![Page 1: Test Report done by Lift Installer V12E€¦ · Maximum Earth Fault Loop Impedance (ZS) for circuit breakers with 0.4s disconnection time according to BS EN 60898 Nominal current](https://reader030.fdocuments.in/reader030/viewer/2022033120/5eb5c4670d5ca9625267beaf/html5/thumbnails/1.jpg)
Test Report done by
Lift Installer V12E ©KOLLMORGEN Steuerungstechnik Köln
Seite 1 von 5TB_Prüfprotokoll_0100T600_V12E.xls
![Page 2: Test Report done by Lift Installer V12E€¦ · Maximum Earth Fault Loop Impedance (ZS) for circuit breakers with 0.4s disconnection time according to BS EN 60898 Nominal current](https://reader030.fdocuments.in/reader030/viewer/2022033120/5eb5c4670d5ca9625267beaf/html5/thumbnails/2.jpg)
Test Report done by
Lift Installer V12E ©KOLLMORGEN Steuerungstechnik Köln
Seite 2 von 5TB_Prüfprotokoll_0100T600_V12E.xls
![Page 3: Test Report done by Lift Installer V12E€¦ · Maximum Earth Fault Loop Impedance (ZS) for circuit breakers with 0.4s disconnection time according to BS EN 60898 Nominal current](https://reader030.fdocuments.in/reader030/viewer/2022033120/5eb5c4670d5ca9625267beaf/html5/thumbnails/3.jpg)
Maximum Earth Fault Loop Impedance (ZS) for circuit breakers with disconnection time ≤ 5 s with U0 of 230V
Nominal circuit breakers [A] 2 4 6 10 16 20 25 32 35 40 50 63 A ZS = (Uo - U)/I-Last
Charakteristik B 7,67 4,6 2,87 2,3 1,84 1,44 1,15 0,92 0,73 0,57 0,46 0,37 Ω ZS(m) ≤ 2/3 x (Uo/Ia)
Charakteristik C 3,83 2,3 1,44 1,15 0,92 0,72 0,57 0,46 0,36 0,29 0,23 0,18 Ω
Test Report done by
Lift Installer V12E ©KOLLMORGEN Steuerungstechnik Köln
Seite 3 von 5TB_Prüfprotokoll_0100T600_V12E.xls
![Page 4: Test Report done by Lift Installer V12E€¦ · Maximum Earth Fault Loop Impedance (ZS) for circuit breakers with 0.4s disconnection time according to BS EN 60898 Nominal current](https://reader030.fdocuments.in/reader030/viewer/2022033120/5eb5c4670d5ca9625267beaf/html5/thumbnails/4.jpg)
Test Report done by
Lift Installer V12E ©KOLLMORGEN Steuerungstechnik Köln
Seite 4 von 5TB_Prüfprotokoll_0100T600_V12E.xls
![Page 5: Test Report done by Lift Installer V12E€¦ · Maximum Earth Fault Loop Impedance (ZS) for circuit breakers with 0.4s disconnection time according to BS EN 60898 Nominal current](https://reader030.fdocuments.in/reader030/viewer/2022033120/5eb5c4670d5ca9625267beaf/html5/thumbnails/5.jpg)
Test Report done by
Lift Installer V12E ©KOLLMORGEN Steuerungstechnik Köln
Seite 5 von 5TB_Prüfprotokoll_0100T600_V12E.xls