Theoretical Study and Experimental Validation of Energetic...
Transcript of Theoretical Study and Experimental Validation of Energetic...
Research ArticleTheoretical Study and Experimental Validation of EnergeticPerformances of Photovoltaic/Thermal Air Collector
Khaled Touafek ,1 Abdelkrim Khelifa,1 Lyes Boutina,1 Ismail Tabet,2 and Salim Haddad2
1Unité de Recherche Appliquée en Energies Renouvelables (URAER), Centre de Développement des Energies Renouvelables (CDER),47133 Ghardaïa, Algeria2Université de Skikda, Algeria
Correspondence should be addressed to Khaled Touafek; [email protected]
Received 12 June 2018; Revised 13 September 2018; Accepted 8 October 2018; Published 19 December 2018
Academic Editor: Giulia Grancini
Copyright © 2018 Khaled Touafek et al. This is an open access article distributed under the Creative Commons Attribution License,which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This work undertakes both simulation and experimental studies of a new design of a photovoltaic thermal solar air collector(PV/T). In order to improve the thermal and electrical performances for a specific application, the analytical expressions forthermal parameters and efficiency are derived by developing an energy balance equation for each component of the PV/T aircollector. This type of hybrid collector can be applied in the facades of buildings. The electricity and heat produced will satisfythe energy needs of the buildings, while ensuring an aesthetic view of its facades. A typical prototype was designed, constructed,and implemented in the applied research unit on renewable energies in Ghardaia, situated in the south of Algeria. This regionhas semiarid characteristics. Results obtained by an experimental test are presented and compared to those predicted throughsimulation. Results include the temperature of each component of the PV/T collector and air temperature at the inlet and outletof the channel. It has been found that the theoretical results predicted by the developed mathematical model, for instance, outlettemperature, agree with those found through experimental work.
1. Introduction
Hybrid photovoltaic thermal (PV/T) collectors convert solarenergy both into electrical and thermal energy. This conver-sion allows firstly the cooling of the solar cells and secondlythe exploitation of the resulting heat energy to heat wateror space. Applications of hybrid collectors in habitationsare beneficial from a space-saving perspective. In fact, insteadof separately using photovoltaic modules for electricity andsolar thermal energy for heat, hybrid collectors are used forthe same surface. In the literature, there are several studieson hybrid sensors applied in the habitat [1–5]. The mostimportant thing in air hybrid sensors is to have the highestair outlet temperature compared to the input air tempera-ture. To have that, several techniques are possible. They canbe classified globally in two techniques. The first concernsthe use of new coolant materials or the use of phase changematerials [6–8]. The second technique is the design of theabsorber [9–11]. In this article we are interested in the secondtechnique of optimization of the absorber.
Work on hybrid collectors has been carried out in recentyears [12–15].
Farshchimonfared et al. [16] studied a hybrid PV/T aircollector related to an air distribution system. The aim wasto optimize the channel depth. He found that increases inoptimum depth were related to an increase of the collectorarea. The integration of photovoltaic thermal solar collectorsin a building is increasingly becoming an option of firstchoice. A photovoltaic/thermal integrated collector in abuilding is able to generate higher energy output per collectorunit area compared to conventional solar panels. A hybridPV/T offers the same advantages as a photovoltaic PV collec-tor, but in addition, it offers a look that is more aestheticthan side-by-side photovoltaic modules and solar thermalcollectors and generally produces more energy for the samesurface area [17]. A PV/T air collector integrated to build-ings can be an outer layer that creates a building envelopewhich is double layered. Due to the heat source-generatedsound, their thermal characteristic is different from that ofthe usual wall [18].
HindawiInternational Journal of PhotoenergyVolume 2018, Article ID 2794068, 10 pageshttps://doi.org/10.1155/2018/2794068
In this paper, numerical simulation and experimentalvalidation of a photovoltaic thermal PV/T solar air collectorare conducted. The application of this sensor is conductedin a semiarid climate in the south of Algeria where the veryhigh temperature negatively affects the efficiency of solarcells. The evacuation of the solar cells’ heat causes their cool-ing which allows the photovoltaic sensor to perform well.The modeling of the heat transfer in the PV/T air collectoris performed to 1D for a transitional regime according to anode approach. A numerical code was developed and usedto analyze the thermal behavior as well as the thermal, electri-cal, and global electrical efficiency. Then, an experimentalprototype of the PV/T air collector was set up. The PV/Tair collector temperatures, as well as air inlet and outlet tem-peratures, were measured over a period of a day during themonth of June and November and were compared withPV/T air collector model predictions.
2. Theoretical Study
The designed photovoltaic/thermal air collector studied inthis work is shown in Figure 1. The PV/T air collector is com-posed of a photovoltaic module which consists of arrays ofmonocrystalline circular silicon cells covered with highlytransmitting glass. These cell arrays are interposed on anadhesive layer made of Tedlar having good thermal conduc-tivity and poor electrical conductivity. The photovoltaicmodule is to be mounted on a metal plate painted in blackto increase the absorption of the incident solar radiation fall-ing upon an absorbing plate equipped with rectangular finswhich serve as channels for air circulation. The circulationof the air in the fins collects the generated heat, and a usefulamount of thermal energy is extracted by removing hot airfrom one end of the duct leaving the cold fluid to enter at
the other end. The bottom of the sheath is covered with goodinsulation to minimize heat loss to the ambient temperature.
The thermal energy balance equations for the differentnodes of the system is shown in Figure 1.
The heat balance which describes the thermal behavior ofthe PV/T air collector can be written in the form of first orderordinary differential equations and are given for the follow-ing essential elements of the hybrid PV/T air collector:
(1) For glass
MgcgdTg
dt= qg t − hrgsAg Tg − Ts
− hcgaAg Tg − Ta
− U1 + hrgc Ag Tg − Tc ,
1
where
qg t = αgIg t Ag,
U1 =1hcdg
+1hcdc
−1 2
(2) For solar cells
MccpcdTc
dt= qc t − hcdted + hrct Ac Tc − T ted
+ U1 + hrgc Ac Tg − Tc ,3
Tg
Tc
TTed
Tp
Tb
Tin
r1/hgs
g1/hcd
c1/hcd
cd1/hted
p1/hcd
c1/hpf
c1/hbf
b1/hcd
cd1/hin
r1/hina
c1/hga
r1/hgc
1/hct
r1/htp
r1/hpb
r1/hbin
c1/hina
Tf
r
Figure 1: Photovoltaic thermal air collector.
2 International Journal of Photoenergy
where
qc t = τgαc 1 − ηpv Ig t Ac 4
The solar cell efficiency depends on the cell tempera-ture and is given by [19]
ηpv = ηref 1 − 0 0045 Tc − 25 , 5
where ηref is the reference efficiency of a solar cellat a solar irradiance of 1000Wm−2 and temperatureT ref =25
°C.
In this work, ηref = 10%.
(3) For Tedlar layer
MtedcpteddT teddt
= hcdted + hrct At Tc − T ted
− hrtp + hcdp RtpAt T ted − Tp ,6
where
Rtp =Atp
Ac7
(4) For upper plate with fins
MpcppdTp
dt= − hcdp + hrrtp ApRtp Tp − T ted
− hcpf Apηp Tp − T f − hrpbApRbp Tp − Tb ,8
where ηp is the total efficiency of the absorbing upperplate end and ηf is the fin efficiency [1, 20].
ηf =tanh mhf
λf δf,
m =2hfλf δf
1/2
,
ηp =Ac + Af inηf
Abp,
Rbp =Abp
Ac
9
(5) For fluid in the fins
Mf cpfdT fdt
= −cpf mdT f
wdx− hcpf Af Rbpηp T f − Tp
− hcbf Af T f − Tb
10
(6) For lower plate
MbcpbdTb
dt= hcbf Ab T f − Tb − hrpbAbRbp Tb − Tp
− hrbin +U2 Ab Tb − T in ,11
where
U2 =1hcdin
+1hcdb
−1
12
(7) For insulation
MincpindT indt
= −hrinaAin T in − Ts − hcinaAin T in − Ta
− hrbin +U4 Ain T in − Tb
+ Ain Tb − T in
13
The temporal variation of the components of the collec-tor of heat is low, thus mcpdT /dt can be ignored. We cansafely assume a quasistationary operation of the collector.This simplification of the equation suggests that only solarradiation has a significant effect.
By eliminating Tp and Tb, (11) becomes
dT f
dx+ C1T f x = C2 14
If C1 and C2 are constants obtained from the performedalgebraic calculations, the solution of the equation is
T f x =C2A1
+ T f i −C2C1
e−C1x, 15
and the outlet temperature of the air is
T f out =C2C1
+ T f i −C2C1
e−C1l 16
In the above equations, radiation and convective heattransfer coefficients are calculated using the relationships asreported in [21–23].
The wind convection heat-transfer coefficient hci−a for theair flowing over the outside surface depends primarily on thewind velocity v and is defined as
hci−a = 5 7 + 3 8v 17
The radiation heat transfer coefficient between the glasscover and the sky is given by the following relationship:
hrg−a = εgσ T2g + T2
s Tg + Ts 18
3International Journal of Photoenergy
The equivalent sky temperature is calculated by thefollowing simple correlation equation:
Ts = Ta − 6 19
The radiation heat transfer coefficient between the glasscover and the PV panel is given by the following relationship:
hrg−c = σ T2g + T2
c Tg + Tc1εg
+1εc
− 1 20
The radiation heat transfer coefficient between thePV panel and the Tedlar layer is given by the followingrelationship:
hrc−ted = σ T2c + T2
ted Tc + T ted1εc
+1εted
− 1
21
The radiation heat transfer coefficient between theupper plate and the Tedlar layer is given by the followingrelationship:
hrted−p = σ T2ted + T2
p T ted + Tp1εp
+1εted
− 1
22
The radiation heat transfer coefficient between theupper plate and the lower plate is given by the followingrelationship:
hrb−p = σ T2b + T2
p Tb + Tp1εp
+1εb
− 1 23
The radiation heat transfer coefficient between thelower plate and the insulation is given by the followingrelationship:
hrb−in = σ T2b + T2
in Tb + T in1εin
+1εb
− 1 24
The conduction heat transfer coefficient is given by thefollowing relationship:
hcd =λ
e25
The convection heat transfer coefficient of the fluid isgiven by the following relationship:
hc =λ
Dh0 0158 Re0 8
+ 0 00181 Re + 2 92 exp −0 0379x
Dh,
26
where Re is the Reynolds number
Re =ρDhvμ
, 27
where Dh is the hydraulic diameter.For the rectangular channel
Dh =2 × h ×wh +w
28
The thermal efficiency of photovoltaic solar collector iscalculated by the following relationship [24, 25]:
ηth =Qu
AcIt=mcpf To − Ti dt
Ac Itdt29
The global efficiency of the photovoltaic thermal col-lector is defined as the sum of all thermal efficiency andelectrical efficiency:
ηt = ηth + ηpv 30
3. Numerical Simulation
It is obvious from the theoretical model given above that anumerical solution can be calculated for the temperaturesTg, Tc, Tp, Tb, T in, and T f as most of the heat transfer coef-ficients are functions of these temperatures. Therefore, aniterative numerical method based on Runge-Kutta methodis used. Indeed, a program was written in Fortran 90 inorder to find the values of the temperatures of the PV/Tair collector, as well as the values of the thermal and electricalefficiency. This program is summarized by the flowchart pre-sented in Figure 2.
Furthermore, the solar PV/T air collector dimensionsand properties of working fluids, as well as the operatingconditions, are also needed. System properties and operatingconditions which are employed in this study are tabulated inTable 1. The following physical properties of air are assumedto vary linearly with temperature owing to the low tempera-ture range that can be encountered [20, 23]:
(1) Dynamic viscosity
μair = 0 0146T + 1 8343 10−5 31
(2) Density
ρair = 1 1774 − 0 00359 × T − 27 32
(3) Thermal conductivity
λair = 0 02624 + 0 0000758 × T − 27 33
4 International Journal of Photoenergy
(4) Specific heat
cpair = 1 0057 + 0 00066 × T − 27 × 1009 34
Figure 3 presents the hourly temperature variation ofessential elements of the hybrid PV/T air collector (glasscover, solar cell, layer in Tedlar, upper absorber plate, lowerabsorber plate, and insulation). It can be seen from this fig-ure that all temperatures take maximum values in an intervalof time ranging between 10 and 14 hours when the solarintensity is also maximal.
Equation (17) was used to calculate the outlet tempera-ture of the hybrid PV/T air collector. The adopted mass flowrate values are equal to 0.01 kg/s, 0.02 kg/s, and 0.04 kg/s.Figure 4 displays the hourly variation of the fluid temper-ature at the outlet for different mass flow rates. It can beobserved from this figure that maximal temperaturesoccurred at 43°C, 38.5°C, and 34°C for the respectivemass flow rates of 0.01 kg/s, 0.02 kg/s, and 0.04 kg/s. Itcan be inferred that these temperatures vary with solarradiation intensity.
Figure 5 displays the influence of the channel length onthe outlet air temperature at constant channel width andmass flow rate being equal to 0.04 kg/s. It is observed thatthe outlet air temperature increases with an increase in thechannel length. The increased outlet air temperature is dueto the increase in the heat exchange area which results in adecrease in air velocity; hence, a low heat transfer coefficientis favorable.
The effect of channel length on thermal, electrical, andglobal efficiency in the case of a fluid with a mass flow rateequal to 0.04 kg/s and a channel depth equal to 0.1m isgraphed in Figure 6.
It is observed that the thermal efficiency increases withan increase in channel length, while the electrical outputdecreases with an increase in channel length. The decreasein electrical efficiency is due to the increased PV temperature.
4. Experimental Validation
In Figure 7, a prototype of the hybrid photovoltaic thermalair collector is shown. It has a south orientation and is tiltedat an angle equal to that of the site where it is installed, in thiscase 32.49° in the south of Algeria (Ghardaia) to maximizethe intensity of the solar radiation that falls on it. The PV/Tair collector was made with a monocrystalline PV moduleof 40W, with a 0.5m surface area and an air layer of 0.1mfor collecting hot air. Instrumentation devices are installedto measure the data relating to the thermal and electrical per-formances of the PV/T air collector.
A type k thermoelectric device for measuring tempera-ture is used to measure the temperature of each componentof the PV/T air collector. Each thermocouple is placed onthe surface of each element of the PV/T collector and pho-tovoltaic module. A current and voltage sensor has beeninstalled for measuring the electrical performance. A data-
Table 1: Input parameters for numerical calculations.
Parameter Values Parameter Values
Ai 0. 5× 1 cpc 700
h 0.1 cpted 560
δf × hf × l f 0.001× 0.05× 1 cpp 465
τg 0.90 cpin 880
αg 0.05 ρc 2700
αc 0.95 ρc 2330
λg 1 ρp 7833
λc 148 ρin 15
λted 0.033 ρted 1200
λin 0.041 εg 0.88
λp 54 εc 0.35
σ 5.675e−8 εted 0.35
vw 2 εp 0.95
cpg 840 εin 0.05
Reading parameters andconstants:(i) Geometry of the collector.
(ii) Physical properties of the collector
Initialization temperatures Tgi, Tci Tted, Tpi, Tin, Tfi
Data depending temperatures:(i) Solar radiation.
(ii) Fluid properties.(iii) Heat transfer coefficients.
Calculation of temperature:Tf, Tc, Tted, Tin,Tp, Tb
(i) Definitions/evaluations:(ii) Thermal efficiency
(iii) Electrical efficiency(iv) Global efficiency
Yes
Program
Time loop: t = 1. n
(i) Evaluation of the main elements of matrix
No
i < n
End
Yes, i = i + ΔT
∣Tk+1 − Tk ∣ ≤ 𝜀
Figure 2: Flowchart for the computer program.
5International Journal of Photoenergy
acquisition instrument was also connected to record alldata on the performance of the PV/T collector.
Test standards such as that of ASHRE are used mainly forthe determination of instantaneous thermal efficiency.
Figure 8 displays the hourly variation of the inlet andoutlet air temperatures for the day 15 June 2014. Figure 9displays the variation of temperature elements of the PV/Tair collector.
It is clearly noticed that the temperature of each constit-uent element of the PV/T collector reaches it maximum valueat noon of the day. This is obviously due to the considerableamount of solar radiation incident on the PV/T at this time,
which results in a high-rate absorption of solar radiation bythe PV/T collector. However, it should be noted that each ele-ment reaches its maximum value depending on its location inthe system and its physical characteristics. The temperaturesof the front part of the PV/T collector and the upper platehave higher values when compared to the other elements ofthe PV/T collector. The temperature reaches 60°C at noonof the day for the front of the collector and 50°C for the upperplate, while the temperature of the other components do notexceed 45°C in the same period.
We notice that a temperature difference in the rangeof about 9°C is achieved between the inlet and outlet duringthe time interval ranging between 10 and 14 hours. This isexplained as follows. Because of the increase in the tempera-ture of the upper plate that is bonded to the PV module,
52
48
44
40
36
32
28
24
8 10 12 14Time (hour)
Tem
pera
ture
(°C)
16 18
TgTcTted
TpTbTin
Figure 3: Hourly variation of the PV/T air collector elementtemperature.
44
42
40
38
36
34
32
30
28
26
248 10 12 14 16 18
Mf = 0.01 kg s−1
Mf = 0.02 kg s−1
Mf = 0.04 kg s−1
Time (hour)
Tem
pera
ture
(°C)
Figure 4: Hourly variation of the temperature of the fluid.
36
34
32
30
28
26
24
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2Length (m)
Tem
pera
ture
(°C)
Tf
Figure 5: Variation of the fluid temperature in the PV/T aircollector.
100
80
60
40
20
0
0.0 0.1 0.2 0.3 0.4 0.5 0.6Lenght (m)
Effici
ency
(%)
0.7 0.8 0.9 1.0 1.1 1.2
𝜂th
𝜂t
𝜂pv
Figure 6: Variation of the efficiency of the PV/T air collector.
6 International Journal of Photoenergy
the upper plate absorbs the heat generated by the PVmodule. When the air flows naturally through the channel,a convective exchange occurs between the lower and upperplates with air, and the air takes the heat generated by thetwo plates which increases their temperature at the outletof PV/T air collector.
Figure 10 shows the current-voltage characteristic curvesobtained by the experimental tests in the morning and eve-ning for the two collectors, that is, the photovoltaic moduleand the hybrid PV/T air collector. The results showed thatfor the same surface of the PV and PV/T collector, there isan increase of 7 to 30% of the current intensity of the hybridPV/T relative to the photovoltaic module.
In Figure 11, the comparison between the resultsobtained by experimental numerical modeling of the airtemperature at the outlet of the PV/T air collector is pre-sented. Polynomial interpolation is implemented to approxi-mate the experimental results. The approximation curve isexpressed by (35), in the local time (TL) between 8 hours
and 17 hours and at the temperature between 25°C and40°C. It is given by
T f out exp = −659 03457 + 195 48251TL− 20 32914TL2 + 0 94632TL3
− 0 01688TL435
The coefficient of determination (R2) is the key param-eter which serves as the basis of comparison between thesimulated and experimental results of the fluid outlet temper-atures. The correlation coefficient (R2) has been evaluated byusing the following expression [25]:
R2 = 1 −∑k
i T f out−Exp − T f out−Theo2
∑ki T f out−Exp − T f out−mav
2 36
Data acquisitionPVT air collector
PV module
Figure 7: Photo of the experimental prototype.
9 10 11 12 13 14 15 16 17 18 19
27
30
33
36
39
42
4515-06-2014
Tem
pera
ture
(°C)
Time (Hour)
Tf_outTf_inl
Figure 8: Hourly variations of the inlet and outlet air temperaturesof the PV/T collector.
9 10 11 12 13 14 15 16 17 18 1920
25
30
35
40
45
50
55
60 15-06-2014
Tem
pera
ture
(°C)
Time (Hour)
Tp_expTp_exp
Tg_expTin_exp
Figure 9: Hourly variation of the temperature elements of thePV/T.
7International Journal of Photoenergy
The correlation coefficient (R2) is an indicator for judgingthe quality of a linear regression, either single or multiple, at avalue between 0 and 1. We found that the R2 value is equal to0.7, in we find this value acceptable.
We did not study the effect of pressure on electricaland thermal efficiencies. We consider that the temperatureis too low for there to be an influence of the pressureon the heat transfer and consequently on the efficiency ofthe collector.
5. Conclusion
In this work, a hybrid PV/T system was investigated,modeled, constructed, and tested. It was found that by com-bining a PV module with an air collector, the electrical per-formances are noticeably enhanced. The resulting thermal
energy can be exploited to achieve thermal comfort in abuilding. A mathematical model based on energy balancewas developed. Simulation results of this model obtained byusing FORTRAN 90 programming language are plotted.The temperatures in the inlet and outlet are monitored andrecorded. It was found that the temperature at outlet is higherthan the temperature at the inlet, which suggests that a heatexchange has taken place and this is the reason for theimprovement of the PV module performances.
The results found through simulation were compared tothose found experimentally. Their comparison does showgood agreement. This agreement is more pronounced in thecase of the inlet and outlet fluid temperatures.
In conclusion, the combination of the PV module withthe thermal collector would enhance the electrical perfor-mances of the PV module and the resulting thermal energycan be used for other purposes, for instance, to achievethermal comfort in a building when this combination is wallintegrated. In other applications, when water is used insteadof air, the heated water can be used for sanitary purposes.
As a future work to further improve the performances ofsuch systems, the PV module is to be replaced by a high-efficiency PV module and a reflector is used to concentratesolar radiation upon it.
Nomenclature
A: Surface (m2)Cp: Specific heat (J kg−1 k−1)Dh: Hydraulic diameter (m)e: Thickness (m)hc: Convective-exchange coefficient (Wm−2 k−1)hr : Radiative-exchange coefficient (Wm−2 k−1)h: Channel depth (m)I: Solar intensity (Wm−2)l: Length of the collector (m)m: Mass flow (kg·s−1)M: Mass (kg)n: Number of finsR: Area ratioRe: Reynolds numberq: Heat flow (W)P: Power (W)t: Time (s)Tl: Local time (hour)T : Temperature (°C)v: Speed (m s−1)w: Width of the collector (m)U : Heat transfer coefficient (Wm−2 k−1)x: Distance (m).
Greek Symbols
α: Absorbanceδ: Thickness of fin (m)ε: Emissivityη: Efficiencyλ: Thermal conductivity (Wm−1 k−1)ρ: Density (kgm−3)
0 2 4 6 8 10 12 14 16 18 200.0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
Voltage (V)
Curr
ent (
A)
Hour 12
PVPV/T
Figure 10: Current-voltage characteristic curves of the PV/T aircollector and PV module.
8 9 11 12 13 14 15 16 17
21
24
27
30
33
36
39
42
45
48
Tem
pera
ture
(°C)
Time (hour)
Equation
y = intercept + B1⁎x^1 + B2⁎x^2+ B3⁎x^3 + B4⁎x
^4
Weight No weightingResidual sum of squares
547,83128
Adj. R-square 0.88076
B
Value Standard errorIntercept −659,03457 143,37995
B1 195,48251 47,99109B2 −20,32914 5,91116B3 0,94632 0,31782B4 −0,01688 0,0063
Tfout_Exp
Polynomial fitTfout_�e
Figure 11: Validation of the mathematical model.
8 International Journal of Photoenergy
μ: Dynamic viscosity (kg·m−1 s−1)σ: Stefane-Boltzmann constant (Wm−2 K−4)τ: Transmittanceζ: Convergence criterion.
Subscripts and Abbreviations
a: Ambientb: Lower platebp: Bottom surface of absorber platec: Solar cellf : Fluidinl: Inletg: Glass coverin: Insulatorp: Upper platepv: Electricout: Outlets: Skyted: TedlarExp: Experimentalt: Totalth: Thermaltp: Top surface of absorber plateTheo: Theorymav: Mean value.
Data Availability
All data used in this work is included in the paper.
Conflicts of Interest
The authors declare that there is no conflict of interestregarding the publication of this paper. This research wasperformed as part of the requirements during the employ-ment of the authors at the Unit of Applied Research inRenewable Energy (URAER)
References
[1] Z. B. Liu, L. Zhang, Y. Q. Luo, Y. L. Zhang, and Z. H. Wu,“Performance evaluation of a photovoltaic thermal-compoundthermoelectric ventilator system,” Energy and Buildings,vol. 167, pp. 23–29, 2018.
[2] D. Gürlich, A. Dalibard, and U. Eicker, “Photovoltaic-thermalhybrid collector performance for direct trigeneration in aEuropean building retrofit case study,” Energy and Buildings,vol. 152, pp. 701–717, 2017.
[3] M. Fiorentini, P. Cooper, and Z. Ma, “Development and opti-mization of an innovative HVAC system with integrated PVTand PCM thermal storage for a net-zero energy retrofittedhouse,” Energy and Buildings, vol. 94, pp. 21–32, 2015.
[4] C. Lamnatou and D. Chemisana, “Photovoltaic/thermal (PVT)systems: a review with emphasis on environmental issues,”Renewable Energy, vol. 105, pp. 270–287, 2017.
[5] M. Piratheepan and T. N. Anderson, “Performance of a build-ing integrated photovoltaic/thermal concentrator, for facadeapplications,” Solar Energy, vol. 153, pp. 562–573, 2017.
[6] M. Song, F. Niu, N. Mao, Y. Hu, and S. Deng, “Review on build-ing energy performance improvement using phase changematerials,” Energy and Buildings, vol. 158, pp. 776–793, 2018.
[7] D. Su, Y. Jia, Y. Lin, and G. Fang, “Maximizing the energyoutput of a photovoltaic–thermal solar collector incorporat-ing phase change materials,” Energy and Buildings, vol. 153,pp. 382–391, 2017.
[8] W. Lin, Z. Ma, P. Cooper, M. I. Sohel, and L. Yang, “Thermalperformance investigation and optimization of buildings withintegrated phase change materials and solar photovoltaic ther-mal collectors,” Energy and Buildings, vol. 116, pp. 562–573,2016.
[9] K. Touafek, M. Haddadi, and A. Malek, “Design and modelingof a photovoltaic thermal collector for domestic air heatingand electricity production,” Energy and Buildings, vol. 59,pp. 21–28, 2013.
[10] M. Alobaid, B. Hughes, J. K. Calautit, D. O’Connor, andA. Heyes, “A review of solar driven absorption cooling withphotovoltaic thermal systems,” Renewable and SustainableEnergy Reviews, vol. 76, pp. 728–742, 2017.
[11] M. Hosseinzadeh, A. Salari, M. Sardarabadi, andM. Passandideh-Fard, “Optimization and parametric analysisof a nanofluid based photovoltaic thermal system: 3D numer-ical model with experimental validation,” Energy Conversionand Management, vol. 160, no. 15, pp. 93–108, 2018.
[12] J. F. Chen, L. Zhang, and Y. J. Dai, “Performance analysis andmulti-objective optimization of a hybrid photovoltaic/thermalcollector for domestic hot water application,” Energy, vol. 143,pp. 500–516, 2018.
[13] L. Sahota and G. N. Tiwari, “Review on series connected pho-tovoltaic thermal (PVT) systems: analytical and experimentalstudies,” Solar Energy, vol. 150, pp. 96–127, 2017.
[14] E. Sakellariou and P. Axaopoulos, “Simulation and experimen-tal performance analysis of a modified PV panel to a PVT col-lector,” Solar Energy, vol. 155, pp. 715–726, 2017.
[15] D. B. Singh, “Improving the performance of single slope solarstill by including N identical PVT collectors,” Applied ThermalEngineering, vol. 131, pp. 167–179, 2018.
[16] M. Farshchimonfared, J. I. Bilbao, and A. B. Sproul, “Channeldepth, air mass flow rate and air distribution duct diameteroptimization of photovoltaic thermal (PV/T) air collectorslinked to residential buildings,” Renewable Energy, vol. 76,pp. 27–35, 2015.
[17] V. Delisle and M. Kummert, “A novel approach to comparebuilding-integrated photovoltaics/thermal air collectors toside-by-side PV modules and solar thermal collectors,” SolarEnergy, vol. 100, pp. 50–65, 2014.
[18] J.-H. Kim and J.-T. Kim, “A simulation study of air-typebuilding-integrated photovoltaic-thermal system,” Energy Pro-cedia, vol. 30, pp. 1016–1024, 2012.
[19] A. K. Athienitis, J. Bambara, B. O’Neill, and J. Faille, “A proto-type photovoltaic/thermal system integrated with transpiredcollector,” Solar Energy, vol. 85, no. 1, pp. 139–153, 2011.
[20] M. Gholampour and M. Ameri, “Energy and exergy study ofeffective parameters on performance of photovoltaic/thermalnatural air collectors,” Journal of Solar Energy Engineering,vol. 136, no. 3, article 031001, 2014.
[21] L. M. Candanedo, A. Athienitis, and K.-W. Park, “Convectiveheat transfer coefficients in a building integrated photovoltaic/thermal system,” Journal of Solar Energy Engineering, vol. 133,no. 2, article 021002, 2011.
9International Journal of Photoenergy
[22] J. A. Duffie and W. A. Beckman, Solar Engineering of ThermalProcesses, JohnWiley & Sons, New York, NY, USA, 2nd edi-tion, 1991.
[23] E. M. Ali Alfegi, K. Sopian, M. Y. H. Othman, and B. B. Yatim,“Transient mathematical model of both side single pass photo-voltaic thermal air collector,” ARPN Journal of Engineeringand Applied Sciences, vol. 2, p. 5, 2007.
[24] K. Touafek, M. Haddadi, and A. Malek, “Experimental studyon a new hybrid photovoltaic thermal collector,” Applied SolarEnergy, vol. 45, no. 3, pp. 181–186, 2009.
[25] I. Tabet, K. Touafek, N. Bellel, N. Bouarroudj, A. Khelifa, andM. Adouane, “Optimization of angle of inclination of thehybrid photovoltaic-thermal solar collector using particleswarm optimization algorithm,” Journal of Renewable andSustainable Energy, vol. 6, no. 5, article 053116, 2014.
10 International Journal of Photoenergy
TribologyAdvances in
Hindawiwww.hindawi.com Volume 2018
Hindawiwww.hindawi.com Volume 2018
International Journal ofInternational Journal ofPhotoenergy
Hindawiwww.hindawi.com Volume 2018
Journal of
Chemistry
Hindawiwww.hindawi.com Volume 2018
Advances inPhysical Chemistry
Hindawiwww.hindawi.com
Analytical Methods in Chemistry
Journal of
Volume 2018
Bioinorganic Chemistry and ApplicationsHindawiwww.hindawi.com Volume 2018
SpectroscopyInternational Journal of
Hindawiwww.hindawi.com Volume 2018
Hindawi Publishing Corporation http://www.hindawi.com Volume 2013Hindawiwww.hindawi.com
The Scientific World Journal
Volume 2018
Medicinal ChemistryInternational Journal of
Hindawiwww.hindawi.com Volume 2018
NanotechnologyHindawiwww.hindawi.com Volume 2018
Journal of
Applied ChemistryJournal of
Hindawiwww.hindawi.com Volume 2018
Hindawiwww.hindawi.com Volume 2018
Biochemistry Research International
Hindawiwww.hindawi.com Volume 2018
Enzyme Research
Hindawiwww.hindawi.com Volume 2018
Journal of
SpectroscopyAnalytical ChemistryInternational Journal of
Hindawiwww.hindawi.com Volume 2018
MaterialsJournal of
Hindawiwww.hindawi.com Volume 2018
Hindawiwww.hindawi.com Volume 2018
BioMed Research International Electrochemistry
International Journal of
Hindawiwww.hindawi.com Volume 2018
Na
nom
ate
ria
ls
Hindawiwww.hindawi.com Volume 2018
Journal ofNanomaterials
Submit your manuscripts atwww.hindawi.com