Texas Molecular Capabilities
Transcript of Texas Molecular Capabilities
www.texasmolecular.com
TM Deer Park Services LP (Texas Molecular)
Underground Injection Capabilities
February , 2010
www.texasmolecular.com
Texas Molecular Underground Injection Capabilities
• Fact Sheet
• General Capabilities
• General Limitations and Restrictions
• Specific Capabilities and Comments
• More Information
www.texasmolecular.com
Texas Molecular Underground Injection CapabilitiesFact Sheet
• Deer Park Facility (TM Deer Park Services LP)» Over 60,000,000 gallons injected annually» 2 FRP wells to service pH 0-14 without neutralization» Permitted to inject hazardous waste by TCEQ Underground Injection Permits and EPA
“No Migration” exemption.» Permit capacity: approx. 236,000,000 gallons per year» Bulk storage: 1.5 million gallons, 3.4 million gallon permit » Permitted drum storage: 6792 drums » Accept Bulk Truck, Bulk Rail, and Containers» 24/7 Receiving » 24/7 Customer Service» 5 Unloading pads
www.texasmolecular.com
Texas Molecular Underground InjectionGeneral Capabilities
• Manage Problem Wastewaters» Clean Water Act
Solve discharge or treatment problems No discharges to waterways Saves cost of onsite treatment and Frac tanks
» Land Disposal Restrictions. Met by EPA “No Migration” exemption
» Wide waste code list (D, F, K, U, and P)» Special wastewaters
D001 high organic subcategory D003 reactive sulfides and cyanides D009 high subcategory pH 0 to 14 Pesticides Difficult to treat or discharge water
» Separate solids and phased organics prior to deepwell
Texas Molecular Underground InjectionGeneral Limitations and Restrictions
• No fuming acids
• No radioactive waste
• No infectious wastes
• No waters or wastes with headspace vapors above OSHA PEL
• Limitations on wastes that corrode fiberglass linings and pipe
• Limited waste temperatures above 120 F
• Water that cannot filter at 20:1 dilution or “Batch Press”
• No phased highly toxic organics
• Limitations on emulsions
• Limitations on high molecular weight soluble organics
• Limitations on very low flash point, high vapor pressure wastes
• Limitations on water with Calcium
www.texasmolecular.com
Texas Molecular Underground Injection Specific Capabilities and Comments
Capabilities• Acids (Hydrochloric, Sulfuric,
Phosphoric, Chromic, etc)
• Nitric Acid (separate system)
• Caustics and high pH
• Sulfides in Liquid (D003)
•Water with metals
•Water with organics at high levels
Comments
• No fuming acids. Acids at most concentrations
• No solids with Nitric Acid
• All concentrations
• Headspace limited to 4.7 ppm
• No regular limitations
•Organics must be soluble or miscible, no emulsions
www.texasmolecular.com
Texas Molecular Underground InjectionSpecific Capabilities and Comments, continued
Capabilities
•Water with phased organics
•Water with solids
• Incompatible waters
•Water with corrosive organics
• Caustic Sulfides
•Waters with constituents that cannot be discharged
Comments•Organics separated for Fuels
• Solids filtered in filter presses
•May be segregated in own tank, volume permitting
• Accepted to solubility in water or decanted.
• Headspace H2S<10 ppm.
• Routinely managed (no discharge to waterways)
www.texasmolecular.com
Texas Molecular Underground InjectionSpecific Capabilities and Comments
Capabilities
•Waters with constituents greater than “land ban” standards
Comments
• Routinely managed (Federal EPA “No Migration” exemption)
www.texasmolecular.com
Texas Molecular Underground InjectionAdditional Questions
• More Information available at www.texasmolecular.com
• Contact Texas Molecular Account Manager
• Contact Texas Molecular Customer Service, 281-930-2540
www.texasmolecular.com