The new Valiant EVO device for TEVAR: What makes it better? * Valiant Evo is an investigational device Prof. Fabio Verzini, MD, PhD, FEBVS Unit of Vascular Surgery, University of Perugia Az.Osp.Perugia, Italy

Transcript of The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized...

Page 1: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

The new Valiant EVO device for TEVAR: What makes it better?

* Valiant Evo is an investigational device

Prof. Fabio Verzini, MD, PhD, FEBVS

Unit of Vascular Surgery,

University of Perugia

Az.Osp.Perugia, Italy

Page 2: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Disclosure

Speaker name:

...............................Fabio Verzini.............................................

I have the following potential conflicts of interest to report:

Consulting for Cook, Gore, Medtronic,

Employment in industry

Stockholder of a healthcare company

Owner of a healthcare company

Other(s)

I do not have any potential conflict of interest

X

Page 3: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Proximal closed web configuration with tip capture

3

Low Profile DesignDelivery System & Stent-Graft enhancements

– Reduced taper tip length

– Internal flush port

– Increased working length

Multi-filament (same as Endurant) vs. Mono-filament Valiant graft material

Minimized profile increases access

to small and tortuous iliacs – up to 4

Fr reduction in profile

24 Fr25 Fr 22 Fr

46-40mm 37-28mm 25-20mm

Valiant Captivia

Valiant Evo* 18 Fr22 Fr 20 Fr

* Valiant Evo is an investigational device

Page 4: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

4

Broad size matrix

• Treat wide range of anatomies

– Increased length (225 mm)

– Smaller diameter (20mm)

– Refined tapering (5 & 6 mm)

• Tailored pieces for specific use (increased tapering, cuff, sizing changes)

FrSG Size (mm)

Covered Length (mm)*

60 100 175 225

20 x

22 x x

25 x x

28 x x

31 x x x

34 x x x x

37 x x x x

40 x x x x

43 x x x x

46 x x x x

18 Fr

22 Fr

20 Fr

* Valiant Evo is an investigational device

Page 5: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Bare Stent

6 or 7 peak

Support

Stent

6 or 7 peak

Internal

Stent

6 or 7 peak

Support Stent

12 or 14 peak

FreeFloClosed Web

Stent Spacing 4/5/6 mm

Body stents

6 or 7 peak

Multifilament Yarn

UHMWPE

Suture (Body +

Seal Stents)

Distal Stent

6 or 7 peak

Stent graft design overview

* Valiant Evo is an investigational device

Page 6: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

DELIVERY SYSTEM MODIFICATIONS VS. VALIANT CAPTIVIA

Tapered Tip

– Length reduced by ~1cm versus Valiant Captivia system (22Fr)

– Length proportionally sized to maintain taper

Working Length and Hydrophilic coating Length

– Working length increase: 10cm

• Valiant Captivia WL = 83cm; Valiant Evo WL = 93cm

– Hydrophilic coating length increase: ~10cm

• Valiant Captivia HCL ~ 70cm; Valiant Evo HCL ≥ 80cm

18Fr –

23.3mm

20Fr –

25.6mm

22Fr –

27.9mm

Valiant

Captiva22Fr – 37.9mm

Length

10

Working Length =

93cm

Hydrophilic

Coating Length ≥

80cm

Page 7: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Valiant EVO Global clinical trial

Design

• Prospective, multi-center, pre-

market, non-randomized, single-arm

trial

Enrollment

• 37 sites worldwide In North America &

EU

• Up to 100 subjects

• First patient in: April 2016

Endpoints

• Safety: Major Adverse Events

(MAEs) within 30-days post-

implantation

• Effectiveness: Technical success at

index procedure and treatment

success at 12-months]

US (22 Centers)

PI: Prof. A. Azizzadeh

OUS (15 Centers)

PI: Prof. F. Verzini

Page 8: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

• Female, 83 y.o.

• Hypertension

• Hypercholesterolemia

• Type 2 diabetes mellitus

• Persistent atrial fibrillation under anticoagulantand antiarrhytmic therapy

• COPD

Persistent coughing and dysphonia

Left vocal cord paralysis

Page 9: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Distal aortic arch penetrating aortic ulcer

Page 10: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Planning and sizing

Proximal

landing zone

Distal

landing zone

Page 11: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Percutaneous

Left brachial

access

Right femoral surgical

cut-down Right fem vein access

for

Cardiac rapid pacing

1 stage: L carotid-subclavian bypass,2 stage: TEVAR w Rapid pacing

Page 12: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Valiant Evo 34-28-175

Page 13: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Prevertebral subclavian embolization

Amplatzer Vascular Plug II 10 mm

Page 14: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Post-procedural

angiogram

30 days post-op CTA

Page 15: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

Next GenerationTEVAR

Page 16: The new Valiant EVO device for TEVAR: What makes it better? · Valiant graft material Minimized profile increases access to small and tortuous iliacs –up to 4 Fr reduction in profile

The new Valiant EVO device for TEVAR: What makes it better?

* Valiant Evo is an investigational device

Prof. Fabio Verzini, MD, PhD, FEBVS

Unit of Vascular Surgery,

University of Perugia

Az.Osp.Perugia, Italy