TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
Transcript of TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
1/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
2/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
3/349
TM 10-5411-200-14
T.O. 35E4-177-1
W A R N I N G
HIGH VOLTAGE
exists in the electrical system of this equipment
DEATH ON CONTACT
may result if personnel fail to observe safety precautions
Before performing continuity checks or replacing electrical components,
make sure that electrical power is completely disconnected from the circuitinvolved.
In the event of fluorescent lamp breakage, care must be taken in the
removal of broken glass fragments and white phosphorous dust. Inhalation of
phosphorous dust could cause dangerous injury.
Do not use handling equipment with capacity of less than gross weight of
shelter system. Do not allow shelter to swing back and forth when it issuspended. Failure to observe this warning may result in damage to equipmentor severe injury or death to personnel.
Methylethylketone (MEK) is flammable and toxic and must be used only in
a well-ventilated area away from all sparks or open flame. Gloves should be
worn during use.
Lock stop plate on load balancer with quick release pin before disconnectingsupport cable from hinged floor.
In extreme cold, do not touch metal parts with bare hands. Severe skin
damage may result.
Safety glasses must be worn by personnel when installing ground anchors.
Expandable section (hinged floor and hinged sidewall together) weighs 700
pounds (318 kg). Do not stand directly in front of hinged section.
.Support cables attached to hinged floor must be locked out prior to
removal/installation of hinged sidewall.
Prior to removing load balancer from fixed roof, the hinged floor must be
near stowed position to remove tension from support cable. The support cablebracket on hinged floor must then be removed to permit disconnecting support
cable from hinged floor. Secure hinged floor to prevent accidental release.
Do not attempt to disassemble or repair load balancer. This equipment
contains powerful torsion springs and serious injury or death CO personnelcould result if disassembled.
a/(b blank)
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
4/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
5/349
TM 10-5411-200-14T.O. 35E4-177-1
CHANGENO. 9 HEADQUARTERS, DEPARTMENT OF THE ARMY
AND THE AIR FORCEWASHINGTON, DC, 31 AUGUST 2005
TECHNICAL MANUAL
OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERALSUPPORT MAINTENANCE
FORSHELTER, TACTICAL, EXPANDABLE, TWO-SIDED
NSN: 5411-01-136-9838
NSN: 5411-01-294-9866
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
TM 10-5411-200-14, 1 April 1986, is updated as follows:
1. File this sheet in front of the manual for reference.
2. This change implements Army Maintenance Transformation and changes theMaintenance Allocation Chart (MAC) to support Field and SustainmentMaintenance.
3. New or updated change information is indicated by a vertical bar in the outermargin of the page.
4. Remove old pages and insert new pages as indicated below:
Remove Pages Insert PagesA/(B Blank)
B-1 through B-11/(B-12 Blank) B-1 through B-12
Electronic 2028 Instructions Electronic 2028 Instructions/ Blank
DA Form 2028 2028 Sample Front/Back
2028 Front/2028 Back
2028 Front/2028 Back
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
6/349
ARMY TM 10-5411-200-14
C-9
By Order of the Secretary of the Army:
PETER J. SCHOOMAKER
General, United States Army
Chief of Staff
Official:
SANDRA R. RILEY
Administrative Assistant to the
Secretary of the Army0521009
MICHAEL E. RYAN
GENERAL, USAF
Chief of Staff
Official:GEORGE T. BABBETT
General, USAFCommander, Air Force Materiel Command
Distribution: To be distributed in accordance with initial distribution number (IDN) 252533 requirements forTM 10-5411-200-14.
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
7/349
CHANGE
NO. 8
ARMY TM 10-5411-200-14AIR FORCE T.O. 35E4-177-1
C8
HEADQUARTERS DEPARTMENTS OFTHE ARMY AND THE AIR FORCE
WASHINGTON, D.C., 20 JANUARY 1997
Operator, Organizational, Direct Support, and General Support
Maintenance Manual
SHELTER, TACTICAL, EXPANDABLE, TWO-SIDEDNSN 5411-01-136-9838 (60 AMP MODEL)NSN 5411-01-294-9866 (100 AMP MODEL)
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited
TM 10-5411-200-14/ T.O. 35E4-177-1,1 April 1986, is changed as follows:
1. The Cover is changed to add the 100 Amp Model.
2. Remove and insert pages as indicated below. New or changed text material is indicated by avertical barin the margin. An illustration change is indicated by a miniature pointing hand.
Remove pages
2-1 and 2-2
2-3 and 2-4
2-17 and 2-18
2- 8.1/ (2-18.2 blank)
4-23 through 4-26
4-39 through 4-46
4-179 and 4-160
4-181 and 4-182
4-185 and 4-186
C-5/ (C-6 blank)
E-31 (E-4 blank)
Cover
Insert pages
2-1 and 2-2
2-3 and 2-4
2-17 and 2-18
2-18.1 through 2-18.3 (2-18.4 blank)
4-23 through 4-26
4-39 through 4-46
4-179 and 4-180
4-180.1 and 4-180.2
4-181 and 4-182
4-182.1 (4-182.2 blank)
4-185 and 4-186
4-186.1/ (4-186.2 blank)
C-5/ (C-6 blank)
E-3/ (E-4 blank)
Cover
3. Retain this sheet in front of manual for reference purposes.
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
8/349
ARMY TM 10-5411-200-14AIR FORCE T.O.35E4-177-1
C8
By Order the Secretaries of the Army and Air Force:
General, United States ArmyChief of Staff
Administrative Assistant to theSecretary of the Army
03151
RONALD R. FOGELMAN
General, USAF
Chief of Staff
HENRY VICCELLIO, JR.General, USAF
Commander, Air Force Materiel Command
DISTRIBUTION:To be distributed in accordance with DA Form 12-25-E, block no. 2533, requirements for
TM 10-5411-200-14.
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
9/349
C H A N GE
NO. 7
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
C 7
H E A D QU A R T E R SDEPARTMENTS OF THE ARMY AND THE AI R FORCE
WA SHI NGT ON, D. C. , 1 5 De c e mb e r 1 9 9 4
Op e r a t o r , Or g a n i z a t i o n a l , Di r e c t S u p p o r t , a n d Ge n e r a l Su p p o r t
Ma i n t e n a n c e Ma n u a lF o r
S HE L T E R, T A CT I CA L E XP ANDA BL E , T WO- S I DE D
( NS N 5 4 1 1 - 0 1 - 1 3 6 - 9 8 3 8 ) ( 6 0 A mp Mo d e l )
( NS N 5 4 1 1 - 0 1 - 2 9 4 9 8 6 6 ) ( 1 0 0 Amp Mo d e l )
DI S T RI BUT I ON ST AT EME NT A: A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d .
T M 1 O- 5 4 1 1 - 2 OO- 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d a s f o l l o ws :
1 . R emo v e a n d i n s e r t p a ge s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i s i n d i c a t e d b y a v e r t i c ai n t h e ma r g i n . A n i l l u s t r a t i o n c h a ng e i s i n d i c a t e d b y a mi n i a t u r e p o i n t i n g h an d .
R e m o v e p a g e s I n s e r t p a g e s
1 - 1 a n d 1 - 2 1 - 1 a nd 1 - 2
D- 1 / ( D- 2 b l a nk ) D- 1 a n d D- 2
2 . R e t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
10/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E 4 - 1 7 7 - 1
C 7
By Or d e r o f t h e S e c r e t a r l e s o f t h e Ar my a n d Ai r F o r c e :
O f f i c i a l :
MI L T O N H. HA MI L T O NA d m i n i s t t a t i v e A s s i s t a n t t o t h e
S e c r e t a r y o f t h e A r my 0 7 6 6
GOR DON R. S UL L I V A NGe n e r a l , Un i t e d St a t e s A r my
C h i e f o f S t a f f
ME RRI L L A . Mc P E A KGe n e r a l , USAFCh i e f o f S f a f f
R ON A L D W. Y A T E S
Ge n e r a l , US A F Co mma n d e r A i r F o r c e Ma t e r i e l Co mma n d
DI S TRI B UT I ON:
T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA Fo r m 1 2 - 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o rT M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
11/349
CHANGE
NO. 6
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
C 6
HEADQUARTERSDEPARTMENTS OF T HE ARMY AND A I R FORCE
WASHI NGT ON, D. C. , 2 8 F e b r u a r y 1 9 9
Op e r a t o r , Or g a n i z a t i o n a l , Di r e c t Su p p o r t , a n d Ge n e r a l
Ma i n t e n a n c e Ma n u a l
S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D( NSN 5 4 1 1 - 0 1 - 1 . 3 6 - 9 8 3 8 ) ( 6 0 Amp Mo d e l )( NSN 5 4 1 1 - 0 1 - 2 9 4 - 9 8 6 6 ) ( 1 0 0 Amp Mo d e l )
DI S T RI B UT I ON S T AT E ME NT A : A p p r o v ed f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d .
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d a s f o l l o ws :
1 . Re mo v e an d i n s e r t p a ge s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i si n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n . An i l l u s t r a t i o n c h a n g e i s i n d i c a t eb y a mi n i a t u r e p o i n t i n g h a n d .
R e m o v e p a g e s I n s e r t p a g e s
i a n d i i i a n d i i2 - 3 1 a n d 2 - 3 2 2 - 3 1 a n d 2 - 3 2C- 3 a n d C- 4 C- 3 a n d C- 4
2 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
12/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O . 3 5 E 4 - 1 7 7 - 1
C- 6
B y Or d e r o f t h e Se c r e t a r i e s o f t h e Ar my a n d A i r F o r c e :
Of f i c i a l :
GOR DON R. S UL L I V A NGe n e r a l , Un i t e d St a t e s A r my
Ch i e f o f S t a f f
MI L T O N H . H AMI L T O NA d m i n i s t r a t i v e A s s i s t a n t t o t h e
S e c r e t a r y o f t h e A r m y 0 6 2 5 6
ME RR I L L A . Mc P E AKGe n e r a l , US AF Ch i e f o f S t a f f
O f f i c i a l :
R ON A L D W. Y A T E SGe n e r a l , US AF Co mma n d e r A i r F o r c e Ma t e r i e l Co mma n d
DI S T RI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F o r m 1 2 - 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o r
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
13/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
14/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E 4 - 1 7 7 - 1
B y Or d e r o f t h e Se c r e t a r i e s o f t h e Ar my a n d Ai r F o r c e :
O f f i c i a l :
GOR DON R. S UL L I V A N
Ge n e r a l , Un i t e d St a t e s A r my C h i e f o f S t a f f
MI L T O N H. HA MI L T O NA d mi n i s t r a t i v e A s s i s t a n t t o t h e
S e c r e t a r y o f t h e Ar my 0 4 9 9 0
ME RR I L L A . Mc P E AKGe n e r a l , US AF Ch i e f o f S t a f f
o f f i c i a l :
R ON A L D W. Y A T E SGe n e r a l , US AF C o mma n d e r A i r F o r c e Ma t e r i e l C o mma n d
DI S TRI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F or m 1 2 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o r
T M 1 0 5 4 1 1 2 0 0 - 1 4 .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
15/349
A RMY T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4A I R F ORCE T. O. 3 5 E 4 - 1 7 7 - 1
C 4
CHANGE HEADQUARTERS,
DEPARTMENTS OF THE ARMY AND AI R FORCENO. 4 WA SHI NGT ON, D. C. 3 0 A p r i l 1 9 9 3
Op e r a t o r , Or g a n i z a t i o n a l , D i r e c t S u p p o r t , a n d Ge n e r a l S u p p o r tMa i n t e n a n c e Ma n u a l
S HE L T E R, T A CT I C AL , E X PA ND AB L E , T WO- S I D ED
D I S T R I B UT I ON S T A T E ME NT
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O.
NS N 5 4 1 1 - 0 1 - 1 3 6 - 9 8 3 8 ( 6 0 A MP MODE L )N SN 5 4 1 1 - 0 1 - 2 9 4 - 9 8 6 6 ( 1 OO A MP MODE L )
A : A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d .
3 5 E 4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 i s c h a n g e d a s f o l l o ws :
1 . Re mo v e an d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i si n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n . A n i l l u s t r a t i o n c h a n g e i s i n d i c a t e db y a mi n i a t u r e p o i n t i n g h a n d .
R e m o v e p a g e s I n s e r t p a g es
4 - 1 7 1 a n d 4 - 1 7 2 4 - 1 7 1 a n d 4 - 1 7 2D- 1 / ( D- 2 b l a n k ) D- 1 / ( D- 2 b l a nk )E- 1 t h r o u g h E - 3 / ( E- 4 b l a n k ) E- 1 t h r o u g h E- 3 / ( E- 4 b l a n k )
2 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
16/349
A RMY T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4A I R F ORCE T . O. 3 5 E 4 - 1 7 7 - 1
B y Or d e r o f t h e Se c r e t a r i e s o f t h e Ar my a n d A i r F o r c e :
Of f i c i a l :
GOR DON R. S UL L I V A N
Ge n e r a l , Un i t e d St a t e s A r my C h i e f o f S t a f f
MI L T O N H . H AMI L T O N
A d m i n i s t r a t i v e A s s i s t a n t t o t h e S e c r e t a r y o f t h e A r m y
0 4 0 7 8
ME RRI L L A . Mc P EA K
Ge n e r a l , US A F Ch i e f o f S t a f f
Of f i c i a l :
R ON A L D W. Y A T E S
Ge n e r a l , US A F C o mma n d e r , A i r F o r c e Ma t e r i e l C o mma n d
DI S TRI B UT I ON:
T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F o r m 1 2 - 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o rT M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 . .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
17/349
C H A N G E
NO. 3
A RMY T M 1 0 - 5 4 1 1 - 2 0 0 - 1A I R F ORCE T . O. 3 5 E 4 - 1 7 7 -
C 3
H E A D Q u A R T E R S ,DEPARTMENTS OF T HE ARMY AND A I R FORCE
WA SHI NGT ON, D. C. , 2 3 Ma y 1 9 9 1
Op e r a t o r , Or g a n i z a t i o n a l , Di r e c t S u p p o r t a n d Ge n e r a l S u p p o r tMa i n t e n a n c e Ma n u a l
S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D
NS N 5 4 1 1 - 0 1 - 1 3 6 9 8 3 8 ( 6 0 A MP MODE L )
NS N 5 4 1 1 4 1 - 2 9 4 - 9 8 6 6 ( 1 0 0 A MP MODE L )
A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d
T M 1 0 - 5 4 1 1 2 0 0 - 1 4 / T . O . 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 i s c h a n g e d a s f o l l o ws :
1 . R emo v e a n d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i s i n d i c a t e d b y a v e r t i c a l
t h e ma r g i n . A n i l l u s t r a t i o n c h a n g e i s i n d i c a t e d b y a mi n i a t u r e p o i n t i n g h a n d .
R e m o v e p a g e s I n s e r t p a g e s
1 - 1 a n d 1 2 1 - 1 a n d 1 2
1 - 5 a n d 1 - 6 1 - 5 a n d 1 - 6
C 3 a n d C - 4 C 3 a n d C - 4
2 . R e t a i n t h i s s h e e t i n f r o n t o f m a n u a l f o r r e f e r e n c e p u r p o s e s .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
18/349
By Or d e r o f t h e Se c r e t a r i e s o f t h e Amy a n d A i r F o r c e :
C A RL E . V U ON O
Ge n e r a l , Un i t e d S t a t e s Ar my
Ch i e f o f S t a f f
O f f i c i a l :P AT RI CI A P. HI CK ERS ON
Co l o n e l , Un i t e d St a t e s Ar my T h e A d j u t a n t Ge n e r a l
ME RRI L L A . Mc P EA K
Ge n e r a l U S A F C h i e f o f S t a f f
O f f i c i a l :
C HA RL E S C . Mc D ON A L D
Ge n e r a l , US A F
Co mma n d e r , A i r F o r c e L o g i s t i c s C o mma n d
DI S TRI B UT I ON:
T o b e d i s t r i b u t e d i n a c c o r d a nc e wi t h DA F or m 1 2 - 2 5 E , ( q t y r q r b l o c k no . 2 5 3 3 ) .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
19/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
CHANGE
No . 2
H E A D QU A R TE R S , D E P A R TME N TS OFTH E A R MY A N D TH E A I R FO RC E
WA SHI NGT ON, D. C. , 1 4 F e b r u a r y 1 9 9 0
Op er a t o r , Or g a n i z a t i o na l , Di r e c t Su p p o r t ,An d Ge n e r a l Su p p o r t Ma i n t e n a n c e
S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D( NSN 5 4 1 1 - 0 1 - 1 3 6 - 9 8 3 8 ) ( 6 0 A mp Mo d e l )
( NSN 5 4 1 1 - 0 1 - 2 9 4 - 9 8 6 6 ) ( 1 0 0 Amp Mo d e l )
Ap pr o v e d f o r p u b l i c r e l e a s e ; Di s t r i b u t i o n i s u n l i mi t e d .
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d as f o l l o ws :
1 . T i t l e i s c h a n g e d a s s h o wn a b o v e .
2 . Re mo v e a n d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a li s i n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n . An i l l u s t r a t i o n c h a n g e i s i n d i c a t e db y a mi n i a t u r e p o i n t i n g h a n d .
R e m o v e p a g e s I n s e r t p a g e s
i a n d i i1 - 1 t h r o u g h 1 - 62 - 1 a n d 2 - 22 - 9 t h r o u g h 2 - 1 42 - 1 7 a n d 2 - 1 8- - -
2 - 2 1 t h r o u g h 2 - 2 4- - - -
2 - 2 9 a n d 2 - 3 03 - 7 a n d 3 - 8
4 - . 5 t h r o u g h 4 - 1 2- - -
4 - 1 3 a n d 4 - 1 44 - 2 7 t h r o u g h 4 - 3 64 - 4 7 t h r o u g h 4 - 5 4- - -
4 - 5 5 a n d 4 - 5 64 - 1 7 9 t h r o u g h 4 - 1 8 6- - -
5 - 5 t h r o u gh 5 - 8A - 1 / A - 2D- 1 / D- 2E- 1 a n d E - 2
- - -I n d e x 1 t h r o u g h I n d e x 4
i a n d i i1 - 1 t h r o u g h 1 - 62 - 1 a n d 2 - 22 - 9 t h r o u g h 2 - 1 42 - 1 7 a n d 2 - 1 82 - 1 8 . 1 / 2 - 1 8 . 22 - 2 1 t h r o u g h 2 - 2 42 - 2 4 . 1 / 2 - 2 4 . 22 - 2 9 a n d 2 - 3 03 - 7 a n d 3 - 84 - 5 t h r o u g h 4 - 1 24 - 1 2 . 1 a n d 4 - 1 2 . 24 - 1 3 a n d 4 - 1 44 - 2 7 t h r o u g h 4 - 3 64 - 4 7 t h r o u g h 4 - 5 44 - 5 4 . 1 a n d 4 - 5 4 . 24 - 5 5 an d 4 - 5 64 - 1 7 9 t h r o u g h 4 - 1 8 64 - 1 8 7 t h r o u g h 4 - 1 9 05 - 5 t h r o u g h 5 - 8A - 1 / A - 2D- 1 / D- 2E- 1 a n d E - 2
E - 3 / E - 4I n d e x 1 t h r o u g h I n d e x 4
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
20/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
C 2
3 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e pu r p o s e s .
By Or d e r o f t h e Se c r e t a r i e s o f t h e A r my a n d t h e A i r F o r c e :
C A RL E . V U ON 06 e n e r a l , Un i t e d S t a t e s Amy
Ch i e f o f S t a f f
Of f i c i a l :WI L L I AM J . ME EHA N, I I
B r i g a d i e r 6 e n e r a l , Un i t e d S t a t e s Ar myT h e Ad j u t a n t 6 e n e r a l
L A RRY D. WE L CH, 6 e n e r a l US AFCh i e f o f S t a f f
Of f i c i a l :A L F R E D G. H AN SE N
Ge n e r a l , USAF , Co mma n d e r , A i r F o r c eL o g i s t i c s C omma n d
DI S TRI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA 1 2 - 2 5 A , Op e r a t o r , Un i t , Di r e c t Su p p o r t
a n d Ge n e r a l Su p p o r t Ma i n t e n a n c e r e q u i r e me n t s f o r S h e l t e r , Ex p a n d a b l e , 2 - S i d e( 5 - 4 - 3 1 1 8 - 2 ) .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
21/349
CHANGE
No . 1
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 W4 - 1 7 7 - 1
C 1
HEADQUARTERSDEPARTMENTS OF T HE ARMY AND AI R FORCE
WAS HI NGT ON, D. C. , 8 J u n e 1 9 8 9
Op er a t o r , Or g a n i z a t i o n a l , Di r e c t Su p p o r t
a n d Ge n e r a l Su p p o r t Ma i n t e n a n c e
S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D( NSN 5 41 1 - 0 1 - 1 3 6 - 9 8 3 8 )
Ap p r o v e d f o r p u b l i c r e l e a s e . Di s t r i b u t i o n i s u n l i mi t e d .
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d a s f o l l o ws :
1 . Re mo v e a n d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a li s i n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n , An i l l u s t r a t i o n c h a n g e i s i n d i c a t e db y a mi n i a t u r e p o i n t i n g h a n d .
R e m o v e p a g e s I n s e r t p a g e s
2 - 2 9 a n d 2 - 3 0 2 - 2 9 a n d 2 - 3 0D- 1 / D- 2 D- 1 / D- 2
2 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s .
By Or d e r o f t h e Se c r e t a r i e s o f t h e A r my a n d t h e A i r F o r c e :
C A RL E . V U ON O
Ge n e r a l Un i t e d St a t e s A r my
O f f i c i a l :
WI L L I AM J . MEE HA N, I IB r i g a d i e r Ge n e r a l , Un i t e d St a t e s A r my
T h e A d j u t a n t Ge n e r a l
O f f i c i a l :
A LF R E D G. H A NS E N
Ge n e r a l , US A F , Co mma n d e r , A i r F o r c e L o g i s t i c s Co mma n d
Ch i e f o f S t a f f
L A R R Y D . WE L C H , Ge n e n a l US A F Ch i e f o f S t a f f
DI S TRI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F o r m 1 2 - 2 5 A , Op e r a t o r , Un i t , Di r e c t
Su p p o r t a n d Ge n e r a l S u p p o r t Ma i n t e n a n c e r e q u i r e me n t s f o r S h e l t e r , Ex p a n d a b l e ,Ri g i d Co n s t r u c t i o n , W/ A i r L o c k Mo d e l SEU- 2 ( T M 1 0 - 5 4 1 0 - 2 2 1 Se r i e s ) a n d f o rSh e l t e r , E x p a n d a b l e , S h o p , A i r c r a f t Ma i n t e n a n c e , Po r t a b l e ( T M 1 0 - 5 4 1 0 - 2 2 4 Se r i e s ) .
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
22/349
TM 10-5411-200-14T.O. 35E4-177-1
INSERT LATEST CHANGED PAGES. DESTROY SUPERSEDED PAGES.
A/(B Blank) Change 9USA
LIST OF EFFECTIVE PAGES
NOTE: The portion of text affected by the update is indicated by a vertical line in the outer margins of the
page. Updates to illustrations are indicated by shaded or screened areas, or by miniaturepointing hands. Zero in the Change No. column indicates an original page or work package.
Dates of issue for original and changed pages / work packages are:
Original .. 0 .. 1 April 1986 Change .. 5 .. 30 July 1993
Change .. 1 .. 8 June 1989 Change .. 6 .. 28 February 1994
Change .. 2 .. 14 February 1990 Change .. 7 .. 15 December 1994
Change .. 3 .. 23 May 1991 Change .. 8 .. 20 January 1997
Change .. 4 .. 30 April 1993 Change .. 9 .. 31 August 2005
TOTAL NUMBER OF PAGES FOR THIS PUBLICATION IS 350, CONSISTING OF THE FOLLOWING:
PageNo.
ChangeNo.
PageNo.
ChangeNo.
PageNo.
ChangeNo.
PageNo.
ChangNo.
Cover 0 2-15 through 2-17 0 4-26 8 5-5 2
a/(b Blank) 02-18 through2-18.3/(2-18.4 Blank)
8 4-27 0 5-6 0
i 6 2-19 through 2-21 0 4-28 through 4-36 2 5-7 2
ii 2 2-22 2 4-37 through 4-39 0 5-8 through 5-14 0
1-0 0 2-23 0 4-40 through 4-45 8 6-1 through 6-4 0
1-1 22-24 through2-24.1/(2-24.2 Blank)
2 4-46 0 A-1/(A-2 blank) 2
1-2 7 2-25 through 2-28 0 4-47 through 4-55 2 B-1 through B-12 9
1-3 2 2-29 through 2-30 2 4-56 through 4-92 0 C-1 through C-3 0
1-4 0 2-31 6 4-93 through 4-95 5 C-4 6
1-5 3 2-32 through 2-36 0 4-96 through 4-99 0 C-5/(C-6 blank) 8
1-6 2 3-1 through 3-7 0 4-100 through 4-108 5 D-1 through D-2 7
2-1 8 3-8 2 4-109 through 4-179 0 E-1 0
2-2 23-9 through3-15/(3-16 Blank)
04-180 through4-182.1/(4-182.2 Blank)
8 E-2 4
2-3 8 4-1 through 4-4 0 4-183 2 E-3/(E-4 blank) 8
2-4 through 2-8 0 4-5 through 4-13 2 4-184 through 4-185 0 Index-1 2
2-9 through 2-12 2 4-14 through 4-22 04-186 through4-186.1/(4-186.2 Blank)
8 Index-2 0
2-13 0 4-23 through 4-24 8 4-187 through 4-190 2Index-3 throughIndex-4
2
2-14 2 4-25 0 5-1 through 5-4 0 Back Cover 0
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
23/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
24/349
TM 10-5411-200-1T.O. 35E4-177-
TECHNICAL MANUAL HEADQUARTERS, DEPARTMENTS
THE ARMY AND THE AIR FORNO. 10-5411-200-14 WASHINGTON, D.C., 1 April 19
OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT,
AND GENERAL SUPPORT MAINTENANCE
SHELTER, TACTICAL, EXPANDABLE, TWO-SIDED
(NSN 5411-01-136-9838)(60 Amp Model)
(NSN 5411-01-294-9866)(100 Amp Model)
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimite
L
REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS
You can help improve this manual. If you find any mistakes or if you know of
a way to improve the procedures, please let us know. Reports shall be sub-mitted as follows: A reply will be furnished to you.
(A) Army - DA Form 2028 (Recommended Changes to Publications and BlankForms), or DA Form 2028-2 located in the back of this manual direct to:
Commander, U.S. Army Aviation and Troop Command, ATTN: AMSAT-I-MP, 430
Goodfellow Boulevard, St. Louis, MO 63120-1798.
(F) Air Force - AFTO Form 22 directly to: Commander, Sacramento AirLogistics Center, ATTN: MMST, McClellan Air Force Base, CA 95652 inaccordance with TO-00-5-1,
CHAPTER 1
Section I.
Section II.
1-1
1-1
1-3
CHAPTER 2
Section I.
Section II.
Section III.
Section IV.
Section V.
CHAPTER 3Section I.
Section II.
TABLE OF CONTENTS
Page
INTRODUCTIONGeneral Information
Equipment Description and Data
OPERATING INSTRUCTIONS
Description and Use of Operators Controls and
Indicators
Operators Preventive Maintenance Checks and
Services (PMCS)Service Upon Receipt of Shelter
Operation Under Usual Conditions
Operation Under Unusual Conditions
OPERATOR MAINTENANCE INSTRUCTIONSTroubleshooting Procedures
Operator Maintenance Procedures
2-1
2-1
2-42-11
2-32
2-33
3-1
3-1
3-4
Change 6 i
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
25/349
TM 10-5411-200-14T.O. 35E4-177-1
TABLE OF CONTENTS (cont)
CHAPTER 4 ORGANIZATIONAL MAINTENANCE INSTRUCTIONS
Section I Repair Parts, ,Special Tools, TMDE, and Support
Equipment
Section II. Troubleshooting Procedures
Section III. Organizational Maintenance Procedures
Section IV. Preparation for Storage and Shipment
CHAPTER 5 DIRECT SUPPORT MAINTENANCE INSTRUCTIONS
CHAPTER 6 GENERAL SUPPORT MAINTENANCE INSTRUCTIONS
APPENDIX A REFERENCES
APPENDIX B MAINTENANCE ALLOCATION CHART
APPENDIX C COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS
LIST
APPENDIX D ADDITIONAL AUTHORIZED LIST
APPENDIX E EXPENDABLE SUPPLIES AND MATERIALS LIST
ALPHABETICAL INDEX
Page
4-1
4-1
4-2
4-5
4-190
5-1
6-1
A-1
B-1
C-1
D-1
E-1
INDEX-1
ii CHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
26/349
TM 10-5411-200-14
T.O. 35E4-177-1
EXPANDED SHELTER
Full External View of Two-Sided Expandable Tactical Shelter
1-0
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
27/349
TM 10-5411-200-14
T.O. 35E4-177-1
CHAPTER 1
INTRODUCTION
Section 1. GENERAL INFORMATION
1-1. SCOPE. This manual is for use by personnel responsible for operation and maintenance of the
two-sided expandable tactical shelter assembly, which will be referred to as the shelter. It provides the
user with necessary instructions to use the shelter and to perform required maintenance in accordance
with the Maintenance Allocation Chart in Appendix B.
NOTE
Some portions of this publication are not applicable to all services. These
portions are prefixed to indicate the services to which they pertain (A)
for Army, (F) for Air Force, and (N) for Navy. Portions not prefixed
are applicable to all services.
1-2. MAINTENANCE FORMS, RECORDS, AND REPORTS. Maintenance forms. records, and reports
used by:
a. (A) Are prescribed by DA PAM 736-750, the Army Maintenance Management System
(TAMMS).
b. (F) Are prescribed in AFM-66-1 and the applicable 00-20 Series Technical Orders.
c. (N) Refer to their service peculiar directives to dtermine applicable maintenance forms and
records to be used.
d. (A) Users shall refer to the Maintenance Allocation Chart (MAC) for task and levels ofmaintenance to be performed. Where the density of equipment is not sufficient to authorize unit
personnel with skills necessary to perform unit-level maintenance functions, AR 750-1, paragraph 2-8c
states, Unserviceable reparable, (properly preserved, protected, and tagged) that are beyond the
authorized capability or capacity to repair, will be evacuated through the appropriate SUPPLY support
activities for repair or exchange. For units authorized personnel with skills to perform greater than
unit-level maintenance functions, AR 750-1, paragaph 2-9b states, "DS and GS units may grant authority
to supported units to perform the next higher level repair, if the supported unit has the capability and
capacity to perform the repair.
(F) Users shall accomplish maintenance at the user level consistent with their capability in
accordance with policies established in AFM 66-1.
f. (N) Users shall determine their maintenance levels in accordance with their service directives.
1-3. (A) DESTRUCTION OF MATERIEL TO PREVENT ENEMY USE. For destruction procedures. for materiel refer to TM 750-244-3.
14. ADMINISTRATIVE STORAGE. For procedures and inspections required during administrative
storage, refer to Chapter 4, paragraph 4-44.
Change 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
28/349
TM 10-5411-200-14
T.O. 35E4-177-1
1-5. (A) REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATIONS (EIRS). If your shelterneeds improvement, let us know. Send us an EIR. You, the user, are the only one who can tell us what you
dont like about your equipment. Let us know why you dont like the design. Tell us why a procedure is hard
to perform. Put it on an SF 368 (Quality Deficiency Report). Mail it to: Commander, U. S. Army Aviation
and Troop command ATTN: AMSAT-I-MDO, 4300 Goodfellow Boulevard, St. Louis, Missouri, 63120-1798.
Well send you a reply.
1-6. LIST OF ABBREVIATIONS.
AC
cm
ECU
EIR
ft
Hz
in.
IS0
kg
lb pound
lg
MAC
MEK
m m
MTOE
No.
PMCS
ref
sq
TMDE
W C
Air conditioner
centimeter
Environmental Control Unit
Equipment Improvement Report
foot (feet)
Hertz
inch
International standards Organization
Kilogram
long
Maintenance Allocation chart
Methylethylketone (Solvent)
millimeter
Modified Table of Organization and Equipment
number
Preventive Maintenance Checks and Services
reference
square
Test, Measurement and Diagnostic Equipment
Volts, alternating current
1-2 Change 7
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
29/349
TM 10-5411-200-
T.O. 35E4-177-
Section II. EQUIPMENT DESCRIPTION AND DATA
1-7. PURPOSE OF TWO-SIDED EXPANDABLE TACTICAL SHELTER ASSEMBLY. A self-contained transportable multi-application utility shelter. A member of family
of standard rigid wall ISO shelters to be used by branches of the Department Defense.
Capabilities and Features:
q Equipped with standard ISO fittings for easy transportability.
q Provided with mobilizer fittings for mobilizer transportation.
q Built-in fork lift provisions.
q All weather operation.
q Environmentally controlled interior.
q Rigid wall construction.
q Simple and fast deployment.
q Designed to operate under blackout conditions with door activated blackoswitch.
q External electrical power connection.
q Easy to maintain.
Differences Between Models:
q The early model Shelter, Tactical, Expandable, Two-Sided (NSN 5411-01-13
9838), provides overload protection through a 60 amp or 100 amp Model NQ
circuit breaker panel, manufactured by Square D Company. When replacemeof the circuit breaker panel is necessary, the replacement will be Model
NQOD circuit breaker panel, which is also manufactured by Square D Compaand has the capability to accommodate either 60 amp or 100 amp service.
Model NQOD is two inches shorter in length than the earlier Model NQOB,
and modifications to the shelters are required when replacement is
necessary (see paragraph 4-7.1).
NOTE
All electrical components (circuit breakers, switches, andwiring) used in the earlier model circuit breaker panel arecompatible with the new Model NQOD.
q The late model Shelters, Tactical, Expandable, Two-Sided (NSN 5411-01-29
9866) are initially equipped with the new Model NQOD circuit breaker pan
when placed into service.
cHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
30/349
TM 10-5411-200-14T.O. 35E4-177-1
1-8. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS.
1-4
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
31/349
TM 10-5411-200-14T.O. 35E4-177-1
1-8. (cont)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
W A R N I N G
LEFT AND RIGHT CARGO DOORS, Provides access to shelter for delivery of bulky materiel and equipment
Door vents are spring loaded to swing upward. To prevent
injury, hold door vent shut while unlatching all the retaining
clips.
DOOR VENTS. Manually operated vents provide ventilation and pressure equalization for the shelter.
HINGED ENDWALLS. Hinged to center structure and swing out to form walls in the expandable section of
shelter.
HINGED SIDEWALL. Hinged to hinged floor panel. Forms a wall in the expandable section when shelter is
expanded.
LEVELING JACKS. Secured to hinged floor and hinged sidewall. Provides leveling means for the expandable
section.
HINGED FLOOR PANEL. Hinged to fixed floor panel. Provides additional floor space when shelter is expanded
EXPANDABLE SIDE LOAD BALANCER. Consists of cable reels, cable guides, and support cable to assist i
expanding and closing of hinged floor panel and hinged sidewall.
ECU PANELS. Provides for connections of ECU equipment used with shelter
Shelter grounding is not optional on shelters used for
Deployable Medical Systems (DEPMEDS).
POWER ENTRY PANEL. A service entrance connector on this panel receives external primary input power for
shelter and routes it to a circuit breaker panel inside the shelter. Includes provisions for optional shelter groundin
and telephone connections.
FIXED PERSONNEL DOOR. Provides access to shelter. The only door used during blackout conditions.
CONTAINER LIFT JACKS. Provides leveling means for fixed section of shelter by means of 150 fittings
EQUIPMENT CONTAINER CHEST. Contains leveling jack extensions, storm configuration (shelter tie-down
kit, area light incandescent bulb, removable latches, support braces, and screwdriver.
AREA LIGHT. Attaches to either personnel or cargo endwall panels to provide illumination at either end of
shelter. Plugs into receptacle on power entry panel.
CIRCUIT BREAKER PANEL. Provides overload protection for shelter circuits. Main circuit breaker switche
off all electrical power to shelter.
HINGED ROOF PANEL. Hinged to center structure roof. Swings up to provide roof for expandable section o
the shelter.
W a r n i n g
Change 3 1-5
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
32/349
TM 10-5411-200-14
T.O. 35E4-177-1
1-8. (cont)
16. FIXED PANELS. Consists of personnel and cargo end, fixed floor, and fixed.
roof panels. Used for equipment storage during transportation. All hinged
panels are hinged to fixed container.
17. SUPPORT BRACES. Provides support to hinged sidewall during expandingprocedures only.
18. CLOSEOUT PANELS. Used to cover openings in endwalls and sidewalls.
1-9. EQUIPMENT DATA.
Exterior Dimensions (Stowed Shelter)
Width. . . . . . . . . . . . . . .
Height. . . . . . . . . . . . . . . .
Length. . .. .. . . . . . . .
Exterior Dimensions (Expanded Shelter)Width. . . . . . . . . . . .
Height. . . . .. . . . . . . . .
Length. . . .. . . .. . .. . .
Interior Dimensions
Minimum clear height . . . . . . . .
Minimum clear width (stowed mode) .Usable floor space . . . . . . . . .
Total Weights
Less payload . . . . . . . . . . . .
With payload (maximum) . . . . . . .
Primary Power Requirements
NQOB Model . . . . . . . . . . . . .
NQOD Model . . . . . . . . . . . . .
Environmental Limits
Operating temperature . . . . . . .
Transportability (Stowed Shelter)
ISO fittings . . . . . . . . . . . .
Dolly Set . . . . . . . . . . . . .
Fork Lift . . . . . . . . . . . . .
8 ft. (2.44 meters)
8 ft. (2.44 meters)
l9 ft., 10-1/2 i. (6.05 meters)
21 ft., 9 in. (6.63 meters)
8 ft., (2.44 meters)
19 ft., 10-1/2 in. (6.05 maters)
80.29 in. (2.04 meters)
77.78 in. (1.98 meters)
400 sq. ft. (37.2 sq. meters)
6,900 lbs. (3130 kg)
15,000 lbs. (6804 kg)
120/208 Vat, 60 Hz, 3 phase, 4 wire with
1 grid.
120/208 Vac, 60 Hz, 3 phase, 4 wire with4 grids.
-65F to +125F (-53.9C to 51.7C)
Provided with upper and lower IS0
fittings in accordance with specifica-tion IS0 1496/1.
Equipped with mobilizer fittings fortransportation with mobilizer. Model
No. M832- 10,000 pounds (4546 Kg)
maximum capacity (TM 9-2330-275-14&P).
Model No. M1022 15,000 pounds (6804 Kg)
maximum capacity (TN 9-2330-379-14&P).
Built-in fork lift provisions.
1-6 CHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
33/349
TM 10-5411-200-1T.O. 35E4-177-
CHAPTER 2
OPERATING INSTRUCTIONS
Section I. DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS
2-1. SCOPE. This section provides description and use of operator controls and indicators needed to operatshelter. This section provides descriptions for circuit breaker panel controls and indicators (See paragraph 2-and personnel end panel mounted controls and indicators (See paragraph 2-3).
INSIDE VIEW - LOOKING AT PERSONNEL END PANEL
CHANGE 8 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
34/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
35/349
TM 10-5411-200-T.O. 35E4-177
2-2. (cont)
Control or Indicator Function
6 Circuit breaker Provides overload protection for interior utility outletsmounted on sidewall.
7 Circuit breaker Provides overload protection for ground fault inter-
rupter utility outlet mounted on power entry panel.8 Circuit breaker Provides overload protection for interior utility outlets
mounted on hinged sidewall and hinged endwalls.
9 Circuit breaker Provides overload protection for interior utility outletmounted on hinaed sidewall and hinged endwalls.
2-3. PERSONNEL END PANEL MOUNTED CONTROLS AND INDICATORS
Control or Indicator Function
1 Door activated blackout switch During blackout conditions it turns off all lights inshelter when fixed end personnel door is opened.To override operation of this switch, the circuit breaer panel mounted blackout override switch must bein ON position. Circuit protected against overload bcircuit breaker.
2 Ceiling lights switch In ON position, turns on nine fluorescent lights inshelter. In OFF position turns off all fluorescentlights. Circuit protected against overload by circuitbreaker.
CHANGE 8
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
36/349
TM 10-5411-200-14T.O. 35E4-177-1
Section II OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS.)
2-4. GENERAL. For the shelter to be ready for use at al l t imes, i t must beinspected systematically so that defects may be discovered and correctedbefore they result in serious damage or fai lure.
Before you operate. Always keep in mind the CAUTIONS and WARNINGS.
Perform your "B-before" PMCS (Table 2-1).
b. While you operate. Always keep in mind the CAUTIONS and WARNINGS.
Perform your "D-during" PMCS (Table 2-1).
c . Monthly. Always keep in mind the CAUTIONS and WARNINGS. Perform
your "M-monthly" PMCS (Table 2-1).
d. I f your equipment fa i ls to operate, troubleshoot with proper equip-ment. Repor t def ic ienc ies as fo l lows:
(1) (A) Users report in accordance with DA PAM 738-750.
(2) (P) Users refer to appl icable inspection manuals and work cardsets in the TO 35C2-3 series for periodic requirements and the PMCS Table fordetai led procedures.
2-5. SPECIAL INSTRUCTIONS. The fol lowing actions apply while performing yourPMCS:
a . Stop operation immediately i f deficiency is noted during operationwhich would damage the equipment.
b . Defects discovered during operation of the equipment should be notedfor future correction to be made as soon as operation has ceased.
2-6. PREVENTIVE MAINTENANCE CHECKS AND SERVICES TABLE. Tab l e 2 - 1 l i s t s a l lPMCS to be performed by the operator.
NOTE
I f the equipment must be kept in continuous operation,check and service only those items that can be checkedand serv iced wi thout d is turb ing operat ion. Make thecomplete checks and services when the equipment can beshut down. Inspect shel ter for leaks.
2-4
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
37/349
TM 10-5411-200-1
T.O. 35E4-177-
For Readiness
Procedures reporting,
Check for and have re- equipment is
Item Interval Item to be paired or adjusted as Not Ready/
No. B D M Inspected necessary Available if:
I I
ELECTRICAL SYSTEM
1 q q q Circuit breaker Inspect for damage to Circuit panel
panel assembly door and panel damaged
2 q q q Panel wiring Inspect for damage or Wiring damaged
disconnection or disconnected
3 q q q Light switches Inspect for operation Lights not
operating
4 q q q Circuit breakers Inspect for operation, Circuit breakers
condition, and security not operating
5 q q q Power entry Inspect for damage to Panel damaged
panel assembly panel
6 q q q Receptacles Inspect for operation, Receptacles not
condition, and security operating
7 q q q Terminals/ Inspect for operation, Terminals/con-
Connectors condition, and security nectors not
operating
8 q q q Area light Inspect for operation Light not
assembly operating
9 q q q Incandescent Inspect for operation Light not
light assembly operating
10 q q q Hinged roof Inspect for operation Lights not
area ceiling operating
lights
11 q q q Fixed roof area Inspect for operation Lights not
ceiling lights operating
12 q q q Receptacle Inspect for operation Outlets not
outlets operating
Table 2-1. Operators Preventive Maintenance Checks and Services
B - Before D - During M - Monthly
2-
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
38/349
TM 10-5411-200-14
T.O. 35E4-177-1
Table 2-1. Operators Preventive Maintenance Checks and Services (cent)
B - Before D - During M - Monthly
For Readiness
Procedures reporting,
Check for and have re- equipment is
Item Interval Item to be paired or adjusted as Not Ready/No. B D M Inspected necessary Available if:
13 q q q Wall switches Inspect for operation Switches not
operating
14 q q q Blackout switch Inspect for operation Switch not
operating
15 q q q Wiring Inspect for damage or Wiring damaged
disconnection or disconnected
DOOR ASSEMBLIES
16 q q Personnel and Inspect for operation, Door not operat-
right cargo condition and security ing, damaged,
door or insecure
17 q q Door vent Inspect for operation Vent not operat-
and condition ing or damaged
18 q q Door lock Inspect for operation Lock assembly
assembly and condition not operating or
damaged
19 q q Door stop Inspect for operation Stop assembly
assembly and condition not operating ordamaged
20 q q Left cargo Inspect for operation Door not operat-door condition, and security ing, damaged, or
insecure
21 q q Foot bolt Inspect for operation Foot bolt
assembly and condition assembly not
operating or
damaged
22 q q Chain bolt Inspect for operation Chain bolt
assembly and condition. assembly notoperating or
damaged
2-6
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
39/349
TM 10-5411-200-14
T.O. 35E4-177-1
Table 2-1. Operators Preventive Maintenance Checks and Services (cont)
B - Before D - During M - Monthly
For Readiness
Procedures reporting,
Check for and have re- equipment is
Item Interval Item to be paired or adjusted as Not Ready/
No. B D M Inspected necessary Available if:
I
HINGED PANEL LEVELING JACK ASSEMBLIES
23 q q Hinged panel a. Inspect for sinking a. Shelter not
leveling jack into ground if shel- level
assemblies ter not level (check
frequently during
rainy conditions).
b. Inspect for condi- b. Jacks damaged
tion and security or insecure
HINGED PANEL ASSEMBLIES24 q q Hinged roof Inspect skin surface for Panel skin
panels paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
25 q q Support strut Inspect for operation Support strut
assemblies and condition assemblies not
operating or
damaged
26 q q Hinged endwall Inspect skin surface for Panel skin
paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
27 q q Endwall close- Inspect skin surface for Panel skin
out panel paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
28 q q Latches Inspect for operation Latches not
and condition operating ordamaged
29 q q Hinged side- Inspect skin surface for Panel skinwalls paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
2-7
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
40/349
TM 10-5411-200-14
T.O. 35E4-177-1
Table 2-1. Operators Preventive Maintenance Checks and Services (cont)
B - Before D - During M - Monthly
For Readiness
Procedures reporting,
Check for and have re- equipment is
Item Interval Item to be paired or adjusted as Not Ready/No. B D M Inspected necessary Available if:
30 q q Sidewall close- Inspect skin surface for Panel skin
out panels paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
31 q q ECU intake Inspect skin surface for Panel skin
panel paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
32 q q ECU return Inspect skin surface for Panel skinpanel paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
33 q q Hinged floor Inspect skin surface for Panel skin
panel paint damage, corrosion, corroded,
cracks, or punctures cracked, or
punctured
CONTAINER LIFT JACK ASSEMBLIES
34 q q q Container lift a. Inspect for sinking a. Shelter notjack assemblies into ground if shel- level
ter not level (check
frequently during
rainy conditions).
b. Inspect for condi- b. Jacks damagedtion and security or insecure
FIXED PANEL ASSEMBLIES
35 q q Personnel door a. Inspect skin surface a. Panel skinend endwall for paint damage, corroded,panel corrosion, cracks, or cracked, or
punctures punctured
b. Inspect security of b. Upper mobili-
upper mobilizer fit- zer fittingting insecure
36 q q Level assembly Inspect for condition Level assembly
and security damaged or in-
secure
2-8
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
41/349
TM 10-5411-200-14
T.O. 35E4-177-1
Table 2-1. Operators Preventive Maintenance Checks and Services (cont)
B - Before D - During M - Monthly
B
For readiness
Procedures reporting,
Check for and have re- equipment isItem Interval Item to be repaired or adjusted as Not Ready/
No. D M Inspected necessary Available if:
37 l l Folding step Inspect for condition Folding step
and security damaged or in-
secure
38 . l Cargo door end a. Inspect skin surface a. Panel skin
endwall panel for paint damage, corroded,
corrosion, cracks, cracked, or
or punctures punctured
b. Inspect security of b. Upper mobili-upper mobilizer zer fittings
fittings insecure
39 l l Roof panel a. Inspect skin surface a. Panel skin
for paint damage, corroded,
corrosion, cracks, cracked, or
or punctures punctured
b. Inspect roof hand b. Hand hold
hold for condition damaged or
and security insecure
c. Inspect strike plates c. Strike plate
for security and loose or
condition damaged
40 l l Load balancer Inspect for operation, Load balancer
and cable condition, and security and cable
assembly assembly not
operating,
damaged, or
insecure
41 l l Stowage Inspect for condition Stowage brackets
brackets and security damaged or in-
secure
42 l l Solar bar Inspect for operation, Solar barassembly condition, and security assembly not
operating,
damaged or
insecure
CHANGE 2 2-9
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
42/349
TM 10-5411-200-14
T.O. 35E4-177-1
Table 2-1. Operators Preventive Maintenance Checks and Services (cent)
B - Before D - During M - Monthly
B D
For readiness
Procedures reporting,
Check for and have re- equipment isItem Interval Item to be repaired or adjusted as Not Ready/
No. H Inspected necessary Available if:
43 q q Floor panel Inspect skin surface Panel skin
for paint damage, cor- corroded,
rosion, cracks, or cracked, or
punctures punctured
FRAME ASSEMBLY
44 q q Corner post Inspect for condition Corner post or
and IS0 fit- and security IS0 fittingting assembly damaged or in-
secure
45 q q Camlock and Inspect for operation, Camlock or latch
latch cam condition, and security cam handle not
handle operating,damaged, or in-
secure
MISCELLANEOUS COMPONENTS
46 q q Equipment con- Inspect for condition Equipment con-
tainer and completeness tainer damaged
or incomplete
47 q q storm Inspect for condition Storm configura
configuration and completeness tion components
components damaged or in-
complete
48 l l Support braces Inspect for condition Support braces
damaged
49 q q Leveling jack Inspect for condition Leveling jack
extensions extensions
damaged
Skin surfaces that are punctured/damaged will allow
water entry into honeycomb panel. All punctures/holes of damaged areas must be covered immediately
pending permanent repair.
C A U T I O N
2-10 CHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
43/349
TM 10-5411-200-14
T.O. 35E4-177-1
Section III. SETUP OF SHELTER
2-7. PREPARATION FOR USE.
Select a site that:
q Has reasonable maneuvering area for vehicles that will be used for haulingor hoisting shelter.
q The terrain is firm, well drained, and relatively free of surface rocks or
stones.
q The slope of the terrain does not exceed 18 inches (45.7 cm) over the
projected floor area of the expanded shelter.
2-8. SHELTER INVENTORY CHECKS.
a. Expandable shelters are shipped uncrated.
b. Inspect shelter for damage incurred during shipment. If shelter hasbeen damaged, report damage on SF361, Transportation Discrepancy Report.
Check equipment against packing list to see if shipment is complete.Report all discrepancies in accordance with instructions of DA PAM 738-750.
d. Inspect shelter (stowed mode) in accordance with paragraph 2-9.
2-9. SHELTER INSPECTION CHECKLIST
LOCATION ITEM ACTION
1. Fixed personnel a.endwall
b.
co
Power entry panel Inspect connectors for
damage.
Identification and Check for legibility orinstruction plates missing plates.
Personnel door Check for security and
condition of door, locks,
seals, and vent.
CHANGE 2 2-11
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
44/349
TM 10-5411-200-14
T.0. 35E4-177-1
2-9. (cont)
LOCATION ITEM ACTION
2. Fixed roof
3. Fixed cargoendwall
4. Hinged floors
d.
e.
f.
g.
a.
b.
c.
d.
a.
b.
c.
d.
e.
Upper mobilizer
fittings
Folding steps
Components
Skin
Roof handhold
Upper IS0 fittings
Skin
Strike plates
CSC Plate
Doors
Upper mobilizer
fittings
Components
Skin
Skin
Check for security and
condition.
Check for security and
condition.
Inspect for missing, bent,
or damaged components.
Inspect skin surface for
paint damage, corrosion,
cracks, or punctures.
Check for security and
operation.
Inspect fittings for damage.
Inspect skin surface for
paint damage, corrosion,
cracks, or punctures.
Check for security and
condition.
Check for legibility ormissing plate.
Check for security and con-dition of doors, locks,
seals, and vents.
Check for security and
condition.
Inspect for missing, bent,
or damaged components.
Inspect skin surface for
paint damage, corrosion,
cracks, or punctures.
Inspect skin surface for
paint damage, corrosion,
cracks, or punctures.
2-12 CHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
45/349
TM 10-5411-200-14
T.O. 35E4-177-1
2-9. (cont)
LOCATION ITEM ACTION
5. Fixed floor base a. Lower mobilizer Check for security and
frame fittings condition.
b. Lower ISO fittings Inspect fittings for damage.
c. Frame edge and Inspect for damage.
fork lift opening
6. Corner posts Components Inspect for missing, bent,
or damaged components.
2-10. SHELTER HANDLING
Do not use handling equipment with capacity of less
than gross weight of system. Do not allow shelter
to swing back and forth when suspended. Failure to
observe this WARNING may result in damage to equipment
or severe injury or death to personnel.
NOTE
Dollyset M832 mobilizer used only if gross weight of
shelter system is 10,000 pounds (4546 Kg) or less.
Dollyset XM1022 or hoisting sling (with cable breaking
strength of 35,000 pounds) used if gross weight of shelter
system is over 10,000 pounds (4546 kg).
When using fork lift, make sure it has a minimum tine
length of six feet. Use inner slots for fork liftingan empty shelter only.
Use 20-foot container lift sling (bottom lift, type II,
with a 20 long ton safe working load) with aluminum
spreader, Appendix D.
2-13
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
46/349
TM 10-5411-200-14
T.O. 35E4-177-1
2-10. (cont)
SHACKLE Attachment
a. Hoisting from upper ISO fittings.
CAUTION
Do not attach hoisting sling or ISO lifting device
to handling equipment in such a manner that angle
between hoist line and shelter is less than 45
degrees. Any angle less than 45 degrees will cause
an excessive strain which could damage shelter.
(1) Attach hoisting Sling to crane or equivalent and four upper IS0fittings.
(2) Hoist shelter and position to desired location.
b. Hoisting from lower IS0 fittings.
(1) Attach IS0 lifting device to crane or equivalent and four lowerIS0 fittings.
(2) The IS0 lifting device should contact four lower IS0 fittings only
and not make any other contact with shelter.
2-14 CHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
47/349
TM 10-5411-200-14
T.O. 35E4-177-I
2-10, (cont)
(3) Terminal fittings shall be installed so that lifting forces are
exerted not more than 1-1/2 in. (38 mm) away from ISO fittings.
(4) Hoist shelter and position to desired location.
c. Fork lifting from fork lift slots in base frame.
(1) Fork lift arms shall be at least 6 ft (1.8 m) long.
(2) Use care when inserting fork lift arms in fork lift slots.
(3) Use inner slots for fork lifting an empty shelter only.
(4) Use outer slots for fork lifting shelter with maximum payload.
d. Dollyset lifting from mobilizer fittings.
(1) Separate Dollyset sections and prepare for use observing allrecommendations of Dollyset technical manual.
(2) Position. Dollyset sections at ends of shelter adjacent tomobilizer fittings at shelter endwalls.
(3) Position Dollyset brackets to connect with shelter mobilizerfittings and secure Dollyset to shelter.
2-15
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
48/349
TM 10-5411-200-14
T.O. 35E4-177-1
2-10. (cont)
(4) Operate Dollyset according to Dollyset technical manual to
raise shelter to towing height.
(5) Connect towing equipment to Dollyset tow bar.
(6) When shelter is in desired position, operate Dollyset to lower
shelter and remove Dollyset sections.
e. Dollyset lifting from ISO fittings.
(1) Separate Dollyset sections and prepare for use observing all
recommendations of Dollyset technical manual.
(2) Position Dollyset sections at ends of shelter adjacent to ISO
fittings at shelter endwalls.
(3) Position Dollyset brackets to connect with shelter IS0 fittings
and secure Dollyset to shelter.
(4) Operate Dollyset according to Dollyset technical manual to
raise shelter to towing height.
(5) Connect towing equipment to Dollyset tow bar.
(6) When shelter is in desired position, operate Dollyset to lower
shelter and remove Dollyset sections.
f. Trailer or flatbed transporting.
(1) Using four 14-foot chains and four binders, secure shelter to
trailer or flatbed as shown in method 1.
(2) Using two 20-foot chains and two binders or four 6-foot chains
and two binders, secure shelter to trailer or flatbed as shown in method 2.
2-16
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
49/349
TM 10-5411-200-14T.O. 35E4-177-1
2 - 1 0 . ( c o n t )
g. Rai l road t ranspor t ing.
(1) P lace f loor t imbers a long the f ront and rear o f the shel tercontac t ing lower ISO f i t t ings .
NOTE
Make sure timber is new and has no structuralweakness.
(2) Tie the shelter down to the retaining brackets on the rai lroadcar with 1/2-inch diameter wire rope and turn buckles.
(3) Place 8 inch by 8 inch blocking t imbers on the rai lroad car f loorwi th the edge gra in la id f la twise.
(4) P lace at leas t four 4 inch by 5 inch ver t ica l post t imbers wi thedge grain oriented fore and aft at each end of the shelter.
(5) Bol t the ends of the f loor t imbers to the ver t ica l post t imbersusing 3/4-inch diameter bolts.
(6) Spike or na i l the ver t ica l post t imbers through the re ta in ingbrackets on the rai lroad car to prevent vert ical movement.
2-17
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
50/349
5411-01-136-9838PART NO: 5-4 3118
81337
5411-01-136-9838
81337PART NO: 5-4-3201
5411-01-294-9866
5411-01-294-9866
M 10-5411-200-14.O. 35E4-177-1
-11. LOCATION OF IDENTIFICATION AND INSTRUCTION PLATES. The following figures provide location andontents of identification and instruction plates for the shelter.
-18 CHANGE 8
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
51/349
TM 10-5411-200T.O. 35E4-17
2-11. LOCATION OF IDENTlFlCATlON AND INSTRUCTION PLATES. (Cont)
Sand Paint Data Plate (with scuff strip)
THIS SHELTER PAINTED WITH CARC PAINTPAINT
TYPE
MIL SPEC
COLOR
COLOR CODE
FED-STD-595INTERIORPAINT
EXTERIORPAINT
EPOXY MIL-C-22750 17925WHITE
ALIPHATICPOLYURETHANE
MIL-C-46168 33303SAND
PRIMER EPOXY MIL-P-53022
FLOORPAINT
WALKWAYCOMPOUND
MIL-W-5044TYPE I GRAY
26251
FLOOR
PAINT
WALKWAY MIL-W-5044
COMPOUND TYPE II GRAY
Location of Identification and Instruction Plates
26251
Sand Paint Data Plate (without scuff strip)
THIS SHELTER PAINTED WITH CARC PAINT
INTERIOR
PAINT
EXTERIORPAINT
PRIMER
FLOORPAINT
PAINTTYPE
EPOXY
ALIPHATICPOLYURETHANE
EPOXY
WALKWAYCOMPOUND
MIL SPECCOLOR
COLOR CODEFED-STD-595
MIL-C-22750 17925
WHITE
MIL-C-46168 33303SAND
MIL-P-53022
MIL-W-5044TYPE I GRAY
26251
Location of Identification and Instruction Plates
CHANGE 8 2-
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
52/349
TM 10-5411-200-14T.O.35E4-177-1
2-11. LOCATION OF IDENTIFICATION AND INSTRUCTION PLATES. (Cont)
Camouflage Paint Data Plate (with scuff strip)
THIS SHELTER PAINTED WITH CARC PAINT
INTERIORPAINT
EXTERIORPAINT
PRIMER
FLOOR
PAINT
FLOORPAINT
PAINTTYPE
EPOXY
ALIPHATICPOLYURETHANE
E P OX Y
WALKWAY
COMPOUND
WALKWAYCOMPOUND
MIL SPECCOLOR
MIL-G22750GLOSS WHlTE
MlL-C-46168GREEN 383BROWN 383BLACK
MIL-P-53022
MIL-W-5044
TYPE I GRAY
MIL-W-5044TYPE II GRAY
COLOR CODEFED-STD-595
17925
340943005137030
26251
26251
Camouflage Paint Date Plate (without scuff strip)
THIS SHELTER PAINTED WITH
CARCPAINT
PAINT MIL SPEC COLOR CODETYPE COLOR FED-STD-595
INTERIOR EPOXY MIL-C-22750 17925PAIN-ILL WHITE
EXTERIORPAINT
ALIPHATICPOLYURETHANE
MIL-C-46168GREEN 383 34094BROWN 383 30051BLACK 37030
PRIMER EPOXY MIL-P-53022
FLOOR WALKWAY MIL-00-5044 26251P A I N T COMPOUND TYPE I GRAY
-18.2 CHANGE 8
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
53/349
TM 10-5411-200-1T.O. 35E4-177-
2-11. LOCATION OF IDENTIFICATION AND INSTRUCTION PLATES. (Cont)
Green Paint Data Plate (with scuff strip)
THIS SHELTER PAINTED WITH CARC PAINT
INTERIORPAINT
EXTERIORPAINT
PRIMER
FLOORPAINT
FLOORPAINT
PAINTTYPE
EPOXY
ALIPHATICPOLYURETHANE
EPOXY
WALKWAYCOMPOUND
WALKWAYCOMPOUND
MIL SPECCOLOR
MIL-C-22750WHITE
MIL-C-46168GREEN 383
MIL-P-53022
MIL-W-5044TYPE I GRAY
MIL-W-5044NPE II GRAY
COLOR CODEFED-STD-595
17925
34094
26251
26251
Green Paint Data Plate (without scuff strip)
THIS SHELTER PAINTED WITH CARC PAINT
INTERIORPAINT
EXTERIORPAINT
PRIMER
PAINTTYPE
EPOXY
ALIPHATICPOLYURETHANE
EPOXY
MIL SPECCOLOR
MIL-C-22750WHITE
MIL-C-46168GREEN 383
MIL-P-53022TYPE I
COLOR CODEFED-STD-595
17925
34094
FLOOR WALKWAY MIL-W-5044PAINT COMPOUND TYPE I GRAY
26251
CHANGE 8 2-18.3/(2-18.4 blan
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
54/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
55/349
TM10-5411-200-14T.O. 35E4-177-1
2-11. (cont )
ERECTION SEQUENCE
THE SHELTER JACKS ARE REMOVED FROM THEIR STOWED SLIDE THE HINGED-ROOF OUTWARD WITH SOLAR BALOCATION AND ATTACHED TO THE FOUR CORNERS RAISE PARTIALLY TO PROVIDE ACCESS TO THEOF THE MODULE. ROOF STRUTS STOWED ON THE INSIDE OF THE
THE MODULE IS LEVELED USING THE BULLS EYE LEVELSLOCATED NEAR THE JACKS.
HINGED ROOFLOWER AND PIN ROOF STRUTS
REMOVE CABLE RETAINING PINS INSIDE SHELTER. DlSENGAGE RAISE THE HINGED ROOF AND REST ON ROOF STRUT
EXTERNAL FLOOR LOCKS AND USE LOCKING MECHANISM SWING THE HINGED ENDWALLS OUT TO THE OPENTO FREE FLOOR ENGAGEMENT POSITION
LOWER THE FLOOR TO THE EXTENT OF THE CABLE TRAVEL (1 1/2"BELOW LEVELS)
RAISE THE HINGED SIDEWALL ANDCONNECT 2 SUPPORT BRACES.INSTALL 2 SUPPORT JACKS.
USING THE SUPPORT JACKS, RAISE THE HINGED FLOOR ANDSlDEWALL TO MATE THE HINGED ENDWALLS. LINE UPPOSITIONING MARKS.
REMOVE THE STRUTS FROM THE UPRIGHT POSITION ALLOWINGTHE HINGED ROOF TO REST ON THE HINGED SIDEWALL ANDENDWALLS
REPEAT SEQUENCE FOR OPPOSITE SIDE. STOW THE STRUTS ON THE HINGED ROOF. ENGAGE ALLPANEL LATCHES TO COMPRESS THE SEALS.
L o c a t i o n o f I d e n t i f i c a t i o n a n d I n s t r u c t i o n P l a t e s
2-19
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
56/349
TM 10-5411-200-14T.O. 35E4-177-1
2-12. SHELTER EXPANSION
NOTE
Four personnel are required to perform the following
procedures.
a. Remove four container lift jacks from inside of personnel and right
cargo doors by turning locking handle to loosen jack attachment insert and
removing safety pin.
b. Position jacks at each corner of shelter.
NOTE
Stencil on jack indicates handle rotation to raise orlower jack.
c. Rotate handle to raise jack until insert will enter lower ISO
fitting and upper jack attachment engages jack support bracket On corner
post .
d. Turn locking handle to rotate insert in ISO fitting. Install safety
pin.
e. Repeat steps c and d at three remaining corner posts.
2-20
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
57/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4
T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 2 . ( c o n t )
f . Ra i s e a l l j a c k s s i mu l t a n eo us l y a t e a c h c o r n e r o f s h e l t e r t o p r e v e n te x c e s s i v e s t r a i n o n j a c k s o r s h e l t e r .
NOTE
T h e s h e l t e r s h a l l b e r a i s e d a mi n i mu m o f 3i n c h e s ( 7 . 6 c m) o f f g r o u nd .
g . Wa t c h l e v e l i n d i c a t o r s a t e a c h c o r n e r a n d a d j u s t j a c k s a s n e e d e d i no r d e r t o l e v e l s h e l t e r .
h . Re mo v e q u i c k r e l e a s e p i n s f r o m s t o p p l a t e s o n b o t h l o a d b a l a n c e r s( i n s i d e s h e l t e r ) o f t h e s i d e o f t h e s h e l t e r b e i n g e x p a n de d t o p e r mi t s u p p o r tc a b l e t r a v e l .
ST O P PL AT EWI T H OU I C KR EL E A S E P I N
2 - 2 1
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
58/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 2 . ( c o n t )
WA R N I N G
Ex p a n d a b l e s e c t i o n ( h i n g e d f l o o r a n d h i n g e d s i d e wa l l
t o g e t h e r ) we i g h s 7 0 0 p o u n d s ( 3 1 8 k g ) . Do n o t s t a n dd i r e c t l y i n f r o n t o f h i n g e d s e c t i o n .
i . Ra i s e c a m l o c k h a n d l e s o n c o r n e r p o s t s a n d r o t a t e a s i n d i c a t e d t od i s e n g a g e h i n ge d f l o o r l o c k s .
Ca r e f u l l y l o we r h i n g e d f l o o r t o t h e e x t e n t o f s u p p o r t c a b l e t r a v e l( 1 - 1 / 2 i n . ( 3 . 8 c m) b e l o w l e v e l ) .
W A R N I N G
T h e s t o p p l a t e c a b l e a s s e mb l y i s a s p r i n g p o we r e dme c h a n i s m. Pe r s o n a l i n j u r y o r d ea t h ma y r e s u l t i f
t wo qu i c k r e l e a s e p i n s a r e no t i n s t a l l e d i n t h es t o p p l a t e s .
k . I n s t a l l . t wo qu i c k r e l e a s e p i n s i n s t o p p l a t e s o n l o a d b a l a n c e r s( i n s i d e s h e l t e r ) t o p r e v e n t r e t u r n o f s u p po r t c a b l e .
l . Re mo v e t wo s u p p o r t b r a c e s f r o m e q u i p me n t c o n t a i n e r .
m. Ra i s e h i n g e d s i d e wa l l a n d h o l d i n p o s i t i o n .
n . I n s t a l l t h e t wo s u p p o r t b r a c e s i n b r a c e c u p s o n h i n g e d f l o o r a n ds i d ewa l l b e h i n d s u p p o r t c a b l e .
o . Re mo v e t wo l e v e l i n g j a c k s f r o m i n s i d e o f l e f t c a r g o d o o r .
p . Po s i t i o n j a c k s a t e a c h c o r n e r o f e x p a n d e d s i d e .
2 - 2 2 C HA NGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
59/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
60/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 2 . ( c o n t )
WA R N I N G
2 - 1 2 .
Do o r v e n t s a r e s p r i n g l o a d e d t o s wi n g u p wa r d . T o p r e v e n t i n j u r y ,h o l d d o o r v e n t s h u t wh i l e u n l a t c h i n g a l l t h e r e t a i n i n g c l i p s .
( c o n t )
t . P u s h t w o h a n d l e s o f s o l a r b a r o n i n s i d e o f f i x e d r o o f t o t h e i r e x t e n t s i mu l t a n e o u s l y t o s l i d eh i n g e d r o o f o u t wa r d ,
C A U T I O N
S u p p o r t i n n e r t u b e wh i l e d i s e n g a g i n g s u p p o r t s t r u t s f r o m s t o wa g e b r a c k e t s .
u . P u l l l o c k p i n t o f r e e s u p p o r t s t r u t s f r o m s t o wa g e b r a c k e t a n d s wi n g do wn wa r d ,
2 - 2 4 C h a n g e 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
61/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 2 . ( c o n t )
v . E x t e n d
a r e i n a l i g n m e n t .
i n ne r t u ba o f s t r u t a n d i n s e r t l o c k p i n wh e n p i n ho l e s i n i n n e r t u b e an d o u t e r t u b
C A U T I O N
Do n o t f o r c e h i n ge d r o o f t o f u l l h e i g h t . T h i s c o u l d c au s e d a ma ge t o t h er o o f a n d s i d e wa l l s e a l . E n s u r e t h a t t h e h i n g e d r o o f w i l l c l e a r t h e h i n g e ds i d e we l l p r i o r t o l i f t i n g .
w. Ra i s e h i n g e d r o o f t o f u l l h e i g h t o f s t r u t s u s i n g a l l f o u r p e r s o n n e l : T wo o n s u p p o r t s t r u t s ; t wt o a s s i s t a t r o o f .
C h a n g e 2 2 - 2 4 . 1 / ( 2 - 2 4 . 2 b l a n k
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
62/349
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
63/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 2 . ( c o n t )
x . Swi n g h i n g e d e n d wa l l s o u t t o o p e n p o s i t i o n .
y . Ro t a t e h a n d l e s t o r a i s e b o t h j a c k s u n t i l p o s i t i o n i n g ma r k s o n h i n g e de n d wa l l s a n d h i n g e d s i d e wa l l a r e i n a l i g n me n t .
C A U T I O N
DO n o t c o n t i n u e t o j a c k s i n c e t h i s ma y c a u s es t r u c t u r a l d a ma g e t o h i n g e d e n d wa l l .
z . Us e s u p p o r t s t r u t s t o l o we r h i n g e d r o o f t o r e s t o n h i n g e d e n d wa l l sa n d s i d e wa l l .
a a . Re mo v e l o c k p i n s f r o m s u p p o r t
s t r u t s . Co mp r e s s s u p p o r t s t r u t s a n ds e c u r e i n s t o wa g e b r a c k e t s o n h i n g e dr o o f wi t h l o c k p i n s .
a b . A d j u s t l e v e l i n g j a c k t o ma k e s u r ep o s i t i o n i n g ma r k s o n h i n g e d r o o f a n d h i n g e ds i d e wa l l a r e p r o p e r l y a l i g n e d .
a c . Ob t a i n f o u r r e mo v a b l e l a t c h e s f r o me q u i p me n t c o n t a i n e r a n d i n s t a l l t wo o n h i n g e ds i d e wa l l a n d t wo o n h i n g e d e n d wa l l s .
a d . E n g a g e a l l p a n e l l a t c h e s t o c o mp r e s s
s e a l s . E n g a g e n o n r e mo v a b l e l a t c h e s f i r s t t h e nr e mo v a b l e l a t c h e s .
a e . V i s u a l l y c h e c k t o ma k e s u r e a l l s e a l sa r e p r o p e r l y c o mp r e s s e d .
a f . Re mo v e s u p p o r t b r a c e s .
a g . Re p e a t s t e p s h t h r o u g h a f t o e x t e n do t h e r e x p a n d a b l e s i d e , t h e n s t o w s u p p o r t b r a c e si n e q u i p me n t c o n t a i n e r .
2 - 2 5
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
64/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E 4 - 1 7 7 - 1
2 - 1 3 . CE I L I NG L I GHT S AND UT I L I T Y OUT L E T S I NS TA L L A T I ON
a . Ce i l i n g l i g h t i n s t a l l a t i o n .
W A R N IN G
I n t h e e v e n t o f l a mp b r e a k a g e , c a r e mu s t b e t a k e n i nr e mo v a l o f b r o k e n g l a s s f r a g me n t s a n d wh i t e p h o s p h o r o u sd u s t t h a t ma y b e d i s p e r s e d wi t h i n f i x t u r e . I n h a l a t i o no f p h o s ph o r o u s d u s t c o u l d c a us e d an g e r o u s I n j u r y .
( 1 ) S e t c i r c u i t b r e a k e r C B 6 t o o f f p o s i t i o n .
( 2 ) R e mo v e p o we r c o r d f r o m s t o wa g e c l i p o n c e i l i n g .
( 3 ) De p r e s s p l u n g e r l o c k i n f i x e d r o o f l i g h t s t o wa g e b r a c k e t .
( 4 ) Mo v e e n t i r e l i g h t f i x t u r e l e n g t h wi s e t o wa r d p o we r c o r d e n d t od i s e n g a g e l i g h t f r o m t h e f o u r c a p t i v e s t u d s i n f i x e d r o o f .
( 5 ) Mo v e l i g h t f i x t u r e i n t o e x p a n d a b l e s e c t i o n a n d ma t e w i t h f o u rc a p t i v e s t u ds i n h i n g e d r o o f .
( 6 ) A f t e r c e i l i n g l i g h t i s p r o p e r l y s e a t e d , s e c u r e f i x t u r e b ymo v i n g u n t i l s p r i n g l o a d e d p l u n g e r e n g a g e s .
( 7 ) P l u g p o we r c o r d i n t o c o n n e c t o r , a n d t wi s t o n e - q u a r t e r t u r n t o
l o c k i n .
( 8 ) Re p e a t t h i s p r o c e d u r e f o r e a c h o f f i v e r e ma i n i n g c e i l i n gl i g h t s .
b . Ca b l e a n d r e c e p t a c l e a s s e mb l y i n s t a l l a t i o n .
2 - 2 6
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
65/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 3 . ( c o n t )
( 1 ) R e l e a s e c a p t i v e f a s t e n e r s a n d r e p o s i t i o n r e c e p t a c l e s f r o ms t o we d p o s i t i o n o n h i n g e d e n d wa l l t o o p e r a t i n g p o s i t i o n o n h i n g e d e n d wa l l s a n dh i n ge d s i d ewa l l s .
( 2 ) P o s i t i o n r e c e p t a c l e s wi t h p o we r c o r d s f a c i n g u p .
( 3 ) S e c u r e f l e x i b l e c a b l e wi t h v e l c r o s t r a p s .
2 - 1 4 . A RE A L I GHT I NS T AL L A T I ONa . L o o s e n wi n g n u t s a n d r e mo v e a r e a l i g h t f r o m s t o wa g e l o c a t i o n i n s i d es h e l t e r o n p e r s o n n e l e n d p a n e l .
D o n o t
NOTE
r e mo v e wi n g n u t s f r o m s c r e ws .
2 - 2 7
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
66/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 4 . ( c o n t )
b . Re mo v e b u l b f r o m e q u i p me n t c o n t a i n e r a n d s c r e w b u l b i n t o l i g h ts o c k e t .
c . I n s t a l l t h e a r e a l i g h t o n t h e f i x e d p e r s o n n e l o r c a r g o e n d wa l l b yma t i n g t h e h e a d e d e n d o f t h e mo u n t i n g s c r e ws wi t h t h e b r a c k e t s p r o v i d e d .
d . Se c u r e t h e a r e a l i g h t t o t h e mo u n t i n g b r a c k e t s b y t i g h t e n i n g t h e t wowi n g n u t s .
NOTE
Wh e n t h e a r e a l i g h t i s i n s t a l l e d a t c a r g o e n d o fs h e l t e r t h e c a b l e i s r o u t e d o v e r t h e t o p o f t h es h e l t e r . T h e e x c e s s c a b l e s l a c k s h o u l d b e n e a t l y
c o i l e d o n t h e a r e a l i g h t p o s t s o t h a t i t d o e s n o tp r e s e n t a h a z a r d t o p e r s o n n e l .
e . Co n n e c t c a b l e i n t o J 3 o r J 4 c o n n e c t o r s o n t h e p o we r e n t r y p a n e l .
2 - 1 5 . E X T E R NA L C ON NE C T I ON S .
2 - 2 8
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
67/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 5 . ( c o n t )
a . S h e l t e r g r o u n d i n g
N O T E
S h e l t e r i s g r o u n d e d t h r o u g h e x t e r n a l l y c o n n e c t e d p o we r s u p p l y . A d d i t i o n a lg r o un d i n g , d e p en d i n g o n l o c a l c o n d i t i o ns , ma y b e i n s t a l l e d b y u t i l i z i n go p t i o n a l g r o u n d i n g r o d , A p p e n d i x D. Co n s u l t a q u a l i f i e d e l e c t r i c i a n f o rp r o p e r g r o u n d i n g p r o c e d u r e s r e q u i r e d f o r s u r r o u n d i n g s o i l c o n d i t i o n s .
( 1 ) D r i v e g r o u n d r o d i n t o e a r t h a t a s u i t a b l e l o c a t i o n t h a t p e r m i t s g r o u n d c a b l e a t t a c h e d t or o d t o r e a c h g r o u n d s t u d o n p o we r e n t r y p a n e l .
( 2 ) On p o we r e n t r y p a n e l r e mo v e n u t , s t a r w a s h e r , a n d f l a t wa s h e r o n s t u d .
( 3 ) C o n n e c t g r o u n d c a b l e c o n n e c t o r t o s t u d a n d s e c u r e wi t h wa s h e r , s t a r w a s h e r , a n d n u t .
( 4 ) Ch e c k a l l c o n n e c t i o n s f o r s e c u r i t y ,
b . I n p u t p o we r c o n ne c t i o n
W A R N I N G
( 1 )
( 2 )
Do n o t a t t e mp t c o n n e c t i o n o f l i v e l i n e t o p o we rp o w e r s o u r c e o r g e n e r a t o r b e f o r e p r o c e d u r e .
P o we r s u p p l y s h a l l b eCi r c u i t B r e a k e r P a n e l
C A U T I O N
e n t r y p a n e l . De a c t i v a t e
1 2 0 / 2 0 8 V a t , 4 wi r e wi t h 1 g r o u n d f o r Mo d e l NQOBo r 1 2 0 / 2 0 8 Va c , 4 wi r e wi t h 4 g r o u n d s f o r Mo d e l
NQOD Ci r c u i t B r e a k e r P a n e l o r d a ma g e t o e q u i p me n t w i l l r e s u l t .
T u r n a l l c i r c u i t b r e a k e r s t o OF F p o s i t i o n ,
N O T E
Ma k e c e r t a i n t h a t p o we r e n t r y p a n e l a n d p o we r s u p p l y c a b l e a r e t e r mi n a t e dwi t h s a me t y p e o f c o n n e c t o r .
Co n n e c t p o we r s u p p l y c a b l e t o p o we r e n t r y p a n e l a t c o n n e c t o r ( J 1 ) .
C h a n g e 2 2 - 2 9
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
68/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 5 . ( c o n t )
( 3 ) T u r n MAI N c i r c u i t b r e a k e r t o ON p o s i t i o n a n d o b s e r v e a n y u n u s u a lc o n d i t i o ns .
( 4 ) T u r n r e ma i n i n g c i r c u i t b r e a k e r s t o ON p o s i t i o n o n e a t a t i me a n do b s e r v e an y - u n u s u a l c o n d i t i o n s .
c . ECU Co n n e c t i o n .
( 1 ) T u r n CB1 t o OF F p o s i t i o n .
( 2 ) Co n n e c t ECU s u p p l y c a b l e t o
( 3 ) T u r n CB1 t o ON p o s i t i o n a n d
2 - 1 6 . CLOSI NG SEQUENCE
N O T E
F o u r p e r s o n n e l a r e r e q u i r e df o l l o wi n g p r o c e d u r e s .
c o n n e c t o r ( J 2 ) .
o b s e r v e f o r a n y u n u s u a l c o n d i t i o n s .
t o p e r f o r m t h e
Ma k e s u r e h i n g e d f l o o r i s c l e a r o f i t e ms o r d e b r i sa n d f l o o r h i n g e s a r e c l e a n o f s a n d o r d i r t .
Ma k e s u r e t o p o f h i n g e d r o o f i s c l e a r o f i t e ms ,d e b r i s , s n o w, o r i c e a n d h i n g e d f l o o r e x t e n s i o n i sc l e a r o f f o r e i g n ma t t e r , s n o w o r i c e .
Do n o t a t t e mp t t o l o we r o r r e mo v e c o n t a i n e r l i f t j a c k s u n t i l a f t e r p r o c e d u r e s i n s t e p s a t h r o u g h qh a v e b e e n c o mp l e t e d .
a . Re mo v e p o we r c o r d f r o m p o we r e n t r y p a n e l .
b . Re mo v e E CU i n t a k e a n d r e t u r n p a n e l s a n d r e p l a c e wi t h c l o s e o u t p a n e l s .
c . Re mo v e h i n g e d r o o f a r e a c e i l i n g l i g h t s a n d r e c e p t a c l e s f r o m e x p a n d e ds e c t i o n a n d r e t u r n t o t h e i r s t o wa g e p os i t i o n .
d . Re mo v e a n d s t o w l a t c h p l a t e s i n e q u i p me n t c o n t a i n e r .
2 - 3 0 CHANGE 2
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
69/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 6 . ( c o n t )
WAR N I N G
I t i s e s s e n t i a l t h a t t h e c o mp l e t e l a t c h i sp r e s s e d f l a t i n t o t h e p an .
e . Re l e a s e a l l l a t c h e s b e t we e n h i n g e d s i d e wa l l , e n d wa l l , r o o f , a n df l o o r .
f . L o we r s u p p o r t s t r u t s a n d r a i s e h i n g e d r o o f t o f u l l e x t e n t o f s t r u t .
8 . Di s e n g a g e q u i c k r e l e a s e p i n a n d s t o p p l a t e f o r c a b l e o n l o a db a l a n c e r .
h . L o we r h i n g e d f l o o r w i t h l e v e l i n g j a c k s .
i . F o l d i n h i n g e d e n d wa l l t o r o o f b e a m a n d h o l d i n p l a c e wi t h v e l c r os t r a p s .
j . L o we r h i n g e d r o o f b y u s i n g s u p p o r t s t r u t s a n d p e r s o n n e l a t e a c h e n do f r o o f .
k . S l i d e h i n g e d r o o f i n wa r d t o s t o wa g e p o s i t i o n b y p u l l i n g d o wn o ns o l a r b a r h an d l e s .
l . Re mo v e l e v e l i n g j a c k s s u p p o r t i n g h i n g e d f l o o r a n d s t o w o n l e f t c a r g od o o r .
m. Re mo v e s i d e wa l l s u p p o r t b r a c e s a n d s t o r e i n e q u i p me n t c o n t a i n e r .
WA R N I N G
T o a v o i d i n j u r y , b e c a r e f u l n o t t o g e t c a u g h t b e t we e nc a b l e a n d s i d e wa l l p a n e l . Do n o t a t t e mp t t o c o n t r o lp a n e l i f I t i s a c c i d e n t a l l y d r o p p e d .
n . F o l d d o wn h i n g e d s i d e wa l l o n t o h i n g e d f l o o r . A l l o w wa l l t o f r e ef a l l b e f o r e i t c o me s t o t h e s a me p l a n e a s t h e c a b l e s . T r a p p e d a i r a c t s a s ac u s h i o n .
o . P o s i t i o n c a ml o c k s s o h a n d l e s a r e v e r t i c a l a n d o u t wa r d .
f i r s t .Ra i s e h i n g e d f l o o r a n d c a ml o c k t o c o r n e r p o s t . E n g a g e l o we r l o c k s
Ma k e s u r e p i n s a r e i n h o l e s ,
C h a n g e 6 2 - 3 1
-
8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED
70/349
T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1
2 - 1 6 . ( c o n t )
NOTE
I f h i n g ed f l o o r a n d c o r n e r p o s t b i n d , r e l e v e l s h e l t e r .
q . Cl o s e c a r g o d o o r s .