TFR experiment

download TFR experiment

of 25

Transcript of TFR experiment

  • 7/30/2019 TFR experiment

    1/25

    1

    TABLE OF CONTENTS

    CONTENTS PAGE

    Abstract/Summary 2

    Introduction 3

    Aims/Objectives 4

    Theory 5

    Apparatus 8

    Methodology/Procedure 9

    Results 13

    Calculations 15

    Discussion 22

    Conclusion 23

    Recommendations 24

    Reference 24

    Appendices 25

  • 7/30/2019 TFR experiment

    2/25

    2

    ABSTRACT

    There are 2 experiment that had to be done for tubular flow reactor (TFR). The first

    experiment was conducted to examine the effect of a pulse input in tubular flow reactor

    and to construct a residence time distribution (RTD) function for the tubular reactor.

    While the second objective for experiment 2 is to examine the effect of a step change

    input in tubular flow reactor and to construct a residence time distribution (RTD)

    function for the tubular flow reactor. From the graph of first experiment, it can be seen

    that the residence time distribution (RTD) for pulse input increased with time. However

    after a few minutes, it will slowly decreases until the value of zero. Besides that, for the

    second experiment, it can be seen that the value slowly increase of output conductivity

    and E(t) until it is constant. The mean residence time, second moment (Variance) and

    third moment (Skewness) were calculated was calculated from the graph. For the first

    experiment, the value of residence time is 0.151 min, the second moment (Variance) is

    0.0369 min2 and the third moment (Skewness) is 0.0129 min5/2. For the experiment 2,

    the mean residence time, the second moment (Variance) and third moment (Skewness)

    is 0.0998 min, 7.99 10 min2 and 3.197 10 min5/2 respectively.

  • 7/30/2019 TFR experiment

    3/25

    3

    INTRODUCTION

    A tubular reactoris a vessel through which flow is continuous, usually at steadystate, and

    configured so that conversion of the chemicals and other dependent variables are

    functions of position within the reactor rather than of time. In the ideal tubular reactor, the

    fluids flow as if they were solid plugs or pistons, and reaction time is the same for all

    flowing material at any given tube cross section. Tubular reactors resemble batch reactors

    in providing initially high driving forces, which diminish as the reactions progress down

    the tubes.

    Flow in tubular reactors can be laminar, as with viscous fluids in small-diameter tubes,

    and greatly deviate from ideal plug-flow behavior, orturbulent, as with gases. Turbulent

    flow generally is preferred to laminar flow, because mixing and heat transfer are

    improved. For slow reactions and especially in small laboratory and pilot-plant reactors,

    establishing turbulent flow can result in inconveniently long reactors or may require

    unacceptably high feed rates

    However, many tubular reactors that are used to carry out a reaction do not fully conform

    to this idealized flow concept. In an ideal plug flow reactor, a pulse of tracer injected at

    the inlet would not undergo any dispersion as it passed through the reactor and would

    appear as a pulse at the outlet. The degree of dispersion that occurs in a real reactor can be

    assessed by following the concentration of tracer versus time at the exit. This procedure is

    called the stimulus-response technique. The nature of the tracer peak gives an indication

    of the non-ideal that would be characteristic of the reactor. For most chemical reactions, it

    is impossible for the reaction to proceed to 100% completion. The rate of reaction

    decreases as the percent completion increases until the point where the system reaches

    http://en.wikipedia.org/wiki/Plug_flow_reactor_modelhttp://en.wikipedia.org/wiki/Steady_statehttp://en.wikipedia.org/wiki/Steady_statehttp://en.wikipedia.org/wiki/Steady_statehttp://en.wikipedia.org/wiki/Laminarhttp://en.wikipedia.org/wiki/Turbulenthttp://en.wikipedia.org/wiki/Turbulenthttp://en.wikipedia.org/wiki/Laminarhttp://en.wikipedia.org/wiki/Steady_statehttp://en.wikipedia.org/wiki/Plug_flow_reactor_model
  • 7/30/2019 TFR experiment

    4/25

    4

    dynamic equilibrium (no net reaction, or change in chemical species occurs).The

    equilibrium point for most systems is less than 100% complete. For this reason a

    separation process, such as distillation, often follows a chemical reactor in order to

    separate any remaining reagents or by products from the desired product. These reagents

    may sometimes be reused at the beginning of the process, such as in the Haber process.

    Tubular flow reactors are usually used for this application which are:

    1. Large scale reactions2. Fast reactions.3. Homogeneous or heterogeneous reactions4. Continuous production5. High temperature reactions

    OBJECTIVE

    Experiment 1:

    1. To examine the effect of a pulse input in tubular flow reactor.2. To construct a residence time distribution (RTD) function for thetubular reactor.

    Experiment 2:

    1. To examine the effect of a step change input in tubular flow reactor.2. To construct a residence time distribution (RTD) function for thetubular flow reactor.

    http://en.wikipedia.org/wiki/Distillationhttp://en.wikipedia.org/wiki/Haber_processhttp://en.wikipedia.org/wiki/Haber_processhttp://en.wikipedia.org/wiki/Haber_processhttp://en.wikipedia.org/wiki/Haber_processhttp://en.wikipedia.org/wiki/Distillation
  • 7/30/2019 TFR experiment

    5/25

    5

    THEORY

    The residence-time distribution (RTD) of a reactor is a characteristic of the mixing that

    occurs in the chemical reactor. The RTD is determined experimentally by injecting an

    inert chemical, molecule, or atom, called a tracer, into the reactor at some time t = 0 and

    then measuring the tracer concentration, C, in the effluent stream as a function of time.

    In addition to being a nonreactive species that is easily detectable, the tracer should

    have physical properties similar to those of the reacting mixture and be completely

    soluble in the mixture. It also should not adsorb on the walls or other surfaces in the

    reactor. The latter requirements are needed so that the tracers behavior will honestly

    reflect that of the material flowing through the reactor. Colored and radioactive

    materials along with inert gases are the most common types of tracers. The two most

    used methods of injection are pulse input and step change input.

    In a pulse input, an amount of tracers N0 is suddenly injected in one shot into the

    feedstream entering the reactor in a short time as possible. The outlet concentration is

    then measured as a function of time. The effluent concentration-time curve is referred to

    the as the C curve in RTD analysis. The injection of a tracer pulse for a single input and

    output system is analyzed which only flow carries the tracer material across system

    boundaries.

    = () =

    ()

    For pulse injection we defined;

    () = ()

  • 7/30/2019 TFR experiment

    6/25

    6

    = ()

    The quantity E(t) is called residence-time distribution function. It is the function that

    describes in a quantitative manner how much time different fluid elements have spent in

    the reactor. The quantity E(t)dt is the fraction of fluid exiting the reactor that has spent

    between time t and and t + dt inside the reactor.

    In Step Change input, the equation goes;

    () = (

    )(

    )

    We can now analyze a step change input in the tracer concentration for a system with a

    constant volumetric flow rate. Consider a constant rate of tracer addition to a feed that is

    initiated at time t = 0. Before this time no tracer was added to the feed. Stated

    symbolically, we have;

    () = {0, < 0(), 0

    The concentration of tracer in the feed to the reactor is kept at this level until the

    concentration in the effluent is indistinguishable from that in the feed; the test may then

    be discontinued. Take C0 outside from the integral sign, that is;

    () = ()

    [()

    ] = (

    )

    = ()

    () = [() ]To obtain RTD function E(t);

    () = [() ]

    As for mean residence time, it is shown that, in the absence of dispersion, and for

    constant volumetric flow (v=v0) no matter what RTD exists for a particular reactor, ideal

  • 7/30/2019 TFR experiment

    7/25

    7

    or nonideal, the nominal space time, , is equal to the mean residence time, tm.

    = ()

    () = ()

    We also usually compare RTDs by using their moments instead of trying to compare

    their entire distributions. For this, we used three moments. First is mean residence time.

    The second moment commonly used is taken about mean and is called the variance, or

    square of the standard deviation.

    = ( )() The magnitude of this moment is an indication of the spread of the distribution; the

    greater the value of this moment is, the greater a distributions spread will be.

    = 1 ( )()

    This moment measures the extent that a distribution is skewed in one direction or

    another in reference to the mean. It is called the skewness.

  • 7/30/2019 TFR experiment

    8/25

    8

    APPARATUS

    Tubular Flow Reactor SOLTEQ BP 101-B

  • 7/30/2019 TFR experiment

    9/25

    9

    PROCEDURE

    General Start-Up Procedures

    1. All valves were ensured initially closed except valve V7.2. 20 liter of salt solution was prepared. For example, sodium chloride, NaCl

    (0.025M).

    3. The feed tank B2 was filled with the NaCl solution.4. The power for the control panel was turned up.5. The water de-ionizer was connected to the laboratory water supply. Valve V3

    was opened and feed tank B1 was filled up with the de-ionized water. Valve

    V3 was closed.

    6. Valves V2 and V10 were opened. Pump P1 was switched on. P1 flowcontroller was adjusted to obtain a flow rate of approximately 700 ml/min at

    flow meter F1-01. The conductivity display was observed at low value then a

    valve V10 was closed and pump P1 was switched off.

    7. Valves V6 and V12 were opened. Pump P2 was switched on. P2 flowcontroller was adjusted to obtain a flow rate of approximately 700 ml/min at

    flow meter F1-02. A valve V12 was closed and pump P2 was switched off.

    8. The unit was ready for experiment.

  • 7/30/2019 TFR experiment

    10/25

    10

    General Shut-Down Procedures

    1. Both pump P1, P2 and P3 were switched off. Valves V2 and V6 wereclosed.

    2. The heaters were switched off.3. The cooling water was kept circulating through the reactor while the

    stirrer motor is running to allow the water jacket to cool down to room

    temperature.

    4. All liquid were drained from the unit by opening valves V1 and V16 if theequipment is not going to be used for long period of time. The feed tanks

    were rinsed with clean water.

    5. The power for the control panel was turned off.

  • 7/30/2019 TFR experiment

    11/25

    11

    Experiment 1: Pulse Input

    1. General start-up procedures are performed.2. Valve V9 is opened and pump P1 is switched on.3. Pump P1 flow controller is adjusted to give a constant flow rate of de-ionized

    water into reactor R1 at approximately 700 mL/min at Fl-01.

    4. The de-ionized water is allowed to continue flowing through the reactor untilthe inlet (Ql-01) and outlet (Ql-02) conductivity values are stable at low levels.

    Both conductivity values are recorded.

    5. Valve V5 is closed and pump P1 is switched off.6. Valve V11 is opened and pump P2 is switched on. The timer is started

    simultaneously.

    7. Pump P2 flow controller is adjusted to give a constant flow rate of salt solutioninto the reactor R1 at 700 mL/min at Fl-02.

    8. The salt solution is allowed to flow for 1 minute, then reset and restart the timer.This is the start time of the average pulse input.

    9. Valve V11 is closed and pump P2 is switched off. Then, valve V9 is quicklyopened and pump P1 is switched on.

    10.The de-ionized water flow rate is made sure to be maintained at 700 mL/minby adjusting P1 flow controller.

    11.Both the inlet (Ql-01) and outlet (Ql-02) conductivity values are recorded atregular intervals of 30 seconds.

    12.The recording of the conductivity values is continued until all readings are

  • 7/30/2019 TFR experiment

    12/25

    12

    almost constant and approach the stable low level values.

    Experiment 2 : Step Change Input

    1. Valve V9 is opened and pump P1 is switched on.2. Pump P1 flow controller is adjusted to give a constant flow rate of de-ionized

    water into the reactor R1 at approximately 700 mL/min at Fl-01.

    3. The de-ionized water is allowed to continue flowing through the reactor untilthe inlet (Ql-01) and outlet (Ql-02) conductivity values are stable at low levels.

    Both conductivity values are recorded.

    4. Valve V9 is closed and pump P1 is switched off.5. Valve V11 is opened and pump P2 is switched on. The timer is started

    simultaneously.

    6. Both the inlet (Ql-01) and outlet (Ql-02) conductivity values are recorded atregular intervals of 30 seconds.

    7. The recording of the conductivity values is continued until all readings arealmost constant.

    8. General shut-down procedures are performed

  • 7/30/2019 TFR experiment

    13/25

    13

    RESULTS

    Experiment 1: Pulse Input

    Time (min) Conductivity (ms/cm) E(t) min-1

    Input Output

    0 0.0 0.0 0.0

    0.5 0.0 1.4 0.651

    1.0 0.0 2.0 0.930

    1.5 0.0 0.7 0.326

    2.0 0.0 0.2 0.093

    2.5 0.0 0.0 0.0

    3.0 0.0 0.0 0.0

    3.5 0.0 0.0 0.0

    4.0 0.0 0.0 0.0

    4.5 0.0 0.0 0.0

  • 7/30/2019 TFR experiment

    14/25

    14

    Experiment 2: Step change input

    Time (min) Conductivity (ms/cm) E(t) min-1

    input output

    0.5 0.0 0.0 0.0

    1.0 2.0 0.0 0.0

    1.5 2.3 0.0 0.0

    2.0 2.4 0.9 0.212

    2.5 2.5 1.3 0.306

    3.0 2.3 1.5 0.353

    3.5 2.2 1.6 0.376

    4.0 2.1 1.6 0.376

    4.5 2.1 1.6 0.376

  • 7/30/2019 TFR experiment

    15/25

    15

    SAMPLE CALCULATION

    Experiment 1: Pulse Input

    () =

    = 0.5

    () = (

    0 + 1 . 4 + 2 . 0 + 0 . 7 + 0 . 2 + 0 + 0 + 0 + 0 + 0 ) ( 0 . 5 )

    ()=2.15

    Divide each value of C(t) with the integral to obtain a value E(t)

    () = ()

    ()

    () = 1.42.15

    () =0.651

  • 7/30/2019 TFR experiment

    16/25

    16

    -0.5

    0

    0.5

    1

    1.5

    2

    2.5

    0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5

    outpu

    tconductivity

    (ms/cm

    )

    time (min)

    output conductivity vs time

    -0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5

    E(t)(

    min-1)

    time (min)

    E(t) vs time

  • 7/30/2019 TFR experiment

    17/25

    17

    Mean residence time

    = . ()

    = ()

    = 0.5 0.6512.15

    = 0.151

    Second moment, Variance

    = ( ) () = ( ) ()

    = ( ) ()

    = (0.50.151) (0.651)2.15

    =0.0369

  • 7/30/2019 TFR experiment

    18/25

    18

    Third moment, Skewness

    =

    ( ) () =( ) ()

    = ( ) ()

    = (0.50.151) (0.651)2.15

    =0.0129

  • 7/30/2019 TFR experiment

    19/25

    19

    Experiment 2: Step change input

    () =

    = 0.5

    () = (

    0+0+0+0+0. 9+1. 3+1. 5+1. 6+1. 6 +1. 6 ) ( 0. 5)

    () = 4.25Divide each value of C(t) with the integral to obtain a value E(t)

    () = ()

    ()

    () = 0.94.25

    () =0.212

  • 7/30/2019 TFR experiment

    20/25

    20

    -0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    1.4

    1.6

    1.8

    0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5outputconductivity

    (ms/cm

    )

    Time (min)

    output conductivity vs time

    -0.05

    0

    0.05

    0.1

    0.15

    0.2

    0.25

    0.3

    0.35

    0.4

    0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5

    E(t)(min-1)

    Time (min)

    E(t) vs Time

  • 7/30/2019 TFR experiment

    21/25

    21

    Mean residence time

    = . ()

    = () = 2.0 0.2124.25

    = 0.0998

    Second moment, Variance

    = ( ) () = ( )

    ()

    = ( ) () = (0.50.0998) (0.212)4.25

    =7.99 10

    Third moment, Skewness

    = ( ) () =( ) ()

    = ( ) () = (0.50.0998) (0.212)4.25

    =3.197 10

  • 7/30/2019 TFR experiment

    22/25

    22

    DISCUSSION

    There are two 2 experiment that had to be done using turbular flow reactor (TFR). For

    the first experiment the objective are to examine the effect of a pulse input in tubular

    flow reactor and to construct a residence time distribution (RTD) function for the

    tubular reactor. While for the second experiment, the objective are to examine the effect

    of a step change input in tubular flow reactor and to construct a residence time

    distribution (RTD) function for the tubular flow reactor.

    From the theory, the residence time distribution (RTD) is a function to describe time of

    fluid inside the reactor. According to the graph of residence time distribution (RTD)

    function which is E(t) versus time that had been plotted, for the first experiment, it

    shows that the trend of RTD for pulse input increased with time. However after a few

    minutes, it slowly decrease until the value become zero. Besides that, for the second

    experiment, the graph show an increase of RTD value until the value of output

    conductivity and E(t) is constant.

    After the graph was plotted, the mean residence time, second moment (Variance) and

    third moment (Skewness) were calculated. For the first experiment, the value of mean

    residence time is 0.151 min, the second moment (Variance) is 0.0369 min2 and the third

    moment (Skewness) is 0.0129 min5/2. For the experiment 2, the mean residence time,

    the second moment (Variance) and third moment (Skewness) is 0.0998 min, 7.99 10 min2 and 3.197 10 min5/2 respectively.In this experiment, it can be seen that pulse input and step change in tubular reactor

    method has a few differences. For pulse input method, it can be seen the inlet tracer

    concentration is suddenly change from zero value to the large value and return it to zero

    after a short time. While for the step input change method the feed tracer is suddenly

  • 7/30/2019 TFR experiment

    23/25

    23

    changed from steady C0 to steady value at Ct after time reached to zero.

    CONCLUSION

    The first experiment was conducted to examine the effect of a pulse input in tubular

    flow reactor and to construct a residence time distribution (RTD) function for the

    tubular reactor. While the second objective for experiment 2 is to examine the effect of a

    step change input in tubular flow reactor and to construct a residence time distribution

    (RTD) function for the tubular flow reactor. From the graph of first experiment, it can

    be seen that the residence time distribution (RTD) for pulse input increased with time.

    However after a few minutes, it will slowly decreases until the value of zero. Besides

    that, for the second experiment, it can be seen that the value slowly increase of output

    conductivity and E(t) until it is constant. The mean residence time, second moment

    (Variance) and third moment (Skewness) were calculated was calculated from the graph.

    For the first experiment, the value of residence time is 0.151 min, the second moment

    (Variance) is 0.0369 min2 and the third moment (Skewness) is 0.0129 min5/2. For the

    experiment 2, the mean residence time, the second moment (Variance) and third

    moment (Skewness) is 0.0998 min, 7.99 10 min2 and 3.197 10 min5/2respectively.

  • 7/30/2019 TFR experiment

    24/25

    24

    RECOMMENDATION

    1. Make sure Tank 1 and Tank 2 are full with sodium chloride and deionisedwater respectively

    2. Ensure that there are no leakage at the valve. This is to prevent it fromeffecting the result of the experiment.

    3. Make sure that the valve is open or close according to the general start-upprocedure carefully.

    4. For both experiments, do more trial to get average of conductivity for bothinlet (Qi-01) and outlet (QI-02) conductivity values in order to get more

    accurate results.

    REFERENCES

    1. Levenspiel, O., Chemical Reaction Engineering(3rd edition). John Wiley &Sons, USA (1999).

    2. Douglas, J. M. Conceptual Design of Chemical Processes, McGraw-Hill: NewYork, 1988.

    3. http://solve.nitk.ac.in/dmdocuments/Chemical/theory_plugflow.pdf4. Fogler H.S., Elements of Chemical Reaction Engineering, 3rd Ed., Prentice

    Hall (USA), 1999

  • 7/30/2019 TFR experiment

    25/25

    25

    APPENDICES