Three-phase 25 kW Solar Inverter - Tabuchi America 25kW Three-phase... · 6 MPPT Inverter...

2
Designed for Distributed Solar 6 MPPT Inverter Three-phase 25 kW Solar Inverter Easy maintenance 6 Individual MPPT DC Input Strings 98.7% Efficiency Three-phase 480V AC Output – Lower BOS cost NEMA3 Eliminates the need for combiner boxes – All PV strings terminate at the inverter Remote setup and monitoring TPD-T250P6-US

Transcript of Three-phase 25 kW Solar Inverter - Tabuchi America 25kW Three-phase... · 6 MPPT Inverter...

Page 1: Three-phase 25 kW Solar Inverter - Tabuchi America 25kW Three-phase... · 6 MPPT Inverter Three-phase 25 kW Solar Inverter ... 4300 W (5200 W / output limited) 200-1000 V 500 to ...

Designed for Distributed Solar

6 MPPT Inverter

Three-phase 25 kW Solar Inverter

Easy maintenance6 Individual MPPT DC Input Strings98.7% Efficiency Three-phase 480V AC Output – Lower BOS costNEMA3Eliminates the need for combiner boxes – All PV strings terminate at the inverter Remote setup and monitoring

TPD-T250P6-US

Page 2: Three-phase 25 kW Solar Inverter - Tabuchi America 25kW Three-phase... · 6 MPPT Inverter Three-phase 25 kW Solar Inverter ... 4300 W (5200 W / output limited) 200-1000 V 500 to ...

Some specifications or aspects of appearance may be changed without notice to improve the product.

Max. input voltage Operation voltage rangeMPPT voltage rangeMin. input voltage / starting voltageOperating input current per stringNumber of MPP tracker inputs

1000 V

Input (DC)

Nominal Input power per string 4300 W (5200 W / output limited)

200-1000 V500 to 800 V200 V/200 V10 A6

Output (AC: Grid connected)Rated output power*Grid connection typeRated AC voltageRated power frequencyRated output currentPower factor at rated output power

25000 WThree-phase, 4-wire type480 V (277 V WYE)60 Hz 30 A≧ 0.99

General DataDimensions W x H x DWeightOperating temperature range

Internal consumption (night)Cooling conceptEnclosure RatingController/InterfaceCertification

Topology

950 x 640.6 x 300 mm (37.4 x 25.2 x 11.8 in)69 kg (152.1 lb)

< 8 WCooling FanNEMA3Master Box* (Required)/RS485ETL(UL 1741/1699B, CSA C22.2 No. 107.1-01,IEEE 1547a, CEC) , FCC class ATransformer-less

Three-phase 25 kW Solar Inverter

T250P6-US.2016.11.TA-1

http://www.tabuchiamerica.com

EfficiencyMax. Efficiency 98.7%

ProtectionIslanding Operation Detection: ActiveIslanding Operation Detection: Passive

Frequency shifting methodFrequency change detective method

-20℃ to +60℃ (-4°F to +140°F)Rated output until +40℃ (+104°F)

* When the Power factor is 100% during inverter operation.

* Master Box is required to use three-phase 25 kW inverter.

TABUCHI ELECTRIC COMPANY OF AMERICA, LIMITEDSAN JOSE OFFICE5225 Hellyer Avenue, Suite150 San Jose, CA 95138 USAPHONE: (408) 224-9300

Dimensions

AC UnitInverter Circuit

AC Reactor

*Required

Block Diagram

PV

String 1

Wire Box Inverter Unit

String 2

String 3

String 6

DC/DC Converter①Output limited at 5200W

With MPPT controlDC/DC Converter②

DC/DC Converter⑥

Control CircuitDetector Circuit

Master Box

DC/DC Converter③

Cooling Fan(External) Cooling Fan

(Internal)

OperatingPanel

Output

Grid

Remote Control(ON/OFF)

External Communication(RS-485)

Alarm Contact(Normally Open, Normally Closed) EMI Filter

Protector Circuit

TORONTO BRANCH OFFICE151 Yonge Street, 11th FloorToronto, Ontario, M5C 2W7, CanadaPHONE: (408) 224-9300

900 (35.4)

850 (33.5)950 (37.4)

6-M10 (6-7/16) For hole

34.6 (1.4)[SW]

134 (5.3)

308 (12.1)

300 (11.8)

640.6 (25.2)

270 (10.6)

4-φ43.7 (1.7)2-φ34.5 (1.4)

49.8 (2.0) Unit: mm (in)

CEC Efficiency 97.5%

Output limited at 5200WWith MPPT control

Output limited at 5200WWith MPPT control

Output limited at 5200WWith MPPT control