IEC 60086-5 Seguridad de las pilas con electrolito acuoso-dopdf.docx
TEST REPORT - Maxlifemaxlife.nz/uploads/1/7/9/2/17921577/intertek_test_report... · 2019. 11....
Transcript of TEST REPORT - Maxlifemaxlife.nz/uploads/1/7/9/2/17921577/intertek_test_report... · 2019. 11....
- The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
PAGE 1 OF 22
Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT
Number: HK13030903-1 Applicant: PKG Maxlife 136 Motu Road, Kumeu, Auckland, NZ
Date: 8 April 2013
Sample Description Product : AA ALKALINE BATTERIES Brand Name : Maxlife / Duracell / Energizer / Eveready / E-tech / Chevron / Warrior / Dick Smith / Arlec / Zone
Model No. : Maxlife – Alkaline / Duracell – Coppertop / Energizer – Max / Eveready – Gold / E-tech – Alkaline / Chevron – Alkaline / Warrior – Alkaline / Dick Smith – Exxtra Plus Alkaline / Arlec – Alkaline / Zone – Alkaline
Electrical Rating : 1.5V No. of Samples : 9 (Nine) per brand Date Received : 20 March 2013 Date Test Conducted : 21 March 2013 to 4 April 2013 Test Requested : IEC 60086-1: 2011
1. Clause 4.2.1 - Discharge Performance AA type battery discharge performance test for an application of Digital still camera for reference test condition
Test Method : IEC 60086-1: 2011 in conjunction with IEC 60086-2 Test Results : See the attached sheets Conclusion : See the attached sheets Remark : When determining the test conclusion, the Measurement
Uncertainty of test has been considered.
********************************************* End of Page *********************************************** Reviewed by : ____________________ Kong Ka Hang, Felix Assistant Manager
PAGE 2 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 A COMPARISON MATRIX FOR DIFFERENT BRANDS Test result:
Average Discharge Duration Time (pulses) Brand Application of Digital still camera Complied With The Acceptance
Criteria
Maxlife 98 Yes Duracell 55 Yes
Energizer 79 Yes Eveready 53 No (See note 1)
E-tech 54 Yes Chevron 95 Yes Warrior 66 Yes
Dick Smith 90 Yes Arlec 73 Yes Zone 63 Yes
Note 1: The average is greater than the minimum average duration, however more than one
battery has a service output of less than 80 % of the minimum average duration (30 pulses). Therefore the batteries are NOT complied with the acceptance criteria.
*********************************************** End of Page ************************************************
PAGE 3 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 1. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Maxlife
Datecode: 11-2019
Sample Number
Discharge Duration Time (Pulses)
1 106 2 107 3 97 4 97 5 88 6 98 7 97 8 104 9 88
Average: 98 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 4 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 2. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Duracell
Datecode: MAR 2017
Sample Number
Discharge Duration Time (Pulses)
1 47 2 55 3 59 4 58 5 56 6 54 7 57 8 57 9 58
Average: 55 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 5 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 3. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Energizer
Datecode: 03-2023
Sample Number
Discharge Duration Time (Pulses)
1 75 2 85 3 79 4 78 5 79 6 78 7 77 8 78 9 87
Average: 79 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 6 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 4. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Eveready
Datecode: 03-2016 for sample number 1 - 8 & 03-2017 for sample number 9
Sample Number
Discharge Duration Time (Pulses)
1 69 2 58 3 58 4 57 5 26 6 47 7 66 8 27 9 74
Average: 53 The average is greater than the minimum average duration, however more than one battery has a service output of less than 80 % of the minimum average duration (32 pulses). Therefore the batteries are NOT complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 7 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 5. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: E-tech
Datecode: 02-2016
Sample Number
Discharge Duration Time (Pulses)
1 59 2 54 3 58 4 47 5 56 6 48 7 54 8 58 9 58
Average: 54 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 8 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 6. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Chevron
Datecode: 01-2016
Sample Number
Discharge Duration Time (Pulses)
1 99 2 97 3 97 4 96 5 99 6 79 7 97 8 96 9 99
Average: 95 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 9 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 7. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Warrior
Datecode: 09-2015
Sample Number
Discharge Duration Time (Pulses)
1 67 2 66 3 67 4 65 5 66 6 66 7 66 8 66 9 68
Average: 66 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 10 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 8. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Dick Smith
Datecode: 01-2017
Sample Number
Discharge Duration Time (Pulses)
1 89 2 87 3 86 4 86 5 96 6 88 7 96 8 89 9 96
Average: 90 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 11 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 9. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Arlec
Datecode: 06-2017
Sample Number
Discharge Duration Time (Pulses)
1 77 2 77 3 49 4 77 5 77 6 77 7 78 8 69 9 79
Average: 73 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 12 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Number : HK13030903-1 10. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result:
Results are recorded as below.
Brand: Zone
Datecode: 08-2017
Sample Number
Discharge Duration Time (Pulses)
1 67 2 66 3 56 4 55 5 67 6 65 7 67 8 64 9 64
Average: 63 The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************
PAGE 13 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Maxlife
*********************************************** End of Page ************************************************
PAGE 14 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Duracell
*********************************************** End of Page ************************************************
PAGE 15 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Energizer
*********************************************** End of Page ************************************************
PAGE 16 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Eveready
*********************************************** End of Page ************************************************
PAGE 17 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
E-tech
*********************************************** End of Page ************************************************
PAGE 18 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Chevron
*********************************************** End of Page ************************************************
PAGE 19 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Warrior
*********************************************** End of Page ************************************************
PAGE 20 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Dick Smith
*********************************************** End of Page ************************************************
PAGE 21 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Arlec
*********************************************** End of Page ************************************************
PAGE 22 OF 22 Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
TEST REPORT Product Photo Number : HK13030903-1
Zone
****************************************** End of Report *******************************************