Thermal Management Catalogue - Axair Fans · PDF fileAxair range of thermal management...

12
Control Panel Solutions Thermal Management Catalogue 2012 Edition

Transcript of Thermal Management Catalogue - Axair Fans · PDF fileAxair range of thermal management...

Control Panel Solutions

Thermal Management Catalogue

2012 Edition

2 Axair Fans UK Ltd 01782 349 430

...About Axair Fans UK

Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling.

Plastic Range: 9 basic sizes of polypropylene fan in plain scroll housing from stock, plus 3 sizes of in-line fan on short-lead time.

Stock Facility: Large modern warehouse facility containing a vast selection of fans, fan components and general accessories.

Customised Build: Fans assembled from standard components to create the perfect mechanical and electrical solution to safe fume extraction.

Customer Care: Experience a sense of partnership with Axair Fans.

Lowfield Drive - Centre 500 - Wolstanton - Newcastle-Under-Lyme - ST5 0UUTel: 01782 349430 Fax: 01782 349439 Email: [email protected] www.axair-fans.co.uk

All specifications, data and drawings are subject to alterations without prior notice

Axair range of thermal management accessories is specially designed for the control panel/enclosure industry. It includes a vast choice of frame fans for electronic cooling, fan filter units IP54 and IP55, roof mounted fans, PTC heaters, thermostats and lights, all ex-stock.

Call Axair now for your copy of the OEM catalogue of external rotor motor fans, frame axial fans and accessories.

Thermal Management

[email protected] 3

Fan Filter Units

Specially designed for control panels and enclosures the “FPF” range of fan filter units offer:

• Compact sizes and low external profile. • Fast mounting thanks to plastic elastic hooks. • Integrated sealing gaskets for dust and water

protection.• Available with or without the fan, or with the

fan in standard or reverse airflow on request

Standard Specifications• Standard airflow direction from the outside to the

inside of the cabinet.• Mounting without screws in square openings. - Tolerance range of 1,5mm. - Plate thickness between 1,5 and 2,2mm. • Possible fixing with V-shaped head screws (not

supplied). • Standard colour RAL703 (RAL 7032 available to order). • Washable filter media. • Shielded ball bearing fans. • IP54 (standard) or IP55 (on request) protection. • EMC version available. • Different voltages available : 24 or 48VDC, 24VAC

and 3-phase 400Volts.• Lifetime (L10) between 45000 to 70000 hours

depending on models (at typical 40°C operating temperature).

• CSA approved. • Suitable for operation at 60Hz – Please contact us for

data.

Airflow Direction

Airflow Figures

Technical data gives two sets of maximum airflow : • First is for the fan filter itself

operating at free air without exhaust filter (Point 1)

• Combined airflow (fan/filter + exhaust) (Point 2)

Product Coding System

4 Axair Fans UK Ltd 01782 349 430

Technical Specification & DataFPF08K

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CFPF08KU115B (R)-110 115 50 9 140

23 17 42 40 0.50 -10~+50FPF08KU230B(R)-110 230 50 10 70

(mm) FPF08KUG-100 FPF08KU...B(R)-110 Cut-out

FPF12K

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CFPF12KU115BE(R)-110 115 50 20 210

57 44 66 43 0.80 -10~+50FPF12KU230BE(R)-110 230 50 20 125

(mm) FPF12KUG-100 FPF12KU...B(R)-110 Cut-out

FPF13K

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CFPF13KPU115BE(R)-110 115 50 20 210

110 85 68 43 1.00 -10~+50FPF13KPU230BE(R)-110 230 50 20 125FPF13KU115BE(R)-110 115 50 22 320

120 94 84 41 1.11 -10~+50FPF13KU230BE(R)-110 230 50 22 160

(mm) FPF13KUG-100 FPF13KPU...BE(R)-110 FPF13KU...BE(R)-110 Cut-out

[email protected] 5

FPF15K

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CFPF15KPU115BE(R)-110 115 50 20 210

115 97 51 43/48 1.00 -10~+50FPF15KPU230BE(R)-110 230 50 20 125FPF15KMU115BE(R)-110 115 50 22 320

130 99 75 41/43 1.11 -10~+50FPF15KMU203BE(R)-110 230 50 22 160FPF15KU115E(R)-110 115 50 30 250

240 170 111 50/55 1.69 -10~+50FPF15KU230BE(R)-110 230 50 29 126FPF15KGU115BE(R)-120 115 50 50 540

360 230 160 61/63 3.05 -10~+50FPF15KGU230BE(R)-120 230 50 67 300

(mm) FPF15KUG-100 FPF15KPU...BE(R)110 FPF15KMU...BE(R)-110

FPF15KU...BE(R)-110 FPF15KGU...BE(R)-110 Cut-out

FPF20K

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CFPF20KU115BE(R)-120 115 50 50 540

520 405 160 61 3.62 -10~+50FPF20KU230BE(R)-120 230 50 67 300FPF20KGU115B(R)-110 115 50 95 790

660 430 220 71 3.70 -10~+55FPF20KGU230B(R)-110 230 50 140 470

(mm) FPF20KUG-100 FPF20KU...BE(R)120 FPF20KGU...B(R)-110 Cut-out

6 Axair Fans UK Ltd 01782 349 430

Plastic Adaptors for ‘FPF’ fan filter units• Suitable for all Fandis fan filter kits• Available in 3 sizes (12, 15 and 20)• Allows the filter to sit 23 to 25mm outside the enclosure• IP54 rating• Fixation to the panel by screws• Available in RAL 7032 or RAL 7035• Supplied with gasket

Opposite are 2 sketches representing the fan filter unit FPF type. A is fitted on an enclosure without a spacer. B shows an FPF fitted with a spacer (pictured in blue).

ApplicationA B

FPFA12 FPFA15 FPFA20

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

‘GF’ Series Fan Filter Units• Designed for thicker walled enclosures, including GRP• Plate thickness 8mm up to 16mm• Revolutionary assembly system with jacks• Hinged louver for quick media access• Available in 3 sizes (12, 15 & 20)• IP54 protection• Filter class G3

[email protected] 7

Roof Units‘T’ Series Roof Units• For warm extraction from the top of enclosures• Fitter with backward curved motorised impellers• Can be fitted with FPF for maximum efficiency • Steel casing

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CT19R115B 115 50 71 820

550 500(*) 375 59 5.8-20~+60

T19R230B 230 50 58 260T22R115B 115 50 150 1380

800 700(*) 520 70 6.3T22R230B 230 50 158 690*Kit airflow when used in conjunction with exhaust filter reference FPF20KRG

• Adhesive sealing gasket supplied• IP43 protection• Available in RAL 7032 or RAL 7035• Suitable for operation at 60Hz

• For warm extraction from the top of enclosures• Fitter with backward curved motorised impellers• Can be fitted with FPF for maximum efficiency • Aluminium & plastic (ABS/PC) casing

• Permanent sealing gasket supplied• IP23 or IP54 protection• Available in RAL 7035• Suitable for operation at 60Hz

‘TP’ Series Roof Units

Prot

ectio

n

Volta

ge

Freq

uenc

y

Inpu

tPo

wer

Curr

ent

Max

Airfl

ow(P

oint

1)

Max

Airfl

ow(P

oint

2)

Max

Pres

sure

Soun

d Le

vel

Wei

ght

Tem

p Ra

nge

Reference V Hz W mA m³/h m³/h Pa dB(A) Kg ⁰CTP19U115B

23115 50 78 680

530 480 330 59 2.00-10~+60

TP19U230B 203 50 78 340TP19U230B54 54 230 50 80 350 430 390 320 59 2.10TP19U115B54 54 115 50 61 586 430 390 320 589 2.10

8 Axair Fans UK Ltd 01782 349 430

Thermostats• Bimetallic sensor thermostats• Normally closed (for heaters) of Normally open (for fans or alarm)• Change-over version (for both heaters and fans)• Narrow switch• Control ranger -10⁰C to +80⁰C• Innovative fixing system for 3 sizes DIN rail (15, 32 & 35) (35 only for changeover version)• Standard colour RAL 7035• Accuracy ± 3⁰C

Reference Type Rated Voltage Dimensions Setting Temperature Range

Differential(Referred set point)

Protection Level

(Vac) 50/60Hz (mm) (⁰C) (⁰C) IP

TRT-10A230V-NO Normally Open 110-250 68x29x45 -10~+80 +4 if A <5 ; +7 if A > 5 20

TRT-10A230-NC Normally Closed 110-250 68x29x45 -10~+80 -3ffK 20

TRT-230V-S01 Change-over 230 67x50x38 +5~+60 1 (with thermal retroaction) 30

Hygrostats• Mechanical Hygrostat• Changeover type - Normally open or normally closed• Can be used to operate heater or fan• 35mm DIN rail mounting• Wide humidity ranger (35 to 100%)• Standard colour RAL 7035

Reference Rated Voltage Dimensions Setting Range Differential(Referred set point)

Operating ambienttemperature

Protection Level

(Vac) 50/60Hz (mm) (%RH) (%RH) (⁰C) IP

IGR35F 120-250 93.5x54x52 10~90 5 +10 ... +60 20

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Steel Covers• Accessory compatible with ‘FPF’ and ‘FF’ series• Suitable for outdoor applications or food processing environment• Stainless steel construction• Permanent gasket included

(mm) SSC-08 SSC-12 SSC-13 SSC-15 SSC-20A 156 191 241 288 356B 161 195 246 293 361C 41.5 41.5 41.5 41.5 41.5D 39.5 39.5 39.5 39.5 39.5

[email protected] 9

Heaters• Self regulating PTC element• Black anodised aluminium• Power range 45 to 150Wa• 35mm DIN rail mounting• High power versions available on request (250 & 450Wa)

Reference Dimensions Connection Heating Power Absorbed Current

External Voltage

Internal Heat Sink

(mm) (Type) (Wa) (mA) (⁰C) (⁰C)

RACP-15 72x25x47 2 core cable 15 65 70 80

RAC-45 102x61x64 3 core cable (L, N, PE) 45 200 70 90

RAC-60 102x61x64 3 core cable (L, N, PE) 60 260 85 105

RAC-80 152x61x64 3 core cable (L, N, PE) 80 390 90 110

RAC-100 152x61x64 3 core cable (L, N, PE) 100 475 105 130

RACM-45 117x61x64 Terminal Block 45 200 70 90

RACM-60 117x61x64 Terminal Block 60 260 85 105

RACM-80 167x61x64 Terminal Block 80 390 90 110

RACM-100 167x61x64 Terminal Block 100 475 105 130

RACM-150 167x61x64 Terminal Block 150 770 120 155

Door Switches• Can be used to switch light on or cut power off when door opens• Normally open/normally closed snap action• Version with manual reset switch available• Plastic casing• Voltage range 24 to 400Vac 50/60Hz

Document Holder• Convenient accessory for documentation• Suitable for A4 format• Plastic PC/ABS Alloy• Standard colour RAL 7035

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

10 Axair Fans UK Ltd 01782 349 430

Lights & LED Lights

This range of compact lights for enclosures offers the advantage of compact dimensions, efficiency, quick mounting and long lifetime.

Enclosure LightingThis range of compact lights for enclosures offers the advantage of compact dimensions, efficiency, quick mount-ing and long lifetime.

Fluorescent Lights:Traditional compact AC lights, providing a high luminous efficiency with reduced power consumption.

• On/off switch• 115 or 230Volts available• Choice of power : 6, 8, 13, 16, 20, 24 or 30 Watts versions• 2 Profiles available ; 43mm high x 22mm deep or 43mm high x 20mm deep

(length depending on power from 227 up to 914mm long)

Please contact Axair Fans for codes, datasheets, prices & stock availability.

LED Lights:LED technology reduces operating costs and has a low environmental impact. They offer great energy savings with increased lifetime.

• Wide input voltage 85 to 265VAC.• Dual frequency 50 or 60Hz.• Choice of power ; 8, 12 or 16 Watts versions.• 1 profile available 31mm high x 23mm wide - (Length depending on power from 549 up to 1149mm)• Wide range of colour temperature

[email protected] 11

Special Projects & CapabilitiesAxair offer a wide range of fans for a multitude of industrial applications. These can be used within control panels when the cooling requirement cannot be achieved by standard door mounted fans. The pictures below highlight some of the applications where we have advised the use of fans that would normally be found in standard Heating, Ventilating & Air Conditioning applications.

Lowfield DriveCentre 500Wolstanton

Newcastle-Under-LymeST5 0UU

Tel: 01782 349430Fax: 01782 349439

Email: [email protected]