The birth of a new eraExcellent neonatal respiratory supportat your fingertips

DRÄGER BABYLOG® VN500

D-22136

-200

9

02 |

Because we’ve been so closely involved with neonatalmedicine for decades, we understand the problemsand challenges faced by neonatal care specialists.With the new ventilation unit Babylog VN500, part of the IACS Workstation Neonatal Care, Dräger is entering a new era in neonatal ventilation. TheBabylog VN500 provides excellent conventionalventilation and High Frequency Oscillation combinedwith an intuitive user interface operated by a colortouch screen. All of this is based on an entirely new platform that will bring innovative technology to neonatal care today.

DEDICATED TO NEONATAL VENTILATION

At Dräger, we’re convinced that improved quality and higher performance don’t have to translate toincreased complexity. The neonatal care environmentis fast-paced, and we know that caregivers haveenough to think about without having to spend hourslearning how to use new technology. Our goal is to give you the tools you need to provide state-of-the-art care without increasing your workload.

The Babylog VN500 combines years of experienceand know-how with the latest innovative technologyto create a complete, integrated neonatal ventilationsolution that can help you move on toward new frontiers.

To be successful, it takes special commitment to thequality of care required to manage these patients.This is particularly true for mechanical ventilation. To avoid pulmonary injury, immature lungs andunderdeveloped breathing regulation mechanismsrequire extremely gentle ventilation, advancedrecognition and compensation technology. Highrespiration rates and tiny tidal volumes demand themost accurate delivery possible to ensure correctminute volumes.

Neonatal ventilation is highly complex and challenging. Caring for these smallpatients is one of the most demanding tasks imaginable, but sending them home after spending days, weeks or even months in a NICU is one of the most rewarding experiences modern medicine has to offer.

One of the greatest challenges in medicine

DRÄGER BABYLOG® VN500

MT-1166

-200

5

| 03

Introducing the Dräger Babylog® VN500

DRÄGER BABYLOG® VN500

Excellence in neonatal

r espiratory support

World-class conventional

neonatal ventilation

Non-invasive nasal CPAP andoxygen therapy

Intuitive userinterface with

color touch screen

Smart Pulmonary View

Flexible transportand backup solution

Powerful HighFrequencyOscillation

D-259

30-200

9

A component of the Infinity® Acute Care SystemTM

Workstation Neonatal Care

– The Babylog VN500 offers extensive neonatalventilation therapy, including powerful HighFrequency Oscillation, excellent conventionalventilation, nasal CPAP and high flow oxygentherapy. All in one device. And it does not stopthere. Additional ventilation therapy features suchas Volume Guarantee, PC-MMV1), ATC2) andautomatic leakage compensation extend yourtherapy options on the NICU and help to furtherimprove the quality of care you can provide.

– High Frequency Oscillation combined with VolumeGuarantee maintains and delivers a consistent andconformable tidal volume to the baby. The smartVolume Ventilation option combines consistency,patient comfort and feedback to the user in case of changing patient conditions.

– Smart Pulmonary View® is one of a growingnumber of Dräger Smart applications, developed to help to reduce your cognitive workload.

Extend your therapy options: The innovative features of the Babylog® VN500 turn data into information and greatly expand your therapeutic potential.

Smart

04 | DRÄGER BABYLOG® VN500D-27780

-200

9

(1) Pressure Control - Mandatory Minute Ventilation (2) Automatic Tube Compensation

Technologythat works for you

– Integrated process support, such as anautomated suctioning maneuver, an automaticday/night screen function, combined with highlycustomizable user interfaces help you streamlineyour workflow.

– The Babylog VN500 comes with an contextsensitive help function that puts the informationyou’re looking for right on the screen. Needassistance getting started? Preparing theBabylog VN500 couldn’t be easier. Follow theonline help function to prepare the ventilator for use. The Infinity® ID technology providesdetection software to avoid circuit misconnectionerrors and enables reminders when it’s time toreplace the patient circuit per departmentalpolicy.

– Our automatic leakage compensation featuremaintains sensitive and accurate synchronizationeven in the face of significant endotracheal tubeleakage.

– Apnea Ventilation with AutoReturn provides stable minute ventilation in case of apnea and isautomatically discontinued as soon as sufficientspontaneous breathing is detected.

| 05DRÄGER BABYLOG® VN500

D-21994

-200

9D-27782-200

9

06 |

– The Babylog VN500 comes with an internalbattery, as power back up and for intra-hospitaltransport. This keeps you independent from anexternal power supply for up to 30 minutes whiledelivering the same, high-quality ventilation.

– For extended intra-hospital transport, the optionalPS500 mobile power supply can provide you at least 100 minutes of additional power.

– The electrically driven GS500 mobile air supplyprovides medical air for extended independencefrom central compressed air systems. This optional air supply unit gives you addedventilation flexibility without compromising onquality of care.

– The optional Transport Supply Unit (TSU),equipped with cylinder holder, quickly attaches tothe Babylog VN500 trolley, allowing flexible, safeand easy transport.

Make technology available wheneveryou need it: Uninterrupted, high-qualityventilation during transport is anessential part of modern care.

Mobile

– With optional hardware and software upgrades,you can increase the range of functionality tobetter suit your specific needs. Add HighFrequency Oscillation, Volume Ventilation – thereare numerous possibilities to choose from.

– GS500 air supply and PS500 power supply canbe added to increase mobility and to provide areliable backup in case of interruptions in thecentral gas or power supply.

Expand your system to suit your needs:The Babylog® VN500 is equipped withstandardized interfaces for optimal components, it offers you true scalabilityand flexibility.

Scalable

DRÄGER BABYLOG® VN500

Entera new world of

neonatal ventilation

D-22316-200

9

D-27783

-200

9

| 07DRÄGER BABYLOG® VN500

– Our Infinity® Acute Care System™ approachfocuses on your workflow and clinical processoptimization. It’s designed to help reducecomplexity and overcome technical limitations. As a component of this system you will be able to apply innovative new technology to neonatalcare now and in the future.

– In the NICU the Babylog VN500 can provideflexible mounting solutions to optimize yourworkplace ergonomics. Its low noise levels (<_ 45 dB(A)) support a calm and comfortableenvironment for the baby.

– The modular Infinity® Service Concept can betailored to your specific needs. Everything frombasic to comprehensive maintenance plans isavailable. These packages help you to get themost out of your fleet of Infinity® devices.

Optimizing your workflow: The Babylog®

VN500 is a component of the Dräger Infinity® Acute Care System™.

Integrated

– The Babylog VN500 uses the new user interfacedeveloped for the next generation of Drägerdevices. Together with the rotary knob, the colortouch screen lets the user navigate through thelogical and intuitive menu structure. Just touch,turn and confirm.

– The Babylog VN500 can be individuallyconfigured to suit your needs. You can chooseyour own screen options, standard ventilatorsettings and alarm configurations. Then, you caneasily and rapidly transfer configurations betweenBabylog VN500 devices using a USB memorystick. This feature can save you valuable timewhen standardizing configurations across yourentire unit.

Configure your fleet quickly and easily:A high level of standardization translatesto rapid familiarization.

Standardized

D-22307-200

9

90 66 225 | 09.10-3 | Marketing Com

munications | LSL | LE

| Printed in G

ermany | Chlorine-free –

environm

entally com

patible| Subject to

modifications

| © 2010 Drägerwerk AG & Co. KGaA

Manufacturer:Dräger Medical GmbH23542 Lübeck, GermanyThe quality management system atDräger Medical GmbH is certifiedaccording to ISO 13485, ISO 9001and Annex II.3 of Directive93/42/EEC (Medical devices).

HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germany

www.draeger.com

REGION EUROPE CENTRAL AND EUROPE NORTHDräger Medical GmbH Moislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPE SOUTHDräger Médical S.A.S. Parc de Haute Technologie d’Antony 225, rue Georges Besse92182 Antony Cedex, FranceTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]

REGION MIDDLE EAST, AFRICA, CENTRAL AND SOUTH AMERICADräger Medical GmbHBranch Office DubaiDubai Healthcare CityP.O. Box 505108Dubai, United Arab EmiratesTel + 971 436 24 762Fax + 971 436 24 [email protected]

REGION ASIA / PACIFICDraeger Medical South East Asia Pte Ltd25 International Business Park#04-27/29 German CentreSingapore 609916, SingaporeTel +65 6572 4388Fax +65 6572 4399 [email protected]

REGION NORTH AMERICADraeger Medical, Inc.3135 Quarry Road Telford, PA 18969-1042, USATel +1 215 721 5400Toll-free +1 800 437 2437Fax +1 215 723 [email protected]