A.C.S.U. ICC Management Meeting 23 January 2012 ICC Management Meeting 23 January 2012.
TIME Meeting, M. Minty, January 18, 2011
description
Transcript of TIME Meeting, M. Minty, January 18, 2011
TIME Meeting, M. Minty, January 18, 2011
Instrumentation SystemsRHIC RUN-11 Startup
ramp development with simultaneous orbit, tune, and coupling feedback new timing setup procedure (defer) new global orbit feedback (defer)
Ramp Development, RHIC RUN-11
leading cause of failure:poor orbit control
post-shutdown commissioning:
RUN-9 : 13 ramps until blue/yellow at 250 GeV RUN-11: 4 ramps until blue/yellow at 250 GeV
post mortem, RUN-9:
Ramp Development, RHIC RUN-11tune / coupling feedback - Y. Luo, A. Marusic, K. Mernick, M. Minty, M. Wilinski, + operations
RUN-8 RUN-9 RUN-11
TUNE
SCO
UPLIN
G
fill 9922 fill 10057 fill 14822
history: proof-of-principle in RUN-6 (P. Cameron, Y. Luo, R. Jones et al) considerable modifications just before and during RUN-9 operational in RUN-10
RUN-9 RUN-11 (blue)
Ramp Development, RHIC RUN-11orbit feedback – A. Marusic, M. Minty, V. Ptitsyn, G. Robert-Demolaize
ORBITS measured just after attaining first ramp to 250 GeV:
fill 10057 fill 14822
horiz
onta
lve
rtica
l
history: proof-of-principle in RUN-10 BPM polarity reversal, early RUN-10
RUN-11 (yellow)
fill 14822