HUMINATOR high precision humidity lab calibration validation training – individually programmable – easy to run menu – graphic display – RS-232 Interface industrial services temperature control 15°-40° C humidity range 5-95% RH

Transcript of Testo - Huminator

Page 1: Testo - Huminator

HUMINATORhigh precision humidity lab

calibration validation training

– individually

programmable

– easy to run menu

– graphic display

– RS-232 Interface

industrial services

temperature control

15°-40° C

humidity range

5-95% RH

Page 2: Testo - Huminator

HuminatorUsing the HUMINATOR you can quicklyand easily calibrate humidity measuringinstruments, probes and data loggersfrom Testo and other companies. TheHUMINATOR calibration system is a high-

performance, stand alone temperature/humidity reference generator. It features athermal servo system to stabilize tempe-rature in the range of 15 to 40°C. RelativeHumidity is rapidly generated in the range

of 5 to 95%.With the special Testo front panel of thechamber it is possible to calibrate 4 humi-dity probes at the same time. It is alsopossible to calibrate various data loggers.

I would like to order the items as indicated above:Please contact me at the address below:

name

company

date, signature

calibration validation trainingindustrial services

Your Testo-Partner:

Qty Discription Part no. Price Technical Data HUMINATOR

Recommended set for the HUMINATOR:HUMINATOR incl. Testo sensor and 15 probe adapters 0519.0801

testo 6502 channel reference temperature and humidity measuringinstrument with pressure measurement 0563.6501

Mains unit for testo 650 230 V/8 V/1 A 0554.1084

Highly accurate reference humidity/temperature probe+1%RH accuracy 0636.9741

Plug-in head cableto connect probe to measuring instrument 0430.0143

DKD calibration measuring points: 11,3, 30, 50, 75,3, 90%RH at +25°C 0520.0216

Case for HUMINATOR 0519.0820

Temperature range:................................................15 to 40°CHumidity range: ....................................................5 to 95%RHPower supply:................................85 to 264 VAC, 47 to 63 HzInterface: ........................................................................RS 232Display: ..............................................................Grafical displayDimension meas. chamber: ................ca. 147 mm diameter....................................................................probe depth 170 mm

Dimension: ..............................................................19 zoll rackAccuracy:..................................................Temperature 0,5°C

(10-85%RH at 25°C)Humidity 2%RH(10-85%RH at 25°C)

Stability: ............................................................................0,2°C(10-85%RH at 25°C)

..........................................................................................1% RH(10-85%RH at 25°C)

Supplement: ....................drying container with drying reagent