TERMINAL LEARNING OBJECTIVE
ACTION: Perform COFT Operations
CONDITION: Given a COFT, COFT IUH, and in a classroom environment
STANDARDS: I/O student must demonstrate knowledge of proper COFT training by achieving 80% or higher on the I/O end of course exam and achieve an overall “GO” on all hands on test
![Page 3: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/3.jpg)
COFT SAFETY BRIEFING
SAFETY:
• Tampering with equipment is prohibited and horseplay will not be tolerated
• CVC helmets must be worn in the Crew Station at all times
• No food, drinks, smoking or smokeless tobacco are allowed in the training area
• Use all required references during maintenance and training
• Do not walk on or move any cables, or touch any electrical connections
![Page 4: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/4.jpg)
COFT SAFETY BRIEFING (Con’t)
• Know the location and function of the three Emergency Shutdown Switches
• Know where the fire extinguishers are, how to use them, the location of emergency exits and the Shelter Emergency Shutdown Switches
• Observe all CAUTION and WARNING labels throughout the trainer
• Do not permit any activity in the COFT that is unsafe in the BFV
![Page 5: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/5.jpg)
Risk Assessment Level: Moderate, due to potential for exposed high voltage cables
Environmental Considerations: None
Evaluation: I/O student must demonstrate knowledge of proper COFT training by achieving 80% or higher on the I/O end of course exam and achieve an overall “GO” on all hands on test
![Page 6: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/6.jpg)
ENABLING LEARNING OBJECTIVE A
ACTION: Identify COFT Components and Characteristics
CONDITION: Given a COFT, COFT IUH, and classroom instruction
STANDARDS: Student must adhere to policies and procedures throughout entire I/O course
![Page 7: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/7.jpg)
• Crew Station
• Instructor/Operator Station (IOS)
• Computer Rack
MAJOR COMPONENTS
![Page 8: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/8.jpg)
CREW STATION
![Page 9: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/9.jpg)
INSTRUCTOR OPERATOR STATION (IOS)
![Page 10: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/10.jpg)
COMPUTER RACK
The computer rack consists of the following components:
PrinterModSAF ComputerIOS ComputerIG1 ComputerIG2 ComputerBVE ComputerKVM Switcher
![Page 11: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/11.jpg)
ENABLING LEARNING OBJECTIVE B
ACTION: Perform COFT Power Up
CONDITION: Given a COFT, COFT IUH, and in a classroom environment
STANDARDS: Successfully power up the COFT IAW with IUH
![Page 12: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/12.jpg)
Power Up Procedure
Shelter Preconditioning Procedures
Shelter Door Vent
Fire Protection Panel
Shelter Lighting SwitchesEmergency Light
![Page 13: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/13.jpg)
Power Up Procedure
Shelter Preconditioning Procedures
Door Locking Pin
Air Conditioner Louvers
Hygrometer/Thermometer
Observe the hygrometer/thermometer in the Training Shelter. If the temperature reading is between 60º F and 90ºF (15ºC and 30ºC) and relative humidity is between 20 and 70 percent, refer to (ADD TM #), Unusual Electronic Equipment Power-Up Procedure
![Page 14: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/14.jpg)
Power Up Procedure
A/C Mode Selector
Shelter A/C Mode Selector Switch Setting
Outside Temperatur
e Ranges
ComputerShelter
TrainerShelter
IntecShelter
51AC1 51AC2 51AC3 52AC1 53AC1
-40ºF to -5ºF-40ºC to -20ºC
Vent Heat Cool Heat Heat
-5ºF to 20ºF-20ºC to 6.7ºC
Vent Heat Cool Cool Heat
20ºF to 68ºF-6.7ºC to 20ºC
Cool Vent Cool Cool Heat
68ºF to 80ºF20ºC to 26.7ºC
Cool Vent Cool Cool Cool
80ºF to 125ºF26.7ºC - 51.7ºC
Cool Cool Cool Cool Cool
Humidifier Tank Water Level Gage
![Page 15: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/15.jpg)
Power Up Procedure
Main Circuit Breaker
Circuit Breakers 2 and 6
![Page 16: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/16.jpg)
Power Up Procedure
Main Power 208VAC
MainCircuit Breaker
AC ON Lamp
![Page 17: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/17.jpg)
Power Up Procedure
Key-switch AC ON Lamp
Once the key-switch is turned on, wait until the monitor displays the System Startup screen before continuing
![Page 18: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/18.jpg)
System Start Up
![Page 19: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/19.jpg)
Power Up Procedure
Crew StationAuxiliary Equipment
AC ON Lamps
DC Power Lamps
![Page 20: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/20.jpg)
Power Up Procedure
AC ON Lamp
Crew Station (CFP/ISUW)
![Page 21: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/21.jpg)
Power Up Procedure
AC ON Lamp
AC ON Lamp
Intercom & Test equipment
Crew Compartment Power
Brow Pad
![Page 22: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/22.jpg)
System Start Up
![Page 23: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/23.jpg)
System Start Up
![Page 24: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/24.jpg)
ENABLING LEARNING OBJECTIVE C
ACTION: Manage COFT Time Logbook
CONDITION: Given a COFT, COFT IUH, and in a classroom environment
STANDARDS: Manage system logbook in accordance with IUH TM 9-6930-712-12
![Page 25: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/25.jpg)
COFT TIME LOGBOOK
SIGNATURE
Ernie Lindquist
Ernie Lindquist
Brad Tesch (FSR)
Ernie Lindquist
Ernie Lindquist
Ernie LindquistBrad Tesch (FSR)
Ernie Lindquist
Ernie Lindquist
MIN
30
ACCOUNTABLEFAILURE TIME
HRS
3
5
BLDG 5500LOCATION: Fort Benning
ETM
123.1
128.3
128.3
140.5
140.5
142.3
142.3
152.1
SERIAL NO. 4962
REMARKS
Power up
Power down
Power up
WCB: HE ammo would not selectNotified FSR
Replaced ammo selection switch
Power down
Power upCTD power went down
Notified FSR
Power up
Power down
TIME (00:00)
14:00
19:00
06:00
18:25
11:25
17:00
03:00
09:30
15:00
23:00
COFT SYSTEM LOGDAILY OPERATIONS
DATE(MMDDYY)
01/05/03
01/05/03
01/06/03
01/06/03
01/06/03
01/06/03
01/07/03
01/07/03
01/07/03
01/07/03
DA FORM XXX-A-R
![Page 26: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/26.jpg)
ENABLING LEARNING OBJECTIVE D
ACTION: Perform Instructor Login and Log Off
CONDITION: Given a COFT, COFT IUH, and in a classroom environment
STANDARDS: Successfully perform COFT Instructor Login and Log Off procedures in IAW, IUH TM 9-6930-712-12
![Page 27: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/27.jpg)
System Login
![Page 28: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/28.jpg)
2/8IN A11
INSTRUCTOR LOG OFF
Log Off
![Page 29: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/29.jpg)
ENABLING LEARNING OBJECTIVE E
ACTION: Perform COFT Power-down
CONDITION: Given a COFT, COFT IUH, and in a classroom environment
STANDARDS: Successfully Power-down the COFT, in sequence and in accordance with IUH TM 9-6930-712-12
![Page 30: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/30.jpg)
Power Down Procedure
Quit
![Page 31: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/31.jpg)
Power Down Procedure
Viewgraph J-17
![Page 32: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/32.jpg)
Power Down Procedure
Ensure Power Lamps go off
Last computer Lamp remains on
![Page 33: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/33.jpg)
Power Down Procedure
Main Circuit BreakerCrew Station (CFP/ISUW)
Key-switch
Crew StationAuxiliary Equipment)
![Page 34: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/34.jpg)
TERMINAL LEARNING OBJECTIVE
ACTION: Perform COFT Operations
CONDITION: Given a COFT, COFT IUH, and in a classroom environment
STANDARDS: I/O student must demonstrate knowledge of proper COFT training by achieving 80% or higher on the I/O end of course exam and achieve an overall “GO” on all hands on test
![Page 35: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/35.jpg)
SUMMARY
ELO A: Identify COFT Components and Characteristics
ELO B: Perform COFT Power-up
ELO C: Manage COFT Time Logbook
ELO D: Perform Instructor Logoff
ELO E: Perform COFT Power-down
![Page 36: TERMINAL LEARNING OBJECTIVE ACTION: Perform COFT Operations CONDITION: Given a COFT, COFT IUH, and in a classroom environment STANDARDS: I/O student must.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649e725503460f94b71327/html5/thumbnails/36.jpg)