The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist...

34
The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters UV/Vis generation 886/887 1

Transcript of The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist...

Page 1: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 1

The new UV/Vis generation – 886/887

Metrohm Ion Chromatography

Dr. Katinka Ruth

Product Specialist Competence Center ICMetrohm International Headquarters

Page 2: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 2

Outline

The new UV/Vis generation – 886/887

• New UV/Vis detector• New heated reactor

• For post-column reactions• As column department

• Applications

Page 3: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 3

887 Professional UV/Vis Detector

Hardware

• Diode array detector• UV lamp (deuterium) + Vis lamp (halogen)

Built in as in 844• 8 data channels + 1 reference channel• CH1/CH2 quotient channel omitted• 887 = standalone detector

Combination possible with 850, 881, 882

(≠ conductivity detector)• Connection to PC via USB• Analog out: up to 4 channels

Page 4: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 4

887 Professional UV/Vis Detector

Features

• Same functionality as 844• MagIC Net• T int, T out: New names for better understanding

Tint = integration time

Tout = measuring time• Measuring time = multiple of integration time• Records spectra at any point of the chromatogram

Page 5: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 5

2 ppm nitrite, 4 ppm bromide, 50 ppm nitrate

in artificial sea water (28 g/L NaCl)

A Supp 10 - 250

5 mmol/L Na2CO3, 5 mmol/l NaHCO3

1.0 mL/min

MSM MCS (step after 13.5 min)

218 ± 5 nmSample volume 5 µLAccording to AW CH6-1027-012010

0.0

0.1

0.2

0.3

0.4

0.5

200 225 250 275 300 325 350 375

SpectrumRecord started 18.11.2009, 15:24

Inten

sity

Wavelength / nm

Retention time 9 min (nitrite) Retention time 19 min (bromide)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

200 225 250 275 300 325 350 375

SpectrumRecord started 18.11.2009, 15:24

Inten

sity

Wavelength / nm

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

200 225 250 275 300 325 350 375

SpectrumRecord started 18.11.2009, 15:24

Inten

sity

Wavelength / nm

Retention time 23 min (nitrate)

Feature: Spectrum at any time point

Page 6: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 6

Evaluate absorbance maxima

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

200 225 250 275 300 325 350 375

SpectrumRecord started 18.11.2009, 15:24

Inten

sity

Wavelength / nm

Features

• Define start and end wave length• Automatic evaluation of absorbance maxima• Up to 10 automatic evaluations

Page 7: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 7

Direct and indirect UV detection

Features

• Change polarity via MagIC Net

Page 8: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 8

New assembly of lamps

Features

• Installation from the top• Easy mounting

6.2804.050 Deuterium lamp (UV)

6.2804.060 Halogen lamp (Vis)

Page 9: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 9

887 Professional UV/Vis detector

Technical specifications

• Array with 512 diodes

• Channel λ 190 – 900 nm (increment 1)

• Bunching ± 0 – 100 nm (increment 1)

• Integration time 10 – 254 ms

• Measuring time 50 – 2000 ms

• Noise (expected) 0.1 – 0.2 mAU (similar to 844)

• Resolution 1.4 nm

• Metal free

• Leak sensor on tray

• PEEK detector cellOptical path

Page 10: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 10

887 Professional UV/Vis Detector

Possible combinations

• MagIC Net 2.2 = must• Stand alone UV detector• Controlled by MagIC Net Multi, Professional, and Compact

887 Professional UV/Vis Detector

Page 11: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 11

887 Professional UV/Vis Detector

Possible combinations

• 1 detector: MagIC Net Compact • 2 detectors: MagIC Net

Professional

887 Professional UV/Vis Detector

881or

882

CompactIC

Connector

2.881.00X0 Compact IC pro

2.882.00X0 Compact IC plus

6.2061.120 System Connector ProfIC/Compact IC 

2.887.0010 Professional UV/Vis Detector

Page 12: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 12

887 Professional UV/Vis Detector

Possible combinations

• 1 detector: UV

850

ProfessionalIC

887 Professional UV/Vis Detector

2.850.XXXX Professional IC

2.887.0010 Professional UV/Vis Detector σ σ

• 2 detectors: UV + conductivity

• 3 detectors: UV + 2 x conductivity

in series or parallel detection• MagIC Net Professional

Page 13: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 13

New heated reactor – general info

• Heating up to 150°C, increment 0.1°C• Direct heat transfer, faster heating than 850, 881

<10 min (20°C to 40°C)• Temperature stability: better than 0.05°C• Temperature reproducibility: better than ± 0.2°C• Temperature accuracy: <1°C• MagIC Net 2.2 (Professional and Multi)• Combinations possible with 850, 887, 881, 882• Host for further 872 Extension modules• Robust design

• Two versions:

a) 2.886.0110 Professional Reactor

b) 2.886.0210 Professional Thermostat

Page 14: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 14

a) 2.886.0110 Professional Reactor

For post-column-derivatisation (PCR)

• Intelligent reactor = iReactor

(with chip on reactor plate)• Temperatures up to 120°C• Space to have 4 reactors• Heated mixing-T

Accessories (included)

6.2744.330 Y-connector 3 x UNF 10/32

6.2845.100 Reactor plate complete to PCR Module

6.2845.200 Reactor complete to 6.2845.100

6.1015.100 Metrosep BP 1 Guard/2.0

Page 15: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 15

a) 2.886.0110 Professional Reactor

Setup

• Base plate (iReactor)• + 1 reactor

(0.5 x 2000 mm PEEK-capillary)

dimensions as previous PCR-Box• + 2 reactor e.g. as preheating capillary

for eluent or post column reagent• Up to 4 reactors• Setup depends on application/desired

temperature

Page 16: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 16

b) 2.886.0210 Professional Thermostat

Heated column department

• Compatible with intelligent columns• Column length up to 150 mm• Temperature up to 80°C

Accessories (included)

6.1836.020 Preheating capillary with core, 1.44 m

6.2845.600 Column holder complete to PCR Module

Page 17: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 17

2.886.0210 Professional Thermostat

Setup

Up to 2 columns in the thermostat• e.g. column + pre-column• or 1 x 150 mm + 1 x 100 mm• 1 column is monitored

• Additional pre-heating capillary must be installed

Page 18: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 18

Name reactor plate

Set to work

Last change

Comment

Reactor 1 mounted

Reactor 1 order number

Reactor 1 material

Reactor 1 length

Reactor 1 inner diameter

Reactor 1 comment

Intelligent Thermostat / Reactor

• Chip for reactors as at intelligent columns

• Monitoring / Traceability• 1 Chip per reactor plate

(iReactor)• Data field for up to 4 reactors

Reactor 2 mounted

Reactor 2 order number

Reactor 2 material

Reactor 2 length

Reactor 2 inner diameter

Reactor 1 comment

etc.

Page 19: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 19

2.886.0110 Professional Reactor

Possible combinations

887 Professional UV/Vis Detector

886 ProfessionalReactor

872 IC Pump

881or

882

CompactIC

Connector2.881.00X0 Compact IC pro

2.882.00X0 Compact IC plus

6.2061.120 System Connector ProfIC/Compact IC 

2.887.0010 Professional UV/Vis Detector

2.886.0110 Professional Reactor

2.872.0010 Extension Module IC Pump

6.1015.100 Metrosep BP 1 Guard/2.0

• Transport of PCR-reagent:

High pressure iPump of 872 Extension module

• Use of BP 1 Guard

Page 20: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 20

2.886.0110 Professional Reactor

Possible combinations

887 Professional UV/Vis Detector

886 ProfessionalReactor

881or

882

CompactIC

Connector

2.881.00(2/3)0 Compact IC pro

2.882.00(2/3)0 Compact IC plus

6.2061.120 System Connector ProfIC/Compact IC 

2.887.0010 Professional UV/Vis Detector

2.886.0110 Professional Reactor

• Transport of PCR-reagent:

881 peristaltic pump +

backpressure capillary• Regeneration MSM:

• 800 Dosino• Peristaltic pump of 872.0050

(for non-suppressed systems)

800

Page 21: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 21

2.886.0110 Professional Reactor

Possible combinations

2.850.XXXX Professional IC

2.887.0010 Professional UV/Vis Detector

2.886.0110 Professional Reactor

6.1015.100 Metrosep BP 1 Guard/2.0

• Transport of PCR-reagent:

850 high pressure iPump

(alternative : peristaltic pump)

• Use back pressure column

together with iPump• Flexible detector setup

850

ProfessionalIC

887 Professional UV/Vis Detector

886 Professional Reactor

σ σ

Page 22: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 22

2.886.0110 Professional Reactor

Possible combinations

887 Professional UV/Vis Detector

886 ProfessionalReactor

872 IC Module

872 IC Pump

2.887.0010 Professional UV/Vis Detector

2.886.0110 Professional Reactor

2.872.0030 Extension Module IC Module

2.872.0010 Extension Module IC Pump

6.2061.100 Bottle holder (ProfIC)

6.2061.110 Tray with sensor

6.1015.100 Metrosep BP 1 Guard/2.0

• Transport of PCR-reagent:

872 Extension Module IC Pump or

872 Sample Prep (peristaltic pump)

• Transport of eluent + injection:

872 Extension Module IC Module

• Bottle holder + tray

Page 23: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 23

2.886.0210 Professional Thermostat

Possible combinations

887 Professional UV/Vis Detector

886 ProfessionalThermostat

872 IC Module

2.887.0010 Professional UV/Vis Detector

2.886.0210 Professional Thermostat

2.872.0030 Extension Module IC Module

6.2061.100 Bottle holder (ProfIC)

6.2061.110 Tray with sensor

• Simple stand-alone UV-system• 886 as column department• Bottle holder + tray

Page 24: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 24

UV detection – suppressed or non-suppressed

+MSM +MCS +MSM-MCS –MSM-MCS

Noise 0.05 – 0.075 mAU Noise 0.05 – 0.075 mAU Noise 0.15 – 0.2 mAU500 ppb NO2

-, Br-, NO3- Mean (n = 8)

20 µL loop 218 ± 15 nm45°C Integration time 13 msA Supp 15 – 150/4.0 Measuring time 1 s0.7 mL/min 5 mM Na2CO3 + 0.3 mM NaOH

Page 25: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 25

NO2

+MSM

+MCS+MSM-MCS

–MSM-MCS

Full width at half maximum 0.40 0.40 0.35Height 1.8 1.8 1.8Area 0.79 0.80 0.70Noise 0.09 0.09 0.18S/N 21 21 10Theoretical plates 1619 1362 2041

Br

+MSM

+MCS+MSM-MCS

–MSM-MCS

Full width at half maximum 0.53 0.52 0.62Height 0.7 0.7 0.5Area 0.38 0.39 0.27Noise 0.09 0.09 0.18S/N 8 8 3Theoretical plates 1782 1709 3068

NO3

+MSM

+MCS+MSM-MCS

–MSM-MCS

Full width at half maximum 0.65 0.66 0.66Height 1.5 1.5 1.1Area 1.02 1.07 0.80Noise 0.09 0.09 0.18S/N 17 17 6Theoretical plates 1533 1324 2335

Conclusion Area, height, noise, S/N = suppressed better

Theor. Plates = non-suppressed better

UV detection – suppressed or non-suppressed

Page 26: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 26

Recommendation• Chemical suppression (MSM)

Improvement for• Noise → S/N• System peak• Injection peak

• No MCS

Improvement for• Peak broadening• costs

+ MSM + MCS

+ MSM- MCS

- MSM- MCS

UV detection – suppressed or non-suppressed

Page 27: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 27

Applications

All existing applications published with 844 or Lambda 1010(reactor dimensions identical to previous PCR-Box)

• Direct UV/Vis detection• Indirect UV/Vis detection• Pre column derivatisation + UV/Vis detection• Post column derivatisation + UV/Vis detection

Page 28: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 28

Applications

• Transition metals• Chromate• Bromate• Silicate• Cyanide, cyanogen chloride• Aluminium• ...

Potential new applications for PCR

• Amino acids• Ammonium next to high amounts of sodium• Au, Ag, Hg, Pt, Pd

Examples for Post column reactions (PCR)

Page 29: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 29

Applications

887 Professional UV/Vis detector

500 ppb NO2-, NO3

- in artificial sea water (28 g/L NaCl)

A Supp 10 – 250/4.05 mmol/L Na2CO3, 5 mmol/l NaHCO30.7 mL/min5 µLMSM MCS218 nm ± 15 nmT int 13 ms, T out 1 s

AW CH6-1027-012010

NO2-

NO3-

Cl-

Page 30: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 30

UV detection of nitrite and nitrate

Calibration 50 ppb – 20 ppmIon Relative

standard deviation

Correlation coefficient

Nitrite 1.163 0.999986

Nitrate 1.113924 0.999987

Page 31: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 31

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 min

0

100

200

300

400

mAU

Abs.1

Cu

Ni

Zn

Co

Pb

Mn

Cd

Applications

Transition metals

10ppm Cu, Ni, Zn, Co, Mn,20ppm Cd, 50ppm Pb

Metrosep C 5 – 150/4.615 mmol/L oxalic acid pH 3.5 (NH3)1.0 mL/min (eluent)0.5 mL/min (PCR)10 µL510 nm ± 11 nm

PCR-reagent0.15 mmol/L PAR0.4 mol/L NH3

80 mmol/L HNO3

Page 32: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 32

Applications

Amino acids

USP 27 norm for amino acids• Requires 120°C• Possible with new PCR reactor

0.5 mM amino acids(20 compounds)Metrosep Amino Acids 1 – 100/4.0USP eluent570 nm

PCR-reagentNinhydrin, hydrindatindimethylsulfoxid,lithium acetate, acetic acid(N2 purged)

Page 33: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 33

Applications

Bromate

• According to draft norms

ISO/DIS 11206 + EPA 326• PCR, tri-iodide method• UV absorbance at 352 nm

• Metrosep A Supp 16 – 100/4.0• 0.5 – 5 ppb Bromate

Bromate 4.8 min

Page 34: The new UV/Vis generation – 886/887 Metrohm Ion Chromatography Dr. Katinka Ruth Product Specialist Competence Center IC Metrohm International Headquarters.

UV/Vis generation 886/887 34

Summary

UV/VIS generation – 886/887

• Professional UV/Vis detector

MagIC Net

8 channels (wavelength + bunching)

spectra at any time point

functionality as 844

• Professional Thermostat / Reactor

Faster heating + higher temperatures (direct heat transfer)

iReactor

2 MPa backpressure for smooth adding of reagent

• Available in summer 2010 (depending on MagIC Net 2.2)