1
TECHNICAL DATA SHEET Imp. Souquet - Document non contractuel - Doc ITR/THERMO F17 GB - 10.09 CHARACTERISTICS THERMO •F17 ® o 2 metallized and armed polyester sheets 127 g/m 2 Composition o 4 thicknesses of wadding 80 g/m 2 o 6 metallized polyester sheets 20 µ o 5 thicknesses of foam 0,8 mm Thickness + 33 mm Size 1,50 x 10 ml = 15 m 2 Weight of the roll + 10 kg Stability temperature -40° C / + 80° C Reflectivity + 95 % Tensile strength L = 250 N / mm 2 • D = 270 N /mm 2 The methods of calculation used for defining the installation value (value R) appears to be barely appropriate to reflection integrators. By tacking into consideration the various modes of energy Thermal equivalence transfer and by placing at the installation between two air graps, we have a thermal barrier against heat and cold and we obtain results of saving energy as a thick insulating material of roofing bigger 200 mm acting by absorption according try in situ. Acoustic The acoustic attenuation indices referred to installation between two air attenuation gaps + concrete tiles doubled of the roof. Thickness + 33 mm 17 elements + 37 db LAYING INSTRUCTIONS ITR® insulation Tile Counter lath Rafter Ventilation air gap > 40 mm Empty of air > 40 mm Dividing wall Plaster board Coating Plinth ITR® insulation ITR® insulation ITR® insulation For the use of all of our products, it is essential to provide an overlapping of the widths between one another over a minimum of 50mm to prevent forming any thermal bridges. To ensure total tightness, cover with ALUDESIF adhesive. Be sure to comply with the applicable standards regarding the ventilation of the roof. Good installation requires good ventilation. Do not allow the product to come into contact with any source of electricity. ADVANTAGES Thermal and acoustic insulation constant in time winter as summer Resistant and unchangeable Tight against air and run off water Not harmful, not irritation and allergenic Optimum gain in volume and space Participate of savings energy and contribute to preserve ozone layer Laying on new roof or renovation, on wall and under frame Laying on the new roof Laying on the roof Laying under roof Installation against wall R = 2.36 m²K/W (BBA test report n°47726THC BS EN 12667)

Transcript of Thickness + BS EN 12667) - itr.admin-mobile.com

Page 1: Thickness + BS EN 12667) - itr.admin-mobile.com

TECHNICAL DATA SHEET

Imp

. So

uque

t - D

oc

ume

nt n

on

co

ntra

ctu

el -

Do

c IT

R/TH

ERM

O F

17 G

B -

10.0

9

CHARACTERISTICS THERMO•F17®

o 2 metallized and armed polyester sheets 127 g/m2

Composition o 4 thicknesses of wadding 80 g/m2

o 6 metallized polyester sheets 20 µ o 5 thicknesses of foam 0,8 mm

Thickness + 33 mm

Size 1,50 x 10 ml = 15 m2

Weight of the roll + 10 kg

Stability temperature -40° C / + 80° C

Reflectivity + 95 %

Tensile strength L = 250 N / mm2 • D = 270 N /mm2

The methods of calculation used for defining the installation value (value R) appears to be barely appropriate to reflection integrators. By tacking into consideration the various modes of energy Thermal equivalence transfer and by placing at the installation between two air graps, we have a thermal barrier against heat and cold and we obtain results of saving energy as a thick insulating material of roofing bigger 200 mm acting by absorption according try in situ.

Acoustic The acoustic attenuation indices referred to installation between two air attenuation gaps + concrete tiles doubled of the roof.

Thickness +

33 mm

17 elements

+ 37 dbIsolant ITR®

Tuile

Contre-Liteau

Chevron

Fixation courte pour rails F530

Ventilation> 40 mm

Tasseau

Vide d'air > 40 mm

Cloison

Isolant ITR®

Plaque de plâtre

Revêtement Plinthe Isolant ITR®

Isolant ITR®

Isolant ITR®

Tuile

Contre-Liteau

Chevron

Fixation courte pour rails F530

Ventilation> 40 mm

Tasseau

Vide d'air > 40 mm

Cloison

Isolant ITR®

Plaque de plâtre

Revêtement Plinthe Isolant ITR®

Isolant ITR®

LAYING INSTRUCT IONS

ITR® insulation

Tile

Counter lath

Rafter

Ventilationair gap > 40 mm

Empty of air > 40 mm

Dividing wall

Plaster board

CoatingPlinth

ITR® insulation

ITR® insulation

ITR® insulation

■ For the use of all of our products, it is essential to provide an overlapping of the widths between one another over a minimum of 50mm to prevent forming any thermal bridges. To ensure total tightness, cover with ALUDESIF adhesive.

■ Be sure to comply with the applicable standards regarding the ventilation of the roof.Good installation requires good ventilation.

■ Do not allow the product to come into contact with any source of electricity.

ADVANTAGES

Thermal and acoustic insulation constant in time winter as summer

Resistant and unchangeable

Tight against air and run off water

Not harmful, not irritation and allergenic

Optimum gain in volume and space

Participate of savings energy and contribute to preserve ozone layer

Laying on new roof or renovation, on wall and under frame

Laying on the new roof

Laying on the roof

Laying under roof

Installation against wall

R = 2.36 m²K/W(BBA test report n°47726THC

BS EN 12667)