Tiraz irdie, Jennifer Hollenbach, Lynn Watney, Eugene ......Tiraz irdie, Jennifer Hollenbach, Lynn...

1
US EPA Class VI CO 2 Injecon Permit — Requirements and Lessons Learnt from the Wellington, Kansas, Project Tiraz Birdie, Jennifer Hollenbach, Lynn Watney, Eugene Holubnyak, Mina Fazelalavi, Tandis Bidgoli, Dana Wreath Introducon The Wellington demonstraon project involves injecng 26 KTons of CO 2 in the cam- bro-ordovician Arbuckle aqui- fer in central Kansas. A US EPA Class VI injecon permit is re- quired for CO2 sequestraon in saline aquifers. The primary objecves of the EPA are to protect Underground Sources of Drinking Water (USDW; TDS < 10000 mg/l), and to prevent any injected CO2 from escap- ing into the atmosphere with- in the Area of Review (AoR). The AoR is defined as the larg- er of the maximum extent of a) the CO2 plume, or b) the pressure boundary within which brines from the injec- on zone can migrate into overlying USDW via abandoned wells, leakage in the in- jecon well, or breach of the confining zone. Plans Key Challenges A- Operang Require- ments No key challenges B– Area of Review and Cor- recve Acon High resoluon characterizaon of injecon and confining zones, addressing uncertaines in formaon petrophysical properes, and addressing seismic risk C—Tesng and Monitoring Region wide (indirect) monitoring of plume and pressure front D—Well Plugging No key challenges E—Post-Injecon Site Care Reducing default monitoring period of 50 years F— Emergency and Reme- dial Response Develop project specific plans to ensure safe and efficient injec- on, and design/installaon of ground-moon sensing equipment G—Construcon Details No key challenges H— Financial Assurance Reducing default obligaon of approximately $70 Million I— Smulaon Program No key challenges Permit Timeline The Wellington permit submial was the first applicaon for a newly constructed CO2 sequestraon well since promulgaon of the Class VI Rule in 2011. During the applicaon process, it was realized that were many tech- nical issues for which guidance and precedence was lacking. For example, the Class Rule did not have any for- mal regulaons/guidelines for addressing the subject of induced seismicity. As shown in the permit meline below, the Wellington team had to expend me and budget on many acvies that were unancipated at com- mencement of the project. Several of the first-of-a-kind studies conducted in pursuit of the permit and the ac- companying reports are expected to serve as a guide and template for future CO2 sequestraon projects. Class VI Based Allowable Increase in Pore Pressure Class VI pressure limitaons may restrict commercial scale CO 2 sequestraon to western half of the state Project Task EPA Cost Correcve Acon $0 Well Plugging $0.22M Post-Injecon Site Care $0.29M Site Closure $1.01M Emergency Response $68.48M Total $70.01M Emergency Scenarios Well Integrity Failure Equipment Failure Water Quality Changes Migraon of CO 2 out of Injecon Zone Release of CO 2 to Surface Natural Disaster Induced Seismicity Event Wellington Operang Plan For Safe and Efficient Injecon Monitoring Based Rapid Response Plan Wellington Seismic Acon Plan Injecon Control Plan Emergency Remedial Response Plan A network of 15 seismometers was installed to provide early warning of deteriorang condions. Correcve acons are to be implemented at pre-set thresholds as specified in the Wel- lington Seismic Acon Plan. Collecvely, these measures will ensure safe injecon at the site. The seismometers have been monitoring ground moon since 2015 and assist in seismic re- search. Indirect Direct Plume 2D and 3D Seismic Surveys, Connuous Acve Source, Crosswell Seismic U-Tube Pressure Downhole Pressure & temperature Passive Seismic, InSAR and cGPS Injecon Zone monitoring Well Integrity Temperature log, annulus pressure, pressure fall- off, corrosion coupon Wellhead Injecon rate and volume (flow meter), pressure, temperature Annulus Annulur pressure, fluid volume Arbuckle, Mississippi- an, and Wel- lington For- maon Caons: Al, Ba, Mn, As, Cd, Cr, Cu, Pb, Sb Se, and Tl , Ca, Fe, K, Mg, Na, Si Anions: Br, Cl, F, NO 3 , SO 4 Dissolved CO 2 ,TDS, Alkalinity , pH, Specific conductance , Tem- perature , Oxidaon-reducon potenal , Sulfur hexaflouride , Hydrogen sulfide , Acetaldehyde CO2 Stream O 2 , CO 2 , H 2 S, As, S, Se, Hg, Water vapor Monitored Fluid Chemical Parameters Well Tesng and Monitoring Plan B—Area of Review and Correcve Acon Modeling As per Class VI rules, the Area of Review is to be derived from modeling results. Sensivity studies indicated that due to the buoyant nature of the injectate, the plume and the pressure fronts are highly influenced by the scale of the modeling and the resoluon of the petrophysical properes derived from ge- ophysical logs, laboratory measurements, and field tests. Ulizing current pracces of construcng a layered-cake model can provide misleading results. Consequently, a high level of effort was expended to characterize the injecon and confining zones at high resoluon, and develop methodologies to extrap- olate the hydrogeologic properes throughout the model do- main. Hydrogeologic Characterizaon of the Injecon and Confining Zones Two 5,000+ feet wells were drilled into basement to derive an extensive suite of geophysical logs, obtain core and swab samples, and conduct hy- draulic tests. The geochemistry data, including ion composion, molar raos, biogeochemistry, and isotopic characterizaon were used to esmate the competence of the caprock and hydraulic straficaon within the injecon zone. The biomass concentraons and microbial diversity/counts confirmed the existence of a highly strafied Arbuckle reservoir. X-Ray Diffracon and Spectral Gamma Ray Analyses (specifically the Rhomma- Umma analysis) were ulized for mineralogical characterizaon of the injecon and confining zone, which was necessary to develop the reacon kinecs for conducng geochemical simulaons in order to predict the sequestraon potenal in the mineralogical phase and for esmang the change in formaon properes such as permeability and porosity due to precipitaon of minerals. Helical computerized tomography scans were used to inspect the texture of the rocks and to inspect for the presence of very minute fractures. Nuclear Magnetic Resonance (NMR) and sonic logs were used to estimate the matrix and vuggy porosities. The T2 distribution data from the NMR logs was used to estimate the pore throat radius (as a function of capillary pressure) in order to calculate the entry pressure of the caprock. The Flow Zone Interval and residual saturaon informaon was used to develop a new technique for esmang hydraulic conducvity profile, which compared favorably with core based esmates of this property. The characterized data was the combined with 3D multi-component seismic volume in a geocellular model which was used to develop a multiphase flow and transport simulation model for predicting subsurface fluid pressures and the extent of CO2 plume migration. Seismic Invesgaons The discovery of an 8,000 feet long fault immediately west of the proposed injecon well complicated the perming process with EPA. Extensive (and unplanned) research was conducted to establish the regional stress field ulizing drilling induced fractures and step rate test data, which was combined with analycal techniques to establish the fault Slip Tendencies. Several publicaons were pre- pared over a period of 18 months to sasfactorily demonstrate to EPA that the injecon would not pose a seismic risk. Components of Class VI Permit The Class VI permit consists of 9 plans, referred to as Aachments. Aachments related to well and infrastructure construcon, and operaons are relavely easy to prepare. Plans re- lated to AoR, Tesng and Monitoring, Post-injecon Site Care, Emergency and Remedial Re- sponse, and Financial Responsibility can be challenging and potenally expense to prepare. Plan E—Post-injecon Site Care and Closure Plan In order to reduce the default post-injecon monitoring period of 50 years, KGS conducted sensivity studies with various formaon parameters (temperature, dispersivity, etc) and constuve relaons to demonstrate stabilizaon of the plume and injecon pressure in a shorter me frame. Laboratory based experiments were also conducted in order to establish capillary pressure and relavely permeability relaonships of the for- maon material. Analycal approaches were developed and applied to populate the derived properes within the model domain. Field based criteria for plume and pressure stabilizaon were developed and incorporated in the permit as condions to allow site closure. 2D and 3D seismic surveys are to be conducted for verificaon of the plume extent prior to closure. Plan H - Financial Responsibility EPA assessed the financial obligaon of the Wellington project at $70.01 million (M), which translates to an esmated annual cost of approximately $2M (3% of face value) as premium for an insurance policy or deprived interest to finance a trust fund. Further compounding maers was the (default) 50 year post-injecon monitoring period, resulng in prohibive costs. The challenge therefore was to reduce the financial obligaon, most of which was associated with protecng any USDW at the site. To demonstrate the absence of any USDW at the site, KGS constructed 3 new wells, conduct region wide water quality sampling/tesng and geologic research. The water levels in the new wells were monitored for a period of 6 months, and the data was ulized to esmated the formaon hydraulic properes, which revealed aquiclude like condions in any potenal USDW. The TDS in the new wells were in excess of 40,000 mg/l. The regional water quality informaon collected for the study was carefully analyzed in order to develop a verifiable conceptualizaon of the hydrogeology, and to delineate the boundaries of brackish water with TDS greater than 10,000 mg/l. The finding were documented in 5 separate report published for the EPA , which successfully demonstrated the absence of a USDW at the site, resulng in lowering of the financial obligaon to $6.1M from $70.01M. Approximately 12 human-months were to expended to achieve the results. Plan C—Tesng and Monitoring The goals of the Wellington Tesng and Monitoring Plan are to ensure safe injecon, track the plume and pressure fronts, and to provide early warning of deterio- rang condions. The plan is closely linked with the Wellington Plan for Safe and Efficient Injecon which is to be executed if predefined safety thresholds are to be exceeded. A unique feature of the plan is to monitor for Sulfur Hexafluoride (SF 6 ) which is to be injected as a tracer in order to disnguish the CO2 source on account of CO2 based Enhanced Oil Recovery acvies in the overlying Mississippian reservoir at the site. The pressures in the Mississippian reservoir are also to monitored in order to assist in induced seismicity evaluaons. A 169-page Quality Assurance protocol was developed for the project to ensure validity of the monitored data and to derive stascally defensible conclusions. Plan F—Emergency and Remedial Response In order to ensure safety and to migate the impacts of catastrophic events, the Wellington Plan for Safe and Efficient Injecon was developed. This first-of-a-kind plan is likely to serve as a template for future CO sequestraon projects, and consists of 4 sub-plans: Monitoring Based Rapid Response Plan, Wellington Seismic Ac- on Plan, Emergency Remedial Response Plan, and the Injecon Control Plan.

Transcript of Tiraz irdie, Jennifer Hollenbach, Lynn Watney, Eugene ......Tiraz irdie, Jennifer Hollenbach, Lynn...

Page 1: Tiraz irdie, Jennifer Hollenbach, Lynn Watney, Eugene ......Tiraz irdie, Jennifer Hollenbach, Lynn Watney, Eugene Holubnyak, Mina Fazelalavi, Tandis idgoli, Dana Wreath Introduction

US EPA Class VI CO2 Injection Permit — Requirements and Lessons Learnt from the Wellington, Kansas, Project

Tiraz Birdie, Jennifer Hollenbach, Lynn Watney, Eugene Holubnyak, Mina Fazelalavi, Tandis Bidgoli, Dana Wreath

Introduction

The Wellington demonstration project involves injecting 26 KTons of CO2 in the cam-

bro-ordovician Arbuckle aqui-

fer in central Kansas. A US EPA

Class VI injection permit is re-

quired for CO2 sequestration

in saline aquifers. The primary

objectives of the EPA are to

protect Underground Sources

of Drinking Water (USDW; TDS

< 10000 mg/l), and to prevent

any injected CO2 from escap-

ing into the atmosphere with-

in the Area of Review (AoR).

The AoR is defined as the larg-

er of the maximum extent of

a) the CO2 plume, or b) the pressure boundary within which brines from the injec-

tion zone can migrate into overlying USDW via abandoned wells, leakage in the in-

jection well, or breach of the confining zone.

Plans Key Challenges

A- Operating Require-

ments

No key challenges

B– Area of Review and Cor-

rective Action

High resolution characterization of injection and confining zones,

addressing uncertainties in formation petrophysical properties,

and addressing seismic risk

C—Testing and Monitoring Region wide (indirect) monitoring of plume and pressure front

D—Well Plugging No key challenges

E—Post-Injection Site Care Reducing default monitoring period of 50 years

F— Emergency and Reme-

dial Response

Develop project specific plans to ensure safe and efficient injec-

tion, and design/installation of ground-motion sensing equipment

G—Construction Details No key challenges

H— Financial Assurance Reducing default obligation of approximately $70 Million

I— Stimulation Program No key challenges

Permit Timeline

The Wellington permit submittal was the first application for a newly constructed CO2 sequestration well since

promulgation of the Class VI Rule in 2011. During the application process, it was realized that were many tech-

nical issues for which guidance and precedence was lacking. For example, the Class Rule did not have any for-

mal regulations/guidelines for addressing the subject of induced seismicity. As shown in the permit timeline

below, the Wellington team had to expend time and budget on many activities that were unanticipated at com-

mencement of the project. Several of the first-of-a-kind studies conducted in pursuit of the permit and the ac-

companying reports are expected to serve as a guide and template for future CO2 sequestration projects.

Class VI Based Allowable Increase in Pore Pressure

Class VI pressure limitations may restrict commercial scale CO2 sequestration

to western half of the state

Project Task EPA Cost

Corrective Action $0

Well Plugging $0.22M

Post-Injection Site Care $0.29M

Site Closure $1.01M

Emergency Response $68.48M

Total $70.01M

Emergency Scenarios

Well Integrity Failure

Equipment Failure

Water Quality Changes

Migration of CO2 out of Injection Zone

Release of CO2 to Surface

Natural Disaster

Induced Seismicity Event

Wellington Operating Plan

For

Safe and Efficient Injection

Monitoring Based Rapid Response Plan

Wellington Seismic Action Plan

Injection Control Plan

Emergency Remedial Response Plan

A network of 15 seismometers was installed to provide early

warning of deteriorating conditions. Corrective actions are to

be implemented at pre-set thresholds as specified in the Wel-

lington Seismic Action Plan. Collectively, these measures will

ensure safe injection at the site. The seismometers have been

monitoring ground motion since 2015 and assist in seismic re-

search.

Indirect Direct

Plume 2D and 3D Seismic Surveys,

Continuous Active Source, Crosswell Seismic

U-Tube

Pressure Downhole Pressure

& temperature

Passive Seismic, InSAR and cGPS

Injection Zone monitoring

Well Integrity Temperature log, annulus pressure, pressure fall-

off, corrosion coupon

Wellhead Injection rate and volume (flow meter), pressure,

temperature

Annulus Annulur pressure, fluid volume

Arbuckle,

Mississippi-

an, and Wel-

lington For-

mation

Cations: Al, Ba, Mn, As, Cd, Cr, Cu, Pb, Sb Se, and Tl , Ca, Fe, K,

Mg, Na, Si

Anions: Br, Cl, F, NO3, SO4

Dissolved CO2 ,TDS, Alkalinity , pH, Specific conductance , Tem-

perature , Oxidation-reduction potential , Sulfur hexaflouride ,

Hydrogen sulfide , Acetaldehyde

CO2 Stream O2, CO2, H2S, As, S, Se, Hg, Water vapor

Monitored Fluid Chemical Parameters

Well Testing and Monitoring

Plan B—Area of Review and Corrective Action

Modeling

As per Class VI rules, the Area of Review is to be derived from

modeling results. Sensitivity studies indicated that due to the

buoyant nature of the injectate, the plume and the pressure

fronts are highly influenced by the scale of the modeling and

the resolution of the petrophysical properties derived from ge-

ophysical logs, laboratory measurements, and field tests.

Utilizing current practices of constructing a layered-cake model

can provide misleading results. Consequently, a high level of

effort was expended to characterize the injection and confining

zones at high resolution, and develop methodologies to extrap-

olate the hydrogeologic properties throughout the model do-

main.

Hydrogeologic Characterization of the Injection and Confining Zones

Two 5,000+ feet wells were drilled into basement to derive an extensive suite of geophysical logs, obtain core and swab samples, and conduct hy-

draulic tests. The geochemistry data, including ion composition, molar ratios, biogeochemistry, and isotopic characterization were used to estimate

the competence of the caprock and hydraulic stratification within the injection zone. The biomass concentrations and microbial diversity/counts

confirmed the existence of a highly stratified Arbuckle reservoir. X-Ray Diffraction and Spectral Gamma Ray Analyses (specifically the Rhomma-

Umma analysis) were utilized for mineralogical characterization of the injection and confining zone, which was necessary to develop the reaction

kinetics for conducting geochemical simulations in order to predict the sequestration potential in the mineralogical phase and for estimating the

change in formation properties such as permeability and porosity due to precipitation of minerals. Helical computerized tomography scans were

used to inspect the texture of the rocks and to inspect for the presence of very minute fractures.

Nuclear Magnetic Resonance (NMR) and sonic logs were used to estimate the matrix and vuggy porosities. The T2 distribution data from the NMR

logs was used to estimate the pore throat radius (as a function of capillary pressure) in order to calculate the entry pressure of the caprock. The

Flow Zone Interval and residual saturation information was used to develop a new technique for estimating hydraulic conductivity profile, which

compared favorably with core based estimates of this property.

The characterized data was the combined with 3D multi-component seismic volume in a geocellular model which was used to develop a multiphase

flow and transport simulation model for predicting subsurface fluid pressures and the extent of CO2 plume migration.

Seismic Investigations

The discovery of an 8,000 feet long fault

immediately west of the proposed injection well

complicated the permitting process with EPA.

Extensive (and unplanned) research was conducted to establish

the regional stress field utilizing drilling induced fractures and step

rate test data, which was combined with analytical techniques to

establish the fault Slip Tendencies. Several publications were pre-

pared over a period of 18 months to satisfactorily demonstrate to

EPA that the injection would not pose a seismic risk.

Components of Class VI Permit

The Class VI permit consists of 9 plans, referred to as Attachments. Attachments related to

well and infrastructure construction, and operations are relatively easy to prepare. Plans re-

lated to AoR, Testing and Monitoring, Post-injection Site Care, Emergency and Remedial Re-

sponse, and Financial Responsibility can be challenging and potentially expense to prepare.

Plan E—Post-injection Site Care and Closure Plan

In order to reduce the default post-injection monitoring period of 50 years, KGS conducted sensitivity studies

with various formation parameters (temperature, dispersivity, etc) and constitutive relations to demonstrate

stabilization of the plume and injection pressure in a shorter time frame. Laboratory based experiments were

also conducted in order to establish capillary pressure and relatively permeability relationships of the for-

mation material. Analytical approaches were developed and applied to populate the derived properties within

the model domain. Field based criteria for plume and pressure stabilization were developed and incorporated

in the permit as conditions to allow site closure. 2D and 3D seismic surveys are to be conducted for verification

of the plume extent prior to closure.

Plan H - Financial Responsibility

EPA assessed the financial obligation of the Wellington project at $70.01 million (M), which translates to an estimated annual cost of

approximately $2M (3% of face value) as premium for an insurance policy or deprived interest to finance a trust fund. Further compounding

matters was the (default) 50 year post-injection monitoring period, resulting in prohibitive costs. The challenge therefore was to reduce the

financial obligation, most of which was associated with protecting any USDW at the site.

To demonstrate the absence of any USDW at the site, KGS constructed 3 new wells, conduct region wide

water quality sampling/testing and geologic research. The water levels in the new wells were monitored

for a period of 6 months, and the data was utilized to estimated the formation hydraulic properties, which

revealed aquiclude like conditions in any potential USDW. The TDS in the new wells were in excess of

40,000 mg/l.

The regional water quality information collected for the study was carefully analyzed in order to develop a verifiable conceptualization

of the hydrogeology, and to delineate the boundaries of brackish water with TDS greater than 10,000 mg/l. The finding were documented in

5 separate report published for the EPA , which successfully demonstrated the absence of a USDW at the site, resulting in lowering of the

financial obligation to $6.1M from $70.01M. Approximately 12 human-months were to expended to achieve the results.

Plan C—Testing and Monitoring

The goals of the Wellington Testing and Monitoring Plan are to ensure safe injection, track the plume and pressure fronts, and to provide early warning of deterio-

rating conditions. The plan is closely linked with the Wellington Plan for Safe and Efficient Injection which is to be executed if predefined safety thresholds are to be

exceeded. A unique feature of the plan is to monitor for Sulfur Hexafluoride (SF6) which is to be injected as a tracer in order to distinguish the CO2 source on account

of CO2 based Enhanced Oil Recovery activities in the overlying Mississippian reservoir at the site. The pressures in the Mississippian reservoir are also to monitored in

order to assist in induced seismicity evaluations. A 169-page Quality Assurance protocol was developed for the project to ensure validity of the monitored data and to

derive statistically defensible conclusions.

Plan F—Emergency and Remedial Response

In order to ensure safety and to mitigate the impacts of catastrophic events, the Wellington Plan for Safe and Efficient Injection was developed. This first-of-a-kind

plan is likely to serve as a template for future CO sequestration projects, and consists of 4 sub-plans: Monitoring Based Rapid Response Plan, Wellington Seismic Ac-

tion Plan, Emergency Remedial Response Plan, and the Injection Control Plan.