The AMIGO Project: An Advanced Multi-ModalityImage-Guided Operating Suite
Randy Ellis, Ph.D.
©2005 Surgical Planning Laboratory, ARR Slide 2
AMIGO: Phase II Layout
©2005 Surgical Planning Laboratory, ARR Slide 3
AMIGO: Central Operating Room
©2005 Surgical Planning Laboratory, ARR Slide 4
AMIGO: Phase I View to 3T MRI
©2005 Surgical Planning Laboratory, ARR Slide 5
AMIGO: Phase II View to PET/CT
©2005 Surgical Planning Laboratory, ARR Slide 6
AMIGO Applications, Phase I (2005-2006)
BRAIN: FUS (MRI, fMRI, DTI, T-MRI)
BRAIN: Open Surgery (MRI, fMRI, DTI,US)
BREAST: MRI-Guided Lumpectomy(MRI,3D-US,4D MRI of contrast
uptake)
BRAIN: Skull Base Surgery (MRI, fMRI, DTI, CT, US, Endoscope)
©2005 Surgical Planning Laboratory, ARR Slide 7
AMIGO Applications, Phase II (2006-2007)
BREAST CANCER: FUSLIVER THERMAL ABLATIONKIDNEY THERMAL ABLATIONCERVICAL CANCER BRACHYTHERAPYBONE METASTATSIS THERMAL ABLATIONBONE TUMOR FUSVERTEBROPLASTYPROSTATE BIOPSYPROSTATE BRACHYTHERAPYPROSTATE FUS
©2005 Surgical Planning Laboratory, ARR Slide 8
AMIGO Applications, Phase II (2007-2008)
SPINE SURGERY NEUROVASCULAR INTERVENTIONS CRANIOFACIAL SURGERYLIVER ENDSOCOPIC SURGERYKIDNEY FUS LUNG THERMAL ABLATIONLUNG BRONCHOSCOPYJOINT ENDOSCOPIC SURGERYCARDIAC EP ABLATION AVM EMBOLIZATION, AVM FUS
©2005 Surgical Planning Laboratory, ARR Slide 9
Image Intensive Environment
• Preoperative images:– diagnostic & planning
• Intraoperative images:– Updating anatomical changes
– Functional monitoring
• Postoperative images:– Verification
©2005 Surgical Planning Laboratory, ARR Slide 10
Imaging Modalities
Unite modalities in a patient coordinate frame:
• MR for soft tissues• PET for metabolic imaging• CT for bone surfaces• Fluoroscopy for updates• 3D ultrasound for soft tissues• Microscopes/endoscopes for sight• 1D signals (EEG, ECG, etc.)
©2005 Surgical Planning Laboratory, ARR Slide 11
Integrated Imaging and Intervention
+ Image/patient registration problem disappears
+ Real-time monitoring of procedures
- Visualization challenges
+ Multi-system assessment and treatment
©2005 Surgical Planning Laboratory, ARR Slide 12
Interoperability is Key
- Information management
• Maintain registration across rooms
• Multiple software systems
– GE/NAV for established procedures
– 3D Slicer, etc. for novel applications
• Multiple localization technologies
– Primarily EM & optical
– Robot also localizes
©2005 Surgical Planning Laboratory, ARR Slide 13
The AMIGO Navigator: An Overview of the Software Development Process
Randy Ellis, Ph.D.
©2005 Surgical Planning Laboratory, ARR Slide 14
Software is Expensive and Complex
• 31% were abandoned before
delivery
• Over 57% were a minimum of
189% over budget
Since then: overall, limited progress
Source: The Standish Group
An extensive 1994 study of thousands of US industrial projects found:
©2005 Surgical Planning Laboratory, ARR Slide 15
Our Guiding Principles
• Open Source:– Collaborative process– Free to commercialization
• Robust:– Use NAMIC/Kitware infrastructure– Automated testing of all changes
• Extensible:– Gain from ongoing Slicer activities– Expect to add new imaging modalities– Expect new interventional procedures
©2005 Surgical Planning Laboratory, ARR Slide 16
Application-Oriented Architecture
Base (common) software
MR
I Bio
psy a
pp
.
Neu
rosu
rgery
ap
p.
Bre
ast S
urg
ery
ap
p.
©2005 Surgical Planning Laboratory, ARR Slide 17
Storyboards for Applications
• Define the basic approach to the interventional procedure
• Prototype screen appearances (paper cartoons or PowerPoint are useful)
• Specify screen-to-screen actions
• Implement “happy-day” scenario
• Elaborate alternative workflows (e.g., error handling, new image acquisitions)
Result: fast development of well tested software
Engineer and clinicians work together:
©2005 Surgical Planning Laboratory, ARR Slide 18
Technical Overview
• Requirements drive the process• Application-specific:
– Rapid specification of ideal workflow– Catch design problems early– Elaborate necessary extensions only, not
all possible variants• Test-oriented:
– The specification produces tests before code is written
– Repeat all tests whenever changes are made
Result: robust, trustable systems
©2005 Surgical Planning Laboratory, ARR Slide 19
Example Application:
CT-Guided Brain Tumor Biopsy
©2005 Surgical Planning Laboratory, ARR Slide 20
Clinical Problem: Biopsy in CT Scanner
Idea:
• Perform brain biopsy using 2D slices
Technique:
• Attach fiducials to head holder
• Scan holder and patient
• Select slices showing structures at risk
• Superimpose needle trajectory on slices
• Verify biopsy with new CT acquisition(s)
©2005 Surgical Planning Laboratory, ARR Slide 21
CT Biopsy Phase 1: Procedure Workflow
1. Prepare patient (including fiducials)
2. Transfer patient to CT scanner
3. Acquire the CT scan (?inject?, image)
4. Load scan into Navigator
5. Software calculates registration
6. Software displays needle trajectory in CT
7. Perform the biopsy
8. Close the patient
©2005 Surgical Planning Laboratory, ARR Slide 22
CT Biopsy Phase 2: Software Actions
1. Load instrument descriptions
2. Load CT scan
3. Detect fiducials
4. Calculate registration
5. Select key CT slices
6. Track the needle guide
7. Overlay needle trajectory on slices
©2005 Surgical Planning Laboratory, ARR Slide 23
CT Biopsy Phase 3: Procedure Steps
1. Screen to select scan from disk
2. Screen to give registration progress
3. Screen to select CT slices
4. Screen to display navigation
Additional Requirements:
– Forward/backward buttons
– Exit button
– Tool status display (e.g., visibility)
©2005 Surgical Planning Laboratory, ARR Slide 24
LOAD SELECT NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
CT Biopsy Storyboard: File Selection
All we need here is a simple dialog box
©2005 Surgical Planning Laboratory, ARR Slide 25
LOAD SELECT NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
CT Biopsy Storyboard : Registration
Need a progress bar during
registration, then report RMS error after registration
©2005 Surgical Planning Laboratory, ARR Slide 26
LOAD SELECT NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
CT Biopsy Storyboard: Selection Idea #1
Show original slices in here
SELECT SLICE 1/2/3/4
S
croll bar
©2005 Surgical Planning Laboratory, ARR Slide 27
LOAD SELECT NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
CT Biopsy Storyboard: Selection Idea #2
Show original slices in
here
Drag/Drop into here
S
croll bar
©2005 Surgical Planning Laboratory, ARR Slide 28
LOAD SELECT NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
CT Biopsy Storyboard: 2D Navigation
Slice #1
Slice #3
Slice #2
Slice #4
Show the needle trajectory on top of each slice
©2005 Surgical Planning Laboratory, ARR Slide 29
CT Biopsy Phase 5: Implement and Test
1. Create scans with/without fiducials (to test registration algorithms)
2. Build phantoms to measure navigation accuracy
3. Power cycle computer to test system robustness
• Unplug/plug tracking system, etc.
©2005 Surgical Planning Laboratory, ARR Slide 30
CT Biopsy Phase 6: Next Iteration
Next round, we may need to:
• Calibrate the biopsy needle intraoperatively
• Navigate the biopsy needle
• Use needle-oriented reslicing
• Migrate system to use MRI scans (new application: software re-use)
• Control MRI scanner for in-scanner biopsy (new application: software re-use)
©2005 Surgical Planning Laboratory, ARR Slide 31
Example Application:
Ventriculoscopy for Brain Tumor Biopsy
©2005 Surgical Planning Laboratory, ARR Slide 32
Clinical Problem: Deep Brain Biopsy
Idea:
• Use flexible scope to biopsy from within a brain ventricle
Technique:
• Same setup as for CT biopsy navigation
• Show 3D location of scope inside volumetric image
• Needs calibration of optical image to tracking device
©2005 Surgical Planning Laboratory, ARR Slide 33
Deep-Biopsy Phase 1: Procedure Workflow
1. Prepare patient (including fiducials)
2. Transfer patient to CT or MRI scanner
3. Acquire the 3D scan (inject & image)
4. Load scan into Navigator
5. Software calculates registration
6. Calibrate ventriculoscope
7. Software displays scope in volumetric scan
8. Perform the biopsy
9. Close the patient
©2005 Surgical Planning Laboratory, ARR Slide 34
Deep-Biopsy Phase 2: Software Actions
1. Load instrument descriptions
2. Load volumetric (MRI/PET/CET) scan
3. Detect fiducials
4. Calculate registration
5. Calibrate ventriculoscope to tracker device
6. Confirm calibration using a sharp probe
7. Track the ventriculoscope
8. Show scope in volumetric (MRI/PET/CET) scan
©2005 Surgical Planning Laboratory, ARR Slide 35
Deep-Biopsy Phase 3: Procedure Steps
1. Screen to select scan from disk
2. Screen to give registration progess
3. Screen to calibrate ventriculoscope
4. Screen to verify calibration
5. Screen to display navigation
Additional Requirements:
– Forward/backward/exit buttons
– “Tabs” to other tasks label “forward”
©2005 Surgical Planning Laboratory, ARR Slide 36
LOAD CALIBRATE VERIFY NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
Deep-Biopsy Storyboard: File Selection
All we need here is a simple dialog box
ACCEPT
©2005 Surgical Planning Laboratory, ARR Slide 37
LOAD CALIBRATE VERIFY NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
Deep-Biopsy Storyboard: Registration
Need a progress bar during registration, then report RMS
error after registrationACCEPT
©2005 Surgical Planning Laboratory, ARR Slide 38
LOAD CALIBRATE VERIFY NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
Deep-Biopsy Storyboard: Calibrate Vscope
Show live video feed in here
CALIBRATE
©2005 Surgical Planning Laboratory, ARR Slide 39
LOAD CALIBRATE VERIFY NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
Deep-Biopsy Storyboard: Verification
3D probe model on top of live video feed here
ACCEPT
©2005 Surgical Planning Laboratory, ARR Slide 40
LOAD CALIBRATE VERIFY NAVIGATEREGISTER
LOGO GOES HERE EXIT
Tool Status Display
Deep-Biopsy Storyboard: 3D Navigation
Live video feed from scope
Scope field-of-view cone inside
volume
Forward rendering from
scope
©2005 Surgical Planning Laboratory, ARR Slide 41
Deep-Biopsy Phase 5: Implement and Test
1. Create scans with/without fiducials (to test registration algorithms)
2. Calibrate optics to tracker device
3. Verify calibration with sharp probe
4. Build phantoms to measure navigation accuracy
5. Power cycle computer to test system robustness
• Unplug/plug tracking system, etc.
©2005 Surgical Planning Laboratory, ARR Slide 42
Deep-Biopsy Phase 6: Next Iteration
Next round, we may need to:
• Calibrate the biopsy needle
• Navigate the biopsy needle
• Use needle-oriented reslicing
• Acquire/integrate intraoperative MRI (new application: software re-use)
• Migrate to laparoscopic ultrasound (new application: software re-use)