The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of...
Transcript of The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of...
![Page 1: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/1.jpg)
The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS
Part 1 – Field and Lab Methods
George Butcher M.Sc.Water Stewardship DivisionMinistry of Environment
Linda Gregory PhDConsultantMill Bay, BC
![Page 2: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/2.jpg)
Ideal Program
• Coordinated / Centralized • Integrated• Consistent• Quality data• Web-based, real-time
![Page 3: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/3.jpg)
BC Situation
• Forest Renewal BC / FIA (Forest Investment Account)
– Community Watersheds– “Results Based” / Professional Reliance
• Past Practise
![Page 4: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/4.jpg)
“the water quality probes and data loggers used in these studies failed to generate usable data due to vandalism, as well as lack of maintenance, lack of calibration and general trouble shooting by field staff.
There is no evidence that the equipment installed was not capable of performing as anticipated”
![Page 5: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/5.jpg)
Present sitesPurpose / Applications• Monitor logging impacts• Develop Water Quality Objectives• Aid in development of watershed plan• Trend monitoring and climate change• Monitor Mountain Pine Beetle impacts• Taste & Odour precursor study• Post wildfire study
![Page 6: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/6.jpg)
Station Design
Validation
Data Management
Field and LaboratoryProcedures
BC Protocol
![Page 7: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/7.jpg)
Station Design
![Page 8: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/8.jpg)
Typical Sensor Lifespans
Temperature 5+ yearsConductivity 5+ yearspH / ORP 1-3 yearsDissolved Oxygen 3-5 yearsTurbidity/ Chlorophyll 5+ yearsISE’s months -1yr
![Page 9: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/9.jpg)
Station Design
Validation
Data Management
Field and LaboratoryProcedures
“3 judgements or premises”
![Page 10: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/10.jpg)
Field and LaboratoryProcedures
Priority #1: Ensure that the sensors are properly serviced
Field Visit
![Page 11: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/11.jpg)
Field and LaboratoryProcedures
Inspect
Clean
Calibrate
Only One Sonde per site
![Page 12: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/12.jpg)
BC Field Conditions - Need for Stable Environment
![Page 13: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/13.jpg)
BC Field Conditions - Need for Stable Environment
![Page 14: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/14.jpg)
STABLE ENVIRONMENT
• Stable temperature• Bench or table• Storage facility for calibration standards and water• Access to water and cleaning facilities• Good lighting
![Page 15: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/15.jpg)
Stable Environment
![Page 16: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/16.jpg)
Recommended Protocol in BC - 1
Clean sensors
Inspect & re-calibrate
sensors
Deployed sonde
(pre-cleaning)
Deployed sonde
(re-deployment)
Deployed Sonde
(post-cleaning)
Move to a stable
environment
Move back to the
field site
Field site
Stable environment
Field site
![Page 17: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/17.jpg)
a fresh sample of stream water is collected
Sonde is transported separately
Stream water used for both measurements
![Page 18: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/18.jpg)
Recommended Protocol in BC - 2
Field site
Stable environment
Field site
Clean sensors
Inspect & calibrate
sensors
Deployed sonde
(pre-cleaning)
Deployed sonde
(re-deployment)
Deployed Sonde
(post-cleaning)
Move to a stable
environment
Move back to the
field site
Fouling + Change in stream water
![Page 19: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/19.jpg)
Recommended Protocol in BC - 3
Field site
Stable environment
Field site
Clean sensors
Inspect & calibrate
sensors
Deployed sonde
(pre-cleaning)
Deployed sonde
(re-deployment)
Deployed Sonde
(post-cleaning)
Move to a stable
environment
Move back to the
field site
Portable sonde Portable sonde
& &Fouling + change in stream water
Change in stream water
Fouling
&
![Page 20: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/20.jpg)
Minimal disturbance of the deployed sonde before cleaning
Deployed sonde
Portable sonde – in 2nd tube
![Page 21: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/21.jpg)
![Page 22: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/22.jpg)
Recommended Protocol in BC – 4 Fouling Calculations
Field site
Stable environment
Field site
Clean sensors
Inspect & calibrate
sensors
Deployed sonde
(pre-cleaning)
Deployed sonde
(re-deployment)
Deployed Sonde
(post-cleaning)
Move to a stable
environment
Move back to the
field site
Portable sonde Portable sonde
D1 D2D1 – D2 = Fouling + Change in Water
P1 – P2 = Change in stream water
Fouling = (D1-D2) - (P1-P2)
&P1 P2
![Page 23: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/23.jpg)
Recommended Protocol in BC - 5
Field site
Stable environment
Field site
Clean sensors
Inspect & calibrate
sensors
Deployed sonde
(pre-cleaning)
Deployed sonde
(re-deployment)
Deployed Sonde
(post-cleaning)
Move to a stable
environment
Move back to the
field site
Portable sonde Portable sondePortable sonde
&
Calibration drift Final check
![Page 24: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/24.jpg)
Potential Limitations
• One Sonde; No replicates
• Data Gaps - Moving to stable environment
![Page 25: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/25.jpg)
Station Design
Validation
Data Management
Field and LaboratoryProcedures
BC Protocol
![Page 26: The Province of British Columbia’s Approach to CONTINUOUS … · 2020. 1. 28. · The Province of British Columbia’s Approach to CONTINUOUS WATER-QUALITY SAMPLING PROGRAMS Part](https://reader031.fdocuments.in/reader031/viewer/2022011916/5fdea3cd9d67921a491f7aeb/html5/thumbnails/26.jpg)
http://ilmbwww.gov.bc.ca/risc/pubs/aquatic/index.htm
BC Protocol Website: