.jpg)
65
RMS Voltage• The RMS voltage for a sinusoid is that value
which will produce the same heating effect (energy) as an equivalent DC voltage.
• Energy =
• For DC,
• Equating and solving, A =
t = π
tAv sin
dtvr
vidtPdt
0
2
0
1
rvrms 2
rmsv
2 rmsvi
+
-v
6.101 Spring 2020
![Page 66: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/66.jpg)
66
RMS Derivation
][ 00
2 2sin41
2sin
ttdt
tdtAr
dtvrr
vrms 2
0
2
0
22
sin11
][ 0
22
2sin41
2 tt
rA
rvrms
2 rmsvA =
6.101 Spring 2020
![Page 67: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/67.jpg)
6.101 Spring 2020 67
Agilent Function Generator
Turn on output!
![Page 68: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/68.jpg)
6.101 Spring 2020 68
Agilent DMM
![Page 69: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/69.jpg)
6.101 Spring 2020 69
Oscilloscope Controls
• Auto Set, soft menu keys
• Trigger – channel, – slope, – Level
• Input– AC, DC coupling, – 10x probe, – 1khz calibration source,– probe calibration,– bandwidth filter
• Signal measurement– time, – frequency, – voltage– cursors– single sweep
• Image captureData export
![Page 70: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/70.jpg)
70
Tektronix Oscilloscope
Menu driven soft key/buttons
![Page 71: Tools Safety 2 handouts Bode Plots lecture notes pset1](https://reader034.fdocuments.in/reader034/viewer/2022042623/62648b81e1ad291fb8607b9e/html5/thumbnails/71.jpg)
71
Agilent Oscilloscope
Menu driven soft key/buttons