A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-1
T i l t - W a s h D o u b l e - H u n g W i n d o w s
• 20/10 year limited warranty, fully transferable, non-prorated
• Low-E or dual pane insulating glass
• White or sandtone vinyl clad low-maintenance exteriors
• Narrow profiles for larger glass area
• An in-sash balancer to minimize the view of the jamb liner
• Clear pine or optional prefinished white interior
• Innovative sizing format to simplify ordering and installation
Contents
Tilt-Wash Double-Hung Windows
Basic Unit Details - Tilt-Wash Double-Hung Windows for 4-1/2” Wall ............................................... 19-2
Basic Unit Details - Picture, Transom and Circle Top™ Windows with Extension Jambs ...................... 19-3
Basic Unit Details - Tilt-Wash Double-Hung Windows with Drywall Return ......................................... 19-4
Basic Unit Details - Picture, Transom and Circle Top™ Windows with Drywall Return ......................... 19-5
Options / Accessories
Andersen® Grilles ....................................................................................... 19-6
Extension Jambs for Tilt-Wash Double-Hung Windows .....................19-7
Stool Applications ..........................................................................19-7
Extension Jambs for Picture, Transom and Circle Top™ Windows ......19-8
Trim Options and Applications
Plinth Blocks for Circle Top™ Windows ..............................................19-9
Interior Casing for Circle Top™ Windows .........................................19-10
Joining Details for 4-1/2” Wall ........................................................................ 19-11
Joining Details with Drywall Return .................................................................. 19-12
Anchoring Methods ......................................................................................... 19-13
Suggested Product Applications ...................................................................... 19-14
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-2
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical Section
Basic Unit Details
Horizontal SectionThrough Lower Sash
Tilt-Wash Double-Hung Windows for 4-1/2” WallScale 3" = 1'-0" (1:4)
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
4-1/2"(114)
1-5/16"(33)
Optionalinsectscreen
1/4"(6)
1/4"(6)
Clea
r Opg
. Hei
ght
1-13/16"(46)
11/16" (17)
1/2" (13)
11/16" (17)
1/2" (13)3"
(76)
Glas
s He
ight
3"(76)
2-1/8"(54)
Lower sash in full open position
Glas
s He
ight
2-5/8"(67)
1-7/8"(48)
1-7/8" (47)
1-7/8" (47)
Head
Check Rail
Sill
Horizontal SectionThrough Upper Sash
Rough Opening Width1/4"(6)
1/4"(6)
Lowersash
Uppersash
Unit Dimension Width
Glass Width3"
(76)3"
(76)
1/2"(13)
11/16"(17)
1-5/16"(33)
3-3/16"(81)
4-1/2"(114)
1-13/16"(46)
Jamb Jamb
Rough Opening Width
1/4"(6)
1/4"(6)
Lowersash
Uppersash
Unit Dimension Width
Glass Width3"
(76)3"
(76)
1/2"(13)
11/16"(17)
1-5/16"(33)
3-3/16"(81)
4-1/2"(114)
1-13/16"(46)
Jamb Jamb
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-3
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical SectionPicture or Transom
Basic Unit Details
Horizontal SectionPicture, Transom
Picture, Transom and Circle Top™ Windows with Extension JambsScale 3" = 1'-0" (1:4)
Horizontal SectionCircle Top™ Unit
Vertical SectionCircle Top™ Unit
3-3/16" (81)
4-1/2" (114)
1-5/16" (33)
Rough Opening Width
Unit Dimension Width
Glass Width 3" (76)
3" (76)
11/16"(17)
3/8"(10)
1/4"(6)
1/4"(6)
1-7/8"(47)
Optional Andersen®extension jamb
Jamb Jamb
Optional Andersen®extension jamb
4-1/2" (114)
1-5/16"(33)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Glas
s He
ight
3-3/16"(81)
1-5/16"(33)
3"(76)
1/4"(6)
11/16" (17)
3/8" (10)
1-15/16" (49)
11/16" (17)
3/8" (10)
1-15/16" (49)
3"(76)
1/4"(6)
Head
Sill
3-3/16" (81)
4-1/2" (114)
1-5/16" (33)
Rough Opening Width
Unit Dimension Width
Glass Width 3" (76)
3" (76)
11/16"(17)
3/8"(10)
1-15/16"(49)
Optional Andersen®extension jamb
Jamb Jamb
1/4"(6)
1/4"(6)
Optional Andersen®extension jamb
4-1/2" (114)
1-5/16"(33)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Glas
s He
ight
3-3/16"(81)
1-5/16"(33)
3"(76)
11/16" (17)3/8" (10)
11/16" (17)
Head
Sill
3/8" (10)
3"(76)
1-7/8" (47)
1-7/8" (47)
1/4"(6)
1/4"(6)
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-4
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical Section
Basic Unit DetailsTilt-Wash Double-Hung Windows with Dr ywall ReturnScale 3" = 1'-0" (1:4)
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Drywall return
1-5/16"(33)
Optionalinsectscreen
1/4"(6)
1/4"(6)
Clea
r Opg
. Hei
ght
1-13/16"(46)
3"(76)
Glas
s He
ight
3"(76)
2-1/8"(54)
Lower sash in full open position
Glas
s He
ight
3-1/16"(78)
1-7/8" (47)
1-7/8" (47)
1-1/16" (27)
1-1/16" (27)
Head
Check Rail
Sill
Horizontal SectionThrough Lower Sash
Horizontal SectionThrough Upper Sash
Rough Opening Width
1/4"(6)
1/4"(6)
Lowersash
Uppersash
Unit Dimension Width
Glass Width3"
(76)3"
(76)
1-5/16"(33)
3-1/16"(78)
1-7/8"(47)
1-1/16"(27)
Drywallreturn
Jamb Jamb
Rough Opening Width
1/4"(6)
1/4"(6)
Lowersash
Uppersash
Unit Dimension Width
Glass Width3"
(76)3"
(76)
1-5/16"(33)
3-1/16"(78)
1-7/8"(47)
1-1/16"(27)
Drywallreturn
Jamb Jamb
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical SectionPicture or Transom
Basic Unit Details
Horizontal SectionPicture, Transom
Picture, Transom and Circle Top™ Windows with Dr ywall ReturnScale 3" = 1'-0" (1:4)
Horizontal SectionCircle Top™ Unit
Vertical SectionCircle Top™ Unit
1-5/16"(33)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Glas
s He
ight
3-1/16"(78)
3"(76)
1/4"(6)
3"(76)
1/4"(6)
Drywall return
1-1/16" (27)
1-7/8" (47)
1-1/16" (27)
1-7/8" (47)
Head
Sill
1-5/16" (33)
Rough Opening Width
Unit Dimension Width
Glass Width 3" (76)
3" (76)
3-1/16"(78)
1-7/8"(47)
1-1/16"(27)
Drywall return
Jamb Jamb
1/4"(6)
1/4"(6)
Drywall return
1-1/16" (27)
1-1/16" (27)
1-5/16"(33)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Glas
s He
ight
3"(76)
Head
Sill
3"(76)
1-7/8" (47)
1-7/8" (47)
3-1/16"(78)
1/4"(6)
1/4"(6)
3-1/16"(78)
1-5/16" (33)
Rough Opening Width
Unit Dimension Width
Glass Width 3" (76)
3" (76)
1/4"(6)
1/4"(6)
1-7/8"(47)
1-1/16"(27)
Drywall return
Jamb Jamb
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-6
T i l t - W a s h D o u b l e - H u n g W i n d o w s
3/8"
3/4"
1/2"
1"
7/16" 7/16" 7/16"
7/8"3/4" 1-1/8"
200 Series Grille Options
Removable Interior Andersen® Finelight™ Grilles-Between-the-Glass
Removable Interior Wood Grille Profiles (chamfer profile).
Grille Profiles Scale = Full
Andersen® Finelight™ Grilles-Between-the-Glass
Standard Grille Options / AccessoriesContact an Andersen Representative for project specific grille options.
Window Profile Patio Door Profile
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-7
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Options / AccessoriesStool Applications (by others)Scale 3" = 1'-0" (1:4)
Horizontal Section
Options / AccessoriesExtension Jambs for T ilt-Wash Double-Hung WindowsScale 3" = 1'-0" (1:4)
Sill
Stool(by others)
Vertical SectionPicture, Transom or Circle Top™ Units
Extension jambs available for 5-1/4” (133), 6-9/16” (167) or 7-1/8” (181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification.
Vertical SectionT ilt-Wash Double-Hung
Sill
Stool(by others)
4-1/
2" (1
14)
Face
: 11/
16"
(17)
Face
: 2"
(51)
Face
: 2-9
/16"
(65)
4-1/2"Wall
5-1/4"Wall
9/16"(14)
6-9/16"Wall
7-1/8"Wall Fa
ce:
1-5/
16"
(33)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)
Jamb
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-8
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Extension jambs available for 4-1/2” (116), 5-1/4” (133), 6-9/16” (167) or 7-1/8” (181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification.
Vertical SectionPicture/Transom Units
Vertical SectionCircle Top™ Units
Options / AccessoriesExtension Jambs for Picture, Transom and Circle Top™ WindowsScale 3" = 1'-0" (1:4)
Face: 2" (51) 5-1/4" Wall
Face: 3-5/16" (84) 6-9/16" Wall
Face: 3-7/8" (98) 7-1/8" Wall
11/16" (17)
1/8" (3)
Face: 1-5/16" (33) 4-1/2" Wall
4-1/2" (114)
5-1/4" (133)
6-9/16" (167)
7-1/8" (181)
Picture/Transom – Sill
Picture/Transom – Head
4-1/2" (114)
5-1/4" (133)
6-9/16" (167)
7-1/8" (181)
Optional Andersen®arch casing
Circle Top – Head
Face: 2" (51) 5-1/4" Wall
Face: 3-5/16" (84) 6-9/16" Wall
Face: 3-7/8" (98) 7-1/8" Wall
11/16" (17)
1/8" (3)
Face: 1-5/16" (33) 4-1/2" Wall
Circle Top – Sill
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-9
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Trim Options and ApplicationsPlinth Blocks for Circle Top™ WindowsScale: HalfAvailable in maple, oak and prefinished white.
Optional Andersen®
interior arch casing(Colonial or Ranch styles)
Optional Andersen® transom casing
2-1/4" Colonial StyleAlso available in prefinished whitewith prefinishedplinth block applied.
Optional Andersen® plinth blocks
Interior trim by others
For use with 2-1/4" or 2-1/2" (57mm or 64mm) casing.
2-7/8" (73mm)
1-1/8" R
2-7/8" (73mm)7/8" (22mm)
For use with 3-1/2" (89mm) casing.
3-7/8" (98mm) 1-1/2" R
3-7/8" (98mm)
7/8" (22mm)
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-10
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Circle Top™ Window
5/32" (4mm) typical
Ranch Style - WM 3242-1/4" x 11/16" (57mm x 17mm)
Available in maple or oak.
Ranch Style - WM 3152-1/2" x 11/16" (64mm x 17mm)
Available in maple only.
Colonial Style - WM 3662-1/4" x 11/16" (57mm x 17mm)
Available in maple or oak.Also available prefinished white
with prefinished plinth block attached.
Colonial Style - WM 3512-1/2" x 11/16" (64mm x 17mm)
Available in maple only.
Colonial Style - WM 4443-1/2" x 11/16" (89mm x 17mm)
Available in maple or oak.Optional Andersen®extension jamb
Trim Options and ApplicationsInterior Casing for Circle Top™ WindowsScale: FullAvailable for all cur ved portions of windows.
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-11
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Tilt-Wash Double-Hung, Picture, Transom and Circle Top™ Windows for 4-1/2” wall Scale 3" = 1'-0" (1:4)
Horizontal Section
Joining Details
Horizontal Section
Horizontal Section
Vertical Section Vertical Section
Double-HungJamb
Double-HungJamb
Unit Dim. Unit Dim.
1/2" (13)
Optional Andersen®non-reinforced wood joining material
Optional Andersen®trim strip
1-11/16"(43) Optional Andersen®
casing
1/2" (13)
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
1-11/16" (43)
Optional Andersen® casing
Optional Andersen®non-reinforced woodjoining material
Optional Andersen®extension jamb
OptionalAndersen®trim strip
Double-Hung – Head
Picture/Transom/Circle Top™ Unit – Sill
Double-HungJamb
Picture/TransomJamb
Unit Dim. Unit Dim.
1/2" (13)
Optional Andersen®non-reinforced woodjoining material
1-11/16"(43)
Optional Andersen®extension jamb
Optional Andersen®casing
Optional Andersen®trim strip
Picture/TransomJamb
Picture/TransomJamb
Unit Dim. Unit Dim.
1/2" (13)
Optional Andersen®non-reinforced woodjoining material
1-11/16"(43)
OptionalAndersen®extension jambs
Optional Andersen®casing
Optional Andersen®trim strip
1/2" (13)
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
Optional Andersen® casing
Optional Andersen®extension jamb
OptionalAndersen®trim strip
Optional Andersen®non-reinforced woodjoining material
Picture/Transom – Head
Picture/Transom/Circle Top™ Unit – Sill
1-11/16"(43)
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-12
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Double-HungJamb
Picture/TransomJamb
Unit Dim. Unit Dim.
1/2" (13)
Optional Andersen®non-reinforced woodjoining material
Optional Andersen®casing
1-11/16"(43)
Optional Andersen®trim strip
Double-HungJamb
Double-HungJamb
Unit Dim. Unit Dim.
1/2" (13)
Optional Andersen®non-reinforced woodjoining material
1-11/16"(43)
Optional Andersen®trim strip
Optional Andersen®casing
Tilt-Wash Double-Hung, Picture, Transom and Circle Top™ Windows with Dr ywall Return Scale 3" = 1'-0" (1:4)
Horizontal Section
Joining Details
Horizontal Section
Horizontal Section
Vertical Section Vertical Section
1-11/16" (43)1/2" (13)
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
Double-Hung – Head
Picture/Transom/Circle Top™ Unit – Sill
OptionalAndersen®trim strip
Optional Andersen®non-reinforced wood joining material
Optional Andersen®casing
1/2" (13)
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
1-11/16" (43)
Picture/Transom – Head
Picture/Transom/Circle Top™ Unit – Sill
OptionalAndersen®trim strip
Optional Andersen®non-reinforced wood joining material
Optional Andersen®casing
Picture/TransomJamb
Picture/TransomJamb
Unit Dim. Unit Dim.
1/2" (13)
Optional Andersen®non-reinforced woodjoining material
Optional Andersen®casing
1-11/16"(43)
Optional Andersen®trim strip
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-13
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Anchoring MethodsJamb ClipScale 3" = 1'-0" (1:4)
Score markings for bending
3/16"(5)
1-1/2"(38)
3"(76)
APPLICATION:
• First secure jamb clip to back side of window unit jamb(s)
• Apply 1' from corners of head jamb, sill and side jambs
• Space jamb clips evenly (maximum distance apart 32" on center)
• Jamb clip lateral design load capacity: maximum 200 lb.
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Double-hung window is secured in the opening by removing the weather-strip and drilling through the side jamb into the masonry.
Jamb clip
Double-hung window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clips to secure unit fit in opening. Installation flange can be cut as required to accommodate the jamb clips.
Threaded fastener(furnished byothers)
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 519-14
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Wall TypesSuggested Product Applications
Scale 1-1/2" = 1'-0" (1:8)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Sill
Jamb
Head
Installationflangeall around
Installationflange all around
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Head
Jamb
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
*1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing.
1/2" (13)*minimum
Removeinstallationflangeat head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
Unit
Dim
.W
i dth
1/4"(6)
Installationflange allaround
Head
Jamb
Sill
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be
fully attained. Written installation instructions which provide guidelines for proper installation are available
for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12,
Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation
is different. Andersen strongly recommends consultation with an Andersen product representative and with
an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product.
Installation of Andersen products, including method of attachment, fastener selection, and code compliance is
the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or
roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the
weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5 19-15
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Suggested Product Applications
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Head
Jamb
Optional Andersen®
auxiliarycasing
Sill
Unit
Dim
ensi
on H
eigh
t
Installationflange at headand jambs
Roug
h Op
enin
g He
ight
Removeinstallationflangeat sill
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Jamb
Head
Sill
Optional Andersen®
auxiliarycasing
Installationflangeall around
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Existing masonry wall
Installationflange all around
Jamb
Head
Sill
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersen®
rigid vinylchannel
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Optional Andersen®
vinyl trim board
Existingframe wall
Installationflangeall around
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be
fully attained. Written installation instructions which provide guidelines for proper installation are available
for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12,
Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation
is different. Andersen strongly recommends consultation with an Andersen product representative and with
an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product.
Installation of Andersen products, including method of attachment, fastener selection, and code compliance is
the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or
roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the
weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.