MAY 10, 2016
TENANT DESIGN MANUAL
DINING PAVILION
WOODFIELD MALLa simon mall
4.0 SIGNAGE EXHIBITSSIGNAGE OVERVIEWACCEPTABLE PRIMARY SIGNAGEPRIMARY SIGNAGESECONDARY SIGNAGE
5.0 DETAIL REVIEWFINISH MATERIALSCEILING & LIGHTINGMENU BOARDSMENU EXAMPLESEXHAUST HOODSPRESENTATION CONCEPTS
6.0 HVAC/MEP TENANT HVACTENANT MEPMEP FORMS
18192021
222324252627
282930
1.0 GENERAL INFORMATION
PROJECT LOCATIONPROJECT OVERVIEWHOW TO USE THIS MANUALTENANT INFORMATION PACKAGESITE PLANFLOOR PLAN
2.0 INLINE TENANTS
IN-LINE PERSPECTIVEWORK DISTRIBUTIONTYPICAL ELEVATIONTYPICAL SECTIONTYPICAL PLANTYPICAL RCPTENANT EXAMPLES
3.0 KIOSK TENANTS
KIT OF PARTSTENANT EXAMPLES
030405060708
09101112131415
1617
TABLE OF CONTENTS
2SIMON
PROJECT LOCATION
Woodfield Mall is a shopping mall located in the northwest Chicago suburb of Schaumburg, Illinois, United States, at the intersection of Golf Road and Interstate 290.
1.0 GENERAL INFORMATION
3SIMON
PROJECT OVERVIEW
STATEMENTTo create and completely redefine the “food experience” at Woodfield Mall through thoughtfully placed and arranged architectural events, natural sunlight, finish materials and finishes all within a new, family friendly environment.
GOALSCreate a unique, fashionable, stimulating and family friendly food destination.
STRATEGY• To collectively create an all new food experience.• Encourage brand presentation strength within tenant designs.• Encourage design for strongest visibility.• Engage with new façade and seating pavilion that focuses on entry as a
statement.• Enhance seating clusters with simple diversity of fixtures, amenities and
floor treatments.
4SIMON
HOW TO USE THIS MANUAL
This manual outlines design criteria guidelines, requirements and recommendations which have been developed by the Landlord for the purpose of assisting the Tenants of the Woodfield Mall Dining Pavilion in the development of their leased spaces.
The criteria guidelines help maintain a consistent design quality while still allowing flexibility. Thus, each Tenant can achieve a high level of individual brand expression and diversity within their materials, lighting, signage and menu boards. In this regard, the Landlord requests innovative solutions from each Dining Pavilion tenant, which in the collective context provides for a richer experience for all visitors.
Tenants and their designers must acquaint themselves thoroughly with the material herein so their design and construction can proceed in a coordinated and timely manner.
Tenants are required to employ competent professionals in the fields of design and contracting relative to their development work. It is essential that the Tenant and/or designer visit the site to inspect and verify all site conditions prior to the commencement of Tenant design.
All questions, submissions and proposals relative to Tenant work should be directed to your Tenant Coordinator.
5SIMON
TENANT INFORMATION PACKAGE
The Tenant Information Package (TIP) is intended to provide you with the project’s design and construction criteria and consists of several parts:
To access the Tenant Information Package:
• The Tenant Information Package can be accessed from Simon’s website www.simon.com.
• Select the “Business” tab, search for the property name, click on the “Tenant Info Package” link on the lower right side of the page.
• If you have difficulties working with the website, please contact your Tenant Coordinator.
• Tenant design professionals may access design criteria, base building drawings and other information required to develop and complete tenant drawings on Buzzsaw by contacting their Tenant Coordinator.
* For questions regarding the Landlord design and construction requirements, please contact your Tenant Coordinator. Tenant to field verify all lease conditions.
COMPONENT DESCRIPTIONTIP Index
Tenant Design Manual
Architectural Criteria
MEP/FP Criteria
Bulletins
Woodfield Guidelines
Will provide a comprehensive list of topics to help locate information
Provide mall specific architectural, sign and engineering design criteria
Outlines submission requirements and will provide necessary guidelines to design your store
(same as Architectural Criteria)
Bulletins & Updates
Site specific guidelines for Woodfield Mall
6SIMON
290
90
70
SCALE: NTS
SEARS
LORD &TAYLOR
JCPENNEY
MACY’S
NO
RDST
ROM
DININ
G
PAVILION
SITE PLAN
WOODFIELD MALL
BUILDING PLANSCALE: NTS
LEGEND
ENTRANCES
DINING PAVILION
MALL RETAIL CONCOURSE
SITE PLAN
7SIMON
02030405
09
010607
08 10 11 12
K01
K02
FLOOR PLANSCALE: NTS
LEGENDINLINE TENANT
KIOSK TENANT
WASHROOMRETAILTENANT
FLOOR PLAN
8SIMON
NEUTRAL PIER & FINISHES BY
LANDLORD
ACCESS TO BACK OF HOUSE (LOCATION WILL VARY BY
TENANT) FINISH TO MATCH FRONT OFHOUSE
COUNTER TOP, FACE & BASE BY TENANT TO LANDLORD
SPECIFICATIONS
SECONDARY SIGNAGE BY TENANT PER LANDLORD
CRITERIA
TENANT HOOD SUBJECT TO LANDLORD APPROVAL
TENANT PRIMARY SIGNAGE
TENANT MENU
TENANT CONTROL
SCALE: NTS
TENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
INLINE PERSPECTIVE
2.0 INLINE TENANTS
9SIMON
WORK DISTRIBUTION
LEGEND
SCALE: NTS
BY LANDLORD BY TENANTTENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
10SIMON
SCALE: NTS ACCESS TO BACK OF HOUSE (LOCATION WILL VARY
BY TENANT)
STAINLESS STEEL DEMISING WALL/CAP/TRIM & FRITTED GLASS BY LANDLORD. REFERENCE SECONDARY SIGNAGE (P.22)
COUNTER TOP, FACE & BASE BY TENANT TO LANDLORD SPECIFICATIONS
TENANT MENU BOARD ZONE
TENANT PRIMARY SIGNAGE ZONE ZONE CONTROL EXTENDS TO MINIMUM OF 48”
FROM NEUTRAL PIER & ACHEIVES MAXIMUM 12’-0” IN LENGTH
ADJACENTTENANT TENANT
VARIES
ADJACENTTENANT
2’-0”
MIN.
2’-0”
MIN.
TENANT HOOD ZONE
INTERNALLY ILLUMINATED STAINLESS STEEL SIGN BOX BY LANDLORD, PUSH THROUGH ACRYLIC LETTERS & STAINLESS STEEL FACE PLATE BY TENANT PER LANDLORD SPECIFIED FABRICATOR. REFERENCE SECONDARY SIGNAGE (P.22)
HO
OD
HT.
PE
R. C
OD
E
8’-0
” M
IN.
LEGEND
PRIMARY/SECONDARY SIGNAGE
BY LANDLORD
BY TENANT
DEMISING WALL
TENANT HOOD ZONE
LEASE LINE
TENANT COUNTER ZONE TENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
TYPICAL ELEVATION
11SIMON
BACK OF HOUSE
4’-0
”
13’-6
”
SCALE: NTS
4’-6
”
3’-6
” M
AX
DIS
PLA
Y
3’-0
” C
OU
NTE
R H
T
1’-10.5”
1.5”
3’-2” 3’-10” 2’-0”
3’-6”
TENANT
LANDLORD LIGHTING
CEILING FINISHES & LIGHTING BY TENANT TO LANDLORD SPECIFICATIONS
COUNTER TOP, FACE & BASE BY TENANT TO LANDLORD SPECIFICATIONS
MALL TILE BY LANDLORD TO EXTEND 1’-0” INTO TENANT LEASELINE
INTERNALLY ILLUMINATED STAINLESS STEEL SIGN BOX BY LANDLORD, PUSH THROUGH ACRYLIC LETTERS & STAINLESS STEEL FACE PLATE BY TENANT PER LANDLORD SPECIFIED FABRICATOR. REFERENCE SECONDARY SIGNAGE (P.22)
DEMISING WALL & FINISHES BY TENANT TO
LANDLORD SPECIFICATIONS.
1’-0”
8’-6” DEMISING WALL
9’-0” SERVICE AREA
6”
HO
OD
HT.
PER
. CO
DE
1’-6”
LEGEND
PRIMARY/SECONDARY SIGNAGE
BY LANDLORD
BY TENANT
DEMISING WALL
TENANT HOOD ZONE
LEASE LINE
TENANT COUNTER ZONE
STAINLESS STEEL DEMISING WALL/CAP/TRIM & FRITTED GLASS BY LANDLORD. SIGNAGE BY TENANT TO LANDLORD SPECIFICATIONS. REFERENCE SECONDARY SIGNAGE (P.22)
TENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
TYPICAL SECTION
12SIMON
TENANT
VARIES
BACK OF HOUSE5’-0” MIN.
3’-6
” M
IN.
ADJACENTTENANT
VA
RIES
3’-6
”6”
ADJACENTTENANT
1’-0”
8’-0
”
APPROX LOCATION OF FRONT TENANT COUNTER BY TENANT TO LANDLORD SPECIFICATIONS
STAINLESS STEEL DEMISING WALL/CAP/TRIM & FRITTED GLASS BY LANDLORD. SIGNAGE BY TENANT TO LANDLORD SPECIFICATIONS. REFERENCE SECONDARY SIGNAGE (P.22)
TENANT FLOOR TILE BY TENANT TO LANDLORD SPECIFICATIONS
LOCATION OF MENU GRAPHICS BY TENANT TO LANDLORD SPECIFICATIONS
MALL TILE BY LANDLORD TO EXTEND
1’-0” INTO TENANT LEASELINE
DEMISING WALL & FINISHES BY TENANT TO
LANDLORD SPECIFICATIONS.
TENANT FRONT OF HOUSE FINISHES TO EXTEND TO
CUSTOMER FACING WALL SURFACES
BOH LOCATOR WALL BY TENANT
CONFIGURED IN A MANOR THAT BLOCKS
VIEW OF BOH FROM COUNTER
INTERMEDIATE WALL BY TENANT TO LANDLORD SPECIFICATIONS & LOCATION
SCALE: NTS
LEGEND
PRIMARY/SECONDARY SIGNAGE
BY LANDLORD
BY TENANT
DEMISING WALL
TENANT HOOD ZONE
LEASE LINE
TENANT COUNTER ZONETENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
TYPICAL PLAN
TYPICAL PLAN
13SIMON
TENANT PRIMARY SIGNAGE ZONE ZONE CONTROL EXTENDS TO MINIMUM OF 4’0”
FROM NEUTRAL PIER & ACHEIVES MAXIMUM 12’-0” IN LENGTH
DEMISING WALL & FINISHES BY TENANT TO LANDLORD
SPECIFICATIONS.
DEMISING WALL WITH GLASS, STAINLESS STEEL
CAP AND TRIM BY LANDLORD & TENANT SIGNAGE. REFERENCE
SECONDARY SIGNAGE (P.22)
ADJACENTTENANT
9’-0
”
2’-0” 2’-0”
4’-0” 4’-0”
ADJACENTTENANT
LANDLORD CEILING COVE & DIRECTIONAL LIGHTING
(DIRECTIONAL LIGHTING FOR TENANT USE)
INTERMEDIATE WALL BY TENANT TO LANDLORD SPECIFICATIONS & LOCATION
BOH LOCATOR WALL BY TENANT CONFIGURED IN A
MANOR THAT BLOCKS VIEW OF BOH FROM COUNTER
TENANT FRONT OF HOUSE
FINISHES TO EXTEND TO CUSTOMER FACING WALL
SURFACES
TENANT HOOD ZONE SUBJECT TO LANDLORD APPROVAL
TENANT
5’-0” MIN.
VARIES
3’-6
” M
IN.
VA
RIES
3’-2
”3’
-4”
6”2’
-0”
1’-0”
BACK OF HOUSE
SCALE: NTS
LEGEND
PRIMARY/SECONDARY SIGNAGE
BY LANDLORD
BY TENANT
DEMISING WALL
TENANT HOOD ZONE
LEASE LINE
TENANT COUNTER ZONE TENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
TYPICAL RCP
14SIMON
BEFORE BEFORE
BEFORE BEFORE
AFTER AFTER
AFTER AFTER
TENANT EXAMPLES
15SIMON
INTEGRATED LOW SECONDARY SIGNAGE ON OPPOSING SIDES PERPENDICULAR TO PRIMARY SIGNAGE
INTEGRATED INTERNALLY ILLUMINATED MONUMENT PRIMARY SIGN BY TENANT PER LANDLORD REVIEW
CUSTOMER SIDE OF TALL WALLS TO BE TREATED AS SEATING, GRAPHICS & BRANDED OPPORTUNITIES PER LANDLORD REVIEW
EXHAUST HOOD ( OPTIONAL )TENANT’S HOOD MUST BE CLAD IN
STAINLESS STEEL WITH HIGH QUALITY DETAILING. HEIGTH, SIZE AND
LOCATION WILL BE REVIEWED ON A CASE BY CASE BASIS.
DIGITAL MENU BOARDS BY TENANT.MENU BOARD STYLE, LOCATION
AND MOUNTING METHOD PER LANDLORD REVIEW.
OPPORTUNITY FOR MERCHANTDISING,DISPLAY CASES BY TENANT
PER LANDLORD REVIEW.
LEGEND
PRIMARY/SECONDARY SIGNAGE
TENANT HOOD ZONE
MENU BOARD
DISPLAY CASE
KIT OF PARTS
3.0 KIOSK TENANTS
16SIMON
TENANT EXAMPLES
17SIMON
Tenant signage is for the purpose of identification only and must be limited to trading name and logo. The sign must not exceed 12’ maximum of the signage zone length.
Advertising of product names may not be displayed as part of the signage. Advertising of tenant e-mail or web address by means of duratrans, decal vinyl stickers, will not be permitted. Other graphics are subject to approval.
All signage is to be of the highest quality design and construction. Tenant signage shall be designed to be proportionate in scale to the elevation to which it is affixed. Use of the National Corporate Logo’s and/or insignia is encouraged. All attachments, labels, fasteners, mounting brackets, wiring, clips, transformers, disconnects, lamps (except exposed neon tubes) and other mechanisms required for all signage shall be concealed from view. Light leaks are not permitted.
Illuminated signs must be connected to a 7-day, 24-hour time clock set to the hours specified by the Mall Management.
´ Taglines (regardless of DBA) and signs advertising products, services or vendors.
´ Box or cabinet type construction where the outline of the box or cabinet is visible (the box or cabinet must be fully embedded into the intermediate wall framing and finish).
´ Signs employing audible equipment, and/or moving, flashing, or blinking lights.
´ Signs employing exposed raceways, ballast boxes, or transformers.
´ Sign manufacturers’ names, stamps or decal.
´ Signs employing luminous vacuum formed type plastic letter signs.
´ Signs employing unedged or uncapped plastic letters with no returns and exposed fastenings.
´ Paper or cardboard signs, stickers, or decals.
´ Exposed tube neon signs (except for open face channel letters).
´ Moving, rotating and noise making sign.
´ No exposed registered trademarks.
• Internally illuminated individual channel letters with opaque metal sides and acrylic plastic face.
• Metal letters backlit to produce a “halo” effect.
• Edge-lit, sandblasted glass.
• Gold leaf or silk screened on front of backlit tempered glazing.
• All letters shall be of fully welded construction.
• All electrical signage shall bear the UL label and must comply with all governing codes.
• All conduit, raceways, crossovers, wiring, ballast boxes, transformers, and other equipment necessary for sign connection shall be concealed.
NOT-PERMITTED SIGNAGE
PERMITTED SIGNAGESIGNAGE OVERVIEW
4.0 SIGNAGE EXHIBITS
18SIMON
Renderings & images for illustrative purposes only
DIMENSIONAL BACKLIT
FACE LIT
ACRYLIC LETTERS
BACK & EDGE LIT
BACKLIT
EDGE LIT
LASER CUT
ROUTED MATERIAL
ACCEPTABLE PRIMARY SIGNAGE
19SIMON
INTERNALLY ILLUMINATED STAINLESS STEEL SIGN BOX BY LANDLORD, PUSH THROUGH ACRYLIC LETTERS & STAINLESS STEEL FACE PLATE BY TENANT PER LANDLORD SPECIFIED FABRICATOR. REFERENCE SECONDARY SIGNAGE (P.22)
TENANT PRIMARY SIGNAGE ZONE. CONTROL EXTENDS TO MINIMUM SEPERATION SPACE OF 48” FROM NEUTRAL PIER & ACHIEVES MAXIMUM 12’-0” IN LENGTH
ADJACENTTENANT
ADJACENTTENANTTENANT
ACCESS TO BACK OF HOUSE (LOCATION WILL
VARY BY TENANT)
2’-0”
MIN.
2’-0”
MIN.
TENANT HOOD ZONE
8’-0
” M
IN.
4’-0” 4’-0”
LEGEND
PRIMARY/SECONDARY SIGNAGE
BY LANDLORD
BY TENANT
DEMISING WALL
TENANT HOOD ZONE
LEASE LINE
TENANT COUNTER ZONE TENANT IS RESPONSIBLE TO CONFIRM AND FIELD VERIFY ALL SITE CONDITIONS PRIOR TO CONSTRUCTION
PRIMARY SIGNAGE
20SIMON
Secondary Signage PerspectiveScale: NTS
NEUTRAL PIER SUBSTRATE BY LANDLORD, FINISHES BY TENANT TO LANDLORD
SPECIFICATIONS
4’-6” STAINLESS STEEL DEMISING WALL BY LANDLORD
DEMISING WALL FRITTED GLASS BY
LANDLORD
INTERNALLY ILLUMINATED STAINLESS STEEL SIGN BOX BY
LANDLORD, PUSH THROUGH ACRYLIC LETTERS & STAINLESS STEEL FACE PLATE BY TENANT
PER LANDLORD SPECIFIED FABRICATOR
Secondary Signage Perspective DetailScale: NTS
STAINLESS STEEL FRAMED INTERNALLY ILLUMINATED WHITE ACRYLIC LIGHT BOX BY LANDLORD
PUSH THROUGH ACRYLIC LETTERS BY TENANT TO LANDLORD SPECIFICATIONS
STAINLESS STEEL FACE PLATE BY TENANT TO LANDLORD SPECIFICATIONS
SECONDARY SIGNAGE
Secondary Signage ElevationScale: NTS
Tenant secondary signage is to be a Stainless Steel Sign Face that has Tenant logo cut out and is Illuminated with internal White Acrylic Landlord supplied Light Box.
Tenant to Submit Logo Artwork and/or Graphics to Landlord for Approval Prior to Execution of Sign.
21SIMON
TEMPERED GLASS
DECORATIVE GLASS MOSAIC TILE
STAINLESS STEEL
STONE
TEXTURED METAL
PORCELAINWOOD
ACRYLIC
FINISH MATERIALS
• All materials are to be installed over a durable substrate and must be long lasting with minimal maintenance required.
• All Tenants shall comply with all governing and applicable building and fire code requirements.
• The Landlord reserves the right to reject or request substitutions or adjustments to the proposed finishes.
• All materials must be approved by the Landlord prior to installation. Nothing is to be Overlaid over the Landlord’s Decorative Finishes.
• Finish-grade figured hardwood, stained and/or lacquered
• Quality porcelain
• Stainless steel and chrome
• Honed, polished or bush hammered natural stone
• Decorative, sandblasted, stained, or etched glass
• Mosaic tiles
• Polished, brushed or textured metals
• Tempered glass
• Quality acrylic surfaces, polyester resin
*Service Area is all Visible Area Forward of Back of House Partitions
PERMITTED IN SERVICE AREA
5.0 DETAIL OVERVIEW
22SIMON
TENANT CEILING & LIGHTING
• Drywall ceiling in service area by Tenant to Landlord specifications, installed by Tenant.
• Additional lighting, (general, task or decorative) will be considered and is subject to Landlord review and approval.
• The use of fluorescent lighting is not permitted.
• Sprinkler heads in the ceiling shall be fully recessed type with cover plates or concealed in the design.
LANDLORD CEILING LIGHTING
Single Recessed downlight fixture by Cooper Lighting. 6” Halo LED module 1200 Series. Specular reflector with white trim ring.
TENANT CEILING & LIGHTING
Additional lighting, (general, task or decorative), will be considered
over plates or concealed in the design.
NOT ALLOWED IN SERVICE AREALIGHTING TYPE B3:SINGLE RECESSED DOWNLIGHT FIXTUREBY COOPER LIGHTING6” HALO LED MODULE 1200 SERIES #494SC06SPECULAR REFLECTOR WITH WHITE TRIM RING
´ Unfinished Gypsum.
´ Paint Finishes (Non-Ceiling Surfaces).
´ Faux Finishes.
´ Vinyl Wallcoverings.
´ Plastic Laminates.
´ Carpet.
´ Neon lighting.
´ Exposed, surface mounted or suspended fluorescent lighting.
NOT ALLOWED IN SERVICE AREA
CEILING & LIGHTING
23SIMON
In order to maintain a pleasant and high quality food service ambiance, Tenants are encouraged to use well designed, non-commercial menu boards in their stores. Menu board designs must be reviewed and approved by the Landlord before construction. Below is a list of requirements:
• Integrated Digital screens will be used for the menu boards by all Tenant’s.
• All Digital screen menu’s will be integrated into the back wall design and are a part of the overall design concept.
• Digital screen frames will be concealed in a unique and innovative way.
´ No Printed Menu Boards.
´ No mechanical attachments or electrical facilities can be visible.
´ No more than an area of 50% illustrations will be permitted on the menu boards.
´ No gratuitous advertising panels or illustrations other than Menu boards will be permitted.
• Maximum Height: 48”.
• Menu Boards to be mounted to back wall.
• Maximum of 4 digital menu boards allowed.
NOT PERMITTED MENU BOARDS
NOTE:
MENU BOARDS
24SIMON
MENU EXAMPLES
25SIMON
EXHAUST HOOD AND BULKHEAD TREATMENTS
Tenant’s Hood must be clad in a stainless steel box with high quality detailing. Hood must be located behind the lease line attached to the back wall.
All Signage over or applied to Hood is subject to Landlord approval.
´ Exposed non-clad Hoods will not be accepted.
´ No tenant hoods on the front counter.
NOT PERMITTED HOODS NOTE:
EXHAUST HOODS
26SIMON
PRODUCT PRESENTATIONTEXTURED FINISHES INTEGRATED GRAPHICS
MATERIALS
PRESENTATION CONCEPTS
27SIMON
This is an enclosed rooftop unit mall. Engineer is required to accommodate conditions that may affect the performance of the HVAC system for their store.
• Equipment - Down flow rooftop unit on full curb with electric heat if required. Split systems are allowed with Landlord approval. Unit(s) to be located in designated structural bays. Modify existing roof structure to support equipment.
• Condensate Drain - Condensate to be piped from rooftop unit to an approved connection location.
• HVAC Load Calculation - Tenant to submit a detailed computer generated load calculation to justify equipment sizing. Tenants room temperature shall be 75°.
• Outside/Relief Air - Economizer and barometric or fan powered relief through Tenant installed components per code.
• Return - Plenum (Ducted return for odor producing Tenants only and subject to Landlord approval.
• Toilet Exhaust - By Tenant, including fan, ductwork and roof cap.
• Odor, & Process Equipment Exhaust - Size for application by Tenant.
• Temperature Controls - Stand-alone digital electric/
electronic control system by Tenant.
• Test & Balance - Tenant shall employ a TAB, NEBB or AABC Certified Air Balance Contractor to perform final testing and balancing.
• Roof Repair/Replacement - Refer to the Tenant Information Package (TIP) (page 6) to access The Woodfield Mall roof consulting & roofing replacement documents.
• See Criteria Sheet MEP-1 for further information.
TENANT HVAC
6.0 HVAC/MEP
28SIMON
PLUMBING
• Water - Redistributed by Landlord via overhead mains with 1-1/4” valve connection.
• Waste - 4” connection off Landlord main. Designated connection point within or adjacent to space.
• Vent - Connect to Landlord common or through roof by Tenant.
• Natural Gas - No gas for kiosk tenants.
• Toilet Rooms - Per code.
• Drinking Fountain - Per code.
• Service Sink - As required by code or Authority Having Jurisdiction.
• Floors - Full waterproofing under all finished flooring is required.
• See Criteria Sheet MEP-1 for further information.
FIRE PROTECTION
• Implementation - Tenant shall directly employ the Landlord designated contractor to install and/or modify existing grid or utilize connection provided.
• Tenant Flow Switch - Not Permitted.
• Valve for Tenant Space - Not Permitted.
• See Criteria Sheet MEP-1 for further information.
ELECTRICAL
• Voltage - 277/480 volt, 3ph, 4-wire.
• Landlord Equipment - Landlord provided electrical conduit and pull string. Feeder cables are by the Tenant.
• Power - Provided by local utility.
• Metering - Tenant to provide disconnect, meter and connect to Landlord meter bank per local utility company.
• Capacity - Tenant maximum connection is 20 watts per square foot. Submit connected and demand electrical load data to support electric service size requested.
• Telephone - 1” minimum conduit with pull string to designated connection point in central locations.
• Fire Alarm - Interface with Landlord system is only required when the Tenant occupancy requires a system to meet Code. Tenant to tie into Landlord’s system. Duct detectors to shut down RTU equipment to be annunciated within Tenant space only.
• See Criteria Sheet MEP-1 for further information.
TENANT MEP
29SIMON
MEP CALCULATION FORMS:
Tenant’s Engineer shall use their own form for HVAC Load Calculations:
• Appliance Heat Gain
• Electrical Load Summary
• Kitchen Exhaust Fan Specifications
• Kitchen Make-up Air Unit Specification
• RTU/Split System Specifications
• Maintenance
MEP FORMS
30SIMON