9
333 Input Type Range, ˚C Range, ˚F -210 to 760 -346 to 1400 -270 to 1372 -454 to 2500 -270 to 400 -454 to 752 -270 to 1000 -454 to 1832 / -50 to 1768 -58 to 3214 100 to 1820 212 to 3300 -270 to 1300 -454 to 2372 -200 to 900 -328 to 1652 Comes with complete operator’s manual. Ordering Example: iDRN-TC, signal conditioner, and DB9-RJ12, connector adaptor, £218 + 20 = £238. The iDRN-TC and iDRX-TC signal conditioners provide highly accurate, stable, isolated measurement of thermocouple sensors. Thermocouple types are selected and the outputs are scaled with the free configuration software, or can be done at the factory for no additional charge. The T/C Signal Conditioners can accept 9 different thermocouple types: J, K, T, E, R, S, B, N, and J DIN. 2 Models (Analogue or Digital Outputs) iDRN-TC provides an analogue output that is proportional to the input signal. The iDRX-TC uses a digital RS-485 communication link. Analogue Output Model The output of iDRN-TC can be user set for 0 to 10 V, 4 to 20 mA or 0 to 20 mA. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the free Windows-based setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (iDRN Analogue Output Model) Please Specify: Thermocouple Type Temperature High & Low Output Value High & Low Example: Type J, 0°C = 4 mA, 100°C = 20 mA Digital Output Model The iDRX-TC is a digital signal conditioner which communicates over an RS-485 communication link using either a simple, straightforward ASCII ® Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters. Ethernet Connection The Optional EIS-2B iServer module can connect up to thirty-two iDRX RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iServer can also be used as a To Order (Specify Model Number) Model No. Price Description iDRX-TC £168 Digital signal conditioner with RS-485 output for Thermocouple sensors iDRN-TC 218 Signal conditioner with analogue output for thermocouple sensors iDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units) -FS Free Factory setup and scaling T/C Types J, K, T, E, R, S, B, N, J DIN 0.1°C Resolution ±1°C Accuracy 1800 Vdc Isolation 250 V/1 Min. Input Overvoltage Protection Free Setup and Configuration Software Factory Setup and Configuration Available at No Charge (for iDRN Analogue Output Models) OMEGA manufactures thousands of thermocouple probes. Please see page 2 or visit omega.co.uk Thermocouple Signal Conditioners iDRX-TC Starts at £ 168 Covered by U.S. and International patents and pending applications. PATENTED MOST POPULAR MODEL HIGHLIGHTED! NEWPORT TM simple Serial to Ethernet “bridge” or converter to connect a single iDRN RS-232 device to an Ethernet network and the Internet. Specifications Accuracy at 25°C: ±1°C Resolution: 0.1˚C Power Consumption: 2 W (84 mA @ 24 Vdc) Input Types: J, K, T, E, R, S, B, N, J DIN Input Ranges: See range chart iDRX Output: 2-wire (half duplex) RS-485 (OMEGA ® serial protocol and MODBUS serial protocol) iDRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA, 10 V compliance Thermocouple Default settings iDRN: Input Type K, Range 0 to 1000°F; Output 4 to 20 mA (custom settings available at no charge) TRANSMITTERS

Transcript of Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC...

Page 1: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

333

Input Type Range, ˚C Range, ˚F-210 to 760 -346 to 1400-270 to 1372 -454 to 2500-270 to 400 -454 to 752-270 to 1000 -454 to 1832

/ -50 to 1768 -58 to 3214100 to 1820 212 to 3300-270 to 1300 -454 to 2372-200 to 900 -328 to 1652

Comes with complete operator’s manual.Ordering Example: iDRN-TC, signal conditioner, and DB9-RJ12,connector adaptor, £218 + 20 = £238.

The iDRN-TC and iDRX-TC signal conditionersprovide highly accurate, stable, isolated measurementof thermocouple sensors. Thermocouple types areselected and the outputs are scaled with the freeconfiguration software, or can be done at the factoryfor no additional charge. The T/C SignalConditioners can accept 9 different thermocoupletypes: J, K, T, E, R, S, B, N, and J DIN.

2 Models (Analogue or Digital Outputs)iDRN-TC provides an analogue output that isproportional to the input signal. The iDRX-TC uses a digital RS-485 communication link.Analogue Output ModelThe output of iDRN-TC can be user set for 0 to 10 V, 4 to 20 mA or 0 to 20 mA. Input scaling andconfiguration of other operating parameters isaccomplished by connecting to a standard RS-232port of a personal computer and using the freeWindows-based setup software. Once configured thesettings may be stored in non-volatile memory andthe unit disconnected from the PC.Factory Setup and Configuration at No ExtraCharge (iDRN Analogue Output Model)Please Specify:

Thermocouple TypeTemperature High & LowOutput Value High & LowExample: Type J, 0°C = 4 mA, 100°C = 20 mA

Digital Output ModelThe iDRX-TC is a digital signal conditioner whichcommunicates over an RS-485 communication linkusing either a simple, straightforward ASCII® SerialProtocol or MODBUS Serial Protocol. Up to 32modules may be connected to a single RS-485 portstretching up to 1200 m without repeaters.Ethernet ConnectionThe Optional EIS-2B iServer module can connect upto thirty-two iDRX RS-485 Signal Conditioners to anEthernet network and the Internet using standardTCP/IP protocol. The iServer can also be used as a

To Order (Specify Model Number)Model No. Price Description

iDRX-TC £168 Digital signal conditioner with RS-485 output for Thermocouple sensors

iDRN-TC 218 Signal conditioner with analogueoutput for thermocouple sensors

iDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units)

-FS Free Factory setup and scaling

� T/C Types J, K, T, E, R, S, B, N, J DIN� 0.1°C Resolution � ±1°C Accuracy� 1800 Vdc Isolation� 250 V/1 Min. Input Overvoltage

Protection� Free Setup and

Configuration Software� Factory Setup and Configuration

Available at No Charge (for iDRNAnalogue Output Models)

OMEGA manufacturesthousands of thermocoupleprobes. Please see page 2or visit omega.co.uk

Thermocouple SignalConditioners

iDRX-TCStarts at

£168

Covered by U.S. andInternational patents and

pending applications.

PATENTED

MOST POPULAR MODEL HIGHLIGHTED!

NEWPORTTM

simple Serial to Ethernet “bridge” or converter to connect a single iDRN RS-232 device to an Ethernet network and the Internet.

SpecificationsAccuracy at 25°C: ±1°CResolution: 0.1˚C Power Consumption: 2 W (84 mA @ 24 Vdc)Input Types: J, K, T, E, R, S, B, N, J DINInput Ranges: See range chartiDRX Output: 2-wire (half duplex) RS-485 (OMEGA® serialprotocol and MODBUS serial protocol)iDRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA, 10 V complianceThermocouple Default settings iDRN: Input Type K, Range 0 to 1000°F; Output 4 to 20 mA (custom settings available at no charge)

TRAN

SMIT

TERS

Page 2: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

SERIAL I/O

334

� 100Ω Pt, 500Ω Pt, 1000Ω Pt

� 0.1°C Resolution� ±0.5°C Accuracy� 1800 Vdc Isolation� Free Setup and

Configuration Software� Factory Setup and

Configuration Available at No Charge (for iDRN Analogue Output models)

The iDRN-RTD and iDRX-RTDsignal conditioners provide highlyaccurate, stable, isolatedmeasurement of RTD temperaturesensors. Both models can accept 2,3, or 4 wire 100Ω PT, 500Ω PT and1000Ω PT RTDs.

2 Models (Analogue or Digital Outputs)The iDRN-RTD provides a fullyscalable analogue output that isproportional to the input signal. The iDRX-RTD uses digital RS-485communications.

Analogue Model OutputThe output of the iDRN-RTD can be user set for 0 to10 V, 4 to 20 mA or 0 to 20 mA. Input scaling andconfiguration of other operatingparameters is accomplished byconnecting to a standard RS-232port of a personal computer andusing the Windows-based setupsoftware. Once configured thesettings may be stored in non-volatile memory and the unitdisconnected from the PC.

Factory Setup and Configurationat No Extra Charge (iDRN Analogue Output Model)Please Specify:

Type and resistanceTemperature high and lowOutput Value high and lowExample: Type Pt100; 0.00385; 4-wire; 0°C = 4 mA, 100°C = 20 mA

To Order (Specify Model Number)Model No. Price Description

iDRX-RTD £168 Digital signal conditioner with RS-485 output for RTD temperature sensors

iDRN-RTD 238 Signal conditioner with analogue output for RTD temperature sensors

iDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units)

-FS Free Factory setup and scalingComes with complete operator’s manual. Ordering Example: iDRN-RTD, digital signal conditioner, and DB9-RJ12, connector adaptor,£238 + 20 = £258.

SpecificationsAccuracy at 25°C: ±0.5°CInput Types: Platinum RTD, 100Ω,500Ω or 1000Ω element (2, 3 or 4 wire,385 or 392 curve)Resolution: 0.1˚CPower Consumption: 2.4 W (100 mA @ 24 Vdc)Input Range: -200 to 850°C (-328 to 1562°F) iDRX Output: 2-wire (half duplex)RS-485 (NEWPORT® Serial Protocol and MODBUS Serial Protocol)iDRN Output: 0 to 10 V @ 10 mA max;0 to 20 mA or 4 to 20 mA, 10 VcomplianceRTD Default settings iDRN:Input PT100, 0.00385, 3-wire, range 0 to 1000°F; Output 4 to 20 mA (custom settings available at no charge)

Digital Output ModelThe iDRX-RTD is a digital signalconditioner which communicatesover an RS-485 communication linkusing either a simple, straightforwardASCII Serial Protocol or MODBUSSerial Protocol. Up to 32 modulesmay be connected to a single RS-485 port stretching up to 1200 mwithout repeaters.

Ethernet ConnectionThe Optional EIS-2B iServer modulecan connect up to thirty-two iDRXRS-485 Signal Conditioners to an Ethernet network and theInternet using standard TCP/IPprotocol. The iServer can also beused as a simple Serial to Ethernet“bridge” or converter to connect asingle iDRN RS-232 device to anEthernet network and the Internet.

OMEGA manufactures many types of RTD probes.Please see page 74 or visit omega.co.uk

RTD Signal Conditioners

iDRX-RTDStarts at

£168

Covered by U.S. andInternational patents and pending applications.

PATENTED

MOST POPULAR MODEL HIGHLIGHTED!

NEWPORTTM

Page 3: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

335

To Order (Specify Model Number)Model No. Price DescriptioniDRX-ST £201 Digital signal conditioner for strain gauges and bridge

transducers with RS-485 outputiDRN-ST 231 Signal conditioner for strain gauges and bridge

transducers with analogue output

iDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units)

-FS Free Factory setup and scaling

� Unipolar/Bipolar 30 mVto 100 mV

� 13-Bit Resolution � 10 Vdc Excitation� 0.2% FS Accuracy� 1800 Vdc Isolation� 250 Vac/1 Min. Input

Overvoltage Protection� Free Setup and

Configuration Software� Factory Setup and

Configuration Available at No Charge (for iDRN Analogue Output models)

Comes with complete operator’s manual.Ordering Example: iDRX-ST, digital signal conditioner for strain gauges and bridgetransducers with RS-485 output, CAT-285, bi-directional RS-232-RS-485 converter for iDRX series, £201 + 99 = £300.

Strain Gauge/Bridge Transducer-Signal Conditioners

The iDRN-ST and iDRX-ST signalconditioners provide highly accurate,stable, isolated measurement forstrain gauge transducers such asload cells, torque transducers, non-amplified pressure transducers,and other bridge based transducers.Both models can accept signalsfrom 30 to 100 mV full scale andprovide 10 Vdc reference voltagewhich may be used for transducer excitation.

2 Models (Analogue or Digital Outputs)The iDRN-ST provides an analogueoutput that is proportional to theinput signal and the iDRX-ST usesRS-485 Serial Communications. Analogue Output ModelThe output of iDRN-ST can be userset for 0 to10 V, 4 to 20 mA or 0 to20 mA. Input scaling andconfiguration of other operatingparameters is accomplished byconnecting to a standard RS-232port of a personal computer andusing the free Windows-based setup software. Once configured the settings may be stored in non-volatile memoryand the unit disconnected from the PC.Factory Setup and Configuration at No Extra Charge (iDRNAnalogue Output and RS-232signal conditioners)Please Specify:

Input value high and lowOutput value high and lowExcitation: 10 or 14 VdcRatiometric or non-ratiometricExample: 0 V = 4 mA, 100 mV = 20 mA,excitation 10 V, ratiometric

Digital Output ModelThe iDRX-ST is a digital signal conditioner whichcommunicates over RS-485communication link using either a simple ASCII Protocol or MODBUS Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters.Ethernet ConnectionThe optional EIS-2B iServer module can connect up to 32 iDRXRS-485 Signal Conditioners to anEthernet network and the Internetusing standard TCP/IP protocol. The iServer can also be used as asimple Serial to Ethernet “bridge” orconverter to connect a single iDRNRS-232 device to an Ethernetnetwork and the Internet.

SpecificationsAccuracy at 25°C: ±0.2% FSResolution: 13 to 15 bitExcitation: 10 V @ 30 mAPower Consumption: 2 W withoutexcitation (84 mA @ 24 Vdc), 3 W withexcitation (125 mA @ 24 Vdc)Input Ranges: 0 to 30 to 0 to 100 mVfull scaleiDRX Output: 2-wire (half duplex)RS-485 (NEWPORT® serial protocol and MODBUS Serial Protocol)iDRN Output: 0 to 10 V @ 10 mA max;0 to 20 mA or 4 to 20 mA, 10 V complianceStrain Default Settings iDRN: Inputrange 0 to 30 mV; output 4 to 20 mAexcitation 10 V ratiometric (customsettings available at no charge)

OMEGA manufactures many types ofLoad Cells. Please see page 383 or visit omega.co.uk

LCM101

LCMGD

LCM1003

SERIAL I/O

iDRX-ST £201 Covered by U.S. and International

patents and pending applications.

PATENTED

MOST POPULAR MODEL HIGHLIGHTED!

NEWPORTTM

TRAN

SMIT

TERS

Page 4: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

336

To Order (Specify Model Number)Model No. Price DescriptioniDRX-PR £184 Digital signal conditioner with RS-485 output for

process signalsiDRN-PR 218 Signal conditioner with analogue output for process signals

iDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units)

-FS Free Factory setup and scaling

Process Inputs Signal Conditioners

� Unipolar/Bipolar 400 mV to 10 Vdc, 0 to 20 mA dc

� 11 to 14-Bit Resolution � ±0.1% FS Accuracy� 14 Vdc Excitation� 1800 Vdc Isolation� 250 Vac/1 Min. Input

Overvoltage Protection (Voltage Input Only)

� Free Setup and Configuration Software

� Factory Setup andConfiguration Available at No Charge (for iDRN Analogue Outputmodels)

The iDRN-PR and iDRX-PR signalconditioners provide highly accurate,stable, isolated measurement ofprocess signals. Both models canaccept unipolar and bipolar signalsfrom 400 mV to 10 Vdc full scale, as well as 0 to 20 mA current range.The Signal Conditioners alsoprovide a 10 Vdc or 14 Vdcreference voltage which can beused for transducer excitation.

2 Models (Analogue or Digital Outputs)The iDRN-PR provides aprogrammable analogue output thatis proportional to the input signal.The iDRX-PR uses a digital RS-485Serial Communications.

Analogue Output ModelThe output of iDRN-PR can be userset for 0 to 10 V, 4 to 20 mA, or 0 to20 mA. Scaling and configuration isdone with the free software on a PCusing either the standard RS-232port, or an Ethernet connection withthe optional EIS-2B module. Onceconfigured the settings are stored innon-volatile memory and the unitdisconnected from the PC.

Factory Setup and Configurationat No Extra Charge (iDRNAnalogue Output model) Please Specify:Input value high and lowOutput value high and lowExcitation: 10 or 14 VdcRatiometric or non-ratiometricExample: 0 V = 4 mA, 10 V = 20 mA,Excitation 10 V, non-ratiometric

Comes with complete operator’s manual.Ordering Example: iDRX-PR, digital signal conditioner with RS-485 output for process signals, iDRN-PS-1000, power supply, 95 to 240 Vac input, 24 Vdc output @ 850 mA, £184 + 101 = £285.

SpecificationsAccuracy at 25°C: ±0.1% FSExcitation: 14 Vdc @ 25 mAResolution: 11 to 14-bitPower Consumption: 2 W (84 mA @24 Vdc) without excitation, 3 W (125 mA @ 24 Vdc) with excitationInput Ranges: Uni/bipolar, 400 mV to 10 Vdc; 0 to 20 mAiDRX Output: 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocoland MODBUS Serial Protocol)iDRN Output: 0 to 10 V @ 10 mA max;0 to 20 mA or 4 to 20 mA, 10 VcomplianceProcess Default settings DRN:Input Range 0 to 20 mA; Output 4 to 20 mA. Excitation 14 V (customsettings available at no charge)

Digital Output ModelThe iDRX-PR is a digital signalconditioner which communicatesover an RS-485 communication linkusing either a simple straightforwardASCII Serial Protocol or MODBUSSerial Protocol. Up to 32 modulesmay be connected to a single RS-485 port stretching up to 1200 m without repeaters.

Ethernet ConnectionThe optional EIS-2B iServer modulecan connect up to 32 iDRX RS-485Signal Conditioners to an Ethernetnetwork and the Internet usingstandard TCP/IP protocol. TheiServer can also be used as asimple Serial to Ethernet “bridge” orconverter to connect a single iDRNRS-232 device to an Ethernetnetwork and the Internet.

SERIAL I/O

PXM41 Series shown, £302. OMEGA

manufactures many types ofpressure transducers. Please see

page 356 or visit omega.co.uk

iDRX-PR£184

Covered by U.S. andInternational patents and pending applications.

PATENTED

MOST POPULAR MODEL HIGHLIGHTED!

NEWPORTTM

Page 5: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

337

The iDRN-FP and iDRX-FP signalconditioners provide accurate,stable, isolated measurement offrequency and pulse signals. Bothmodels measure frequency signalsup to 50 KHz and can count up totwo million pulses. The iDRX-FPand iDRN-FP are compatible with awide variety of transducers includingproximity, switch, magnetic pickup,NAMUR, contact closure and opencollector transducers.

2 Models (Analogue or Digital Outputs)The iDRN-FP provides an analogueoutput that is proportional to the inputsignal. The iDRX-FP uses digitalRS-485 Serial Communication.

To Order (Specify Model Number)Model No. Price DescriptioniDRX-FP £168 Digital signal conditioner with RS-485 output for

Frequency/Pulse inputs iDRN-FP 198 Signal conditioner with analogue output for

Frequency/Pulse inputs

iDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 mA (powers 7 units)

-FS Free Factory setup and scalingComes with complete operator’s manual.Ordering Example: iDRN-FP, signal conditioner, and DB9-RJ12, connector adaptor, £168 + 20 = £188.

SpecificationsAccuracy at 25°C: ±0.01% FS Resolution: 15 to 19-bitPower Consumption: 2.4 W (100 mA @ 24 Vdc) without excitation, 3 W (125 mA @ 24 Vdc) with excitationInput Ranges: Frequency from 200 Hz to 50 KHz pulse from 20,000 to200,000,000 pulses full scaleiDRX Output: 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocoland MODBUS Serial Protocol)iDRN Output: 0 to 10 V @ 10 mA max;0 to 20 mA or 4 to 20 mA FP Default Settings iDRN:Input 0 to 20 KHz; Output 4 to 20 mA(custom settings available at no charge)

SERIAL I/O

Frequency/Pulse DigitalSignal Conditioners

Analogue Output ModelThe output of iDRN-PR can be user set for 0 to 10 V, 4 to 20 mA or 0 to 20 mA. Scaling and configuration is done with the free software on a PC using either the standard RS-232 port, or an Ethernet connection with theoptional EIS-2B module. Once configured the settings are stored in non-volatile memory and the unit disconnected from the PC.

Factory Setup and Configuration at No Extra Charge (iDRN Analogue Output signal conditioners)Please Specify:

Input signal or sensor typeInput frequency high and lowOutput value high and lowExcitation: 10 or 14 VdcMagnetic pickup (2-wire)Example: 0 Hz = 4 mA, 1000 Hz = 20 mA, excitation N/A

Digital Output ModelThe iDRX-FP is a digital signalconditioner which communicatesover an RS-485 communication linkusing either a simple straightforwardASCII Serial Protocol or MODBUSSerial Protocol. Up to 32 modulesmay be connected to a single RS-485 port stretching up to 1200 m without repeaters.

Ethernet ConnectionThe optional EIS-2B iServer modulecan connect up to 32 iDRX RS-485Signal Conditioners to an Ethernetnetwork and the Internet usingstandard TCP/IP protocol. TheiServer can also be used as asimple Serial to Ethernet “bridge” orconverter to connect a single iDRNRS-232 device to an Ethernetnetwork and the Internet.

�Software Selectable Input Type

�0 to 50 KHz FrequencyInput 2 Million PulseCapacity

�Proximity, Switch,Magnetic, Pickup, NAMUR,Contact Closure and OpenCollector Input Types

�RS-485 Output�1800 Vdc Isolation�Free Setup and

Configuration Software�Factory Setup and

Configuration Available atNo Charge (for iDRNAnalogue Output models)

OMEGAmanufacturesmany types of FlowTransducers. Please see page 487 or visit omega.co.uk

Please see page 487 for flowsensors or visit omega.co.uk

iDRX-FP£168 Covered by U.S. and

International patentsand pendingapplications.

PATENTED

MOST POPULAR MODEL HIGHLIGHTED!

NEWPORTTM

TRAN

SMIT

TERS

Page 6: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

338

AC Voltage/Current SignalConditioners

To Order (Specify Model Number)Model No. Price DescriptioniDRX-ACC £181 Digital signal conditioner with RS-485 output for

AC current inputiDRX-ACV 181 Digital signal conditioner with RS-485 output for

AC voltage inputiDRN-ACC 231 Signal conditioner with analogue output for

AC current inputsiDRN-ACV 231 Signal conditioner with analogue output for AC

voltage inputsiDRN-PS-1000 101 DIN rail mount power supply, 95 to 240 Vac inout,

24 Vdc output @ 850 mA (powers 7 units)-FS Free Factory setup and scaling

Comes with complete operator’s manual.Ordering Example: iDRN-ACV, signal conditioner, and DB9-RJ12, connector adaptor, £231 + 20 = £251.

SpecificationsAccuracy at 25°C: ±0.2% FS Resolution: 10 to 14-bitPower Consumption: 2.4 W; (100 mA @ 24 Vdc) MODEL iDRX-ACV/iDRN-ACVInput Ranges: 0 to 400 mV to 0 to 400 Vac full scaleInterface:RS-485; RJ-12 or screwterminal connectorMODEL iDRX-ACC/ACCInput Ranges: 0 to 10 mA to 0 to 5 Aac full scaleiDRX Output: 2-wire (half duplex)RS-485 (NEWPORT® Serial Protocoland MODBUS Serial Protocol)iDRN Output: 0 to 10 V@10 mAmax; 0 to 20 mA or 4 to 20 mA ACC Default Settings iDRN: Input 0 to 5 Amp; Output 4 to 20 mA (custom settings available at no charge)

SERIAL I/O

The iDRN and iDRX Series signalconditioners provide highly accurate,stable and isolated measurement ofAC voltage and current signalsacross extremely wide ranges: ACCurrent ranges from 0 to 10 mAthrough 0 to 5 A ac; AC Voltage rangesfrom 0 to 400 mV to 0 to 400 Vac.

Analogue or Digital OutputsThe iDRN-ACV and iDRN-ACCaccept ac voltage and ac currentrespectively and provide ananalogue output which isproportional to the input. The iDRX-ACV and iDRX-ACC acceptAC voltage and ac currentrespectively and transmit via RS-485 Serial Communications.

Analogue Output ModelThe Analogue Output models can

be configured for outputs of 0 to 10Vdc, 4 to 20 mA or 0 to 20 mA withthe free configuration software. The modules connect to a PC with RS-232 Serial Communications, or by Ethernet with the optional EIS-2B module. Once configuredthe settings are stored in non-volatile memory and the unit can be disconnected from the PC.

Factory Setup and Configurationat No Extra Charge (iDRNAnalogue Output Modules)Please Specify:

iDRN-ACV: Input value high and low; output value high and lowExample: 0 volts = 4 mA, 400Vac = 20 mAiDRN-ACC: Input value high and low; output value high and lowExample: 0 A = 4 mA, 5 A = 20 mA

Digital Output ModelThe iDRX-ACC (Current) and iDRX-ACV (Voltage) communicatevia RS-485 Serial Communicationsusing either simple ASCII Commandsor the popular MODBUS Protocol.Up to 32 modules may be connectedto a single RS-485 port stretchingup to 1200 m, more with RS-485repeaters.

Ethernet ConnectionThe optional EIS-2B iServer modulecan connect up to 32 iDRX RS-485Signal Conditioners to an Ethernetnetwork and the Internet usingstandard TCP/IP protocol. TheiServer can also be used as asimple Serial to Ethernet “bridge” orconverter to connect a single iDRNRS-232 device to an Ethernetnetwork and the Internet.

� Software Selectable Input Ranges iDRX-ACV: 0 to 400 mV to 0 to 400 VaciDRX-ACC: 0 to 10 mA to 0 to 5 A ac

� 14-Bit Resolution (max)� 0.2% FS Accuracy � 1800 Vdc Isolation� Free Setup and

Configuration Software� Factory Setup and

Configuration Available at No Charge (for iDRN Analogue Output models)

OMEGA offers many types of CurrentTransformers.Please visitomega.co.uk

MFO Series, £13.50 (basic unit).

RCT Series,£13.50 (basic unit).

iDRX-ACV£181 Covered by U.S. and International patents

and pending applications.

PATENTED

MOST POPULAR MODELS HIGHLIGHTED!

NEWPORTTM

Page 7: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

314

anyone they choose) alerting them to an alarm condition or updating thestatus. Leveraging the technology ofthe Internet, the engineer couldreceive a message from the iSeriescontroller on an Internet enabledpager or mobile phone. Mostremarkable is that all this can beaccomplished without a computer.The NEWPORTTM iSeries device(meter or controller) connects directlyto the ethernet network — not to theserial port of a computer functioningas a “server” and “master” to “slave”instruments connected through serialcommunications. The iSeries devices are also available with RS232,RS422, RS485 and MODBUS serialcommunications (specify the C24option). In fact, the iSeries are thefirst instruments of this type whichinclude all these serial protocols onone device, selectable from a menu.Internet AppliancesWith the EI option, these small 1⁄8 DIN and 1⁄16 DIN instruments arestand-alone Web servers. The ethernet and Web servercapability is actually embedded in the device. (The smallest 1⁄32 DIN size device must be connected to an external iServer.) The NEWPORTTM iSeries device isassigned an IP address on thenetwork and can also be assigned an easily remembered name such

Embedded InternetThe NEWPORTfi iSeries devices can connect directly to an ethernetnetwork with a standard RJ-45connector and can send and receivedata in standard TCP/IP packets.(Please specify EI or C4EI option.)The iSeries devices can serve Webpages over an ethernet LAN or evenover the Internet making it possibleto monitor and control a processthrough a web browser (such asMicrosoft Internet Explorer) fromanywhere in the facility or anywherein the world. Remote ControlFor example, using an iSeries 1⁄16 DINtemperature controller to control aheater, an engineer can monitor thetemperature, change set points oralarm points, turn the heater on andoff, or make other modifications fromanywhere on the local network, oranywhere on the Internet. The webpages are easily customised andsecure password protected access to the devices is easily controlled.And it requires absolutely no specialsoftware on the engineer's computerto view the data and “supervise” thecontroller—nothing other than a Web browser.Email and AlarmIn fact, the iSeries controller can evensend an email to the engineer (or

as “Heater1”. In fact, the devicecould be assigned an authorisedInternet IP address from an Internetservice provider and function as aWorld Wide Web server deliveringwhatever specific information iscalled for. (For an example, pleasesee www.omega.co.uk/iserver)The iSeries devices work well withconventional industrial automation,data acquisition and control programsas well as Microsoft Visual Basic andExcel. NEWPORTTM provides freesoftware and demos which makes itfast and easy to get up and runningwith many applications.

10BASE-T

10BASE-T

10BASE-T

10BASE-T

10BASE-T

i8 Controllerwith EI Option

Standard Ethernet Hub or Switch

i8 Controllerwith EI Option

i16 Controllerwith EI Option

Internet IP Address“Web Controller”

PC on LAN

PC on Internet

Ethernet LANINTERNET

i8 Panel Meterwith EI Option

i16 Controllerwith EI Option

£1511⁄16 DIN

Controller

iSeries Meters and Controllers - Direct Connection to Ethernet(Each device has own IP Address)

Embedded Internet

Rear TerminalConnections

NEWPORTTM

Page 8: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

315

CONT

ROLL

ERS

Standard Ethernet Hub or Switch

i8 Controllerwith C4EI Option i8 Controller

with C24 Option

i8 Panel Meterwith C24 Option

i16 Controllerwith C24 Option

i 32 Controllerwith C24 Option

RS485RS485

RS485

RS485

10BASE-T

10BASE-T

Standard Ethernet Hub or Switch

i8 Controllerwith C24 Option i8 Controller

with C24 Option

i8 Panel Meterwith C24 Option

i16 Controllerwith C24 Option

i 32 Controllerwith C24 Option

RS485RS485

RS485

RS485

10BASE-T

Standard Ethernet Hub or Switch

iServer

i8 Controllerwith C24 Option i8 Controller

with C24 Option

i8 Panel Meterwith C24 Option

i16 Controllerwith C24 Option

i 32 Controllerwith C24 Option

RS485RS485

RS485

RS485

10BASE-T

RS485

10BASE-T

Using iServer as HUB/Server for up to 32 Devices

Using NEWPORTTM 1⁄8 DIN iSeriescontroller with C4EI option as HUB

for up to 32 Devices

Conventional Serial Communicationconnections using PC with RS-485

Serial Communication

� A Web Serverand anEthernet Bridge

� Serves up to 32 Devices

Get Internet E-mail Notificationof Alarm Status on Your

Web-Enabled Phone or PDA.

The “iServer” is a DIN raildevice which can be ahub connecting up to 32 instruments to theEthernet and Internet.The “iServer” is both aWeb Server and anEthernet-Serial bridge.To connect to theiServer, iSeries devicesmust feature the “C24”Serial Communicationsoption. The NEWPORTTM

iServer is also compatiblewith the NEWPORT INFINITYfamily of ultra high performance digital panel meters and theNEWPORTTM iDRX family of signal conditioners. The iServercan also connect almost any RS232 or RS485 serial device to Ethernet.

The iServer is an alternate way to connect iSeriesdevices to an Ethernet LAN or Internet. Instead ofconnecting each iSeries device directly to the Ethernetnetwork, with individual IP addresses for each device,the iServer can be a HUB/server for up to 32 devices.

To Order (Specify Model Number)Model No. Description PriceEIS-2B iServer industrial MicroServer™, £131*

serves 32 devicesOptionsiDRN-PS-1000 Power supply (switching), £101

95 to 240 Vac input, 24 Vdc output @ 1 A (powers 10 units)

EIS-2B

£131

Page 9: Thermocouple Signal Conditioners - Omega Engineering · Thermocouple Signal Conditioners iDRX-TC Starts at £168 Covered by U.S. and International patents and pending applications.

Freephone 0800 488 488 | International +44(0) 161 777 6622 | Fax +44(0) 161 777 6622 | [email protected]

www.omega.co.uk

More than 100,000 Products Available!

CANADAwww.omega.caLaval(Quebec)

1-800-TC-OMEGA

UNITED KINGDOMwww. omega.co.uk

Manchester, England0800-488-488

GERMANYwww.omega.de

Deckenpfronn, Germany0800-8266342

FRANCEwww.omega.fr088-466-342

BENELUXwww.omega.nl0800-099-33-44

UNITED STATESwww.omega.com1-800-TC-OMEGAStamford, CT.

CZECH REPUBLICwww.omegaeng.cz

Karviná, Czech Republic596-311-899

TemperatureCalibrators, Connectors, General Test and MeasurementInstruments, Handheld Instruments for TemperatureMeasurement, Ice Point References, Indicating Labels,Crayons, Cements and Lacquers, Infrared TemperatureMeasurement Instruments, Recorders, Relative HumidityMeasurement Instruments, PT100 Probes, PT100 Elements,Temperature & Process Meters, Timers and Counters,Temperature and Process Controllers and Power SwitchingDevices, Thermistor Elements, Probes and Assemblies,Thermocouples, Thermowells and Head and WellAssemblies, Transmitters, Thermocouple Wire, RTD Probes

Pressure, Strain and ForceDisplacement Transducers, Dynamic Measurement ForceSensors, Instrumentation for Pressure and StrainMeasurements, Load Cells, Pressure Gauges, PressureReference Section, Pressure Switches, Pressure Transducers,Proximity Transducers, Regulators, Pressure Transmitters,Strain Gauges, Torque Transducers, Valves

pH and ConductivityConductivity Instrumentation, Dissolved OxygenInstrumentation, Environmental Instrumentation, pHElectrodes and Instruments, Water and Soil AnalysisInstrumentation

HeatersBand Heaters, Cartridge Heaters, Circulation Heaters,Comfort Heaters, Controllers, Meters and SwitchingDevices, Flexible Heaters, General Test and MeasurementInstruments, Heater Hook-up Wire, Heating CableSystems, Immersion Heaters, Process Air and Duct,Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters

Flow and LevelAir Velocity Indicators, Doppler Flowmeters, LevelMeasurement, Magnetic Flowmeters, Mass Flowmeters,Pitot Tubes, Pumps, Rotameters,Turbine and Paddle WheelFlowmeters, Ultrasonic Flowmeters, Valves,Variable AreaFlowmeters, Vortex Shedding Flowmeters

Data AcquisitionAuto-Dialers and Alarm Monitoring Systems,Communication Products and Converters, DataAcquisition and Analysis Software, Data LoggersPlug-in Cards, Signal Conditioners, USB, RS232, RS485and Parallel Port Data Acquisition Systems, WirelessTransmitters and Receivers