Thermo Scientific Orion Chlorine XP€¦ · The Chlorine XP analyzer is recommended as a general...

4
Product Specifications PROCESS WATER ANALYSIS Markets: Drinking Water Wastewater Food and Beverage Industrial Thermo Scientific Orion Chlorine XP Multiple parameter water quality analyzer From brine and wastewater to clean drinking water, the Thermo Scientific Orion Chlorine XP analyzer provides the ultimate accuracy and stability for the measurement of routine water quality parameters. With minimal maintenance, low cost of ownership, and multiple parameter measurement in one unit, the Orion Chlorine XP analyzer provides one of the most comprehensive water quality monitoring solution on the market. High Performance & Reliability • Proven accuracy and repeatability even in harsh sample conditions (sea water, colored water, oil water) • 0-10 ppm measurement range – in most applications • Self zero calibration before each reading, enables “0” reading • Wet tested for 24 hours before shipping • 2 year warranty Low Price & Cost of Ownership • F&T Chlorine + pH, Temp (optional ORP, Conductivity, and Turbidity) in one analyzer – saves thousands of dollars over purchasing separate analyzers • Low and customizable reagent consumption (default ~0.033 ml/sample) – lasts up to 2 months at 5 minutes cycle time, providing significant reagent savings compared to other manufacturers Low Maintenance • Light source self calibration adjustment • Hands-free self cleansing of the photocell • Automatic elimination of bubbling in the photocell • Maintenance reminders and alarms (once a year on average) • Auto buffer recognition at 4, 7, and 10 Additional Features • Up to 6, 4-20mA isolated current outputs • 6 x relays • RS 485, Modbus ® protocol support • Optional Ethernet protocol to operations center The Orion Chlorine XP analyzer measures free, total, and combined chlorine, providing accurate, objective, and fast readings of chlorine in water. It minimizes the need for periodic calibrations and is compatible with all disinfectant processes. It utilizes a DPD-based measurement technology that can be configured to use the least amount of reagents while maintaining utmost accuracy.

Transcript of Thermo Scientific Orion Chlorine XP€¦ · The Chlorine XP analyzer is recommended as a general...

Page 1: Thermo Scientific Orion Chlorine XP€¦ · The Chlorine XP analyzer is recommended as a general purpose chlorine measurement analyzer along with other parameters- pH, temperature,

Pro

du

ct Sp

ecification

sP R O C E S S W A T E R A N A L Y S I S

Markets:• DrinkingWater

• Wastewater

• FoodandBeverage

• Industrial

Thermo Scientific Orion Chlorine XP

Multiple parameter water quality analyzer

From brine and wastewater to clean drinking water, the Thermo Scientific™ Orion™ Chlorine XP™ analyzer provides the ultimate accuracy and stability for the measurement of routine water quality parameters. With minimal maintenance, low cost of ownership, and multiple parameter measurement in one unit, the Orion Chlorine XP analyzer provides one of the most comprehensive water quality monitoring solution on the market.

High Performance & Reliability• Provenaccuracyandrepeatabilityeven

inharshsampleconditions(seawater,coloredwater,oilwater)

• 0-10ppmmeasurementrange–inmostapplications

• Selfzerocalibrationbeforeeachreading,enables“0”reading

• Wettestedfor24hoursbeforeshipping• 2yearwarranty

Low Price & Cost of Ownership• F&TChlorine+pH,Temp(optional

ORP,Conductivity,andTurbidity)inoneanalyzer–savesthousandsofdollarsoverpurchasingseparateanalyzers

• Lowandcustomizablereagentconsumption(default~0.033ml/sample)– lastsupto2monthsat5minutescycletime,providingsignificantreagentsavingscomparedtoothermanufacturers

Low Maintenance• Lightsourceselfcalibrationadjustment• Hands-freeselfcleansingofthephotocell• Automaticeliminationofbubblinginthe

photocell• Maintenanceremindersandalarms(once

ayearonaverage)• Autobufferrecognitionat4,7,and10

Additional Features• Upto6,4-20mAisolatedcurrentoutputs• 6xrelays• RS485,Modbus®protocolsupport• OptionalEthernetprotocoltooperations

center

The Orion Chlorine XP analyzer measures free, total, and combined chlorine, providing accurate, objective, and fast readings of chlorine in water. It minimizes the need for periodic calibrations and is compatible with all disinfectant processes. It utilizes a DPD-based measurement technology that can be configured to use the least amount of reagents while maintaining utmost accuracy.

Page 2: Thermo Scientific Orion Chlorine XP€¦ · The Chlorine XP analyzer is recommended as a general purpose chlorine measurement analyzer along with other parameters- pH, temperature,

2 ApplicationsTheChlorineXPanalyzerisrecommendedasageneralpurposechlorinemeasurementanalyzeralongwithotherparameters-pH,temperature,ORP,andflowinwaterqualitymeasurementapplications.

Drinking Water Treatment -Mostdrinkingwaterplantsusechlorineasapreferredmethodofwaterdisinfectionanddistributionmonitoring.TheChlorineXPanalyzerprovidesrapidfeedbackforchlorineadditionsforwaterdisinfectionandaccuratecheckpointforchlorinelevelsduringwaterdistribution.AsanEPAapprovedDPDmethodwithuptotwomonthsofreagentusage,theChlorineXPanalyzerdeliverssignificantcostsavingscomparedtoconventionalonemonthusagesystems.

Wastewater Treatment-Mostwastewaterplantsusechlorineasapreferredmethodofdisinfectionbeforereleasingwaterintotheenvironment.TheChlorineXPanalyzeraccuratelymeasuresbothtotalandfreechlorinecontinuouslyinthesameunitascheckpointbeforethewaterisdischarged.Thiscombinationofmeasurementseliminatestheuseoftwodifferentinstruments,resultinginoperatingcostsavingsfortheplant.

Power Generation-Powerplantsmeasurefreeandtotalchlorineforcoolingwatereffluenttomeettheregulatorylimitsforchlorinedischarge.TheChlorineXPanalyzermeasuresaslowas10ppbfortotalchlorineinseawater,wellbelowtheregulatoryrequirementofminimumdetectionlimitsinallsamplesmatrices.

Food & Beverage Manufacturing-FoodandbeverageplantsneedtomeasurechlorinebeforewatergoesthroughtheROprocessbecausechlorineshortensthelifeoftheROmembranebychemicallyreactingtothemembrane.TheChlorineXPanalyzerprovideslowleveldetection(upto10ppb)andaquickresponsetime,extendinglifespanofROmembraneswhichtranslatestolowoperatingcostsfortheplant.

Dialysis Treatment-Dialysistreatmentcentersmonitorthechlorinelevelinkidneydialysismachinestomakesurethatitdoesn’tcomeincontactwithblood.Chlorine/chloraminesinwaterusedfordialysiscanresultinseriousadversepatientreactionsordeath.TheChlorineXPanalyzermeasureslessthan0.5ppm(max.limit)totalchlorineandprovidesquickresponsetime,resultinginROlifeextensionandimprovingcarbonfilterefficiency.

Theoperatingsystemisdesignedtobesimpleandintuitive.Onceinstalledandcalibrated,theChlorineXPanalyzerautomaticallyreleasestheproperquantityofchemicalsdependingonmeasurementfrequency.TheChlorineXPanalyzercomesstandardwithchlorinemeasurementandcanbeconfiguredtomeasureanycombinationoffreechlorine,totalchlorine,andbothfreeandtotalchlorine.

Page 3: Thermo Scientific Orion Chlorine XP€¦ · The Chlorine XP analyzer is recommended as a general purpose chlorine measurement analyzer along with other parameters- pH, temperature,

3Principle of OperationsTheDPD(N,N-diethyl-p-phenylenediamine)methodforresidualchlorinewasfirstintroducedbyDr.A.T.Palinin1957.Overtheyearsithasbecomethestandardmethodfordeterminingfreeandtotalchlorineinwaterandwastewater.WhenDPDreactswithsmallamountsofchlorineatanearneutralpH,acoloreddyeistheprincipaloxidationproduct.TheDPDdyecolorismeasuredphotometricallyatwavelengthsrangingfrom490to555nanometers(nm),whichresultsinaccuratereadingofbothfreeandtotalchlorineconcentrationsinwater.

Freechlorine(hypochlorousacid+hypochloriteions)reactswiththeFreeChlorineIndicator(DPD1)causingacolorchangeinthesamplefromcleartored.ThebufferisusedtoensurereactionataconsistentpH.Themorefreechlorinethatispresent,thedarkertheredcolorthatforms.ThecolorintensityisconvertedtoppmemployingtheBeer-Lambertlaw.

Totalchlorineisoftenusedformonitoringcombinedchlorine(chloramines)levels.Combinedchlorineisthedifferencebetweenthetotalchlorineandfreechlorine.Whenfreechlorineandtotalchlorineneedtobemeasuredinsequence,theTotalChlorineIndicator(DPD3)isaddedtothesamplealreadycontainingtheFreeChlorineIndicator(DPD1)andbuffer.ThecombinedchlorinereactswiththeTotalChlorineIndicatorcausinganincreaseintheredcolor.Thetotalchlorineisdeterminedfromthecolorchangeandthecombinedchlorineiscalculatedfromthedifferencebetweenthetotalandfreechlorine.Whenonlytotalchlorinetestisneeded,theTotalChlorineIndicator(DPD4)isaddedtothesamplecausingcolorchangeandthelevelsoftotalchlorineisdetermined.

Colorimeter water outlet

Colorimeter drain

Rotating flow switch

Reagent injection

Reagent pumps

Reagentsiphon

caps

Reagentbottles

set

Control unit

Control panel

Water intake filter

I/O module

Colorimeter module

pH, Redox, temperature module

Drain cap

Samplingcell

View window

Solenoid valve Analyzing unit

Page 4: Thermo Scientific Orion Chlorine XP€¦ · The Chlorine XP analyzer is recommended as a general purpose chlorine measurement analyzer along with other parameters- pH, temperature,

Pro

du

ct Sp

ecification

s

thermoscientific.com/processwater

©2013ThermoFisherScientificInc.Allrightsreserved.ModbusisaregisteredtrademarkofSchneiderElectric.AllothertrademarksarethepropertyofThermoFisherScientificInc.&itssubsidiaries.

Cat. No. Description

CXP71 FreeChlorineonlywith2X4/20mAoutputs

CXP72 TotalChlorineonlywith2X4/20mAoutputs

CXP73 Free & TotalChlorinecombined,2x4/20mAoutputs

CXP71PH FreeChlorine+ pH + Temp.2x4/20mAoutputs

CXP72PH TotalChlorine+pH + Temp.2x4/20mAoutputs

CXP73PH Free & TotalChlorinecombined + pH + Temp2x4/20mAoutputs

CXPRGDPD1F 5SetsofDPD1reagentsforFreeChlorine

CXPRGDPD4T 5SetsofDPD4reagentsforTotalChlorine

CXPRGDPD3T 5setsofDPD3reagentsforTotalChlorine(needtobeusedwithDPD1forCXP73andCXP73PH)

Product Ordering Information

Performance

Accuracy +/-3%

Repeatability 0.5%

MinimumDetectionLimit 10ppb

Zero-Point-Adjustment Selfzerobeforeeachreading

CycleTime 2to10minutes

FlowMonitoring Rotaryflowswitch(seeAdditionalRequirementssectionforinlet/outletpressure)

Parameters FC,TC,F&TC,ORP,pH,Temp.

MeasuringRange 0to10ppm(Cl);0-14(pH)

Reliability

Warranty 2years

Validation Contactfactory

USEPAAcceptedMethod Yes

CSACertified Yes

CECertified Yes

Operations Requirements

Maintenance 1-2monthsforreagentreplacementandfiltercleaning

Calibration Every6months(pHandORPonly)

ReagentUsage DPDupto2monthsat5min.cycletime

PowerConsumption Approx.60VA

PowerSupply 100-115VAC,50/60Hz,1.0Aor200-230VAC50/60Hz,0.5A

Weight 24lbs.(11kg)

Dimensions 67cmx33cmx14cm,26’’x13’’x5.5’’(WxHxD)

Product Specifications

Options/features

Alarms Optional,seemanual

RemoteMonitoring Notyetavailable

Enclosure IP-65ratedenclosures(NEMA4equivalent)

LocalI/O 2standard4to20mAoutputs4optional4to20mAoutputs

Memory 256K

Lines 1000

EventLogger Yes

TotalRelayOnTime Yes

DisplayType 5.5”graphicmonochromatic;characterLCDwithbackgroundlightalarmsandstatus

Password Operatorandtechnician

Servicing/Maintenance Self-cleaningphotocell(minimumservicerequirement)

Additional Requirements

SampleandDrainConnection

Pressurizedsampleinletandgravitydrain

SampleTemperature 32oFto212oF(0oCto100oC)AmbientTemperature:15oFto131oF;(-10oCto55oC)

InletPressure 5-15psi

SampleConditioning Notrequired

C.C. Lynch & Associates300 Davis Avenue, Pass Christian, Mississippi 39571Regional Offices: Austin, Baton Rouge, Dallas,Houston, Lafayette, MobileToll Free: 800.333.2252Fax 228.452.2563www.cclynch.com I [email protected]