Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™...

8
CHROMATOGRAPHY Product Specifications Thermo Scientific Dionex UltiMate 3000 Diode Array and Multiple-Wavelength Detectors Fast, sensitive, and rugged UV-Vis detection Integrating hardware, software and separation chemistry, Thermo Fisher Scientific offers UHPLC to everyone – for all needs – establishing the new standard in conventional LC. The Thermo Scientific Dionex UltiMate DAD 3000 detector is a high-resolution, 1024-element diode array detector (DAD) available in Rapid Separation (200 Hz) and Standard (100 Hz) versions. It operates with the Thermo Scientific Dionex Chromeleon Chromatography Data System software to provide a variety of spectra views, including 3-D plotting and automated chromatogram handling. The high resolution and low-noise performance of the DAD-3000 family makes it ideal for the most sensitive and accurate library searches and peak purity analyses. The detector is also available as a multiple wavelength detector (MWD) in Standard (100 Hz) and Rapid Separation (200 Hz) versions. • Data collection at up to 200 Hz using a maximum of eight single-wavelength data channels and one 3-D field (3-D only with DAD-3000 (RS)) for best support of ultrafast separations Standard versions operate at up to 100 Hz data collection rate for optimum support of 62 MPa (9000 psi) UltiMate 3000 Standard systems Accurate compound confirmation with a 1024-element, high resolution photodiode array Flexibility in both UV and Vis applications with 190–800 nm wavelength range Low-noise over the full spectral range using deuterium and tungsten lamps Fast and accurate wavelength verification using a built-in holmium oxide filter The detector can be upgraded with the Thermo Scientific Dionex UltiMate 3000 pH and Conductivity Monitor (PCM-3000) for accurate monitoring pH gradients Excellent reliability and reproducibility with low baseline drift (typically < 500 µAU/h) Simplified routine maintenance with front access to pre-aligned cells and lamps ID chips on flow cells and lamps for identification and life-span monitoring Chromeleon CDS software for full control and flexible data handling Front-panel display for easy monitoring of detector status to maximize uptime Flow cells for semi-micro, semi-analytical, analytical, and semi-preparative applications Flow cells available in stainless steel and biocompatible versions

Transcript of Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™...

Page 1: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

C H R O M A T O G R A P H YP

rod

uct S

pe

cificatio

ns

Thermo Scientific Dionex UltiMate 3000 Diode Array and Multiple-Wavelength Detectors Fast, sensitive, and rugged UV-Vis detection

Integrating hardware, software and separation chemistry, Thermo Fisher Scientific offers UHPLC to everyone – for all needs – establishing the new standard in conventional LC.

The Thermo Scientific™ Dionex™ UltiMate™ DAD 3000 detector is a high-resolution, 1024-element diode array detector (DAD) available in Rapid Separation (200 Hz) and Standard (100 Hz) versions. It operates with the Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D plotting and automated chromatogram handling. The high resolution and low-noise performance of the DAD-3000 family makes it ideal for the most sensitive and accurate library searches and peak purity analyses.

The detector is also available as a multiple wavelength detector (MWD) in Standard (100 Hz) and Rapid Separation (200 Hz) versions.

• Datacollectionatupto200Hzusingamaximumofeightsingle-wavelengthdatachannelsandone3-Dfield(3-DonlywithDAD-3000(RS))forbestsupportofultrafastseparations

• Standardversionsoperateatupto100Hzdatacollectionrateforoptimumsupportof62MPa(9000psi)UltiMate3000Standardsystems

• Accuratecompoundconfirmationwitha1024-element,highresolutionphotodiodearray

• FlexibilityinbothUVandVisapplicationswith190–800nmwavelengthrange

• Low-noiseoverthefullspectralrangeusingdeuteriumandtungstenlamps

• Fastandaccuratewavelengthverificationusingabuilt-inholmiumoxidefilter

• ThedetectorcanbeupgradedwiththeThermoScientific™Dionex™UltiMate™3000pHandConductivityMonitor(PCM-3000)foraccuratemonitoringpHgradients

• Excellentreliabilityandreproducibilitywithlowbaselinedrift(typically<500µAU/h)

• Simplifiedroutinemaintenancewithfrontaccesstopre-alignedcellsandlamps

• IDchipsonflowcellsandlampsforidentificationandlife-spanmonitoring

• ChromeleonCDSsoftwareforfullcontrolandflexibledatahandling

• Front-paneldisplayforeasymonitoringofdetectorstatustomaximizeuptime

• Flowcellsforsemi-micro,semi-analytical,analytical,andsemi-preparativeapplications

• Flowcellsavailableinstainlesssteelandbiocompatibleversions

Page 2: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

2 Table1.DAD-3000/MWD-3000designfeaturesandhighlights

DAD-3000/MWD-3000 Series Design Features and Highlights Their Benefit to You

Deuteriumandtungstenlampssupportawidedetectionwavelengthrangefrom190nmto800nm.

Goodsignal-to-noiseratioacrossthewavelengthrange.Highapplicationflexibility.

A1024-elementphotodiodearrayoptimizesspectralresolution. Accuratecompoundconfirmation.

Uptoeightchannelsofsingle-wavelengthdatacollection.Simultaneously,theDADcanacquire3-Ddata.

Simultaneousquantitationunderindividually-optimizedconditions.

Upto200Hzdatacollectionrate,including3-Ddata(underChromeleon7.1softwarecontrol).

Bestchromatographicseparationefficiencyevenwithultrafastseparations.

Excellentlinearity,typicallyupto2.0AU.Combinesdrugassayandimpurityprofilinginpharmaceuticalanalysiswithnoneedtoreinjectatadifferentdilution.

VariableslitforRapidSeparationversionsoftheDADandtheMWD.Achievebestspectralresolutionwiththenarrowslitsetting,improvenoiseperformancewiththewideslitsetting.

Flowcellrangecoverssemi-micro,semi-analytical,analytical,andsemi-preparativeflowrateapplications,instainlesssteelandbiocompatibleversions.

Flowcelleasilyadaptabletothecolumnformatinuse.

UpgradeanMWDtoaDADfor3-DUVfieldacquisitionsupport.Splityourinvestmentindiodearraytechnology.Purchasetheinstrumentyouneedtodayandadaptittoyourfutureapplicationneedslater.

Fastandtool-freeexchangeoflampsandflowcellsfromthedetectorfront.

Maintenancetasksareeasytodo.

LampsandflowcellsequippedwithIDchipsforidentification(e.g.,typeandserialnumber)andlifespanmonitoring.

HistoryistraceableevenwhentheflowcellorlampisplacedinanotherDAD-3000orMWD-3000seriesmodule.

Chromeleonsoftwaremonitorsthelifespanofthelampsandalertsuserswhentochangethem.

Enablesuserstoplanaheadforrequiredmaintenanceincreasingoverallproductivity.

Qualificationperiodissavedinthemodule.Avoidstheuseofunqualifiedequipment,evenwhenthemoduleisswitchedtoanothersystem.

PowerfulChromeleonsoftwaretoolsallowimmediateon-linereviewof3-Ddataandextractionofsinglewavelengthchannelsfromthe3-Dfield.Thesoftware’sadvancedsearchandpeakpurityalgorithmshelpyoutoquicklycreatespectralibrariesandidentifyunknowncompoundsaswellasimpurities.

Makesiteasy,fast,andconvenienttoextracttheinformationyouneed.

PCM-3000upgradeforpHandconductivitymonitoring.ThecombinationofUV-VisdetectorandPCM-3000isidealformonitoringsalt-orpH-gradientseparationsfore.g.monoclonalantibodiesorotherbiomolecules.

Page 3: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

3Design OverviewTheDAD-3000opticalbenchdesignincludestwolightsources–deuteriumandtungstenlamp–togetherwith1024diodesandpowerfulelectronics(Figure1).Polychromaticlightpassesthroughtheflowcell.Thedispersedwavelengthsaresimultaneouslydetectedbythediodearray.Thisensuresthesamesensitivityforsingle-andmulti-wavelengthoperation,providingconvenient,optimized,andsensitivequantificationofmaincompoundsandrelatedimpurities.

Reliable QuantificationNoiselevelswhenusingthewideslitare±8 µAUwithatypicalbaselinedriftof<0.5 mAU/hat254nm(flowingmobilephase).Thelownoiseandbaselinedriftallowfordetectionofweaksignals(goodsignal/noiseratio)andconsistent,reproducibleintegration.Atypicaldetectorlinearityupto2.0AUshowscorrelationcoefficientsof>0.999andaresidualstandarddeviationbelow5%withcaffeine.Thewidelinearityrangeallowsreliablequantificationofprimaryandsideproductsinthesamerun.

Sensitivity and Spectral ResolutionWhenacquiringspectraldataforpeakidentificationand/orpeakpurityanalysis,highresolutionspectraareessential.Atthesametime,itisimportanttoobtaingoodsignal-to-noiseratiosfordetectionofweaksignals.TheDAD-3000’sfamilyelectronicsaredesignedtoprovidehighspectralresolutionincombinationwithlownoise.

Figure2showsanexampleofanexplosiveresidueanalysis.Onesamplewasautomaticallyinjectedontwocolumnsofvaryingselectivity.Targetanalyteswereconfirmedbyspectralmatch,evenatverylowconcentrations.Chromeleon’scustomizablereportingfunctionsprovideinstantaneousaccesstoresults,listconfirmedorunconfirmedtargetanalytes,quantifythesubstances,anddefinetheirpeakpurity.

Figure2.DAD-3000examplefollowingEPAmethod8330forexplosivesresidues.Acustomizedreporttakesresultsfrombothseparationsandvisualizesifacompoundisconfirmedandpure.

Figure1.Lightfromthetungstenlampisfocusedthroughanapertureinthedeuterimlamp.Thecombinedlightthenpassesthroughtheflowcellanddiffractiongratingtothediodearray.

Holmium OxideFilter 1024-Element

Diode Array

Flow Cell

Deuterium Lamp

Tungsten Lamp

Grating

Variable Slit*

*Only available on DAD-3000RS and MWD-3000RS

–1

15

mAU

2

7

89

10 11

12

13

14

254 nm

0 5 10 15 20 25 30 35 40–1

15

mAU

Minutes

2

7

10

12

13

14

8 9

254 nm

Contaminated soil sampleThermo Scientific™ Acclaim™ Explosives Column E1

Contaminated soil sampleAcclaim Explosives Column E2

Page 4: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

4 Rapid Separation LC DetectorsAtypicalpeakrequires30 datapointsforaccurateandpreciseintegration.Up-to-dateUHPLCseparationscanresultinverynarrowanalytepeaks.Thesecanevenreachwidthsofonly0.25s,requiringmorethan100Hzdatacollectionrate.

TheRapidSeparationdiodearraydetectorseasilymeetthisrequirementwithdatacollectionratesofupto200Hz.Thisdetectorperformanceprovideshighlyaccurate,preciseintegrationandretentiontimerecognitionforanyseparationchallenge.

Figure3showshowdetectorswithnon-sufficientdatacollectionratescompromisethepeakintegration.Peakareaprecisionandretentiontimerecognitionareadverselyaffectedatthesametime.

UV Spectra AcquisitionTheDAD-3000RSprovidesuptoeightsingledatachannelsandfullspectralscansat200Hzforeventhemostchallengingapplications.Figure4showstheseparationof10analytes,uracilandninealkylphenones,in10seconds.Thefullspectralscancaneasilykeepupwiththisspeed.PeakidentificationandpeakpurityanalysisareasconvenientandpowerfulasforconventionalLCseparations.Combiningthesefeatureswiththelownoisespecification,theDAD-3000RSisidealforultrafastanalysesandreadytomeetfuturechallenges.

Optimize for Best Sensitivity or Spectral ResolutionBothrapidseparationversions,theDAD-3000RSandtheMWD-3000RS,provideavariableslitattheentranceofthespectrograph.Thisisaneffectivetooltofurtheradaptthedetectortotheapplicationrequirements.Anarrowslitprovidesthehighestspectralresolution,resolvingevenveryfineabsorbancespectra,suchasforpyrene(Figure5).However,UVabsorbancebandsaretypically30nmandwider.Inthesecases,abroadslitresultsinthehighestdetectionsensitivity.Morelightpassesthroughthespectrograph,reducingbothshort-termnoiseandthelimitofdetection.

Figure3.UltrahighdatacollectionratesperfectlysupporttheintegrationofthesharpestUHPLCpeaksforhighestprecisionofquantificationandretentiontime.

Figure4.200HzUVspectraacquisitioneasilysupportstheseparationof10peaksin10seconds.

Figure5.ThevariableslitoftheDAD-3000RSandtheMWD-3000RSisatooltooptimizeforbestspectralresolutionorbestdetectionsensitivity.

0

10

Seconds

0

60

190

Typically 30% noise reduction

400

%

nm

Narrow Slit

Wide Slit

200 Hz 100 Hz 50 Hz 20 Hz

0.25 seconds

Page 5: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

5Rapid Multiple Channel DetectionTheRapidSeparationversionoftheMultipleWavelengthDetectoroffershighspeedandsensitivityforbothsingleandmultiplewavelengthdataacquisition.Itsdiodearraytechnologyachievesmulti-channeldetectionofuptoeightchannelswithoutmovingparts.

Regardlesshowmanywavelengthsarerecorded,thedetectorcanmeasureallwavelengthsatthesamehighsensitivityandatamaximumdatacollectionrateof200Hz.Up-to-datevariablewavelengthdetectorsachievemultiplewavelengthdetectionbyrapidlyswitchingbetweenalternatewavelengths,butthisadverselyaffectsshort-termnoiseandreducesthemaximumdatacollectionratesignificantly.TheMWDdoesnothavethislimitation.

Upgrade MWD to Full DAD FunctionalityMWDdetectorsarebasedonphotodiodearraytechnology.TheonlydifferencefromDADdetectorsisthattheMWDdoesnotsupporttheacquisitionof3-Dspectra.

These3-Dspectracapabilitiesarefield-upgradable,turningyourMWDintoafull-blownDAD.Youmaythereforestaggeryourinvestmentindiodearraytechnology,purchasetheinstrumentyouneedtoday,andadaptittoyourfutureapplicationneedslater.

Ergonomic Design and Advanced System MonitoringAllfluidicpartsoftheMWDandDADdetectorseriescanbeaccesseddirectlyfromthefront.Thedoorfoldsdown,servingasaminiaturelabbenchtoplacetoolsandpartsduringmaintenance(Figure7).

Thedeuteriumandtungstenlampsofthedetectorcanalsobeaccessedfromthefrontbyopeningthefingertightnutsofthelampcover.Changingtheselampsisequallyfastandeasy.ModificationsofflowcellsorlampsareautomaticallytrackedbyintegratedIDchips.AllrelevantinformationisstoredinthelampandmoveswiththedetectorifitistransferredtoanotherLCsystem.Chromeleonconstantlymonitorstheseandvariousothercounterstoprovideyouwithearlywarningswhenapartisdueforreplacement.Inaddition,ChromeleonsoftwaremonitorsandverifiestheinstrumentqualificationstatustomeetyourGLPcompliancegoals(Figure8).

Figure7.Ergonomicinternalfrontdesign(afterremovalofflowcell/lampscovers):directaccessto1)theD2andtungstenlamps,2)theflowcell,and3)theflowcelladapterblockforeasyoperationandmaintenance.

Figure6.Sub-1minsoftdrinkanalysiswithsimultaneousacquisitionofeightdifferentUVchannels,measuredwiththeMWD-3000RS.

Figure8.DAD-3000automatedqualificationmonitoring.

1

2

3

0 10 20 30 40

87

65

43

21

Seconds

Page 6: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

6 Easy Screening with Chromeleon Spectral LibrariesChromeleonsoftwaresupportseasycreationofspectrallibrariesofknowncompounds(Figure10).

Spectraofunknownpeakscanbecomparedautomaticallyagainstallspectrainalllibraries.Chromeleonsoftwarewillreporttheclosestmatches.Thelibrarycanincludefields,suchassolventcompositionandwavelengthresolution,toprovidemoreadvancedsearchcriteria.

Fast Access to Data and Results via the Peak Purity Analysis ViewViewalldatainasinglesummarywindow,usingadisplaystyleofyourchoice(Figure9).DragtheverticallinetoviewtheassociatedUVspectraatdifferentpointsofthechromatogram.Dragthehorizontallinetoseetheassociatedchromatogramfortheselectedwavelength.Thismakesiteasytofindthebestsignalresponse.Infact,Chromeleonsoftwarecanevenperformthistaskforyouautomatically.Afterthat,itisasimplesteptoextracteitherthechromatogramorthespectrumyouneed.

Getting the Most from Your Spectral Data – with EaseAtypicaldiodearray3-Dfieldcontainsavastamountofinformation.Effectivetoolsareneededtoworkwithsuchvolumesofdata.PowerfulChromeleonsoftwareputsthesetoolsatyourfingertipsandmakesiteasytoextracttheinformationyouneed.WiththeDAD-3000family,youcan:

• Reviewyourresultsinasinglewindow

• Extractsingle-wavelengthchannelsfromyour3-Dfield

• Quicklycreatespectralibrariesforknowncompounds

• Automaticallyidentifyunknownpeaksbasedonasearchofoneormorespectrallibraries

• Easilyidentifypeaksthatcontainunderlyingimpurities,usingadvancedpeakpurityalgorithms

• Effectivelyreporttheresultsinaformatofyourchoice

Figure9.Convenientextractionofasinglewavelength(250nm)from3-DfielddataofaUHPLCseparation.

Figure10.Spectrallibraryscreening.

Page 7: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

7Assess Specificity in Seconds with Peak Purity IndexThePeakPurityIndexcanbeoverlaidwithachromatogramforstraightforwardidentificationofpeaksthathaveanunderlyingimpurity(Figure11).

Apurepeakhasaconsistentpeakpurityindex.Anydeviationsindicateanunderlyingimpurity.Thisat-a-glancetechnologycanspeedmethoddevelopmentandhelptoensurespecificity.

Application FlexibilityFourdifferentflowcellsizesareavailablefortheDAD/MWD-3000series:

• AnalyticalflowcellssuitableforHPLCandsomeUHPLCapplications

• Semi-microflowcellsforbestchromatographicresolutionwithsmallIDcolumnsandnarrowanalytepeaks

• Thesemi-analyticalflowcelldesignedfor3mmIDcolumnseparations

• A0.4mmopticalpathlengthsemi-preparativeflowcellforUVdetectionofhigh-concentrationanalytes

Thiswiderangeofflowcellsmeansyoucanadaptyoursystemeasilytoyouranalyticalneeds.

Accurate pH and Conductivity MonitoringThePCM-3000isanupgradeoftheDAD-3000andMWD-3000seriesforaccurateon-linepHandconductivitymonitoring.ThecombinationofUV-ViswiththePCM-3000isidealforpHorsaltgradiention-exchangechromatographyofcompounds,e.g.monoclonalantibodies,conductivitymonitoringingradientseparationsofbiomolecules,andthereforeagreatadditiontotheThermoScientific™Dionex™UltiMate™3000BioRSsystems.

Figure11.Peakpurityexamples.

Figure12.FlowcelldesignofUltiMate3000DiodeArrayDetectors.

Part Number Description Volume (µL)

Optical Path Length (mm)

6082.0100 AnalyticalFlowCell,StainlessSteel 13.0 10.0

6082.0200Semi-AnalyticalFlowCell,StainlessSteel

5.0 7.0

6082.0300 Semi-MicroFlowCell,StainlessSteel 2.5 7.0

6082.0400 AnalyticalFlowCell,PEEK™ 13.0 10.0

6082.0500 Semi-MicroFlowCell,PEEK 2.5 7.0

6082.0600 Semi-PreparativeFlowCell,PEEK 0.7 0.4

Table2.DAD-3000andMWD-3000flowcelloptions

Figure13.ThePCM-3000isahighperformance,easy-to-use,andcosteffectivesolutionforpHandconductivitymonitoring.

7.5 9.0

Minutes

Straight lineindicates purepeaks

7.5

9.0

Minutes

Indicates underlyingco-elutingpeak

Page 8: Thermo Scientific Dionex UltiMate 3000 Diode Array and ... Upload to Web... · Chromeleon™ Chromatography Data System software to provide a variety of spectra views, including 3-D

Australia+61397574486Austria+43810282206Belgium+3253734241Brazil+551137315140China+85224283282Denmark+4570236260

Finland+358932910200France+33160924800Germany+4961034081014India+912267429494Italy+3902950591Japan+81668851213

Korea+82234208600Netherlands+31765795555Norway+46855646800Singapore+6562891190Sweden+46855646800Switzerland+41617167700

Taiwan+886287516655UK/Ireland+441442233555USA and Canada+8472957500

Thermo Fisher Scientific, Sunnyvale, CA USA is ISO 9001:2013 Certified.

www.thermoscientific.com/dionex©2013ThermoFisherScientificInc.Allrightsreserved.PEEKisatrademarkofVictrexPLC.ISOisatrademarkoftheInternationalStandardsOrganization.PEEKisatrademarkofVictrexPLC.AllothertrademarksarethepropertyofThermoFisherScientificInc.anditssubsidiaries.Specifications,termsandpricingaresubjecttochange.Notallproductsareavailableinallcountries.Pleaseconsultyourlocalsalesrepresentativefordetails.

Pro

du

ct Sp

ecifica

tion

s

PS70286_E07/13S

Specifications

Dimensions(h×w×d) 16×42×51cm(6.3×16.5×20in.)

DetectionType Single-beam,reverse-opticsdesignwithconcaveholographicgrating

MaximumData 200Hz:DAD-3000RS(including3-Dacquisition)CollectionRate) andMWD-3000RS(underChromeleon7.1software

control)100Hz:DAD-3000(including3-Dacquisition)andMWD3000

WavelengthRange 190to800nm

Noise Wideslit:<±8μAUat254nm.Narrowslit:<±10μAUat254nmresponsetime2s(accordingtoASTMtimeconstant~1s),4nmbandwidth,waterat1.0mL/min

Drift <1mAU/h(typically<0.5mAU/h)at254and520nmwithwaterat1.0mL/min

Linearity <3%RSDandcorr.coeff.>0.9995upto1.5AU,typically<5%RSDandcorr.coeff.>0.999upto2.0AU

LightSource Deuteriumlamp,tungstenlamp,temperaturecontrolforbothlamps

WavelengthAccuracy ±1.0nm,self-calibrationwithD-alphaline,verificationwithholmiumoxidefilter

WavelengthPrecision ±0.1nm

PixelResolution <1nm

SlitWidth Narroworwideslit,settablefortheDAD-3000RSandMWD-3000RS

PCConnection AllfunctionscontrollableviaUSB2.0;integratedUSBhubwiththreeUSB2.0ports

GLPFeatures AutomaticInstrumentQualification(AutoQ),SystemWellnessandQualificationMonitoringwithChromeleonsoftware,lampandcellIDchips

UserInput/Display LCDindicatingsystemparameters,standbybutton,threeLEDsforstatusmonitoring,fourfunctionkeysforinitialoperationandmaintenance

PowerRequirements 85-260V,50/60Hz,max.150W

Ordering Information

ToorderintheU.S.,call1-800-346-6390,orcontacttheThermoFisherScientificofficenearestyou.OutsidetheU.S.,orderthroughyourlocalThermoFisherScientificofficeordistributor.Refertothefollowingpartnumbers.

Detectors Part Number

DAD-3000RSRapidSeparationDiodeArrayDetector 5082.0020(withoutflowcell)

DAD-3000DiodeArrayDetector(withoutflowcell) 5082.0010

MWD-3000RSRapidSeparationMultipleWavelengthDetector 5082.0040(withoutflowcell)

MWD-3000MultipleWavelengthDetector(withoutflowcell) 5082.0030

Accessories Part Number

Analyticalflowcell,stainlesssteel,13μL 6082.0100

Semi-analyticalflowcell,stainlesssteel,5μL 6082.0200

Semi-microflowcell,stainlesssteel,2.5μL 6082.0300

Analyticalflowcell,PEEK,13μL 6082.0400

Semi-microflowcell,PEEK,2.5μL 6082.0500

Semi-preparativeflowcell,PEEK,0.7μL 6082.0600

UpgradeMWD-3000RStoDAD-3000RS 6082.3045

UpgradeMWD-3000toDAD-3000 6082.3035

PCM-3000forDAD-3000orMWD-3000Series 6082.2000(ShippedwithapHandconductivityflowcellandapHelectrode)

Deuteriumlamp 6074.1110

Tungstenlamp 6074.2000