www.financenorway.com The Global Fire Sprinkler Industry 2017: Threats and Opportunities March 2017 By Nick Groos, Minimax Viking

Transcript of The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design...

Page 1: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

The Global Fire Sprinkler Industry 2017:

Threats and Opportunities March 2017

By Nick Groos, Minimax Viking

Page 2: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

New Sprinkler Technology

2

Page 3: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 3

4 m

2 m

Test 1: Pressure = 0.5 bar

Density = 3.2 mm/min

Flow = 51 liters / min

Minimum Pressure = 0.5 bar

Minimum Density = 2.04 mm/min

Max Area of Coverage = 37 m²

2.5 m

5 m

Test 2: Pressure = 0.5 bar

Density = 2.04 mm/min

Flow = 51 liters / min

Page 4: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 4

Page 5: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

New Sprinkler Technology

5

• Major Trends => Application Specific

Examples

Attic Sprinklers

Interstitial Spaces

Corridor Sprinklers

Institutional

=> Electrification

Page 6: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 6

Facts

2.461 billion

and DHL – Low Cost Sensors 12/2013

2.461 billion 1.555 billion

Source: DHL – Low Cost Sensors 12/2013

Real

World

Page 7: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 7

Page 8: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 8

deliver the

agent,

to the right

place,

at the

right time,

in the right

amount,

for the right

duration

Detect the

fire and,

Page 9: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 9

FM Global photo (courtesy of Terex MHPS Corp)

Page 10: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

RoR HD RoR HD RoR HD TC TC TC

CONCLUSIONS

- Quick Suppression

- Limited Damage

- Small Fires

- Accurately Located

- Low Water Densities

Solenoid Valve Solenoid Valve Solenoid Valve

Page 11: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 11

Source: RFiD Journal

Page 12: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 12

Page 13: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

NFPA 13 Extended Coverage Sprinklers

Sprinkler

Type

K-Factor Design

Sprinklers

Area of

Coverage

Flow per

Sprinkler

Min. Pressure Sprinkler Flow No. of Sprinklers

Standard K160 12 12,1 sqm. 114 lpm 0,50 bar 1.370 lpm 369

Ext. Cov. K202 6 23,8 sqm. 148 lpm 0,54 bar 886 lpm 188

Ext. Cov.

K202 5 37,2 sqm. 227 lpm 1,27 bar 1.136 lpm 120

Design and Calculation Examples

Building: 4.460 sqm., 7m. high smooth, flat ceiling

Hazard: Ordinary 1, Wet Pipe System

Sprinkler Design Area: 139 sqm.

Design Density: 6,1 mm/min

Page 14: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

☺ Appropriate for the Risk?

☺ Built In Safety Factors?

☺ Component Approval?

☺ Factory Production Control?

Page 15: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

0

200 000

400 000

600 000

800 000

1 000 000

1 200 000

1 400 000

Brazil2009

Brazil2012

India2011

India2013

Amounts coming fromcountries where non-certified sprinklers areproduced

13 %

59 %

34 %

6 %

Fire Sprinkler Market Statistics: Brazil and India

Page 16: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Question: Does…………

Page 17: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

IFSA Test Reports on Non-Approved Sprinklers

Page 18: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Corrosion

18

• Sources => EFSN

“Corrosion in Sprinkler Systems” February 2013

=> FM Global

“Corrosion and Corrosion Mitigation in Fire

Protection Systems” 2nd Edition, July 2014

=> SINTEF

“Corrosion in water filled galvanized pipes”

Page 19: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 19

Corrosion

Examples Source: FM Global, Minimax

Page 20: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Types of Corrosion

20

O2 O2= MIC X “In many cases, the presence of MIC-related bacteria may exert SOME

influence on corrosion of fire protection systems, BUT NOT AS the major

corrosion contributor.”

SOURCE: “Corrosion and Corrosion Mitigation in Fire Protection Systems”,

FM Global, 2nd Edition, July 2014 (emphasis added)

Page 21: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Types of Corrosion

21

O2

Dry Pipe

Pre-Action

Page 22: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Corrosion Mitigation – FM Global (Datasheet 2-1)

22

For Wet Pipe systems (FM Datasheet 2-1, 2.2.1.8)

Remove trapped air from wet-pipe sprinkler systems. Install minimum 1/2 in. (13 mm) FM

Approved automatic air-release valves or FM Approved manual

valves at the system high points. Remove the air after each time the

system is drained and refilled.

Page 23: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Corrosion Mitigation – FM Global (Datasheet 2-1)

23

For Dry and Pre-Action Systems using Nitrogen (FM

Datasheet 2-1, 2.2.1.10.1)

A. Pressurize the system using an FM Approved nitrogen

generator. Alternatively, nitrogen cylinders maybe used, or another suitable supply if

compressed air is provided as backup.

B. Black steel pipe is acceptable in dry-pipe and preaction sprinkler systems

if nitrogen will be used throughout the life of the system. If it

will not, use galvanized steel pipe.

Page 24: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Corrosion Mitigation – FM Global (Datasheet 2-1)

24

For Dry and Pre-Action Systems NOT using Nitrogen (FM

Datasheet 2-1, 2.2.1.10.1)

A. Use galvanized steel pipe.

E. Avoid the use of rolled groove joints. Rolled groove joints in a dry

sprinkler system promote water accumulation that can result in corrosion sites.

F. In humid regions or in areas that are subject to rapid drops in temperature, install an

air-drying system …

H. Orient longitudinal pipe weld seam toward building roof;

at least 45° in relationship to the floor (for reference, the weld line points to the floor at 0°) to

mitigate pipe weld seam corrosion.

Page 25: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Thank you, and………………………….

Support your local Sprinkler Trade Association!

25

Page 26: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

SUPPORTING MATERIAL

26

Page 27: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Non-Certified Sprinkler Testing

Flow Endurance Test - FAILED

• 13,8 bar pressure of water is applied for

a period of 30 minutes.

• Substantial deflector deformation

occurred in both samples.

After Before

Page 28: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Non-Certified Sprinkler Testing

Sprinkler Operation - FAILED

• Heat responsive element either

operated slowly or not at all.

• Lodgment occurred in a vast majority

of the samples tested.

• Water was discharged up towards

the ceiling rather than down towards

the fire.

Page 29: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

Non-Certified Sprinkler Testing

Sealing Assembly - FAILED

• Use of an O-ring seal banned

since 10+ years.

• Non-operation as well as leakage

can occur in field installation

environments.

Page 30: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

30

Non-Certified Sprinkler Testing

Lodgment Test - FAILED

Page 31: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com

31

Non-Certified Sprinkler Testing

RTI Value - FAILED

Page 32: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 32

Non-Certified Sprinkler Testing

Assembly Load - FAILED

Page 33: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 33

Non-Certified Sprinkler Testing

Rough Usage - FAILED

Page 34: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 34

Non-Certified Sprinkler Testing

Distribution Test - FAILED

Page 35: The Global Fire Sprinkler Industry 2017: Threats and ...€¦ · Sprinkler Type K-Factor Design Sprinklers Area of Coverage Flow per Sprinkler Min. Pressure Sprinkler Flow No. of

www.financenorway.com 35

Non-

Certified

Sprinkler

Testing

Wood Crib

Fire Test -

FAILED