THE MOST ADVANCED SOLAR INVERTER · MONITORING AND REMOTE O&M ·Freesun Portal ·Freesun Web...
Transcript of THE MOST ADVANCED SOLAR INVERTER · MONITORING AND REMOTE O&M ·Freesun Portal ·Freesun Web...
THE MOST ADVANCEDSOLAR INVERTEROur experience in developing and manufacturing high power Variable Speed Drives and Softstarters, in the control of diverse applications and the integration of all types of grid topologies, have allowed us to make the most robust, reliable and efficient solar inverter of the market.
In Power Electronics we believe we are a SERVICE and MANUFACTURING company of power electronics. We help you along the whole product life cycle, from plant lay-out the after sales technical service, by providing close, flexible and customer oriented assistance that ensures we keep long-term relationships with our clients and partners of the INDUSTRIAL and SOLAR PHOTOVOLTAIC sectors.
Our HEAD OFFICE in Valencia (Spain) houses our high technology R&D centre as well as the electronics manufacturing. Additionally, two FACTORIES with a net area of more than 20.000 sqm with an available area of 80.000 sqm can produce annually 1GW of solar and 5GW of industrial equipment. All under the perspective of a vertical integration that enhances the production quality and flexibility.
POWER ELECTRONICSTHE COMPANY
FREESUN SOLAR INVERTER / POWER ELECTRONICS
INDUSTRIAL DIVISION - SOLAR DIVISION
VARIABLE SPEED DRIVESELECTRONIC SOFT STARTERS
SOLAR INVERTERSSOLAR POWER STATIONS
01.
PO
WE
R E
LEC
TR
ON
ICS
2_3
POWER ELECTRONICS WORLDWIDE
MEXICO
BRAZIL
UNITEDSTATES
PERU
CHILE
UNITEDKINGDOM
ITALY
SPAIN
www.power-electronics.com
FRANCE
COLOMBIA
MOROCCO
CLOSE TO YOU
INDIA
SOUTH AFRICA
NEWZEALAND
AUSTRALIASINGAPORE
KOREA
JAPAN
CHINA
GERMANY
INTERNATIONAL PRESENCE in over 20 countries with more than 500 worldwide employees. Our branches do not only have a sales presence, we deliver on-site local technical assistance and updated spare parts stock that ensures our unique service response commitment.
01.
PO
WE
R E
LEC
TR
ON
ICS
Power Electronics is a family-owned multinational who began manufacturing and selling variable speed drives and soft starters 25 years ago.
POLAND
RUSSIA
4_5
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Freesun product range covers any possible requirement for your solar installationOur expertise is divided into two main fields, the industrial one where we manufacture VSD (variable speed drives) and soft starters, both in low and medium voltage, and the other is the solar business, where we manufacture Solar Inverters, our Freesun product range covers any possible requirement for your solar installation.
Since our birth back in 1987 we haven’t ceased to grow and compete against worldwide corporations, however our philosophy of giving service where others fail to do so, has brought us to where we are now. We continue to grow at great speed every year, and we hope that the near future will be of growth and expansion, consolidating more than 40 markets where we already are and adding some new horizons to our future.
SAVING ENERGY FOR THINGSTHAT MATTERIn Power Electronics we know that the modern world is getting faster and more complicated by the day and that often our priorities in life can get confused. When we design and create our products, we don’t only think about numbers and graphics, we think about our clients, their companies and the surrounding environment, like we would think about our own.
And that is exactly why we understand that there are more things in life, not only work. We don’t want our clients to worry about our products, we want to save their energy so that they can invest it in the things that really matter, their families, their friends, their hobbies...
We will take care of the rest: we will set up free technical seminars and courses so that our clients and their technicians can get to know the products as well as we do, we will assist with the commissioning with no additional cost because we believe in work well done, we will offer you a 24h phone line so that you can always ask what you want to know no matter the time of day or night, and we will never let our clients down if they have a problem... We will take care of all these things so that you can save your energy for things that really matter...
01.
PO
WE
R E
LEC
TR
ON
ICS
6_7
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Therefore, flexibility and specialisation play a key role. We are flexible to be able to supply advanced products delivered in very short lead times, service our product ranges in any market where we have a branch within 24 hours, commission our devices worldwide, offer a worldwide hotline 24/7…
We are ready to give technical advice and support about our products and the applications in which they are installed. Our clients also have at their disposal our engineering and consulting department, which comprise a wide number of highly skilled and experienced engineers in the development of tailor-made solutions.
POWER ON SUPPORT is the concept which explains the customer oriented strategy implemented by Power Electronics since its origins more than 25 years ago. We do not simply consider ourselves an advanced power electronics manufacturer, but a services company in the market to take care of all our customers’ needs and adapt to their requirements.
Power on Supportcustomer oriented strategy
ENGINEERING SUPPPORT
FREE COMISSIONING
5 YEAR WARRANTY
24/7 CUSTOMER SUPPORT
24/7 ONSITE ASSISTANCE
MAINTENANCE CONTRACT
SPARE PARTS WARRANTY
99% AVAILABILITY
8_9
01.
PR
ESE
NTA
CIÓ
N
01.
PO
WE
R E
LEC
TR
ON
ICS
VALUE CHAIN SUPERVISION
FACTORY TESTED
IMMEDIATE DELIVERY
RELIABLE ENGINEERING
DESIGN FLEXIBILITY
HIGH QUALITY COMPONENTS
Vertical integration for customers satisfactionVertical integration of the whole production process allows us to offer a fully flexibility, outstanding quality and immediate delivery time, thanks to complete production supervision and scheduling of the electronics, frames and cabins, assembly and testing.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
IndexPage 14 Indoor Utility Scale Solar InvertersPage 16 Freesun HEPage 30 Freesun HESPage 34 Freesun HET
Page 38 Outdoor Utility Scale Solar InvertersPage 40 Freesun HECPage 52 MV Compact Station Page 56 MV Outdoor Set Page 60 Freesun HEC-ULPage 68 Freesun HEK
Page 72 Energy Storage Solar SolutionsPage 74 Freesun BESSPage 78 Freesun PCSPage 82 Freesun PPC
Page 86 Commercial Scale Solar InvertersPage 88 Freesun LVT
Page 96 Monitoring SolutionsPage 98 Freesun PortalPage 100 Freesun Data CenterPage 102 Freesun Web/App Display
Page 104 Accessories & Customised Solutions
Page 108 Ordering Info & Standards
Page 112 Power on Support
Page 114 References
Page 118 Warranty
Page 119 Contact
10_11
02.
IND
EX
Freesun means experience, service, flexibility, reliability and commitment with your investment. The ultimate Freesun series and accessories provide a solution for medium and high power solar plants. Freesun’s design and topology bring together the engineering expertise in industrial power electronics development and the solar plants economic and technical requirements.
IND
OO
R U
TIL
ITY
SC
AL
ES
ola
r in
vert
ers
OU
TD
OO
R U
TIL
ITY
SC
AL
ES
ola
r in
vert
ers
CO
MM
ER
CIA
L S
CA
LES
ola
r in
vert
ers
EN
ER
GY
STO
RA
GE
So
lar
solu
tio
ns
FREESUN SOLAR INVERTER / POWER ELECTRONICS
FREESUN HE200kVA to 1390kVA
270, 300, 330, 360Vac1000Vdc, 10 MPPt, Extended MPPt range
FREESUN HES200kVA-1250kVA
6kV-36kVac1000Vdc
Oil transformer, 2L+P switchgear
FREESUN MV STATION400kVA – 2000kVA
6kV-36kVacOil transformer, 2L+P switchgear
FREESUN LVT20kW-100kW
400Vac, Built-in transformer1000Vdc, 1 MPPt
Outdoor and Indoor Inverter
FREESUN PCS125kVA- 1800kVA360Vac – 440VAc
1000Vdc Up to 4 independent battery strings
Outdoor Battery Inverter
FREESUN PCS-Skid Station200kVA-3000kVA
4.16kV- 34.5kV1000Vdc,
Up to 8 independent battery stringsOpen Skid Station
FREESUN HEC-UL160kVA-1200kVA
208, 330, 360, 390Vac600Vdc - 1000Vdc, 4 MPPt
FREESUN HEC600kVA - 1700kVA360, 380, 400Vac
1000Vdc, Extended MPPt range
FREESUN HEK200kVA-2500kVA
4.16kV- 34.5kV600Vdc - 1000Vdc,
4 MPPt / Open Skid Station
12_13
02.
FR
EE
SUNACCESSORIES
FREESUN HET200kVA-2000kVA
6kV-36kVac1000Vdc
Dry transformer, 2L+P switchgear
FREESUN MV OUTDOOR SET400kVA – 2000kVA
6kV-36kVacOutdoor transformer &
2L+P Switchgear Station
FREESUN ESS100kWh- 2MWh600Vdc-800Vdc
1C to 4.2CDischarge capacity Powered by Kokam
STRING SUPERVISORS·SFS16, 24 Wall mounted
·SFS08 Wall mounted
DC DISCONNECTION & PROTECTION·Built-in module
·Outdoor wall-mounted·Outdoor stand-alone
WEATHER ACCESSORIES·Irradiance sensor
·Pyranometer·Weather Station
·Security cameras·Optical Probe
AC DISCONNECTION& PROTECTION
·Built-in AC circuit breaker·Built-in AC fuses and disconnector
·Stand-alone Indoor AC cabinet
MONITORING AND REMOTE O&M·Freesun Portal
·Freesun Web Display·Freesun App Display
CONFIGURATION·Freesun Smart Configurator
PLANT MANAGEMENT· Freesun PPC Power Plant Controller· Freesun PCI Power Control Interface
· Freesun PIK Power Independence Kit
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
INDOOR UTILITY SCALESolar Inverters
02.
CO
NT
EN
IDO
03.
FR
EE
SUN
14_15
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HESolar Inverter
16_17
POWER ELECTRONICS´ HE solar inverter is the best choice in quality and reliability. It is available in four output voltages from 270Vac to 360Vac, covering a power range from 200kVA to 1390kVA.
The truly modular and redundant inverter, all systems are repeated in each module, control board, power stage, cooling system and disconnectors. All being coupled by the DC and AC buses so that the system provides redundancy in case of the failure of a module. FREESUN HE frames can be featured with up to 10 modules that are able to perform the MPPt tracking and act as a Master. Large power stations equipped with two TWIN Freesun HE inverters can be synchronized and connected to one step-up transformer with a single winding.
Best in class topology and unique after-sales service in the market represents the best guarantee for your investment.
The truly modular inverter, all systems are
repeated in each module
03.
FR
EE
SUN
HE
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Freesun HE topology gets the competiveness of central inverters and the availability of string inverters. It is constructed with independent modules from 100 to 139kVA, each module includes its own control board, power stage and cooling system, being coupled by the DC and AC buses. In the end, an issue only affects to one of the units and never the entire system. At the same time, the power of the faulty module is sent to an adjoining operative module, so that it only reduces the injected power when the maximum rated power is reached. If not, you won’t lose a kWh and you might probably never realize that a module is not operative.
All the units work in parallel together commanded by the master. This master is the main governor of the system and is responsible of the MPPt tracking, synchronization sequence, overall protection…. Freesun HE is smartly designed to last. The automatic mode shifts every night the master role by comparing the register of energy production of every module. The one with less energy produced (kWh) will act as a master next early morning with the first sunbeams. This feature enables a homogeneous wear and tear of all the components in the modules, extends the product lifetime and MTBF ratio.
Automatic RedundantModular Master Slave System
0 3 5 7 9 11 13 15 17 19 21
1200
900
600
300
1500
AUGUST
SEPTEMBER
PO
WE
R (
KW
)
TIME (h)
Available solar Power (kW)Freesun Production (kW) -1 Module faultCompetitors Production (kW) -1 Module fault
4:25
10kW
4:354:30
5kW
15kW
4:20 4:40
August saved Energy (kWh)September saved Energy (kWh)
18_19
03.
FR
EE
SUN
HE
When addressing the selection of a solar inverter manufacturer, there are crucial points that should be considered first and inverter’s efficiency is one of the most important. On low radiation conditions, a modular inverter operates at higher efficiency levels than a similarly sized central inverter. By shutting off unneeded power modules, modules load increases to get the maximum available efficiency. At the same time, a lower power rating of the inverter units allow to start feed-in earlier in the morning and to stop later in the afternoon. As a result, throughout the entire service life of the PV plant, HE will generate higher yields than central or string inverters.
EF
FIC
IEN
CY
POWER
A MODULAR AND REDUNDANT INVERTER GENERATES
HIGHER YIELDS
FREESUN SOLAR INVERTER / POWER ELECTRONICS
The internal fan moves the clean air through the dissipation surface that allows HE Series to be totally isolated. This mechanical design offers maximum protection for the electronics without the risk of dust filters clogging which require regular maintenance.
Totally Sealed
Independent cooling in each module reduces the fan power consumption. The inverter reduces to the maximum the Stand-by consumption at low capacity. Each hot zone of the module has 3 independent fans smartly located and controlled through its own control board and temperature sensors.
Power Electronics´experience in VSD has been implemented in the main power fans to reduce the energy consumption to the minimum and to boost the cooling capacity for PV installation situated higher than 3000 meters above sea level. Energy saving with greater cooling features.
No power derating until 50°C due its oversized IGBT’s, its mechanical design and efficient cooling system.
Efficient Cooling System
10%
45 50 55 60 65 70 75 80
IGBT TEMPERATURE [ºC]
Fan speed (%) Fan power consumption (%)
20%
30%
40%
50%
60%
70%
80%
90%
100%
20_21
Its modular design allows to isolate and replace all the components with no effort, saving time and money during routine inspections. Each module is equipped with guided wheels that enable an easy frontal extraction only with the aid of the delivered trolley.
Easy to install
03.
FR
EE
SUN
HE
Maximum DC bus flexibility that allows up to 10independent MPPt per inverterFurthermore, design each MPPt’s rated power as you wish, neither mechanical, hardware or software restriction to fit all the customer’s requirements.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
AC Power configurable rating and MPPt DC voltage range, the customer could adjust the limits of the inverter to increase the module power from 100kVA to 139kVA. Power electronics provides you competitiveness tools.
Configurable Rating
Freesun HE inverter is limited by the output current at 50°C, no matter whether it is active or reactive current. Just an appropriate selection of the units considering the reactive capability curves allow the user to install Freesun HE with any power factor conditions.
During the night Freesun HE inverter can shift to reactive power compensation mode. The inverter will work either following an external dynamic signal from a power analyzer, or injecting a pre-set reactive power (kVAr).
Accurate and flexible reactive capability
Extended MPPt
MPPt Window (VDC)[2]
# MODULES 382V-900V 425V-900V 467V-900V 510V-900V
2 200kVA 230kVA 250kVA 280kVA
Nominal AC Output Power
(kVA)[1]
3 300kVA 340kVA 380kVA 420kVA4 400kVA 460kVA 500kVA 560kVA5 500kVA 570kVA 630kVA 700kVA6 600kVA 680kVA 750kVA 830kVA7 700kVA 800kVA 880kVA 970kVA8 800kVA 910kVA 1000kVA 1110kVA9 900kVA 1030kVA 1130kVA 1250kVA10 1000kVA 1140kVA 1250kVA 1390kVA
AC Output Voltage 270Vac 300Vac 330Vac 360Vac
[1] Values at 50°C, 50Hz [2] Values at 1.00Vac nom and cos Φ= 1. Consult Power Electronics for derating curves.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Using the latest modulation techniques, inspired by the most accurate and powerful motor control applications, has lead to the widest MPPt full power window in the solar market. Update your OND files as soon as possible to check how the most advanced control software and our unique topology boost your PV plant performance rates.
22_23
03.
FR
EE
SUN
HE
Freesun HE firmware includes the latest utility interactive features (LVRT, OVRT, FRS, FRT, Anti-islanding, active and reactive power curtailment…), being compatible with all the specific requirements of the utilities in any country (France, Germany, Italy, Israel, Japan, Mexico, Puerto Rico, Rumania, South Africa, Spain, UK, U.S.A…)
LVRT or ZVRT (Low Voltage Ride Through): Our inverter withstand any voltage dip profile required by the local interconnection code, it will immediately feed the fault with full reactive power, as long as the protection limits are exceeded.
FRS: The Frequency Regulation Systems algorithm curtails the active power along a preset characteristic curve supporting the grid stabilization. This functionality, together with a Freesun PPC; will control the PV active power injection in electric grids powered by diesel Generators.
Freesun HE can perform simultaneously two anti-islanding protection methods: Passive and Active method. Both certified according to IEC 62116 and IEEE1547.
The advance control allows the inverter to support the grid through reactive power injection or phase shift control by selecting: a fixed cos φ, dynamic cos φ, preset cos φ(P) continuous curve, preset Q(V) step or continuous curve.
Dynamic grid support
PV INVERTERLOAD (%)
GEN SET LOAD (%)
FREQUENCY (Hz)50Hz
0 %
50%
100%
0 %
50%
100%
52Hz
Min GenSet Load
1.2
1.4
1
0.8
0.6
0.4
0.2
0
-1 0 1 2 3 4
BDEWPO12.3 CEI-016PREPA HECO
FULL VOLTAGE RIDE THROUGH COMPATIBILITY
SECONDS
p.u.
VO
LTA
GE
FREESUN SOLAR INVERTER / POWER ELECTRONICS
360VAC - MPPt Window 510Vdc-900VdcFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8 9 10
FREESUN HE FS0280IH FS0420IH FS0560IH FS0701IH FS0830IH FS0970IH FS1110IH FS1250IH FS1390IH
OU
TPU
T
Nominal AC Power(kVA) at 50°C 280 420 560 700 830 970 1110 1250 1390Nominal AC Current (A) at 50°C 444 667 889 1111 1333 1555 1778 2000 2222Operating Grid Voltage(VAC) 360VacOperating Range, Grid Frequency 50Hz - 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cosi phi)[1] 0.0 leading...0.0 lagging / Reactive power injection at nightNumber AC connections per pole 4x240mm2xM12 4x240mm2xM12 8x240mm2xM12
INP
UT
MPPt Voltage Window (VDC)[2] 510V-900VMPPt window @full power (VDC)[3] 568V-820VMax. permissible DC voltage (VAC) 1000VRated DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000A 2250A 2500A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY Maximum Efficiency PAC, nom (η) 98.6% 98.6% 98.6%
Euroeta (η) 98.2% 98.3% 98.4%
Maximum Standby Consumption (Pnight) < approx. 120W < approx. 240W < approx. 400W
Control Power Supply 3 x 400V, 50/60Hz, (VRT compatible inverters equipped with internal UPS)
CA
BIN
ET Dimensions [WxHxD] mm 2100x2080x1020 3372 x 2080 x 1020 5260 x 2080 x 1020
Weight (kg) 1650 2900 4500Air flow Intake through rear lower part blown out through upper sideType of ventilation VSD temperature controlled, Air-cooled
EN
VIR
ON
-M
EN
T
Degree of protection Indoor IP21Permissible Ambient Temperature -20°C …+50°CRelative Humidity 10% to 95% Non condensingMax. Altitude (above sea level) 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[4] < 79 dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App Display or Freesun Web DisplayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP) Optional GSM/GPRSAnalogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 /Modbus RTUPlant Controller Interface Ethernet / Modbus / TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Monitoring[5] Standard built inHumidity Control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC fuses & disconnectorsGeneral DC Protection & Disconn. Optional: Integrated in empty modules or externalModule AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. Motorized MCCBOvervoltage Protection AC, DC Inverter and Auxiliary Supply type 2 - Internal StandardLightning Protections Optional (Integrated in the inverter)
HE TechnicalCharacteristics 360VAC
[1] [1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00Vac nom and cos Ф = 1. Consult Power Electronics for derating curves.[3] Values at 1.00Vac nom and cos Ф = 1 and Tamb=50°C.
NOTES [4] Sound pressure level at a distance of 1m from the rear part.[5] In cases where the installation has the positive pole or the negative pole earth connected, this protection will be disconnected.
24_25
03.
FR
EE
SUN
HE
330VAC - MPPt Window 467Vdc-900VdcFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8 9 10
FREESUN HE FS0250IH FS0380IH FS0501IH FS0630IH FS0750IH FS0880IH FS1001IH FS1130IH FS1251IH
OU
TPU
T
Nominal AC Power(kVA) at 50°C 250 380 500 630 750 880 1000 1130 1251Nominal AC Current (A) at 50°C 438 657 876 1095 1314 1533 1752 1971 2190Operating Grid Voltage(VAC) 330VacOperating Range, Grid Frequency 50Hz - 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cosi phi)[1] 0.0 leading...0.0 lagging / Reactive power injection at nightNumber AC connections per pole 4x240mm2xM12 4x240mm2xM12 8x240mm2xM12
INP
UT
MPPt Voltage Window (VDC)[2] 467V-900VMPPt window @full power (VDC)[3] 511V-820VMax. permissible DC voltage (VAC) 1000VRated DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000A 2250A 2500A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6%
Euroeta (η) 98.2% 98.3% 98.4%
Max. Standby Consumption (Pnight) < approx. 120W < approx. 240W < approx. 400W
Control Power Supply 3 x 400V, 50 / 60Hz, (VRT compatible inverters equipped with internal UPS)
CA
BIN
ET Dimensions [WxHxD] mm 2100x2080x1020 3372 x 2080 x 1020 5260 x 2080 x 1020
Weight (kg) 1650 2900 4500Air Flow Intake through rear lower part blown out through upper sideType of ventilation VSD temperature controlled Air-cooled
EN
VIR
ON
-M
EN
T
Degree of protection Indoor IP21Permissible Ambient Temperature -20°C …+50°CRelative Humidity 10% to 95% Non condensingMax. Altitude (above sea level) 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[4] < 79 dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App Display or Freesun Web DisplayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP) Optional GSM/GPRSAnalogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 /Modbus RTUPlant Controller Interface Ethernet / Modbus / TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Monitoring[5] Standard built inHumidity Control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC fuses & disconnectorsGeneral DC Protection & Disconn. Optional: Integrated in empty modules or externalModule AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. Motorized MCCBOvervoltage Protection AC, DC Inverter and Auxiliary Supply type 2 - Internal StandardLightning Protections Optional (Integrated in the inverter)
HE TechnicalCharacteristics 330VAC
[1] [1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00Vac nom and cos Ф = 1. Consult Power Electronics for derating curves.[3] Values at 1.00Vac nom and cos Ф = 1 and Tamb=50°C.
NOTES [4] Sound pressure level at a distance of 1m from the rear part.[5] In cases where the installation has the positive pole or the negative pole earth connected, this protection will be disconnected.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
300VAC - MPPt Window 425Vdc-900VdcFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8 9 10
FREESUN HE FS0230IH FS0340IH FS0460IH FS0570IH FS0680IH FS0801IH FS0910IH FS1030IH FS1140IH
OU
TPU
T
Nominal AC Power(kVA) at 50°C 230 340 460 570 680 800 910 1030 1140Nominal AC Current (A) at 50°C 438 657 876 1095 1314 1533 1752 1971 2190Operating Grid Voltage(VAC) 300VacOperating Range, Grid Frequency 50Hz - 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cosi phi)[1] 0.0 leading...0.0 lagging / Reactive power injection at nightNumber AC connections per pole 4x240mm2xM12 4x240mm2xM12 8x240mm2xM12
INP
UT
MPPt Voltage Window (VDC)[2] 425V-900VMPPt window @full power (VDC)[3] 466V-820VMax. permissible DC voltage (VAC) 1000VRated DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000A 2250A 2500A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6%
Euroeta (η) 98.2% 98.3% 98.4%
Max. Standby Consumption (Pnight) < approx. 120W < approx. 240W < approx. 400W
Control Power Supply 3 x 400V, 50 / 60Hz, (VRT compatible inverters equipped with internal UPS)
CA
BIN
ET Dimensions [WxHxD] mm 2100x2080x1020 3372 x 2080 x 1020 5260 x 2080 x 1020
Weight (kg) 1650 2900 4500Air Flow Intake through rear lower part blown out through upper sideType of ventilation VSD temperature controlled Air-cooled
EN
VIR
ON
-M
EN
T
Degree of protection Indoor IP21Permissible Ambient Temperature[3] -20°C …+50°CRelative Humidity 10% to 95% Non condensingMax. Altitude (above sea level)[3] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[4] < 79 dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App Display or Freesun Web DisplayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP) Optional GSM/GPRSAnalogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 /Modbus RTUPlant Controller Interface Ethernet / Modbus / TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Monitoring[5] Standard built inHumidity Control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC fuses & disconnectorsGeneral DC Protection & Disconn. Optional: Integrated in empty modules or externalModule AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. Motorized MCCBOvervoltage Protection AC, DC Inverter and Auxiliary Supply type 2 - Internal StandardLightning Protections Optional (Integrated in the inverter)
HE TechnicalCharacteristics 300VAC
[1] [1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00Vac nom and cos Ф = 1. Consult Power Electronics for derating curves.[3] Values at 1.00Vac nom and cos Ф = 1 and Tamb=50°C.
NOTES [4] Sound pressure level at a distance of 1m from the rear part.[5] In cases where the installation has the positive pole or the negative pole earth connected, this protection will be disconnected.
26_27
03.
FR
EE
SUN
HE
270VAC - MPPt Window 382Vdc-900VdcFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8 9 10
FREESUN HE FS0200IH FS0300IH FS0400IH FS0500IH FS0600IH FS0700IH FS0800IH FS0900IH FS1000IH
OU
TPU
T
Nominal AC Power(kVA) at 50°C 200 300 400 500 600 700 800 900 1000Nominal AC Current (A) at 50°C 428 642 856 1070 1284 1485 1712 1926 2140Operating Grid Voltage(VAC) 270VacOperating Range, Grid Frequency 50Hz - 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cosi phi)[1] 0.0 leading...0.0 lagging / Reactive power injection at nightNumber AC connections per pole 4x240mm2xM12 4x240mm2xM12 8x240mm2xM12
INP
UT
MPPt Voltage Window (VDC)[2] 382V-900VMPPt window @full power (VDC)[3] 410V-820VMax. permissible DC voltage (VAC) 900V, 1000V (Optional)Rated DC current (A) 480A 720A 960A 1200A 1440A 1680A 1920A 2160A 2400A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6%
Euroeta (η) 98.2% 98.3% 98.4%
Max. Standby Consumption (Pnight) < approx. 120W < approx. 240W < approx. 400W
Control Power Supply 3 x 400V, 50 / 60Hz, (VRT compatible inverters equipped with internal UPS)
CA
BIN
ET Dimensions [WxHxD] mm 2100x2080x1020 3372 x 2080 x 1020 5260 x 2080 x 1020
Weight (kg) 1650 2900 4500Air Flow Intake through rear lower part blown out through upper sideType of ventilation VSD temperature controlled Air-cooled
EN
VIR
ON
-M
EN
T
Degree of protection Indoor IP21Permissible Ambient Temperature[3] -20°C …+50°CRelative Humidity 10% to 95% Non condensingMax. Altitude (above sea level)[3] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[4] < 79 dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App Display or Freesun Web DisplayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP) Optional GSM/GPRSAnalogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 /Modbus RTUPlant Controller Interface Ethernet / Modbus / TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Monitoring[5] Standard built inHumidity Control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC fuses & disconnectorsGeneral DC Protection & Disconn. Optional: Integrated in empty modules or externalModule AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. Motorized MCCBOvervoltage Protection AC, DC Inverter and Auxiliary Supply type 2 - Internal StandardLightning Protections Optional (Integrated in the inverter)
HE TechnicalCharacteristics 270VAC
[1] [1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00Vac nom and cos Ф = 1. Consult Power Electronics for derating curves.[3] Values at 1.00Vac nom and cos Ф = 1 and Tamb=50°C.
NOTES [4] Sound pressure level at a distance of 1m from the rear part.[5] In cases where the installation has the positive pole or the negative pole earth connected, this protection will be disconnected.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HE Efficiency CurvesOperational Diagram
EFFICIENCY CURVES
OPERATIONAL DIAGRAM
1 Module
3 Modules
4 Modules
7 Modules
9 Modules
10 Modules
e (%
)
P / Pnom (%)
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%84
86
88
90
92
94
96
98
E�ciency curves from 1 to 10 100 kVA modules, 550 Vdc.Consult Power Electronics for other configurations.
+
-
DC
SWITCHSINUSOIDAL
FILTERINVERTER
BRIDGEDC
BUSAC
CONTACTOR
M
AUTOMATIC
CIRCUIT
BRAKER
T(ºC)
A
270-
360V
AC
AC
BU
S
M1.1
(+)
EM
CFI
LTE
R
UP
TO
10
MODULES
OVERVOLTAGEPROTECTION[2]
CA
NC
OM
MU
NIC
ATI
ON
OP
TIC
FIB
ER
SY
NC
HR
ON
IZA
TIO
N
EM
CFI
LTE
RMODULE
1
DC
BUSAC
CONTACTOR
M
M1.2
(+)
M1.n
(+)
M1.1
(-)M1.2
(-)
M1.n
(-)
T(ºC)
A A
A
R
S
TPE
OVERVOLTAGE
PROTECTION
[2]
Aux
iliar
yPo
wer
Supp
ly23
0VA
C
M10.1
(+)M10.2
(+)
M10.n
(+)
M10.1
(-)
M10.2
(-)
M10.n
(-)
ETH
ER
NE
TC
OM
MU
NIC
ATI
ON
ETHERNET
SWITCHWIFI
L1
L2
L3
270
–36
0VA
CO
UTP
UT
POW
ER
OVERVOLTAGE
PROTECTION
[2]
RS485
MODULE
10
RS485
A
A
A
A
+
-
CONTROL
CONTROL
STRING SUPERVISOR
METEO - STATIONPOWER PLANT CONTROLLER
FREESUN DATA CENTER
FREESUN APP DISPLAY
FREESUN WEB DISPLAY Communication Ports: RS485, RS232, USB
Analogue and Digital E/S
ISOLATION MONITORING[1]
MO
DU
LAR
MP
Pt D
C B
US
UP
TO 1
0 M
PP
t
DCSWITCH
INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
400V
AC
EXT
ERN
AL
POW
ER S
UPP
LY
[1] In positive pole or negative pole earth connected installations, the protection must be disconnected.[2] Optional AC and DC lightning protection.
EM
CFI
LTE
RE
MC
FILT
ER
CIRCUIT BREAKER
28_29
03.
FR
EE
SUN
HE
HE Dimensions and weights
FRAME 1
FRAME 2
FRAME 3
2100
2080
1020
3372 1020
2080
5260
2080
1020
FRAME WEIGHT (kg)1 1650
FRAME WEIGHT (kg)2 2900
FRAME WEIGHT (kg)3 4500
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HESSolar Inverter
30_31
Freesun HES-R is the most compact, reliable and cost effective 1.25MW concrete
solar power station
HES by POWER ELECTRONICS is a prefabricated concrete station easy to install and totally protected from harsh conditions, the HES represents a cost-effective turnkey solution for large installations.
We offer a wide portfolio of Solar Power Stations from 250kVA to 1250kVA. They are featured with oil-immersed step-up transformer, SF6 air insulated MV switchgear, DC and AC disconnection and protection, tailored to comply with any client requirements. The Freesun HES station is easy to connect and to install in field, reducing the transportation, installation and commissioning costs.
Maximize the life and availability of your PV plant relying on Freesun HE inverters and Power Electronics conditions.
03.
FR
EE
SUN
HE
S
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HES TechnicalCharacteristics
FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
MEDIUM VOLTAGE
Inverter AC Voltage 270Vac / 300Vac / 330Vac / 360Vac
Output Voltage 10kV-36kV
MV Transformer 250 - 400kVA 400 - 800kVA 800 - 1250kVA
Transformer vector Configuration and type Dyn11, Oil/Dry (optional)
Frequency 50Hz / 60Hz
MV Transformer Efficiency Standard or High Efficiency
MV Switchgear [1] 2L1P scheme, SF6 insulated switchgear
STANDARDSTATION[2]
Concrete Station Dimensions [WxHxD] mm 6080x3200x2530 6950x3200x2530
Inverter ST 6080x3200x2530Transf. ST 4600x3200x2530
Total Weight (Inverter + Concrete) 20t 25tInverter ST 20tTransf. ST 15t
REDUCEDSTATION[2] [3]
Concrete Station Dimensions [WxHxD] mm 6080x2400x2400 6800x2400x2400 8400x2400x2400
Total Weight (Inverter + Concrete) 16t 24t 28t
AUXILIARY SUPPLY
Auxiliary Inverter Power Supply 3 x 400V, 50 / 60Hz, (LVRT compatible inverters equipped with internal UPS)
Auxiliary transformer[4] 10kVA, Yyn0Optional upstream fuse protection
Auxiliary services Station[4] General control panel with auxiliary breakers, prepared with four outputs: Lighting, power supply, inverter power supply and auxiliary MCB
ENVIRON-MENTAL RATINGS
Protection Rating as per EN 60529 Outdoor IP54
Permissible Ambient Temperature -20°C …+50°C
Relative Humidity 5% to 95% Non condensing
Max. Altitude (above sea level) 1000m
Power Altitude derating >1000m, 1% Sn (kVA) per 100m
Noise Level[5] < 79 dBA
UV Exposure Yes
Humidity control Active heating, Optional heating resistor
CABINET FEATURES
Station material Prefabricated Concrete
Concrete (exterior walls) colour RAL 7047
Metal parts (grills, doors) and cover colour RAL 7016
Internal earth grid
Interior lighting
Floor plate and grilles for HE Inverter
Mural type extractor fan with thermostatSecurity features: gloves, bench and first aid informationModule rack trolley for modules replacement
CONNECTIONS
Station Access[4] Input and output holes for underground cabling
High Voltage AC Wiring MV Bridge between transformer and protection switchgear with plug-in terminals at one side and interior terminals in the other
DC Wiring Customised DC fuse protected inputs and disconnectors
AC Auxiliary Services wiringLV Bridge between the transformer and low voltage switchboard included
LV auxiliary services wiring (including those connected to the inverter) included
MV SPECIFICSTANDARDS Medium Voltage Safety EN 62271 - 202, EN 62271 - 200
[1] Two line cells and one protection cell. [2] Dimensions and weight will depend on the final system configuration, please consult Power Electronics.[3] Reduced station frame 3 requires dedicated fundation for underground cabling and transformer oil collection.
[4] Other configuration, please consult Power Electronics.[5] Sound pressure level at a distance of 1m from the rear part.1t=1000kg
NOTES
03.
FR
EE
SUN
HE
S
Freesun HEInverter
DC disconnection and protection cabinet
MV Switchgear
Low voltage and control cabinet
Foundation (optional)[3]
Oil PowerTransformer
[1] It is also available for other Operating Grid Voltage (11kV, 15 kV, 22kV, 24kV, 30kV, 36kV)[2] Other configurations, please consult Power Electronics. Some Freesun HES units may differ from the concept shown in the images. [3] Reduced station require dedicated fundation for underground cabling and transformer oil collection.
NOTES
HES TechnicalCharacteristics
OPERATIONAL DIAGRAM
REDUCED STATION SECTION
LOW
VO
LTAG
E CA
BINE
T
MV
SWIT
CH
GE
AR
AU
X.
TRA
FO
OIL POWERTRANSFORMER
FREESUN HE INVERTER
DC
CA
BIN
ET
FREESUN HE
LV Cabinet
Lig
htin
g
Po
wer
Sup
ply
LV Cabinet
MV TRANSFORMERDyn11
270V-360V / 20kV
270VAC-360VAC / 400V
400VAC + N
Auxiliary transformer
Cir
cuit
bre
aker
OptionalDC disconnection
protection
3~
=
3~
=
3~
=
3~
=
270VAC-360VAC
HE
Co
ntro
l Po
wer
S
upp
ly 40
0VA
C +
N
Lig
htin
g
Po
wer
Sup
ply
MV SWITCHGEAR [2]
MEDIUM VOLTAGE AND INVERTER STATION
[1]
+
-
32_33
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
HETSolar Inverter
34_3534_35
Freesun HET has no boundaries. It eliminates
maritime transport barriers and includes all the electrical
equipment ready for fast comissioning
Freesun HET is a turnkey solution designed for large solar photovoltaic plants under the most demanding environments. It includes a Freesun HE inverter and all the LV and MV electrical equipment ready for fast commissioning.
The unique features of the Freesun HE cooling system in combination with an isolated steel container, optional dust filters or back up air conditioning, make Freesun HET inverter the most suitable solution for worldwide projects under the most demanding operation conditions.
Freesun HET has no boundaries. A standard container eliminates maritime transport barriers and increase competitiveness and reliability to your projects all over the world.
03.
FR
EE
SUN
HE
T
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HET TechnicalCharacteristics
FRAME 3 - FS FRAME 2 TWIN - FS
MEDIUM VOLTAGE
Inverter Output Voltage 270Vac / 300Vac / 330Vac / 360VacOutput Voltage [1] 10kV-36kVInverter 1 x HE Frame 3 2 x HE Frame 2 (TWIN)MV Transformer 800kVA - 1250kVA 1300kVA - 2000kVATransformer vector Configuration Dyn11Transformer Type Dry type - Optional Oil immersed Frequency 50Hz / 60HzMV Transformer Efficiency Standard or High EfficiencyMV Switchgear [1] 2L1P scheme, SF6 insulated switchgear
STATIONContainer 40’ High Cube ISO Container Container Dimensions [WxDxH] mm [2] 12192x2438x2896, 40 feetTotal Weight [2] 18t
AUXILIARY SUPPLY
Auxiliary Inverter Power Supply 3 x 400V, 50 / 60Hz, (LVRT compatible inverters equipped with internal UPS)Auxiliary transformer[3] 10kVA, Yyn0, 270Vac-360Vac / 400Vac
Auxiliary services StationLV panel, Internal earth grid, Interior lighting, Floor plate and grilles for HE inverter, Wall and ceiling insulation, Mural type extractor fan with thermostat, Gloves, bench
and first aid information, Module rack trolley for modules replacementOptional Auxiliary services Door with internal insulation, Door safety opening, Dustproof Filters,Air conditioning
ENVIRON-MENTAL RATINGS
Protection Rating as per EN 60529 Outdoor IP54Permissible Ambient Temperature -20°C …+50°CRelative Humidity, non condensing 5% to 95% Non condensingMax. Altitude (above sea level) 1000mPower Altitude derating >1000m, 1% Sn (kVA) per 100mNoise Level [4] < 79 dBA UV Exposure YesPainting coating C3 (ISO 12944), C5 (Optional)Heating resistors Optional
CABINET FEATURES
Station material 20/10 thick corrugated sheet with load bearing structure and Internal InsulationExterior walls colour RAL 7047Metal parts (grills and doors) and cover colour RAL 7016Internal earth gridInterior lightingFloor plate and grilles for HE InverterWall and ceiling insulationDoor with internal insulation OptionalDoor safety opening OptionalMural type extractor fan with thermostatDustproof Filters OptionalAir conditioning OptionalSecurity features:gloves, bench and first aid informationModule rack trolley for modules replacement
CONNECTIONS
Station Access Input and output holes for underground cabling
High Voltage AC Wiring MV Bridge between transformer and protection switchgear with plug-in terminals at one side and interior terminals in the other
Low Voltage AC WiringMaximum cable section
8x240mm2 M12 per phase4x240mm2 M12 neutral
DC Wiring Customised DC fuse protected inputs and disconnectors
AC Auxiliary Services wiring LV Bridge between the transformer and low voltage switchboard includedLV auxiliary services wiring (including those connected to the inverter) included
SPECIFICSTANDARDS
Medium Voltage Safety EN 62271 - 202, EN 62271 - 200Transportation CSC Safety approval
[1] Two line cells and one protection cell. [2] Dimensions and weight will depend on the final system configuration, please consult Power Electronics.
[3] Other configuration, please consult Power Electronics.[4] Sound pressure level at a distance of 1m from the rear part.1t=1000kg
NOTES
Twin Freesun HEInverters
MV Switchgear
LV Cabinet &Aux. transformer
DC disconnection &protection panel
Dry type Transformer
Aux. equipment
HET TechnicalCharacteristics
OPERATIONAL DIAGRAM
SECTION
[1] It is also available for other Operating Grid Voltage (15 kV, 22kV, 24kV, 30kV, 33kV)
Other configurations, please consult Power Electronics. Some Freesun HET units may differ from the concept shown in the images.
NOTES
LOW
VO
LTA
GE
C
AB
INE
T
AUX.EQUIPMENT
AU
X.
TRA
NS-
FOR
ME
R
MV
SWIT
CH
GE
AR
TRANSFORMER
FREESUN HE INVERTER
DISC
ON
NE
CTIN
G U
NIT
03.
FR
EE
SUN
HE
T
36_37
FREESUN HE
LV Cabinet
Lig
htin
g
Po
wer
Sup
ply
LV Cabinet
MV TRANSFORMERDyn11
270V-360V / 20kV
270VAC-360VAC / 400V
400VAC + N
Auxiliary transformer
Cir
cuit
bre
aker
OptionalDC disconnection
protection
3~
=
3~
=
3~
=
3~
=
270VAC-360VAC
HE
Co
ntro
l Po
wer
S
upp
ly 40
0VA
C +
N
Lig
htin
g
Po
wer
Sup
ply
MV SWITCHGEAR [2]
MEDIUM VOLTAGE AND INVERTER STATION
[1]
+
-
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
OUTDOOR UTILITY SCALESolar Inverters
03.
FR
EE
SUN
38_39
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HECSolar Inverter
40_41
Freesun Gen II - The most powerful and reliable air
cooled utility-scale PV inverter in the market
Power Electronics’ Freesun HEC and HEC+ 2nd generation of outdoor modular and redundant inverters are the most powerful and reliable air cooled Utility Scale PV Inverters in the market. 1000Vdc class upgraded inverters offer extended MPPt voltage range and maximum efficiency in three different AC output voltages 360Vac, 380Vac and 400Vac, covering all commercial and utility-scale PV facilities.
Freesun HEC and HEC+ are based on a modular & redundant topology with up to 10 modules ranging from 150kVA to 170kVA that provides the competiveness of central inverters and the availability of string inverters. The Freesun HEC and HEC+ are featured with an outdoor IP54 stainless steel enclosure, 50mm rockwool isolation panel and the most advance iCOOL filter-less system that makes it suitable for the most demanding conditions.
Freesun HEC can be equipped with customized internal (HEC+) or external DC disconnection and protection subsystem that makes it compatible with any PV plant configuration and the highest DC:AC ratios.
03.
FR
EE
SUN
HE
C
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Freesun HEC topology gets the competiveness of central inverters and the availability of string inverters. It is constructed with independent modules from 150 to 170kVA, each module includes its own control board, power stage and cooling system, being coupled by the DC and AC buses. In the end, an issue only affects to one of the units and never the entire system. At the same time, the power of the faulty module is sent to an adjoining operative module, so that it only reduces the injected power when the maximum rated power is reached. If not, you won’t lose a kWh and you might probably never realize that a module is not operative.
All the units work in parallel together commanded by the master. This master is the main governor of the system and is responsible of the MPPt tracking, synchronization sequence, overall protection…. Freesun HEC is smartly designed to last. The automatic mode shifts every night the master role by comparing the register of energy production of every module. The one with less energy produced (kWh) will act as a master next early morning with the first sunbeams. This feature enables a homogeneous wear and tear of all the components in the modules, extends the product lifetime and MTBF ratio.
Automatic RedundantModular Master Slave System
0 3 5 7 9 11 13 15 17 19 21
1200
900
600
300
1500
AUGUST
SEPTEMBER
PO
WE
R (
KW
)
TIME (h)
Available solar Power (kW)Freesun Production (kW) -1 Module faultCompetitors Production (kW) -1 Module fault
4:25
10kW
4:354:30
5kW
15kW
4:20 4:40
August saved Energy (kWh)September saved Energy (kWh)
42_43
03.
FR
EE
SUN
HE
C
When addressing the selection of a solar inverter manufacturer, there are crucial points that should be considered first and inverter’s efficiency is one of the most important. On low radiation conditions, a modular inverter operates at higher efficiency levels than a similarly sized central inverter. By shutting off unneeded power modules, modules load increases to get the maximum available efficiency. At the same time, a lower power rating of the inverter units allow to start feed-in earlier in the morning and to stop later in the afternoon. As a result, throughout the entire service life of the PV plant, HEC will generate higher yields than central or string inverters.
EF
FIC
IEN
CY
POWER
A MODULAR AND REDUNDANT INVERTER GENERATES
HIGHER YIELDS
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Freesun HEC inverters have been designed to last over 20 years of operation under harsh environments and extreme weather conditions. HEC units are ready and tested to withstand from the frozen Canadian landfills to the extreme African dessert conditions featuring:
• Totally sealed area protects electronics from dust and moisture.• Conformal coating on electronic board shields PCBs from aggressive atmospheres.• Temperature and humidity controlled active heating prevents from internal water condensation.• Stainless Steel construction with 2mm thickness for maximum enclosure longevity • Corrosion proved polymeric painting C3 according to ISO 9223 used in the most demanding environments• 50mm rockwool panel isolates the cabinet from solar heat gains. • Roof cover design dissipates solar radiation, reduces heat build-up and avoids water leakages. Additionally you will be able to protect your O&M team from rain or sun by installing our corrugated iron roof or retractable awning kit. The solid HEC structure avoids the need of additional external structures. • Random units from a lot pass Factory Water Tightness Test ensuring product quality.
Rugged design
Rockwool panel Stainless SteelPolymeric painting
Freesun HEC is available with internal DC disconnection and protection subsystem (HEC+) or with an external DC disconnection and protection unit (DU unit) that will be coupled together with the inverter by a mounting kit. The DC subsystems are fully customizable and can be featured with up to 6 DC on-load disconnectors, 36 fuses and 24 independent monitoring channels.
The disconnecting unit goes one step further by improving the PV plant safety and operation for those who apply the best engineering.
DC Disconnection & Protection
03.
FR
EE
SUN
HE
C
In Power Electronics we don’t believe in cost cutting when it affects the quality of the product and that’s why we oversize sensitive components and improve the sophisticated iCOOL performance that allow HEC to work at 50°C with no power derating. Our know how in mining, water treatment plants, CSP facilities in the most demanding locations all over the world have given us the necessary experience to develop the perfect technical solution for our outdoor solar inverters.
Freesun HEC modules are divided into two main areas: clean area (electronics) and hot area (filters and heat sink). The electronics are totally sealed and use a temperature control low flow cooling system that reduces filters clogging and maintenance intervals. The hot area integrates independent and speed controlled fans per each module, reducing to the maximum the Stand-by consumption at low capacity and boosting the cooling capacity for PV installation situated at higher altitudes than 3000 meters above sea level.
Using the latest modulation techniques, inspired by the most accurate and powerful motor control applications, has lead to the widest MPPt full power window in the solar market. Update your OND files as soon as possible to check how the most advanced control software and our unique topology boost your PV plant performance rates.
iCool
MAXIMUM YIELD AND RELIABILITY
Electronics
Filters and Heat sinks
44_45
400VAC - MPPt Window 566V-900VFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS FRAME 4 - FS
NUMBER OF MODULES 3 4 5 6 7 8 9 10
REFERENCE FS0450CH FS0601CH FS0751CH FS0901CH FS1050CH FS1200CH FS1350CH FS1500CH
OU
TPU
T
AC Output Power(kVA) @ 50°C 450 600 750 900 1050 1200 1350 1500AC Output Power(kVA) @ 40°C 510 680 850 1020 1190 1360 1530 1700Rated AC Output Current (A) @40°C 736 981 1227 1472 1718 1963 2208 2454Operating Grid Voltage(VAC) 400VacOperating Range, Grid Frequency 50Hz/60HzCurrent Harmonic Distortion (THDi) < 3% at any load conditionPower Factor (cosine phi)[1] 0.00 leading … 0.00 lagging adjustable/ Reactive Power injection at night Power Curtailment (kVA) 0...100%/0.1% Steps
INP
UT
MPPt Voltage Window (VDC)[2] 566V - 900VMPPt window @full power (VDC)[3] 580V – 820VMaximum DC and Starting voltage 1000VMaximum DC current (A) 900 1200 1500 1800 2100 2400 2700 3000Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%
EFF
ICIE
NC
Y &
AU
XIL
IAR
Y
SUP
PLY
Euroeta (η) 98.2% 98.3% 98.4% 98.4%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power Supply 10kVA Built-in Internal transformer as standard220VAC–5kVA user power supply available
UPS backup system Optional 400V- 700VAh Internal UPS-(LVRT compatible units are equipped as standard)Avg. Power Consumption 1380W 1840W 2300W 2760W 3220W 3680W 4140W 4600W
CA
BIN
ET Dimensions [WxDxH] [4] [mm] 2900x1050x2400 3900x1050x2400 4900x1050x2400 5900x1050x2400
Weight (kg) [5] 2470 2780 3540 3850 4590 4900 5640 5950Air Flow Intake through lower part blown out through upper sideType of ventilation Forced air cooling
EN
VIR
ON
-M
EN
T
Degree of protection IP54Permissible Ambient Temperature -20°C to +50°CRelative Humidity 4% to 100% CondensingMax. Altitude (above sea level) 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[6] < 70 dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App display or Web displayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 / Modbus RTUPlant Controller Communication Ethernet / Modbus TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Protection Floating PV array: Isolation Monitoring per MPPGrounded PV array (Positive pole and negative pole): GFDI protection per MPP
Humidity control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC switch and fuses
General DC Protection & Disconn. Optional External Disconnecting Unit Cabinet(DC fuse protection and on-load disconnector with external operating handle)
Module AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. DC contactor & DC fuses Overvoltage Protection DC and AC Inverter sides (Type 4) and Auxiliary Supply type 2 - Internal StandardProtection class Class ILightning Protections Optional (Integrated in the inverter)
[1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00•Vac nom and cos Ф= 1. Consult Power Electronics for derating curves.[3] Values at 1.00•Vac nom, cos Ф= 1, TAMB = 40°C [4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary, consult Power Electronics.[6] Sound pressure level at a distance of 1m from the rear part.
HEC TechnicalCharacteristics 400VAC
FREESUN SOLAR INVERTER / POWER ELECTRONICS
380VAC - MPPt Window 538V-900VFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS FRAME 4 - FS
NUMBER OF MODULES 3 4 5 6 7 8 9 10
REFERENCE FS0435CH FS0580CH FS0725CH FS0870CH FS1015CH FS1160CH FS1305CH FS1450CH
OU
TPU
T
AC Output Power(kVA) @ 50°C 435 580 725 870 1015 1160 1305 1450AC Output Power(kVA) @ 40°C 480 640 800 960 1120 1280 1440 1600Rated AC Output Current (A) @40°C 729 972 1215 1459 1702 1945 2188 2431Operating Grid Voltage(VAC) 380Vac Operating Range, Grid Frequency 50Hz/60HzCurrent Harmonic Distortion (THDi) < 3% at any load conditionPower Factor (cosine phi)[1] 0.00 leading … 0.00 lagging adjustable/ Reactive Power injection at night Power Curtailment (kVA) 0...100%/0.1% Steps
INP
UT
MPPt Voltage Window (VDC)[2] 538V - 900VMPPt window @full power (VDC)[3] 544V – 820VMaximum DC and Starting voltage 1000VMaximum DC current (A) 900 1200 1500 1800 2100 2400 2700 3000Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%
EFF
ICIE
NC
Y &
AU
XIL
IAR
Y
SUP
PLY
Euroeta (η) 98.2% 98.3% 98.4% 98.4%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power Supply 10kVA Built-in Internal transformer as standard220VAC–5kVA user power supply available
UPS backup system Optional 400V- 700VAh Internal UPS-(LVRT compatible units are equipped as standard)Avg. Power Consumption 1380W 1840W 2300W 2760W 3220W 3680W 4140W 4600W
CA
BIN
ET Dimensions [WxDxH] [4] [mm] 2900x1050x2400 3900x1050x2400 4900x1050x2400 5900x1050x2400
Weight (kg) [5] 2470 2780 3540 3850 4590 4900 5640 5950Air Flow Intake through lower part blown out through upper sideType of ventilation Forced air cooling
EN
VIR
ON
-M
EN
T
Degree of protection IP54Permissible Ambient Temperature -20°C to +50°CRelative Humidity 4% to 100% CondensingMax. Altitude (above sea level) 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[6] < 70 dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App display or Web displayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 / Modbus RTUPlant Controller Communication Ethernet / Modbus TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Protection Floating PV array: Isolation Monitoring per MPPGrounded PV array (Positive pole and negative pole): GFDI protection per MPP
Humidity control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC switch and fuses
General DC Protection & Disconn. Optional External Disconnecting Unit Cabinet(DC fuse protection and on-load disconnector with external operating handle)
Module AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. DC contactor & DC fuses Overvoltage Protection DC and AC Inverter sides (Type 4) and Auxiliary Supply type 2 - Internal StandardProtection class Class ILightning Protections Optional (Integrated in the inverter)
[1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00•Vac nom and cos Ф= 1. Consult Power Electronics for derating curves.[3] Values at 1.00•Vac nom, cos Ф= 1, TAMB = 40°C [4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary, consult Power Electronics.[6] Sound pressure level at a distance of 1m from the rear part.
HEC TechnicalCharacteristics 380VAC
46_47
HEC TechnicalCharacteristics 360VAC
FREESUN SOLAR INVERTER / POWER ELECTRONICS
360VAC - MPPt Window 510V-900VFRAME 1 - FS FRAME 2 - FS FRAME 3 - FS FRAME 4 - FS
NUMBER OF MODULES 3 4 5 6 7 8 9 10
REFERENCE FS0420CH FS0560CH FS0702CH FS0840CH FS0980CH FS1120CH FS1260CH FS1400CH
OU
TPU
T
AC Output Power(kVA) @ 50°C 420 560 700 840 980 1120 1260 1400AC Output Power(kVA) @ 40°C 450 600 750 900 1050 1200 1350 1500Rated AC Output Current (A) @40°C 722 962 1203 1443 1684 1925 2165 2406Operating Grid Voltage(VAC) 360VacOperating Range, Grid Frequency 50Hz/60HzCurrent Harmonic Distortion (THDi) < 3% at any load conditionPower Factor (cosine phi)[1] 0.00 leading … 0.00 lagging adjustable/ Reactive Power injection at nightPower Curtailment (kVA) 0...100%/0.1% Steps
INP
UT
MPPt Voltage Window (VDC)[2] 510V - 900VMPPt window @full power (VDC)[3] 510V – 820VMaximum DC and Starting voltage 1000VMaximum DC current (A) 900 1200 1500 1800 2100 2400 2700 3000Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%
EFF
ICIE
NC
Y
& A
UX
ILIA
RY
SU
PP
LY
Euroeta (η) 98.2% 98.3% 98.4% 98.4%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power Supply 10kVA Built-in Internal transformer as standard220VAC–5kVA user power supply available
UPS backup system Optional 400V- 700VAh Internal UPS-(LVRT compatible units are equipped as standard)Avg. Power Consumption 1380W 1840W 2300W 2760W 3220W 3680W 4140W 4600W
CA
BIN
ET Dimensions [WxDxH] [4] [mm] 2900x1050x2400 3900x1050x2400 4900x1050x2400 5900x1050x2400
Weight (kg) [5] 2470 2780 3540 3850 4590 4900 5640 5950Air Flow Intake through lower part blown out through upper sideType of ventilation Forced air cooling
EN
VIR
ON
-M
EN
T
Degree of protection IP54Permissible Ambient Temperature -20°C to +50°CRelative Humidity 4% to 100% CondensingMax. Altitude (above sea level) 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[6] < 70dBA
CO
NTR
OL
INTE
RFA
CE
Interface Alphanumeric Display / Optional Freesun App display or Web displayCommunication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100String Supervisor Communication RS485 / Modbus RTUPlant Controller Communication Ethernet / Modbus TCP/IPDigital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault Protection Floating PV array: Isolation Monitoring per MPPGrounded PV array (Positive pole and negative pole): GFDI protection per MPP
Humidity control Active Heating / Optional Heating ResistorsEmergency Stop OptionalGeneral AC Protection & Disconn. Circuit Breaker / Optional AC switch and fuses
General DC Protection & Disconn. Optional External Disconnecting Unit Cabinet(DC fuse protection and on-load disconnector with external operating handle)
Module AC Protection & Disconn. AC circuit breaker & contactorModule DC Protection & Disconn. DC contactor & DC fuses Overvoltage Protection DC and AC Inverter sides (Type 4) and Auxiliary Supply type 2 - Internal StandardProtection class Class ILightning Protections Optional (Integrated in the inverter)
[1] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2)[2] Values at 1.00•Vac nom and cos Ф= 1. Consult Power Electronics for derating curves.[3] Values at 1.00•Vac nom, cos Ф= 1, TAMB = 40°C [4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary, consult Power Electronics.[6] Sound pressure level at a distance of 1m from the rear part.
48_49
HEC Dimensions
FRAME 1 FRAME 2
FRAME 3
FRAME 45900
240
0
240
0
4900
240
0
3900
240
0
2900
FREESUN SOLAR INVERTER / POWER ELECTRONICS
DimensionsHEC+
FRAME 1
FRAME 2
FRAME 35900
240
0
240
0
4900
240
0
3900
03.
FR
EE
SUN
HE
C
50_51
HEC Efficiency curvesOperational Diagram
EFFICIENCY CURVES
OPERATIONAL DIAGRAM
1 Module
3 Modules
4 Modules
7 Modules
9 Modules
10 Modules
e (%
)
P / Pnom (%)
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%84
86
88
90
92
94
96
98
E�ciency curves from 1 to 10 100 kVA modules, 550 Vdc.Consult Power Electronics for other configurations.
+
-
DC
BUSAC
CONTACTOR
T(ºC)
A
360-
400V
AC
BU
S
M1.1
(+)
UP
TO
10
MODULES
CA
NC
OM
MU
NIC
ATI
ON
SY
NC
HR
ON
IZA
TIO
N
DC
BUSAC
CONTACTOR
M1.2
(+)
M1.n
(+)
M1.1
(-)M1.2
(-)
M1.n
(-)
T(ºC)
A A
A
M10M10
M10
M10
M10
M10
.1
(+).2
(+)
.n
(+)
.1
(-)
.2
(-)
.n
(-)
ETH
ER
NE
TC
OM
MU
NIC
ATI
ON
ETHERNET
SWITCH
OVERVOLTAGE
PROTECT ON[2]
RS485
RS485
A
A
A
A
+
-
CONTROL
CONTROL
STRING SUPERVISOR
METEO - STATIONPOWER PLANT CONTROLLER
Communication Ports: RS485, RS232, USB
Analogue and Digital E/S
GROUND FAULT PROTECTION[1]
MO
DU
LAR
MP
Pt D
C B
US
UP
TO 4
MP
Pt
DC CONTACTORAND FUSES
DC CONTACTORAND FUSES
INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
STIN
U G
NITCE
NN
OCSID
)LA
NOITP
O(
CIRCUIT BREAKER
R
S
T
400V
AC
PO
WER
SOU
RO
ptio
nal
CE
5kVA
PE
OVERVOLTAGEPROTECTION[2]
L1
L2
L3 360
– 40
0VA
CO
UTP
UT
POW
ER
OVERVOLTAGEPROTECTION
AUXILIARTRANSFORMER
FUSEPROTECTION
EM
C F
ILTE
R
Aux
iliar
y Po
wer
SU
pply
400
VAC
FUSES ON-LOADDISCONNECTOR
FUSES ON-LOADDISCONNECTOR
INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
EM
RET
LIF
C
R
S
TPE
400V
AC
EX
TER
NA
LPO
WER
SU
PPLY
EM
CFI
LTE
RE
MC
FILT
ER
360-400Vac
(OPT
ION
AL)
MODULE 10
WIFI
FREESUN DATA CENTER
FREESUN APP DISPLAY
FREESUN WEB DISPLAY
[1] In positive pole or negative pole earth connected installations, the protection must be disconnected.[2] Optional AC and DC lightning protection.
MODULE 1
FREESUN SOLAR INVERTER / POWER ELECTRONICS
MV COMPACTSTATIONSolar Station
FREESUN SOLAR INVERTER / POWER ELECTRONICS
MV COMPACTSTATION
The Freesun MV compact station is your right choice to
house indoor equipment
The Freesun MV compact station is turnkey concrete compartment for large installation ready to connect up to two Freesun HEC inverters and the MV cables. It can house inside an oil-immersed step-up transformer and SFS6 gas insulated switchgear, nevertheless it can be customized to fit client’s indoor special equipment. Reduce the LCOE by installing new cost-effective solutions that ensures the maximum yield and availability.
03.
FR
EE
SUN
MV
CO
MPA
CT
STA
TIO
N
52_53
FREESUN SOLAR INVERTER / POWER ELECTRONICS
MV COMPACT STATIONTechnical Characteristics
MV COMPACT STATION
MEDIUM VOLTAGE
Input Voltage 360Vac / 380Vac / 400Vac
Number of Inverters connected Max. 2 Freesun units - Double or Triple winding transformer available[1]
Output Voltage 10kV – 36kV
MV Transformer 250kVA - 2000kVA
Transformer vector Configuration Dyn11 oil/dry (optional)
Frequency 50Hz / 60Hz
MV Transformer efficiency Standard or High efficiency
MV Switchgear 2L1P scheme, SF6 insulated switchgear
STATION DATAConcrete Cabinet Dimensions [WxHxD] mm[2] 4600x3200x2530
Total Weight[2] 15t
AUXILIARY SUPPLY
Auxiliary Station transformer [3]
360Vac-380Vac-400Vac / 400V, 50/60Hz
10kVA – 30kVA, Yyn0
Optional upstream fuse and downstream circuit breaker protection
Auxiliary services CabinetGeneral control panel with auxiliary breakers, prepared with four
outputs: Lighting, power supply, inverter power supply and auxiliary MCB Optional UPS systems (Low Voltage Ride Through option)
ENVIRON-MENTAL RATINGS
Protection Rating as per EN 60529 Outdoor IP54
Permissible Ambient Temperature -20°C …+50°C
Relative Humidity, non-condensing 5% to 95% Non condensing
Max. Altitude (above sea level) [3] 1000m
Power Altitude derating >1000m, 1% Sn (kVA) per 100m
UV Exposure Yes
Heating Resistors Optional
CABINET FEATURES
Cabinet material Prefabricated Concrete
Concrete (exterior walls) colour [3] RAL 7047
Metal parts (grills and doors) and cover colour [3] RAL 7016
Internal earth grid
Interior lighting
Mural type extractor fan with thermostatSecurity features: gloves, bench and first aid information
CONNECTIONS
Cabinet Access Input and output holes for underground cabling
High Voltage AC Wiring MV Bridge between transformer and protection switchgear with plug-in terminals at one side and interior terminals in the other
Low Voltage AC Wiring[3] LV Bridge between the inverter and MV Compact Station not includedMaximum cable section: 8x240mm2 M12 per phase; 4x240mm2 M12 neutral
Auxiliary Power Supply [3]
LV auxiliary services wiring within the station includedLV bridge between MV Compact station’s auxiliary services cabinet and the
Inverter not includedMV SPECIFICSTANDARDS Medium Voltage Safety EN 62271 – 202, EN 62271 – 200
[1] Consult Power Electronics for additional information.[2] Dimensions and weight will depend on the final system configuration, please consult Power Electronics.[3] Other configuration available, please consult Power Electronics.
NOTES
54_55
OPERATIONAL DIAGRAM
FULL SET SECTION
03.
FR
EE
SUN
MV
CO
MPA
CT
STA
TIO
N
LV Cabinet
MV TRANSFORMERDyn11
/ 20kV
/ 400V
10kVA, Dyn11
400VAC + N
Auxiliary transformer
Fuses andOn-Load Disconnector [1]
360Vac-400Vac
360Vac-400Vac
360Vac-400Vac
Lighting
Po
wer S
upp
ly
MV SWITCHGEAR
MV COMPACT STATION
[1]
LV Switchboard
MV Switchgear
Auxiliary station transformerPower transformer
[1] It is also available for other Operating Grid Voltage (11kV, 15 kV, 22kV, 24kV, 30kV, 36kV)[2] Other configurations, please consult Power Electronics. Some MV Compact stations may differ from the concept shown in the images.
NOTES
MV COMPACT STATIONFREESUN HEC INVERTER
FREESUN SOLAR INVERTER / POWER ELECTRONICS
MV OUTDOORSETSolar Set
FREESUN SOLAR INVERTER / POWER ELECTRONICS
MV OUTDOORSET
Freesun MV outdoor kit offer flexibility and competiveness to
reduce your investment
The Freesun MV Outdoor kit is a cost effective solution for Freesun HEC, that comprises an outdoor MV step-up oil-immersed transformer and an indoor SF6 gas insulated MV switchgear fitted in an outdoor concrete cubicle. Three outdoor items offers the most competitive solution.
03.
FR
EE
SUN
MV
OU
TDO
OR
SE
T
56_57
FREESUN SOLAR INVERTER / POWER ELECTRONICS
MV OUTDOOR SETTechnical Characteristics
MV OUTDOOR SET
POWER TRANSFORMER
Input Voltage 360Vac / 380Vac / 400Vac
Output Voltage 10kV - 36kV
MV Transformer 250kVA -2000kVA
Transformer vector Configuration Dyn11 biodegradable oil (optional)
Frequency 50Hz / 60Hz
MV Transformer efficiency Standard or High efficiency
I/O connections water protection
Transformer cabling Customized connections busbar and cable glands
MEDIUM VOLTAGE
SWITCHBOARD
Configuration 2L1P 2L2P, 1L2P
Max Power Transformers Connection 1 2 2
Type SF6 insulated switchgear
Insulation Level 28 / 75 kV; 38 / 95 kV; 50 / 125 kV; 70 / 170 kV
Rated Current 630 / 1250 A
Short time withstand current 16 kA / 3 s; 20 kA / 1 s
Cabinet Dimensions [WxHxD] mm 2290x2080x1340
Total Weight [1] 4.5t
Station material Prefabricated Concrete
Concrete (exterior walls) colour[2] RAL 7047Security features: gloves, bench and first aid informationCabinet cabling Input and output holes for underground cabling
ENVIRON-MENTAL RATINGS
Protection Rating as per EN 60529 Outdoor IP54
Permissible Ambient Temperature -20°C …+50°C
Relative Humidity, non-condensing 4% to 95% Non condensing
Max. Altitude (above sea level) [2] 1000m
Power Altitude derating >1000m, 1% Sn (kVA) per 100m
UV Exposure Yes
OTHERLV and MV Cabling Optional
LV AC overcurrent protection Circuit breaker built-in in HEC
MV SPECIFICSTANDARDS Medium Voltage Safety EN 62271 – 202, EN 62271 – 200
[1] Weight will depend on the final system configuration, please consult Power Electronics.[2] Other configuration available, please consult Power Electronics.
NOTES
58_59
OPERATIONAL DIAGRAM
03.
FR
EE
SUN
MV
OU
TDO
OR
SE
T
FREESUN HECDU
3~
=
3~
=
3~
=
3~
=
360Vac-400Vac360V-400V/20kV
MV Outdoor Set
+
-
MV TRANSFORMER MV SWITCHGEAR
Dyn11[1]
FULL SET SECTION
[1] It is also available for other Operating Grid Voltage (11kV, 15 kV, 22kV, 24kV, 30kV, 36kV)[2] Other configurations, please consult Power Electronics. Some MV Compact stations may differ from the concept shown in the images.
NOTES
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HEC-ULSolar Inverter
60_61
A modular and redundat system maximizes plant’s
availability and performance
Freesun HEC–UL is the unique outdoor modular central inverter in North America’s market. It integrates built-in as standard the unique ARM2S2, iCOOL – filterless and Multi MPPt systems that maximize plant’s availability and performance.
Freesun HEC–UL MW inverter has been designed for utility scale PV plants with the most demanding environments. The Disconnecting Unit makes HEC-UL to comply with UL1741, IEEE1547 and NEC2011 installation requirements.
It includes Freesun’s proven dynamic grid support features such as Low and High Voltage Ridethrough and regulation (LVRT & OVRT, VRS), Frequency Ridethrough and regulation (FRT, FRS), Power factor and Reactive power injection control, Ramp Rate Control (RRC), that enhance grid quality and PV plant management.
Freesun HEC–UL is available in a turnkey MW platform Freesun HEK. Delivered with factory tested Inverter, MV Pad-mount transformer and auxiliary equipment that reduce installing and commissioning time and cost.
03.
FR
EE
SUN
HE
C-U
L
[[1] Values at 50°C.[2] Maximum ambient temperature 40°C.[3] Values at 1.00·Vac nom and cos Ф = 1.[4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary. Consult Power Electronics.[6] Other characteristics consult with Power Electronics.[7] Sound pressure level at a distance of 1m from the rear part.
HEC-UL TechnicalCharacteristics 390VAC
390VAC - MPPt range 585Vdc-820VdcFRAME 0 - FS FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8
FREESUN MODEL NUMBER FS0300CU FS0450CU FS0600CU FS0751CU FS0900CU FS1050CU FS1200CU
OU
TPU
T
Continuous AC Output Power (kVA) [1] 300 450 600 750 900 1050 1200Max. apparent Power (+10%) (kVA) [2] 330 495 660 825 990 1155 1320Continuous Output AC Current(A) 444 666 888 1110 1332 1554 1776Operating Grid Voltage(VAC) 390VacOperating Range, Grid Frequency 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cos phi)/@max. power 0.0 leading...0.0 lagging / 0.90 leading … 0.90 lagging (adjustable)Power Curtailment (kVA) 0...110%/0.1% Steps
INP
UT MPPt Range (VDC)[3] 585V-820V
Max. permissible DC voltage 1000VMax. continuous DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000AMax. short circuit DC current (A) 650A 975A 1300A 1625A 1950A 2275A 2600A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY
Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%Weighted CEC Efficiency (η) 98.0% 98.0% 98.0% 98.0%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power SupplyBuilt-in Internal transformer as standard
(Optional external 3x208VAC power supply and UPS backup system)Avg. Power Consumption 920W 1380W 1840W 2300W 2760W 3220W 3680W
CA
BIN
ET
Dimensions [WxDxH] mm
mm[4] 1900x1020x2400 2900x1020x2400 3900x1020x2400 4900x1020x2400inches[4] 74.8 x 40.2 x 94.5 114.2x 40.2 x 94.5 153.5 x 40.2 x 94.5 192.9 x 40.2 x 94.5
Weight[5] kg 1720 2780 3850 4900lbs 3800 6130 8500 10800
Air Flow Intake through lower part blown out through upper sideType of ventilation Forced
EN
VIR
ON
-M
EN
T
Degree of protection NEMA 3RPermissible Ambient Temperature[6] -4° F to +122° F / -20°C …+50°CRelative Humidity 4% to 100%Max. Altitude (above sea level)[6] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[7] < 70 dBA
CO
NTR
OL
INTE
RFA
CE Interface Alphanumeric display
Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100Digital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault ProtectionFloating PV array: Isolation Monitoring per MPP
Grounded PV array (Positive pole and negative pole): GFDI protection per MPPHeating Resistors StandardEmergency Stop OptionalGeneral AC Circuit Breaker Standard; External OperationAC contactor Standard in each moduleAC Circuit Breaker Standard in each moduleDC Contactor Standard in each moduleDC Fuses Standard in each module
General DC protection Optional Disconnecting Unit Cabinet
(DC fuse protection and on-load disconnector with external operating handle)Overvoltage Protection DC and AC Inverter sides ( Type 4) and Auxiliary Supply type 2- Internal StandardLightning Protections Optional (Integrated in the inverter)
360VAC - MPPt range 540Vdc-820VdcFRAME 0 - FS FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8
FREESUN MODEL NUMBER FS0280CU FS0420CU FS0560CU FS0701CU FS0830CU FS0970CU FS1110CU
OU
TPU
T
Continuous AC Output Power (kVA)[1] 280 420 560 700 830 970 1110Max. apparent Power (+10%) (kVA)[2] 310 460 610 760 920 1070 1220Continuous Output AC Current(A) 444 667 889 1111 1333 1555 1778Operating Grid Voltage(VAC) 360VacOperating Range, Grid Frequency 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cos phi)/@max. power 0.0 leading...0.0 lagging / 0.90 leading … 0.90 lagging (adjustable)Power Curtailment (kVA) 0...110%/0.1% Steps
INP
UT MPPt Range (VDC)[3] 540V-820V
Max. permissible DC voltage 1000VMax. continuous DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000AMax. short circuit DC current (A) 650A 975A 1300A 1625A 1950A 2275A 2600A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY
Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%Weighted CEC Efficiency (η) 98.0% 98.0% 98.0% 98.0%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power SupplyBuilt-in Internal transformer as standard
(Optional external 3x208VAC power supply and UPS backup system)Avg. Power Consumption 920W 1380W 1840W 2300W 2760W 3220W 3680W
CA
BIN
ET
Dimensions [WxDxH] mm
mm[4] 1900x1020x2400 2900x1020x2400 3900x1020x2400 4900x1020x2400inches[4] 74.8 x 40.2 x 94.5 114.2x 40.2 x 94.5 153.5 x 40.2 x 94.5 192.9 x 40.2 x 94.5
Weight[5] kg 1720 2780 3850 4900lbs 3800 6130 8500 10800
Air Flow Intake through lower part blown out through upper sideType of ventilation Forced
EN
VIR
ON
-M
EN
T
Degree of protection NEMA 3RPermissible Ambient Temperature[6] -4° F to +122° F /-20°C …+50°CRelative Humidity 4% to 100%Max. Altitude (above sea level)[6] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[7] < 70 dBA
CO
NTR
OL
INTE
RFA
CE Interface Alphanumeric display
Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100Digital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault ProtectionFloating PV array: Isolation Monitoring per MPP
Grounded PV array (Positive pole and negative pole): GFDI protection per MPPHeating Resistors StandardEmergency Stop OptionalGeneral AC Circuit Breaker Standard; External OperationAC contactor Standard in each moduleAC Circuit Breaker Standard in each moduleDC Contactor Standard in each moduleDC Fuses Standard in each module
General DC protection Optional Disconnecting Unit Cabinet
(DC fuse protection and on-load disconnector with external operating handle)Overvoltage Protection DC and AC Inverter sides ( Type 4) and Auxiliary Supply type 2- Internal StandardLightning Protections Optional (Integrated in the inverter)
FREESUN SOLAR INVERTER / POWER ELECTRONICS
03.
FR
EE
SUN
HE
C-U
L
[[1] Values at 50°C.[2] Maximum ambient temperature 40°C.[3] Values at 1.00·Vac nom and cos Ф = 1.[4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary. Consult Power Electronics.[6] Other characteristics consult with Power Electronics.[7] Sound pressure level at a distance of 1m from the rear part.
HEC-UL TechnicalCharacteristics 360VAC
360VAC - MPPt range 540Vdc-820VdcFRAME 0 - FS FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8
FREESUN MODEL NUMBER FS0280CU FS0420CU FS0560CU FS0701CU FS0830CU FS0970CU FS1110CU
OU
TPU
T
Continuous AC Output Power (kVA)[1] 280 420 560 700 830 970 1110Max. apparent Power (+10%) (kVA)[2] 310 460 610 760 920 1070 1220Continuous Output AC Current(A) 444 667 889 1111 1333 1555 1778Operating Grid Voltage(VAC) 360VacOperating Range, Grid Frequency 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cos phi)/@max. power 0.0 leading...0.0 lagging / 0.90 leading … 0.90 lagging (adjustable)Power Curtailment (kVA) 0...110%/0.1% Steps
INP
UT MPPt Range (VDC)[3] 540V-820V
Max. permissible DC voltage 1000VMax. continuous DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000AMax. short circuit DC current (A) 650A 975A 1300A 1625A 1950A 2275A 2600A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY
Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%Weighted CEC Efficiency (η) 98.0% 98.0% 98.0% 98.0%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power SupplyBuilt-in Internal transformer as standard
(Optional external 3x208VAC power supply and UPS backup system)Avg. Power Consumption 920W 1380W 1840W 2300W 2760W 3220W 3680W
CA
BIN
ET
Dimensions [WxDxH] mm
mm[4] 1900x1020x2400 2900x1020x2400 3900x1020x2400 4900x1020x2400inches[4] 74.8 x 40.2 x 94.5 114.2x 40.2 x 94.5 153.5 x 40.2 x 94.5 192.9 x 40.2 x 94.5
Weight[5] kg 1720 2780 3850 4900lbs 3800 6130 8500 10800
Air Flow Intake through lower part blown out through upper sideType of ventilation Forced
EN
VIR
ON
-M
EN
T
Degree of protection NEMA 3RPermissible Ambient Temperature[6] -4° F to +122° F /-20°C …+50°CRelative Humidity 4% to 100%Max. Altitude (above sea level)[6] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[7] < 70 dBA
CO
NTR
OL
INTE
RFA
CE Interface Alphanumeric display
Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100Digital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault ProtectionFloating PV array: Isolation Monitoring per MPP
Grounded PV array (Positive pole and negative pole): GFDI protection per MPPHeating Resistors StandardEmergency Stop OptionalGeneral AC Circuit Breaker Standard; External OperationAC contactor Standard in each moduleAC Circuit Breaker Standard in each moduleDC Contactor Standard in each moduleDC Fuses Standard in each module
General DC protection Optional Disconnecting Unit Cabinet
(DC fuse protection and on-load disconnector with external operating handle)Overvoltage Protection DC and AC Inverter sides ( Type 4) and Auxiliary Supply type 2- Internal StandardLightning Protections Optional (Integrated in the inverter)
62_63
HEC-UL TechnicalCharacteristics 330VAC
330VAC - MPPt range 500Vdc-820VdcFRAME 0 - FS FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8
FREESUN MODEL NUMBER FS0250CU FS0380CU FS0501CU FS0630CU FS0750CU FS0880CU FS1001CU
OU
TPU
T
Continuous AC Output Power (kVA) [1] 250 380 500 630 750 880 1000Max. apparent Power (+10%) (kVA)[2] 280 410 550 690 830 960 1100Continuous Output AC Current(A) 438 656 875 1094 1313 1532 1750Operating Grid Voltage(VAC) 330VacOperating Range, Grid Frequency 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cos phi)/@max. power 0.0 leading...0.0 lagging / 0.90 leading … 0.90 lagging (adjustable)Power Curtailment (kVA) 0...110%/0.1% Steps
INP
UT MPPt Range (VDC)[3] 500V-820V
Max. permissible DC voltage 1000VMax. continuous DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000AMax. short circuit DC current (A) 650A 975A 1300A 1625A 1950A 2275A 2600A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY
Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%Weighted CEC Efficiency (η) 98.0% 98.0% 98.0% 98.0%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power SupplyBuilt-in Internal transformer as standard
(Optional external 3x208VAC power supply and UPS backup system)Avg. Power Consumption 920W 1380W 1840W 2300W 2760W 3220W 3680W
CA
BIN
ET
Dimensions [WxDxH] mm
mm[4] 1900x1020x2400 2900x1020x2400 3900x1020x2400 4900x1020x2400inches 74.8 x 40.2 x 94.5 114.2x 40.2 x 94.5 153.5 x 40.2 x 94.5 192.9 x 40.2 x 94.5
Weight[5] kg 1720 2780 3850 4900lbs 3800 6130 8500 10800
Air Flow Intake through lower part blown out through upper sideType of ventilation Forced
EN
VIR
ON
-M
EN
T
Degree of protection NEMA 3RPermissible Ambient Temperature[6] -4° F to +122° F / -20°C …+50°CRelative Humidity 4% to 100%Max. Altitude (above sea level)[6] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[7] < 70 dBA
CO
NTR
OL
INTE
RFA
CE Interface Alphanumeric display
Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)
Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100
Digital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault ProtectionFloating PV array: Isolation Monitoring per MPP
Grounded PV array (Positive pole and negative pole): GFDI protection per MPPHeating Resistors StandardEmergency Stop OptionalGeneral AC Circuit Breaker Standard; External OperationAC contactor Standard in each moduleAC Circuit Breaker Standard in each moduleDC Contactor Standard in each moduleDC Fuses Standard in each module
General DC protection Optional Disconnecting Unit Cabinet
(DC fuse protection and on-load disconnector with external operating handle)Overvoltage Protection DC and AC Inverter sides ( Type 4) and Auxiliary Supply type 2- Internal StandardLightning Protections Optional (Integrated in the inverter)
208VAC - MPPt range 330Vdc-600VdcFRAME 0 - FS FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8
FREESUN MODEL NUMBER FS0160CU FS0240CU FS0320CU FS0400CU FS0480CU FS0560CU FS0640CU
OU
TPU
T
Continuous AC Output Power (kVA)[1] 160 240 320 400 480 560 640Max. apparent Power (+10%) (kVA)[2] 176 264 352 440 528 616 704Continuous Output AC Current(A) 444 666 888 1110 1332 1554 1776Operating Grid Voltage(VAC) 208VacOperating Range, Grid Frequency 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cos phi)/@max. power 0.0 leading...0.0 lagging / 0.90 leading … 0.90 lagging (adjustable)Power Curtailment (kVA) 0...110%/0.1% Steps
INP
UT MPPt Range (VDC)[3] 330V-600V
Max. permissible DC voltage 600VMax. continuous DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000AMax. short circuit DC current (A) 650A 975A 1300A 1625A 1950A 2275A 2600A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY
Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%Weighted CEC Efficiency (η) 98.0% 98.0% 98.0% 98.0%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power SupplyBuilt-in Internal transformer as standard
(Optional external 3x208VAC power supply and UPS backup system)Avg. Power Consumption 920W 1380W 1840W 2300W 2760W 3220W 3680W
CA
BIN
ET
Dimensions [WxDxH] mm
mm[4] 1900x1020x2400 2900x1020x2400 3900x1020x2400 4900x1020x2400inches 74.8 x 40.2 x 94.5 114.2x 40.2 x 94.5 153.5 x 40.2 x 94.5 192.9 x 40.2 x 94.5
Weight[5] kg 1720 2780 3850 4900lbs 3800 6130 8500 10800
Air Flow Intake through lower part blown out through upper sideType of ventilation Forced
EN
VIR
ON
-M
EN
T
Degree of protection NEMA 3RPermissible Ambient Temperature[6] -4° F to +122° F /-20°C …+50°CRelative Humidity 4% to 100%Max. Altitude (above sea level)[6] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[7] < 70 dBA
CO
NTR
OL
INTE
RFA
CE Interface Alphanumeric display
Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)
Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100Digital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault ProtectionFloating PV array: Isolation Monitoring per MPP
Grounded PV array (Positive pole and negative pole): GFDI protection per MPPHeating Resistors StandardEmergency Stop OptionalGeneral AC Circuit Breaker Standard; External OperationAC contactor Standard in each moduleAC Circuit Breaker Standard in each moduleDC Contactor Standard in each moduleDC Fuses Standard in each module
General DC protection Optional Disconnecting Unit Cabinet
(DC fuse protection and on-load disconnector with external operating handle)Overvoltage Protection DC and AC Inverter sides ( Type 4) and Auxiliary Supply type 2- Internal StandardLightning Protections Optional (Integrated in the inverter)
FREESUN SOLAR INVERTER / POWER ELECTRONICS
[[1] Values at 50°C.[2] Maximum ambient temperature 40°C.[3] Values at 1.00·Vac nom and cos Ф = 1.[4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary. Consult Power Electronics.[6] Other characteristics consult with Power Electronics.[7] Sound pressure level at a distance of 1m from the rear part.
03.
FR
EE
SUN
HE
C-U
L
HEC-UL TechnicalCharacteristics 208VAC
208VAC - MPPt range 330Vdc-600VdcFRAME 0 - FS FRAME 1 - FS FRAME 2 - FS FRAME 3 - FS
NUMBER OF MODULES 2 3 4 5 6 7 8
FREESUN MODEL NUMBER FS0160CU FS0240CU FS0320CU FS0400CU FS0480CU FS0560CU FS0640CU
OU
TPU
T
Continuous AC Output Power (kVA)[1] 160 240 320 400 480 560 640Max. apparent Power (+10%) (kVA)[2] 176 264 352 440 528 616 704Continuous Output AC Current(A) 444 666 888 1110 1332 1554 1776Operating Grid Voltage(VAC) 208VacOperating Range, Grid Frequency 60HzVoltage Ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerPower Factor (cos phi)/@max. power 0.0 leading...0.0 lagging / 0.90 leading … 0.90 lagging (adjustable)Power Curtailment (kVA) 0...110%/0.1% Steps
INP
UT MPPt Range (VDC)[3] 330V-600V
Max. permissible DC voltage 600VMax. continuous DC current (A) 500A 750A 1000A 1250A 1500A 1750A 2000AMax. short circuit DC current (A) 650A 975A 1300A 1625A 1950A 2275A 2600A
EFF
ICIE
NC
Y &
A
UX
. SU
PP
LY
Max. Efficiency PAC, nom (η) 98.6% 98.6% 98.6% 98.6%Weighted CEC Efficiency (η) 98.0% 98.0% 98.0% 98.0%Max. Standby Consumption (Pnight) < approx. 40W/per module
Control Power SupplyBuilt-in Internal transformer as standard
(Optional external 3x208VAC power supply and UPS backup system)Avg. Power Consumption 920W 1380W 1840W 2300W 2760W 3220W 3680W
CA
BIN
ET
Dimensions [WxDxH] mm
mm[4] 1900x1020x2400 2900x1020x2400 3900x1020x2400 4900x1020x2400inches 74.8 x 40.2 x 94.5 114.2x 40.2 x 94.5 153.5 x 40.2 x 94.5 192.9 x 40.2 x 94.5
Weight[5] kg 1720 2780 3850 4900lbs 3800 6130 8500 10800
Air Flow Intake through lower part blown out through upper sideType of ventilation Forced
EN
VIR
ON
-M
EN
T
Degree of protection NEMA 3RPermissible Ambient Temperature[6] -4° F to +122° F /-20°C …+50°CRelative Humidity 4% to 100%Max. Altitude (above sea level)[6] 1000m; >1000m power derating 1% Sn (kVA) per 100mNoise level[7] < 70 dBA
CO
NTR
OL
INTE
RFA
CE Interface Alphanumeric display
Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP)
Analogue Inputs 1 programmable and differential inputs; (0-20mA or ± 10mV to ± 10V) and PT100Digital Outputs 2 electrically-isolated programmable switched relays (250VAC, 8A or 30 VDC, 8A)
PR
OTE
CTI
ON
S
Ground Fault ProtectionFloating PV array: Isolation Monitoring per MPP
Grounded PV array (Positive pole and negative pole): GFDI protection per MPPHeating Resistors StandardEmergency Stop OptionalGeneral AC Circuit Breaker Standard; External OperationAC contactor Standard in each moduleAC Circuit Breaker Standard in each moduleDC Contactor Standard in each moduleDC Fuses Standard in each module
General DC protection Optional Disconnecting Unit Cabinet
(DC fuse protection and on-load disconnector with external operating handle)Overvoltage Protection DC and AC Inverter sides ( Type 4) and Auxiliary Supply type 2- Internal StandardLightning Protections Optional (Integrated in the inverter)
64_65
[[1] Values at 50°C.[2] Maximum ambient temperature 40°C.[3] Values at 1.00·Vac nom and cos Ф = 1.[4] Units with integrated DU subsystem (HEC+) will increase 1000mm in width.
NOTES [5] Preliminary. Consult Power Electronics.[6] Other characteristics consult with Power Electronics.[7] Sound pressure level at a distance of 1m from the rear part.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HEC-UL Efficiency CurvesOperational Diagram
EFFICIENCY CURVES
OPERATIONAL DIAGRAM
CONFIGURABLE RATINGS
1 Module
2 Modules
6 Modules
8 Modules
e (%
)
P / Pnom (%)
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%84
86
88
90
92
94
96
98
E�ciency curves from 1 to 8 150 kVA modules, 590 Vdc.Consult Power Electronics for other configurations.
+
-
DC
BUSAC
CONTACTOR
T(ºC)
A
208-
390V
AC
BU
S
M1.1
(+)
UP
TO
8
MODULES
C
AN
CO
MM
UN
ICA
TIO
NS
YN
CH
RO
NIZ
ATI
ON
MODULE
1
DC
BUSAC
CONTACTOR
M1.2
(+)
M1.n
(+)
M1.1
(-)M1.2
(-)
M1.n
(-)
T(ºC)
A A
A
M8.1
(+)M8.2
(+)
M8.n
(+)
M8.1
(-)
M8.2
(-)
M8.n
(-)
ETH
ER
NE
TC
OM
MU
NIC
ATI
ON
ETHEWIFI
RNET
SWITCH
OVERVOLTAGE
PROTECT ON
MODULE
8
RS485
A
A
A
A
+
-
CONTROL
CONTROL
METEO - STATIONPOWER CONTROL INTERFACE
FREESUN DATA CENTER
FREESUN APP DISPLAY
FREESUN WEB DISPLAY
Communication Ports: RS485, RS232, USB
Analogue and Digital E/S
GROUND FAULT PROTECTION
MO
DU
LAR
MP
Pt D
C B
US
UP
TO 4
MP
Pt
DCCONTACTOR
INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
FUSES
STIN
U G
NITCE
NN
OCSID
)LA
NOITP
O(
CIRCUIT BREAKER
R
S
T
208V
AC
PO
WER
SOU
RC
E 2k
VA
PE
OVERVOLTAGEPROTECTION
L1
L2
L3 208
– 39
0VA
CO
UTP
UT
POW
ER
OVERVOLTAGEPROTECTION
AUXILIARTRANSFORMER
EM
C F
ILTE
R
Aux
iliar
y Po
wer
SU
pply
400
VAC
FUSES ON-LOADDISCONNECTOR
FUSES ON-LOADDISCONNECTOR
DCCONTACTOR
FUSES INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
EM
RET
LIF
C
R
S
TPE
208V
AC
EX
TER
NA
LPO
WER
SU
PPLY
EM
CFI
LTE
RE
MC
FILT
ER
208-330-360-390 / 208
(OPT
ION
AL)
CIRCUIT BREAKER
MAIN AUXILIAR
EM
CFI
LTE
R
MPPt RANGE (VDC) [2]
# MODULES 330V-600V 500V-820V 540V-820V 585V-820V
2 160kVA 250kVA 280kVA 300kVA
Nominal AC Output Power
(kVA)[1]
3 240kVA 380kVA 420kVA 450kVA4 320kVA 500kVA 560kVA 600kVA5 400kVA 630kVA 700kVA 750kVA6 480kVA 750kVA 830kVA 900kVA7 560kVA 880kVA 970kVA 1050kVA8 640kVA 1000kVA 1110kVA 1200kVA
AC Output Voltage 208Vac 330Vac 360Vac 390Vac
[1] Values at 50°C, 60Hz [2] Values at 1.00·Vac nom and cos Φ= 1.
66_67
03.
FR
EE
SUN
HE
C-U
L
HEC-UL Dimensions
HEC HEC+
FRAME 0 1900x1020x2400 2900x1020x2400
FRAME 1 2900x1020x2400 3900x1020x2400
FRAME 2 3900x1020x2400 4900x1020x2400
FRAME 3 4900x1020x2400 5900x1020x2400
FRAME 0 FRAME 1
FRAME 2
FRAME 34900
240
0
240
0
3900
240
0
2900
240
0
1900
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HEKSolar Inverter
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Freesun HEK open skid platform offers the maximum
yield and reliability, being ready to connect up to 2.5MW
FREESUN HEK Open Skid Platforms are fully outdoor solutions tailored for large utility scale PV plants, complete with factory integrated DC disconnection and protection, Freesun HEC solar inverters, step-up pad-mount transformer and auxiliary equipment. The MW Skid blocks will reduce the project complexity and costs by improving the road transportation, installation, commissioning and maintenance.
Freesun HEC-UL inverters are equipped with the latest industrial developments which offer the maximum yield and proven reliability for your utility scale projects.
03.
FR
EE
SUN
HE
K
68_69
FREESUN SOLAR INVERTER / POWER ELECTRONICS
HEK TechnicalCharacteristics
[1] Consult Power Electronics for derating curves.[2] Available adjustable power factor 0.80leading…0.80 lagging, consult P-Q charts.[3] Values at 1.00Vac nom and cos Φ= 1.[4] Maximum DC cable section per connexion and pole. The installer must also consider for the cable selection the factors such as length of cable for each
NOTES installation, environmental conditions, aluminium conductors, installation methods and requirements set out in current regulations applicable in the country of installation.[5] Other characteristics consult with Power Electronics.[6] Preliminary dimensions and weight.
SAMPLE INVERTER CONFIGURATION HEK - 1.2MWFS1200PU
HEK - 1.5MW 2x(FS0751PU)HEK - 1.66MW 2x(FS0830PU)
HEK - 2MW 2x(FS1000PU)HEK - 2.4MW2x(FS1200PU)
HEK - 2.5MW2x(FS1250PU)
AC
OU
TPU
T
MV Output Voltage(V) 13.8kV(± 10%)Nominal Power (kVA) @ 50°C[1] 1200kVA 1500kVA 1660kVA 2000kVA 2400kVA 2500kVAInverter Output Voltage (V) 390Vac 390Vac 360Vac 330Vac 390Vac 390VacRated Frequency and Variation 60Hz (± 0.2%)Inverter Max. Output Current (A) 1776 2x1110 2x1333 2x1750 2x1776 2x1850Current Harmonic Distortion (THDi) <3% THDiPower Factor(cos phi)[2]/@max. power 0.0 leading...0.0 lagging / 0.90 leading…0.90 lagging (adjustable)Power curtailment (%) 0..100% /0.1% Steps
TRA
NSF
OR
ME
R &
MV
SW
ITC
HG
EA
R
Transformer Type Pad Mount - Loop or radial feed dead frontInput/Output Voltage 0.390kV/13.8kV 2x0.390kV/13.8kV 2x0.360kV/13.8kV 2x0.330kV/13.8kV 2x0.390kV/13.8kV 2x0.390kV/13.8kV
Transformer Vector configuration Dyn11 Dyn11 -Double or Single Winding (TWIN Inverters)
MV Switchgear
200A HV bushingFR3 Dielectric fluid Winding temp. rise 65°C
2FCAN, 2FCBN @2.5%Liquid temperature gauge, Pressure vacuum gauge, Liquid Level gauge, Pressure relief valve
200A two position load break switchBayonet fuse in series with the current limiting fuse
INP
UT
W/D
U
DC Voltage Range MPPT (VDC)[3] 520Vdc-820Vdc 520Vdc-820Vdc 540Vdc - 820Vdc 500Vdc-820Vdc 520Vdc-820Vdc 520Vdc-820Vdc
Max. permissible DC voltage 1000VdcMax. continuous DC current (A) 2000A 2500A 3000A 4000A 4000A 4000AMax. shortcircuit current 2600A 2x1625A 2x1950A 2x2600A 2x2600A 2x2600AArray Configuration Floating earth or grounded pole
AU
XIL
IAR
YSE
RV
ICE Inverter Power Supply Built-in transformer 3P -330/360/390/400Vac - 208Vac Optional built-in UPS System
Station Auxiliary transformer Optional 15kVA,30kVA -208V,120V
Optional Equipment [5] Communication CabinetLow Voltage Cabinet
ME
CH
AN
ICA
L
DA
TA
Dimensions (feet) (WxL) [6] 7´x 30´ 9´- 73/4" x 34´
Weight (lb) [6] 30.000 45000 - 51500
Enclosure Stainless Steel construction & Rockwool Panel Sandwich isolation
Cooling Independent VSD control cooling - Intake through the bottom part blown out through the top
Skid construction 10" Channel base frame, skid base frame height 1"
EN
VIR
ON
ME
NT Degree of protection Outdoor (NEMA3R)
Permissible Ambient Temperature[5] -20°C …+50°C
Humidity 0% to 95% Condensing – Active heating controlled by higrometer
Max. Altitude (above sea level)[5] 1000m; >1000m power derating 1% Sn (kVA) per 100m
Noise level < 70 dBA
CO
NTR
OL
INTE
RFA
CE Communication RS232 / RS485 / USB / Ethernet, (Modbus RTU Protocol, Modbus TCP/IP, Optional GSM / GPRS)
Inputs & Outputs 1AI, 2DO, programmable per module
Interface Graphic Display / Optional Freesun Web display or App display
Monitoring Freesun Data Center, Freesun Web Portal, Open Modbus RTU protocol
GR
ID
SUP
PO
RT
&
STA
ND
AR
DS Grid Support Functions LVRT, HVRT, ZVRT, FRT, Ramp rate, Reconnection, Anti-Islanding,
Power curtailment, PF control, Remote Stop, Compatible with every local requirement
Protections E-Stop, 2xHV, 2x LV, 2xHF, 2xLF, current & voltage unbalance, OC protections, others consult PE
Standards Freesun Inverter UL1741, CSA 22.2 No.1071-01, IEEE1547,
Standards Power TransformerIEEE - C57.12.00, IEEE C57.12.34, IEEE C57.12.28, IEEE, C57.12.29,
IEEE C57.12.70, IEEE, C57.12.80, IEEE C57.12.90, IEEE C57.9 and NEMA
HEK PLATFORM - 2.4MW[1]
~
FREESUN HEC -UL
3~
=
3
=
3~
=
3~
=
ACCirc. Breaker & Contactor
DCContactor
& Fuses
AC Gen.Circ. Breaker
DCDisconnector
& Fuses
FREESUN HEC -UL
3~
=
3
=
3~
=
3~
=
ACCirc. Breaker & Contactor
DCContactor
& Fuses
AC Gen.Circ. Breaker
DCDisconnector
& Fuses MV Disconnector
MV Fuses
PAD MOUNT TRANSFORMER
Pad-mount transformer
Station auxiliary transformer
AC disconnection and control cabinet
Platform
Freesun HEC-UL
DC disconnectionand protection
70_71
OPERATIONAL DIAGRAM
SKID TOPOLOGY
03.
FR
EE
SUN
HE
K
Other configurations consult Power Electronics. Some Freesun HEK units may differ from the concept shown in the image.
NOTES
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
ENERGY STORAGESolar solutions
04.
EN
ER
GY
STO
RA
GE
72_73
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
BESSBattery Energy Storage System
74_7574_75
The decentralized and uncontrollable photovoltaic energy generation presents grid stability challenges and loss of profitability. Power Electronics’ Battery Energy Storage System (BESS) is a turnkey and tailored solution designed for utility-scale PV plants that demand the stringent grid interconnection requirements. From on-grid applications that requires the fast dynamic support functions to those off-grid applications that look for load levelling strategies.
Freesun well-proven equipment can be connected with any available battery technology such as lithium-polymer, lithium-ion, Ni-Cd, Fe-Cl or Vn redox-flow,… However Power Electronics relies on lithium-polymer batteries powered by Kokam. A reliable and flexible manufacturer, committed to client and ready to face the challenges that the PV facilities are addressing worldwide.
04.
FR
EE
SUN
BE
SS
Power Electronics’ BESS offer reliability and flexibility to
cutting-edge tech projects
BESS SERIES
FREESUN SOLAR INVERTER / POWER ELECTRONICS
The BESS comprises a lithium-polymer battery container connected to a Freesun PCS (Power Conversion System) that follows the instruction of the main governor of the plant the Freesun PPC (Power Plant Controller).
Freesun PPC is a PLC based microprocessor that monitors the POI (Point of Interconnection) and determines the active and reactive power set points of the inverter units. It can perform multiple power and dynamic grid support functions such as:
PEAK SHAVINGReduce your fixed cost by reducing your maximum power demand.
POWER RAMP UP/DOWN CONTROLSmooth the rate of change of power due to a cloud cover or other sources.
LOAD LEVELLINGReduce the maximum amount of energy purchased from utility during peak hours.
Battery Energy Storage System
POWER PLANT CONTROLLER
(PPC)
PUBLICGRID
Point of interconnection
(POI)
ENERGY STORAGE SYSTEM
MV
SU
BS
TA
TIO
N B
US
DC
PV PLANT FREESUN INVERTER
GRID CONTROLLER
FREESUN PCSPOWER CONVERSION SYSTEM
PC
S
2000
1800
1600
1400
1200
1000
800
600
400
200
0
-200
-400
-600
-800
kW
Solar Production (kW)Active Power at POI (kW)
PCS - Battery Discharge (kWh)PCS- Battery Charge (kWh)
TIME
OU
TP
UT
TIMECompany Load
Discharging
ChargingCharging
Maximum powercontracted by the cutomer P
OW
ER
TIME
STORAGE BATTERY SYSTEM
Solar power outpoutStorage battery system
Peak hours
Discharging
Charging Charging
76_77
The KCE Battery Container is suited for medium and large scale application from 100kWh to 2MWh. It can be delivered in a 20 feet or 40 feet steel container that houses the battery banks, the BMS system, cooling system and the entire safety equipment ready to connect the DC wiring. Each battery bank can be equipped from 1 to 5 parallel connected battery racks, and at the same time the battery bank is connected to a Freesun PCS that transform the direct current to alternate current. Each battery rack comprises a connection of lithium-polymer battery modules in series that leads to an operating voltage range from 600Vdc to 800Vdc.
Each battery rack is monitored by its own Data BMS that informs the system BMS and Freesun PCS about SoC (State of Charge), cells temperature, current and voltage protections, charge and discharge current and voltage limits.
Battery cell Battery module Battery rack
A MODULAR ESS AND PCS ALLOW POWER ELECTRONICS
TO ADDRESS EACH SINGLE CHALLENGE WITH THE MOST COST-EFFECTIVE PROPOSAL
FREqUENCY REGULATION SYSTEMActive power control to support the stabilization of the grid frequency. The BESS discharges and charges the battery in overfrequency and underfrequency issues respectively.
VOLTAGE REGULATION SYSTEMReactive power control to stabilize the grid voltage. Cos φ regulation from pure lagging to pure leading.
04.
FR
EE
SUN
BE
SS
f(H
z)
50.02
50.04
50.00
49.98
TIME
Charging Discharging Grid load
1.06
1.08
1.04
1.02
0.98
0.96
0.94
0.92
Voltage at POI
TIME
VOLTAGE
Voltage at POI with VRS activated
FREESUN SOLAR INVERTER / POWER ELECTRONICS
PCSPower Conversion System
FREESUN SOLAR INVERTER / POWER ELECTRONICS
PCSPOWER CONVERSION SYSTEM
Power Conversion System
Proven hardware and rugged outdoor design featured with
the latest control
For decades, the energy production industry is being deregulated and new markets are embracing the renewable energy sources. Their high penetration is creating power transmission instability challenges, thus Grid Operators request stringent dynamic and static grid support features to solar inverters and Power Conversion Systems (PCS).
Freesun PCS offers proven hardware to cope with this new storage and grid support challenges. It includes high advance control software with the latest Voltage and Frequency Ride Through features, and together with the Freesun solar inverters, a Power Plant Controller and a battery set will supply the active power required to perform the desired Ramp Rate and frequency regulation Control.
Backed by our proven solar inverter series, Power Electronics offer indoor or outdoor units, or a complete PCS stations. The PCS stations are turnkey solutions that are ready to connect the battery container and the MV power distribution wiring. It is available over a concrete station, steel container or open skid platform that include the PCS unit, the MV power transformer, the MV protection cells and the LV auxiliary cabinets.
Freesun PCS is a modular IEC and UL compliant solution from 300kW to 1800kW with configurable DC and AC voltages that make it compatible with all the battery technologies and manufacturers. Power Electronics is the best partner for your MW installation by means of its reliability engineering and outstanding guarantee condition.
04.
FR
EE
SUN
PC
S
78_79
FREESUN SOLAR INVERTER / POWER ELECTRONICS
FREESUN PCS
OUTPUT
Nominal AC Output Power (kVA) [1] 125kVA – 1800kVAOverload (%) 125% < 60s
Output Voltage (VC) PCS unit 360Vac - 440VacPCS stations 10kV - 36kV
Grid frequency 50Hz – 60Hz Voltage ripple, PV Voltage < 3%Current Harmonic Distortion (THDi) < 3% at nominal powerReactive power compensation 0.0 leading… 0.0 lagging adjustable
INPUT
DC voltage range (Vdc) 540V-850VMaximum DC voltage (Vdc) 1000VMaximum DC current (A) 500A - 3000ABattery technology All compatible (BMS required)
EFFICIENCYEfficiency PAC (η) > 97% at rated power
Standby consumption (Pnight) < aprox. 400W
ENVIRONMENTAL CONDITIONS
Degree of protection Indoor Units -IP21
Outdoor Units - IP54Maximum ambient temperature [2] -20°C …+50°C
Relative Humidity (%) Indoor units: 10% to 95% non condensingOutdoor units: 4% to 100% condensing
Max. Altitude (above sea level) [2] 1000m; 1000m 1% power derating Sn (kVA) per 100mNoise level [3] < 79dBACooling Forced VSD cooling
CONTROLCommunications
RS232 / RS485 / USB / Ethernet, (Protocol Modbus RTU, Ethernet TCP/IP, Optional GSM / GPRS)
User interconnection 1AI, 2DO, programmable per module (Max. 8-10)Plant Manager Freesun Power Plant Controller (PPC)
DYNAMIC GRID SUPPORT
Reactive Power Compensation
Local or remote by PPC setting (cos ɸ or %)Automatic curve Q(Active Power)
Automatic step curve Q(AC voltage) Automatic hysteresis curve Q(AC voltage)
Voltage Ride Trough capability Dual setting high and low voltage protection - 0-470Vac, 0.01s -60sFrequency Ride Trough capability Dual setting high and low frequency protection, -5% to +4%, 0.01s -100sGrid Support Voltage DIPs Standard built-inAnti-islanding Standard built-inPCS reconnection Configurable: 5..120s delay time, 1 to 30 attempts, Attempts auto-resetReconnection ramp rate Adjustable
PROTECTIONSAC disconnection AC circuit breaker
DC Overcurrent protection Optional General DC fuse cabinet and DC on-load disconnectorsGround fault Ground fault monitoring
[1] Values at 40°C[2] Other characteristics, consult Power Electronics.[3] Sound level at a distance of 1m from the rear and front part.
PCS TechnicalCharacteristics
NOTES
80_81
OPERATIONAL DIAGRAM
+
-
DC
BUSAC
CONTACTOR
T(ºC)
A
360-
440V
AC
BU
S
M1.1
(+)
UP
TO
10
MODULES
CA
NC
OM
MU
NIC
ATI
ON
SY
NC
HR
ON
IZA
TIO
N
DC
BUSAC
CONTACTOR
M1.2
(+)
M1.n
(+)
M1.1
(-)M1.2
(-)
M1.n
(-)
T(ºC)
A A
A
M10M10
M10
M10
M10
M10
.1
(+).2
(+)
.n
(+)
.1
(-)
.2
(-)
.n
(-)
ETH
ER
NE
TC
OM
MU
NIC
ATI
ON
ETHERNET
SWITCH
OVERVOLTAGE
PROTECT ON[2]
RS485
RS485
A
A
A
A
+
-
CONTROL
CONTROL
STRING SUPERVISOR
METEO - STATIONPOWER PLANT CONTROLLER
Communication Ports: RS485, RS232, USB
Analogue and Digital E/S
GROUND FAULT PROTECTION
MO
DU
LAR
MP
Pt D
C B
US
UP
TO 4
MP
Pt
DC CONTACTORAND FUSES
DC CONTACTORAND FUSES
INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
STIN
U G
NITCE
NN
OCSID
)LA
NOITP
O(
CIRCUIT BREAKER
R
S
T
400V
AC
PO
WER
SOU
RO
ptio
nal
CE
5kVA
PE
OVERVOLTAGEPROTECTION[2]
L1
L2
L3 360
– 44
0VA
CO
UTP
UT
POW
ER
OVERVOLTAGEPROTECTION
AUXILIARTRANSFORMER
FUSEPROTECTION
EM
C F
ILTE
R
Aux
iliar
y Po
wer
SU
pply
400
VAC
FUSES ON-LOADDISCONNECTOR
FUSES ON-LOADDISCONNECTOR
INVERTERBRIDGE
SINUSOIDALFILTER
AUTOMATICCIRCUIT
BREAKER
EM
RET
LIF
C
R
S
TPE
400V
AC
EX
TER
NA
LPO
WER
SU
PPLY
EM
CFI
LTE
RE
MC
FILT
ER
360-440Vac
(OPT
ION
AL)
MODULE 10
WIFI
FREESUN DATA CENTER
FREESUN APP DISPLAY
FREESUN WEB DISPLAY
MODULE 1
04.
FR
EE
SUN
PC
S
FREESUN SOLAR INVERTER / POWER ELECTRONICS
PPCPower Plant Controller
FREESUN SOLAR INVERTER / POWER ELECTRONICS
02.
CO
NT
EN
IDO
It’s a reality, we have already reached photovoltaic – diesel parity!
For decades, high power facilities have been located in isolated areas that have made investment in grid connection unfeasible, so many have been powered by gas, diesel or fuel generators. Despite a rising trend in oil prices and government taxes imposed on high CO2 producers, any other feasible technologies have not been available until now.
The integration of an alternative power source creates an unprecedented opportunity to reduce operational costs to off-grid industrial and commercial facilities. Freesun’s design and topology bring together the engineering expertise in industrial power electronics development, and the solar plants economic and technical capability. We are aware of continuous operation applications and we understand that a process shutdown could result in a large reduction of income for your company. Therefore a unique modular and redundant system, ensures the availability of string inverters and the competiveness of central inverters. We offer a set of solutions that can be customised to your facilities to ensure maximum yield and optimal energy management.
Power Electronics is already supplying in world leading companies in Mining, Water and the Oil & Gas sector around the globe (Australia, Brazil, Chile, Germany, Mexico, Mongolia, New Zealand, Korea, South Africa, Spain…) due to a highly reliable product and from what has brought us to where we are now; outstanding technical service POWER ON SUPPORT, together with our vertically integrated production which allows us to offer unique delivery times.
82_83
04.
FR
EE
SUN
PP
C
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Facilities with a high load profile that are considering a progressive PV penetration in their off-grid power supply are able to install the Freesun HE solar inverters without any additional control, measurement or communication hardware. The GenSet acts as the main governor of the system running under normal operation mode by balancing the power through the variation of the grid frequency (ISO8528-5:2005). The HEC Inverter, coupled by the AC bus, monitors the frequency and adjusts its power injection in order to both maximize the fuel saving, and to ensure minimum GenSet load and spinning reserve. Additionally, dynamic grid support features can be programmed to enhance your plant power quality.
• Compatible with new and retrofit projects• Scalable system• No additional hardware• PV penetration depends on the load profile
GENERAL DATA
Dimensions (WxDxH) 265 x 146 x 66 mm
Weight 635g
Enclosure 2mm Steel
Mounting system DIN35 rail, wall mounting anchorages
Compatible Inverters Freesun HE and PCS by Power Electronics
POWER SUPPLYVoltage, Consumption, Freq. 100Vac -240 VAC , 100mA, 50Hz-60Hz
Socket C type
DIGITAL INPUTS 4 x Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated
COMMUNICATIONS [1]
1 x RS485 Port 3 wires (GND,A,B), Modbus RTU
1 x USB Port PC connectable using a master Modbus configurator (ModScan or similar). Reserved for TS.
1 x CAN Port 3 wires (LO,GND, HI), Modbus RTU
1 x Ethernet Port (RJ45) Modbus TCP/IP
ENVIRONMENTAL CONDITIONS
Operation Temperature 0 - 50°C (32°~128°F)Altitude < 2000m above sea level
Storage temperature -20 - 80°C (-4°~176°F)
Humidity 5 - 95% (non-condensing)
Degree of protection IP20
CERTIFICATES CE
OTHERSWeb interface for local and remote monitoring
Customised solution
PPC TechnicalCharacteristics
PLUG AND PLAY
[1] Communication parts can be customized depending on PV plant design without prior notice.
PV PANELS
FREESUNSOLAR INVERTER
GEN SET 1
MINE
LOAD
PV contribution Extra PV Power available GenSet contribution Load Profile
500kW
250kW
0kW00:00 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 24:0022:00
Main GenSet load
ILUSTRATIVE
PV INVERTER LOAD (%)GEN SET LOAD (%)
frequency (Hz)50Hz
0 %
50%
100%
0 %
50%
100%
52Hz
Min GenSet Load
GenSet Power vs Frequency responseHE Inverter Power vs Frequency response
84_85
06.
The Freesun Power Plant Controller (PPC) will be the main governor of the most complex hybrid systems by monitoring the point of interconnection (POI) and at the same time controlling the power generation and storage equipment.The PPC is equipped with the latest PLC based microprocessor that interacts through the programmable digital/analogue signals and communication ports (Modbus RTU –RS485/fiber optics or Modbus TCP/IP- Ethernet TCP/IP). The Freesun PPC together with the Freesun HE family inverter series can be customised for those countries (Puerto Rico, Hawaii….) that require full compliance to stringent dynamic grid support response at POI.
• PPC main governor and interface of the system• Multiple GenSets control• No storage- PV penetration depends on load profile• Centralized dynamic grid support at POI
• PPC main governor and interface of the system• Multiple GenSets and storage equipment control• Centralised dynamic grid support at POI• Power shaping - Enhanced broad implementation of decentralised PV• Power smoothing – Enable ramp rate control
POWER PLANT CONTROLLER
04.
FR
EE
SUN
PP
C
PV PANELS
FREESUNSOLAR INVERTER
kW
GEN SET 1
GEN SET 2
FREESUN PPC
MINE
INTERFACE
LOAD
2000kW
1500kW
1000kW
500kW
00:00 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 24:0022:00
PV contribution GenSet 1 Load ProfileGenSet 2 GenSet 3
ILUSTRATIVE
PV PANELS
FREESUNSOLAR INVERTER
kW
GEN SET 1
GEN SET 2
FREESUN PPC
MINE
INTERFACE
STATCOMBATTERIES
LOAD
2000kW
1500kW
1000kW
500kW
00:00 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 24:0022:00
PV contribution GenSet 1 Load ProfileGenSet 2Energy Storage Energy injection
GenSet 3
ILUSTRATIVE
FREESUN SOLAR INVERTER / POWER ELECTRONICS
COMMERCIAL SCALESolar Inverters
|
||||||
||||
www.tuv.com |||||||||||
ID:2000000000TÜVRheinland
BAUARTGEPRÜFT
TYPE APPROVED
05.
FR
EE
SUN
LV
T
86_87
FREESUN SOLAR INVERTER / POWER ELECTRONICS
LVTSolar Inverter
88_89
05.
Freesun LVT is the perfect definition of solar
technology, reliable and comprenhensive
Freesun LVT series is the perfect solution for commercial scale solar PV plants, being available from 20 to 100kW.
Equipped with a high efficiency low voltage transformer, it is the most robust and compact central inverter both indoor and outdoor versions, featuring the last dynamic grid support features, FFA (Full Frontal Access), stand alone cabin, DC/AC protections, and PMTA (Power Multiple Tracking Algorithm).
Easy to install and ready to produce with the highest quality performance certified by TÜV Rheinland.
FR
EE
SUN
LV
T
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Based on our experience in the industrial sector, we know how important it is to have full access to the vital elements of the equipment. This not only means that you can see the “inside” of your inverter easily, it also helps any servicing and maintenance to be made with no effort. In Power Electronics we believe that doing things better is always an advantage for the client, and this is why we work to make give full access to all the important elements of the inverter.
Full Frontal Access FFA
FULL FRONTAL ACCESSEvery electrical component accessible
DC Circuit Breakers
Power Board
Control Board
AC Circuit Breaker
AC Output TerminalsDC Input Terminals
It has a yield of 96.5% and 97.1% European maximum efficiency. However, we know that what gives an inverter a true efficiency throughout the years is not only the rates, but a number of other important aspects to be considered.
Conditions. The LVT inverter is able to operate in adverse weather conditions being tested to work without derating or production loss in temperatures ranging from -20°C to +50°C. Thus the series LVT can be considered one of the strongest inverters in the market .
Testing. Also, after thorough testing in our laboratories with a climatic and anechoic chamber, the inverter LVT has passed all European certifications regarding electromagnetic emissions, which make it a compatible system with the strictest requirements of our customers.
Certification. The quality and safety design have been certified by TÜV Rheinland.
Protections. The use of all necessary protections: overvoltage protector, isolating monitoring, DC EMC filter and EMC output filter, and the overvoltage protector among others, provide the LVT with all possible control elements to guarantee the safety of the inverter, the installation and the grid.
Conformal Coating. All the electronics are treated with a selective varnish, which we use as standard for all our equipment, specially designed to resist in environments with high presence of aggressive agents in the toughest conditions all over the world.
PMTA. The most advanced control of Maximum Power Point with our PMTA algorithm.
True 24h service. Not to forget Power Electronics’ commitment to 24h service every day of the year, which means that you will have the fastest and best service in the market, with a permanent true Power On Support phone line available with direct contact with technical engineers. This is what we call... Efficiency.
Efficiency
90_91
05.
FR
EE
SUN
LV
T
Available both for indoor and outdoor versions the most advanced cooling system keeps the electronic components within the operating temperature range even in the most difficult situations without ongoing maintenance. We have great experience in high temperature environments (around 50°) with no power derating.
Ventilation
Freesun LVT series inverters are easy to install, all parameters are factory pre set to allow a quick installation. Once you make connections, the inverter is able to synchronize automatically.
Anyone can start up the LVT without having specific training.
Commissioning (Start Up)
Simple reliable and safe, the LVT has all the necessary protections based on the latest legislation such as the Italian CEI 0-21, G 59/2 English and German VDE.
Any anomaly coming from the PV installation will not affect the solar inverter or the grid due to both the DC and AC protections built in the inverter.
Protections
92_93
05.
FR
EE
SUN
LV
T
FREESUN SOLAR INVERTER / POWER ELECTRONICS
94_95
05.
FR
EE
SUN
LV
T
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
MonitoringSolutions
02.
CO
NT
EN
IDO
96_9796_97
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
FreesunPortal
06.
MO
NIT
OR
ING
SO
LUT
ION
S
98_99
• Freesun PortalGo online! Freesun Portal is an attractive and comprehensive monitoring tool available with one click through a free web service. The data sent by the Datalogger is stored in Power Electronics Database and meaningful plotted or exported. Whether an EPC or end user can easily check in real time, in any place in the world, and in any device, all the data retrieved by the inverter.
The system refresh every minute the data showing an accurate and comprehensive status of your PV facilities. A single password can give you access to multiple PV plants and at the same time a PV plant can be monitored by many users with different security levels. The web application allows you to introduce the plant information, to select multiple charts or plot intervals, to create daily, monthly or annual reports, and to export data to xls files
Website access www.freesunportal.com
Available InformationInverter and module status, Inverter and module Power (kW), Daily Energy (kWh), Total Energy (MWh), Inverter current (A), String current (A), Inverter and Module faults, Others available.
Features
Comprehensive and flexible chartsAnnual, Monthly, daily reports.Generation of historic data tables Historic data exportation XLS. FilesMultiple user licences and administrator capabilities
Language English, Spanish
System Requirements Internet Explorer 8, Firefox 5, Google Chrome 14, Safari 5, Opera 11Java Script and Cookies activated
Communication Modbus TCP/IPEthernet Ports Ethernet Switch ( 2x10/100 BaseT RJ45ports)Data 4Gb SD Card Features Real Time Clock, Watch Dog TimerInstallation Indoor,Operating/ Storage Temperature 0 to 50°C (32° to 122°F) / -20 to 70°C (-4° to 158°F)Operating /Storage Humidity 20 to 95% (non-condensing) / 0 to 95% (non-condensing)Certifications CE
Consult availability.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
FreesunDataCenter
FREESUN SOLAR INVERTER / POWER ELECTRONICS
02.
CO
NT
EN
IDO
100_101
• Freesun Data CenterThe Freesun Data Center is a data logger suitable for solar farms’ remote monitoring and control. Thanks to the dedicated Microsoft Windows Desktop application, you will easily receive e-mail alerts, or check from your home, office or laptop the daily energy production, weather conditions, security system, inverter status…
The system captures data every 15min showing an accurate and comprehensive status of the solar plant. The application allows you to customize the graphs characteristics and plot intervals (quarterly, hourly, daily, yearly). The trend graphs applet and the Excel export function gives you the opportunity to share the data or to compare the long term performance with other PV plants.
Freesun Data Center is compatible with multiple weather and control accessories such as: irradiance sensors, pyranometers, weather stations, security cameras or optical probes for energy meters.
For those interested in holding its own database, the Freesun Data Center is able to send simultaneously data frames to one or more remote servers. If the communication is lost, the FDC will locally save the data until the communication is restored.
06.
MO
NIT
OR
ING
SO
LUT
ION
S
Available Information
Inverter status, Inverter Power (kW), Daily Energy (kWh), Total Energy (MWh), Inverter current (A), String current (A), DC and AC voltages (V). Energy Meters Power (kW), Energy Meters data (MWh), Total Revenues (local currency), CO2 savings (kgCO2), Performance Ratio Calculation, Others available.
Features
Comprehensive and flexible chartsGeneration of historic data tables Historic data exportation XLS. FilesMultiple user licences and administrator capabilities
Programmable notifications SMS Messages (Requires GSM modem) - Email NotificationsLanguage English, Spanish, German, Italian
System Requirements
Windows XP/Vista/7; Internet Connection; Router Settings AccessIntel Celeron, Intel Pentium, Intel Core processor 32 et 64 bitsA minimum of 2GB RAM is recommended. 60MB free hard disk placeMinimum Microsoft .Net Framework 4.0
Datalogger Freesun Data Center (Webdom Labs)Communication Modbus
Serial Ports2xRS232, 2xRS232/422/485 w/DB9, Automatic RS485 data flow con-trolRS232: 300 to 115.2kbps ; RS422/485: 300 to 115.2kbps
Ethernet Ports 2x10/100 BaseT RJ45ports
External Signals Analog Output 4..20mA; 0..10V, (PT100/PT1000 compatible)Digital Input (+10Vdc to +30Vdc)
Power Supply Internal Inverter Supply (12Vdc – 30Vdc) 10W Data Onboard 32MB Flash memory - 4Gb Compact Flash MemoryFeatures Real Time Clock, Watch Dog Timer
Weather Stations and sensors Davis Vantage Pro 2, Mencke, Irradiance Sensor, Delta Ohm LP PYRA -02, -03, -10
Other accessories Optical Probe IEC1107 - Camera ACM-3100 Domo IP SuperCMOSOutdoor Camera SONY Super HAD ¼”
Installation Indoor,DIN RailOperating/ Storage Temperature 0 to 70°C (32° to 158°F) / -20 to 95°C (-4° to 176°F)Operating /Storage Humidity 20 to 95% (non-condensing) / 0 to 95% (non-condensing)Certifications CE, FCC and class AMonitoring Protocols IEC870-5-102; DLMS/COSEM, Backfilling System av
FreesunWeb/App display
FREESUN SOLAR INVERTER / POWER ELECTRONICS
102_103
• Freesun Web/App displayGo Wireless! The ultimate Freesun Web Display and Freesun APP display applications will play a key role on your Plant Service and Management. Any Windows, Android or IOS device will be easily wirelessly connected to the inverter creating a comprehensive and user friendly interface. Forget about using built-in displays with tiny screens or tedious menus, and allow your field technicians to service outdoor units under rain, snow or heavy sunny conditions, without opening or standing in front of the unit.
Freesun Web Display is an embebed application that allows the user to go deep into the unit by using a laptop. Freesun APP Display is a comprehensive APP compatible with IOS and Android devices. Both tools allow the user to monitor the inverter status and to modify the settings.
App display
Web display
Available Information
Inverter status, Inverter Power (kW), Daily Energy (kWh), Total Energy(MWh), Inverter current (A), String current (A), DC and AC voltages(V). Energy Meters Power (kW), Weather Station status, Energy Meters data (MWh), Others available.
Settings control Yes
Features
Easy Wireless connectionComprehensive interfaceReal time dataSave and copy settings
Language English, SpanishSystem Requirements IOS or ANDROID devicesDatalogger NoCommunication Modbus TCP/IP (Wireless)
Available Information
Inverter status, Inverter Power (kW), Daily Energy (kWh), Total Energy(MWh), Inverter current (A), String current (A), DC and AC voltages(V). Energy Meters Power (kW), Weather Station status, Energy Meters data (MWh), Others available.
Settings control Yes
Features
Easy Wireless connectionComprehensive interfaceReal time dataSave and copy settings
Language English, Spanish
System Requirements Internet Explorer 8, Firefox 5, Google Chrome 14, Safari 5, Opera 11Java and Cookies activated
Datalogger NoCommunication Modbus TCP/IP (Wireless)
06.
MO
NIT
OR
ING
SO
LUT
ION
S
Consult availability.
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
Accessories& CustomisedSolutions
Customers’ needs are continuously changing. That’s why Power Electronics provide full flexibility to large installation customers by adapting standard units to each project requirements. We are committed to create a smooth workflow and to offer the most suited solution to each single project worldwide. A team of qualified PV Engineers will support you during the whole plant life being the best partners for your investment.
Pre-sales
Design
Installation
Maintenance
Operation
Commissioning
104_105
• DC Outdoor stand-alone cabinetsOutdoor disconnection and protection unit that can fit 6 on-load disconnectors, which can be externally activated, 24 independent channels monitoring and a flexible set of fuses. It is suited to Freesun HEC outdoor inverters under harsh weather conditions.
• AC Built in-AC fuses or Circuit breaker Freesun HE inverters can fit AC fuses or Circuit breaker that protects Freesun inverters from AC shortcircuit.
• Indoor stand-alone AC cabinetsAn indoor LV or MV AC cabinet can fit any external relays, breaker and protections required by the utility. Consult Power Electronics.
FREESUN SOLAR INVERTER / POWER ELECTRONICS
• DC built-inA combination of DC fuses and on-load disconnectors can be fitted in one or two module’s frame. This solution leads to a limitation of the maximum inverter modules that can be fitted in the same inverter frame size.
DISCONNECTION AND PROTECTION
• Outdoor wall-mounted cabinetsIt’s a fully customizable wall-mounted outdoor cabinet suited for Freesun HES Stations. Ordering the complete PV station it will be delivered all wired to the inverter and assembled to the station.
Considering that large photovoltaic systems are normally connecting in parallel a great number of strings, it can be difficult to detected malfunctions in individual modules. With the STRING SUPERVISOR system developed by Power Electronics, we enhance plant efficiency and module protection by monitoring and protecting from 8 to 24 independent channels. Every string supervisor box is featured with:
• Max. 1000Vdc and compatible with any module.• Positive and negative poles can be fuse protected.• Built-in overvoltage protection• IP65 Robust outdoor enclosure with low maintenance and minimal wear.• Low stand-by consumption• RS485 Modbus TCP communication• Flexible wiring and connection
• SFS 16, 24 String supervisorstructure mountedIEC compliance string supervisor that can monitor from 8 to 24 individual channels. It is suitable to be mounted over the structure of the PV panels..
• SFS 8 String supervisor IEC compliance string supervisor that can monitor 8 individual channels. Two strings can be combined in a single channel duplicating the box capacity.
07.
FR
EE
SUN
AC
CE
SSO
RIE
S
STRING SUPERVISOR BOXES
106_107
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
OrderingInfo&Standards
108_109
FREESUN SOLAR INVERTER / POWER ELECTRONICS
FREESUN SERIES
LVT SERIES HE SERIES
Output Power
0080 80kVA0100 100 kVA
... ...1500 1500kVA
Inverter Location
I IndoorO Outdoor Outdoor HES-S (Standard concrete station)R - Outdoor HES-R (Reduced concrete station)C - Outdoor HEC inverter P Outdoor HEC Inverter w/ integrated DC subsystemT Outdoor HET (ISO container station)K - Outdoor Open Skid station
Topology
T Low Voltage Transformer (LVT Series) -H - IEC High Efficiency InverterU UL High Efficiency InverterB UL High Efficiency PCSS IEC High Efficiency PCSJ - JP High Efficiency Inverter
Maximum input voltage
06 600VDC09 900VDC10 1000VDC
Isolating monitoringA Adjustable isolation between (+), (-) and earthN Negative of the photovoltaic installation earth connectedP Positive of the photovoltaic installation earth connected
Lightning and overvoltage protections
N Without overvoltage protectionV With AC and DC overvoltage protectionR With AC and DC overvoltage protection and lightning protection
Output voltage
0 - 390VAC - (UL SERIES)1 - 360VAC2 - 330VAC3 - 300VAC4 270VAC5 240VAC -6 - 208VAC - (UL SERIES)7 - 380VAC (HEC Gen II)8 - 400VAC (HEC Gen II)
Auxiliary supplyN Not includedF With auxiliary 24VDC power supply for String Supervisor 8 (SFS08)
Humidiy ControlN Not includedR With heating resistorsA Active Heating
Medium Voltage Output
15 - 15kV20 - 20kV22 - 22kV24 - 24kV30 - 30kV33 - 33kV36 - Under request [1]
MPPt Configuration[1]
1 - 1MPPt2 - 2MPPt… - ...10 - 10MPPt
OtherI - Left side - AC module
.. Under request
[1] The maximum number of MPPt´s depends on the number of modules implemented in each inverter with a maximum of one or two MPPt per module. This is an optional kit configured according to the MPPt number and Inverter Serie.
NOTES
HE - LVT ConfigurationTable
EXAMPLECODE: FS 0100 c H 10 a N 2 N N - 2
110_111
08.
OR
DE
RIN
G IN
FO
& S
TAN
DA
RD
S
HE - LVT Standards
HE-HEC SERIES
REGULATIONS
CE conformity LVD Directive 2006/95/CE - EMC Directive 2004/108/CE EMC EN 61000-6-2,-4; EN 61000-3-4 Safety EN 62109-1,-2 (Certified by SGS) ; EN 62271-202, -200 [1]
International Standards IEC 62109-1; IEC 62109-2; IEC 62116 (Anti Islanding)Grid Connection Germany BDEW MV Guideline Spain RD 1699/2011, P.O. 12.3, Italy CEI 0-16 [2]
France Arrêté du 23/04/08 Romania ANRE Interconnection Code United Kingdom G59/3 [3]
Israel IEC (Israel Electrical Company) listed Puerto Rico PREPA Technical Requirements South Africa RSA Renewable Grid Code Mexico General requirements for National Electric System connection Hawaii Heco Technical requirements Other countries and regulations Consult Power Electronics
LVT SERIES
REGULATIONS
CE conformity LVD Directive 2006/95/CE; EMC Directive 2004/108/CE EMC EN 61000-6-1,-2,-3,-4; EN 61000-3-4; EN 61000-3-12 Safety IEC/EN 62109-1 (Certified by TÜV); IEC 62109 -2Grid Connection Germany VDE-AR-N 4105 Spain RD 1699/2011, P.O. 12.3 Italy CEI 0-21 France UTE C-15-712-1 United Kingdom G59/3 Israel IEC (Israel Electrical Company) listed ; >51kW Other countries and regulations Certificate VDE 0126-1-1, Consult Power Electronics.
HEC-UL SERIES
REGULATIONS
Safety UL 1741; CSA 22.2 No.107.1-01 [4]Utility Interconnect IEEE 1547Grid support ( optional) LVRT, Active & Reactive Power Control, etc.Efficiency CEC testing
FREESUN HE, HES, HEc
FREESUN HEc-UL
FREESUN LVT
FacToRy INSpEcTIoN by aENoR aNd cSa
[1] Applicable for medium voltage side HES series.[2] For the entire fulfilment of regulation CEI 0-16 it is required to add the following external protection devices approved by ENEL.• General Protection Device (according to DK 5600)• Interface Protection Device (according to DK 5740)The customer is responsible of both the correct selection and installation of these devices.[3] For the entire fulfillment of regulation G59 it is required to add external hardware that are not PE scope of supply. The client is responsible of both the correct selection and installation.[4] On certification process.
NoTES
FREESUN SOLAR INVERTER / POWER ELECTRONICS
ENGINEERING SUPPPORTPower Electronics offers pre-sales support to EPCs, developers, operators and investors, because our success is based on your satisfaction. Power Electronics customizes our products to comply with your stringent requirements, thanks to the vertical integration of our production line and our dedicated engineering department.
Power Electronics supports you during the whole documentation submission process and factory acceptance test protocols. Power Electronics helps you during all the project stages to get all the work done on time.
FREE COMMISIONINGPower Electronics includes free equipment commissioning in every proposal worldwide, covering: correct installation, correct AC, DC and data cabling, communications tests, and inverter parameters setting. Power Electronics personnel start the inverters and train the operator(s) on the basic inverter parts and relevant settings. No matter the time or the units, because we believe in a well performed job.
COMPRENHENSIVE 5 YEAR FACTORY WARRANTYPower Electronics offers 60 months factory warranty from the date of commissioning (Annex I). Power Electronics will repair the defective parts, if feasible, within the next 24h or 48h (depending on the country) after the client’s notification without any cost to the client. The factory warranty covers Power Electronics costs for labor and materials necessary to reestablish trouble free operation. Additionally Power Electronics warranty includes free of charge: • 24/7d Remote monitoring & customer support • 24h/7d on-site technical service
6-10 YEAR FACTORY WARRANTY EXTENSION PACKAGESPower Electronics offer 60 months extension factory warranty packages with a maximum of 25 years from the date of commissioning. The extension warranty will be invoiced yearly and covers the services described in the general factory warranty.
PowerOn Support
POWER ON SUPPORT is the concept which explains the customer oriented strategy implemented by Power Electronics since its origins more than 25 years ago. We do not simply consider ourselves an advanced power electronics manufacturer, but a service company which takes care of all our customers’ needs and adapt to their requirements.
We know that each location, project and client is different, that’s why Power Electronics addresses each single request by customizing modular services comprising warranty extensions, maintenance and spare parts contracts. This document explains the available service packages that aim to get the maximum yield and reliability for your facilities.
OPTIONAL WARRANTY
112_113
01.
PR
ESE
NTA
CIÓ
N
09.
PO
WE
R O
N S
UP
PO
RT
24h/7d REMOTE MONITORING & CUSTOMER SUPPORTPower Electronics offers real time remote monitoring and assistance. Experience engineers from our HQ in Valencia will detect and aware you from premature failures or inverter underperformance. We are willing to get the maximum yield to those who trust us.This service is complimentary during warranty period.
24h/7d ON-SITE TECHNICAL SERVICEPower Electronics does not have customer categories or preferred areas we offer an on-site service response within 24h/7d given by Power Electronics trained personnel when a remote assistance is not enough. The on-site technical assistance covers Power Electronics costs for labor and materials necessary to reestablish trouble free operation.This service is complimentary during warranty period.
MAINTENANCE CONTRACTTo extend the end of life of the inverter, Power Electronics offers a maintenance plan that includes components replacement and cleaning, firmware update and inverter inspection. Maintenance contracts are agreed and customized to the possibilities of the client and the PV plant location.
SPARE PARTS WARRANTYBe confident over the entire PV plant life cycle, Power Electronics offers under the period agreed floating and updated spare parts stock. The scope of the spare parts warranty includes the equipment listed in Annex III, exworks conditions and a shipping time from 24h-48h that can differ depending on the location. Labor cost are not included if the warranty of the equipment is expired.
99% INVERTER TECHNICAL AVAILABILITYPower Electronics offers 99% inverter technical availability contracts services free of charge. Our unique inverter topology, manufacturing quality controls and 24/7d on-site repair service make it possible.
If required, Power Electronics will deliver an annual report evaluating the technical availability by Power Electronics..
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
ReferencesWietzendorf - Naundorf (Germany) FREESUN HES 5MW
114_115114_115
10.
RE
FE
RE
NC
ESGreat Glemham (United Kingdom)
FREESUN HEC 17.6MW
Marley Thatch (United Kingdom)FREESUN HES-R 6.2MW
FREESUN SOLAR INVERTER / POWER ELECTRONICSFREESUN SOLAR INVERTER / POWER ELECTRONICS
Marino Pole,Blagoevgrad (Bulgary)FREESUN HEC 8MW
Los Puquios SPA (Chile),FREESUN HEK 2.8MW
116_117116_117
Zouerate (Mauritania), FREESUN HET 3MW
Kladruby (Check Republic)FREESUN HEC 3.8MW
10.
RE
FE
RE
NC
ES
FREESUN SOLAR INVERTER / POWER ELECTRONICS
Warranty POWER ELECTRONICS guarantees supply against any anomaly which can be directly and exclusively attributed to design, fabrication, manufacture or material defect, thus in case those faults or defects are identified before the end of warranty, POWER ELECTRONICS undertakes to repair them in a maximum time span of 24/48h. POWER ELECTRONICS provides its clients with a 24h/365 days a year technical service. Lacking a specific agreement in particular terms, the period of the warranty is of FIVE years. In application of that warranty, POWER ELECTRONICS commits to repair or replace the faulty parts. The client must communicate to POWER ELECTRONICS immediately any obvious defect, describing its nature in detail and allowing POWER ELECTRONICS to control and correct this fault. The possible expenses caused by transport, customs, expenses, etc and those related to dismounting and assembling the corrected or substituted part, will be covered by POWER ELECTRONICS, except in those cases in which the client whishes to carry out those tasks with the previous approval by POWER ELECTRONICS, which no cost for the manufacturer.
The warranty will only be valid when the transport, storage, assembly, installation, commissioning, functioning and maintenance in the delivery have all been carried out correctly by authorized personnel and in accordance with the enclosed instructions manual. The warranty exclusively includes the repair of defects and/or exchange of faulty parts on our own products. The warranty will be void in normal cases of wear and tear, being ordinary caused by functioning or external causes, or extraordinary caused by an overcharge of work load, wrong use or external causes as can be excessive humidity, dust, corroding products, electromagnetic fields, static energy, fluctuations in the quality of the electrical supply, etc. And, does not cover defects caused by accidents, by transport, inadequate storage or conservation, and in general faults which are not attributable or are out of POWER ELECTRONICS’ control.
The client does not have authorization to personally repair, or do so through a third party, nor can he send the equipment to be corrected or replaced, without the specific authorization by POWER ELECTRONICS. The warranty will be void if the client or any third parties make any intervention, modification, or repair without the previous written consent by POWER ELECTRONICS, or if they do not fulfill the immediate requirements to avoid an aggravation of the damage. The warranty will not cover in any case the damage, whether direct or not, to people or objects, and in no case will the faulty equipment include compensation or payment for lack of productivity by the client or by the final user, and this is the only warranty given to the client, substituting any previous mentioned conditions or warranty, both implicit and legal, which have not been expressly accepted by POWER ELECTRONICS. The warranty always frees POWER ELECTRONICS from having to answer to faults which occur after the mentioned period. The repair or replacement of a faulty equipment at arrival will not modify the initial date of the warranty period for the global equipment. The substituted equipment will be property of POWER ELECTRONICS.
Optional additional WarrantiesIn Power Electronics we believe in the quality and durability of our inverters. That is why we offer an all inclusive 5 year warranty on our equipment. We know that the inverter is the heart of the installation and it must never stop, this is why we have made our top priority to create a strong and competitive inverter and give you the best service and warranty along with it. During those 5 years you won’t have to pay any technical service or advice, even when made on site, and this is the best insurance for your investment. Extended warranty packages up to 25 years are also available.
118_119
11.
WA
RR
AN
TY
/ C
ON
TAC
T
Contact24H/7D
TECHNICAL ASSISTANCE
HEADQUARTERS - VALENCIA - SPAIN
C/ Leonardo da Vinci, 24 - 26 - Parque Tecnológico - 46980 - PATERNA - VALENCIA - SPAIN Tel. 902 40 20 70 - Tel. (+34) 96 136 65 57 - Fax (+34) 96 131 82 01
INTERNATIONAL SUBSIDIARIES
AUSTRALIA• Power Electronics Australia Pty Ltd - U6, 30-34 Octal St, Yatala, • BRISBANE • QUEENSLAND 4207• P.O. Box 6022, Yatala DC, Yatala Qld 4207 • AUSTRALIA • Tel. (+61) 7 3386 1993 • Fax (+61) 7 3386 [email protected]
BRAZILPower Electronics Brazil Ltda - Rua Odeon, 102 - Centro • CEP 09720-290SÃO BERNARDO DO CAMPO • SP • BRASIL • Tel. (+55) 11 5891 9612 • Tel. (+55) 11 5891 [email protected]
CHILE• Power Electronics Chile Ltda • Los Productores # 4439 • Huechuraba • SANTIAGO • CHILETel. (+56) (2) 244 0308 · 0327 · 0335 - Fax (+56) (2) 244 0395• Oficina Petronila # 246, Casa 19 - ANTOFAGASTA • CHILE • Tel. (+56) (55) 793 [email protected]
CHINA• Power Electronics Beijing - Room 606, Yiheng Building • No 28 East Road, Beisanhuan • 100013, Chaoyang District, BEIJING - R.P. CHINA • Tel. (+86 10) 6437 9197 • Fax (+86 10) 6437 9181 • Power Electronics Asia Ltd - 20/F Winbase Centre - 208 Queen’s Road Central • HONG KONG • R.P. [email protected]
GERMANY• Power Electronics Solar GmbH - Dieselstrasse, 77 • D·90441 • NÜRNBERG • GERMANYTel. (+49) 911 99 43 99 0 • Fax (+49) 911 99 43 99 [email protected]
INDIA• Power Electronics India - N.5, Cunningham Crescent, 1st floor.Bangalore 560052 - INDIA Tel./Fax +91 80 6569 [email protected]
ITALY• Power Electronics Italia Srl - Piazzale Cadorna, 620123 • MILANO • ITALIA • Tel. (+39) 342 50 73 691 [email protected]
JAPAN• Power Electronics Japan KK - Nishi-Shinbashi 2-17-2 - HF Toranomon Bldg. 5F 105-0003 • Minato-Ku • TOKYOTel. (+81) 03 6355 8911 - Fax (+81) 03 3436 5465 [email protected]
KOREA• Power Electronics Asia HQ Co - Room #305, SK Hub Primo Building - 953-1Dokok-dong, Gangnam-gu - 135-270 • SEOUL • KOREATel. (+82) 2 3462 4656 • Fax (+82) 2 3462 4657 [email protected]
MEXICO• P.E. Internacional Mexico S de RL - Avda. Tejocotes lote 76 A S/N • San Martin Obispo Tepetlixpa • CP 54763 • CUAUTITLAN IZCALLI • MEXICOTel. (+52) 55 5390 8818 • Tel. (+52) 55 5390 [email protected]
MOROCCO• Power Electronics - Ekoakua • Geea sarl , N°184 Bloc Hay EL.Massira Aït Melloul •CP 80150 • Agadir • MAROCTel. + 212 5 28 24 04 57 • Mob. (+34) 628 11 76 [email protected]
NEW ZEALAND• Power Electronics New Zealand Ltd - 12A Opawa Road, Waltham - CHRISTCHURCH 8023• P.O. Box 1269 CHRISTCHURCH 8140 • NEW ZEALANDTel. (+64 3) 379 98 26 - Fax.(+64 3) 379 98 [email protected]
SOUTH AFRICA• Power Electronics South Africa Pty Ltd • Central Office Park Unit 5 • 257 Jean AvenueCenturion 0157 • SOUTH AFRICATel. (+34) 96 136 65 57 • Fax (+34) 96 131 82 01 [email protected]
TURKEY• Perpa Ticaret Merkezi A Blok Kat:2 No:9/0034 - 34384 Okmeydanı Şişli • Istanbul • TURKEYTel: 0 212 221 48 48 (124) • Fax 0 212 221 17 [email protected]
UNITED KINGDOM• Power Electronics UK Pty Ltd· Wells House, 80 Upper Street, IslingtonLondon, N1 0NU · 147080 Islington 5 • Tel. (+44) 149 437 00 [email protected]
UNITED STATES• Power Electronics USA Inc. • 505 Montgomery Street, 11th Floor San Francisco • CA 94111 • USATel. (415) 874-3668 • Fax (415) 874-3001 • Mob.(415) [email protected]
FSC
A0
2CI
P
OW
ER
ELE
CT
RO
NIC
S r
eser
ves
the
rig
ht t
o m
od
ify
who
le o
r p
art
of
the
cont
ent
of
this
bro
chur
e at
any
tim
e an
d w
itho
ut p
rio
r no
tice
. May
20
14
www.power-electronics.com
VAR
IAD
OR
ES
DE
VE
LOC
IDA
D