Transcript of TMDE Program Life Cycle Conference Modernization and Calibration Measurement Requirement Summary...
TMDE Program Life Cycle Conference
Modernization andCalibration Measurement Requirement Summary
CMRS
Greg Hogan
NSWC Corona Det Seal Beach
TMDE Program Life Cycle Conference
• Technical Measurement RequirementDeveloped from Prime System requirements
• Contracting/Active ProcurementWorking with Industry to get best value
• Warranty CoverageIncluded in contract negotiation, ideally 3-5 years if available
• Post-Warranty SupportRCC or OEM, most logistically efficient
• Legacy SupportDesignated Overhaul Point establishment and/or ‘Fly-til-
Fail’ with technology back-up or alternative/shift• Obsolescence
If requirement still exists, then process recycles
Life Cycle Stages
TMDE Program Life Cycle Conference
Known Life Cycle BITRs
Contracting and Procurement
Warranty Coverage
Post-Warranty SupportLegacy Support
Technical Measurement Requirement Definition
Obsolescence
Technology may no longer be available or cost effective
May not be of sufficient duration, cost effective, or OEM may not be
willing to accept risk
Maintainability of technology may be proprietary/unique
System developmental lead time may be insufficient to support fielding of TMDE in time for deployment schedules
DRMO may not be option if capability still required but no longer supported by industry
Commercial & DoD infrastructure capabilities may not exist
(Bumps In The Road)
TMDE Program Life Cycle Conference
Activity Interaction
IndividualSystem
Assessment
GroupedSystem
Requirements Categorized Measurement Requirements
(SCATs)
(Measurement Requirements)
Defined Measurement
Disciplines(Functional Groups)
NAVSEA TMDE Engineering & Lifecycle
Logistics Team
PS/E ISEAs
PS/E Acquisition Programs
RMCs(Subject Matter
Experts)
RMCCalibration
Centers
TYCOMS & FLEET REPS
SUPPLY(Purchase
Description and Contract Award)
TMRs
INPUT
FEEDBACK
TMDE Program Life Cycle Conference
1. Signal Generator 2. Digital Multimeters3. Baseband Generator4. Synchro Resolver5. Spectrum Analyzer6. Calibrator7. Logic Analyzer8. Oscilloscope9. Voltmeter10. Frequency11. LAN/WAN 12. Telcomm Analyzer13. Power Supply 14. Bit Error Rate Tester15. Comm Analyzer 16. Recorder17. Insulation Breakdown18. Power Analyzer 19. Component Test 20. Impedance Matcher21. Field Strength22. Noise
23. Radar Test Set24. Modulation Analyzer25. Probe26. Power Meter27. Attenuator28. Fiber Optics29. Distortion30. Data Analyzer31. Electrical Safety32. Network Analyzer33. Resistor34. Scalar Analyzer35. Photo Tachometer36. Resistance37. Capacitor 38. Amplifier 39. Humidity40. Dummy Load41. Temperature42. Transformer43. Time/Freq-Domain
Reflectometry
44. Ph
45. Phase Sequence
46. Audio Analyzer
47. Sound Level
48. Termination
49. Data Acquisition
50. Modulator
51. Adapter
52. Coupler
53. Detector
54. Divider
55. Filter
56. Conductivity
57. Earth Ground
58. Echo Box
59. Isolator
60. Battery Analyzer
61. PCB Test
62. Impedance
64. Vibration
65. Oxygen
66. Switch
67. Potentiometer
68. Mixer
69. Power Limiter
70. Antenna
71. Inductor
72. Torque
73. Earth Ground
74. Signature Analyzer
75. Teletype
76. Monitor
Functional Groups
TMDE Program Life Cycle Conference
Obsolescence IssuesObsolescence Issues
• Model obsolete without immediate direct replacement.
• Model no longer on contract.
• OPN requirements forefront of identifying obsolete GPETE.
• Conflicting equipment availability reports.
• Vendors not being proactive in reporting model obsolescence.
TMDE Program Life Cycle ConferencePast Year Efforts
SCAT_CD MOD_DESCP_ABBP_TX
4017 METER RADIATION NBM-520+2 PRB
4019 METER RADIATION NBM-520+4PRBS
4025 ANALYZER LOGIC 102 CH 100MHZ
4115 POWER SUPPLY 50VDC 1.5AMPS
4122 OHMMETER HI-RESOLUTION 2K OHMS
4236 METER CLAMP-ON AC 1000A 700V
4245 MULTIMETER 3.5 DGT AC,DC 1000V
4249 MULTIMETER 4.5 DGT AC/DC 1000V
4306 OSCILLOSCOPE FOUR TRACE 400MHZ
4553 TESTER SEMICONDUCTOR IC
4584 ANALYZER VOICE FREQ 42.5+425HZ
5359 TORQUE CALIBRATOR 0-800FT-LB
4541 MEGOHMMETER 0-5000V 100GOHM
4465 LAN CABLE TESTER
4405 GENERATOR, FUNCTION
TMDE Program Life Cycle ConferenceIn Progress
SCAT_CD MODEL DESCPRIPTION
4070 SYNCHRO TESTER 60+400HZ
4195 VOLTMETER 0DB/1V 100U-1000V
4262 METER DEVIATION FM 4-1000MHZ
4290 TIME DOMAIN REFLECTOMETER
4298 TIME DOMAIN REFLECTOMETER
4341 ANALYZER SPECTRUM 99HZ-1800MHZ
4344 ANALYZER DISTORTION 200KHZ
4362 GENERATOR FM/AM 50KHZ- 550MHZ
4363 GENERATOR AM/FM 9KHZ-2GHZ
4473 ANALYZER ANTENNA 2-1600 MHZ
4475 ANALYZER NETWORK 10MHZ-110GHZ
4659 TRANSFORMER ISOLATION 4:1 5KHZ
4734 ANALYZER SPECTRUM .1- 100KHZ
4940 POWER METER PK 0.1-18.0GHZ
TMDE Program Life Cycle ConferenceUpcoming
• In process to evaluation next obsolescence SCAT codes for review. Possible candidates.1. SCAT 4349 Audio Analyzer2. SCAT 4466 Network Analyzer3. SCAT 4591 Bit Rate Error Tester4. SCAT 4567 Optiview II Network Analyzer5. SCAT 4573 Network Analyzer 6. SCAT 4310 OTDR SM7. SCAT 4318 OTDR MM8. Fleet Input ___
TMDE Program Life Cycle ConferenceCMRSCMRS
•The Calibration and Measurement Requirements Summary The Calibration and Measurement Requirements Summary is a form used to document the measurements O-Level is a form used to document the measurements O-Level maintainers could be required to make on a specific Prime maintainers could be required to make on a specific Prime System, and to calculate the test equipment that will be System, and to calculate the test equipment that will be required to support those measurements.required to support those measurements.
• Actual Prime System measurements are defined:Actual Prime System measurements are defined:
• Volts, Amps, MHz, RPM, etc.Volts, Amps, MHz, RPM, etc.
• Required accuraciesRequired accuracies
• Unique conditional requirements (rare)Unique conditional requirements (rare)
• Sufficiently capable test equipment is matched to Sufficiently capable test equipment is matched to each measurement using 4-to-1 Test Accuracy Ratioeach measurement using 4-to-1 Test Accuracy Ratio
• Sufficiently capable cal standard or procedure is Sufficiently capable cal standard or procedure is matched to the test equipment listed (also 4:1 TAR)matched to the test equipment listed (also 4:1 TAR)
Category I
Category II
Category III
TMDE Program Life Cycle Conference
CMRS ResponsibilitiesCMRS Responsibilities
ISEAs/PEOs maintain
Category I Data only
(Prime System)
NAVSEA TMDE Team will maintain Categories II and III (Test Equipment and
Cal Standards)
TMDE Program Life Cycle Conference
CMRS DocumentationCMRS Documentation
Once Prime System Once Prime System measurement requirements measurement requirements
(Category I) are documented, (Category I) are documented, NAVSEA completes remainder NAVSEA completes remainder
of CMRS. ISEA is then only of CMRS. ISEA is then only responsible for updating O-responsible for updating O-
level maintenance parameters level maintenance parameters when necessary.when necessary.
TMDE Program Life Cycle Conference
Requirement Requirement
ConsolidationConsolidation
Prime SystemMeasurement
Parameter
Meas 1 (Volts)Meas 2 (Acc)Meas 3 (Res)
Meas n
System 1
850 Vdc4 %< 3.4 V
System 2
795 Vdc5 %< 4 V
System n
815 Vdc10 %< 8.2 V
PS/E#2
PS/E#1
PS/E#n
ISEA-provided
Category Idata
NAVSEA uses consolidated CMRS data for all serviced PS/E to develop the best match of GPETE requirements to cost.
TMDE Program Life Cycle ConferenceThe Bottom Line:The Bottom Line:
Make use of GPETE whenever possible.Make use of GPETE whenever possible.
• Once an ISEA completes the Category I data portion of the CMRS, NAVSEA then calculates and completes Category II and III. The complete CMRS for each system is then validated by the ISEA. Once validated, the responsibility to maintain a sufficiently capable and reliable inventory of GPETE and calibration standards rests with NAVSEA 04RM.
• Assuming the O-Level maintenance requirements for a given system do not change, the only further ISEA action in support of CMRS is to keep POC data current.
• NAVSEA will advise ISEAs when compatibility or technology advance/obsolescence compels a change in Category II equipment, and will resolve any needed shifts with the ISEA.
TMDE Program Life Cycle Conference Over 120 CMRS completed
to date
AN-BYK-6(V)1 CMRS
AN_BYH-1 CMRS
AN_BST-2 Cmrs form
BSR-1 Cmrs Template
AN-BSQ-9(V)4 CMRS
AN_BSQ-9(V) CMRS
AN_BRA-24 CMRS
AN_BQQ-10(V)4 CMRS
BLQ-10 CMRS
AN_APX-118 Cmrs
AN_USQ-172(V) CMRS
BQH-9V1 Cmrs
AN_SYQ-27 CMRS
AN_SXY-1 CMRS
AN_SSX-1 CMRS
AN_SSQ-137(V) CMRS
AN_SMQ-11D & E CMRS
AN_SSH-9 CMRS
AN_SSH-6 CMRS
AN_SPQ-9 CMRS
AN_SSW-2 CMRS