TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid...

24
Technical Information TI 257F/24/ae Hydrostatic Level Measurement deltapilot S DB 50A, DB 51A, DB 52A deltapilot S DB 50S deltapilot S DB 53A Level sensors with “CONTITE” measuring cell; watertight, condensation-free, stable For food, beverage, water, wastewater, chemicals and pharmaceuticals Application The Deltapilot S product range is designed for continuous level measure- ment of liquids and pastes in the chemical, pharmaceutical, and food/ beverage industries, as well as in water and wastewater treatment. Features and Benefits New “CONTITE” measuring cell: watertight, condensation-free, with long-term stability excellent linearity (better than 0.2% of measuring range), optional 0.1% low temperature coefficient (better than 0.006%/10°F or 0.1%/10K) continuous temperature compensation of fill fluid ensures accurate measurement under changing process conditions, and reduced downtime after SIP/CIP cleaning procedures Probes in compact, rod or cable versions Separate mounting of housing and electronic insert, NEMA 6 submersible (IP68) at measuring point Simple and easy operation via 4 to 20 mA, HART ® , PROFIBUS-PA, or FOUNDATION Fieldbus DB 50 S DB 53 A DB 52 A DB 51 A The Power of Know How

Transcript of TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid...

Page 1: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

TechnicalInformationTI 257F/24/ae

Hydrostatic Level Measurementdeltapilot S DB 50A, DB 51A, DB 52Adeltapilot S DB 50Sdeltapilot S DB 53A

Level sensors with “CONTITE” measuring cell;watertight, condensation-free, stableFor food, beverage, water, wastewater,chemicals and pharmaceuticals

ApplicationThe Deltapilot S product range isdesigned for continuous level measure-ment of liquids and pastes in thechemical, pharmaceutical, and food/beverage industries, as well as in waterand wastewater treatment.

Features and Benefits• New “CONTITE” measuring cell:

– watertight, condensation-free, withlong-term stability

– excellent linearity (better than 0.2%of measuring range), optional 0.1%

– low temperature coefficient (betterthan 0.006%/10°F or 0.1%/10K)

– continuous temperaturecompensation of fill fluid ensuresaccurate measurement underchanging process conditions,and reduced downtime afterSIP/CIP cleaning procedures

• Probes in compact, rod or cableversions

• Separate mounting of housing andelectronic insert, NEMA 6 submersible(IP68) at measuring point

• Simple and easy operation via4 to 20 mA, HART®, PROFIBUS-PA,or FOUNDATION Fieldbus

DB 50 S

DB 53 A

DB 52 ADB 51 A

The Power of Know How

Page 2: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

Versions Modular Probes for a Perfect Fit• Compact version

– mounted in the tank wall or base• Rod or cable version

– top mounted for simple installationand retrofitting of buried tanks

– requires no extra openings in thebase of the tank

• Remote housing adapter– allows separate mounting of

housing, electronic insert, andremote operation from themeasuring point

– submersible (NEMA 6/IP 68) at themeasuring point.

Optimum Process Fit• Hastelloy C4 diaphragm gives high

mechanical and chemical resistance• Pressure resistant diaphragm:

– overload resistance to 20x nominalpressure, max. 380 psi (25 bar)vacuum to -13 psi (-900 mbar)

• FM approved intrinsically safe

Process Connections for SanitaryApplications• All common flush-mounted process

connections available. Meets 3-Asanitary standards

• Fill fluid recognized as GRAS(Generally Regarded As Safe) byFDA and USDA

• Automatic temperature compensationoutperforms diaphragm seal units

• Sanitary process connections forcleaning without residue (CIP)

• Measuring cell with Hastelloy C4diaphragm as standard, elastomer-free with welded cell seal.

• Housing adapter– recommended for high humidity

and hose-down areas, allowsseparate mounting of housing,electronic insert, and remoteoperation from the measuring point

– submersible (NEMA 6/IP 68) at themeasuring point.

Rugged and Resistant – Ideal forWater and Wastewater Treatment• Electronic inserts with integrated

overvoltage protection againstlightning strikes (optional)

• Stainless steel measuring cell tubeand Hastelloy cell diaphragm allowuse in applications with aggressivemedia.

• Sensor cables up to 665 ft. (200 m)long require no tension relief.

• Resistant to build-up• Direct replacement for bubbler

systems• Optional: Rhodium plated diaphragm

for applications where hydrogenformation can occur (e.g. digestedsludge).

For Pumped Liquids– DB 50A compact version,– DB 51A rod version– DB 52A cable version

Food and Pharmaceuticals- DB 50 Smeets 3-A Sanitary Standards

Water and Wastewater Industries– DB 53A

DB 50 ADeltapilot

compact version

DB 51 ADeltapilot

rod version

DB 52 ADeltapilot

cable version

Deltapilot S DB 50 S with weld spudfor flush mounting. Extended versionsavailable for insulated / jacketed tanks.All process connections for sanitary aregap-free for cleaning without residue.

Deltapilot S DB 53 A

Attachment usingmounting clamp

2

Page 3: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

Program Linearization Curve• Enter a linearization curve for a

vertical cylindrical tank with conicaloutlet– enter a maximum of 11 points,

first point for zero is set at height ofsensor which corresponds toempty calibration

– the last point is set for maximumlevel which corresponds to fullcalibration

Versions (con’t) Linearization of Cylindrical Tankswith Conical Outlets for Display ofVolume– DB 50A, DB 51 A, DB 52 A, DB 53 A, DB 50 S

Measuring PrincipleThe weight of a column of liquid gener-ates a hydrostatic pressure. At constantdensity, the hydrostatic pressure is afunction of the height “h” of the column ofliquid only:

phydrostatic = ρ x g x h

ρ = densityg= gravitational constanth = distance between the surface of the liquid and the center of the process diaphragm

Measuring System

3

3

21

6

5

4

Empty

Full

Measuring CellThe heart of the Deltapilot S is the new“CONTITE” measuring cell; condensa-tion free, watertight, and with excellentlong-term stability. The measuring cell isprotected against water hammer up to20x the nominal pressure (maximum of380 psi (25 bar) by a special mechanicalstop.

Temperature CompensationContinuous temperature compensationof expansion/contraction of oil-fillensures accurate measurement underchanging process conditions. Oneadvantage of temperature compensationis that it greatly reduces the downtimeafter SIP or CIP cleaning procedures.

High Accuracy• Pressure resistant measuring cell

overload resistance to 20x nominalpressure (maximum 380 psi(25 bar), vacuum to -13 psi(-900 mbar))

• Low temperature coefficient (betterthan 0.006%/°F or 0.1%/10K).

Pressure CompensationThe sealed “CONTITE” measuring cell isdesigned to measure gauge pressure.The cell is compensated for atmosphericpressure by means of a capillary whichleads from a Goretex filter in the housingdirectly to the measuring element. The“CONTITE” measuring cell is completelysealed against moisture and condensa-tion for reducing sensor drift andextending the life of the transmitter.

Measuring PointThe measuring point consists of:• A Deltapilot S sensor with a HART®

4 to 20 mA FEB 22 electronic insert• A Deltapilot S sensor with a fully

digital FEB 24 PROFIBUS-PAelectronic insert

• A Deltapilot S sensor with FEB 26for connection to FOUNDATIONFieldbus systems

An electronic insert FEB 22 turns theDeltapilot S into a compact instrumentwhich can be operated locally orremotely using a handheld terminal.

Page 4: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

Operation FEB 22 (HART)The electronic insert (FEB 22) ismounted directly in the probe housing,making the Deltapilot S a compacttransmitter and allows:• Simple local empty and full calibration

with push buttons or• Access to the Endress+Hauser user

matrix

– with the operating module FHB 20,

– via a handheld terminal,

– via the Commubox FXA 191 andPC, e.g. with the Commuwin IIoperating program or PLCand PCS

FEB 24 (PROFIBUS-PA)The FEB 24 electronic insert with thePROFIBUS-PA protocol allows:• Local operation with the FHB 20

operating module, or• Matrix operation with a personal

computer and the Commuwin IIoperating program running underMS Windows.

Matrix OperationThe standard Endress+Hauser matrix isa clear and uniform system which iseasy to use no matter whether theDeltapilot S is calibrated with the pushbuttons and display, with the handheldterminal, or with a personal computer viaCommuwin II software.

4

Electronics SelectionDepending on the application andrequirements for the process, variouselectronic inserts are available to meetthe needs of industry.

2

34

FEB 24PROFIBUS-PAvia segment coupler

FEB 22HART4 to 20 mA

Compact transmitter forlocal operation withHART electronic insertFEB 22optional with FHB 20 display

21

1

Connecting andoperating a compactinstrument using aPLC

3

Connection to a PLCor personal computerusing a bus coupler

Direct connection viaFieldbus interface card H1or via ControlNet or HSE

4

FEB 26FOUNDATIONFieldbus via H1interface card

FEB 22 / 22P (HART®)4 to 20 mA analog signal via 2-wirewith FSK signal superimposeddigital communication signalProtocol:- HART®

- local operation with FHB 20 display- remote operation via DXR 275 handheld terminal- connection and operation using a PLC- Commubox FXA 191 and PC with Commuwin II operating program

FEB 24 / 24PDigital communication signal along2-wiresProtocol:- PROFIBUS-PA- with FHB 20 display at measuring point- via bus coupler connection to PLC or PC, e.g. Commuwin II operating program

FEB 26Digital communication signal along2-wiresProtocol:- FOUNDATION Fieldbus- with FHB 20 display at measuring point- connection via FF H1 interface card- connection via ControlNet- connection via HSE (High Speed Ethernet)

Measuring System(con’t.)

NOTE: “P” versions (22P and 24P)include integrated overvoltageprotection.

Page 5: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

Push button OperationThe following basic functions can becalled up with the four push buttons atthe electronics panel:• Empty and full calibration• Calibration with a partially filled vessel• Parameter lock to protect matrix data

Operation with FHB 20 DisplayThe addition of a display allows theEndress+Hauser operating matrix to beaccessed directly. The following addi-tional functions are available:• Display of measured value• Dry calibration• Linearization• Setting and simulation of analog

output• Selection of technical units, etc.• Input of density correction factor

5

Reset:

OR

Empty calibration:

Full calibration:

Lock parameters:

Unlock parameters:

Four push buttons call upbasic calibration functions

The FHB 20 plug-in displayuses the operating matrix

SMART electronics insertFEB 22

VV

HH

YH

+

V H

V H

- +

- +

Handheld TerminalA handheld terminal allows all functionsof the Deltapilot S to be accessed at anypoint in the 4 to 20 mA signal line usingthe universal DXR 275 HART® communi-cator.

Operation with CommuboxThe Commubox FXA 191 links intrinsi-cally safe SMART transmitters with anHART® protocol to the RS 232 C serialinterface of a personal computer. Thisenables transmitters to be remotelyoperated using the Endress+HauserCommuwin II software.

Connecting handheld terminalor Commubox with PC

HazardousArea

SafeArea

4 to 20 mA

OR

Total resistanceminimum 250 Ω

HARTCommunicatorDXR 275

Handheld terminal can be connectedanywhere along the 4 to 20 mA line.

PC with Commuwin IISoftware

CommuboxFXA 191

PROFIBUS-PAThe PROFIBUS-PA is an open fieldbusstandard for connecting sensors andactuators, which may also be in hazard-ous areas using one bus cable. The two-wire sensors are supplied with powerover the PROFIBUS-PA line and theprocess information of the sensor isdigitally transmitted.

The number of instruments at one bussegment:• up to 10 intrinsically safe applications• up to 32 standard (non-hazardous)

applicationsPROFIBUS-PA is an open bus whichallows any PROFIBUS-PA device to beconnected to the bus segment e.g.valves, actuators, or other measuringdevices.

The FEB 24 electronic insert with the PROFIBUS-PAprotocol allows local operationwtih the FHB 20 operating module or matrix operationwith the Commuwin II software. The operatingprogram runs under MS Windows 3.11 or later.

PC with operatingprogram e.g.Commuwin .II

PLC

Segment coupler(PA/DP converter)

PROFIBUS-DP

Fieldbus withPROFIBUS-PA

Tanks with Deltapilot S

Operation (con’t.)

Page 6: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

6

CO H1 AI AO DI

I/O FC LD

CO H1 AI AO DI

Fieldbus H1

Fieldbus H1

ControlNET or HSE

Connection via Link and Fieldbus interface card H1

Direct connection via Fieldbus interface card H1

Connecting to FOUNDATIONFieldbusFOUNDATION Fieldbus is an openfieldbus standard to enable severalsensors and actuators, including thosein explosion hazardous areas, to beconnected to a bus line. With FOUNDA-TION Fielbus, two-wired looped instru-ments can be supplied by the fieldbuswith power and digital process informa-tion.

The maximum number of transmitters ata bus segment depends on the currentconsumption, the minimum powersupply of the transmitters, and also onthe required bus length (conductorresistance) and output voltage of thepower supply unit. The Deltapilot Sconsumes a maximum of 12 mA perdevice.• Up to 9 instruments for hazardous

applications• Up to 32 instruments for nonhazard-

ous applications

Deltapilot S with FOUNDATION FieldbusCO: ControllerH1: H1 interfaceCN: ControlNETAI: Analog inputAO: Analog outputDI: Digital inputI/O: Input/OutputFC: Frequency converterLD: Link

Operation (con’t.)

Page 7: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

7

Installation Mounting PointCompact versionThe DB 50 A and DB 50 S must alwaysbe installed below the lowest measuringpoint.It should not be mounted in the fillingstream, at the tank outlet or at a place inthe tank where pressure pulses from anagitator can occur.Calibration and function testing can becarried out more easily if the DB 50 A ismounted downstream of a cut-off valve.

Rod and Cable versionsThe cable version should be mounted ata point free from currents and turbu-lence, as lateral movement and contactwith the vessel wall can affect accuracy.The probe can be built into a stilling well(preferrably of plastic) or attached to amounting clamp.The length of the support cable or therod probe depends on the zero point ofthe level. The tip of the probe should beat least 2 inches (5 cm) below the zeropoint.When installed in a domed manhole, theprobe should be mounted on a nozzle toprevent the housing from being floodedby moisture or condensation. In verydamp conditions, it is recommended thata remote housing adapter be used tomount the housing and electronic insertaway from the measuring point.

Process DiaphragmThe process diaphragm is not to behandled or cleaned with hard or pointedobjects. Measurement is unaffected bymaterial build-up, provided the build-upis elastic and can transmit the hydro-static pressure.All Deltapilot S versions with a rod orcable probe extension are supplied witha plastic cover which protects theprocess diaphragm from mechanicaldamage.

Measurement in Pressurized Tanks(Electronic Differential PressureMeasurement)Differential pressure in pressurizedtanks is measured with either a mathmodule (e.g. E+H RMA 422) or PLC andtwo Deltapilot S probes. Probe 1measures total pressure (hydrostatic andhead pressure), Probe 2 detects thehead pressure only.

NOTE: The measuring diaphragm ofProbe 2 must not be flooded as it thendetects an additional hydrostaticpressure.

The ratio of hydrostatic pressure to headpressure should be a maximum of 1 : 6.Ensure that the measuring cell range ofthe two Deltapilot S probes are suitablefor the application (see example below).

Example:Both transmitters should be selected to match themaximum of the total hydrostatic and head pressure.In this case, both transmitters should be selected as60 psig.

Temperature EffectsIn applications where the product canharden when cooled, the Deltapilot Smust also be insulated. Alternatively arod or cable version can be used.

Mounting and operation downstream from acut-off valve.

Do not mount in the outlet of the tank or nearagitators.

In applications where the product can harden,the sensor must be covered by the insulation.

Hydrostaticpressure+ Head

pressure

Headpressure

7.3 psi

15 psi

22.3 psi

0 to 60 psig 0 to 60 psig

Max. height200 in. (5 m)

Max. headpressure

Total pressureat sensor 1

Measuring cellpressure rang e

1

1 2

2

Page 8: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

8

Installation (con’t) Installing the Deltapilot SFor Deltapilot S probes with NPT threadprocess connections, it is recommendedthat the thread is sealed by wrappingwith teflon tape.

NOTE: When tightening, turn the probeby the hexagonal nut only, not by thehousing. Do not screw in too tightly,maximum torque is 15 to 22 ft.lb. (20 to30 Nm).

Rotating the HousingThe housing can be rotated to positionthe cable entry. In order to preventmoisture entering through the conduitentry, the following precautions arerecommended, particularly whenmouting outdoors.The conduit entry should point down-wards when the sensor is mountedlaterally in the tank.The conduit entry should always behorizontal when the sensor is fitted witha protective hood.

Housing Rotation 1

Unscrew housing coverLoosen the Phillips head screwunder the housing 3 to 4 turns

2Rotate housing, maximum 280°

3Securely tighten the Phillips headscrew underneath housing.

Sealing the Probe HousingIt is important that no moisture enters thehousing while mounting the probe,connecting the electronic insert andoperating the measuring system. Thehousing cover and conduit entriesshould always be tight. Always mounthousing so that conduit slopes downand away from the housing, or sealwiring entry with silicone/RTV afterwiring. The O-ring seal in the housingcover and the aluminum cover threadsare lubricated when delivered. If thislubrication has been removed, then itshould be replaced (e.g. silicone orgraphite paste) so that the cover sealstight.NOTE: Do not use mineral-oil basedlubricants, as they may damage theo-ring.

Pressure CompensationA Goretex® filter mounted behind thenameplate or directly on the housing,compensates for pressure in thehousing. During assembly, there is anoverpressure in the probe housingwhich is slowly released through theGoretex® filter. Once the housing coverhas been tightened, wait approximatelyone minute before starting measure-ment. The Goretex® filter also blockswater from entering and allows thehousing to “breathe”, thus preventingcondensation from accumulating.

Remote Housing AdapterThe housing and electronic insert can bemounted remotely from the measuringpoint by using the remote housingadapter. The adapter also enablesproblem-free measurement underespecially difficult conditions (very dampenvironments, wash down areas orareas prone to flooding) or in narrow orinaccessible mounting locations. Theremote adapter is also ideal for mount-ing of the display when using a topmounted rod or cable sensor.Compact instruments with operatingmodule can be easily and simplyoperated and remotely monitored fromthe actual measurement point. Theingress protection at the measuring pointis NEMA 6P submersible (IP 68) withthis arrangement.

Using the remotehousing adapterunder difficultmeasuring conditions

3 to 4 X

1 2 3

max. 280°

Min. bendingradius, 7.9"(200 mm)

NEMA 6Psubmersible(IP 68)

Page 9: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

9

Housings Housing VersionsThe Deltapilot S is available with threeelectronic housing styles: Plastichousing (Type F 10), coated aluminumhousing (Type F 6), or 304 stainlesssteel housing (Type F 8).

NOTE: Type F8 (SS) housing withnonhazardous / standard certificateutilizes a polycarbonate (non-glass)display window.

Instruments specified with the FHB 20display and electronic operating module,a housing cover with transparent lenseis available. All housings have a NEMA4X (IP 66) protection rating.The compact versions shown below arefor side or bottom mounting. The F 8stainless steel housing is designed forsanitary applications.

DB 50 A Dimensions(F 6 and F 10 housing)

DB 50 S Dimensions(F 8 SS housing)

Ø 3.38"(86)

Ø 3.38"(86)

AA

Bw/display

Bw/display

0.98 in.(25)

1-1/2" NPT

F 6 Housing

7.18" (182.5)7.58" (192.5)

1-1/2" NPTConnector

AB

F 10 Housing

7.28" (185)8.01" (203.5)

150 lb ANSIFlange *

AB

F 6 Housing

7.23" (185)7.67" (195)

F 10 Housing

7.38" (187.5)8.11" (206)

* Flanges are available in1-1/2", 2", 3" and 4" sizes

Ø 3.38"(86)

Ø 3.38"(86)

A

Bw/display

Bw/display

A

0.98 in.(25)

1-1/2" NPT

150 lb ANSIFlange *

AB

F 8 Housing

7.08" (180)7.59" (193)

1-1/2" NPTConnector

AB

F 8 Housing

6.97" (177)7.48" (190)

* Flanges are available in1-1/2", 2", 3" and 4" sizes

Page 10: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

10

DB 51 A Rod ProbeDimensions (F 6, F 10and F 8 housing)

DB 52 A Cable ProbeDimensions (F 6, F 10and F 8 housing)

Extension rod material and cell housing is316 L SS or optional Hastelloy C 4. Maximumrod length is 13.1 ft. (4 m). A protective cap(PFA) is provided on the sensor end. Donot remove cap.

Rod probe Deltapilot S is for top mounting only.Ensure there is enough clearance above thevessel for insertion and mounting.

Extension cable material is a stainlesssteel wire cable clad in FEP or PE. Probeis 316 L SS or Hastelloy C4. Maximumlength is 656 ft. (200 m). A protective cap(PFA) is provided on the sensor end. Donot remove cap.

Cable probe is for top mounting only.Ensure there is enough clearance abovethe vessel for insertion and mounting.When using a housing adapter (for remotemounting) the maximum length of thecable is the total length of the supportcable plus the connecting cable to thehousing adapter.

Ø 3.38"(86)

Ø 0.67"(17.2)

Ø 1.62"(42.5)

9.06"(230)

Ø 3.38"(86)

AA

13.1 ft. max.(4 m)

13.1 ft. max.(4 m)

Bw/display

Bw/display

0.98 in.(25)

1-1/2" NPT

F 6 Housing

7.18" (182.5)7.58" (192.5)

1-1/2" NPTConnector

AB

F 10 Housing

7.28" (185)8.01" (203.5)

150 lb ANSIFlange *

AB

F 6 Housing

7.23" (185)7.67" (195)

* Flanges are available in1-1/2", 2", 3" and 4" sizes

F 10 Housing

7.38" (187.5)8.11" (206)

Ø 3.38"(86)

A

Bw/display

150 lb ANSIFlange *

AB

7.08" (180)7.59" (193)

1-1/2" NPTConnector

AB

F 8 Housing

6.97" (177)7.48" (190)

Ø 3.38"(86)

Ø 0.39"(10)

Ø 1.62"(42.5)

10.2"(257)

Ø 3.38"(86)

AA

656 ft. max. *(200 m) 656 ft. max. *

(200 m)* In hazardous

areas, 328 ft. max.(100 m)

* In hazardousareas, 328 ft. max.(100 m)

Bw/display

Bw/display

0.98 in.(25)

1-1/2" NPT

F 6 Housing

7.18" (182.5)7.58" (192.5)

1-1/2" NPTConnector

AB

F 10 Housing

7.28" (185)8.01" (203.5)

150 lb ANSIFlange *

AB

F 6 Housing

7.23" (185)7.67" (195)

F 10 Housing

7.38" (187.5)8.11" (206)

Ø 3.38"(86)

A

Bw/display

150 lb ANSIFlange *

AB

7.08" (180)7.59" (193)

1-1/2" NPTConnector

AB

F 8 Housing

6.97" (177)7.48" (190)

* Flanges are available in1-1/2", 2", 3" and 4" sizes

Page 11: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

11

DB 50 S SanitaryVersion (meets 3-Asanitary standards)

Universal Mounting AdapterThe Deltapilot S DB 50 S is availablewith a universal mounting adapter,giving a high degree of flexibilityregarding existing process connections.A profiled silicone seal (optional EPDM)is provided, which is pushed on the tip ofthe probe. This seal must always beused when fitting into a process connec-tion.

The Deltapilot S with universal mountingadapter can be fitted into:• a 2” Tri-Clamp® process connector

(PN 61001739)• a weld spud for single shelled tanks

(PN 61001740)• a 2” Tuchenhagen weld spud

(PN 54001754)• an extended weld spud for insulated/

jacketed vessels (PN 61001741). Forthis option, process connection code“57” should be selected. Refer topage 13 for extended versioninformation.

NOTE: When welding the spud on thetank, we recommend the use of a weldspud plug to prevent deformation of theweld spud.

PN 61001031, 6” plugPN 61001030, 2” plugPN 012079-0002, nut coupling

Weld plug can also be used to seal thehole if the transmitter needs to beremoved.

Welded Process ConnectionsCommon flush-mounted processconnections are available for applica-tions in the food, beverage, and pharma-ceutical industry. These are supplied asstandard elastomer-free and with awelded measuring cell seal. The gap-free connections leave no residue whenindustrial cleaning procedures are used.

2” Tri-Clamp®, PN 61001739.316 L SS, clamp fastened.

Welded spud for single shell tanks, PN 61001740.316 L SS, weld fastened.

2” Tuchenhagen, PN 54001754.316 L SS, clamp fastened.

Deltapilot DB 50 S StainlessSteel Sanitary Version

Weld Spuds

Extended WeldSpud#61001741

Weld Spud#61001740

45°

RD52 x 1/6DIN 405

Ø1.87"(47.5)

Ø1.73"(44)

.08"(2)

Ø51.6)2.03"

(

Ø65)2.56"(

0.83"(21)

0.63"(16)

1.24"(31.5)

1.46"(37)1.56"

(39.5)

0.5"(12.7)

RD52 x 1/6DIN 405

Ø1.87"(47.5)

Ø1.73"(44)

Ø1.46)"

(37.2

Ø3.31)

"(84

0.28"(7.5)

0.48"(12.3)

Ø2.79)

"(71

Ø2.67)

"(68

Ø2.52)

"(64

0.63"(16)

0.73"(18.5)

1.56"(39.5)

45°

20°

RD52 x 1/6DIN 405

Ø1.73"(44)

Ø1.1.87"(47.5)

0.02"(0.5)

Ø51.6)2.03"

(

Ø64)2.52"(

0.63"(16)

1.56"(39.5)

0.47"(12)

Ø37)1.46"(

Ø56.5)2.22"

(

0.11"(2.85)

0.75"(19)

MountingAdapter

AB

F 8 Housing

8.13" (206.5)8.76" (222.5)

F 6 Housing

8.55" (217.2)8.94" (227.2)

F 10 Housing

8.12" (206.2)8.82" (224)

1.70"(43.2)

UniversalMounting Adapter

W / DIN 405 ThreadA

BW/Display

F 8Housing

1.05"(26.8)

45°

RD52 x 1/6DIN 405Ø1.87"(47.5)

Ø1.73"(44)

.08"(2)Ø

51.6)2.03"

(

Ø65)2.56"(

0.83"(21)

0.63"(16)

5.69"(144.4)

5.90"(149.9)

6.0"(152.4)

Welded spud extended, PN 61001741.316 L SS, weld fastened.When ordering 6” extension weld spudadapter, the DB 50 S must be specified withuniversal mounting adapter, 6” extension forjacketed tanks.DB 50 S - x x 57 xx x x x xx x

Stainless Steel SanitaryTri-clamp #61001739

Stainless Steel SanitaryVarivent #54001754

Page 12: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

12

Large weld spud adapter(6” extension)

Large single shell weld spudadapter (2” extension)

5.24"(133)

3.94"(100)

6.11"(152)

0.24"(6)0.80"

(20)

3.63"(92)

6.00"(152)

3.65"(93)

0.24"(6)

2.11"(53)

3.94"(100)

3.63"(92)

5.24"(133)

0.80"(20)

When ordering either of the weld spudadapters below, the DB 50 S must bespecified with universal mountingadapter, 6” extension for jacketed tanks.DB 50 S - x x 57 xx x x x xx x

DB 50 A/S extended version forinsulated or jacketed tanks(process connection code “57”)

MountingAdapter

AB

F 8 Housing

12.2" (309.9)12.9" (327.7)

F 6 Housing

13.0" (330.2)13.4" (340.2)

F 10 Housing

12.6" (320)13.3" (338)

1.70"(43.2)

AB

W/Display

Mounting adapters

Large tank weld spud, 6” extension,316L SS. PN: 84600692

Large tank weld spud, 2” extension,316L SS. PN: 84600691

Page 13: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

13

Deltapilot S DB 53 ADimensions

The DB 53 A is designed for water,wastewater, reservoirs and wells and isan ideal replacement of bubbler sys-tems. The electronics housing istypically mounted outside the well orvessel using an identical mountingbracket as used for theDB 50 A, DB 51 A, DB 50 S and DB 52 A(refer to page 14 for remote housingadapter information).

The sensor cable is hung from amounting clamp which also providestension relief. The clamp is galvanizedsteel with plastic clamping jaws (PN010527-0000). Sensor cable lengthmaximum is 656 feet (200 m). Forhazardous areas, the maximum cablelength is 328 feet (100 m). The minimumbending radius of the cable is 7.9” (200mm).

A cable shortening kit is available.PN 935666-0020 (supplied with unit)

~2.6"(66)

MountingClamp

~11"(280)

10.2"(257) Ø 1.67"

(42.5)

Page 14: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

14

Accessories Housing AdapterIn applications where the electronics isrequired to be remote mounted, awall /pipe (2”) mounting bracket isavailable. Mounting with the remotehousing adapter enables problem-freemeasurement even under the mostdifficult measuring conditions. Inapplications that are very damp or wherethe installation point is inaccessible dueto mounting height restrictions, theelectronics can be mounted 16.5 feet(5 m) or up to 65.5 feet (20 m) from thesensor.

A cable shortening kit is available fromEndress+Hauser (PN 935666-0020).Once the sensor is mounted to thevessel, the remote adapter is pressedonto the sensor and locked in place witha set screw. The sensor and adapter areNEMA 6P (IP 68) rated at the installationpoint (refer to the diagram at the bottomof page 8).

Wall Mounting

2” Pipe Mounting

Pg21

BW/Display

A

1.65"(42)

Ø1.69"(Ø43)

6.85"(174)

3.39"(86)

2.73"(70)

1.09"(28)

Ø0.24"(Ø6.2)

F 6 Housing

10.3" (262)11.1" (281)

MountingHeight

AB

F 10 Housing

10.6" (269)10.6" (269)

F 8 Housing

10.2" (260)10.9" (276)

BW/Display

A

Ø2.35"(Ø60.3)

Ø0.18"(Ø3)

F 6 Housing

11.02" (280)11.78" (299)

MountingHeight

AB

F 10 Housing

11.30" (287)11.30" (287)

F 8 Housing

10.91" (277)11.54" (293)

For separate mounting of the F6/F10/F8housing and electronic insert• Material: 304 SS• Housing adapter with 16.5 ft cable Order No: HDB50-A (PE)

HDB50-C (FEP)• Housing adapter with variable length

cable (specify 3 ft. to 98 ft)Order No: HDB50-B (PE)

HDB50-D (FEP)• Mounting bracket Order No: 919806-1000• Cable shortening kit Order No: 935666-0020• Sensor cable - minimum bending radius, 8” (200 mm) - maximum cable length, 656 ft (200 m); hazardous areas, 328 ft (100 m)

Page 15: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

15

Accessories (con’t)

FHB 20 Operating ModuleAn optional operating module withdisplay is available for use with theFEB 22, FEB 24 and FEB 26 electronicinserts. The operating module isplugged directly into the electronic insertand provides user-access to the pro-gramming matrix.• 4-digit LCD displays programmed

values and measured values• Segmented bar graph indicates

4 to 20 mA output signal• Error indicator• Operating push buttons• Matrix position indicatorsSystems specified with the FHB 20operating module are shipped with theappropriate housing cover with viewingwindow.Systems ordered blind (without display)can be retrofitted with the FHB 20display. The appropriate housing coverwith viewing window must be ordered toallow for display height.

F 6 aluminum - PN 942828-0010F 10 plastic - PN 942828-0001F 8 SS - PN 942828-0100FHB 20 - PN 942512-0100

FHB 20 Operating / Display Modulefor FEB 22, FEB 24 and FEB 26 Inserts

Protective HoodA polymide protective hood is availablefor the plastic (F 10) or aluminum (F 6)electronics housing. The hood slips overthe electronics housing as a sunshieldfor outdoor mounting locations andhelps to minimize condensation build-upinside the electronics housing.

NOTE: The hood does not protect theelectronics from harsh environments norextreme temperature fluctuations. Theambient temperature range must bemaintained. Maximum 158°F (70°C)

Order PN 942262-0001

5.4"(137)

6.1"(155)

4.33

"(1

10)

Rhodium Plated Measuring CellEndress+Hauser offers a specialmeasuring cell for applications withmaterials where hydrogen formation canoccur, such as digested sludge. Consultfactory for further information.

Page 16: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

16

Electrical Connection FEB 22 / FEB 22 P 4 to 20 mA, HART®

Protocol Electronic InsertsSmart (HART® protocol) loop-poweredelectronic inserts provide a digitalcommunication signal and a 4 to 20 mAanalog signal simultaneously withoutinterference. Terminals 1 and 3 allowconnection of a test multimeter withoutbreaking the current loop.

NOTE: The housing must be groundedwhen using the FEB 22 P insert withover-voltage protection.

The use of industrial shielded instrumentcable is recommended. If un-shieldedcable is used, electromagnetic interfer-ence may effect the digital communica-tion signal.In non-hazardous applications, themaximum shielding effect is assuredwhen the cable shield is grounded atboth ends.

FEB 22 / FEB 22 P Electronic Insert

FEB 22 Load Diagramwith Communication, min. Rb = 250 ΩΩΩΩΩ

FEB 22 Load Diagramwithout Communication

NOTE: In hazardous areas, only oneend of the shield is grounded. Thegrounded end should be at the sensor.Always observe local regulations andcodes for hazardous area wiring.

_

_

+

+1 2

I- I+

3 4

Transmitter Power Supply11.5 to 30 VDC

30

818

FEB 22 Ub / V

Rb / Ω

30

820

Ub / V

Rb / Ω

FEB 24 / FEB 24 P Electronic Insert

FEB 24 / FEB 24 P PROFIBUS-PAElectronic InsertThe digital communication signal istransmitted via a two-wire cable at thebus. The bus cable also carries thepower supply. The FEB 24 insert isconnected to a segment coupler whichprovides PROFIBUS RS-485 output forconnection to a PLC or personalcomputer. Power supply for non-hazardous areas is 9 to 32 VDC. Forhazardous areas, the power supplyrequired is 9 to 24 VDC. For localoperation, the FHB 20 display can bespecified.Connection to a PROFIBUS systemrequires two-wire twisted cable withshield for installation with the followingspecifications:• Loop resistance (DC),

15 to 150 Ω/km• Inductance per unit length,

0.4 to 1 mH/km• Capacitance per unit length,

80 to 200 nF/km

NOTE: The housing must be groundedwhen using the FEB 24 P insert withovervoltage protection.

1

PA- PA+2 3

PA- PA+

PROFIBUS-PA

Page 17: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

17

FEB 26 FOUNDATION Fieldbus ElectronicInsert

FEB 26 FOUNDATION FieldbusElectronic InsertThe digital communication signal istransmitted to the bus via two-wireconnecting cable. The bus cable alsocarries the power supply:• Power supply:

Nonhazardous, 9 to 32 VDCIntrinsically safe, 9 to 24 VDC

• Bus cable:Use twisted pair, shielded two-wirecable. Further information on the typeof cabling can be found in the FFspecification or in IEC 61158-2

Further information on connecting andgrounding the network is given at thefollowing web site:

http://www.fieldbus.org

1

FF- FF+2 3

FF- FF+

FOUNDATION Fieldbus

Bus Address FEB 24 / FEB 24 P with PROFIBUS PAWhen using the FEB 24 electronic insertfor connection to a PROFIBUS system,each instrument is given a uniqueaddress. The address can be set usingDIP switches inside the electronic insertor through the Commuwin II operatingsoftware (ensure DIP switch 8 is ONwhen using Commuwin software).

The DIP switches are located beneath aprotective cover on the electronic insert.• Lift the protective cover• Set the address (1 to 125) using

switches 1 through 7 (default is 126)• Set switch 8 to OFF (ON = Software

addressing)• Turn unit off and on to activate new

address

1 2 3 4 5 6 7 8

ON

Dip Switches

OFF

Electrical Connection(Con’t.)

FEB 26 with FOUNDATION FieldbusThe hardware setting for the writeprotection and simulation functions canbe made by means of two DIP switcheson the electronic insert.

1FF- FF+

2

SIMMOD

SIMMOD

SIMMOD on:Simulation on

WPM

WPM

Factory settings

WPM off:Writeprotection off

3

On On

Off

DAT moduleplug-in FHB 20

plug-in

Off

Factory settings are as follows:WP OFF: Write protection is disabled(writing is possible).SIM ON: Simulation is activated (simula-tion is possible).

DIP switch selection for simulation and writeprotection for the FEB 26 electronic insert.

Page 18: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

18

–+

FF +(Brown)

Shield(Black)

FF -(Blue)

PA -(Blue)

Not connected

Not connected

Shield(Green/Yellow)

PA +(Brown)

Deltapilot S Deltapilot S

–+

1 2 3bu

1

bn bk

2 3 M12PROFIBUS-PA

Shield –+

1 2 3bu

1

br gn/ye

2 3 7/8"Foundation Fieldbus

Shield

View of pins, instrument plug

M12 plug connection (PROFIBUS-PA)Endress+Hauser provides an M12 plugfor direct connection of the Deltapilot Sto your PROFIBUS network using pre-wired cable.

7/8” FOUNDATION FieldbusconnectionEndress+Hauser also provides theDeltapilot S with a 7/8” plug whichallows direct connection to your FOUN-DATION Fieldbus network using pre-wired cable.

Refer to Deltapilot order codes for cable selection.

Exchanging Electronic InsertsElectronic inserts may be exchanged.When exchanging the “P” versions(over-voltage protection), ensure that theground wire is firmly connected to theinternal housing ground terminal andterminal 4. Check the resistancebetween terminal 4 and the externalground. It must be less than or equal to0.1 Ω.

Connecting the DAT ModuleData specific to the measuring cell ispermanently stored in the DAT module.Should the DAT module require replace-ment, it can easily be exchanged. Aretaining wire with loop is attached to theinternal housing ground lug to preventloss of the DAT module. Remove theground lug screw, remove loop, andremove the DAT module from its recep-tacle. After the new module is inserted,ensure that the loop wire is secured tothe grounding lug.

DAT Receptical

DAT Module

DAT RetainerLoop

NOTE: If the DAT module is lost ordamaged, a new DAT has to be pro-grammed with the sensor specific data.Please provide serial number of trans-mitter when requesting new DATmodule.

FHB 20 Module InstallationThe FHB 20 module can be retrofitted toany of the FEB 22/22P, FEB 24/24P orFEB 26 electronic inserts for localoperation and display function. Themodule can be orientated in anydirection (in 90° increments). Plug theconnector into the FHB 20 receptacal,plug the display into the center hole ofthe electronic insert.

-

Insert FHB 20display into centerhole.

Insert plug intoreceptacal fordisplay powerand operation

Page 19: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

19

Technical Data Manufacturer Endress+HauserInstrument Designation Deltapilot SDeltapilot S Instrument used for continuous measurement of level in liquids, pastes

and sludges

Measuring Principle Conversion of the hydrostatic pressure of a column of liquid into alevel-proportional signal.

Modularity Pressure sensor DB 5XX with electronic insert FEB XX- DB 50A, DB 50S, compact version- DB 51A, rod extended version- DB 52A, DB 53A, cable extended version

Signal Transmission Dependent on electronic insert specified- FEB 22/22 P (HART): 2-wire, 4 to 20 mA output signal (Smart)- FEB 24/24 P (PROFIBUS-PA): 2-wire, digital communication signal output- FEB 26 (FOUNDATION Fieldbus): 2-wire, digital communication

Measuring Ranges 0 to 1.5 psi (0 to 100 mbar) -1.5 to 1.5 psi (-100 to 100 mbar)0 to 6.0 psi (0 to 400 mbar) - 6.0 to 6.0 psi (-400 to 400 mbar)0 to 15 psi (0 to 1200 mbar) -13 to 15 psi (-900 to 900 mbar)0 to 60 psi (0 to 4000 mbar) -13 to 60 psi (-900 to 4000 mbar)

Turndown 10 : 1Zero Point Shift 90% of measuring range

Electronic Insert Type FEB 22/22POutput Signal 4 to 20 mA, HART®

Load (without communication) Ub = 30 V, max. 818Ω max. 25Ω/wire

(with communication) FEB 22/22 P (HART), Ub = 30 V max. 800 Ω

Over-range Signal Optional 3.6 mA, 22 mA or hold (last current value)Integration Time 0 to 99 seconds, factory default set at 0 SIntegrated Over-voltage Protective diodes: Gas discharger 230 V, nominal surgeProtection current 10 kA

Electonic Insert Type FEB 24/24 POutput Signal Digital communication signal, PROFIBUS-PAPA Function SlaveTransmission Rate 31.25 kBit/sResponse Time Slave, approx. 20 ms; PLC, 300 to 600 ms (depending on segment coupler)

for approx. 30 devicesSignal on Alarm Selectable, - 9999, + 9999 or hold last valueCommunication Resistance PROFIBUS-PA termination resistorPhysical Layer IEC 1158-2Integration Time 0 to 99 seconds, factory default set at 0 sIntegrated Over-voltage Protective diodes: Gas discharger 230 V, nominal surgeProtection Current 10 kA

Electonic Insert Type FEB 26Output Signal Digital communication signal, FOUNDATION Fieldbus protocolFunction Publisher-SubscriberTransmission Rate 31.25 kBit/sSignal on Alarm Signal: Status bit set

Display module: optional -19999, +19999 or HOLD (last valid measuredvalue)

Communication Resistance FOUNDATION Fieldbus termination resistorPhysical Layer IEC 1158-2

Integration Time 0 to 99 seconds, factory default set at 0 s

Input Variables

Output Variables

Operation and System Design

Reference Conditions 77°F (25°C)Hysteresis ± 0.1% full scaleLong Term Stability 0.1% of nominal measuring range for 6 monthsEffect of Ambient Temperature 0.006% URL / 10°F (0.01% / 10K)Effect of Process Temperature 0.06% URL / 10°FLinearity 0.2% for measuring range (optional 0.1%)

Measuring Accuracy

DB 50A, DB 50S DB 51 A DB 52A, DB 53 A(compact version) (rod version) (cable version)

Mounting Orientation Any position, always Mounting from vessel top, not in filling streambelow the lowest and as far from effects of flow and turbulence asmeasuring point possible

Product Temperature Range 14°F to 212°F 14°F to 176°F 14°F to 176°F(-10° to + 100°C) (-10° to +80°C) (-10° to +80°C)

Ambient Temperature -4° to + 140°F (-20° to +60°C), with adapter housing, or for cable versions,-4° to + 176°F (-20° to + 80°C)

Storage Temperature - 40° to + 185°F (-40° to + 85°C)Maximum Cleaning Temperature For DB 50 S only, 275°F (135°C) for 30 minutes

Application Conditions(for probes with integratedelectronic insert)

Page 20: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

DB 50A, DB 50S DB 51 A DB 52A, DB 53 A(compact version) (rod version) (cable version)

Limit of Product Pressure range Measuring cell Overload Greatest Measureablepsi (bar) psi (bar) vacuum psi (bar)1.5 (0.1) 116 (8) - 1.5 (- 0.1)6.0 (0.4) 116 (8) - 6.0 (- 0.4)15.0 (1.2) 348 (24) - 13.0 (- 0.9)60 (4.0) 362.5 (25) -13.0 (- 0.9)

Climate Class D (IEC 654-1)Environmental Protection NEMA 4X (IP 66); with housing adapter, NEMA 6P (IP 68)Electromagnetic Compatibility Interference emission to EN 50081-1. Interference immunity to

EN 50082-2 and industrial standard NAMUR (field strength 10 V/m).Shock Resistance IEC 68-2-31Vibration Resistance 10 to 55 Hz, 2 g, (IEC 68-2-6)

Housing F 6 Aluminum, GD-Al Si 10 Mg, DIN 1725, with plastic coating (blue/gray).Housing cover seal, O-ring, EPDM (elastomer). *F 10 Plastic, fiberglass-reinforced polyester (blue/gray). Housing coverseal, O-ring, silicon. *F 8 SS, 304 SS, unvarnished. Housing cover seal, profiled O-ring,silicon (VMQ). **

Process Connection DB 50 A DB 51 A DB 52 A(compact) (rod version) (cable version)\

Threaded 1-1/2” NPT 1-1/2” NPT 1-1/2” NPTG 1-1/2 A (BSP) G 1-1/2 A (BSP) G 1-12/ A (BSP)

Flanged 1-1/2” 150 lb ANSI 1-1/2” 150 lb ANSI 1-1/2” 150 lb ANSI2” 150 lb ANSI 2” 150 lb ANSI 2” 150 lb ANSI3” 150 lb ANSI 3” 150 lb ANSI 3” 150 lb ANSI4” 150 lb ANSI 4” 150 lb ANSI 4” 150 lb ANSIDN 40 PN 16 Form C DN 40 PN 16 Form C DN 40 PN 16 Form CDN 50 PN 16 Form C DN 50 PN 16 Form C DN 50 PN 16 Form CDN 80 PN 16 Form C DN 80 PN 16 Form C DN 80 PN 16 Form CDN 100 PN 16 Form C DN 100 PN 16 Form C DN 100 PN 16 Form C

Clamp DB 53 A, galvanized steel with plastic clamping jaws Adapter DB 50 S, 316 L SS universal adapter for use with tank weld spud,

extended weld spud for jacketed vessels, 2” Tri-clamp, 2” welded Tri-clampor Tuchenhagen. Other process connections available: Dairy couplingDN 40, DN 50 (DIN 11851); Flange 65 mm dia. (DRD), 2” SMS coupling,68 mm varivent coupling, and IDF coupling (IS) 2853)

Process Connections Threaded and flanged versions for DB 50 A, DB 51 A, DB 52 A and allsanitary process connections for DB 50 S are 316 L SS

Rod Probe (DB 51 A) 316 L SS or Hastelloy C 4, maximum 13.2 ft. (4 m)Cable Probe (DB 52 A * / 53 A) Stranded wire cable with steel mesh, insulation Teflon (FEP), maximum

temperature 176°F (80°C) or polyethylene (PE), maximum 158°F (70°C);minimum bending radius 7.9” (200 mm); maximum cable length 656 ft.(200 m); for hazardous areas, 328 ft. (100 m)

Measuring Cell Tube 316 SSSeals Measuring cell seal DB 50 A, DB 51 A, DB 52 A and DB 53 A; optional

Viton, EPDM, Kalrez or measuring cell welded on (elastomer-free).Measuring cell seal DB 53A: Viton, EPDM or Kalrez. Optional weldedsensor (elastomer-free).Measuring cell seal DB 50S: welded, silicon profiled seal for foodstuffsas per BGA XV and FDA 177.2600. With welded flange and PTFE seal(supplied)

Process Diaphragm Hastelloy C4Protective Cap for Diaphragm For DB 51 A, DB 52 A, DB 53 A; plastic PFA perfluoralkoxy)Attachment Accessories Housing adapter for wall or pipe mounting

Measuring Cell Filling liquid, silicone oil AK 100 or TK002/500, meets USDA/H1 and FDAguidelines for use in food.

* When using remote housing adapter (DB 52 A), the max. overall length of cable is 656 ft. (200 m), and 328 ft. (100 m) for hazardous areas and comprises the total length of the support cable plus the connecting cable of the housing adapter.

Operating Module FHB 20 with FEB 22/22 PDisplay - 4 digit LC Display, with segmented bar graph, fault and communication

indicator- optional for local display and operation- plug-in unit

Operation with Display Via four keys: -, +, V, H on FHB 20 moduleOperation without Display Calibration and basic functions using four keys, -, + for 0% and -, + for

100%, located beneath protective cover on electronic insert.

20

Application Conditions(for probes with integratedelectronic insert, con’t.)

Construction

Wetted Materials

User Interface

* Glass window (with display option)** Polycarbonate window (with display option and standard/nonhazardous certificate).

Page 21: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

21

Operating Module FHB 20 with FEB 26Display - 4 digit LC Display, with segmented bar graph, fault and communication

indicator- optional for local display and operation- plug-in unit

Operation with Display Via four keys: -, +, V, H on FHB 20 moduleRemote Operation Via FOUNDATION Fieldbus

Communication InterfacesFEB 22/22 P Operation with handheld terminal

- HART communicator DXR 275 for HART protocol- Connection directly at the current output or any point in the signal lineCommunication resistance: 250Ω with Commubox FXA 191 + Commuwin II

FEB 24/24 P PROFIBUS-PASegment coupler for connection to PLC or PC, e.g. with Commuwin IIoperating program

FEB 26 FOUNDATION FieldbusVia interface card H1 direct connection to PC with operating programor via Link and interface card H1 to PC with operating program

Electronic Insert FEB 22, FEB 22 PPower Supply 11.5 to 30 VDCRipple (Smart devices) - HART max. ripple (measured at 500 Ω) 47 Hz to 125 Hz, UPP ≤ 200 mV

- Maximum noise (measured at 500 Ω) 500 Hz to 10 kHz: Ueff = 2.2 mV

Electronic Insert FEB 24 FEB 24 PPower Supply In hazardous areas: In hazardous areas

9 to 24 VDC (1.2 W) 9.6 to 24 VDC (1.2 W)Non-hazardous areas: Non-hazardous areas:9 to 32 VDC 9.6 to 32 VDC

Current Consumption 10 mA ± 1 mA

Electronic Insert FEB 26Power Supply Nonhazardous, 9 to 32 VDC

Hazardous areas, 9 to 24 VDC

Current Cunsumption 11 mA ± 1 mA

Deltapilot S Electronic inserts: FEB 22 / 22P; FEB 24 / 24P; FEB 26FM approved IS, Class I, II, III; Division 1; Groups A-GFM approved NI, Class I; Division 2; Groups A-DFM approved DIP, Class II, III; Division 1; Groups E-GCSA approved Class I, Division 1, Groups A-DCSA approved Class I, Division 2, Groups A-D

CE Mark By attaching the CE Mark, Endress+Hauser confirms the instrumentfulfills all the requirements of the relevant EC directives.

User Interface (Con’t.)

Power Supply

Approvals

Operating Module FHB 20 with FEB 24/24 PDisplay - 4 digit LC Display, with segmented bar graph, fault and communication

indicator- optional for local display and operation- plug-in unit

Operation with Display Via four keys: -, +, V, H on FHB 20 moduleRemote Operation Via PROFIBUS PA with operating program Commuwin II or PA profile

FEB 22 Insert with HART protocol Operating Instructions BA 152F/00/en Deltapilot S with PROFIBUS-PA Operating Instructions BA 164F/00/en Deltapilot S with FOUNDATION Fieldbus Operating Instructions BA 232F/00/en

Supplemental documentation

Page 22: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

22

Ordering Information, DB 50 A

Deltapilot DB 50 A -

1 CertificatesA StandardO FM approved intrinsically safe, Class I, II, III; Div. 1; Grps A-G.

Non-incendive Class I; Div. 1S CSA Class I, Div. 1T CSA Class I, Div. 2

2 Version / MaterialC Compact version

3 Process Connection / Material *12 1-1/2” NPT / 316 L SS30 1-1/2” 150 lb ANSI flange / 316 L SS31 2” 150 lb ANSI flange / 316 L SS32 3” 150 lb ANSI flange / 316 L SS33 4” 150 lb ANSI flange / 316 L SS

4 Measuring RangeFA 0 to 1.5 psi (41.55 inH

2O)

FB 0 to 6 psi (166.2 inH2O)

FC 0 to 15 psi (415.5 inH2O)

FD 0 to 60 psi (1662 inH2O)

GA - 1.5 to 1.5 psiGB - 6 to 6 psiGC - 13 to 15 psiGD -13 to 60 psi

5 Measuring Cell Type1 0.2% linearity, Silicone filled2 0.2% linearity, Fomblin (inert) filled3 0.1% linearity, Silicone filled4 0.1% linearity, Fomblin (inert) filled

Deltapilot DB 50 S -

1 CertificatesA StandardO FM approved intrinsically safe, Class I, II, III; Div. 1; Grps A-G.

Non-incendive Class I; Div. 1S CSA Class I, Div. 1T CSA Class I, Div. 2

2 Version / MaterialC Compact version

3 Process Connection / Material00 Universal mounting adapter / 316 L SS *57 Universal mounting adapter, 6” extension for jacketed tanks/316 L SS50 2” Tri-clamp / 316 L SS

4 Measuring RangeFA 0 to 1.5 psi (41.55 inH

2O)

FB 0 to 6 psi (166.2 inH2O)

FC 0 to 15 psi (415.5 inH2O)

FD 0 to 60 psi (1662 inH2O)

GA - 1.5 to 1.5 psiGB - 6 to 6 psiGC - 13 to 15 psiGD -13 to 60 psi

5 Measuring Cell Type1 0.2% linearity, Silicone filled3 0.1% linearity, Silicone filled

* Refer to page 10 and 11 for mounting adapters

Ordering Information, DB 50 S (sanitary)

6 Measuring Cell Seal1 Viton2 EPDM3 Welded5 Kalrez

7 Electronic InsertA Without insertE FEB 22, 4-20 mA, HARTG FEB 22 w/display, 4-20 mA, HARTH FEB 24, PROFIBUS-PAK FEB 24, PROFIBUS-PA w/displayR FEB 22 P, 4-20 mA, w/overvoltage, HARTT FEB 22 P, w/display, 4-20 mA, w/overvoltage, HARTU FEB 24 P, PROFIBUS-PA w/overvoltageW FEB 24 P, PROFIBUS-PA, w/overvoltage, w/display1 FEB 26, FOUNDATION Fieldbus protocol2 FEB 26, FOUNDATION Fieldbus protocol, w/display

8 Housing / Conduit EntryE1 F 6 synthetic housing, NEMA 4X / 1/2” NPTE2 F10 Aluminum housing coated, NEMA 4X / 1/2” NPTE3 F 8 SS housing, NEMA 4X / 1/2” NPT

9 Additional Options0 Without options5 Remote version with 200” cable and mounting kit7 Remote version with variable length cable and mounting kit

(max. 66 ft.)* For European style connectors, consult factory

1 2 3 4 5 6 7 8 9

6 Measuring Cell Seal3 Welded4 Viton (only with universal mounting adapter5 Kalrez

7 Electronic InsertA Without insertE FEB 22, 4-20 mA, HARTG FEB 22 w/display, 4-20 mA, HARTH FEB 24, PROFIBUS-PAK FEB 24, PROFIBUS-PA w/displayR FEB 22 P, 4-20 mA, w/overvoltage, HARTT FEB 22 P, w/display, 4-20 mA, w/overvoltage, HARTU FEB 24 P, PROFIBUS-PA w/overvoltageW FEB 24 P, PROFIBUS-PA, w/overvoltage, w/display1 FEB 26, FOUNDATION Fieldbus protocol2 FEB 26, FOUNDATION Fieldbus protocol, w/display

8 Housing / Conduit EntryE1 F 6 synthetic housing, NEMA 4X / 1/2” NPTE2 F10 Aluminum housing coated, NEMA 4X / 1/2” NPTE3 F 8 SS housing, NEMA 4X / 1/2” NPT

9 Additional Options0 Without options5 Remote version with 200” cable and mounting kit7 Remote version with variable length cable and mounting kit

(max. 66 ft.)

1 2 3 4 5 6 7 8 9

Page 23: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

23

Deltapilot DB -

51 A or 52 A

1 CertificatesA StandardO FM approved intrinsically safe, Class I, II, III; Div. 1; Grps A-G.

Non-incendive Class I; Div. 1S CSA Class I, Div. 1T CSA Class I, Div. 2

2 Version / Material / LengthG Rod probe (DB 51 A) / 316 L SS / variable (16” to 160”)P Cable probe (DB 52 A) / FEP coated steel / variable (20” to 656 ft),

non-ExR Cable probe (DB 52 A) / PE coated steel / variable (20” to 656 ft),

non-ExS Cable probe (DB 52A) / FEP coated steel / variable (20” to 328 ft), ExT Cable probe (DB 52A) / PE coated steel / variable (20” to 328 ft), Ex

3 Process Connection / Material *12 1-1/2” NPT / 316 L SS30 1-1/2” 150 lb ANSI flange / 316 L SS31 2” 150 lb ANSI flange / 316 L SS32 3” 150 lb ANSI flange / 316 L SS33 4” 150 lb ANSI flange / 316 L SS

4 Measuring RangeFA 0 to 1.5 psi (41.55 inH2O)FB 0 to 6 psi (166.2 inH2O)FC 0 to 15 psi (415.5 inH2O)FD 0 to 60 psi (1662 inH2O)GA - 1.5 to 1.5 psiGB - 6 to 6 psiGC - 13 to 15 psiGD -13 to 60 psi

Ordering Information, DB 51 A, DB 52 A

5 Measuring Cell Type1 0.2% linearity, Silicone filled2 0.2% linearity, Fomblin (inert) filled3 0.1% linearity, Silicone filled4 0.1% linearity, Fomblin (inert) filled

6 Measuring Cell Seal1 Viton2 EPDM3 Welded5 Kalrez

7 Electronic InsertA Without insertE FEB 22, 4-20 mA, HARTG FEB 22 w/display, 4-20 mA, HARTH FEB 24, PROFIBUS-PAK FEB 24, PROFIBUS-PA w/displayR FEB 22 P, 4-20 mA, w/overvoltage, HARTT FEB 22 P, w/display, 4-20 mA, w/overvoltage, HARTU FEB 24 P, PROFIBUS-PA w/overvoltageW FEB 24 P, PROFIBUS-PA, w/overvoltage, w/display1 FEB 26, FOUNDATION Fieldbus protocol2 FEB 26, FOUNDATION Fieldbus protocol, w/display

8 Housing / Conduit EntryE1 F 6 synthetic housing, NEMA 4X / 1/2” NPTE2 F10 Aluminum housing coated, NEMA 4X / 1/2” NPTE3 F 8 SS housing, NEMA 4X / 1/2” NPT

9 Additional Options0 Without options5 Remote version with 200” cable and mounting kit7 Remote version with variable length cable and mounting kit

(max. 66 ft.)

* For European style connectors, consult factory

1 2 3 4 5 6 7 8 9

Deltapilot DB 53 A -

1 CertificatesA StandardO FM approved intrinsically safe, Class I, II, III; Div. 1; Grps A-G.

Non-incendive Class I; Div. 1S CSA Class I, Div. 1T CSA Class I, Div. 2

2 Version / Material / LengthP Cable probe / FEP coated steel / variable (20” to 656 ft), non-ExR Cable probe / PE coated steel / variable (20” to 656 ft), non-ExS Cable probe / FEP coated steel / variable (20” to 328 ft), ExT Cable probe / PE coated steel / variable (20” to 328 ft), Ex

3 Process Connection / Material70 Cable probe without mounting clamp71 Cable probe with mounting clamp

4 Measuring RangeFA 0 to 1.5 psi (41.55 inH

2O)

FB 0 to 6 psi (166.2 inH2O)

FC 0 to 15 psi (415.5 inH2O)

FD 0 to 60 psi (1662 inH2O)

GA - 1.5 to 1.5 psiGB - 6 to 6 psiGC - 13 to 15 psiGD -13 to 60 psi

5 Measuring Cell Type1 0.2% linearity, Silicone filled2 0.2% linearity, Fomblin (inert) filled3 0.1% linearity, Silicone filled4 0.1% linearity, Fomblin (inert) filled

6 Measuring Cell Seal1 Viton2 EPDM3 Welded5 Kalrez

7 Electronic InsertA Without insertE FEB 22, 4-20 mA, HARTG FEB 22 w/display, 4-20 mA, HARTH FEB 24, PROFIBUS PAK FEB 24, PROFIBUS PA w/displayR FEB 22 P, 4-20 mA, w/overvoltage, HARTT FEB 22 P, w/display, 4-20 mA, w/overvoltage, HARTU FEB 24 P, PROFIBUS PA w/overvoltageW FEB 24 P, PROFIBUS PA, w/overvoltage, w/display1 FEB 26, FOUNDATION Fieldbus protocol2 FEB 26, FOUNDATION Fieldbus protocol, w/display

8 Housing / Conduit EntryE1 F 6 synthetic housing, NEMA 4X / 1/2” NPTE2 F10 Aluminum housing coated, NEMA 4X / 1/2” NPTE3 F 8 SS housing, NEMA 4X / 1/2” NPT

9 Additional Options0 Without options5 Remote version with 200” cable and mounting kit7 Remote version with variable length cable and mounting kit

(max. 66 ft.)

Ordering Information, DB 53 A

1 2 3 4 5 6 7 8 9

Page 24: TI257F Deltapilot S - Axon AutomationH/menu/docs/TIs/Pressure/... · compensation of fill fluid ensures accurate measurement under ... The weight of a column of liquid gener-ates

United States

Endress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143Phone: (317) 535-7138888-ENDRESSFAX: (317) 535-8498

TI 257F/24/ae/03.03© 2003 Endress+Hauser, Inc.

Canada

Endress+HauserCanada Ltd.1440 Graham’s LaneUnit 1, BurlingtonON, L7S 1W3Phone: (905) 681-9292800-668-3199FAX: (905) 681-9444

Mexico

Endress+HauserPaseo del Pedregal No. 610Col. Jardines del Pedregal01900, Mexico D.F.MexicoPhone: (525) 568-2405FAX: (525) 568-7459

For application and selection assistance,in the U.S. call 888-ENDRESS

For total support of your installed base, 24 hoursa day, in the U.S. call 800-642-8737

Visit us on our web site, www.us.endress.com

Endress+HauserThe Power of Know How

Measuredvalue

Set4 mA

Set20 mA

Confirm 20 mAAutomatically

Set biaspressure

Set biaspressureautomatically

DampingOutputon alarm

SelectPressure unit

Confirm 4 mAautomatically

Software no. Sensor DataNumber

Sensor DataValue Reset

Lastdiagnosticcode

Outputcurrent

OffSimulation

CurrentSimulated

Off CurrentOutput min.4 mA

Sensorpressure

LowSensorCalibration

Lower LimitRange

Upper LimitRange

Currentdiagnosticcode

HighSensorCalibration

BasiccalibrationV0

V1

H0 H1 H3H2 H4 H5 H6 H7 H8 H9

V2

V3 to V6

V7

V8

Transmitterinformation

SensorData

Descriptor

Display field

User text Serial no. Sensorserial number Seal Process

diaphragm Oil fill

Lock / unlockRelease V2H7V2H8

Pressurebefore biascorrection

Measurementpoint

V9

VA

Service

Commu-nication

Deltapilot S HART® Program Matrix

Pressure Units Conversion Table

1

10

10

10

100

9.807

9.807 x 10

1.013 x 10

3.386 x 10

133.3

249.1

6.895 x 10

3

6

5

4

5

3

3

10

10

100

0.1

9.807 x 10

98.07

101.3

3.386

0.1333

0.2491

6.895

-3

3

-3

1

10

10

0.1

10

9.807 x 10

0.0981

0.1013

3.386 x 10

1.333 x 10

2.491 x 10

6.895 x 10

-6

-3

-4

-6

-3

-4

-4

-3

1

10

10

10

10

9.807 x 10

0.98077

1.013

0.0339

1.333 x 10

2.491 x 10

0.0689

-5

-2

-3

-5

-3

-3

1

10

10

10

10

9.807 x 10

980.7

1013

33.864

1.333

2.491

68.948

-2

4

3

-2

1

0.1020

102.0

1.020 x 10

1.020 x 10

10.20

10

1.033 x 10

345.9

13.62

25.40

704.3

5

4

4

4

1

1.020 x 10

0.0102

10.20

1.020

1.020 x 10

10

1.033

0.0346

1.362 x 10

2.54 x 10

0.0704

-5

-3

-4

-3

-3

1

9.869 x 10

9.869 x 10

9.869

0.9869

9.869 x 10

9.678 x 10

0.9678

0.0334

1.316 x 10

2.458 x 10

0.0680

-6

-3

-4

-5

-3

-3

1

2.953 x 10

0.2953

295.3

29.530

0.0295

2.891 x 10

28.910

29.922

0.0394

0.0734

2.036

-4

-3

1

7.501 x 10

7.501

7501

750.1

0.7501

0.0734

734.2

760.1

25.40

1.8650

51.71

-3

1

4.016 x 10

4.016

4016

401.6

0.4016

0.0394

393.7

406.7

13.62

0.5362

27.73

-3

1

1.451 x 10

0.14505

145.05

14.505

0.0145

1.4224 x 10

14.224

14.68

0.4912

0.0193

0.0361

-4

-3

1

Pa (N/m )

kPA

MPa

bar

mbar

mm H O

kg/cm

atm

inch Hg

mm Hg

inch H O

psi

2

2

2

2

Pa (N/m )2

FromTo kPA MPa bar atm inch Hg mm Hgmbar kg/cm2mm H O2 inch H O2 psi