TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

download TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

of 350

Transcript of TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    1/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    2/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    3/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    W A R N I N G

    HIGH VOLTAGE

    exists in the electrical system of this equipment

    DEATH ON CONTACT

    may result if personnel fail to observe safety precautions

    Before performing continuity checks or replacing electrical components,

    make sure that electrical power is completely disconnected from the circuitinvolved.

    In the event of fluorescent lamp breakage, care must be taken in the

    removal of broken glass fragments and white phosphorous dust. Inhalation of

    phosphorous dust could cause dangerous injury.

    Do not use handling equipment with capacity of less than gross weight of

    shelter system. Do not allow shelter to swing back and forth when it issuspended. Failure to observe this warning may result in damage to equipmentor severe injury or death to personnel.

    Methylethylketone (MEK) is flammable and toxic and must be used only in

    a well-ventilated area away from all sparks or open flame. Gloves should be

    worn during use.

    Lock stop plate on load balancer with quick release pin before disconnectingsupport cable from hinged floor.

    In extreme cold, do not touch metal parts with bare hands. Severe skin

    damage may result.

    Safety glasses must be worn by personnel when installing ground anchors.

    Expandable section (hinged floor and hinged sidewall together) weighs 700

    pounds (318 kg). Do not stand directly in front of hinged section.

    .Support cables attached to hinged floor must be locked out prior to

    removal/installation of hinged sidewall.

    Prior to removing load balancer from fixed roof, the hinged floor must be

    near stowed position to remove tension from support cable. The support cablebracket on hinged floor must then be removed to permit disconnecting support

    cable from hinged floor. Secure hinged floor to prevent accidental release.

    Do not attempt to disassemble or repair load balancer. This equipment

    contains powerful torsion springs and serious injury or death CO personnelcould result if disassembled.

    a/(b blank)

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    4/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    5/349

    TM 10-5411-200-14T.O. 35E4-177-1

    CHANGENO. 9 HEADQUARTERS, DEPARTMENT OF THE ARMY

    AND THE AIR FORCEWASHINGTON, DC, 31 AUGUST 2005

    TECHNICAL MANUAL

    OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERALSUPPORT MAINTENANCE

    FORSHELTER, TACTICAL, EXPANDABLE, TWO-SIDED

    NSN: 5411-01-136-9838

    NSN: 5411-01-294-9866

    DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.

    TM 10-5411-200-14, 1 April 1986, is updated as follows:

    1. File this sheet in front of the manual for reference.

    2. This change implements Army Maintenance Transformation and changes theMaintenance Allocation Chart (MAC) to support Field and SustainmentMaintenance.

    3. New or updated change information is indicated by a vertical bar in the outermargin of the page.

    4. Remove old pages and insert new pages as indicated below:

    Remove Pages Insert PagesA/(B Blank)

    B-1 through B-11/(B-12 Blank) B-1 through B-12

    Electronic 2028 Instructions Electronic 2028 Instructions/ Blank

    DA Form 2028 2028 Sample Front/Back

    2028 Front/2028 Back

    2028 Front/2028 Back

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    6/349

    ARMY TM 10-5411-200-14

    C-9

    By Order of the Secretary of the Army:

    PETER J. SCHOOMAKER

    General, United States Army

    Chief of Staff

    Official:

    SANDRA R. RILEY

    Administrative Assistant to the

    Secretary of the Army0521009

    MICHAEL E. RYAN

    GENERAL, USAF

    Chief of Staff

    Official:GEORGE T. BABBETT

    General, USAFCommander, Air Force Materiel Command

    Distribution: To be distributed in accordance with initial distribution number (IDN) 252533 requirements forTM 10-5411-200-14.

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    7/349

    CHANGE

    NO. 8

    ARMY TM 10-5411-200-14AIR FORCE T.O. 35E4-177-1

    C8

    HEADQUARTERS DEPARTMENTS OFTHE ARMY AND THE AIR FORCE

    WASHINGTON, D.C., 20 JANUARY 1997

    Operator, Organizational, Direct Support, and General Support

    Maintenance Manual

    SHELTER, TACTICAL, EXPANDABLE, TWO-SIDEDNSN 5411-01-136-9838 (60 AMP MODEL)NSN 5411-01-294-9866 (100 AMP MODEL)

    DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited

    TM 10-5411-200-14/ T.O. 35E4-177-1,1 April 1986, is changed as follows:

    1. The Cover is changed to add the 100 Amp Model.

    2. Remove and insert pages as indicated below. New or changed text material is indicated by avertical barin the margin. An illustration change is indicated by a miniature pointing hand.

    Remove pages

    2-1 and 2-2

    2-3 and 2-4

    2-17 and 2-18

    2- 8.1/ (2-18.2 blank)

    4-23 through 4-26

    4-39 through 4-46

    4-179 and 4-160

    4-181 and 4-182

    4-185 and 4-186

    C-5/ (C-6 blank)

    E-31 (E-4 blank)

    Cover

    Insert pages

    2-1 and 2-2

    2-3 and 2-4

    2-17 and 2-18

    2-18.1 through 2-18.3 (2-18.4 blank)

    4-23 through 4-26

    4-39 through 4-46

    4-179 and 4-180

    4-180.1 and 4-180.2

    4-181 and 4-182

    4-182.1 (4-182.2 blank)

    4-185 and 4-186

    4-186.1/ (4-186.2 blank)

    C-5/ (C-6 blank)

    E-3/ (E-4 blank)

    Cover

    3. Retain this sheet in front of manual for reference purposes.

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    8/349

    ARMY TM 10-5411-200-14AIR FORCE T.O.35E4-177-1

    C8

    By Order the Secretaries of the Army and Air Force:

    General, United States ArmyChief of Staff

    Administrative Assistant to theSecretary of the Army

    03151

    RONALD R. FOGELMAN

    General, USAF

    Chief of Staff

    HENRY VICCELLIO, JR.General, USAF

    Commander, Air Force Materiel Command

    DISTRIBUTION:To be distributed in accordance with DA Form 12-25-E, block no. 2533, requirements for

    TM 10-5411-200-14.

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    9/349

    C H A N GE

    NO. 7

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    C 7

    H E A D QU A R T E R SDEPARTMENTS OF THE ARMY AND THE AI R FORCE

    WA SHI NGT ON, D. C. , 1 5 De c e mb e r 1 9 9 4

    Op e r a t o r , Or g a n i z a t i o n a l , Di r e c t S u p p o r t , a n d Ge n e r a l Su p p o r t

    Ma i n t e n a n c e Ma n u a lF o r

    S HE L T E R, T A CT I CA L E XP ANDA BL E , T WO- S I DE D

    ( NS N 5 4 1 1 - 0 1 - 1 3 6 - 9 8 3 8 ) ( 6 0 A mp Mo d e l )

    ( NS N 5 4 1 1 - 0 1 - 2 9 4 9 8 6 6 ) ( 1 0 0 Amp Mo d e l )

    DI S T RI BUT I ON ST AT EME NT A: A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d .

    T M 1 O- 5 4 1 1 - 2 OO- 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d a s f o l l o ws :

    1 . R emo v e a n d i n s e r t p a ge s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i s i n d i c a t e d b y a v e r t i c ai n t h e ma r g i n . A n i l l u s t r a t i o n c h a ng e i s i n d i c a t e d b y a mi n i a t u r e p o i n t i n g h an d .

    R e m o v e p a g e s I n s e r t p a g e s

    1 - 1 a n d 1 - 2 1 - 1 a nd 1 - 2

    D- 1 / ( D- 2 b l a nk ) D- 1 a n d D- 2

    2 . R e t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    10/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E 4 - 1 7 7 - 1

    C 7

    By Or d e r o f t h e S e c r e t a r l e s o f t h e Ar my a n d Ai r F o r c e :

    O f f i c i a l :

    MI L T O N H. HA MI L T O NA d m i n i s t t a t i v e A s s i s t a n t t o t h e

    S e c r e t a r y o f t h e A r my 0 7 6 6

    GOR DON R. S UL L I V A NGe n e r a l , Un i t e d St a t e s A r my

    C h i e f o f S t a f f

    ME RRI L L A . Mc P E A KGe n e r a l , USAFCh i e f o f S f a f f

    R ON A L D W. Y A T E S

    Ge n e r a l , US A F Co mma n d e r A i r F o r c e Ma t e r i e l Co mma n d

    DI S TRI B UT I ON:

    T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA Fo r m 1 2 - 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o rT M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    11/349

    CHANGE

    NO. 6

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    C 6

    HEADQUARTERSDEPARTMENTS OF T HE ARMY AND A I R FORCE

    WASHI NGT ON, D. C. , 2 8 F e b r u a r y 1 9 9

    Op e r a t o r , Or g a n i z a t i o n a l , Di r e c t Su p p o r t , a n d Ge n e r a l

    Ma i n t e n a n c e Ma n u a l

    S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D( NSN 5 4 1 1 - 0 1 - 1 . 3 6 - 9 8 3 8 ) ( 6 0 Amp Mo d e l )( NSN 5 4 1 1 - 0 1 - 2 9 4 - 9 8 6 6 ) ( 1 0 0 Amp Mo d e l )

    DI S T RI B UT I ON S T AT E ME NT A : A p p r o v ed f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d .

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d a s f o l l o ws :

    1 . Re mo v e an d i n s e r t p a ge s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i si n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n . An i l l u s t r a t i o n c h a n g e i s i n d i c a t eb y a mi n i a t u r e p o i n t i n g h a n d .

    R e m o v e p a g e s I n s e r t p a g e s

    i a n d i i i a n d i i2 - 3 1 a n d 2 - 3 2 2 - 3 1 a n d 2 - 3 2C- 3 a n d C- 4 C- 3 a n d C- 4

    2 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    12/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O . 3 5 E 4 - 1 7 7 - 1

    C- 6

    B y Or d e r o f t h e Se c r e t a r i e s o f t h e Ar my a n d A i r F o r c e :

    Of f i c i a l :

    GOR DON R. S UL L I V A NGe n e r a l , Un i t e d St a t e s A r my

    Ch i e f o f S t a f f

    MI L T O N H . H AMI L T O NA d m i n i s t r a t i v e A s s i s t a n t t o t h e

    S e c r e t a r y o f t h e A r m y 0 6 2 5 6

    ME RR I L L A . Mc P E AKGe n e r a l , US AF Ch i e f o f S t a f f

    O f f i c i a l :

    R ON A L D W. Y A T E SGe n e r a l , US AF Co mma n d e r A i r F o r c e Ma t e r i e l Co mma n d

    DI S T RI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F o r m 1 2 - 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o r

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    13/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    14/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E 4 - 1 7 7 - 1

    B y Or d e r o f t h e Se c r e t a r i e s o f t h e Ar my a n d Ai r F o r c e :

    O f f i c i a l :

    GOR DON R. S UL L I V A N

    Ge n e r a l , Un i t e d St a t e s A r my C h i e f o f S t a f f

    MI L T O N H. HA MI L T O NA d mi n i s t r a t i v e A s s i s t a n t t o t h e

    S e c r e t a r y o f t h e Ar my 0 4 9 9 0

    ME RR I L L A . Mc P E AKGe n e r a l , US AF Ch i e f o f S t a f f

    o f f i c i a l :

    R ON A L D W. Y A T E SGe n e r a l , US AF C o mma n d e r A i r F o r c e Ma t e r i e l C o mma n d

    DI S TRI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F or m 1 2 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o r

    T M 1 0 5 4 1 1 2 0 0 - 1 4 .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    15/349

    A RMY T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4A I R F ORCE T. O. 3 5 E 4 - 1 7 7 - 1

    C 4

    CHANGE HEADQUARTERS,

    DEPARTMENTS OF THE ARMY AND AI R FORCENO. 4 WA SHI NGT ON, D. C. 3 0 A p r i l 1 9 9 3

    Op e r a t o r , Or g a n i z a t i o n a l , D i r e c t S u p p o r t , a n d Ge n e r a l S u p p o r tMa i n t e n a n c e Ma n u a l

    S HE L T E R, T A CT I C AL , E X PA ND AB L E , T WO- S I D ED

    D I S T R I B UT I ON S T A T E ME NT

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O.

    NS N 5 4 1 1 - 0 1 - 1 3 6 - 9 8 3 8 ( 6 0 A MP MODE L )N SN 5 4 1 1 - 0 1 - 2 9 4 - 9 8 6 6 ( 1 OO A MP MODE L )

    A : A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d .

    3 5 E 4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 i s c h a n g e d a s f o l l o ws :

    1 . Re mo v e an d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i si n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n . A n i l l u s t r a t i o n c h a n g e i s i n d i c a t e db y a mi n i a t u r e p o i n t i n g h a n d .

    R e m o v e p a g e s I n s e r t p a g es

    4 - 1 7 1 a n d 4 - 1 7 2 4 - 1 7 1 a n d 4 - 1 7 2D- 1 / ( D- 2 b l a n k ) D- 1 / ( D- 2 b l a nk )E- 1 t h r o u g h E - 3 / ( E- 4 b l a n k ) E- 1 t h r o u g h E- 3 / ( E- 4 b l a n k )

    2 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    16/349

    A RMY T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4A I R F ORCE T . O. 3 5 E 4 - 1 7 7 - 1

    B y Or d e r o f t h e Se c r e t a r i e s o f t h e Ar my a n d A i r F o r c e :

    Of f i c i a l :

    GOR DON R. S UL L I V A N

    Ge n e r a l , Un i t e d St a t e s A r my C h i e f o f S t a f f

    MI L T O N H . H AMI L T O N

    A d m i n i s t r a t i v e A s s i s t a n t t o t h e S e c r e t a r y o f t h e A r m y

    0 4 0 7 8

    ME RRI L L A . Mc P EA K

    Ge n e r a l , US A F Ch i e f o f S t a f f

    Of f i c i a l :

    R ON A L D W. Y A T E S

    Ge n e r a l , US A F C o mma n d e r , A i r F o r c e Ma t e r i e l C o mma n d

    DI S TRI B UT I ON:

    T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F o r m 1 2 - 2 5 - E , b l o c k n o . 2 5 3 3 , r e q u i r e me n t s f o rT M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 . .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    17/349

    C H A N G E

    NO. 3

    A RMY T M 1 0 - 5 4 1 1 - 2 0 0 - 1A I R F ORCE T . O. 3 5 E 4 - 1 7 7 -

    C 3

    H E A D Q u A R T E R S ,DEPARTMENTS OF T HE ARMY AND A I R FORCE

    WA SHI NGT ON, D. C. , 2 3 Ma y 1 9 9 1

    Op e r a t o r , Or g a n i z a t i o n a l , Di r e c t S u p p o r t a n d Ge n e r a l S u p p o r tMa i n t e n a n c e Ma n u a l

    S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D

    NS N 5 4 1 1 - 0 1 - 1 3 6 9 8 3 8 ( 6 0 A MP MODE L )

    NS N 5 4 1 1 4 1 - 2 9 4 - 9 8 6 6 ( 1 0 0 A MP MODE L )

    A p p r o v e d f o r p u b l i c r e l e a s e ; d i s t r i b u t i o n i s u n l i mi t e d

    T M 1 0 - 5 4 1 1 2 0 0 - 1 4 / T . O . 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 i s c h a n g e d a s f o l l o ws :

    1 . R emo v e a n d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a l i s i n d i c a t e d b y a v e r t i c a l

    t h e ma r g i n . A n i l l u s t r a t i o n c h a n g e i s i n d i c a t e d b y a mi n i a t u r e p o i n t i n g h a n d .

    R e m o v e p a g e s I n s e r t p a g e s

    1 - 1 a n d 1 2 1 - 1 a n d 1 2

    1 - 5 a n d 1 - 6 1 - 5 a n d 1 - 6

    C 3 a n d C - 4 C 3 a n d C - 4

    2 . R e t a i n t h i s s h e e t i n f r o n t o f m a n u a l f o r r e f e r e n c e p u r p o s e s .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    18/349

    By Or d e r o f t h e Se c r e t a r i e s o f t h e Amy a n d A i r F o r c e :

    C A RL E . V U ON O

    Ge n e r a l , Un i t e d S t a t e s Ar my

    Ch i e f o f S t a f f

    O f f i c i a l :P AT RI CI A P. HI CK ERS ON

    Co l o n e l , Un i t e d St a t e s Ar my T h e A d j u t a n t Ge n e r a l

    ME RRI L L A . Mc P EA K

    Ge n e r a l U S A F C h i e f o f S t a f f

    O f f i c i a l :

    C HA RL E S C . Mc D ON A L D

    Ge n e r a l , US A F

    Co mma n d e r , A i r F o r c e L o g i s t i c s C o mma n d

    DI S TRI B UT I ON:

    T o b e d i s t r i b u t e d i n a c c o r d a nc e wi t h DA F or m 1 2 - 2 5 E , ( q t y r q r b l o c k no . 2 5 3 3 ) .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    19/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    CHANGE

    No . 2

    H E A D QU A R TE R S , D E P A R TME N TS OFTH E A R MY A N D TH E A I R FO RC E

    WA SHI NGT ON, D. C. , 1 4 F e b r u a r y 1 9 9 0

    Op er a t o r , Or g a n i z a t i o na l , Di r e c t Su p p o r t ,An d Ge n e r a l Su p p o r t Ma i n t e n a n c e

    S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D( NSN 5 4 1 1 - 0 1 - 1 3 6 - 9 8 3 8 ) ( 6 0 A mp Mo d e l )

    ( NSN 5 4 1 1 - 0 1 - 2 9 4 - 9 8 6 6 ) ( 1 0 0 Amp Mo d e l )

    Ap pr o v e d f o r p u b l i c r e l e a s e ; Di s t r i b u t i o n i s u n l i mi t e d .

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d as f o l l o ws :

    1 . T i t l e i s c h a n g e d a s s h o wn a b o v e .

    2 . Re mo v e a n d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a li s i n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n . An i l l u s t r a t i o n c h a n g e i s i n d i c a t e db y a mi n i a t u r e p o i n t i n g h a n d .

    R e m o v e p a g e s I n s e r t p a g e s

    i a n d i i1 - 1 t h r o u g h 1 - 62 - 1 a n d 2 - 22 - 9 t h r o u g h 2 - 1 42 - 1 7 a n d 2 - 1 8- - -

    2 - 2 1 t h r o u g h 2 - 2 4- - - -

    2 - 2 9 a n d 2 - 3 03 - 7 a n d 3 - 8

    4 - . 5 t h r o u g h 4 - 1 2- - -

    4 - 1 3 a n d 4 - 1 44 - 2 7 t h r o u g h 4 - 3 64 - 4 7 t h r o u g h 4 - 5 4- - -

    4 - 5 5 a n d 4 - 5 64 - 1 7 9 t h r o u g h 4 - 1 8 6- - -

    5 - 5 t h r o u gh 5 - 8A - 1 / A - 2D- 1 / D- 2E- 1 a n d E - 2

    - - -I n d e x 1 t h r o u g h I n d e x 4

    i a n d i i1 - 1 t h r o u g h 1 - 62 - 1 a n d 2 - 22 - 9 t h r o u g h 2 - 1 42 - 1 7 a n d 2 - 1 82 - 1 8 . 1 / 2 - 1 8 . 22 - 2 1 t h r o u g h 2 - 2 42 - 2 4 . 1 / 2 - 2 4 . 22 - 2 9 a n d 2 - 3 03 - 7 a n d 3 - 84 - 5 t h r o u g h 4 - 1 24 - 1 2 . 1 a n d 4 - 1 2 . 24 - 1 3 a n d 4 - 1 44 - 2 7 t h r o u g h 4 - 3 64 - 4 7 t h r o u g h 4 - 5 44 - 5 4 . 1 a n d 4 - 5 4 . 24 - 5 5 an d 4 - 5 64 - 1 7 9 t h r o u g h 4 - 1 8 64 - 1 8 7 t h r o u g h 4 - 1 9 05 - 5 t h r o u g h 5 - 8A - 1 / A - 2D- 1 / D- 2E- 1 a n d E - 2

    E - 3 / E - 4I n d e x 1 t h r o u g h I n d e x 4

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    20/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    C 2

    3 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e pu r p o s e s .

    By Or d e r o f t h e Se c r e t a r i e s o f t h e A r my a n d t h e A i r F o r c e :

    C A RL E . V U ON 06 e n e r a l , Un i t e d S t a t e s Amy

    Ch i e f o f S t a f f

    Of f i c i a l :WI L L I AM J . ME EHA N, I I

    B r i g a d i e r 6 e n e r a l , Un i t e d S t a t e s Ar myT h e Ad j u t a n t 6 e n e r a l

    L A RRY D. WE L CH, 6 e n e r a l US AFCh i e f o f S t a f f

    Of f i c i a l :A L F R E D G. H AN SE N

    Ge n e r a l , USAF , Co mma n d e r , A i r F o r c eL o g i s t i c s C omma n d

    DI S TRI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA 1 2 - 2 5 A , Op e r a t o r , Un i t , Di r e c t Su p p o r t

    a n d Ge n e r a l Su p p o r t Ma i n t e n a n c e r e q u i r e me n t s f o r S h e l t e r , Ex p a n d a b l e , 2 - S i d e( 5 - 4 - 3 1 1 8 - 2 ) .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    21/349

    CHANGE

    No . 1

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 W4 - 1 7 7 - 1

    C 1

    HEADQUARTERSDEPARTMENTS OF T HE ARMY AND AI R FORCE

    WAS HI NGT ON, D. C. , 8 J u n e 1 9 8 9

    Op er a t o r , Or g a n i z a t i o n a l , Di r e c t Su p p o r t

    a n d Ge n e r a l Su p p o r t Ma i n t e n a n c e

    S HE L T E R, T A CT I CA L , E XP ANDA BL E , T WO- S I DE D( NSN 5 41 1 - 0 1 - 1 3 6 - 9 8 3 8 )

    Ap p r o v e d f o r p u b l i c r e l e a s e . Di s t r i b u t i o n i s u n l i mi t e d .

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4 / T . O. 3 5 E4 - 1 7 7 - 1 , 1 Ap r i l 1 9 8 6 , i s c h a n g e d a s f o l l o ws :

    1 . Re mo v e a n d i n s e r t p a g e s a s i n d i c a t e d b e l o w. Ne w o r c h a n g e d t e x t ma t e r i a li s i n d i c a t e d b y a v e r t i c a l b a r i n t h e ma r g i n , An i l l u s t r a t i o n c h a n g e i s i n d i c a t e db y a mi n i a t u r e p o i n t i n g h a n d .

    R e m o v e p a g e s I n s e r t p a g e s

    2 - 2 9 a n d 2 - 3 0 2 - 2 9 a n d 2 - 3 0D- 1 / D- 2 D- 1 / D- 2

    2 . Re t a i n t h i s s h e e t i n f r o n t o f ma n u a l f o r r e f e r e n c e p u r p o s e s .

    By Or d e r o f t h e Se c r e t a r i e s o f t h e A r my a n d t h e A i r F o r c e :

    C A RL E . V U ON O

    Ge n e r a l Un i t e d St a t e s A r my

    O f f i c i a l :

    WI L L I AM J . MEE HA N, I IB r i g a d i e r Ge n e r a l , Un i t e d St a t e s A r my

    T h e A d j u t a n t Ge n e r a l

    O f f i c i a l :

    A LF R E D G. H A NS E N

    Ge n e r a l , US A F , Co mma n d e r , A i r F o r c e L o g i s t i c s Co mma n d

    Ch i e f o f S t a f f

    L A R R Y D . WE L C H , Ge n e n a l US A F Ch i e f o f S t a f f

    DI S TRI B UT I ON:T o b e d i s t r i b u t e d i n a c c o r d a n c e wi t h DA F o r m 1 2 - 2 5 A , Op e r a t o r , Un i t , Di r e c t

    Su p p o r t a n d Ge n e r a l S u p p o r t Ma i n t e n a n c e r e q u i r e me n t s f o r S h e l t e r , Ex p a n d a b l e ,Ri g i d Co n s t r u c t i o n , W/ A i r L o c k Mo d e l SEU- 2 ( T M 1 0 - 5 4 1 0 - 2 2 1 Se r i e s ) a n d f o rSh e l t e r , E x p a n d a b l e , S h o p , A i r c r a f t Ma i n t e n a n c e , Po r t a b l e ( T M 1 0 - 5 4 1 0 - 2 2 4 Se r i e s ) .

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    22/349

    TM 10-5411-200-14T.O. 35E4-177-1

    INSERT LATEST CHANGED PAGES. DESTROY SUPERSEDED PAGES.

    A/(B Blank) Change 9USA

    LIST OF EFFECTIVE PAGES

    NOTE: The portion of text affected by the update is indicated by a vertical line in the outer margins of the

    page. Updates to illustrations are indicated by shaded or screened areas, or by miniaturepointing hands. Zero in the Change No. column indicates an original page or work package.

    Dates of issue for original and changed pages / work packages are:

    Original .. 0 .. 1 April 1986 Change .. 5 .. 30 July 1993

    Change .. 1 .. 8 June 1989 Change .. 6 .. 28 February 1994

    Change .. 2 .. 14 February 1990 Change .. 7 .. 15 December 1994

    Change .. 3 .. 23 May 1991 Change .. 8 .. 20 January 1997

    Change .. 4 .. 30 April 1993 Change .. 9 .. 31 August 2005

    TOTAL NUMBER OF PAGES FOR THIS PUBLICATION IS 350, CONSISTING OF THE FOLLOWING:

    PageNo.

    ChangeNo.

    PageNo.

    ChangeNo.

    PageNo.

    ChangeNo.

    PageNo.

    ChangNo.

    Cover 0 2-15 through 2-17 0 4-26 8 5-5 2

    a/(b Blank) 02-18 through2-18.3/(2-18.4 Blank)

    8 4-27 0 5-6 0

    i 6 2-19 through 2-21 0 4-28 through 4-36 2 5-7 2

    ii 2 2-22 2 4-37 through 4-39 0 5-8 through 5-14 0

    1-0 0 2-23 0 4-40 through 4-45 8 6-1 through 6-4 0

    1-1 22-24 through2-24.1/(2-24.2 Blank)

    2 4-46 0 A-1/(A-2 blank) 2

    1-2 7 2-25 through 2-28 0 4-47 through 4-55 2 B-1 through B-12 9

    1-3 2 2-29 through 2-30 2 4-56 through 4-92 0 C-1 through C-3 0

    1-4 0 2-31 6 4-93 through 4-95 5 C-4 6

    1-5 3 2-32 through 2-36 0 4-96 through 4-99 0 C-5/(C-6 blank) 8

    1-6 2 3-1 through 3-7 0 4-100 through 4-108 5 D-1 through D-2 7

    2-1 8 3-8 2 4-109 through 4-179 0 E-1 0

    2-2 23-9 through3-15/(3-16 Blank)

    04-180 through4-182.1/(4-182.2 Blank)

    8 E-2 4

    2-3 8 4-1 through 4-4 0 4-183 2 E-3/(E-4 blank) 8

    2-4 through 2-8 0 4-5 through 4-13 2 4-184 through 4-185 0 Index-1 2

    2-9 through 2-12 2 4-14 through 4-22 04-186 through4-186.1/(4-186.2 Blank)

    8 Index-2 0

    2-13 0 4-23 through 4-24 8 4-187 through 4-190 2Index-3 throughIndex-4

    2

    2-14 2 4-25 0 5-1 through 5-4 0 Back Cover 0

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    23/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    24/349

    TM 10-5411-200-1T.O. 35E4-177-

    TECHNICAL MANUAL HEADQUARTERS, DEPARTMENTS

    THE ARMY AND THE AIR FORNO. 10-5411-200-14 WASHINGTON, D.C., 1 April 19

    OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT,

    AND GENERAL SUPPORT MAINTENANCE

    SHELTER, TACTICAL, EXPANDABLE, TWO-SIDED

    (NSN 5411-01-136-9838)(60 Amp Model)

    (NSN 5411-01-294-9866)(100 Amp Model)

    DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimite

    L

    REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS

    You can help improve this manual. If you find any mistakes or if you know of

    a way to improve the procedures, please let us know. Reports shall be sub-mitted as follows: A reply will be furnished to you.

    (A) Army - DA Form 2028 (Recommended Changes to Publications and BlankForms), or DA Form 2028-2 located in the back of this manual direct to:

    Commander, U.S. Army Aviation and Troop Command, ATTN: AMSAT-I-MP, 430

    Goodfellow Boulevard, St. Louis, MO 63120-1798.

    (F) Air Force - AFTO Form 22 directly to: Commander, Sacramento AirLogistics Center, ATTN: MMST, McClellan Air Force Base, CA 95652 inaccordance with TO-00-5-1,

    CHAPTER 1

    Section I.

    Section II.

    1-1

    1-1

    1-3

    CHAPTER 2

    Section I.

    Section II.

    Section III.

    Section IV.

    Section V.

    CHAPTER 3Section I.

    Section II.

    TABLE OF CONTENTS

    Page

    INTRODUCTIONGeneral Information

    Equipment Description and Data

    OPERATING INSTRUCTIONS

    Description and Use of Operators Controls and

    Indicators

    Operators Preventive Maintenance Checks and

    Services (PMCS)Service Upon Receipt of Shelter

    Operation Under Usual Conditions

    Operation Under Unusual Conditions

    OPERATOR MAINTENANCE INSTRUCTIONSTroubleshooting Procedures

    Operator Maintenance Procedures

    2-1

    2-1

    2-42-11

    2-32

    2-33

    3-1

    3-1

    3-4

    Change 6 i

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    25/349

    TM 10-5411-200-14T.O. 35E4-177-1

    TABLE OF CONTENTS (cont)

    CHAPTER 4 ORGANIZATIONAL MAINTENANCE INSTRUCTIONS

    Section I Repair Parts, ,Special Tools, TMDE, and Support

    Equipment

    Section II. Troubleshooting Procedures

    Section III. Organizational Maintenance Procedures

    Section IV. Preparation for Storage and Shipment

    CHAPTER 5 DIRECT SUPPORT MAINTENANCE INSTRUCTIONS

    CHAPTER 6 GENERAL SUPPORT MAINTENANCE INSTRUCTIONS

    APPENDIX A REFERENCES

    APPENDIX B MAINTENANCE ALLOCATION CHART

    APPENDIX C COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS

    LIST

    APPENDIX D ADDITIONAL AUTHORIZED LIST

    APPENDIX E EXPENDABLE SUPPLIES AND MATERIALS LIST

    ALPHABETICAL INDEX

    Page

    4-1

    4-1

    4-2

    4-5

    4-190

    5-1

    6-1

    A-1

    B-1

    C-1

    D-1

    E-1

    INDEX-1

    ii CHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    26/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    EXPANDED SHELTER

    Full External View of Two-Sided Expandable Tactical Shelter

    1-0

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    27/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    CHAPTER 1

    INTRODUCTION

    Section 1. GENERAL INFORMATION

    1-1. SCOPE. This manual is for use by personnel responsible for operation and maintenance of the

    two-sided expandable tactical shelter assembly, which will be referred to as the shelter. It provides the

    user with necessary instructions to use the shelter and to perform required maintenance in accordance

    with the Maintenance Allocation Chart in Appendix B.

    NOTE

    Some portions of this publication are not applicable to all services. These

    portions are prefixed to indicate the services to which they pertain (A)

    for Army, (F) for Air Force, and (N) for Navy. Portions not prefixed

    are applicable to all services.

    1-2. MAINTENANCE FORMS, RECORDS, AND REPORTS. Maintenance forms. records, and reports

    used by:

    a. (A) Are prescribed by DA PAM 736-750, the Army Maintenance Management System

    (TAMMS).

    b. (F) Are prescribed in AFM-66-1 and the applicable 00-20 Series Technical Orders.

    c. (N) Refer to their service peculiar directives to dtermine applicable maintenance forms and

    records to be used.

    d. (A) Users shall refer to the Maintenance Allocation Chart (MAC) for task and levels ofmaintenance to be performed. Where the density of equipment is not sufficient to authorize unit

    personnel with skills necessary to perform unit-level maintenance functions, AR 750-1, paragraph 2-8c

    states, Unserviceable reparable, (properly preserved, protected, and tagged) that are beyond the

    authorized capability or capacity to repair, will be evacuated through the appropriate SUPPLY support

    activities for repair or exchange. For units authorized personnel with skills to perform greater than

    unit-level maintenance functions, AR 750-1, paragaph 2-9b states, "DS and GS units may grant authority

    to supported units to perform the next higher level repair, if the supported unit has the capability and

    capacity to perform the repair.

    (F) Users shall accomplish maintenance at the user level consistent with their capability in

    accordance with policies established in AFM 66-1.

    f. (N) Users shall determine their maintenance levels in accordance with their service directives.

    1-3. (A) DESTRUCTION OF MATERIEL TO PREVENT ENEMY USE. For destruction procedures. for materiel refer to TM 750-244-3.

    14. ADMINISTRATIVE STORAGE. For procedures and inspections required during administrative

    storage, refer to Chapter 4, paragraph 4-44.

    Change 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    28/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    1-5. (A) REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATIONS (EIRS). If your shelterneeds improvement, let us know. Send us an EIR. You, the user, are the only one who can tell us what you

    dont like about your equipment. Let us know why you dont like the design. Tell us why a procedure is hard

    to perform. Put it on an SF 368 (Quality Deficiency Report). Mail it to: Commander, U. S. Army Aviation

    and Troop command ATTN: AMSAT-I-MDO, 4300 Goodfellow Boulevard, St. Louis, Missouri, 63120-1798.

    Well send you a reply.

    1-6. LIST OF ABBREVIATIONS.

    AC

    cm

    ECU

    EIR

    ft

    Hz

    in.

    IS0

    kg

    lb pound

    lg

    MAC

    MEK

    m m

    MTOE

    No.

    PMCS

    ref

    sq

    TMDE

    W C

    Air conditioner

    centimeter

    Environmental Control Unit

    Equipment Improvement Report

    foot (feet)

    Hertz

    inch

    International standards Organization

    Kilogram

    long

    Maintenance Allocation chart

    Methylethylketone (Solvent)

    millimeter

    Modified Table of Organization and Equipment

    number

    Preventive Maintenance Checks and Services

    reference

    square

    Test, Measurement and Diagnostic Equipment

    Volts, alternating current

    1-2 Change 7

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    29/349

    TM 10-5411-200-

    T.O. 35E4-177-

    Section II. EQUIPMENT DESCRIPTION AND DATA

    1-7. PURPOSE OF TWO-SIDED EXPANDABLE TACTICAL SHELTER ASSEMBLY. A self-contained transportable multi-application utility shelter. A member of family

    of standard rigid wall ISO shelters to be used by branches of the Department Defense.

    Capabilities and Features:

    q Equipped with standard ISO fittings for easy transportability.

    q Provided with mobilizer fittings for mobilizer transportation.

    q Built-in fork lift provisions.

    q All weather operation.

    q Environmentally controlled interior.

    q Rigid wall construction.

    q Simple and fast deployment.

    q Designed to operate under blackout conditions with door activated blackoswitch.

    q External electrical power connection.

    q Easy to maintain.

    Differences Between Models:

    q The early model Shelter, Tactical, Expandable, Two-Sided (NSN 5411-01-13

    9838), provides overload protection through a 60 amp or 100 amp Model NQ

    circuit breaker panel, manufactured by Square D Company. When replacemeof the circuit breaker panel is necessary, the replacement will be Model

    NQOD circuit breaker panel, which is also manufactured by Square D Compaand has the capability to accommodate either 60 amp or 100 amp service.

    Model NQOD is two inches shorter in length than the earlier Model NQOB,

    and modifications to the shelters are required when replacement is

    necessary (see paragraph 4-7.1).

    NOTE

    All electrical components (circuit breakers, switches, andwiring) used in the earlier model circuit breaker panel arecompatible with the new Model NQOD.

    q The late model Shelters, Tactical, Expandable, Two-Sided (NSN 5411-01-29

    9866) are initially equipped with the new Model NQOD circuit breaker pan

    when placed into service.

    cHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    30/349

    TM 10-5411-200-14T.O. 35E4-177-1

    1-8. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS.

    1-4

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    31/349

    TM 10-5411-200-14T.O. 35E4-177-1

    1-8. (cont)

    1.

    2.

    3.

    4.

    5.

    6.

    7.

    8.

    9.

    10.

    11.

    12.

    13.

    14.

    15.

    W A R N I N G

    LEFT AND RIGHT CARGO DOORS, Provides access to shelter for delivery of bulky materiel and equipment

    Door vents are spring loaded to swing upward. To prevent

    injury, hold door vent shut while unlatching all the retaining

    clips.

    DOOR VENTS. Manually operated vents provide ventilation and pressure equalization for the shelter.

    HINGED ENDWALLS. Hinged to center structure and swing out to form walls in the expandable section of

    shelter.

    HINGED SIDEWALL. Hinged to hinged floor panel. Forms a wall in the expandable section when shelter is

    expanded.

    LEVELING JACKS. Secured to hinged floor and hinged sidewall. Provides leveling means for the expandable

    section.

    HINGED FLOOR PANEL. Hinged to fixed floor panel. Provides additional floor space when shelter is expanded

    EXPANDABLE SIDE LOAD BALANCER. Consists of cable reels, cable guides, and support cable to assist i

    expanding and closing of hinged floor panel and hinged sidewall.

    ECU PANELS. Provides for connections of ECU equipment used with shelter

    Shelter grounding is not optional on shelters used for

    Deployable Medical Systems (DEPMEDS).

    POWER ENTRY PANEL. A service entrance connector on this panel receives external primary input power for

    shelter and routes it to a circuit breaker panel inside the shelter. Includes provisions for optional shelter groundin

    and telephone connections.

    FIXED PERSONNEL DOOR. Provides access to shelter. The only door used during blackout conditions.

    CONTAINER LIFT JACKS. Provides leveling means for fixed section of shelter by means of 150 fittings

    EQUIPMENT CONTAINER CHEST. Contains leveling jack extensions, storm configuration (shelter tie-down

    kit, area light incandescent bulb, removable latches, support braces, and screwdriver.

    AREA LIGHT. Attaches to either personnel or cargo endwall panels to provide illumination at either end of

    shelter. Plugs into receptacle on power entry panel.

    CIRCUIT BREAKER PANEL. Provides overload protection for shelter circuits. Main circuit breaker switche

    off all electrical power to shelter.

    HINGED ROOF PANEL. Hinged to center structure roof. Swings up to provide roof for expandable section o

    the shelter.

    W a r n i n g

    Change 3 1-5

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    32/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    1-8. (cont)

    16. FIXED PANELS. Consists of personnel and cargo end, fixed floor, and fixed.

    roof panels. Used for equipment storage during transportation. All hinged

    panels are hinged to fixed container.

    17. SUPPORT BRACES. Provides support to hinged sidewall during expandingprocedures only.

    18. CLOSEOUT PANELS. Used to cover openings in endwalls and sidewalls.

    1-9. EQUIPMENT DATA.

    Exterior Dimensions (Stowed Shelter)

    Width. . . . . . . . . . . . . . .

    Height. . . . . . . . . . . . . . . .

    Length. . .. .. . . . . . . .

    Exterior Dimensions (Expanded Shelter)Width. . . . . . . . . . . .

    Height. . . . .. . . . . . . . .

    Length. . . .. . . .. . .. . .

    Interior Dimensions

    Minimum clear height . . . . . . . .

    Minimum clear width (stowed mode) .Usable floor space . . . . . . . . .

    Total Weights

    Less payload . . . . . . . . . . . .

    With payload (maximum) . . . . . . .

    Primary Power Requirements

    NQOB Model . . . . . . . . . . . . .

    NQOD Model . . . . . . . . . . . . .

    Environmental Limits

    Operating temperature . . . . . . .

    Transportability (Stowed Shelter)

    ISO fittings . . . . . . . . . . . .

    Dolly Set . . . . . . . . . . . . .

    Fork Lift . . . . . . . . . . . . .

    8 ft. (2.44 meters)

    8 ft. (2.44 meters)

    l9 ft., 10-1/2 i. (6.05 meters)

    21 ft., 9 in. (6.63 meters)

    8 ft., (2.44 meters)

    19 ft., 10-1/2 in. (6.05 maters)

    80.29 in. (2.04 meters)

    77.78 in. (1.98 meters)

    400 sq. ft. (37.2 sq. meters)

    6,900 lbs. (3130 kg)

    15,000 lbs. (6804 kg)

    120/208 Vat, 60 Hz, 3 phase, 4 wire with

    1 grid.

    120/208 Vac, 60 Hz, 3 phase, 4 wire with4 grids.

    -65F to +125F (-53.9C to 51.7C)

    Provided with upper and lower IS0

    fittings in accordance with specifica-tion IS0 1496/1.

    Equipped with mobilizer fittings fortransportation with mobilizer. Model

    No. M832- 10,000 pounds (4546 Kg)

    maximum capacity (TM 9-2330-275-14&P).

    Model No. M1022 15,000 pounds (6804 Kg)

    maximum capacity (TN 9-2330-379-14&P).

    Built-in fork lift provisions.

    1-6 CHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    33/349

    TM 10-5411-200-1T.O. 35E4-177-

    CHAPTER 2

    OPERATING INSTRUCTIONS

    Section I. DESCRIPTION AND USE OF OPERATORS CONTROLS AND INDICATORS

    2-1. SCOPE. This section provides description and use of operator controls and indicators needed to operatshelter. This section provides descriptions for circuit breaker panel controls and indicators (See paragraph 2-and personnel end panel mounted controls and indicators (See paragraph 2-3).

    INSIDE VIEW - LOOKING AT PERSONNEL END PANEL

    CHANGE 8 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    34/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    35/349

    TM 10-5411-200-T.O. 35E4-177

    2-2. (cont)

    Control or Indicator Function

    6 Circuit breaker Provides overload protection for interior utility outletsmounted on sidewall.

    7 Circuit breaker Provides overload protection for ground fault inter-

    rupter utility outlet mounted on power entry panel.8 Circuit breaker Provides overload protection for interior utility outlets

    mounted on hinged sidewall and hinged endwalls.

    9 Circuit breaker Provides overload protection for interior utility outletmounted on hinaed sidewall and hinged endwalls.

    2-3. PERSONNEL END PANEL MOUNTED CONTROLS AND INDICATORS

    Control or Indicator Function

    1 Door activated blackout switch During blackout conditions it turns off all lights inshelter when fixed end personnel door is opened.To override operation of this switch, the circuit breaer panel mounted blackout override switch must bein ON position. Circuit protected against overload bcircuit breaker.

    2 Ceiling lights switch In ON position, turns on nine fluorescent lights inshelter. In OFF position turns off all fluorescentlights. Circuit protected against overload by circuitbreaker.

    CHANGE 8

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    36/349

    TM 10-5411-200-14T.O. 35E4-177-1

    Section II OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS.)

    2-4. GENERAL. For the shelter to be ready for use at al l t imes, i t must beinspected systematically so that defects may be discovered and correctedbefore they result in serious damage or fai lure.

    Before you operate. Always keep in mind the CAUTIONS and WARNINGS.

    Perform your "B-before" PMCS (Table 2-1).

    b. While you operate. Always keep in mind the CAUTIONS and WARNINGS.

    Perform your "D-during" PMCS (Table 2-1).

    c . Monthly. Always keep in mind the CAUTIONS and WARNINGS. Perform

    your "M-monthly" PMCS (Table 2-1).

    d. I f your equipment fa i ls to operate, troubleshoot with proper equip-ment. Repor t def ic ienc ies as fo l lows:

    (1) (A) Users report in accordance with DA PAM 738-750.

    (2) (P) Users refer to appl icable inspection manuals and work cardsets in the TO 35C2-3 series for periodic requirements and the PMCS Table fordetai led procedures.

    2-5. SPECIAL INSTRUCTIONS. The fol lowing actions apply while performing yourPMCS:

    a . Stop operation immediately i f deficiency is noted during operationwhich would damage the equipment.

    b . Defects discovered during operation of the equipment should be notedfor future correction to be made as soon as operation has ceased.

    2-6. PREVENTIVE MAINTENANCE CHECKS AND SERVICES TABLE. Tab l e 2 - 1 l i s t s a l lPMCS to be performed by the operator.

    NOTE

    I f the equipment must be kept in continuous operation,check and service only those items that can be checkedand serv iced wi thout d is turb ing operat ion. Make thecomplete checks and services when the equipment can beshut down. Inspect shel ter for leaks.

    2-4

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    37/349

    TM 10-5411-200-1

    T.O. 35E4-177-

    For Readiness

    Procedures reporting,

    Check for and have re- equipment is

    Item Interval Item to be paired or adjusted as Not Ready/

    No. B D M Inspected necessary Available if:

    I I

    ELECTRICAL SYSTEM

    1 q q q Circuit breaker Inspect for damage to Circuit panel

    panel assembly door and panel damaged

    2 q q q Panel wiring Inspect for damage or Wiring damaged

    disconnection or disconnected

    3 q q q Light switches Inspect for operation Lights not

    operating

    4 q q q Circuit breakers Inspect for operation, Circuit breakers

    condition, and security not operating

    5 q q q Power entry Inspect for damage to Panel damaged

    panel assembly panel

    6 q q q Receptacles Inspect for operation, Receptacles not

    condition, and security operating

    7 q q q Terminals/ Inspect for operation, Terminals/con-

    Connectors condition, and security nectors not

    operating

    8 q q q Area light Inspect for operation Light not

    assembly operating

    9 q q q Incandescent Inspect for operation Light not

    light assembly operating

    10 q q q Hinged roof Inspect for operation Lights not

    area ceiling operating

    lights

    11 q q q Fixed roof area Inspect for operation Lights not

    ceiling lights operating

    12 q q q Receptacle Inspect for operation Outlets not

    outlets operating

    Table 2-1. Operators Preventive Maintenance Checks and Services

    B - Before D - During M - Monthly

    2-

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    38/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    Table 2-1. Operators Preventive Maintenance Checks and Services (cent)

    B - Before D - During M - Monthly

    For Readiness

    Procedures reporting,

    Check for and have re- equipment is

    Item Interval Item to be paired or adjusted as Not Ready/No. B D M Inspected necessary Available if:

    13 q q q Wall switches Inspect for operation Switches not

    operating

    14 q q q Blackout switch Inspect for operation Switch not

    operating

    15 q q q Wiring Inspect for damage or Wiring damaged

    disconnection or disconnected

    DOOR ASSEMBLIES

    16 q q Personnel and Inspect for operation, Door not operat-

    right cargo condition and security ing, damaged,

    door or insecure

    17 q q Door vent Inspect for operation Vent not operat-

    and condition ing or damaged

    18 q q Door lock Inspect for operation Lock assembly

    assembly and condition not operating or

    damaged

    19 q q Door stop Inspect for operation Stop assembly

    assembly and condition not operating ordamaged

    20 q q Left cargo Inspect for operation Door not operat-door condition, and security ing, damaged, or

    insecure

    21 q q Foot bolt Inspect for operation Foot bolt

    assembly and condition assembly not

    operating or

    damaged

    22 q q Chain bolt Inspect for operation Chain bolt

    assembly and condition. assembly notoperating or

    damaged

    2-6

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    39/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    Table 2-1. Operators Preventive Maintenance Checks and Services (cont)

    B - Before D - During M - Monthly

    For Readiness

    Procedures reporting,

    Check for and have re- equipment is

    Item Interval Item to be paired or adjusted as Not Ready/

    No. B D M Inspected necessary Available if:

    I

    HINGED PANEL LEVELING JACK ASSEMBLIES

    23 q q Hinged panel a. Inspect for sinking a. Shelter not

    leveling jack into ground if shel- level

    assemblies ter not level (check

    frequently during

    rainy conditions).

    b. Inspect for condi- b. Jacks damaged

    tion and security or insecure

    HINGED PANEL ASSEMBLIES24 q q Hinged roof Inspect skin surface for Panel skin

    panels paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    25 q q Support strut Inspect for operation Support strut

    assemblies and condition assemblies not

    operating or

    damaged

    26 q q Hinged endwall Inspect skin surface for Panel skin

    paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    27 q q Endwall close- Inspect skin surface for Panel skin

    out panel paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    28 q q Latches Inspect for operation Latches not

    and condition operating ordamaged

    29 q q Hinged side- Inspect skin surface for Panel skinwalls paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    2-7

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    40/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    Table 2-1. Operators Preventive Maintenance Checks and Services (cont)

    B - Before D - During M - Monthly

    For Readiness

    Procedures reporting,

    Check for and have re- equipment is

    Item Interval Item to be paired or adjusted as Not Ready/No. B D M Inspected necessary Available if:

    30 q q Sidewall close- Inspect skin surface for Panel skin

    out panels paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    31 q q ECU intake Inspect skin surface for Panel skin

    panel paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    32 q q ECU return Inspect skin surface for Panel skinpanel paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    33 q q Hinged floor Inspect skin surface for Panel skin

    panel paint damage, corrosion, corroded,

    cracks, or punctures cracked, or

    punctured

    CONTAINER LIFT JACK ASSEMBLIES

    34 q q q Container lift a. Inspect for sinking a. Shelter notjack assemblies into ground if shel- level

    ter not level (check

    frequently during

    rainy conditions).

    b. Inspect for condi- b. Jacks damagedtion and security or insecure

    FIXED PANEL ASSEMBLIES

    35 q q Personnel door a. Inspect skin surface a. Panel skinend endwall for paint damage, corroded,panel corrosion, cracks, or cracked, or

    punctures punctured

    b. Inspect security of b. Upper mobili-

    upper mobilizer fit- zer fittingting insecure

    36 q q Level assembly Inspect for condition Level assembly

    and security damaged or in-

    secure

    2-8

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    41/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    Table 2-1. Operators Preventive Maintenance Checks and Services (cont)

    B - Before D - During M - Monthly

    B

    For readiness

    Procedures reporting,

    Check for and have re- equipment isItem Interval Item to be repaired or adjusted as Not Ready/

    No. D M Inspected necessary Available if:

    37 l l Folding step Inspect for condition Folding step

    and security damaged or in-

    secure

    38 . l Cargo door end a. Inspect skin surface a. Panel skin

    endwall panel for paint damage, corroded,

    corrosion, cracks, cracked, or

    or punctures punctured

    b. Inspect security of b. Upper mobili-upper mobilizer zer fittings

    fittings insecure

    39 l l Roof panel a. Inspect skin surface a. Panel skin

    for paint damage, corroded,

    corrosion, cracks, cracked, or

    or punctures punctured

    b. Inspect roof hand b. Hand hold

    hold for condition damaged or

    and security insecure

    c. Inspect strike plates c. Strike plate

    for security and loose or

    condition damaged

    40 l l Load balancer Inspect for operation, Load balancer

    and cable condition, and security and cable

    assembly assembly not

    operating,

    damaged, or

    insecure

    41 l l Stowage Inspect for condition Stowage brackets

    brackets and security damaged or in-

    secure

    42 l l Solar bar Inspect for operation, Solar barassembly condition, and security assembly not

    operating,

    damaged or

    insecure

    CHANGE 2 2-9

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    42/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    Table 2-1. Operators Preventive Maintenance Checks and Services (cent)

    B - Before D - During M - Monthly

    B D

    For readiness

    Procedures reporting,

    Check for and have re- equipment isItem Interval Item to be repaired or adjusted as Not Ready/

    No. H Inspected necessary Available if:

    43 q q Floor panel Inspect skin surface Panel skin

    for paint damage, cor- corroded,

    rosion, cracks, or cracked, or

    punctures punctured

    FRAME ASSEMBLY

    44 q q Corner post Inspect for condition Corner post or

    and IS0 fit- and security IS0 fittingting assembly damaged or in-

    secure

    45 q q Camlock and Inspect for operation, Camlock or latch

    latch cam condition, and security cam handle not

    handle operating,damaged, or in-

    secure

    MISCELLANEOUS COMPONENTS

    46 q q Equipment con- Inspect for condition Equipment con-

    tainer and completeness tainer damaged

    or incomplete

    47 q q storm Inspect for condition Storm configura

    configuration and completeness tion components

    components damaged or in-

    complete

    48 l l Support braces Inspect for condition Support braces

    damaged

    49 q q Leveling jack Inspect for condition Leveling jack

    extensions extensions

    damaged

    Skin surfaces that are punctured/damaged will allow

    water entry into honeycomb panel. All punctures/holes of damaged areas must be covered immediately

    pending permanent repair.

    C A U T I O N

    2-10 CHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    43/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    Section III. SETUP OF SHELTER

    2-7. PREPARATION FOR USE.

    Select a site that:

    q Has reasonable maneuvering area for vehicles that will be used for haulingor hoisting shelter.

    q The terrain is firm, well drained, and relatively free of surface rocks or

    stones.

    q The slope of the terrain does not exceed 18 inches (45.7 cm) over the

    projected floor area of the expanded shelter.

    2-8. SHELTER INVENTORY CHECKS.

    a. Expandable shelters are shipped uncrated.

    b. Inspect shelter for damage incurred during shipment. If shelter hasbeen damaged, report damage on SF361, Transportation Discrepancy Report.

    Check equipment against packing list to see if shipment is complete.Report all discrepancies in accordance with instructions of DA PAM 738-750.

    d. Inspect shelter (stowed mode) in accordance with paragraph 2-9.

    2-9. SHELTER INSPECTION CHECKLIST

    LOCATION ITEM ACTION

    1. Fixed personnel a.endwall

    b.

    co

    Power entry panel Inspect connectors for

    damage.

    Identification and Check for legibility orinstruction plates missing plates.

    Personnel door Check for security and

    condition of door, locks,

    seals, and vent.

    CHANGE 2 2-11

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    44/349

    TM 10-5411-200-14

    T.0. 35E4-177-1

    2-9. (cont)

    LOCATION ITEM ACTION

    2. Fixed roof

    3. Fixed cargoendwall

    4. Hinged floors

    d.

    e.

    f.

    g.

    a.

    b.

    c.

    d.

    a.

    b.

    c.

    d.

    e.

    Upper mobilizer

    fittings

    Folding steps

    Components

    Skin

    Roof handhold

    Upper IS0 fittings

    Skin

    Strike plates

    CSC Plate

    Doors

    Upper mobilizer

    fittings

    Components

    Skin

    Skin

    Check for security and

    condition.

    Check for security and

    condition.

    Inspect for missing, bent,

    or damaged components.

    Inspect skin surface for

    paint damage, corrosion,

    cracks, or punctures.

    Check for security and

    operation.

    Inspect fittings for damage.

    Inspect skin surface for

    paint damage, corrosion,

    cracks, or punctures.

    Check for security and

    condition.

    Check for legibility ormissing plate.

    Check for security and con-dition of doors, locks,

    seals, and vents.

    Check for security and

    condition.

    Inspect for missing, bent,

    or damaged components.

    Inspect skin surface for

    paint damage, corrosion,

    cracks, or punctures.

    Inspect skin surface for

    paint damage, corrosion,

    cracks, or punctures.

    2-12 CHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    45/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    2-9. (cont)

    LOCATION ITEM ACTION

    5. Fixed floor base a. Lower mobilizer Check for security and

    frame fittings condition.

    b. Lower ISO fittings Inspect fittings for damage.

    c. Frame edge and Inspect for damage.

    fork lift opening

    6. Corner posts Components Inspect for missing, bent,

    or damaged components.

    2-10. SHELTER HANDLING

    Do not use handling equipment with capacity of less

    than gross weight of system. Do not allow shelter

    to swing back and forth when suspended. Failure to

    observe this WARNING may result in damage to equipment

    or severe injury or death to personnel.

    NOTE

    Dollyset M832 mobilizer used only if gross weight of

    shelter system is 10,000 pounds (4546 Kg) or less.

    Dollyset XM1022 or hoisting sling (with cable breaking

    strength of 35,000 pounds) used if gross weight of shelter

    system is over 10,000 pounds (4546 kg).

    When using fork lift, make sure it has a minimum tine

    length of six feet. Use inner slots for fork liftingan empty shelter only.

    Use 20-foot container lift sling (bottom lift, type II,

    with a 20 long ton safe working load) with aluminum

    spreader, Appendix D.

    2-13

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    46/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    2-10. (cont)

    SHACKLE Attachment

    a. Hoisting from upper ISO fittings.

    CAUTION

    Do not attach hoisting sling or ISO lifting device

    to handling equipment in such a manner that angle

    between hoist line and shelter is less than 45

    degrees. Any angle less than 45 degrees will cause

    an excessive strain which could damage shelter.

    (1) Attach hoisting Sling to crane or equivalent and four upper IS0fittings.

    (2) Hoist shelter and position to desired location.

    b. Hoisting from lower IS0 fittings.

    (1) Attach IS0 lifting device to crane or equivalent and four lowerIS0 fittings.

    (2) The IS0 lifting device should contact four lower IS0 fittings only

    and not make any other contact with shelter.

    2-14 CHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    47/349

    TM 10-5411-200-14

    T.O. 35E4-177-I

    2-10, (cont)

    (3) Terminal fittings shall be installed so that lifting forces are

    exerted not more than 1-1/2 in. (38 mm) away from ISO fittings.

    (4) Hoist shelter and position to desired location.

    c. Fork lifting from fork lift slots in base frame.

    (1) Fork lift arms shall be at least 6 ft (1.8 m) long.

    (2) Use care when inserting fork lift arms in fork lift slots.

    (3) Use inner slots for fork lifting an empty shelter only.

    (4) Use outer slots for fork lifting shelter with maximum payload.

    d. Dollyset lifting from mobilizer fittings.

    (1) Separate Dollyset sections and prepare for use observing allrecommendations of Dollyset technical manual.

    (2) Position. Dollyset sections at ends of shelter adjacent tomobilizer fittings at shelter endwalls.

    (3) Position Dollyset brackets to connect with shelter mobilizerfittings and secure Dollyset to shelter.

    2-15

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    48/349

    TM 10-5411-200-14

    T.O. 35E4-177-1

    2-10. (cont)

    (4) Operate Dollyset according to Dollyset technical manual to

    raise shelter to towing height.

    (5) Connect towing equipment to Dollyset tow bar.

    (6) When shelter is in desired position, operate Dollyset to lower

    shelter and remove Dollyset sections.

    e. Dollyset lifting from ISO fittings.

    (1) Separate Dollyset sections and prepare for use observing all

    recommendations of Dollyset technical manual.

    (2) Position Dollyset sections at ends of shelter adjacent to ISO

    fittings at shelter endwalls.

    (3) Position Dollyset brackets to connect with shelter IS0 fittings

    and secure Dollyset to shelter.

    (4) Operate Dollyset according to Dollyset technical manual to

    raise shelter to towing height.

    (5) Connect towing equipment to Dollyset tow bar.

    (6) When shelter is in desired position, operate Dollyset to lower

    shelter and remove Dollyset sections.

    f. Trailer or flatbed transporting.

    (1) Using four 14-foot chains and four binders, secure shelter to

    trailer or flatbed as shown in method 1.

    (2) Using two 20-foot chains and two binders or four 6-foot chains

    and two binders, secure shelter to trailer or flatbed as shown in method 2.

    2-16

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    49/349

    TM 10-5411-200-14T.O. 35E4-177-1

    2 - 1 0 . ( c o n t )

    g. Rai l road t ranspor t ing.

    (1) P lace f loor t imbers a long the f ront and rear o f the shel tercontac t ing lower ISO f i t t ings .

    NOTE

    Make sure timber is new and has no structuralweakness.

    (2) Tie the shelter down to the retaining brackets on the rai lroadcar with 1/2-inch diameter wire rope and turn buckles.

    (3) Place 8 inch by 8 inch blocking t imbers on the rai lroad car f loorwi th the edge gra in la id f la twise.

    (4) P lace at leas t four 4 inch by 5 inch ver t ica l post t imbers wi thedge grain oriented fore and aft at each end of the shelter.

    (5) Bol t the ends of the f loor t imbers to the ver t ica l post t imbersusing 3/4-inch diameter bolts.

    (6) Spike or na i l the ver t ica l post t imbers through the re ta in ingbrackets on the rai lroad car to prevent vert ical movement.

    2-17

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    50/349

    5411-01-136-9838PART NO: 5-4 3118

    81337

    5411-01-136-9838

    81337PART NO: 5-4-3201

    5411-01-294-9866

    5411-01-294-9866

    M 10-5411-200-14.O. 35E4-177-1

    -11. LOCATION OF IDENTIFICATION AND INSTRUCTION PLATES. The following figures provide location andontents of identification and instruction plates for the shelter.

    -18 CHANGE 8

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    51/349

    TM 10-5411-200T.O. 35E4-17

    2-11. LOCATION OF IDENTlFlCATlON AND INSTRUCTION PLATES. (Cont)

    Sand Paint Data Plate (with scuff strip)

    THIS SHELTER PAINTED WITH CARC PAINTPAINT

    TYPE

    MIL SPEC

    COLOR

    COLOR CODE

    FED-STD-595INTERIORPAINT

    EXTERIORPAINT

    EPOXY MIL-C-22750 17925WHITE

    ALIPHATICPOLYURETHANE

    MIL-C-46168 33303SAND

    PRIMER EPOXY MIL-P-53022

    FLOORPAINT

    WALKWAYCOMPOUND

    MIL-W-5044TYPE I GRAY

    26251

    FLOOR

    PAINT

    WALKWAY MIL-W-5044

    COMPOUND TYPE II GRAY

    Location of Identification and Instruction Plates

    26251

    Sand Paint Data Plate (without scuff strip)

    THIS SHELTER PAINTED WITH CARC PAINT

    INTERIOR

    PAINT

    EXTERIORPAINT

    PRIMER

    FLOORPAINT

    PAINTTYPE

    EPOXY

    ALIPHATICPOLYURETHANE

    EPOXY

    WALKWAYCOMPOUND

    MIL SPECCOLOR

    COLOR CODEFED-STD-595

    MIL-C-22750 17925

    WHITE

    MIL-C-46168 33303SAND

    MIL-P-53022

    MIL-W-5044TYPE I GRAY

    26251

    Location of Identification and Instruction Plates

    CHANGE 8 2-

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    52/349

    TM 10-5411-200-14T.O.35E4-177-1

    2-11. LOCATION OF IDENTIFICATION AND INSTRUCTION PLATES. (Cont)

    Camouflage Paint Data Plate (with scuff strip)

    THIS SHELTER PAINTED WITH CARC PAINT

    INTERIORPAINT

    EXTERIORPAINT

    PRIMER

    FLOOR

    PAINT

    FLOORPAINT

    PAINTTYPE

    EPOXY

    ALIPHATICPOLYURETHANE

    E P OX Y

    WALKWAY

    COMPOUND

    WALKWAYCOMPOUND

    MIL SPECCOLOR

    MIL-G22750GLOSS WHlTE

    MlL-C-46168GREEN 383BROWN 383BLACK

    MIL-P-53022

    MIL-W-5044

    TYPE I GRAY

    MIL-W-5044TYPE II GRAY

    COLOR CODEFED-STD-595

    17925

    340943005137030

    26251

    26251

    Camouflage Paint Date Plate (without scuff strip)

    THIS SHELTER PAINTED WITH

    CARCPAINT

    PAINT MIL SPEC COLOR CODETYPE COLOR FED-STD-595

    INTERIOR EPOXY MIL-C-22750 17925PAIN-ILL WHITE

    EXTERIORPAINT

    ALIPHATICPOLYURETHANE

    MIL-C-46168GREEN 383 34094BROWN 383 30051BLACK 37030

    PRIMER EPOXY MIL-P-53022

    FLOOR WALKWAY MIL-00-5044 26251P A I N T COMPOUND TYPE I GRAY

    -18.2 CHANGE 8

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    53/349

    TM 10-5411-200-1T.O. 35E4-177-

    2-11. LOCATION OF IDENTIFICATION AND INSTRUCTION PLATES. (Cont)

    Green Paint Data Plate (with scuff strip)

    THIS SHELTER PAINTED WITH CARC PAINT

    INTERIORPAINT

    EXTERIORPAINT

    PRIMER

    FLOORPAINT

    FLOORPAINT

    PAINTTYPE

    EPOXY

    ALIPHATICPOLYURETHANE

    EPOXY

    WALKWAYCOMPOUND

    WALKWAYCOMPOUND

    MIL SPECCOLOR

    MIL-C-22750WHITE

    MIL-C-46168GREEN 383

    MIL-P-53022

    MIL-W-5044TYPE I GRAY

    MIL-W-5044NPE II GRAY

    COLOR CODEFED-STD-595

    17925

    34094

    26251

    26251

    Green Paint Data Plate (without scuff strip)

    THIS SHELTER PAINTED WITH CARC PAINT

    INTERIORPAINT

    EXTERIORPAINT

    PRIMER

    PAINTTYPE

    EPOXY

    ALIPHATICPOLYURETHANE

    EPOXY

    MIL SPECCOLOR

    MIL-C-22750WHITE

    MIL-C-46168GREEN 383

    MIL-P-53022TYPE I

    COLOR CODEFED-STD-595

    17925

    34094

    FLOOR WALKWAY MIL-W-5044PAINT COMPOUND TYPE I GRAY

    26251

    CHANGE 8 2-18.3/(2-18.4 blan

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    54/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    55/349

    TM10-5411-200-14T.O. 35E4-177-1

    2-11. (cont )

    ERECTION SEQUENCE

    THE SHELTER JACKS ARE REMOVED FROM THEIR STOWED SLIDE THE HINGED-ROOF OUTWARD WITH SOLAR BALOCATION AND ATTACHED TO THE FOUR CORNERS RAISE PARTIALLY TO PROVIDE ACCESS TO THEOF THE MODULE. ROOF STRUTS STOWED ON THE INSIDE OF THE

    THE MODULE IS LEVELED USING THE BULLS EYE LEVELSLOCATED NEAR THE JACKS.

    HINGED ROOFLOWER AND PIN ROOF STRUTS

    REMOVE CABLE RETAINING PINS INSIDE SHELTER. DlSENGAGE RAISE THE HINGED ROOF AND REST ON ROOF STRUT

    EXTERNAL FLOOR LOCKS AND USE LOCKING MECHANISM SWING THE HINGED ENDWALLS OUT TO THE OPENTO FREE FLOOR ENGAGEMENT POSITION

    LOWER THE FLOOR TO THE EXTENT OF THE CABLE TRAVEL (1 1/2"BELOW LEVELS)

    RAISE THE HINGED SIDEWALL ANDCONNECT 2 SUPPORT BRACES.INSTALL 2 SUPPORT JACKS.

    USING THE SUPPORT JACKS, RAISE THE HINGED FLOOR ANDSlDEWALL TO MATE THE HINGED ENDWALLS. LINE UPPOSITIONING MARKS.

    REMOVE THE STRUTS FROM THE UPRIGHT POSITION ALLOWINGTHE HINGED ROOF TO REST ON THE HINGED SIDEWALL ANDENDWALLS

    REPEAT SEQUENCE FOR OPPOSITE SIDE. STOW THE STRUTS ON THE HINGED ROOF. ENGAGE ALLPANEL LATCHES TO COMPRESS THE SEALS.

    L o c a t i o n o f I d e n t i f i c a t i o n a n d I n s t r u c t i o n P l a t e s

    2-19

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    56/349

    TM 10-5411-200-14T.O. 35E4-177-1

    2-12. SHELTER EXPANSION

    NOTE

    Four personnel are required to perform the following

    procedures.

    a. Remove four container lift jacks from inside of personnel and right

    cargo doors by turning locking handle to loosen jack attachment insert and

    removing safety pin.

    b. Position jacks at each corner of shelter.

    NOTE

    Stencil on jack indicates handle rotation to raise orlower jack.

    c. Rotate handle to raise jack until insert will enter lower ISO

    fitting and upper jack attachment engages jack support bracket On corner

    post .

    d. Turn locking handle to rotate insert in ISO fitting. Install safety

    pin.

    e. Repeat steps c and d at three remaining corner posts.

    2-20

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    57/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4

    T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 2 . ( c o n t )

    f . Ra i s e a l l j a c k s s i mu l t a n eo us l y a t e a c h c o r n e r o f s h e l t e r t o p r e v e n te x c e s s i v e s t r a i n o n j a c k s o r s h e l t e r .

    NOTE

    T h e s h e l t e r s h a l l b e r a i s e d a mi n i mu m o f 3i n c h e s ( 7 . 6 c m) o f f g r o u nd .

    g . Wa t c h l e v e l i n d i c a t o r s a t e a c h c o r n e r a n d a d j u s t j a c k s a s n e e d e d i no r d e r t o l e v e l s h e l t e r .

    h . Re mo v e q u i c k r e l e a s e p i n s f r o m s t o p p l a t e s o n b o t h l o a d b a l a n c e r s( i n s i d e s h e l t e r ) o f t h e s i d e o f t h e s h e l t e r b e i n g e x p a n de d t o p e r mi t s u p p o r tc a b l e t r a v e l .

    ST O P PL AT EWI T H OU I C KR EL E A S E P I N

    2 - 2 1

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    58/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 2 . ( c o n t )

    WA R N I N G

    Ex p a n d a b l e s e c t i o n ( h i n g e d f l o o r a n d h i n g e d s i d e wa l l

    t o g e t h e r ) we i g h s 7 0 0 p o u n d s ( 3 1 8 k g ) . Do n o t s t a n dd i r e c t l y i n f r o n t o f h i n g e d s e c t i o n .

    i . Ra i s e c a m l o c k h a n d l e s o n c o r n e r p o s t s a n d r o t a t e a s i n d i c a t e d t od i s e n g a g e h i n ge d f l o o r l o c k s .

    Ca r e f u l l y l o we r h i n g e d f l o o r t o t h e e x t e n t o f s u p p o r t c a b l e t r a v e l( 1 - 1 / 2 i n . ( 3 . 8 c m) b e l o w l e v e l ) .

    W A R N I N G

    T h e s t o p p l a t e c a b l e a s s e mb l y i s a s p r i n g p o we r e dme c h a n i s m. Pe r s o n a l i n j u r y o r d ea t h ma y r e s u l t i f

    t wo qu i c k r e l e a s e p i n s a r e no t i n s t a l l e d i n t h es t o p p l a t e s .

    k . I n s t a l l . t wo qu i c k r e l e a s e p i n s i n s t o p p l a t e s o n l o a d b a l a n c e r s( i n s i d e s h e l t e r ) t o p r e v e n t r e t u r n o f s u p po r t c a b l e .

    l . Re mo v e t wo s u p p o r t b r a c e s f r o m e q u i p me n t c o n t a i n e r .

    m. Ra i s e h i n g e d s i d e wa l l a n d h o l d i n p o s i t i o n .

    n . I n s t a l l t h e t wo s u p p o r t b r a c e s i n b r a c e c u p s o n h i n g e d f l o o r a n ds i d ewa l l b e h i n d s u p p o r t c a b l e .

    o . Re mo v e t wo l e v e l i n g j a c k s f r o m i n s i d e o f l e f t c a r g o d o o r .

    p . Po s i t i o n j a c k s a t e a c h c o r n e r o f e x p a n d e d s i d e .

    2 - 2 2 C HA NGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    59/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    60/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 2 . ( c o n t )

    WA R N I N G

    2 - 1 2 .

    Do o r v e n t s a r e s p r i n g l o a d e d t o s wi n g u p wa r d . T o p r e v e n t i n j u r y ,h o l d d o o r v e n t s h u t wh i l e u n l a t c h i n g a l l t h e r e t a i n i n g c l i p s .

    ( c o n t )

    t . P u s h t w o h a n d l e s o f s o l a r b a r o n i n s i d e o f f i x e d r o o f t o t h e i r e x t e n t s i mu l t a n e o u s l y t o s l i d eh i n g e d r o o f o u t wa r d ,

    C A U T I O N

    S u p p o r t i n n e r t u b e wh i l e d i s e n g a g i n g s u p p o r t s t r u t s f r o m s t o wa g e b r a c k e t s .

    u . P u l l l o c k p i n t o f r e e s u p p o r t s t r u t s f r o m s t o wa g e b r a c k e t a n d s wi n g do wn wa r d ,

    2 - 2 4 C h a n g e 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    61/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 2 . ( c o n t )

    v . E x t e n d

    a r e i n a l i g n m e n t .

    i n ne r t u ba o f s t r u t a n d i n s e r t l o c k p i n wh e n p i n ho l e s i n i n n e r t u b e an d o u t e r t u b

    C A U T I O N

    Do n o t f o r c e h i n ge d r o o f t o f u l l h e i g h t . T h i s c o u l d c au s e d a ma ge t o t h er o o f a n d s i d e wa l l s e a l . E n s u r e t h a t t h e h i n g e d r o o f w i l l c l e a r t h e h i n g e ds i d e we l l p r i o r t o l i f t i n g .

    w. Ra i s e h i n g e d r o o f t o f u l l h e i g h t o f s t r u t s u s i n g a l l f o u r p e r s o n n e l : T wo o n s u p p o r t s t r u t s ; t wt o a s s i s t a t r o o f .

    C h a n g e 2 2 - 2 4 . 1 / ( 2 - 2 4 . 2 b l a n k

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    62/349

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    63/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 2 . ( c o n t )

    x . Swi n g h i n g e d e n d wa l l s o u t t o o p e n p o s i t i o n .

    y . Ro t a t e h a n d l e s t o r a i s e b o t h j a c k s u n t i l p o s i t i o n i n g ma r k s o n h i n g e de n d wa l l s a n d h i n g e d s i d e wa l l a r e i n a l i g n me n t .

    C A U T I O N

    DO n o t c o n t i n u e t o j a c k s i n c e t h i s ma y c a u s es t r u c t u r a l d a ma g e t o h i n g e d e n d wa l l .

    z . Us e s u p p o r t s t r u t s t o l o we r h i n g e d r o o f t o r e s t o n h i n g e d e n d wa l l sa n d s i d e wa l l .

    a a . Re mo v e l o c k p i n s f r o m s u p p o r t

    s t r u t s . Co mp r e s s s u p p o r t s t r u t s a n ds e c u r e i n s t o wa g e b r a c k e t s o n h i n g e dr o o f wi t h l o c k p i n s .

    a b . A d j u s t l e v e l i n g j a c k t o ma k e s u r ep o s i t i o n i n g ma r k s o n h i n g e d r o o f a n d h i n g e ds i d e wa l l a r e p r o p e r l y a l i g n e d .

    a c . Ob t a i n f o u r r e mo v a b l e l a t c h e s f r o me q u i p me n t c o n t a i n e r a n d i n s t a l l t wo o n h i n g e ds i d e wa l l a n d t wo o n h i n g e d e n d wa l l s .

    a d . E n g a g e a l l p a n e l l a t c h e s t o c o mp r e s s

    s e a l s . E n g a g e n o n r e mo v a b l e l a t c h e s f i r s t t h e nr e mo v a b l e l a t c h e s .

    a e . V i s u a l l y c h e c k t o ma k e s u r e a l l s e a l sa r e p r o p e r l y c o mp r e s s e d .

    a f . Re mo v e s u p p o r t b r a c e s .

    a g . Re p e a t s t e p s h t h r o u g h a f t o e x t e n do t h e r e x p a n d a b l e s i d e , t h e n s t o w s u p p o r t b r a c e si n e q u i p me n t c o n t a i n e r .

    2 - 2 5

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    64/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E 4 - 1 7 7 - 1

    2 - 1 3 . CE I L I NG L I GHT S AND UT I L I T Y OUT L E T S I NS TA L L A T I ON

    a . Ce i l i n g l i g h t i n s t a l l a t i o n .

    W A R N IN G

    I n t h e e v e n t o f l a mp b r e a k a g e , c a r e mu s t b e t a k e n i nr e mo v a l o f b r o k e n g l a s s f r a g me n t s a n d wh i t e p h o s p h o r o u sd u s t t h a t ma y b e d i s p e r s e d wi t h i n f i x t u r e . I n h a l a t i o no f p h o s ph o r o u s d u s t c o u l d c a us e d an g e r o u s I n j u r y .

    ( 1 ) S e t c i r c u i t b r e a k e r C B 6 t o o f f p o s i t i o n .

    ( 2 ) R e mo v e p o we r c o r d f r o m s t o wa g e c l i p o n c e i l i n g .

    ( 3 ) De p r e s s p l u n g e r l o c k i n f i x e d r o o f l i g h t s t o wa g e b r a c k e t .

    ( 4 ) Mo v e e n t i r e l i g h t f i x t u r e l e n g t h wi s e t o wa r d p o we r c o r d e n d t od i s e n g a g e l i g h t f r o m t h e f o u r c a p t i v e s t u d s i n f i x e d r o o f .

    ( 5 ) Mo v e l i g h t f i x t u r e i n t o e x p a n d a b l e s e c t i o n a n d ma t e w i t h f o u rc a p t i v e s t u ds i n h i n g e d r o o f .

    ( 6 ) A f t e r c e i l i n g l i g h t i s p r o p e r l y s e a t e d , s e c u r e f i x t u r e b ymo v i n g u n t i l s p r i n g l o a d e d p l u n g e r e n g a g e s .

    ( 7 ) P l u g p o we r c o r d i n t o c o n n e c t o r , a n d t wi s t o n e - q u a r t e r t u r n t o

    l o c k i n .

    ( 8 ) Re p e a t t h i s p r o c e d u r e f o r e a c h o f f i v e r e ma i n i n g c e i l i n gl i g h t s .

    b . Ca b l e a n d r e c e p t a c l e a s s e mb l y i n s t a l l a t i o n .

    2 - 2 6

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    65/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 3 . ( c o n t )

    ( 1 ) R e l e a s e c a p t i v e f a s t e n e r s a n d r e p o s i t i o n r e c e p t a c l e s f r o ms t o we d p o s i t i o n o n h i n g e d e n d wa l l t o o p e r a t i n g p o s i t i o n o n h i n g e d e n d wa l l s a n dh i n ge d s i d ewa l l s .

    ( 2 ) P o s i t i o n r e c e p t a c l e s wi t h p o we r c o r d s f a c i n g u p .

    ( 3 ) S e c u r e f l e x i b l e c a b l e wi t h v e l c r o s t r a p s .

    2 - 1 4 . A RE A L I GHT I NS T AL L A T I ONa . L o o s e n wi n g n u t s a n d r e mo v e a r e a l i g h t f r o m s t o wa g e l o c a t i o n i n s i d es h e l t e r o n p e r s o n n e l e n d p a n e l .

    D o n o t

    NOTE

    r e mo v e wi n g n u t s f r o m s c r e ws .

    2 - 2 7

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    66/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 4 . ( c o n t )

    b . Re mo v e b u l b f r o m e q u i p me n t c o n t a i n e r a n d s c r e w b u l b i n t o l i g h ts o c k e t .

    c . I n s t a l l t h e a r e a l i g h t o n t h e f i x e d p e r s o n n e l o r c a r g o e n d wa l l b yma t i n g t h e h e a d e d e n d o f t h e mo u n t i n g s c r e ws wi t h t h e b r a c k e t s p r o v i d e d .

    d . Se c u r e t h e a r e a l i g h t t o t h e mo u n t i n g b r a c k e t s b y t i g h t e n i n g t h e t wowi n g n u t s .

    NOTE

    Wh e n t h e a r e a l i g h t i s i n s t a l l e d a t c a r g o e n d o fs h e l t e r t h e c a b l e i s r o u t e d o v e r t h e t o p o f t h es h e l t e r . T h e e x c e s s c a b l e s l a c k s h o u l d b e n e a t l y

    c o i l e d o n t h e a r e a l i g h t p o s t s o t h a t i t d o e s n o tp r e s e n t a h a z a r d t o p e r s o n n e l .

    e . Co n n e c t c a b l e i n t o J 3 o r J 4 c o n n e c t o r s o n t h e p o we r e n t r y p a n e l .

    2 - 1 5 . E X T E R NA L C ON NE C T I ON S .

    2 - 2 8

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    67/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 5 . ( c o n t )

    a . S h e l t e r g r o u n d i n g

    N O T E

    S h e l t e r i s g r o u n d e d t h r o u g h e x t e r n a l l y c o n n e c t e d p o we r s u p p l y . A d d i t i o n a lg r o un d i n g , d e p en d i n g o n l o c a l c o n d i t i o ns , ma y b e i n s t a l l e d b y u t i l i z i n go p t i o n a l g r o u n d i n g r o d , A p p e n d i x D. Co n s u l t a q u a l i f i e d e l e c t r i c i a n f o rp r o p e r g r o u n d i n g p r o c e d u r e s r e q u i r e d f o r s u r r o u n d i n g s o i l c o n d i t i o n s .

    ( 1 ) D r i v e g r o u n d r o d i n t o e a r t h a t a s u i t a b l e l o c a t i o n t h a t p e r m i t s g r o u n d c a b l e a t t a c h e d t or o d t o r e a c h g r o u n d s t u d o n p o we r e n t r y p a n e l .

    ( 2 ) On p o we r e n t r y p a n e l r e mo v e n u t , s t a r w a s h e r , a n d f l a t wa s h e r o n s t u d .

    ( 3 ) C o n n e c t g r o u n d c a b l e c o n n e c t o r t o s t u d a n d s e c u r e wi t h wa s h e r , s t a r w a s h e r , a n d n u t .

    ( 4 ) Ch e c k a l l c o n n e c t i o n s f o r s e c u r i t y ,

    b . I n p u t p o we r c o n ne c t i o n

    W A R N I N G

    ( 1 )

    ( 2 )

    Do n o t a t t e mp t c o n n e c t i o n o f l i v e l i n e t o p o we rp o w e r s o u r c e o r g e n e r a t o r b e f o r e p r o c e d u r e .

    P o we r s u p p l y s h a l l b eCi r c u i t B r e a k e r P a n e l

    C A U T I O N

    e n t r y p a n e l . De a c t i v a t e

    1 2 0 / 2 0 8 V a t , 4 wi r e wi t h 1 g r o u n d f o r Mo d e l NQOBo r 1 2 0 / 2 0 8 Va c , 4 wi r e wi t h 4 g r o u n d s f o r Mo d e l

    NQOD Ci r c u i t B r e a k e r P a n e l o r d a ma g e t o e q u i p me n t w i l l r e s u l t .

    T u r n a l l c i r c u i t b r e a k e r s t o OF F p o s i t i o n ,

    N O T E

    Ma k e c e r t a i n t h a t p o we r e n t r y p a n e l a n d p o we r s u p p l y c a b l e a r e t e r mi n a t e dwi t h s a me t y p e o f c o n n e c t o r .

    Co n n e c t p o we r s u p p l y c a b l e t o p o we r e n t r y p a n e l a t c o n n e c t o r ( J 1 ) .

    C h a n g e 2 2 - 2 9

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    68/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 5 . ( c o n t )

    ( 3 ) T u r n MAI N c i r c u i t b r e a k e r t o ON p o s i t i o n a n d o b s e r v e a n y u n u s u a lc o n d i t i o ns .

    ( 4 ) T u r n r e ma i n i n g c i r c u i t b r e a k e r s t o ON p o s i t i o n o n e a t a t i me a n do b s e r v e an y - u n u s u a l c o n d i t i o n s .

    c . ECU Co n n e c t i o n .

    ( 1 ) T u r n CB1 t o OF F p o s i t i o n .

    ( 2 ) Co n n e c t ECU s u p p l y c a b l e t o

    ( 3 ) T u r n CB1 t o ON p o s i t i o n a n d

    2 - 1 6 . CLOSI NG SEQUENCE

    N O T E

    F o u r p e r s o n n e l a r e r e q u i r e df o l l o wi n g p r o c e d u r e s .

    c o n n e c t o r ( J 2 ) .

    o b s e r v e f o r a n y u n u s u a l c o n d i t i o n s .

    t o p e r f o r m t h e

    Ma k e s u r e h i n g e d f l o o r i s c l e a r o f i t e ms o r d e b r i sa n d f l o o r h i n g e s a r e c l e a n o f s a n d o r d i r t .

    Ma k e s u r e t o p o f h i n g e d r o o f i s c l e a r o f i t e ms ,d e b r i s , s n o w, o r i c e a n d h i n g e d f l o o r e x t e n s i o n i sc l e a r o f f o r e i g n ma t t e r , s n o w o r i c e .

    Do n o t a t t e mp t t o l o we r o r r e mo v e c o n t a i n e r l i f t j a c k s u n t i l a f t e r p r o c e d u r e s i n s t e p s a t h r o u g h qh a v e b e e n c o mp l e t e d .

    a . Re mo v e p o we r c o r d f r o m p o we r e n t r y p a n e l .

    b . Re mo v e E CU i n t a k e a n d r e t u r n p a n e l s a n d r e p l a c e wi t h c l o s e o u t p a n e l s .

    c . Re mo v e h i n g e d r o o f a r e a c e i l i n g l i g h t s a n d r e c e p t a c l e s f r o m e x p a n d e ds e c t i o n a n d r e t u r n t o t h e i r s t o wa g e p os i t i o n .

    d . Re mo v e a n d s t o w l a t c h p l a t e s i n e q u i p me n t c o n t a i n e r .

    2 - 3 0 CHANGE 2

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    69/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 6 . ( c o n t )

    WAR N I N G

    I t i s e s s e n t i a l t h a t t h e c o mp l e t e l a t c h i sp r e s s e d f l a t i n t o t h e p an .

    e . Re l e a s e a l l l a t c h e s b e t we e n h i n g e d s i d e wa l l , e n d wa l l , r o o f , a n df l o o r .

    f . L o we r s u p p o r t s t r u t s a n d r a i s e h i n g e d r o o f t o f u l l e x t e n t o f s t r u t .

    8 . Di s e n g a g e q u i c k r e l e a s e p i n a n d s t o p p l a t e f o r c a b l e o n l o a db a l a n c e r .

    h . L o we r h i n g e d f l o o r w i t h l e v e l i n g j a c k s .

    i . F o l d i n h i n g e d e n d wa l l t o r o o f b e a m a n d h o l d i n p l a c e wi t h v e l c r os t r a p s .

    j . L o we r h i n g e d r o o f b y u s i n g s u p p o r t s t r u t s a n d p e r s o n n e l a t e a c h e n do f r o o f .

    k . S l i d e h i n g e d r o o f i n wa r d t o s t o wa g e p o s i t i o n b y p u l l i n g d o wn o ns o l a r b a r h an d l e s .

    l . Re mo v e l e v e l i n g j a c k s s u p p o r t i n g h i n g e d f l o o r a n d s t o w o n l e f t c a r g od o o r .

    m. Re mo v e s i d e wa l l s u p p o r t b r a c e s a n d s t o r e i n e q u i p me n t c o n t a i n e r .

    WA R N I N G

    T o a v o i d i n j u r y , b e c a r e f u l n o t t o g e t c a u g h t b e t we e nc a b l e a n d s i d e wa l l p a n e l . Do n o t a t t e mp t t o c o n t r o lp a n e l i f I t i s a c c i d e n t a l l y d r o p p e d .

    n . F o l d d o wn h i n g e d s i d e wa l l o n t o h i n g e d f l o o r . A l l o w wa l l t o f r e ef a l l b e f o r e i t c o me s t o t h e s a me p l a n e a s t h e c a b l e s . T r a p p e d a i r a c t s a s ac u s h i o n .

    o . P o s i t i o n c a ml o c k s s o h a n d l e s a r e v e r t i c a l a n d o u t wa r d .

    f i r s t .Ra i s e h i n g e d f l o o r a n d c a ml o c k t o c o r n e r p o s t . E n g a g e l o we r l o c k s

    Ma k e s u r e p i n s a r e i n h o l e s ,

    C h a n g e 6 2 - 3 1

  • 8/14/2019 TM 10-5411-200-14 SHELTER EXPANDABLE TWO-SIDED

    70/349

    T M 1 0 - 5 4 1 1 - 2 0 0 - 1 4T . O. 3 5 E4 - 1 7 7 - 1

    2 - 1 6 . ( c o n t )

    NOTE

    I f h i n g ed f l o o r a n d c o r n e r p o s t b i n d , r e l e v e l s h e l t e r .

    q . Cl o s e c a r g o d o o r s .

    r . Re mo v e c o n t a i n e r l i f t j a c k s a n d s t o w o n p e r s o n n e l a n d r i g h t c a r g od o o r s .