The user - 보일러는 역시!귀뚜라미krb.co.kr/english/products/Medimum Size Gas Boiler (user...

34

Transcript of The user - 보일러는 역시!귀뚜라미krb.co.kr/english/products/Medimum Size Gas Boiler (user...

  • The user s manual uses symbols to indicate that caution shouldbe exercised to prevent accidents caused by incorrect operation,

    or damage to the users and their properties. Please read carefully

    and make sure you fully understand the symbols and their mean-

    ings to ensure correct operation of the product. The boiler frame protects theboiler from vibration. Do notuse the frame for movementor transportation.

  • Press the (Home, Reservation, Outing)button until Indoor is displayed onthe window.(Each time you press the [Home, Reservation,

    Outing] button, Home," Reservation, and

    Outing are displayed in turn.)

    Function display Operation lamp

    Up/Down button

    Season selectbuttonReservationsetup button

    Power button

    Function selectbutton (Home,Reservation,Outing)

    The function display window Displays the availability, current tempera-ture, desired temperature, scheduledswitch-on/stop time, burning, SeasonSelection, and self-diagnosis number.

    The Home, Reservation, Outing selection buttonsSelect one of the following: Home, Reservation,or Outing, depending on whether you re homeor not.

    Bath function selection button Toggles the bath function.

    Operation lamp Displays different types of lighting dependingon the current function.

    Up/down buttonChanges the configuration value per function.

    Season selection button (Heating) buttonSets up the heating options.

    Reservation setup buttonSets up scheduled operation and stops time.

    Power button Switches the unit on or off - used forrestarting the boiler after a checkup in caseof failure.(Immediate restarting works up to 3 timesonly, after which 5 minutes of cool downtime is required.)

    Bath functionselection button

    What is "Season Selection"?You can select one of the following preset temperatures per season for the indoor/reserve functions:

    The Up( )/Down( )buttons let youselect the temperature as needed. (The boiler is activated when the desired

    temperature is higher than the current

    temperature.)

    The Season Selection button letsyou select one of the seasonalmodes for appropriate heating. (Summer>Autumn>Spring>Early

    Winter>Winter are selected in turn each

    time you press the Season Selection button)

    Press the sea-son selection

    button to selecta mode

    For the indoor mode (CTR-5700PLUS)

    Tip about the boiler

    Season

    Temperature

    Summer Autumn Spring Early Winter Winter

  • Press the (Home, Reservation, Outing)button until Reservation is on.

    (The operation lamp turns on at the pre-set time

    and the reservation function starts first.)Example: The boiler will be operate for 20 minutes,

    pause for 2 hours, and then operate for 30 minutes.

    Changing the scheduled operation time

    How to Use Reservation Function

    Making better use of the Reservation functionSet the operation and pause time of the boiler appropriately so that you can save on fuel costs

    due to unnecessary operation.

    (Determine the time as needed, depending on the season and heating preferences of your home)

    Press the Reservation button again.When the Reservation time flickers, pressthe Up( )/Down( ) buttons as needed.

    If you re done with scheduling heating in this state, the

    scheduled stop time will be activated first.

    Press the Reservation button When the time (minute) flickers, press theUp( )/Down( ) buttons as needed.

    If you re done with scheduling heating in this state, the

    scheduled stop time will be activated first.

    If there s no button operation for a certain length of time, the timeconfiguration will be halted and the boiler will return to its originalmode before Scheduling Heating

    What is "freeze protection"?

    Press the (Home, Reservation,Outing) button until Outing is on

    (The Outing mode maintains the minimum

    indoor temperature to prevent damage

    from the boiler freezing and bursting.)

    How to Use the Outing function

    Tip about the boiler

    The freeze protection function maintains the boiler system, floor heating pipeline, and

    the connecting lines at the appropriate temperature to prevent damage from freezing.

    When you leave your house in the cold seasons, the power plug of the boiler must be

    connected to the receptacle and the fuel (gas) valve must be open.

    During severe winter weather, set the temperature at around 10-15 to prevent the unit from freezing.

    In the situation that falls under any of the instances below, the freeze protection function will not work:

    Power failure or boiler power cord is unplugged.

    Fuel (gas) supply valve is closed, or fuel supply is cut off.The water feed pipe oran other exposed pipe is not properly heat insulated.

    Tip about the boiler

  • How to Use the Bath function How to use the Temperature Customizing Function

    If you plan to use a lot of hot water, press theBath button.

    The boiler returns to normal after two andhalf hours after toggling the Bath mode.

    The water pressure should be higher than78-147 (0.8-1.5kgf/ ). If your water pres-sure is higher than recommended, install adecompression device.

    Cautions about the bath function

    How to Use the Temperature Customizing Function

    Be careful of getting burned when using hot water.Hot water may pour out suddenly when you turn on the hot water faucet after toggling the bath function.Pay attention to children, the elderly, or the disabled.The water is not recommended for drinking.The customized temperature function is available when the valve is completely set to hot water whilethe boiler is operating in its heating modeUsing hot water for an extended period of time in the heating mode may result in lukewarm water.Turning the boiler on/off in the Bath mode reverts the boiler to a normal heating mode.

    Press the bath button to toggle the Bath mode Use the Up( )/Down( ) buttons to set the temper-ature as needed. (The available temperature range is 35-60 )Press the (Home, Reservation, Outing) button toreturn to the normal mode.

    What is the Temperature Customizing Function?If you plan to use hot water during one of the Home, Reservation, Outing modes, activate this

    function to set the temperature as needed.

    When you test-operate the boiler, make sure to activate the mode for heat-

    ing stored water as shown below by using the indoor controller. Otherwise,

    hot water will not be hotter than 50 .

    Press the Bath and Reservation buttonssimultaneously, with the power set to"off," to find digits flickering as shown inthe figure.

    Press Up( ) to activate the mode forheating stored water as default mode.

    Press the bath button again to turn the boileron at the default mode.

    Press bothat Once

    Tip about the boiler

    Tip about the boiler

  • The boiler uses the room temperature controller and a controller. The main functionsinclude the room temperature selection and bath function. You may conveniently usethe functions when necessary.

  • Heat return, outlet (A)

    Heat inlet, outlet (A)

    Flue Size ( )

    W x D x H

    Category

    Rated Capacity kcal/h

    Hot Water Supply Output Lit/h

    Heat Transfer Area m2

    Water for Boiler m2

    Boiler Efficiency %

    Max. Operating Pressure Mpa(kgf/cm2)

    Drain(A)

    Outflow, return header (A)

    Flue header (A)

    Boiler Efficiency %

    Category

    Rated Capacity kcal/h

    Hot Water Supply Output kcal/h

    Hot Water Supply Output Lit/h

    Heat Transfer Area m2

    Water for Boiler m2

    Max. Operating Pressure Mpa(kgf/cm2)

    Weight kg

    Power Supply V x ph

  • Medium Size, Gas : KS-50/KR-50, KS-70/KR-70KS-100/KR-100, KS-150/KR-150KS-300/KR-300, KS-300/KR-300KS-400/KR-400, KS-70/KR-70

    Kiturami Medium SizeGas Boiler

    Make sure to keep the user s manual in the vicinity of the boiler, after reading it.

    The user s manual describes the features of the product and the safety requirements.Please read and make sure you fully understand the user s manual before using theproducts to ensure an extended lifecycle.

    User's Manual

    Please read this manual carefully before installing the boiler.

  • C O N T E N T S

    Safety CautionsThe precautions are classified into three categories:

    DANGER, WARNING and CAUTION.

    Hazard or unsafe practices that may result in severe personal injury of death.

    Hazard or unsafe practices that may result in severe personal injury of death.

    To reduce the risk of fire, explosion, electric shock, or personal injury when usingboiler, please refer to the manual carefully.

    CONTENTS 02

    Structure and Name 03

    How to Operate 04

    Precautions for Operation 16

    Daily Inspection 17

    How to Install 18

    Test Operation and Installation 25of the Indoor Thermometer

    Control Circuit Diagram(Mechanical) 27

    Specifications for the Boiler 29

    Troubleshooting 27

    Memorandum 31

    The user s manual uses symbols to indicate that caution should be

    exercised to prevent accidents caused by incorrect operation, or

    damage to the users and their properties. Please read carefully and

    make sure you fully understand the symbols and their meanings to

    ensure correct operation of the product.

    Gas Boiler

    Structure and Major Components

    The hot water inlet/outlet of this model are on the rear side of the boiler.

    C a u t i o n

    The boiler frame protects theboiler from vibration. Do notuse the frame for movementor transportation.

    Danger

    KS, KR (50k-150k)(CTR-5700PLUS)

    Room Temperature Controller

    KS, KR -5~200,000

    Other components included:User instructions and the indoortemperature controller for either theCTR-5700PLUS or CTR-1300

    * The indoor temperature controller formodels with +300k kal/h is sold separately.A commercially available bimetal switch(ON/OFF) can be used too(+220V/8A).

    Control box

    Heating outletAdapter forchimney

    BurnerHeating water collector/Drain

    Completecombustion

    system Base

    Frame

    StiffenerFlame monitoring window

    KS, KR (200k)(CTR-1300)

    DANGER

    WARNING

    CAUTION

  • Press the (Home, Reservation, Outing)button until Indoor is displayed in thewindow.(Each time you press the [Home, Reservation,

    Outing] button, Home," Reservation, and

    Outing are displayed in turn.)

    User instructions & description for the CTR-5700PLUS

    How to use the indoor temperature controllerfor models with 50k - 150k kcal/h capacity.

    Only

    5~1

    5 M

    odel

    Function display Operation lamp

    Up/Down button

    Season selectbuttonReservationsetup button

    Power button

    Function selectbutton (Home,Reservation,Outing)

    The function display window Displays the availability, current tempera-ture, desired temperature, scheduledswitch-on/stop time, burning, SeasonSelection, and self-diagnosis number.

    The Home, Reservation, Outing selection buttonsSelect one of the following: Home, Reservation,or Outing, depending on whether you re homeor not.

    Bath function selection button Toggles the bath function.

    Operation lamp Displays different types of lighting dependingon the current function.

    Up/down buttonChanges the configuration value per function.

    Season selection button (Heating) buttonSets up the heating options.

    Reservation setup buttonSets up scheduled operation and stop time.

    Power button Switches the unit on or off - used forrestarting the boiler after a checkup incase of failure.(Immediate restarting works up to 3 timesonly, after which 5 minutes of cool downtime is required.)

    Bath functionselection button

    What is "Season Selection"?You can select one of the following preset temperatures per season for the indoor/reserve functions:

    The Up( )/Down( )buttons let youselect the temperature as needed. (The boiler is activated when the desired

    temperature is higher than the current

    temperature.)

    The Season Selection button letsyou select one of the seasonalmodes for appropriate heating. (Summer>Autumn>Spring>Early

    Winter>Winter are selected in turn each

    time you press the Season Selection button)

    Press the sea-son selection

    button to selecta mode

    For the indoor mode (CTR-5700PLUS)

    Tip about the boiler

    Season

    Temperature

    Summer Autumn Spring Early Winter Winter

  • Press the (Home, Reservation, Outing)button until Reservation is on.

    (The operation lamp turns on at the pre-set time

    and the reservation function starts first.)Example: The boiler will be operate for 20 minutes,

    pause for 2 hours, and then operate for 30 minutes.

    Changing the scheduled operation time

    How to Use Reservation Function

    Set up theestimated timeafter clicking

    Setting

    Making better use of the Reservation functionSet the operation and pause time of the boiler appropriately so that you can save on fuel costs

    due to unnecessary operation.

    (Determine the time as needed, depending on the season and heating preferences of your home)

    Press the Reservation button again.When the Reservation time flickers, pressthe Up( )/Down( ) buttons as needed.

    If you re done with scheduling heating in this state, the

    scheduled stop time will be activated first.

    Press the Reservation button When the time (minute) flickers, press theUp( )/Down( ) buttons as needed.

    If you re done with scheduling heating in this state, the

    scheduled stop time will be activated first.

    If there s no button operation for a certain length of time, the timeconfiguration will be halted and the boiler will return to its originalmode before Scheduling Heating

    What is "freeze protection"?

    Press the (Home, Reservation,Outing) button until Outing is on

    (The Outing mode maintains the minimum

    indoor temperature to prevent damage

    from the boiler freezing and bursting.)

    How to Use the Outing function

    Tip about the boiler

    The freeze protection function maintains the boiler system, floor heating pipeline, and

    the connecting lines at the appropriate temperature to prevent damage from freezing.

    When you leave your house in the cold seasons, the power plug of the boiler must be

    connected to the receptacle and the fuel (gas) valve must be open.

    During severe winter weather, set the temperature at around 10-15 to prevent the unit from freezing.

    In the situation that falls under any of the instances below, the freeze protection function will not work:

    Power failure or boiler power cord is unplugged.

    Fuel (gas) supply valve is closed, or fuel supply is cut off.The water feed pipe oran other exposed pipe is not properly heat insulated.

    Tip about the boiler

    Only

    5~1

    5 M

    odel

  • How to Use the Bath function How to use the Temperature Customizing Function

    If you plan to use a lot of hot water, press theBath button.

    The boiler returns to normal after two andhalf hours after toggling the Bath mode.

    The water pressure should be higher than78-147 (0.8-1.5kgf/ ). If your water pres-sure is higher than recommended, install adecompression device.

    Cautions about the bath function

    How to Use the Temperature Customizing Function

    Be careful of getting burned when using hot water.Hot water may pour out suddenly when you turn on the hot water faucet after toggling the bath function.Pay attention to children, the elderly, or the disabled.The water is not recommended for drinking.The customized temperature function is available when the valve is completely set to hot water whilethe boiler is operating in its heating modeUsing hot water for an extended period of time in the heating mode may result in lukewarm water.Turning the boiler on/off in the Bath mode reverts the boiler to a normal heating mode.

    Press the bath button to toggle the Bath mode Use the Up( )/Down( ) buttons to set the temper-ature as needed. (The available temperature range is 35-60 )Press the (Home, Reservation, Outing) button toreturn to the normal mode.

    What is the Temperature Customizing Function?If you plan to use hot water during one of the Home, Reservation, Outing modes, activate this

    function to set the temperature as needed.

    When you test-operate the boiler, make sure to activate the mode for heat-

    ing stored water as shown below by using the indoor controller. Otherwise,

    hot water will not be hotter than 50 .

    Press the Bath and Reservation buttonssimultaneously, with the power set to"off," to find digits flickering as shown inthe figure.

    Press Up( ) to activate the mode forheating stored water as default mode.

    Press the bath button again to turn the boileron at the default mode.

    Press bothat Once

    Tip about the boiler

    Tip about the boiler

    Only

    5~1

    5 M

    odel

  • The indoor temperature controller controls the boiler. The major functions include settingthe indoor temperature and bath function, which you can make use of as needed.

    Detailed descriptions & instructions for the CTR-1300

    The indoor temperature controller CTR 1300

    TemperatureKnob

    Operationlamp

    Schedulinglamp

    Indoor temperaturebutton

    Outing setup

    Restart

    Sleep mode

    Bath function

    Reservationsetup knob Checkup lamp

    Check if the Reservation setup knob is set to "Stop" when you want to use the boiler, exceptreservation mode. The CTR-1300 is only for a gas boiler with a +200,000 kcal/h capacity.

    Only

    20

    Mod

    el

  • Only

    5~2

    0 M

    odel

  • The stored water entrance/exit pipes are installed for heating the home & water model only.A strainer (hot water filter) must be installed.In a gas boiler whose capacity is 200,000 or above, if the emission pipe (65A) cannot beinstalled, a safety valve (pressure relief valve, 25A or larger) must be installed.

    waste gas temperature limiter is obligatory for boilers with 200k kcal/h. (If thetemperature difference of waste gas is higher than 300 , the limiter has to be ableto shut off the fuel supply automatically, and should be restarted manually.)

  • 12043020427