®TO High Pressure Sodium - WESCO International · 2014-01-15 · ®TO High Pressure Sodium >-*...
Transcript of ®TO High Pressure Sodium - WESCO International · 2014-01-15 · ®TO High Pressure Sodium >-*...
HIGH INTENSITY DISCHARGE BALLASTS
Core & Coil Ballasts(60 Hz., Minimum Starting Temperature -40°F or-40°C)
®TO High Pressure Sodium
>-
*
InputVolts
Catalog"!"Number
CircuitType
WattsInput
Max*Input
Current
NornOpen
CircuitVoltage
FuseRating(Amps)
WiringDie
Dimensions
FIO A B
Non-PCB Capacitor(Page 4-48 to 4-49)
MM MinVolt
Dry Film
Dia(in)
HI(in)
OH Filled
Oval(In)
Ht(in)
TotalWeight
(IDS)
Ignitortt(Page 4-50 to 4-53)
PartNumber
DMTo
Lamp(ft)
U.L.BenchTopRiseCode1029(PB«)
250 Watt Lamp, ANSI Code S50120
127/220277
480
480/1 20T
120/277
120/208/240/277
120/208/240/277
120/208/240/277/
480
120/
277/347
120/
277/347
120/
208/240
120/240
240/480
120/277
71A8201
71A82H171A8231
71A824171A8241-001D
71A8241-T
71A8281
71A8291
71A8Z71-001D
71A825171A82S1-001D
71A82A1
71A82A1-001D
71A82E6
71A8250
71A8260
71A8280
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWA
CWI
RegulatedLag
RegulatedLag
RegulatedLag
295
310
310
295
295
295
300
295
295
300
310
310
310
2.5
2.5/1.51.1
.7
.7
2.5/1.1
2.5/1 .5/1.3/1.1
2.5/1 511.3/1.1
2.6/1 .5/1.3/1 .27
.7
2.7/
1.2/.9
2^7?1.2/.9
2.8/
1.6/1.4
2.7/1.4
1.4/.7
2.7/1.2
185
185
185
185
185
185
185
185
185
190
220
220
220
7
7/4
3
2
2
7/3
"7>4/"
4/3
7/4/
4/3
10/4/4/3/
2
113/2
113/2
8/5/5
8/4
4/2
8/3
M
M
M
M
M
M
M
M
M
V
N
N
N
2
2
2
2
2
2
2
2
2
2
3
3
3
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
1.9
2.4
2.4
2.4
3.5
3.5
3.5
3.5
3.5
3.5
3.6
3.6
3.6
3.8
4.0
4.0
4.0
35
35
35
35
35
35
35
35
35
28
16
16
16
240
240
240
240
240
240
240
240
240
300
480
480
480
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
—
—
—
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
—
—
—
—
—
—
—
—
—
—
—
1.75
1.75
1.75
—
—
I—
—
—
—
—
3.90
3.90
3.90
11.0
11.0
11.0
11.0
11.0
11.0
12.0
11.5
11.5
11.0
18.0
18.0
18.0
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-J4
LI501-H4
LI501-H4
LI501-H4
2
2
2
2
2
2
2
2
2
2
2
2
2
A
D/C
B
B
B
B/B
B/A/
B/B
B/A/
B/B
B/B/
B/B/
B
C/C/B
C/C/B
D/C/C
C/C
C/C
C/C
t Ordering information:Replacement/retrofit ballast kits indicated by bold type with suffix -001 D.Refer to pages 4-5 to 4-9.Original equipment ballasts - add proper suffix to catalog number:
-500D includes core & coil with dry-film capacitor-510D includes core & coil with welded bracket and dry-film capacitor-600 core & coil only (no capacitor)-610 core & coil with welded bracket (no capacitor)
• For CWA circuits, figure is operating current.ttEach ballast requiring an ignitor is furnished as standard with the Short
Range ignitor model shown for use within fixtures. If a Long Range ignitoris required for remote mounting, specify on order. See pages 4-50 to 4-53for additional information.
* Canadian replacement/retrofit ballast kit indicated by bold type.Refer to pages 4-11 to 4-12.
XX.ADVANCE A D V A N C E , 1 0 2 7 5 W E S T H I G G I N S R O A D , R O S E M O N T , IL 6 0 0 1 8 . T E L : ( 8 4 7 ) 3 9 0 - 5 0 0 0 , F A X : ( 8 4 7 ) 3 9 0 - 5 1 0 9 4-41
HIGH INTENSITY DISCHARGE BALLASTS
Encapsulated Core & CoilWhere quiet performance is required, the standard open core & coil bal-lasts are encapsulated (potted) in a cube-shaped steel can utilizingClass H (180°C) polyester compound. These ballasts carry a Class Anoise rating up through 175 watts and Class B for 250 and 400 watts.As with the open core & coil, the capacitor (and ignitor where included)are mounted separately within the fixture.Fluorescent Can (F-Can)For indoor commercial applications of HID lighting such as offices,schools and retail stores, ballast noise must be minimized. Ballasts forthese fixtures are most often encased and potted in fluorescent ballasttype cans and utilize Class A (90°C) asphalt insulating materials (thesame as used in fluorescent lamp ballasts).
The Advance line of F-can ballasts comes in two dual-voltage con-figurations: 120/277 volt for the US market, and 120/347 volt for theCanadian market. Each unit has built-in, automatically resetting, ther-mal protectors which disconnect the ballast from the power line in theevent of overheating. All units are high power factor and include thecapacitor within the can. All models for high pressure sodium, low-wattage metal halide, and pulse-start metal halide lamps also includethe ignitor in the can.Indoor EnclosedThese units are designed for use indoors where the ballast must bemounted remotely from the luminaire. They are most typically used infactories where the luminaire may be mounted in a high-bay where veryhigh ambient temperatures may be experienced. In these instances, theremotely-mounted ballast operates cooler, subsequently providinglonger life because it is away from both the heat of the ceiling ambientand lamp heat within the fixture.
The case contains the core & coil potted in a Class H (180°C) heat-dissipating resin. The capacitor(s) and ignitor are contained within aseparate compartment. Knockouts in both ends of the case facilitatehook-up in the most convenient manner. Wall mounting is accom-plished through flanges on the top and bottom of the case. The ballastis a UL Listed product.Outdoor WeatherproofWeatherproof ballasts are designed for remote, pole-mounting outdoorapplications under all weather conditions. They may also be placedinside of a transformer pole base, but care must be taken to avoid areasprone to flooding because weatherproof ballasts are not water-sub-mersible.
The core & coil with its capacitor and ignitor (where required) arefirmly mounted to the heat-sink base. An aluminum cover is placed overthe core-&-coil assembly and is bolted with a weather-tight gasket tothe base. An integral 1" threaded nipple with locknut facilities hook-upto electrical conduit or to the mounting bracket when used on a pole.The weatherproof ballast may also be placed nipple-up, with a drip loopin the leads, inside a pole base.PostlineLantern-type fixtures mounted on slender poles often require ballastswhich will fit into these poles. Special, elongated core & coil ballasts arepotted in resin in cylindrical cans having a 2.55" outside diameter. Allinclude leads necessary for direct connection to a photocell.
The capacitor and ignitor (where required) are included within thiscan. A 1/2" threaded nipple is used for vertical mounting, and leadsextend from both ends of the can for ease of installation. The inputleads to the ballast also provide for proper connection to the photocellif such is included within the fixture.
To help prevent overheating, one to three feet of air space should beallowed in the pole above the ballast, and the ballast should be posi-tioned against the post interior wall to provide a heat-sink. All unitsrated 100W and above now include a mounting kit consisting of an 18"chain to hang the ballast within the pole and a spring clip to force theballast's cylindrical can to make line contact with the pole's interiorsurface to maximize heat transfer, thus prolonging the ballast life.
BALLAST DATE AND TEMPERATURE CODES
Ballast Label^Catalog Number
TemperatureCode
Date CodeStamp
Alternate Positions forDate Stamp Code
ADVANCE 9 HID Core & Coil ballasts are date stamped on either the topsurface or the side surface of the ballast core. The four-digit number rep-resents the week and year of manufacture. The first two numbers indi-cate the week and the last two indicate the year the ballast was manu-factured. The example shows a ballast manufactured during the 36thweek of 1989. The three letters are an Advance factory code.The ballast's UL Bench Top Rise Temperature Code is shown on the label(see below).
UL BENCH TOP RISE TEMPERATURE CODETo facilitate UL inspection, each ballast's UL Bench Top RiseTemperature Code is shown on the Advance Core & Coil ballast label as1029X, where 1029 is the UL Standard for HID Ballasts, and the X is thetemperature code: A, B, C, etc. If a fixture is UL listed for 1029C, thenautomatically, all ballasts with an A, B, or C temperature classificationare acceptable for use within that same fixture.
UL Bench Top RiseLetter Code
A
B
C
D
E
F
etc.
Temperature Range for Temperature Range forClass H (180°C) Ballasts Class N (200°C) Ballasts
less than 75°C
75°C < 80°C
80°C < 85°C
85°C < 90°C
90°C < 95°C
95°C<100°C
etc.
less than 95°C
95°C<100°C
100°C<105°C
105°C<110°C
1100C<115°C
115°C<120°C
etc.
CERTIFICATIONSIndicates ballast is listed by Underwriters Laboratories,
Inc. in accordance with UL 1029 Standard for HID Ballasts.Each ballast is marked appropriately.
Indicates ballast is component recognized by UnderwritersLaboratories, Inc. in accordance with UL 1029 Standard forHID Ballasts. Each ballast is marked appropriately.
Indicates ballast is certified by Canadian StandardsAssociation in accordance with CAIM/CSA-22.2 No. 74-92.Each ballast is marked appropriately.
All HID Ballasts are designed and manufactured inaccordance with the American National StandardsInstitute Standard for HID Ballasts, ANSI C82.4.
Xk ADVANCE A D V A N C E . 1 0 2 7 5 W E S T H I G G I N S R O A D , R O S E M O N T , IL 6 0 0 1 8 . T E L : ( 8 4 7 ) 3 9 0 - 5 0 0 0 , F A X : ( 8 4 7 ) 3 9 0 - 5 1 0 9
HIGH INTENSITY DISCHARGE BALLASTS
ORDERING INFORMATIONHow to Order
Advance Transformer has developed the industry's broadest selection of HID ballasts. More than 3000 stocking distributorsnationwide. For information on the distributor best able to serve your needs, please call 800-372-3331 .
Advance HID Ballast Part Number Explanation
71 A 60 9 1 -500D
Suffix Code*(as applicable)
-001 D ballast replacement kit with dry film capacitor-001 ballast replacement kit with oil filled capacitor-500D core & coil ballast with dry film capacitor-500 core & coil ballast with oil filled capacitor-510D core & coil ballast with welded bracket and dry film capacitor-510 core & coil ballast with welded bracket and oil filled capacitor-540D core & coil ballast with welded angle bracket and dry film capacitor-600 core & coil ballast (no capacitor)-610 core & coil ballast with welded bracket (no capacitor)
* Add additional feature codes to the end of suffix where applicable.i.e. -B = Integral Ignitor, -P = Thermally Protected, -J = J-Box Mounting
Design Code
60 Hz Voltages 50 HZ Voltages
0 = 120VINPUT 1 = 208V
VOLTAGE 2 = 240VCODE 3 = 277V
4 = 480V5 = 120/240Vor
A = 120/277/347V NU100/200VB- 347V N= 120/220-240VC= 120/347V R = 220/240V
D= 120/240/347VE= 120/208/240Vor208/240VF = 277/480V, 277/347V, 277/347/480V or
120/208/240/277/480V 347/480V6 = 240/480V7 = 120/208/240/277V8 = 120/277V9 = 120/208/240/277V
H= 127/220VJ= 220V or 220/240VY = 100Vor100/200V
Lamp Type/Wattage/Ballast Circuit Code
71A = Core and Coil Ballast
Rallact 72C = F-CanBallast
Danasi 73B = Encapsulated Core and Coil BallastType 74P = Postline Ballast
77K = Val-U-Pak Replacement Ballast Kit77L = Val-U-Pak Plus Replacement Ballast kit (includes lamp)78E = Indoor Enclosed Ballast79W = Outdoor Weatherproof Ballast
4-4 AADVANCE A D V A N C E , 1 0 2 7 5 W E S T H I G G I N S R O A D , R O S E M O N T , IL 6 0 0 1 8 . T E L : ( 8 4 7 ) 3 9 0 - 5 0 0 0 , F A X : ( 8 4 7 ) 3 9 0 - 5 1 0 9
HIGH INTENSITY DISCHARGE BALLASTS
Core & Coil Ballasts(60 Hz., Minimum Starting Temperature -40°F or-40°C)
1iSpI7^righ Pressure Sodium @.SII
InputVolts
Catalog tNumber
CircuitType
WattsInput
Max*Input
Current
NornOpen
CircuitVoltage
FuseRating(Amps)
WiringDia
Dimensions
FiQ A B
Non-RGB Capacitor(Page 4-48 to 4-49)
MM MinVolt
Dry Film
Dla(in)
Ht(in)
Oil Filled
Oval(in)
Ht(in)
TotalWeight(IDs)
Ignitor ft(Page 4-50 to 4-53)
PartNumber
MaxDistTo
Lamp
(ft)
U.LBenchTopRiseCode1029(M«)
200 Watt Lamp, ANSI Code S66
480
120/208/240/277
120/208/240/277
480
120/208/240/277
120/240
240/480
71A894071A8940-001D
71A8990
71A8970-001D
71A8941*
71A8991*
71A8954
71A8964
CWA
CWA
CWA
CWA
CWA
RegulatedLag
RegulatedLag
240
240
240
250
250
255
255
.6
2.2/1.31.1/1.0
2.2/1.31.1/1.0
.6
2.4/1.41.2/1.0
2.2/1.1
1.1/.7
185
185
185
195
195
225
225
2
6/4/3/3
6/4/3/3
2
8/5/5/3
6/3
3/2
M
M
M
M
M
N
l\l
2
2
2
1
1
2
2
1.2
1.2
1.2
3.0
3.0
2.3
2.3
3.0
3.0
3.0
4.2
4.2
3.9
3.9
28
28
28
24
24
18
18
280
280
280
280
280
400
400
1.75
1.75
1.75
1.75
1.75
1.75
1.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
—
t Ordering information:Replacement/retrofit ballast kits indicated by bold type with suffix -001 D.Refer to pages 4-5 to 4-9.Original equipment ballasts - add proper suffix to catalog number:
-500D includes core & coil with dry-film capacitor-510D includes core & coil with welded bracket and dry-film capacitor-600 core & coil only (no capacitor)-610 core & coil with welded bracket (no capacitor) <
• For CWA and Regulated Lag circuits, figure is operating current.ttEach ballast reouirina an ianitor is furnished as standard with the Short Rarme ionitor model shown for
\
;••
\
f>
—
—
—
:x>jg<C
1&fe
8.5
8.5
8.5
8:5
8.5
14.0
14.0
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
LI501-H4
2
2
2
2
2
2
2
C
E/D/D/C
E/D/D/C
J
H/G/H/l
C
C
•̂J ^_^Ji Holes cleared lor] , /^ MO Thru-bolls
X^k
M̂9^y"^-""' R n S
use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order. Seepages 4-50 to 4-53 for additional information.
* Special compact 3 x 4 core design. Note Bench Top Rise Codes in last column.
^~f
Fig. N
Fig.M
Fig. 2(4 ' /4"x4 a /4"core)
IPBracket <?k A
WELDED BRACKET DIMENSIONS
BallastDimensions Fig
12
3
L
5.1
6.5
7.8
W
1.00
1.25
2.75
M
4.50
5.75
6.13
S
0.25
0.28
0.25
4-40 XV ADVANCE A D V A N C E , 1 0 2 7 5 W E S T H I G G I N S R O A D , R O S E M O N T , IL 6 0 0 1 8 . T E L : ( 8 4 7 ) 3 9 0 - 5 0 0 0 , F A X : ( 8 4 7 ) 3 9 0 - 5 1 0 9