th WORKSHOP ON TRANSFORMER MUMBAI - INDIAtrafocare.org/workshop/pdf/Trafocare_Mumbai_2018.pdf ·...

20
August 7‐8, 2018 Tuesday & Wednesday MUMBAI - INDIA Note Keep it Tight Keep it Clean Keep it Cool Swachh Trafo Abhiyan Mission – Conservation of Transformers th 6  WORKSHOP ON TRANSFORMER Distribution & Power Transformer In Association With Organized by : Cluster Knowledge Mob : +91 9867976570, Email : [email protected] www.trafocare.org Platinum Sponsor Laxmi Associates Gold Sponsors American R Silver Sponsors NSM TECHNOLOGIES PVT. LTD. Simply Measure... Utility / Industry Tx issues Asset Life Cycle Management System RLA – Residual Life Assessment Best O&M Practices Fire & Safety of Transformers Selection Guide for Dry type Vs Mineral oil Vs Ester oil Think Thermally – Thermal Imaging Global Monitoring of Power Transformers Advantages & Challenges A Tutorial on DGA & Case studies PD Monitoring Case Studies Maintenance Strategies for On‐Load Tap Changers Fish Solar Farm Leak xpert

Transcript of th WORKSHOP ON TRANSFORMER MUMBAI - INDIAtrafocare.org/workshop/pdf/Trafocare_Mumbai_2018.pdf ·...

August 7‐8, 2018Tuesday & Wednesday

MUMBAI - INDIA

Note

Keep it TightKeep it CleanKeep it Cool

Swachh Trafo Abhiyan

Mission – Conservation of Transformers

th6  WORKSHOP ON TRANSFORMER

Distribution & Power

Transformer

In Association With

Organized by : ClusterKnowledge

Mob : +91 9867976570, Email : [email protected] www.trafocare.org

Platinum Sponsor

Laxmi Associates

Gold Sponsors

AmericanR

Silver Sponsors

NSM TECHNOLOGIES PVT. LTD.

S i m p l y M e a s u r e . . .

Utility / Industry Tx issues

Asset Life Cycle Management System

RLA – Residual Life Assessment

Best O&M Practices

Fire & Safety of Transformers

Selection Guide for Dry type Vs

Mineral oil Vs Ester oil

Think Thermally – Thermal Imaging

Global Monitoring of Power

Transformers Advantages &

Challenges

A Tutorial on DGA & Case studies

PD Monitoring Case Studies

Maintenance Strategies for On‐Load

Tap Changers

Fish Solar Farm

Leakxpert

Registration Fee:INR 15,000* or USD 300 Only + GST 18% Extra.

*Government Discount ‐ 20%To allow employees of Central & State Governments / PSU, to take advantage of the unique learning opportunities offered by these workshops, we offer a 20% discount off of the regular workshop rate. Government discounts cannot be combined with any other discount.

Group DiscountGroup of 5 in Rs. 50,000/‐ plus Service TaxGroup of 12 in Rs. 1,00,000/‐ plus Service Tax

Registration Fee will cover only: Participation in the event Tutorial Material Refreshments & Lunch

Event VenueEvent will be held in Mumbai. Venue address will be intimated to registered candidates two weeks before event date.

Registration How To Register

We will get in touch with you to complete the formalities.

Bank Details – Knowledge Cluster Pvt Ltd, ICICI Bank, Thane Branch, 400 602, A/C No – 003505012280IFSC Code – ICIC0000035

GSTIN ‐ 27AAECK7131P1Z3PAN No ‐ AAECK7131P

Cheque/DD in the name of “Knowledge Cluster Pvt Ltd, Thane” payable at Thane.

Please send email to [email protected]

Company Name___________________________

Number of Delegates_______________________

List of Delegates with following info

Name___________________________________

Designation______________________________

Company Name___________________________

Address_________________________________

Email id__________________________________

Mobile No________________________________

We are in the process of requesting – speakers for O&M of power & distribution transformer from various utilities & Industries. After receipt of their confirmations, names will be updated on website and communicated by email.

Theme based panel discussion by experts

Mission – Conservation of Transformers

2

In Association With

Jagdish Sandhanshiv+91 [email protected]

KNOWLEDGE CLUSTER PVT LTDFB ‐ 31, First Floor, Highland, Corporate Centre, Kapurbawadi, Thane West, India 400 607. Mo.: +91 22 4127 6570

Contact

www.trafocare.org

About OrganizersTrafo Mumbai is organized by Knowledge careCluster Pvt Ltd in association with IEEE, Independent Expert speakers, Altanova, SMSytems, Cargill, Easun MR Etc. We also invite expert speakers from the utility / industry to share their expertise in line with the theme of Trafocare. Over 400 power engineers have participated in earlier workshops. This mission survives on sponsorship and delegate fees. Team Trafocare is committed to work in the direction of our mission for conservations of transformers, swachh trafo abhiyan, Tx Fire & Safety and other topics that are important for the utilities, industries, OEMs and consumers.

Workshop on Transformer

August 7‐8, 2018, Tuesday & Wednesday MUMBAI - INDIA

Swachh Trafo Abhiyan

About CareTrafoTrafo is mission for conservation of careTransformers. Maintaining outside warranty transformers – hundreds & thousands of them – is a task of every utility & industry. Trafocare is an opportunity to see big picture of collective transformer fleet of dozens of utilities/industries and an attempt to sensitize towards the mission. Case study, Experience sharing, discussions and debates on real life transformer issues ‐ clarify doubts and gets exposed to knowledge outside the organization.

Trafo objective is that the known knowledge Careis discussed and that should help the end users ‐ To maintain their outside warranty transformers ‐To maintain their new transformers‐To decide on specs of buying new transformers

Since 2014 five workshops are conducted in Mumbai, Delhi, Hyderabad and Kolkata.

Why General workshop?Organizing such workshop in‐house exclusively for individual organization is not practically possible. However general workshop at common place gives time saving, cost sharing & Knowledge sharing advantage. Trafo is a unique niche carep l a t f o r m w h i c h e n c o u r a g e s discussions/interactions “Gyansabha” (avoids one way communication.) For quality of discussion during the workshop and quality engagement, we limit number of delegates and arrange them in comfortable round table cluster seating.

4 Continued on Page 4

About Speaker

Shri Virendra Kumar Lakhiani with over 48 years of experience has served reputed OEMs like BHEL, Crompton Greaves, Vijai Electricals & T&R, leading their design and development up to 1200KV transformers in India. To name a few, he was involved in development/technology transfer projects like ABB technology for 400KV shunt reactors at BHEL, developing 650KV shunt reactor, 800KV class power transformers, CTs, CVTs & Bushings, implementation of of PLM system, development of 3D Models in Siemens (Nx5) software, development of a state‐of‐art 765 kV UHV shielded laboratory at Mandideep, absorption and implementation of Toshiba 765 kV Technology and integration of Pauwel’s Technology. He was invo lved in establishment of latest technologies of 765 kV class transformers from ZTR Ukraine &

765 kV shunt reactors from Fuji japan at T&R. And at Vijay Electricals Hyderabad he was involved in successful development of 1200 kV ,333 MVA Auto Transformer for 1200 kV Bina Testing station of PGCIL.

He has also contributed towards a large green transformer, 75 MVA 132 kV class ,tested first time in India with Natural Esters and with a very low noise level of less than 55 dBA. He was convenor for recently published IS 1180 (Part 1): 2014 on distribution transformer and IS 1180 (Part 2) on ester filled Distribution transformers.

He has been long associated with CEA, CBIP, BIS and IEEMA standardization activities up to 1200 kV. He played active role in finalizing standard specifications

and parameters of 400 kV, 800 kV and 1200 kV Transformers in the country and upgrading CBIP Manual on Transformers. He has contributed more than 50 technical papers in national/international seminars and 3 of his papers fetched best paper awards. He chaired several sessions in d i f f e r e n t c o n f e r e n c e s . Va r i o u s professional institutions, engineering colleges, universities etc. were benefited with his lectures, R&D deliverables and technical papers.

He was Chairman of Trafotech Technical Committee 2006. He is an independent practicing consultant.

Mr. Virendra Kumar Lakhiani, India

TOPICS

Utility / Industry Tx issues

Asset Life Cycle Management System

RLA – Residual Life Assessment

Best O&M Practices

Fire & Safety of Transformers

Selection Guide for Dry type Vs Mineral

oil Vs Ester oil

Think Thermally – Thermal Imaging

Global Monitoring of Power

Transformers Advantages & Challenges

A Tutorial on DGA & Case studies

PD Monitoring Case Studies

Maintenance Strategies for On‐Load

Tap Changers

Fish Solar Farm

Discussion on Utility / Industry Tx issues

WHY DGA ?

BASICS OF DGA

DGA AND FAULT ANALYSIS

DGA INTERPRETATION – EXPERT SYSTEMS

IEC 60599 INTERPRETATION OF DGA

IEEE C57.104 INTERPRETATION OF DGA

CIGRE TASK FORCE INTERPRETATION OF DGA

DGA METHODOLOGY

DGA EXAMPLES – CASE STUDIES

DGA – HEAT RUN TEST

DGA – TAKE AWAY

IMPROVED DGA DIAGNOSIS CRITERIA

RESIDUAL LIFE ASSESSMENT (RLA)

Dissolved Gas Analysis(DGA) – the most commonly used condition

monitoring tools

A tutorial on DGA by Shri Virendra Kumar Lakhiani

Photo of “Trafo Kolkata Team”care

• Furans‐ Chemical structure and causes• Analysis of Furanic compound by ASTM Method D 5837 or IEC Method 61198• Factors influencing the concentration and stability of Furanic compounds• Basic theory of Degree of Polymerization (DP) and measurements• Correlation between DP and Furan• Understanding the Xue Chendong equation and its limitations• End of life criteria for DP

Transformer Fire & SafetyFire incidences in power & distribution transformers are not uncommon. However, recently in the rarest of rare transformer fire accident 21 people died. Hence through the mission for Transformer Fire & Safety, we would

like to sensitize all the individuals/stakeholders to work in the direction of ‘zero transformer fire accidents and safety to personnel around it’.

Distribution Transformers are installed in the public premises. Such property is subjected to different kind of abuse by public too. The reason for transformer fire are not only technical (OEM or O&M) but are contributed directly/indirectly by the consumers and other elements in society too.

Our aim is this topic is discussed – corrective & preventive actions by other utilities/industries are shared. Already implemented solutions/case studies are shared and “Latest problem statements” are defined. This can be an exercise where additional field study is required. During this discussion process ‐ “problem solving approach” shall be discussed and we make progress in the direction to minimize the issue of Transformer Fire and Safety.

We are also trying to request and invite authorities from CEA & Fire department for experience sharing, discussion and guidance.

5 Continued on Page 6

Maintenance StrategyComponents of risk‐based maintenance strategies‐ Condition‐based maintenance & C o n t i n u o u s O n ‐ L i n e M o n i t o r i n g ( P D, Thermography, DGA, Vibration, Noise)

Risk‐based asset life cycle management strategies ‐ Condition assessment, Transformer RLA, Health Index,refurbishment, l ife extension and replacements

Development of asset life cycle management system for transformers• Transformer asset information management• Development of processes, methods and application of technologies• Impact of failure, risk calculation models and methodology• Developing transformer asset management strategy & plans

Assessment of remaining life by Residual Life Assessment (RLA) studies.• Paper aging and its effect• Solid Insulation and Cellulose degradation

Mr. Stephan HebererItaly

Stephan Heberer holds a degree (Dipl. Ing. FH) in mechanical engineering with a focus on power generation from the University for Applied Sciences in Nurnberg.He started his career in 1993 working for ABB, where he held various management positions in MV and HV switchgear as well as distribution and power transformer.Since 2008, he is active in the field of condition monitoring for electrical apparatus with a main focus on partial d ischarge. Working for d i fferent companies in Zurich, Glasgow, Manchester and lastly in Bologna, he has been involved in various projects around the world for condition monitoring of generators, switchgear, transformer and cables for different industries like power generation, transmission and distribution, offshore windfarms and Oil&Gas.

Mr. Stephan HebererItaly

About Speaker

“Global Monitoring of Power Transformers ‐ Advantages & Challenges “

By Mr. Stephan Heberer, Italy

A presentation on ‐Asset Life Cycle Management System

RLA – Residual Life AssessmentPD Monitoring Case Studies

By Dr. Aradhana Ray

Reliable but safe transformersRight sizing of transformers.Minimizing the Risk of Transformer FiresEnhanced Maintenance PracticesOperating PracticesElectrical ProtectionLess‐Flammable Insulating Media Dry Type TransformersGas Insulated Transformers

Less Flammable Insulating FluidsProperties of Less‐Flammable FluidsHigh Molecular Weight HydrocarbonEstersCombustion Characteristics and Test ResultsTank Design as Protective StrategyPressure Reducing TechniquesGas Cushion TransformersVerification of Pressure Withstand CapabilityChoice of Components as Protective StrategiesBushingsCable Terminations and Cable BoxesInsulating Liquid Filled Cable BoxesAir Insulated Cable BoxesSF6 ConnectionConservator Shut‐off Valve

Transformer Failure mechanism & FMEA (Failure Mode Effect Analysis)• High operating temperature• System faults• Careless or negligent operation, Leakage• OLTC failure and Poor Maintenace• Increased water content• Heating problems due to accumulated sludge deposits on windings and in cooling ducts.• Hot connections• Pump or fan failure including bearings• Bushing failure• Winding failure

Utility / Industry Transformer issuesRespected engineers from utilities and industries are requested to send transformer related issues to team trafocare; We will do our best to cover it in respective speakers’ topics. Also before and after the workshop, we will continue to work on the respective threads of issues. Gyansabha is the best opportunity to discuss one problem from all angles of OEM, End user, Field expert, Lab Expert, Transformer component experts etc. Every problem may not have a quick solution that works for all. Some of the issue may need more involved work, field study n research, involvement of more parties which do not fit in regular course of business. Trafocare is committed to work in the direction of our mission for conservations of transformers, swachh trafo abhiyan, Tx Fire & Safety and other issues feaced by the utilities, industries, OEMs and consumers.

Note: W e a r e e x p e c t i n g i n p u t s f r o m t h e utilities/industries for topics of their choice, accordingly expert speakers will change their presentations in the large interest of the audience. We encourage more real life questions & discussions, you are most welcome to submit your points of interests, questions to tune the presentations accordingly.

6

Continued from page 5

Mr. Rajaram Shinde, has over 25 years of experience in Transformers with diverse b a c k g r o u n d a n d q u a l i t i e s l i k e transformational leader & Technologist. He is on Cargill board as Global Technology Adviser/Director Dielectric Fluids for Cargill’s Industrial Specialties business unit. Being member of various national & i n te r n a t i o n a l fo r u m /c o m m i tte e s IEC/IEEE/BIS has invented three products & secured patents. Rajaram is Executive MBA & PGD in statistical process control, also possess certificate as assessor of business excellence model. He is graduated in Electrical Engineering from Pune University & now supporting technology spread globally on usage of fire safe, go‐green dielectric fluid with improved performance.

Mr. Rajaram Shinde

About Speaker

Mr. Rajaram Shinde

Howcanweavoidfireintransformers?

HowtominimizeriskoflossofHumanlife?

Whatisemergencyresponsesysteminthe

eventoftransformerfire?

HowtocontrolTransformerFireand

Damage?

Invitation to Speakers

Presentation on ‐ Selection Guide for Dry type Vs Mineral oil Vs Ester oil By Sh Rajaram Shinde

A presentation on ‐ Maintenance Strategies for On‐Load Tap Changers by Mr Shrikant Potnis

Mr. Shrikant PotnisCEO

Easun MR Tapchangers

Mr Shrikant Potnis is engineering graduate from Walchand College of Engineering in 1976 and post graduation from I.I.T. Mumbai ‐in Ind. Design‐ in 1978. He started his career with Transformer Division of Crompton Greaves in 1978 and worked for 33 years in various different divisions of CGL. He worked for more than 10 years with m/s Crompton Greaves Ltd as R & D Head of Switchgear Division ‐ Nasik. He has presented more than 20 papers on various topics in conferences like Swicon, Switrend, IET, MSETCL, PGCIL , CPRI, IEEMA etc. Currently he is working as CEO for more than 5 years with “ M/S Easun MR Tap Changers Pvt Ltd “ ‐ A German JV Company manufacturing On Load Tap Changers for Transformers up to 765 kV. He has travelled extensively for attending conferences, testing of various products, Technology Transfers, establishing JV companies, customer visits etc. He is having, to his credit 11 patents in various Switchgear/Tap Changer products. He has worked as a member of BIS committee on Circuit Breakers, Cigre working group ET08 India chapter.

Mr. Shrikant Potnis

About Speaker

Leakxpert

LeakExpertteamhassuccessfullyattendedactiveoilleaks

of220KV163MVAGeneratingTransformer220nos.ofBell

TankBolts&itsGasket,usingPowerpatchmanufacturedby

AmericanPolywaterCorporationUSA.

Bhagyodaya Sales & Services, +91 9604916916, 9890160315. E: [email protected] www.leakxpert.com

www.leakxpert.com

Swachh Trafo AbhiyanFrom our past experience of workshops, we

realized small problems like transformer

gaskets/oil leakages are not even considered as

technical problems by industry. And utilities/fleet

owners are helpless with fleet of thousands of

transformers and it is practically not possible to

take outage and replace all the gaskets. This has

triggered sensitising on this small but significant

issue and we started “Swachh Trafo Abhiyan”.

Mission – Swachh Trafo Abhiyan Forming Cluster of utilities and industries for

experience sharing on this issue. Sensitising leakage is not just loss of oil but door

for moisture ingress, fire, environment issue. Auditing for Housekeeping & Keep it Tight. Keep

it Clean. Keep it Cool. Existing transformers leaks should be arrested by

right material & methods. Can we design and manufacture new

transformers for our next generation that won’t

leak during its lifetime?

We are sure that cluster of utilities and industries

participating in this mission shall do the

experience sharing on specifications, vendor

qualifications, Design review, QAP, Inspections,

transportation etc.

‘Moisture is enemy of

Trafo & Oil leakage

is the door for it’

Clean Trafo Movement

Swachh Trafo Abhiyan Copyright 2017 Knowledge ClusterC

www.trafocare.org

Visual 1 of 3

Please send us email to participate and subscribe updates on this topic.

[email protected]

“Great! I wish you luck for taking this much needed initiative. I trust constantly weeping transformers like Meena Kumari in Mother India will be a thing of the past!!”

Trafo Oil is arc Quenching Medium inside

Trafo Tank, and the same oil is fuel to fire...

oFire hazard = Oil + Oxygen + >135 C (Fire Point)

Oil Leakage expose it to Oxygen....

Copyright 2017 Knowledge ClusterC

www.trafocare.orgSwachh Trafo Abhiyan

Visual 2 of 3

FIRE

FIR

E

Swachh Trafo Abhiyan Copyright 2017 Knowledge ClusterC

www.trafocare.org

AlarmOil Level

Low

ActionTop - Up Oil

Where is

Missing

Oil ?

Visual 3 of 3

9

“Appeal”A u t o m o b i l e i n d u s t r y c a n

manufacture an engine that does

not leak at high pressure, high

temp, heavy impacts & vibrations.

Can India produce power and

distribution transformers for our

next generation that won’t leak for

life time?

Swachh Trafo Abhiyan

“Inspired from Swachh Trafo Abhiyan, we have started similar exercise in our O&M of assets”

Mr Sanjay MishraChairman, SM Group

Laxmi Associates

Corporate Office: 13, 14, 15 ‘Sun Enclave’ Near Sun City Paradise, Manjalpur, Vadodara, Gujarat – 390016

Mobile No: +91-9374076950, 9376446910

E-mail: [email protected] • Website: www.laxmiassociates.in

Laxmi Associates

GIS PD Testing

Mission – Conservation of Transformers

The Park, Delhi.

The Park, Hyderabad.

The Imperial, Vashi.

Swachh Trafo Abhiyan

Workshop on Transformer

August 7‐8, 2018Tuesday & Wednesday

MUMBAI - INDIA

Photo of “Trafo Kolkata Team”care

ISA ADVANCE INSTRUMENTS (I) Pvt. Ltd.C-33, Ground Floor, Sector-2, NOIDA-201301,Uttar Pradesh, INDIAPhone: +91-120-4543853/54/4222712Fax: +91-120-45474772Email: [email protected]

STS5000 & TD 5000 Multi-Function Test Kit for Instrument and Power Transformer

Variable output frequency: 5‐500Hz

Capacitance and Tan Delta Measurement up to 12KV

Primary injection testing capabilities up to 800A orup to 3000 A, with the optional module BUX 3000

·DTCoffersyouOEMindependentcounselingservices·DTCoffersyoucounselingservices,resultopen,not

pre-determinedsolutionoriented.

·DTCoffersyoucounselingserviceswithaspecialview

toachievingcustomerexpectations

DTC (Daemisch-Transformer-Consult) is specialized in providing consulting services

for the power transformer sector. In our capacity as consulting company and pioneer

in all aspects of transformer life time cycle assessment, we offer the following range

of services:

·DTCputsthewholeofitsexperienceatyourservice

·DTCsharesdecadesofknow-how

·DTCactsasyourtechnical"advocate"

·DTCisestablishedinternational

DTC – Daemisch Transformer Consult Dipl. Ing. Georg Daemisch, M.Sc. (EE) Alte Nürnberger Straße 32 a D-93059 Regensburg

Tel: +49 (0) 941 87867 Fax: +49 (0) 941 87845 Mobile +49 (0) 172 8909973

www.transformer-consulting.com Email: [email protected]

GMBHTRANSFORMER LIFE MANAGEMENT SYSTEMS

Er. Georg P. Daemisch

Regensburg‐Germany

WorkshoponUndergroundCablesCare4Cable

November, 2018Mumbai - India

KnowledgePartner Speakers CaseStudies Sponsorship Nominations

TOPICSVLFtesting&DiagnosticTech

Subjectexpertswithcasestudies

CableFaultLocation

DTS-DistributedTempSensing

PartialDischargeMeasurement

CableTerminationsHVcasestudies

Innovations

MarketResearch

Utilityexperiences

LifeCycleManagement

WE ARE LOOKING FOR

Jagdish Sandhanshiv

+91 9867976570

[email protected]

Pull-Planner™ 4.0

Heavy Duty Cable Lubricant

Key Features• Dyna‐Blue® Reduces coeffitient of friction between cable Jacket & Surface of the cable : Increase Cable Life• Clean ‐ Easy To Use• Stays Slippery ‐ Won’t Dry Out

Cable Pulling SoftwareThe software calculates cable pulling tension and sidewall pressure around bends using the pulling equations. The software also utilizes industry standards to calculate maximum pulling tension and conduit fill. Tension estimates are useful in designing conduit systems and planning cable pulls. Such planning can save time and money by minimizing splices, vaults, pulling set-ups, etc., while ensuring installation tensions that won’t damage cable. Cables are susceptible to damage when sidewall bearing pressure limits are exceeded, making preplanning extremely important. The program runs on English or metric units.

• Low Cost• Temperature Stable ‐ No Waste• Safe To Use With Most Cables

www.polywater.com

Contact: [email protected]

WorkshoponSolarAssetManagementCare4Solar

2019Mumbai - India BestO&M

Practices

AssetManagement

Clean&GreenSolarMission

KnowledgePartner Speakers CaseStudies Sponsorship Nominations

WE ARE LOOKING FOR

Jagdish Sandhanshiv

+91 9867976570

[email protected]

NicheCustomerengagementplatform

FourNationalLevelworkshops

Blogs,casestudies,videos&DM

Utilityexperiences

LifeCycleManagement

Subjectexpertswithcasestudies

TrainingCourses

MarketResearchonO&M

Innovations

Solaxpert

Key Features• Enhances Efficiency : Increase Solar Panel efficiency by 3 to 5%• Effective Cleaner: Cleans a wide range of organic and inorganic contaminants• Biodegradable : Does not harm plant/animal life and water table• Phosphate & Chlorine Free: Environmentally friendly.• pH neutral - non-caustic - non-alkaline-non solvent: Does not affect metal rails, mastik or anti-reflective coatings.• No deionized water rinse: Spot-free finish at reduced costs• Water Shedding formulation: Reduces water spotting and cleaning frequency.

www.solaxpert.com

Mr. Charles ColeVice President‐International Division

American Polywater Corporation

Mr. Charles ColeVice President‐International DivisionAmerican Polywater Corporation

About Speaker

Charles Cole, Vice President‐International Division, American Polywater Corporation, has over 30 years of experience providing innovative and effective repair and maintenance solutions to the electrical and communications industries. Amongst them are leak repair and protection systems for transformer and switch gear. Used worldwide, these products stop active oil and SF‐6 leaks to prevent equipment damage and minimize degradation of equipment components.

SIX DECADES IN MEASURING INSTRUMENTSMETREL is one of the world leading manufacturers and suppliers of high quality electrical measurement and test instruments & is a recognised expert in the measurement and testing industry through the design a n d m a n u f a c t u r e o f advanced and innovative test and measurement solutions.

Measuring and Regulation Equipment Manufacturer

e: [email protected] w: www.nsmtechnologies.co.in Skype: nitin.barve1974

Off.: ‘BIZSOL HOUSE’, 2‐A, Second Floor, Plot No. 22, Near Vascon IT Park, Indira Nagar, Wadala Road, Nashik ‐ 422 006.Mo.: +91 9130009410

NSM TECHNOLOGIES PVT. LTD.

S i m p l y M e a s u r e . . .

National Channel Partner

Pylon/Tower Footing Resistance

HV Insulation Testers

Digital Multi meter / Clamp meter

Machines ‐ PAT Testers/ Appliances ‐ CE Multi Tester

Earth Testers Photovoltaic Installation Testers

Contact Resistance / Micro Ohm Meters

Power Quality Analyser (Class‐A & S)

Turn Ratio/Winding

Resistance

“ “

“ “

“ “

www.easunmr.com/nifpss

Dr. Aradhana RayTechnical Director Laxmi Associates

Dr. Aradhana Ray Ph. D. in Electrical Engineering with 23 years’ experience with Doble Engineering USA, Omicron Energy Services, Austria & in Short Circuit Test Laboratory ERDA, Vadodara. She has done consulting, third party inspection and Asset management projects, specification & maintenance manual (third party) documentation related to EHV class power equipment in several countries such as India, Malaysia, Dubai, OMAN, North America, South Africa and Australia. She has conducted many Workshops worldwide over past 9 years. Some 4,000 managers, engineers have attended her training courses and workshops.She has written more than 45 national and international publications. She was a recipient of "Dr Vikram Sharabhai Young Scientist Award" in 2005. She has also served on technical committees of national and international conferences including IEC, IEEMA, CBIP,TIFAC, BIS, CIRED Malaysia Conferences and she is Principle member for Development of IEC‐ ETD 53 on Standardization of the management of assets in power networks.Currently she is working on implementation of Asset Management project based on PASS 55 Standards with various utiliites like Sarawak Energy Berhad (SEB), TNB & TAMAS Malaysia.

Dr. Aradhana Ray

About Speaker

Mr Imteyaz Siddqui RASM‐South Asia & GCC,

ALTANOVA Group

www.trafocare.org

August 7‐8, 2018Tuesday & Wednesday

Organized by

Knowledge Cluster

KNOWLEDGE CLUSTER PVT. LTD.

KCLUSTER

Contact Us:

Office Address :Unit No: FB 31, First Floor, Highland Corporate Center, Next to City Mall, Kapurbawadi, Thane (W) 400 607, Maharashtra, INDIA. Ph.: +91 22 4127 6570Web.: www.kcluster.com/workshop : www.trafocare.org www.facebook.com/knowledgecluster

ContactJagdish Sandhanshiv+91 9867976570 [email protected]

Mission – Conservation of Transformers

MUMBAI - INDIA

th6  WORKSHOP ON TRANSFORMER

Workshop on Transformer

In Association With