Introduction To Thermal Power Plant (Steam power plant)
![Page 2: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/2.jpg)
Thermal Power Plants – 75%Hydro Electric Power Plants - 20%Nuclear Power Plants - 3%Installed wind power Generation – 2%30% to 40% of electrical power is lost in
transmission and distribution.
Electricity Generation Sources
![Page 3: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/3.jpg)
![Page 4: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/4.jpg)
GENERAL LAYOUT OF THERMAL POWER PLANT
![Page 5: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/5.jpg)
Coal is delivered to the plant by Railway Road Arial ropeways, .
Following are the processes depending on the capacity of
the plant.
Unloading process Feeding process Screening process Crushing process Stacking process & Reclaiming process Bunkering process
COAL HANDLING PLANT
![Page 6: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/6.jpg)
Power Plant Cycle
![Page 7: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/7.jpg)
Feed Water Cycle Steam Cycle Condensate Cycle Cooling Water Cycle
Air And Flue Gas Cycle
Power Plant Cycles
![Page 8: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/8.jpg)
Feed Water Cycle
Deaerator•Remove oxygen from feed water to steam generating boiler.•Protect from corrosions in feed water pips.•Remove unwanted dissolved CO2 gases.
![Page 9: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/9.jpg)
Boiler Feed Water Pump
Pump feed water into a steam boiler.These pumps are normally high pressure unit.These are can be of the centrifugal pump type or positive
displacement type.
Heaters
Pre-heat water delivered to steam generating boiler . Improves the thermodynamic efficiency of the system. 1. H.P Heater: (High pressure heater) -Heats the feed
water by exchanging heat with the steam that is extracted from the H.P. Turbine from different stages at different pressure.
2. L.P. Heater: (Low Pressure heater)- Heats the water but it take the steam extraction from the L.P. turbine.
![Page 10: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/10.jpg)
EconomiserTubular heat transfer surfaces used to preheat
boiler feed water before it enters the steam drum (same like heaters)
Extract heat from the flue gas before it is exhausted to the atmosphere .
Increases overall boiler thermal efficiency.
Boiler
Rectangular furnace about 50 feet (15 m) on a side and 130 feet (40 m) tall. Its walls are made of a web of high pressure steel tubes.
![Page 11: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/11.jpg)
Steam Cycle
![Page 12: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/12.jpg)
BOILER DRUM ( STEAM DRUM)
It is a reservoir of water/steam at the top end of the water tubes. It acts as a phase-separator for the steam/water mixture
SUPER HEATER
Convert wet, saturated steam into dry steam (high temp and press) known as superheating.
Dry steam contains more thermal energy and increases the overall efficiency of the cycle by increasing Turbine work.
![Page 13: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/13.jpg)
TURBINE
Extracts thermal energy from pressurized steam and convert into mechanical work on a rotating output shaft.
Steam turbines are split into three separate stages, 1) High Pressure (HP) – some fraction of steam sends to boiler
to reheat. 2) Intermediate Pressure (IP) – Reheated steam returns here
and sends to LP. 3) Low Pressure (LP)
![Page 14: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/14.jpg)
CONDENSATE CYCLE
![Page 15: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/15.jpg)
CONDENSER
Steam is condensed by exchanging heat from circulating water coming from Cooling Towers.
Pressure is maintained below atmospheric pressure.
CONDENSER TUBE MATERIAL Copper based alloy (ASTM B 111, B543) Stainless steel (ASTM A268, B268, 1249, A213, A269) Titanium (ASTM B 338 Gr 1&2) Carbon steel (ASTM A 179, A214)
![Page 16: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/16.jpg)
FUNCTION OF CONDENSER
Create a vacuum by condensing steam.
Remove dissolved non-condensable gases from condensate.
Providing a leak-tight barrier between the high grade condensate contained within the shell and the cooling water.
HOT WELL
The condenser hot well serves as a water reservoir for the turbine cycle.
Supply make-up water to the cycle.
![Page 17: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/17.jpg)
Condensate Extraction Pump (CEP)
An extraction pump is an important part of a feed water system
Generally, fitted in between the condenser and de-aerator
To maintain the amount of condensate in the condenser
To provide the sufficient suction head to the extraction pump
![Page 18: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/18.jpg)
COOLING TOWER
![Page 19: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/19.jpg)
Cooling towers are heat removal devices used to transfer process waste heat to the atmosphere
It works of the principle of heat transfer by convection. Heat lost by the water = Heat gain by the air
The towers vary in size from small roof-top units to very large hyperboloid structures (as in Image ) that can be up to 200 metres tall and 100 metres in diameter
![Page 20: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/20.jpg)
Air and flue gas cycle
![Page 21: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/21.jpg)
Flue gas is the gas exiting to the atmosphere through a pipe or channel.
Quite often, the flue gas refers to the combustion exhaust gas produced at power plants.
It usually consist of mostly nitrogen (typically more than two-thirds) from the combustion air, CO2, and water vapour as well as excess oxygen
It further contains a small percentage of a number of pollutants, such as particulate matter(like soot),carbon monoxide, nitrogen oxides, and sulphur oxides.
![Page 22: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/22.jpg)
Forced Draft Fans (FD FANS):-
Supply necessary air for fuel combustion by pushing the air through the combustion air supply system and into the furnace.
These fans are typically the most efficient fans in the power plant . Typically, these fans are centrifugal fans.
Induced Draft Fans (ID FANS):-
Placed at the outlet of the boiler system. It exhaust all gaseous combustion products, or flue gas, from the
boiler by creating a negative pressure or suction within the furnace.
Primary Air Fans (PA FANS):-
Primary air fans (PA) are high pressure fans . Supply air for the transportation of coal directly from the
pulverizer to the furnace .
![Page 23: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/23.jpg)
By lowering Condenser Pressure By ReheatingBy SuperheatingBy RegenerationModified Rankine cycle
Way To Increase efficiency of cycle
![Page 24: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/24.jpg)
Electrostatic Precipitators(ESP):-
Particulate collection devices that remove particles from a flowing gas (e.g. air) by using the force of an induced electrostatic charge.
They can easily remove fine particulate matter such as dust and smoke from the air stream.
Selection Of site:-
Availability of cheap land.Availability of water.Availability of fuel.Possibility of future expansion of the plant.Away from the urban areas due to pollution.The initial cost of plant.Magnitude and nature of load to be handled.
![Page 25: Thermal power plant](https://reader035.fdocuments.in/reader035/viewer/2022062304/55d513acbb61eb74638b45a2/html5/thumbnails/25.jpg)
THANK YOU...