TMS Silent Clips - A237R · 2016. 9. 19. · TMS Silent Clips - A237R Installation Instructions...

4
www.TMSoundproofing.com TMS Silent Clips - A237R Installation Instructions A237R Specifications: Width: 1.375” Height: 3.25” Depth: 1.125” Weight: 0.25 Lbs Max spacing between clips: 48” OC Max load: 36 Lbs. Furring Channel Specifications: Minimum: 25 Gauge with hemmed edge Depth: 7/8” or 1-1/2” Width at top: 1-1/4” Width at bottom: 2-1/2” * When splicing hat channel, overlap 6 inches in between two A237R clips. Secure the channel with two 7/16” framing screws or 18 Gauge tie wire can be used. * Available at your local building supply stores Fasteners: A. Wood: # 8 x 2-1/2” Coarse Threads B. Steel: #8, #10 or #12 x 1- 5/8” Self Tapping Type S C. Concrete: 3/16” x 2-1/4” Anchor Screws DO NOT fasten A237R clips to framing members with nails. Use only approved screws. Phone: 845.388.1200 Fax: 845.388.1388

Transcript of TMS Silent Clips - A237R · 2016. 9. 19. · TMS Silent Clips - A237R Installation Instructions...

Page 1: TMS Silent Clips - A237R · 2016. 9. 19. · TMS Silent Clips - A237R Installation Instructions Installation Notes: A237R clips shall not exceed 48” on center Spacing between hat

www.TMSoundproofing.com

TMS Silent Clips - A237R

Installation Instructions

A237R Specifications:

● Width: 1.375”● Height: 3.25”● Depth: 1.125”● Weight: 0.25 Lbs● Max spacing between clips: 48” OC● Max load: 36 Lbs.

Furring Channel Specifications:

● Minimum: 25 Gauge with hemmed edge● Depth: 7/8” or 1-1/2”● Width at top: 1-1/4”● Width at bottom: 2-1/2”* When splicing hat channel, overlap 6 inches

in between two A237R clips. Secure the channel with two 7/16” framing screws or 18 Gauge tie wire can be used.* Available at your local building supply stores

Fasteners:

A. Wood: # 8 x 2-1/2” Coarse ThreadsB. Steel: #8, #10 or #12 x 1- 5/8” Self Tapping

Type SC. Concrete: 3/16” x 2-1/4” Anchor Screws

DO NOT fasten A237R clips to framing members with nails. Use only approved screws.

Phone: 845.388.1200Fax: 845.388.1388

Page 2: TMS Silent Clips - A237R · 2016. 9. 19. · TMS Silent Clips - A237R Installation Instructions Installation Notes: A237R clips shall not exceed 48” on center Spacing between hat

www.TMSoundproofing.com

TMS Silent Clips - A237R

Installation Instructions

Installation Notes:

● A237R clips shall not exceed 48” on center

● Spacing between hat channels shall not exceed 24”

● Fasten the A237R clips to the substrate with a fastener approved for a minimum pull-out and shear of 120 Lbs.

● Locate the bottom row of A237R clips within 3” of the floor. (May be adjusted lower to accommodate installation of baseboard)

● Hat Channels are installed horizontal to the floor.

● Use a 4' level to ensure that A237R clips and furring channels are installed horizontal and level.

● Install the drywall vertically from the bottom up leaving a 1/4” thick gap around perimeter of wall to be filled with acoustical caulk. Caulk around the entire perimeter of the gypsum board.

Step 1:Review layout guidelines before starting installation of walls or ceilings (see Page 6). We suggest installing the ceiling first, before installing the walls.

Step 2:Space A237R clips so not to exceed 48” OC. Secure clips with a single fastener through the middle screw hole in the clip (Fig 2.1).

FOR FIRE RATED APPLICATIONS SEE PAGE 4 FOR INSTALLATION INSTRUCTIONS

Wood: Use #8 x 2-1/2” coarse thread screwsSteel: Use #8, #10 or #12 x 1- 5/8 Type s Self tapping screwsConcrete: Use 3.16” x 2 1/4” Tapcon or equal anchor

Step 3:Snap hat channel on A237R clips (Fig 2.2)

Figure 2.1: Screw clips info stud wall

Figure 2.2: Snap hat channel into clip

Phone: 845.388.1200Fax: 845.388.1388

Page 3: TMS Silent Clips - A237R · 2016. 9. 19. · TMS Silent Clips - A237R Installation Instructions Installation Notes: A237R clips shall not exceed 48” on center Spacing between hat

www.TMSoundproofing.com

TMS Silent Clips - A237R

Installation Instructions

Step 4:

The Floor Shims are critical to ensure best results. Place 1/4” shims on floor in front of sole plate (Fig 3.1). Install the first row of drywall vertically against the wall (Fig. 3.2). Attach drywall to channel following local building codes.

Note: Only remove the shims after all the gypsum board is completely screwed to all furring channels.

Step 5:

Use acoustical caulk around the entire perimeter of each wall (See Figure 3.3)

Load Specification for A237R Clip:

A237R Clips are designed to carry furring channel with one or more layers of gypsum wallboard attached. The load capacity of the clips depends on the gauge of the hat channel used.

25 Gauge furring channel carries less load that 22 Gauge channel but performs better acoustically. The maximum design load capacity for theA237R clips in shear ( Wall Application) or in tension (Ceiling Applications) as follows. Design load calculations are based on testing loading to failure where the furring channel deforms.

Maximum Load for Wall and Ceiling

2:1 safety factor 2.5:1 safety factor*

Resilmount Clips w/ 25 gauge hat channel

45 lbs 36 lbs

Resilmount Clips w/ 22 gauge hat channel

60 lbs 48 lbs

* Suggested safety factor 2.5:1 for more critical life safety applications

Note: 5/8” thick gypsum wallboard weighs w.3 lbs/sq ft.

1/2” thick gypsum wallboard weighs 1.85 lbs/sq ft.

Figure 3.1: Place shims on floor in front of base plate

Figure 3.2: Install drywall vertically to hat channels

Figure 3.3: Use Acoustical Caulk around the perimeter and edges

Figure 3.4: Tape and mud drywall

Phone: 845.388.1200Fax: 845.388.1388

Page 4: TMS Silent Clips - A237R · 2016. 9. 19. · TMS Silent Clips - A237R Installation Instructions Installation Notes: A237R clips shall not exceed 48” on center Spacing between hat

www.TMSoundproofing.com

TMS Silent Clips - A237R

Installation Instructions

Fire Rated Applications

Components:

● A237R Clips● ¼ x 1 Washer ● APPROVED SCREWS A. Wood: #8 x 2 1/2” Coarse ThreadB. Stell: #8 or #10 x 1-5/8” Self Tapping Type SC. Concrete: 3/16” x 2-1/2 Anchor Screws

On steel truss & C stud applications the screws are replaced with a ¼ x 1-1/2” bolt with a nylon nut.

DO NOT fasten A237R clips to framing members with nails. Use only approved screws.

Installation:

MUST READ A237R STANDARD INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE CLIPS.

VERY IMPORTANT: On Fire Rated Applications the A237R Washer must be installed as shown in FIG.1. If this washer is not installed the clip has no Fire Rating.

Phone: 845.388.1200Fax: 845.388.1388