Timer Details
-
Upload
dheeraj-yadav -
Category
Documents
-
view
233 -
download
4
description
Transcript of Timer Details
T302
N302
T304
N304
T305
T307
T308
N308
T309
T312
D2000 3 D2000 3 D30 D30 D40 1 5 6D2000 3 D2000 3 D30 D30 D40 1 5 6D2000 3 D2000 3 D30 D30 D40 1 5 6
UCONNMODETIMER
N312
T313
N313
T314
T315
N315
T316
T381
N381
T323
D1 10 D100 D0 D0 D1 D30 D600 D1 INVALIDD1 10 D100 D0 D0 D1 D30 D600 D1 INVALIDD1 10 D100 D0 D0 D1 D30 D600 D1 INVALID
MML_RNCID
CHANNELRETRYTIMERLEN
CHANNELRETRYHOTIMERLEN
RABMODIFYTIMERLEN
ZERORATEUPFAILTORELTIMERLEN
MML_RNCID
T300
N300
1 5 2 5 180 1 D2000 32 5 2 5 180 2 D2000 33 5 2 5 180 3 D2000 3
UIDLEMODETIMERUCOIFTIMER
T312
N312
MML_RNCID
CNID
CNOPINDEX
RSTRSNDNUM
RAFCTMR
RATCTMR
STATEINDTMR
6 D1 1 1 0 2 30000 120000 200006 D1 2 3 0 2 30000 120000 200006 D1 3 1 0 2 30000 120000 20000
2 0 2 30000 120000 200001 0 2 30000 120000 200003 0 2 30000 120000 20000
UIUTIMERANDNUM
IGORTMR
INTRTMR
MML_RNCID
PSINACTTMRFORCON
PROTECTTMRFORCON
PSINACTTMRFORSTR
PROTECTTMRFORSTR
PSINACTTMRFORINT
PROTECTTMRFORINT
20000 60000 1 20 20 20 20 20 2020000 60000 1 20 20 20 20 20 2020000 60000 2 20 20 20 20 20 2020000 60000 220000 60000 320000 60000 3
UPSINACTTIMER
PSINACTTMRFORBAC
PROTECTTMRFORBAC
PSINACTTMRFORIMSSIG
PROTECTTMRFORIMSSIG
PSINACTTMRFORPREFSTDRM
PSINACTTMRFORFSTDRMDCH
PSINACTTMRFORFSTDRMFACH
MML_RNCID
RRCUERSPTMR
20 20 20 20 360 4 10 1 500020 20 20 20 360 4 10 2 500020 20 20 20 360 4 10 3 5000
USTATETIMER
RRCIURELCMDTMR
RRCRELRETRANTMR
RRCPAINGTYPE1TMR
RRCINITDTTMR
RRCRLCACKCMPTMR
RBSETUPRSPTMR
UECAPENQRSPTMR
RBRECFGRSPTMR
RBRELRSPTMR
RLSETUPRSPTMR
5000 350 5000 5000 1000 5000 5000 5000 5000 50005000 350 5000 5000 1000 5000 5000 5000 5000 50005000 350 5000 5000 1000 5000 5000 5000 5000 5000
USTATETIMER
RLRECFGREADYTMR
RLRELRSPTMR
RLRSTRTMR
DRLAAL2ESTINDTMR
DRLRECFGCMITTMR
HOCELLUPDATERSPTMR
HORELOCREQTMR
HOPAGINGRSPTMR
HOASUTMR
HOWTTRCHRECFGRSPTMR
5000 5000 11000 5000 5000 5000 5000 5000 5000 50005000 5000 11000 5000 5000 5000 5000 5000 5000 50005000 5000 11000 5000 5000 5000 5000 5000 5000 5000
HOPHYCHRECFGTMR
RELOCCMDTMR
RELOCIURELCMDTMR
RELOCDATAFWDTMR
RELOCANOTHERTMR
RELOCCOMMITTMR
RELOCMOBILCONFTMR
RELOCPHYCHRECFGTMR
RELOCUTRANHOCMPTMR
RELOCFAILIURELCMDTMR
5000 10000 45000 20000 5000 15000 5000 5000 10000 50005000 10000 45000 20000 5000 15000 5000 5000 10000 50005000 10000 45000 20000 5000 15000 5000 5000 10000 5000
SYSHOPSRESUMETMR
RRCSECRTMODECMPTMR
UECNTCHECKRSPTMR
CMCHRSRCRSPTMR
IUCSRELNORABTMR
IUPSRELNORABTMR
RRCCONNREJWAITTMR
MML_RNCID
CELLRESELECTTIMER
10 5000 5000 5000 300 300 4 1 18010 5000 5000 5000 300 300 4 2 18010 5000 5000 5000 300 300 4 3 180
UUESTATETRANSTIMER
BEF2PSTATETRANSTIMER
BED2FSTATETRANSTIMER
BEH2FSTATETRANSTIMER
RTDH2FSTATETRANSTIMER
BEE2FSTATETRANSTIMER
BECPC2FSTATETRANSTIMER
RTCPC2FSTATETRANSTIMER
BED2EFACHSTATETRANSTIMER
BEH2EFACHSTATETRANSTIMER
RTDH2EFACHSTATETRANSTIMER
65535 5 5 180 2 5 180 5 5 18065535 5 5 180 2 5 180 5 5 18065535 5 5 180 2 5 180 5 5 180
UUESTATETRANSTIMER
BECPC2EFACHSTATETRANSTIMER
RTCPC2EFACHSTATETRANSTIMER
MML_RNCID
5 180 15 180 25 180 3
TIMERT302N302
T304
N304
T305
T307
T308
N308
T309
T312
N312
T313
N313
T314
T315
N315
T316
T381
N381
T323
Details
Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 3.
Maximum number of retransmissions of UE CAPABILITY INFORMATION. Protocol default value is 3
T307 is started after T305 has expired and the UE detects "out of service area". It is stopped after the UE detects "in service area". The UE will enter idle mode upon expiry.
Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 1
Maximum number of successive "in sync" indications received from L1.
Maximum number of successive "out of sync" indications received from L1.
Maximum number of resend times of message "RRC CONNECTION SETUP" or "CELL UPDATE CONFIRM". default value is 1.
T302 is started after the UE transmits the CELL UPDATE/URA UPDATE message and stopped after the UE receives the CELL UPDATE CONFIRM/URA UPDATE CONFIRM message. CELL UPDATE/URA UPDATE will be resent upon the expiry of the timer if V302 less than or equal to N302; otherwise, the UE will enter idle mode.
T304 is started after the UE sends the UE CAPABILITY INFORMATION message and stopped after the UE receives the UE CAPABILITY INFORMATION CONFIRM message. UE CAPABILITY INFORMATION will be resent upon the expiry of the timer if V304 less than or equal N304; otherwise the cell update procedure will be initiated. Protocol default value is 2000.
T305 is started after the UE receives CELL UPDATE CONFIRM/URA UPDATE CONFIRM in CELL_FACH, URA_PCH or CELL_PCH state. It is stopped after the UE enters another state. CELL UPDATE will be transmitted upon the expiry of this timer if T307 is not activated and the UE detects "in service area";
T308 is started after the UE transmits RRC CONNECTION RELEASE COMPLETE. This message will be sent upon the expiry of the Timer if V308 less than or equal to N308, otherwise, the UE will enter idle mode.
T309 is started after the UE is reselected to a cell belonging to another radio access system in connected mode, or the CELL CHANGE ORDER FROM UTRAN message is received. It is stopped after the UE is successfully connected in the new cell. The UE will continue the connection to UTRAN upon expiry. Protocol default value is 5.
T312 is started when UE starts to establish a DCH, and stopped when UE detects consecutive N312 "in sync" indications from L1. It indicates physical channel setup failure upon the expiry of the timer.
T313 is started after the UE detects consecutive N313 "out of sync" indications from L1. T313 is stopped after the UE detects consecutive N315 "in sync" indications from L1.It indicates Radio Link (RL) failure upon expiry.
T314 is started when the criteria for radio link failure are fulfilled and only radio bearers (RBs) associated with T314 exist.T314 is stopped after the Cell Update procedure has been completed. In case of the RL failure when the UE is in CELL_DCH state, If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T314 (or T315), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T314 should be set greater than T302*N302. In case of the expiry of T314, the corresponding service RBs will be removed.
T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer associated with T315 exists.T315 is stopped after the Cell Update procedure has been completed. In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE is sent. If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T315 should be set greater than T302*N302. In case of the expiry of T315, the corresponding service RBs will be removed.
T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer associated with T315 exists.T315 is stopped after the Cell Update procedure has been completed.In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE is sent. If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T315 should be set greater than T302*N302. In case of the expiry of T315, the corresponding service RBs will be removed.
T316 is started after the UE detects "out of service area" in URA_PCH or CELL_PCH state.T316 is stopped after the UE detects "in service area".The cell update procedure will be initiated upon the expiry of the timer if "in service area" is detected; otherwise, T317 will be started. The UE will enter CELL_FACH state and initiate cell update procedure when the UE detects "in service area". Protocol default value is 30.
T381 is started after the RNC send message "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM"). If T381 expire and RNC does not receive "RRC CONNECTION SETUP COMPLETE"(or the response of "CELL UPDATE CONFIRM") and V381 is smaller than N381, RNC resend "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM") and restart timer T381 and increase V381. If RNC receive "RRC CONNECTION SETUP COMPLETE"(or the response of "CELL UPDATE CONFIRM"), T381 will be stopped. Default value is 600ms.
If the UE checks that no PS/CS data is transmitted, the UE will send the SIGNALLING CONNECTION RELEASE INDICATION message to the RNC, informing the RNC to terminate the PS data session. Meanwhile, the UE starts T323. The UE shall be inhibited from sending the SIGNALLING CONNECTION RELEASE INDICATION message with the IE "Signalling Connection Release Indication Cause" set to "UE Requested PS Data session end" whilst timer T323 is running.
Default Value RecommendedD2000
3
D2000
3
D30
D30
D40
1
5
6
D1
10
D100
D0
D0
D1
D30
D600
D1
INVALID