Template Instructions En
-
Upload
dragomir-vasic -
Category
Documents
-
view
214 -
download
0
Transcript of Template Instructions En
-
7/31/2019 Template Instructions En
1/8
Introduction
AllCovenantsignatoriescommittosubmittingtheirSustainableEnergyActionPlans(SEAPs),withinthe
yearfollowingtheiradhesion,andthereforeshowinghowtoreachtheirCO2reductiontargetby2020.
ToassisttheCovenantsignatoriesinachievingtheirtarget,aSEAPtemplatehasbeendevelopedbythe
Covenant of Mayors Office in close collaboration with the Joint Research Centre of the European
Commission.This
user
friendly
document
must
be
completed
on
line
in
English
by
the
Covenant
signatoriesthemselvesatthesametimewhensubmittingtheirSustainableEnergyActionPlan intheir
own(national)language.Thetemplateincludesthreemainpartsdedicatedto:
Longtermvisionandoverallstrategy specifyingtheoverallCO2emissiontargetforeseen, thepriorityareasofaction,theattributionofstaffandfinancialcapacities;
Key results of the Baseline Emission Inventory indicating the current level of energyconsumptionandidentifyingtheprincipalsourcesofCO2emissions;
Key elements of the Sustainable Energy Action Plan defining the short and long termmeasures set up toput the overall strategy into action, together with timeframes, assignedresponsibilitiesandallocatedbudgets.
TheSEAPtemplateshouldhelptheCovenantsignatoriestostructuretheiractionsandmeasures,andto
follow up implementation. At the same time the template is a valuable tool for collecting key
information from the SEAPs, and thus allowing exchange of experience. Highlights of the collected
informationwillbeshownonlineattheCovenantofMayorswebsite.
In addition to this instruction document, overall guidelines are being developed, providing more
detailed information and recommendations on how to develop and prepare the Baseline Emission
InventoryandtheSEAP.
OVERALLSTRATEGY
1.OverallCO2reductiontarget
What is theoverallCO2 reduction targetofyour localauthority?PleasenotethatyourCO2 reduction
targetshouldbeatleast20%by2020asrequiredbytheCovenantofMayors.
Inprinciple, the reduction targetshouldbesetasanabsolutevalue (percentageofquantityofCO2
emissionscalculatedforthebaselineyear).Alternatively,thetargetmaybeset"percapita".Inthiscase,
the
emissions
of
the
baseline
year
are
divided
by
the
number
of
inhabitants
in
the
same
year,
and
the
percentage emission reduction target is calculated on that basis. Please tick the box of the option
chosen.
INSTRUCTIONS:
HowtofillintheSustainableEnergyActionPlantemplate?
-
7/31/2019 Template Instructions En
2/8
2.Longtermvisionofyourlocalauthority(maximum1500characters)
Pleasedefineherethelongtermvisionofyourlocalauthorityuntil2020(atleast)andmention:
a) Priorityareasofaction.InwhichsectorsyouexpecttomakethelargestCO2reductions?Whichareyourkeyactions?
b)Which
are
the
main
trends
in
terms
or
CO2
Emissions
in
your
territory/local
authority?
And
wheredothebiggestchallengeslie?
3.Organisationalandfinancialaspects(maximum500characterspercell)a) Coordination and organisational structures created/assigned: Please define the specific
structuresyourlocalauthorityhascreatedtoimplementtheCovenantofMayorsinitiative.
b) Staffcapacityallocated:Pleasedefinehowmanypeopleareworking(incorrespondingfulltimejobs)withthepreparationandimplementationofyourSustainableEnergyActionPlan.
c) Involvement of stakeholders and citizens: The Covenant of Mayors signatories commit tomobilisingthecivilsocietywithintheirareatoparticipateindevelopingtheactionplan.Please
specify:Howdidyouengagethecitizensandthedifferentstakeholdergroupsinthepreparation
ofthe
action
plan?
How
do
you
plan
to
involve
them
during
implementation?
d) Overall estimated budget: Please specify here your overall budget related to both thedevelopment and implementation of your overall strategy (including the time frame of the
estimatedbudget).
e) Foreseenfinancing sourcesfor the investments within your actionplan: Please indicate themain (re)allocations in themunicipalbudgetand fromwhichexternalsources (e.g.European,
nationalorregional fundingschemes,sponsors,etc.)youareexpectingtoget funding forthe
implementationofthekeyactionswithinyouractionplan.
f) Planned measuresfor monitoring andfollow up: Please specify, how the local authority isplanningtoorganisethemonitoringandevaluationoftheactionplan.Pleasealsonotethatthe
signatories of the Covenant ofMayors will have to deliver an implementation report every
second
year.
The
first
report
is
due
two
years
after
the
submission
of
the
Sustainable
Energy
ActionPlan.
BASELINEEMISSIONINVENTORY
Themost importantprecondition for the establishmentof the Sustainable EnergyAction Plan is the
BaselineEmissionInventory.Thetemplateisdesignedtosummarisethekeydataofyourinventory(itis
notdesignedasacalculation tool foryourCO2emissions).Within the frameworkof theCovenantof
Mayors, the Baseline Emissions Inventory as well as the SEAP should be based on final energy
consumption.
1.Baselineyear
Therecommendedbaselineyearofthe inventory is1990. Ifthe localauthoritydoesnothavedatato
compile an inventory for 1990, then it should choose the closest year to 1990 forwhich themost
comprehensiveandreliabledatacanbecollected.
2.Choiceofemissionfactors
TheBaselineEmission Inventory shouldbebasedonactivitydata (the finalenergy consumption that
occurs
within
the
territory
of
the
local
authority)
and
emission
factors,
which
quantify
the
emissions
per
unitofactivity.Twodifferentapproachesmaybefollowedwhenselectingtheemissionfactors:
-
7/31/2019 Template Instructions En
3/8
1. Using Standard emission factors in linewith the IPCC principles,which cover all the CO2emissions that occur due to energy consumptionwithin the territory of the local authority,
eitherdirectlyduetofuelcombustionwithinthelocalauthorityorindirectlyviafuelcombustion
associatedwithelectricityandheat/coldusagewithintheirarea.Thisapproachisbasedonthe
carboncontentofeach fuel, like innationalgreenhousegas inventories in thecontextof the
UNFCCCandtheKyotoprotocol.Inthisapproach,theCO2emissionsfromtheuseofrenewable
energy
as
well
as
emissions
of
certified
green
electricity
are
considered
to
be
zero.
Also
the
CO2
isthemostimportantgreenhousegas,andtheshareofCH4andN2Oemissionsdonotneedto
becalculated.Therefore,thelocalauthoritythatdecidestousethisapproachisaskedtoreport
itsCO2emissions (int).However,alsoothergreenhousegasescanbe included in thebaseline
inventory,andinthiscasetheemissionsarereportedasCO2equivalents.
2. UsingLCA(LifeCycleAssessment)factors,whichtakeintoconsiderationtheoveralllifecycleoftheenergycarrier.Thisapproach includesnotonlytheemissionsofthe finalcombustion,but
also allemissionsof the supply chain (such as transport losses, refineryemissionsor energy
conversionlosses)thattakeplaceoutsidetheterritory.Inthisapproach,theCO2emissionsfrom
theuseofrenewableenergyaswellasemissionsofcertifiedgreenelectricityarehigherthan
zero.Inthecaseofthisapproach,othergreenhousegasesthanCO2canplayanimportantrole.
Therefore,
the
local
authority
that
decides
to
use
LCA
approach
can
report
emissions
as
CO2
equivalent. However, if in the methodology/tool used only counts CO2 emissions, then
emissionscanbereportedasCO2(int).
Pleasetickthecorrespondingboxtotheemissionfactorapproachyouhavechosen(IPCC/LCA).
PleasealsochoosewhethertheemissionsarereportedinCO2orCO2equivalentemissions.
3.KeyresultsoftheBaselineEmissionInventory
Thissectionisdividedintofourtables:
A. FinalenergyconsumptionB.
CO2
or
CO2
equivalent
emissions
C. LocalelectricityproductionandcorrespondingCO2orCO2equivalentemissionsD. Localdistrictheating/cooling,CHPandcorrespondingCO2 andCO2equivalentemissions
TableA.Finalenergyconsumption
Thistablesummarizestheessentialdataofyourfinalenergyconsumption,i.e.theamountofelectricity,
heat/cold,fossilfuelsandrenewableenergyconsumedbythefinalendusers.
Category
Thiscolumnreferstothesectorsthatconsumeenergy/emitCO2.Thesectorsaresplit intotwomain
categories Buildings, equipment/facilities and industries and Transport and eight subcategories.
Filling
the
data
for
these
categories
is
mandatory.
In
detail:
1Buildings,equipment/facilitiesandindustry
Thiscategorycoversallbuildings,services,facilitiesandindustrialpremises.Ifpossible,thedatashould
besplitintothefollowingfivesubcategories:
"Municipal buildings and equipment/facilities: the term "equipment/facilities" covers energyconsuming entities that are not buildings (e.g.water treatment units, recycling centres and
composting plants). Residential buildings owned by the local authority or an affiliated
organisationhavetobeincludedinthesubcategoryResidentialbuildings
"Tertiary (nonmunicipal)buildings,equipment/facilities"referstoallbuildingsandfacilitiesofthetertiarysector(servicessector)thatarenotownedormanagedbythe localauthority(e.g.
offices
of
private
companies,
banks,
SME's,
commercial
and
retail
activities,
hospitals
etc.)
"Residentialbuildings":energyconsumption inbuildings thatareprimarilyusedas residentialbuildings
-
7/31/2019 Template Instructions En
4/8
"Municipalpublic lighting":public lightingownedoroperatedbythe localauthority.Anynonmunicipalpubliclightingshouldbereferredinthecategory"Tertiary(nonmunicipal)buildings,
equipment/facilities".
Industry:Generally,localauthoritiesonlyhavealimitedinfluenceonindustry.Therefore,thefollowingrulesapplyfortheCovenantsignatories:
o ThelocalauthoritymaydecidetoincludethissectorintheirSEAP(notcompulsory).o TheenergyandCO2datarelatedtothissectorshouldbereportedonly ifthesector is
includedintheSEAP.
o Plants covered by the ETS (European Emission Trading Scheme) should be excluded,unlesssuchplantswereincludedinpreviousenergyplansandCO2emissioninventories
ofthelocalauthority.
o If industrial emissions are included in the Baseline Emission Inventory, and a majorindustrialcompany/plantclosesdownbetweenthebaseyearandthetargetyear2020,
itsemissionsshouldbeexcluded fromthe Inventory.CO2emissionreduction resulting
fromindustryrelocationcannotcontributetotheoverallCO2reductiontarget.
o Similarly, new industrial companies/plants constructed in the territory of your localauthoritybetween thebaseline year and 2020, do not need to be included into the
inventoriesof
future
years.
2Transport
Thiscategorycoversroadandrailtransport.Theenergyconsumptiondatashouldbebasedonactual
consumptiondata (municipal fleetorpublic transport)oronestimatesbasedon themileageon the
streetnetworkofthelocalauthority.
Ifpossible,thedatashouldbesplitintothefollowingthreesubcategories:
- Municipalfleet:Vehiclesownedandusedbythelocalauthority/administration- Publictransport:Bus,tramway,metro,urbanrailtransportation- Privateand commercial transport:Thiscategorycoversall roadand rail transport in the
territoryof
your
local
authority
not
specified
above
(e.g.
cars
and
freight
traffic)
FinalenergyconsumptioninMWh
Thesecolumns refer to thedifferentenergycommodities thatareconsumedby theenduserswithin
theterritoryofyourlocalauthorityandshouldbecompletedpercategory,ifpossiblepersubcategory:
- "Electricity"referstothetotalelectricityconsumedbyendusers,whatevertheproductionsourceis.Ifthelocalauthorityispurchasingcertifiedgreenelectricitypleasecompletealso
thecellbelowthetableaswellasthecorrespondingemissionfactor istheLCAfactorsare
used.Certifiedgreenelectricity"meanselectricityproducedfromrenewableenergysourcescovered by Guarantee of origins as per article 5 of directive 2001/77/CE, article 15 of
directive2009/28/ECandarticle3(6)ofdirective2003/54/EC.
- "Heat/cold" refers toheating/cooling that issuppliedasacommodity toenduserswithintheterritory (forexample fromdistrictheating/coolingsystem,aCHPplantorwasteheat
recovery).Heatingproducedbyendusers for theirownuse shouldnotbe includedhere,
butunderthecolumnsoftheenergycarriersthatproducetheheat.Withtheexceptionof
CHP heat: as a CHP unit also generates electricity, it is preferable to included it under
production(tablesCandD),especiallyifitconcernslargeunits.
- "Fossilfuels"coverallfossilfuelsconsumedasacommoditybyfinalendusers.Itincludesallfossil fuels bought by endusers for space heating, sanitary water heating, or cooking
purposes. It also includes fuels consumed for transportation purposes, or as an input in
industrialcombustionprocesses1.
- Renewable energiesAll plantoil,biofuel, other biomass (e.gwood), solar thermal andgeothermal
consumed
as
acommodity
by
final
end
users.
1OnlyiftheSEAPincludesactionsinthissector.However,energyuseofindustryinvolvedinEUETSisexcluded.
-
7/31/2019 Template Instructions En
5/8
Note:Peatisexcluded.Ifpeatisconsumedwithinthelocalauthority,itshouldbeaccounted
forinthe"otherfossilfuel"columnL(evenifitisnotstrictlyspeakingafossilfuel).
TableB:CO2 orCO2equivalentemissions
Thistablesummarisesthequantityofgreenhousegasesemittedasaresultoftheenergyconsumption
withinthelocalauthority.
Category
Thiscolumnreferstothesectorsemittinggreenhousegasses.Theyarethesameasthoselistedintable
A.Howeverathirdsectorhasbeenadded:
3otheremissionsources
InadditiontoemissionsourcesrelatedtoenergyconsumptionspecifiedintableA,yourlocalauthority
mayvoluntarily includeothergreenhousegasemission sources in the inventory, if theSEAP includes
actions to mitigate these emissions. For instance, the local authority can choose to include CH4
emissionsfrom landfills, ifoneoftheSEAPmeasures istobegin landfillgasrecoveryatthe landfill.To
facilitatethedatacollectionwastemanagementandwastewatermanagementhavebeenpredefined
as
possible
sectors.
Please
note
that
collecting
data
for
these
sectors
is
voluntary.
Please
indicate
only
totalemissionsinCO2equivalents.
CO2emissionsintCO2ortCO2eq
Compared to the tableof finalenergy consumption, thegreenhousegasemissionsare reported in a
similarmanner. They have to be calculated for each energy source by multiplying the final energy
consumptionbythecorrespondingemissionfactors.
IfyouhavetoincludeseveralenergycarriersinthesamecolumnoftableB(e.g.differenttypesof
electricity;orheatandcold;orseveralfossilfuelsundercolumn"otherfossilfuels"),it ispreferableto
makeseparatecalculationswiththedifferentenergycarriersandtheirrespectiveemissionfactors,and
toreportthetotalemissionsinthetable,withthecorrespondingaverageemissionfactor.
Emissionfactorsint/MWh
The IPCC provides default emission factors available from the 2006 IPCC Guidelines2. The default
emissionfactorscouldbereplacedbycountryspecificemissionfactorswhichtakeaccountofcountry
specificdata.TheCovenant signatoriescanalsodevelopownemission factorsbasedon thedetailed
propertiesofthefuelsusedwithintheirterritory.InadditionLCAfactors,whichtake intoaccountthe
lifecycleoftheenergycarrier,canbeused.
Pleasecompleteforeachenergycarriertheemissionfactoryouhaveused.
Inaddition,pleaseindicatethechosenvalueinthecell"CO2emissionfactorforelectricitynotproduced
locally[t/MWh]"belowtableB.
Thelocalemissionfactorforelectricity(EFE)shouldreflecttheenergymixusedtoproduceelectricity.
IfthelocalauthorityhasdecidedtoincludemeasuresrelatedtolocalelectricityproductionintheSEAP,
thentheEFEhastobecalculatedtofitthelocalsituation.Forthispurpose,tableChastobefilled(see
below).Ifthelocalauthoritypurchasescertifiedgreenelectricity,thentheEFEmayalsoberecalculated
toreflecttheassociatedCO2emissiongains.
Inasimilarmannerthelocalemissionfactorforheating/coolingshouldreflecttheenergymixusedto
producetheheat/coldthatisreferredintableA.
2Defaultemissionfactorsareavailableinthe2006IPCCGuidelinesVolume2,Chapter2,Table2.2.(page16).
-
7/31/2019 Template Instructions En
6/8
TheguidelinesfortheBaselineEmissionInventorywillprovidetableswithallrelevantemissionfactors
together with the formulas for calculating local emission factors for electricity and heating/cooling
basedonthedataprovidedintablesCandD(seebelow).
TableC.LocalelectricityproductionandcorrespondingCO2orCO2equivalentemissions
Although
reducing
the
final
energy
consumption
is
considered
as
a
priority
in
the
context
of
the
Covenant of Mayors, reductions of the greenhouse gas emissions in the supply side can also be
accounted for, for examplewhen the local authority acts aspromoterof renewable installations,or
carriesoutenergyefficiencymeasuresinlocaldistrictheatingplants.
Thelocalauthoritycandecidewhetherornottoincludelocalelectricityproductionintheinventoryand
SEAP. IfyourSEAP includesactions related toelectricityproductionwithin the territoryofyour local
authority(e.g.developmentofPVs,windpower,hydroelectricpoweretc.)orimprovementofefficiency
inlocalpowergeneration,pleasefillinthistable.Youshouldthenonlyincludethelocalplants/units,
i.e.plantsthatmeetthefollowingcriteria:
a) Plants/unitsarenotincludedintheEuropeanEmissionsTradingScheme(ETS),b)
Plants/units
are
below
or
equal
to
20MW
as
thermal
energy
input
in
the
case
of
fuel
combustion
plants,oroutput forrenewable (20MWcorresponds totheEUETS threshold forcombustion
installations).
However, if the localauthorityplans specificactionswithownutilities (orhas incorporated ETS
plantsinpastactionplans)orplanstodevelopandfinancelargerenewableinstallationslikewind
farms,suchprojectsmaybeincorporated,aslongasthepriorityremainsonthedemandside(final
energyconsumptionreductions).
Allplantsthatrespecttheaboverulesshouldbelisted,withcorrespondingquantityoflocallygenerated
electricity (in MWh). For combustion plants, the energy carrier inputs have to be specified. For
convenience, similarproductionunitsmaybe grouped (for example PV installationsor cogeneration
units). Please report the CO2 or CO2 equivalent emissions and specify the corresponding emission
factors.
TableD:Localdistrictheating/cooling,CHPandcorrespondingCO2 andCO2equivalentemissions
This table has to be filled in only if heat/cold (e.g. from a district heating boiler or a CHP plant) is
suppliedasa commodity toenduserswithin the territoryof the localauthority.Thepurposeof this
tableistocalculatetheCO2emissionrelatedtoheat/coldproduction.
Allplants thatgenerateheatorcold that issold/distributedasacommodity toenduserswithinthe
territoryofthelocalauthority(ingeneralviaadistrictheatingsystem)shouldbeconsideredandlisted
withthegeneratedquantityofheat/cold,theenergyinputs,andcorrespondingCO2 orCO2equivalent
emissionsandemissionfactors.Forconvenience,similarproductionunitsmaybegrouped.
PleasenotethatenergyconsumptionandCO2emissionsrelatedtoheatandcold locallyproducedby
endusers for their own usage are already covered by tables A and B (columns for fossil fuel and
renewable energy consumption).In principle, the total amount of heat/cold produced referenced in
tableDshouldbeequal(orveryclose)tothequantityofheat/coldconsumedandreportedintableA,
column"Heat/cold".
Otheremissioninventories
IfyourlocalauthorityhasmadeseveralCO2emissioninventories,theresultsoftheseinventoriescanbe
includedinthetemplateunderthissection.
-
7/31/2019 Template Instructions En
7/8
SUSTAINABLEENERGYACTIONPLAN
1.TitleofyourSustainableEnergyActionPlan
Pleasespecifythe:
- Titleofyouractionplan(forexample:Energyplan,Climateplan,Mycityin2020),- Authorityapprovingyourplan,- Dateofitsformalapproval[day/month/year].
2.KeyelementsofyourSustainableEnergyActionPlan
ThissectiongathersthebasicinformationaboutthekeyactionsofyourSustainableEnergyActionPlan.
Sectors&fieldsofaction
Energy efficiency measures, renewable energy projects and other energyrelated actions can be
introducedinvariousactivityareasof localandregionalauthorities.TheCovenantofMayorsconcerns
theaction
at
local
level
within
the
competence
of
the
local
authorities.
Hence,
Covenant
signatories
will
beexpectedtotakeactioninseveraloralloftheirpossibleroles:
- Consumerandserviceprovider;- Planner,developerandregulator;- Advisor,motivatorandamodel;- Producerandsupplier.
Therefore theproposedSEAP template is twofold; first reflecting sectors thatare taken intoaccount
within yourBaselineEmission Inventory (i.e.buildings, equipment/facilities, industries and transport,
localelectricityproductionand localdistrict/heating/cooling,CHPs).Second itshouldalsobebasedon
thoseareaswherethelocalauthorityhasaspecificroletoplay,suchas:
- Landuseplanning(planner),- Publicprocurementofproductsandservices(consumer)or- Workingwiththecitizensandstakeholders(advisor,motivator).
However, local authorities are free to choose their key fields of action. Therefore, action in all the
mentionedareasisstronglyrecommended,butnotcompulsory.
Thistable isdesignedtohelp localauthoritiestostructuretheirmainactionsandmeasures. Incasea
sector/measure isnotcoveredby thisstructureyoucanadd itunderother (e.g. incase landfillgas
recoveryisoneoftheSEAPmeasures).
Keyactions/measures
The content of your action plan should be summarized under this section. Themeasures should be
linkedtothefieldsofaction(suchasmunicipalbuildings,publictransport,PVinstallations,trainingand
educationetc.).Please includeashortdescriptionofeachmeasure.Youcan insertmore lines, incase
youwanttolistseveralkeyactionsunderthesamefieldofaction.
Weexpectyouto listtheshorttermactionswhichhavebeenapprovedbythe localauthorityandfor
whichabudgethasbeenallocated(timehorizon35years)togetherwiththemorestrategiclongterm
actionswhich
you
intent
to
implement
by
2020.
Responsibledepartment,personorcompany
Whenenteringdetailsofyouractionsandmeasures,pleasenotethatthe informationneedstobesavedaftereachsector,otherwiseyourdatawillbelost.
-
7/31/2019 Template Instructions En
8/8
Within the action plan, responsibilities will be assigned to the different departments of your local
authority. Under this section please indicate the department responsible for implementing each
measure.ThesemightbealsothirdParties,suchasutilities/ESCOsorlocalenergyagencies.
Implementation
This section indicates the start and the end timeof each action /measurewithin your action plan.
Please
indicate
the
start
and
end
year
in
order
to
differentiate
the
short/medium
term
actions
and
the
longtermmeasures.ItisimportanttosetupshorttermactionsreducingtheCO2emissionsrightaway,
andreflectthroughlongtermmeasuresuntil2020whenthe 20%CO2targetneedstobeattained.
Estimatedcostsperaction/measure
Pleasegivean indicationofthecostforthe implicationofat leasteachshort/mediumtermmeasure/
action.Thisinformationwillshowwhatactions/measuresaremostcostly,andalsohelpevaluatingthe
costsofthekeymeasuresindifferentcountries.Pleaseindicatethecostsineuros.
Expectedenergysavingpermeasure
PleaseprovideinformationoftheexpectedenergysavinginMWhforeachmeasure.
Expectedrenewableenergyproductionpermeasure
Pleaseprovide information iftheplannedmeasure increases theshareof locallyproducedrenewable
energy(inMWh).
ExpectedCO2 orCO2equivalentemissionreductionpermeasure
Pleaseprovide informationoftheexpectedCO2emissionorCO2equivalentreduction intonsperyear
(t/a)ofeachofyourkeymeasures.
Energysavingtargetpersector
Pleasespecifytheenergysavingtargetperfieldofaction,(e.g.theenergysavingsinpublicbuildingsand
forbuildingsequipment).Pleasegiveone figure inMWhper sector.This figure should represent the
energysavingsyouaretargetingfortheyear2020comparedtoyourbaselineyear.
Itwillbecertainlydifficulttosetquantifiedenergysavingforsomeofthesectorssuchasthelanduse
planningor workingwith stakeholders.However, if there are anyestimates available,please also
indicatethese inthetable. Thiswillhelpto identifythekeyareaswhereCO2emissionreductionsare
expected.
Localrenewableenergyproductiontargetpersector
Pleasespecifythelocalrenewableenergyproductiontarget(inMWh)persectorwhenapplicable.This
figure shouldestimate the amountof locallyproduced renewable energy in 2020 compared to your
baselineyear.
Please include here only the energy locally produced/generated via renewable sources (e.g. PV
installations).Pleasealsonotethatnew installationsreduceCO2emissionsonly iftheyreplaceenergy
currentlyimportedandusedwithintheterritoryofthelocalauthority.
CO2 orCO2equivalentreductiontargetpersector
PleasespecifytheCO2 orCO2equivalentreductiontargetpersectorasfortheenergysavings.Figures
havetobegivenintones(t).Pleasenotethatfiguresforseveralsectorsaremandatory(greencells).If
noreductionisforeseenwithinthecorrespondingsectors,pleaseinsertzero.
Formore information,pleasevisitour setofFrequentlyAsked
Questions (FAQs) or download theGuidelines available in the
library! Covenant of Mayors website: www.eumayors.eu