TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
TÜV Rheinland Energy GmbH
Am Grauen Stein D-51105 Köln
Managing Director: Amtsgericht Köln HRB 56171
Telefon: Telefax:
02 21 / 8 06 – 52 00 02 21 / 8 06 – 13 49
Dirk Fenske K 2022 2017 Z1.docx
Report No. K 2022 2017 Z1
Supplement test report -Renaming-
Residential space heating appliances
acc. DIN EN 14785
Model: BIOPELLET 18
BIOPELLET 18 PLUS TERMO ORIONE PLUS
TERMO FOCUS PLUS acciaio
Trademark: FERROLI
ANSELMO COLA
Company: COLA S.r.l.
2017
This report may only be published and forwarded to third parties in its complete, unabridged form. The publication or dissemination of extracts, summaries, appraisals or any other adaptation and alterations, in particular for advertising
purposes, is only permissible with the prior written permission of TÜV Rheinland. Publication of page 2 is permitted.
The test results presented in this report refer solely to the test object stated as described on page 2. The report does not
represent a general statement about the serial production of the test object and gives not an authorization for use of a TÜV Rheinland test- / certification mark.
This accreditation is valid only for the listed standards as stated in the accreditation annex of D-PL-11120-04-00.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 2 / 7 Report no. K 2022 2017 Z1
Supplement test report -Renaming-
Residential space heating appliances fired by wood pellets DIN EN 14785: September 2006
Correction 1 DIN EN 14785: 10/2007
Applicant/contractor: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy
Trademark: FERROLI, ANSELMO COLA
Type of appliance: Residential room heating appliances fired by wood pellets with water heat exchanger, with fan assisted flue discharge and with internal fuel hopper
Model designation: BIOPELLET 18 BIOPELLET 18 PLUS
TERMO FOCUS PLUS acciaio TERMO ORIONE PLUS
Total heat input [kW]: 5,8 – 20,4 5,8 – 22,8
Water heat output [kW]: 4,8 – 17,3 4,8 – 18,1
Space heat output [kW]: 0,7 – 1,7 0,7 – 3,1
Max. water pressure: 2,0 bar
Max. water temperature: 80,0 °C
Fuels: Wood pellets (Ø 6mm, Lmax 30 mm, max humidty 5,6%, Pfeifer)
Type of fuel charging: Automatic load
Remarks: All models are all identical except than for software settings and external covering. The results of the basic initial type test (see report K 1570 2015 T1 and K 1570 2016 E6) are not affected by the renaming.
Test results: The technical requirements cl. 4-8 of the above mentioned standard are fulfilled. The local applicable installation conditions are to be observed. The electrical safety cl. 5.9 of the standard was not a part of this initial type testing. The presumption of conformity with the relevant European Directives could only be confirmed by full compliance with Annex ZA.
Cologne, 27.07.2017 432/mh
Test Centre according to Construction Product Regulation 305/2011(CPR) Notified Body: 2456
Assessor: Report released after review:
M.Sc. M. Höfinghoff Dipl.-Ing. A. Pomp
Residential space heating appliances fired by wood pellets, Initial Type Test in accordance with the regulation 305/2011
conformity certification system no. 3
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 3 / 7 Report no. K 2022 2017 Z1
1 Task
The Test Centre for Energy Appliances was instructed to execute an renaming on the above
mentioned pellet stoves.
Basic: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy Report K 1570 2015 T1
New: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy Report K 2022 2017 Z1
Trademark: COLA
Trademark: Ferroli
Model: AQUAPLUS 18
Model: BIOPELLET 18 BIOPELLET 18 PLUS
Basic: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy Report K 1570 2016 E6
New: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy Report K 2022 2017 Z1
Trademark: COLA
Trademark: ANSELMO COLA
Trademark: Ferroli
Model: TERMO PERLA PLUS
Model: TERMO FOCUS PLUS acciaio
Model: TERMO ORIONE PLUS
2 Testing
The practical tests were carried out in the laboratory in Thiene dated on the 2nd and 3rd April 2015
and 7th March 2016. The stove AQUAPLUS 18 and TERMO PERLA PLUS by Cola S.r.l. was
tested (report K 1570 2015 T1, K 1570 2016 E6). Cola S.r.l. ensures that modifications on the
above mentioned products were not carried out.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 4 / 7 Report no. K 2022 2017 Z1
2.1 Resume of test results
Types designation BIOPELLET 18
BIOPELLET 18 PLUS
Full load Partial load Requirement
Test fuel Pellets
Mass of the test fuel fired hourly kg/h 4,2 1,19 -
Flue gas mass flow g/s 10,1 5,0 -
Flue gas temperature °C 146,25 69,9 -
Flue draught mbar 0,12 0,12 0,12/0,10 +/-0,02
CO2-concentration Vol.-% 14,5 7,91 -
O2-concentration Vol.-% 5,7 12,61 -
CO-concentration ppm 130 102,2 -
CO-emission (at 13%-O2) mg/m³ 84,6 121,8 500/750 EN
CO-emission mg/kWh 201,0 289,4 -
CO-emission mg/MJ 55,8 80,4 500/750 (Art. 15a)
NOx-concentration ppm 140 78,1 -
NOx-emission (at 13%-O2) mg/m³ 149,5 152,6 -
NOx-emission mg/kWh 355,3 362,7 -
NOx-emission mg/MJ 98,7 100,7 100 (Art. 15a)
CnHm-concentration measured acc. CEN/TS 15883 mg/m³ 0,9 0,7 -
CnHm-emission (at 13%-O2) mg/m³ 0,7 1,1 -
CnHm-emission mg/kWh 1,7 2,6 -
CnHm-emission mg/MJ 0,5 0,7 30/30 (Art. 15a)
Dust concentration
measured acc. CEN/TS 15883 and EN13284-1 mg 6,3 1,3 -
Dust emission (at 13%-O2) mg/m³ 11,6 4,3 -
Dust emission mg/kWh 27,6 10,2 -
Dust emission mg/MJ 7,7 2,8 25 (Art.15a)
Particulate emission
acc. PrEN16510:2012 mg/m³ 12,1 4,7 -
Total heat output kW 19,0 5,50 -
Water heat output kW 17,3 4,82 -
Space heat output kW 1,7 0,68 -
Efficiency % 93,1 95,28 75/70 (EN14785)
80 (Art. 15a)
Maximum temperatures at trihedron:
- Left side - Back side - Floor - Front
°C °C °C °C
37,7 34,3 28,2 25,9
65K over tambient 65K over tambient 65K over tambient 65K over tambient
Distances: - Backside-Pelletstove - Side-Pelletstove - Front side Pelletstove Ambient temperature Temp. in fuel hopper Temp. operating tools (handle of
cleaning system)
mm mm mm °C °C °C
100 100 700 24,2 66,1
120,2*
65K over tambient 60K over tambient
*) A suitable glove is part of the appliance and is supplied by the manufacturer
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 5 / 7 Report no. K 2022 2017 Z1
Types designation TERMO FOCUS PLUS acciaio
TERMO ORIONE PLUS
Full load Partial load Requirement
Test fuel Pellets
Mass of the test fuel fired hourly kg/h 4,75 1,19 -
Flue gas mass flow g/s 11,7 5,0 -
Flue gas temperature °C 145,5 69,9 -
Flue draught mbar 0,12 0,12 0,12/0,10 +/-0,02
CO2-concentration Vol.-% 14,22 7,91 -
O2-concentration Vol.-% 6,04 12,61 -
CO-concentration ppm 120,2 102,2 -
CO-emission (at 13%-O2) mg/m³ 80,2 121,8 500/750 EN
CO-emission mg/kWh 192,5 289,4 -
CO-emission mg/MJ 53,5 80,4 500/750 (Art. 15a)
NOx-concentration ppm 129,4 78,1 -
NOx-emission (at 13%-O2) mg/m³ 141,8 152,6 -
NOx-emission mg/kWh 340,1 362,7 -
NOx-emission mg/MJ 94,5 100,7 100 (Art. 15a)
CnHm-concentration measured acc. CEN/TS 15883 mg/m³ 1,8 0,7 -
CnHm-emission (at 13%-O2) mg/m³ 1,6 1,1 -
CnHm-emission mg/kWh 3,8 2,6 -
CnHm-emission mg/MJ 1,1 0,7 30/30 (Art. 15a)
Dust concentration
measured acc. CEN/TS 15883 and EN13284-1 mg 5,7 1,3 -
Dust emission (at 13%-O2) mg/m³ 11,9 4,3 -
Dust emission mg/kWh 28,6 10,2 -
Dust emission mg/MJ 7,9 2,8 25 (Art.15a)
Particulate emission
acc. PrEN16510:2012 mg/m³ 12,3 4,7 -
Total heat output kW 21,20 5,50 -
Water heat output kW 18,10 4,82 -
Space heat output kW 3,10 0,68 -
Efficiency % 92,88 95,28 75/70 (EN14785)
80 (Art. 15a)
Maximum temperatures at trihedron:
- Right side - Back side - Front side 100 cm - Floor
°C °C °C °C
57,3 34,8 46,1 43,1
65K over tambient 65K over tambient 65K over tambient
Distances: - Backside-Pelletstove - Side-Pelletstove Ambient temperature Temp. in fuel hopper Temp. operating tools (handle of cleaning system)
mm mm °C °C °C
200 200 22
53,7 95,6*
65K over tambient
65K over tambient 35K over tambient
*) A suitable glove is part of the appliance and is supplied by the manufacturer
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 6 / 7 Report no. K 2022 2017 Z1
3 Statement of the test results
The appliance
BIOPELLET 18
BIOPELLET 18 PLUS
TERMO ORIONE PLUS
Trademark: FERROLI
TERMO FOCUS PLUS acciaio
Trademark: ANSELMO COLA
of the company
COLA S.r.l.
complies for the operation with wood pellets with the requirements acc. DIN EN 14785: September
2006, cl.4-8.
The results of the basic initial type test (see report K 1570 2015 T1 and K 1570 2016 E6) are not
affected by the renaming.
The electrical safety cl. 5.9. of the standard was not a part of this initial type testing.
The presumption of conformity with the relevant European Directives respectively Regulations
could only be confirmed by full compliance with Annex ZA.
The test results presented in this report refer solely to the test object stated as described on page
2. The report does not represent a general statement about the serial production of the test object
and gives not an authorization for use of a TÜV Rheinland test- / certification mark.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 7 / 7 Report no. K 2022 2017 Z1
4 Test documents
Appendix Subject Reference
A01 Type labels 2017
A02 EU Declaration of Conformity 13.03.2017
A03 Declarations of Performances 13.03.2017
A04 Declaration of Extension 13.03.2017
A05 Manual BIOPELLET 18 06/2017
A06 Manual BIOPELLET 18 PLUS 06/2017
A07 Manual TERMO FOCUS PLUS 06/2017
A08 Manual TERMO ORIONE PLUS 06/2017
A09 CE marking information 2017
A10 Drawings 31.01.2017
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
TÜV Rheinland Energy GmbH
Am Grauen Stein D-51105 Köln
Managing Director: Amtsgericht Köln HRB 56171
Telefon: Telefax:
02 21 / 8 06 – 52 00 02 21 / 8 06 – 13 49
Dirk Fenske K 2004 2017 Z1.docx
Report No. K 2004 2017 Z1
Supplement test report -Renaming-
Residential space heating appliances
acc. DIN EN 14785
Model: BIOPELLET 24
BIOPELLET 24 PLUS SOLAR PLUS 23
Trademark: FERROLI
ANSELMO COLA
Company: COLA S.r.l.
2017
This report may only be published and forwarded to third parties in its complete, unabridged form. The publication or dissemination of extracts, summaries, appraisals or any other adaptation and alterations, in particular for advertising
purposes, is only permissible with the prior written permission of TÜV Rheinland. Publication of page 2 is permitted.
The test results presented in this report refer solely to the test object stated as described on page 2. The report does not
represent a general statement about the serial production of the test object and gives not an authorization for use of a TÜV Rheinland test- / certification mark.
This accreditation is valid only for the listed standards as stated in the accreditation annex of D-PL-11120-04-00.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239058 Seite 2 / 7 Report no. K 2004 2017 Z1
Supplement test report -Renaming-
Residential space heating appliances fired by wood pellets DIN EN 14785: September 2006
Correction 1 DIN EN 14785: 10/2007
Applicant/contractor: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy
Trademark: FERROLI, ANSELMO COLA
Type of appliance: Residential room heating appliances fired by wood pellets with water heat exchanger, with fan assisted flue discharge and with internal fuel hopper
Model designation: BIOPELLET 24 BIOPELLET 24 PLUS SOLAR PLUS 23
Total heat input [kW]: 7,2 – 24,6
Water heat output [kW]: 6,0 – 21,1
Space heat output [kW]: 0,9 – 1,9
Max. water pressure: 2,0 bar
Max. water temperature: 80,0 °C
Fuels: Wood pellets (Ø 6mm, Lmax 30 mm, max humidty 5,6%, Pfeifer)
Type of fuel charging: Automatic load
Remarks: The results of the basic initial type test (see report K 1573 2015 T1) are not affected by the renaming.
Test results: The technical requirements cl. 4-8 of the above mentioned standard are fulfilled. The local applicable installation conditions are to be observed. The electrical safety cl. 5.9. of the standard was not a part of this initial type testing. The presumption of conformity with the relevant European Directives respectively Regulations could only be confirmed by full compliance with Annex ZA.
Cologne, 27.07.2017 432/mh
Test Centre according to Construction Product Regulation 305/2011(CPR) Notified Body: 2456
Assessor: Report released after review:
M.Sc. M. Höfinghoff Dipl.-Ing. A. Pomp
Residential space heating appliances fired by wood pellets, Initial Type Test in accordance with the regulation 305/2011
conformity certification system no. 3
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239058 Seite 3 / 7 Report no. K 2004 2017 Z1
1 Task
The Test Centre for Energy Appliances was instructed to execute an renaming on the above
mentioned pellet stoves.
Basic: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy Report K 1573 2015 T1
New: Cola S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) - Italy Report K 2004 2017 Z1
Trademark: COLA
Trademark: COLA
Trademark: ANSELMO COLA
Model: AQUAPLUS 23
Model: BIOPELLET 24 BIOPELLET 24 PLUS
Model: SOLAR PLUS 23
2 Testing
The practical tests were carried out in the laboratory in Thiene dated on the 7th and 8th April 2015.
The stove AQUAPLUS 23 by Cola S.r.l. was tested (report K 1573 2015 T1). Cola S.r.l. ensures
that modifications on the above mentioned products were not carried out.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239058 Seite 4 / 7 Report no. K 2004 2017 Z1
2.1 Resume of test results
BIOPELLET 24 BIOPELLET 24 PLUS SOLAR PLUS 23
Nominal Partial Requirement
Mass of the test fuel fired hourly kg/h 5,1 1,5 -
Flue gas mass flow g/s 11,3 6,0 -
Flue gas temperature °C 146,95 80,30 -
Flue draught mbar 0,12 0,12 0,12/0,10 +/-0,02
CO2-concentration Vol.-% 15,8 8,3 -
O2-concentration Vol.-% 4,2 12,2 -
CO-concentration ppm 215 60 -
CO-emission (at 13%-O2) mg/m³ 128,0 68,0 500/750
CO-emission mg/kWh 304,1 161,6 -
CO-emission mg/MJ 84,5 44,9 500/500 (Art. 15a)
NOx-concentration ppm 154 93 -
NOx-emission (at 13%-O2) mg/m³ 151,1 173,7 -
NOx-emission mg/kWh 358,9 412,8 -
NOx-emission mg/MJ 99,7 114,7 100/- (Art. 15a)
CnHm-concentration measured acc. CEN/TS 15883
mg/m³ 0,4 0,5 -
CnHm-emission (at 13%-O2) mg/m³ 0,3 0,7 -
CnHm-emission mg/kWh 0,8 1,8 -
CnHm-emission mg/MJ 0,2 0,5 30/30 (Art. 15a)
Dust concentration measured acc. CEN/TS 15883 and EN13284-1
mg 4,2 1,7 -
Dust emission (at 13%-O2) mg/m³ 7,5 5,4 -
Dust emission mg/kWh 17,9 12,7 -
Dust emission mg/MJ 5,0 3,5 25/- (Art.15a)
Particulate emission acc. PrEN16510:2012
mg/m³ 7,6 5,7 -
Total heat output kW 23,0 6,8 -
Water heat output kW 21,1 6,0 -
Space heat output kW 1,9 0,9 -
Efficiency % 93,4 94,8 75/70 (EN14785) -
80(Art. 15a)
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239058 Seite 5 / 7 Report no. K 2004 2017 Z1
2.2 Temperatures
BIOPELLET 24 BIOPELLET 24 PLUS SOLAR PLUS 23
Maximum temperatures
at trihedron:
- Left side °C 33,8 65 K over tambient
- Back side °C 32,2 65 K over tambient
- Floor °C 25,6 65 K over tambient
- Front °C 22,8 65 K over tambient
Distances:
- Backside-Pelletstove mm 100
- Side-Pelletstove mm 100
- Frontside-Pelletstove mm 700
Ambient temperature °C 21,4
Max. temperature in fuel hopper °C 73,9 65 K over tambient
Max. temperature of operating tools °C 151,4* 60 K over tambient Detailed test results see test report K 1573 2015 T1.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239058 Seite 6 / 7 Report no. K 2004 2017 Z1
3 Statement of the test results
The appliances
BIOPELLET 24 BIOPELLET 24 PLUS Trademark: FERROLI
SOLAR PLUS 23 Trademark: ANSELMO COLA
of the company
COLA S.r.l. complies for the operation with wood pellets with the requirements acc. DIN EN 14785: September 2006, cl.4-8. The results of the basic initial type test (see report K 1573 2015 T1) are not affected by the renaming. The electrical safety cl. 5.9. of the standard was not a part of this initial type testing. The presumption of conformity with the relevant European Directives respectively Regulations could only be confirmed by full compliance with Annex ZA. The test results presented in this report refer solely to the test object stated as described on page 2. The report does not represent a general statement about the serial production of the test object and gives not an authorization for use of a TÜV Rheinland test- / certification mark.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239058 Seite 7 / 7 Report no. K 2004 2017 Z1
4 Test documents
Appendix Subject Reference
A01 Type labels 2017
A02 Declaration of Conformity 26.01.2017
A03 Declaration of Performances 26.01.2017
A04 Declaration of Extension 13.03.2017
A05 Instruction manual BIOPELLET 24 01/17
A06 Instruction manual BIOPELLET 24 PLUS 01/17
A07 Instruction manual SOLAR PLUS 23 06/17
A08 Component list 18.07.2017
A09 Drawing BIOPELLET 24 31.07.2017
A10 Drawing BIOPELLET 24 PLUS 31.07.2017
A11 Drawing SOLAR PLUS 23 10.05.2017
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
TÜV Rheinland Energy GmbH
Am Grauen Stein D-51105 Köln
Managing Director: Amtsgericht Köln HRB 56171
Telefon: Telefax:
02 21 / 8 06 - 52 00 02 21 / 8 06 – 13 49
Dirk Fenske K 2023 2017 Z1.docx
Report No. K 2023 2017 Z1 Heating boilers for solid fuels
Type testing in accordance with EN 303-5:2012
-renaming-
Model: BIOPELLET 29; EASYFIRE 29 BIOPELLET 35; EASYFIRE 35 BIOPELLET 39; EASYFIRE 39
Trademark:
Ferroli
Company: COLA S.r.l.
This report may only be published and forwarded to third parties in its complete, unabridged form. The publication or dissemination of extracts, summaries, appraisals or any other adaptation and alterations, in particular for advertising
purposes, is only permissible with the prior written permission of TÜV Rheinland. Publication of page 2 is permitted.
The test results presented in this report refer solely to the test object stated as described on page 2. The report does not
represent a general statement about the serial production of the test object and gives not an authorization for use of a TÜV Rheinland test- / certification mark.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 2 / 9 Report no. K 2023 2017 Z1
Type testing Heating boilers for solid fuels acc. DIN EN 303-5: October 2012
Test of the heating requirements
Applicant/contractor: COLA S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR)
Trademark: Ferroli
Type of construction: Heating boiler in accordance with EN303-5
Type of loading: automatic load
Model designation: BIOPELLET 29 EASYFIRE 29
BIOPELLET 35 EASYFIRE 35
BIOPELLET 39 EASYFIRE 39
Total heat input [kW]: 6,4 – 29,0 6,4 – 34,4 6,4 – 38,3
Total heat output [kW]: 5,8 - 27,4 5,8 - 32,4 5,8 - 34,9
Max. working temperature: 80 °C
Max. working pressure: 3 bar
Type of fuel: Wood pellets, 6 mm, Lmax 30 mm, max. humidity 4,7%, Pfeifer
Test basis: According EN 303-5:2012, 4.4 Heating requirements. This examination has been carried out by the impartial test centre of TÜV Rheinland in a test laboratory equipped in accordance with DIN EN 304, version 01/04.
Test results: The boiler are in conformity to the emission class 5, EN 303-5:2012, cl. 4.4.7 and the efficiency class 5, EN 303-5:2012, cl. 4.4.2. The clauses 4.3.9.2 electrical safety and 4.3.9.3 electromagnetic compatibility were not tested. The requirements of the above-mentioned standards are fulfilled. The local, applicable installation conditions to be observed. Additional details are documented in the initial reports K 855 2012 T1 /T2 and K 970 2013 Z1.
Remarks: The main difference between Biopellet and Easyfire Series is the pump circulator. On the Biopellet models, the pump circulator is mounted on board. On the Easyfire models, the pump circulator is mounted directly on the hydraulic plant. For more information see Basic report K 855 2012 T1 / T2.
Cologne, 2017-06-22 432 / mc
Test Centre for Energy Appliances DIN- und DVGW-Laboratory
Assessor: Report released after review:
Dipl.-Ing. M. Ciccarelli Dipl.-Ing. A. Pomp
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 3 / 9 Report no. K 2023 2017 Z1
1. Task
The Test Centre for Energy Appliances was instructed to execute an renaming on the above mentioned pellet stoves.
Basic: COLA S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) Report K 855 2012 T1/T2
New: COLA S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) Report K 970 2013 Z1
New: COLA S.r.l. Viale del Lavoro, 7/9 37040 Arcole (VR) Report K 2023 2017 Z1
Trademark: Cola
Trademark: Cola
Trademark: Ferroli
DomusFire C29 DomusFire C35 DomusFire C38
Domus Fire C 39
BIOPELLET 29; EASYFIRE 29 BIOPELLET 35; EASYFIRE 35 BIOPELLET 39; EASYFIRE 39
2. Testing
The practical tests were carried out in the laboratory in Thiene dated August and November 2012. The boilers DomusFire C29, DomusFire C35 and DomusFire C39 were tested by Cola S.r.l. was tested (report K 855 2012T1). Cola S.r.l. ensures that modifications on the above mentioned products were not carried out.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 4 / 9 Report no. K 2023 2017 Z1
2.1 Test results at maximum load
BIOPELLET 29; EASYFIRE 29* required achieved
Type of fuel wood pellets
Nominal heat input kW 29,0 29,0
Nominal heat output kW 27,4 27,4
Duration of combustion s ≥ 21600 21600
Mean flow temperature °C 70 - 90 78,3
Boiler efficiency (direct method) Efficiency class
% ≥ 88,5
Class 5 acc. DIN EN 303-5
94,5
Flue gas pressure Pa 12 ± 2 12,0
Flue gas temperature °C ≥ 160 + room temperature 134,3 **
Room temperature °C 15 - 30 29,8
O2-Concentration Vol-% - 5,7
CO-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 500
Class 5 acc. DIN EN 303-5
61,0
CO-Emission Emission class (Referring to 13 Vol. % O2, dry)
mg/m3 - 44,4
OGC-Emission (CxHy) (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 20
Class 5 acc. DIN EN 303-5
6,7
OGC-Emission (CxHy) (Referring to 13 Vol. % O2, dry) Emission class
mg/m³ - 4,9
Dust-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 40
Class 5 acc. DIN EN 303-5
24,1
Dust-Emission (Referring to 13 Vol. % O2, dry) Emission class
mg/m3 - 17,6
*) Data´s are linear interpolated **) Flue gas temperature below 160 K room temperature. See the recommendations regarding the flue installation in the manual.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 5 / 9 Report no. K 2023 2017 Z1
BIOPELLET 35; EASYFIRE 35 required achieved
Type of fuel wood pellets
Nominal heat input kW 34,4 34,4
Nominal heat output kW 32,4 32,4
Duration of combustion s 21600 21600
Mean flow temperature °C 70 ÷ 90 79,4
Boiler efficiency (direct method) Efficiency class
% ≥ 88,3
Class 5 acc. DIN EN 303-5
94,2
Flue gas pressure Pa 12 ± 2 12,0
Flue gas temperature °C ≥ 160 + room temperature 148,6 **
Room temperature °C 15 - 30 29,7
O2-Concentration Vol-% - 5,3
CO-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 500
Class 5 acc. DIN EN 303-5
83,0
CO-Emission Emission class (Referring to 13 Vol. % O2, dry)
mg/m3 - 60,4
OGC-Emission (CxHy) (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 20
Class 5 acc. DIN EN 303-5
6,6
OGC-Emission (CxHy) (Referring to 13 Vol. % O2, dry) Emission class
mg/m³ - 4,8
Dust-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 40
Class 5 acc. DIN EN 303-5
23,6
Dust-Emission (Referring to 13 Vol. % O2, dry) Emission class
mg/m3 - 17,2
**) Flue gas temperature below 160 K room temperature. See the recommendations regarding the flue installation in the manual.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 6 / 9 Report no. K 2023 2017 Z1
BIOPELLET 39; EASYFIRE 39 required achieved
Type of fuel wood pellets
Nominal heat input kW 38,3 38,3
Nominal heat output kW 34,9 34,9
Duration of combustion s 21600 21600
Mean flow temperature °C 70 ÷ 90 76,5
Boiler efficiency (direct method) Efficiency class
% ≥ 88,5
Class 5 acc. DIN EN 303-5
91,3
Flue gas pressure Pa 12 ± 2 12,0
Flue gas temperature °C ≥ 160 + room temperature 159,5 **
Room temperature °C 15 - 30 19,4
O2-Concentration Vol-% - 5,4
CO-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 500
Class 5 acc. DIN EN 303-5
106,8
CO-Emission Emission class (Referring to 13 Vol. % O2, dry)
mg/m3 - 77,7
OGC-Emission (CxHy) (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 20
Class 5 acc. DIN EN 303-5
6,7
OGC-Emission (CxHy) (Referring to 13 Vol. % O2, dry) Emission class
mg/m³ - 4,9
Dust-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 40
Class 5 acc. DIN EN 303-5
24,5
Dust-Emission (Referring to 13 Vol. % O2, dry) Emission class
mg/m3 - 17,8
**) Flue gas temperature below 160 K room temperature. See the recommendations regarding the flue installation in the manual.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 7 / 9 Report no. K 2023 2017 Z1
2.2 Test results at minimum load
BIOPELLET 29; EASYFIRE 29 BIOPELLET 35; EASYFIRE 35 BIOPELLET 39; EASYFIRE 39
required achieved
Type of fuel wood pellets
Nominal heat input kW 6,4 6,4
Nominal heat output kW 5,8 5,8
Duration of combustion s 21600 21600
Mean flow temperature °C 70 ÷ 90 80,5
Boiler efficiency (direct method) Efficiency class
% ≥ 88,3
Class 5 acc. DIN EN 303-5
90,1
Flue gas pressure Pa 12 ± 2 10,0
Flue gas temperature °C - 62,6
Room temperature °C 15 - 30 29,7
O2-Concentration Vol-% - 12,7
CO-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 500
Class 5 acc. DIN EN 303-5
376,0
CO-Emission Emission class (Referring to 13 Vol. % O2, dry)
mg/m3 - 362,0
OGC-Emission (CxHy) (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 20
Class 5 acc. DIN EN 303-5
18,8
OGC-Emission (CxHy) (Referring to 13 Vol. % O2, dry) Emission class
mg/m³ - 13,7
Dust-Emission (Referring to 10 Vol. % O2, dry) Emission class
mg/m3 ≤ 40
Class 5 acc. DIN EN 303-5
9,5
Dust-Emission (Referring to 13 Vol. % O2, dry) Emission class
mg/m3 - 6,9
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 8 / 9 Report no. K 2023 2017 Z1
3. Statement of the test results
The solid fuel boilers
BIOPELLET 29; EASYFIRE 29 BIOPELLET 35; EASYFIRE 35 BIOPELLET 39; EASYFIRE 39
and trademark:
Ferroli of the company
Cola S.r.l complies the requirements of the standards acc. DIN EN 303-5: October 2012. The clauses
cl. 4.1 Parts of electrical accessories have to fulfil the requirements of resistance against heat and fire acc. EN 60335-1 or EN 60730-1.
cl. 4.3.9.2 electrical safety
cl. 4.3.9.3 electromagnetic compatibility are not tested. The results of the basic type testing (see report K 855 2012 T1 / K 855 2012 T2) are not affected by the renaming. This statement was given based on the documentation submitted by the manufacturer and the tested sample. The statement is valid only for products / appliances which are manufactured according to the tested specimen.
TÜV Rheinland Energy GmbH
Test Centre for Energy Appliances
Order no. 432-21239552 Seite 9 / 9 Report no. K 2023 2017 Z1
4 Test documents
Appendix Subject Reference
A01 Type labels
A02 Declarations of conformity 13/03/2017
A03 CE marking information’s ---
A04 Declarations of equivalence 27/04/2017
A05 List of electrical components 27/05/2017
A06 User and installations manual 48427E012-M4
A07 User and installations manual 48427B012_IT_DE
A08 Drawing Biopellet 31/01/2017
A09 Drawing Easyfire 20/04/2017
A10 Overwiew drawing Biopelett 31/01/2017
A11 Overwiew drawing Easyfire 19/05/2017