New Sound Level Measuring Instruments testo 815 / 816New Sound Level Measuring Instruments testo 815 / 816
testo 815/816Applications 815Applications 816Basic ConceptBasic ConceptMeasuring Tips
2/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
Application Areas testo 815Application Areas testo 815
testo 815
testo 815/816Applications 815Applications 816B i C t
Climate- and airconditioning i d t
Basic ConceptMeasuring Tips
industry
Use in trade enterprisesUse in trade enterprises
Measurements on office machineryMeasurements on office machinery
Measurement of machine noiseMeasurement of machine noise
Noise at combustion plants
3/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
p
A li ti A 816Application Areas 816
testo 816
testo 815/816Applications 815Applications 816B i C t
workplace measurements
Basic ConceptMeasuring Tips
industrial noise
environmental noise
classification measurements
neighbouring claims
4/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
Basic Concepts: Sound Evaluation GraphsBasic Concepts: Sound Evaluation Graphs
Pegel (dB)testo 815/816Applications 815Applications 816B i C t
The frequency range in which a sound level meter measures according to IEC 60651 ranges
Basic ConceptMeasuring Tips
Frequenz (Hz)
from31.5 Hz to 8000 Hz
The “ A” weighted graph corresponds to the hearing sensation of the human earof the human ear.
In this connection the technician speaks of “correct hearing volume”
The “C” weighted graph is used in case of many low
5/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
The C weighted graph is used, in case of many low frequencies within the acoustic signal.
Basic Concepts: Time Evaluation “Fast” or “Slow ”
1/8 s 1/8 s 1/8 s
Signal
1/8 s 1/8 s 1/8 s 1/8 s 1/8 s
Fast:
testo 815/816Applications 815Applications 816Basic Concept Fast:
Long-term recording of the readings 1/8 s (125ms) and the value calculated therefrom is shown on the display
Basic ConceptMeasuring Tips
Zeit / TimeSi l
therefrom is shown on the display.
1 sSignal
Slow:
Recording of the readings in 1 s (1000ms)
and the value calculated therefrom is shown on the display.
The acoustic signal can be weighted timely “Slow ” (1000ms) or “Fast” (125ms) in order to meet the requirements of the sound source
Zeit / Time
6/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
Fast (125ms), in order to meet the requirements of the sound source.
Basic Concepts: The Measuring Unit dB
Sound are tiny pressure variations of the ambient air.
Basic Concepts: The Measuring Unit dB
As the human ear holds an extremely large dynamic range, the specification of the pressure values would be unsuitable.
testo 815/816Applications 815Applications 816B i C t specification of the pressure values would be unsuitable.
Therefore a logarithmic presentation is preferred.
Basic ConceptMeasuring Tips
The derived parameter is a handy figure, the decibel = dB
The decibel is not an absolute measuring unit (as e. g. °C) but
a ratio. A measured value is put into ratio of a reference value (sound
Example:This equals how many dB?
reference value = 20 uPa).
meas. acoustic sound: 20.000 μPa Log10 (1000) = 3
20.000 μPa
20 μPa= 1000
7/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
reference pressure level: 20 μPa 20 x 3 = 60dB
Basic Concepts: Acoustic Pressure / Sound LevelBasic Concepts: Acoustic Pressure / Sound Level
testo 815/816Applications 815Applications 816B i C t
jet
Basic ConceptMeasuring Tips
truck
air hammer
office
library
forest
The “measuring range” (dynamic complexity) of the human ear ranges from 0 dB to approx 140 dB
hearing limit
from 0 dB to approx. 140 dB
In order to protect the health of mankind, ear protection has to be
8/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
used at a (permanent) sound level of >80 dB.
Basic Concepts: Accuracy Classes Standard DIN/IEC 60651Standard DIN/IEC 60651
testo 815/816Applications 815Applications 816B i C tBasic ConceptMeasuring Tips
The accuracy classes for sound level meter are internationally standardised in the standard DIN/IEC 60651
The operating temperature range is -10...+50°C. Instruments working in a range of 0...40 °C, receive a L as identification
Example: Class 2L
A sound level measuring instrument should be re-calibrated afterA sound level measuring instrument should be re-calibrated after translocation or temperature changes. For that purpose special sound calibrators are available
9/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
testo 815 and testo 816 = Class 2 (+/-1.0 dB)
Handling / Measuring Tipsg g p
testo 815/816Applications 815Applications 816B i C tBasic ConceptMeasuring Tips
microphone alignment distance to body
According to DIN/IEC standard a sound level meter has to bepositioned in a zero degrees angle towards the sound source. That is,the microphone points directly into the direction of the sound source.
In order to prevent interferences due to sound reflections on the body,the measuring instrument should be held at least 30cm away from the
10/2Testo AG, Präsentationstitel (Version), Ersteller, Datum, Vertraulichkeitsstufe
g ybody of the measuring person.
Thank youF d t il l tFor more details log on to -www.testo.in
www thermalimager co inwww.thermalimager.co.in
www.fluegasanalyser.co.in