TM-Series CWDM Single-fiber Networking · The single-fiber CWDM filter units can be mounted...

2
The single-fiber CWDM filter units can be mounted stand-alone in the TM-101/-102 chassis or in the larger TM-301 or TM-3000 chassis where it can be combined with other CWDM or DWDM Traffic Units. See separate Data Sheets for more information about these products Data Sheet TM-Series TM-3000/-301/-101/-102 Double Dual GbE Transponder Quad MultiRate Transponder 8-port SDH/SONET MuxPonder TM-101/-102 TM-301 TM-3000 4xSTM-16/STM-64 MuxPonder The Transmode single-fiber configuration provides a higher degree of networking flexibility since each single-fiber within the fiber-pair can be used independently. This configuration is particularly effective when building bus and ring networks since the optical filters can be placed on either of the single-fibers to provide best transmission performance and/or to enable hitless future upgrades. One of the single-fibers can as an alternative be used for 10G connections using DWDM channels. The figure above shows an example where one single-fibre is used for a 4ch bus network, and the second single- fiber is used for an 8ch point-to-point connection. A bi-directional connection on a single-fiber is created using two separate wavelengths, one for up-link and one for down- link. The following wavelength pairs are used to create a bi-directional connection; Upper wavelength band: 1470/1490, 1510/1530, 1550/1570, 1590/1610nm Lower wavelength band: 1270/1290, 1310/1330, 1350/1410, 1430/1450nm The lower wavelength band does not use wavelengths 1370 and 1390nm. This is done to avoid the "water-peak" of standard G.652 fibres and thus open for using all 16 channels also on longer links. The intrinsic higher fiber attenuation in the lower wavelength band will however still limit the bridgeable distance and must be taken into account when designing the network. Plug-in units CWDM Single-fiber Networking 5 5 6 6 7 7 8 8 1 2 3 4 Single-fiber MDUC4-EA/1270 MDUC4-EB/1270 1 2 3 4 MDUC4-TA/1470 MDUC4-TB/1470 1 2 3 4 Single-fibre MDUC4-TA/1470 MDUC4-TB/1470 1 2 3 4 The upper wavelength band operates where the fiber attenuation is lowest and is thus the option for bus/ring networks where the optical losses from intermediate add/drop filters need to be taken into account. Optical Add/Drop filters are thus provided in the upper wavelength band only. The figure shows the two MDU's that operate in the upper wavelength band. Note the direction of the wavelengths: Note that the product codes are identical, apart from the "TA"and "TB" index. These indexes indcates the direction of the wavelengths. A "TA"- unit shall always be connected to a "TB"- unit. Both MDU units are half-sized units and can be mounted in passive slots in the TM-3000, TM-301 or TM-101/-102 chassis. 1470 1490 1470 1490 1510 1530 1510 1530 1550 1570 1550 1570 1590 1610 1590 1610 MDUC4-TA/1470 MDUC4-TB/1470 MDUC4-TA/1470 Transmits 1470, 1510, 1550, 1590nm MDUC4-TB/1470 Transmits 1490, 1530, 1570, 1610nm. CWDM 9 1 2 3 4 5 6 7 8 Nc I/O Mux (Rx) DeMux (Tx) 1510 blue 1470 gray 1550 yellow 1590 red 1530 1490 1570 1610 MDU C 4Ch-TA Transmode Line CWDM 9 1 2 3 4 5 6 7 8 Nc I/O Mux(Rx) DeMux (Tx) 1530 green 1490 violet 1570 orange 1610 brown 1510 1470 1550 1590 MDU C 4Ch-TB Transmode Line AD2X1C/yyyy CB Networks - Tel: 33 (0)1 72 74 16 25 - E-Mail: [email protected]

Transcript of TM-Series CWDM Single-fiber Networking · The single-fiber CWDM filter units can be mounted...

Page 1: TM-Series CWDM Single-fiber Networking · The single-fiber CWDM filter units can be mounted stand-alone in the TM-101/-102 chassis or in the larger TM-301 or TM-3000 chassis where

The single-fiberCWDM filter unitscan be mountedstand-alone in

the TM-101/-102 chassis or in the larger TM-301

or TM-3000 chassis where it can be combined with other CWDM

or DWDM TrafficUnits.

See separate Data Sheets for

more information about these

products

Data SheetTM-Series

TM-3000/-301/-101/-102

Double Dual GbETransponder

Quad MultiRateTransponder

8-port SDH/SONETMuxPonder

TM-101/-102

TM-301

TM-3000

4xSTM-16/STM-64MuxPonder

The Transmode single-fiber configuration provides a higher degree of networking flexibility since each single-fiber within the fiber-pair can be used independently. This configuration is particularly effective when building bus and ring networks since the optical filters can be placed on either of the single-fibers to provide best transmission performance and/or to enable hitless future upgrades. One of the single-fibers can as an alternative be used for 10G connections using DWDM channels. The figure above shows an example where one single-fibre is used for a 4ch bus network, and the second single-fiber is used for an 8ch point-to-point connection.

A bi-directional connection on a single-fiber is created using two separate wavelengths, one for up-link and one for down-link. The following wavelength pairs are used to create a bi-directional connection;

Upper wavelength band: 1470/1490, 1510/1530, 1550/1570, 1590/1610nmLower wavelength band: 1270/1290, 1310/1330, 1350/1410, 1430/1450nm

The lower wavelength band does not use wavelengths 1370 and 1390nm. This is done to avoid the "water-peak" of standard G.652 fibres and thus open for using all 16 channels also on longer links. The intrinsic higher fiber attenuation in the lower wavelength band will however still limit the bridgeable distance and must be taken into account when designing thenetwork.

Plug-in units

CWDM Single-fiberNetworking

5 5

6 67 7

8 8

1

23

4

Single-fiber

MD

UC

4-EA/1270 M

DU

C4-

EB/1

270

1

23

4

MD

UC

4-TA/1470 M

DU

C4-

TB/1

470

1

23

4

Single-fibre

MD

UC

4-TA/1470

MD

UC

4-TB/1470

1

23

4

The upper wavelength band operates where the fiber attenuation is lowest and is thus the option for bus/ring networks where the optical losses from intermediate add/drop filters need to be taken into account. Optical Add/Drop filters are thus provided in the upper wavelength band only.

The figure shows the two MDU's that operate in the upper wavelength band. Note the direction of the wavelengths:

Note that the product codes are identical, apart from the "TA"and "TB" index. These indexes indcates the direction of the wavelengths. A "TA"- unit shall always be connected to a "TB"- unit.

Both MDU units are half-sized units and can be mounted in passive slots in the TM-3000, TM-301 or TM-101/-102 chassis.

14701490

14701490

15101530

15101530

15501570

15501570

15901610

15901610

MD

UC

4-TA/1470

MD

UC

4-TB

/147

0

MDUC4-TA/1470 Transmits 1470, 1510, 1550, 1590nmMDUC4-TB/1470 Transmits 1490, 1530, 1570, 1610nm.

CWDM

9

1

2

3

4

5

6

7

8

Nc

I/O

Mux

(Rx)

De

Mux

(Tx)

1510blue

1470gray

1550yellow

1590red

1530

1490

1570

1610

MDU C4Ch-TA

Transmode

Line

CWDM

9

1

2

3

4

5

6

7

8

Nc

I/O

Mux(

Rx)

De

Mux

(Tx)

1530green

1490violet

1570orange

1610brown

1510

1470

1550

1590

MDU C4Ch-TB

Transmode

Line

AD2X1C/yyyy

CB Networks - Tel: 33 (0)1 72 74 16 25 - E-Mail: [email protected]

Page 2: TM-Series CWDM Single-fiber Networking · The single-fiber CWDM filter units can be mounted stand-alone in the TM-101/-102 chassis or in the larger TM-301 or TM-3000 chassis where

[email protected]+46 (0)8 527 675 50

web:email:

telephone:

Transmode Systems AB

SE-126 14 StockholmSweden

BOX 42114

Mentis Platform

The TM-series Platform entails both CWDM and DWDM solutions

in single-fibre or fibre-pair

configurations. All in the same

card cage, one thesame fibre andunder the same

node and network management

system.

9xGbE/10GMuxponder

mROADM

6-port Ethernet Demarcation Unit

EmbeddedNode Manager (ENM)

TransmodeNetwork Manager (TNM)

Double 10GbE DWDM Transponder

10G Tunable Transponder

The specifications and information within this document are subject to change without further notice. All statements, information and recommendations are believed to be accurate but are presented without warranty of any kind.

1ch Add/Drop units are provided in both upper and lower wavelength band; One unit type has a single 1ch AD-filter and another has two 1ch AD-filters connected back-to-back as shown in the figure.

The 2x 1chAD-filters provide a more compact solution for bus networks where an add/drop in both east and west direction is needed.

All AD-filters are half-sized units.

AD2X1C/1590AD2X1C/1470 AD2X1C/1510 AD2X1C/1550

1470

1490

2x 1ch AD

1510

1530

1550

1570

1590

1610

1470

1490

1510

1530

1550

1570

1590

1610

CWDM

AD 2x1ChCWDM

2

Line

6

5A

B

4

3

A/D A

1

Tx

Rx

A/D B

1470

Rx

Tx

1490

Transmode

CWDM

Transmode

Line

4

3Ext

I/O

1

2

A/D

1470

1490

AD 1ChCWDM

1ch AD

To MDUC4-TA/1470 To MDUC4-TB/1470

To enable up to 8 bidirectional channels on a single-fibre, a MDU-pair for the lower wavelength band can be used. The index "E" indicates that they have an extension port that can be connected to the MDU's in the upper wavelength band and thus giving a 4+4 channel system on a single-fibre.

MDUC4-EA/1270 Transmits 1270, 1310, 1350, 1430nmMDUC4-EB/1270 Transmits 1290, 1330, 1410, 1450nm

The MDUC4-EA/1270 can be combined with a MDUC4-TA/1470 and the MDUC4-EB/1270 can be combined with a MDUC4-TB/1470 to form a 8ch connection. All MDU's are half-sized units.

CWDM

9

1

2

3

4

5

6

7

8

Ext

I/O

Mux

(Rx)

De

Mux

(Tx)

1310

1270

1350

1430

1330

1290

1410

1450

MDU C4Ch-EA

Transmode

Line

10

CWDM

9

1

2

3

4

5

6

7

8

Ext

I/O

Mux

(Rx)

De

Mux

(Tx)

1330

1290

1410

1450

1310

1270

1350

1430

MDU C4Ch-EB

Transmode

Line

10

MDUC4-EA/1270 MDUC4-EB/1270

12701290

13101330

13501410

14301450

MD

UC

4-EA/1270 M

DU

C4-

EB/1

270

12701290

13101330

13501410

14301450

Technical Data

MDUC4-EB/1470

5.6dBMDUC4-EA/1470

MDUC4-TB/1470

2.5dB 3.6dB

AD1C/yyyy AD2x1C/yyyy

3.3dB

2.7dBMDUC4-TA/1470

AD1C/yyyy 3.6dB

2.1dBAD2x1C/yyyy

4.2dB

2.7dB

3.3dB

Add/Drop losses when only using high wavelength units

Add/Drop losses when only using low wavelength units

MDUC4-TB/1470

7.7dB 6.2dB

AD1C/yyyy AD2x1C/yyyy

3.3dB

5.3dB

-

MDUC4-TA/1470

AD1C/yyyy 6.2dB

2.1dBAD2x1C/yyyy

4.2dB

5.3dB

3.3dB

Add/Drop losses when only using both high and low wavelength units

MDUC4-EA/1270

MDUC4-EB/1270

- 4.0dB 5.6dB

-

-

4.0dB

Input fiber type

MDUC4-TA/1470MDUC4-TB/1470

SM

MDUC4-EA/1270MDUC4-EB/1270

MU

SM

1471/14911511/15311551/15711591/1611 (G.694.2)

1271/12911311/13311351/14111431/1451 (G.694.2)

AD1C/yyyy AD2x1C/yyyy

Connector type

Wavelengths (nm)

MU

1471/14911511/15311551/15711591/1611 (G.694.2)

1471/14911511/15311551/15711591/1611 (G.694.2)

MU

SM

MU

SM

- 1.3dB 1.4dB-

Extension port loss 2.6dB- - -

Express loss

Misc Data

The two upper tables shows the end-to-end losses between different units. When designing links using the wavelength in the lower band, ensure to use the correct fibre attenuation values.

As can be seen in the tables, the wavelengths in the lower band have less attenuation through the MDU's compared to the wavelengths in the high band. This is to compensate for the higher fiber attenuation and thus give an overall lower loss.

The fiber attenuation in the low wavelangth band will be the limiting factor and will vary between different fibers. As a consequence, some of the 16 wavelengths cannot be used.

AD2X1C/1430AD2X1C/1270 AD2X1C/1310 AD2X1C/1350

1270

1290

1310

1330

1350

1410

1430

1450

1270

1290

1310

1330

1350

1410

1430

1450

DS-SF-CWDMRev C MAR 2008