HyCal reconstruction: current situation and future tasks . V. Mochalov, IHEP (Protvino)
The PrimEx HyCal Calorimeter
description
Transcript of The PrimEx HyCal Calorimeter
5/10/2010 1GlueX Col meeting, A. Gasparian
1
The PrimEx HyCal Calorimeter
A. GasparianNC A&T State University, Greensboro, NC
Outline
HyCal calorimeter PbW04 detectors Resolutions Transition region
5/10/2010 2
The PrimEx HyCal Calorimeter
1152 PbWO4 individual crystal detectors (70 x 70 cm2 insertion)
GlueX Col meeting, A. Gasparian
576 Lead Glass detectors
5/10/2010 3
The HYCAL Calorimeter (Crystal part)
GlueX Col meeting, A. Gasparian
Calor-2004, March 30 A. Gasparian 4
PbWO4 Crystal Dimensions
Geometrical size:
20.5 x 20.5 x 180.0 mm3
Tolerances (mm):
20.5 + 0.0 - 0.1 180.0 + 0.3 -0.0 Specified
Measured
Calor-2004, March 30 A. Gasparian 5
PbWO4: Optical Properties
04/21/23 6
PbWO4: Position Resolution vs. Energy
Detector characteristics and resolution have been done in different ways: with secondary electron beam (PS in Hall B); with low intensity tagged photon beam (Hall B tagger)
σ =2.7 mm @ 1. GeV
04/21/23 7
PbWO4: Position Resolution vs. impact coordinate
04/21/23 8
Lead-Glass: Position Resolutionvs. Energy
σ =5.6 mm @ 1. GeV
04/21/23 9
PbWO4: Energy Resolution vs. Energy
σ =2.45% @ 1. GeV
04/21/23 10
Lead-Glass: Energy Resolution vs. Energy
σ =5.7% @ 1. GeV
04/21/23 11
Transition Region: PbWO4 - Lead-Glass
04/21/23 12
Transition Region: PbWO4 - Lead-GlassReconstructed Coordinate
04/21/23 13
Transition Region: PbWO4 - Lead-GlassReconstructed Coordinate (Eγ = 5.2 GeV)
04/21/23 14
Transition Region: PbWO4 - Lead-GlassPosition Resolution (Eγ = 5.2 GeV)
04/21/23 15
Transition Region: PbWO4 - Lead-GlassReconstructed Energy (Eγ = 5.2 GeV)
04/21/23 16
Transition Region: PbWO4 - Lead-GlassEnergy Resolution (Eγ = 5.2 GeV)
5/10/2010 17
Sensitivity to Magnetic Field
GlueX Col meeting, A. Gasparian
Possible modifications:
change the G10 housing to sift ion housing and extend it to ~1”
insert optical extension
extend the brass strips (look at different options first)No need to change the optical wrapping
The current design do not have extended µ-metal on photocathode Try to shield the FCAL frame with some µ-metal, if it is all possible
5/10/2010 18
Summary
The Hybrid Calorimeter concept have been successfully reapproved with the HyCal calorimeter in the PrimEx experiment.
Technical and methodical aspects of the Hybrid calorimeter are well understood and tested. On-site expertise is available.
HyCal is equipped with ~2000 channel power supply (CAEN) unit; Trigger and analog electronics are old.
1152 PbWO4 high resolution, radiation hard crystal detectors are available for future experiments.
HyCal will stay in Hall B up to the end of PrimEx-II experiment.
GlueX Col meeting, A. Gasparian
5/10/2010 19A. Gasparian GlueX Col meeting, A. Gasparian
19
The End
04/21/23 20
Invariant Mass Resolution
PbWO4
onlyPb-Glassonly