Template Instructions En

download Template Instructions En

of 8

Transcript of Template Instructions En

  • 7/31/2019 Template Instructions En

    1/8

    Introduction

    AllCovenantsignatoriescommittosubmittingtheirSustainableEnergyActionPlans(SEAPs),withinthe

    yearfollowingtheiradhesion,andthereforeshowinghowtoreachtheirCO2reductiontargetby2020.

    ToassisttheCovenantsignatoriesinachievingtheirtarget,aSEAPtemplatehasbeendevelopedbythe

    Covenant of Mayors Office in close collaboration with the Joint Research Centre of the European

    Commission.This

    user

    friendly

    document

    must

    be

    completed

    on

    line

    in

    English

    by

    the

    Covenant

    signatoriesthemselvesatthesametimewhensubmittingtheirSustainableEnergyActionPlan intheir

    own(national)language.Thetemplateincludesthreemainpartsdedicatedto:

    Longtermvisionandoverallstrategy specifyingtheoverallCO2emissiontargetforeseen, thepriorityareasofaction,theattributionofstaffandfinancialcapacities;

    Key results of the Baseline Emission Inventory indicating the current level of energyconsumptionandidentifyingtheprincipalsourcesofCO2emissions;

    Key elements of the Sustainable Energy Action Plan defining the short and long termmeasures set up toput the overall strategy into action, together with timeframes, assignedresponsibilitiesandallocatedbudgets.

    TheSEAPtemplateshouldhelptheCovenantsignatoriestostructuretheiractionsandmeasures,andto

    follow up implementation. At the same time the template is a valuable tool for collecting key

    information from the SEAPs, and thus allowing exchange of experience. Highlights of the collected

    informationwillbeshownonlineattheCovenantofMayorswebsite.

    In addition to this instruction document, overall guidelines are being developed, providing more

    detailed information and recommendations on how to develop and prepare the Baseline Emission

    InventoryandtheSEAP.

    OVERALLSTRATEGY

    1.OverallCO2reductiontarget

    What is theoverallCO2 reduction targetofyour localauthority?PleasenotethatyourCO2 reduction

    targetshouldbeatleast20%by2020asrequiredbytheCovenantofMayors.

    Inprinciple, the reduction targetshouldbesetasanabsolutevalue (percentageofquantityofCO2

    emissionscalculatedforthebaselineyear).Alternatively,thetargetmaybeset"percapita".Inthiscase,

    the

    emissions

    of

    the

    baseline

    year

    are

    divided

    by

    the

    number

    of

    inhabitants

    in

    the

    same

    year,

    and

    the

    percentage emission reduction target is calculated on that basis. Please tick the box of the option

    chosen.

    INSTRUCTIONS:

    HowtofillintheSustainableEnergyActionPlantemplate?

  • 7/31/2019 Template Instructions En

    2/8

    2.Longtermvisionofyourlocalauthority(maximum1500characters)

    Pleasedefineherethelongtermvisionofyourlocalauthorityuntil2020(atleast)andmention:

    a) Priorityareasofaction.InwhichsectorsyouexpecttomakethelargestCO2reductions?Whichareyourkeyactions?

    b)Which

    are

    the

    main

    trends

    in

    terms

    or

    CO2

    Emissions

    in

    your

    territory/local

    authority?

    And

    wheredothebiggestchallengeslie?

    3.Organisationalandfinancialaspects(maximum500characterspercell)a) Coordination and organisational structures created/assigned: Please define the specific

    structuresyourlocalauthorityhascreatedtoimplementtheCovenantofMayorsinitiative.

    b) Staffcapacityallocated:Pleasedefinehowmanypeopleareworking(incorrespondingfulltimejobs)withthepreparationandimplementationofyourSustainableEnergyActionPlan.

    c) Involvement of stakeholders and citizens: The Covenant of Mayors signatories commit tomobilisingthecivilsocietywithintheirareatoparticipateindevelopingtheactionplan.Please

    specify:Howdidyouengagethecitizensandthedifferentstakeholdergroupsinthepreparation

    ofthe

    action

    plan?

    How

    do

    you

    plan

    to

    involve

    them

    during

    implementation?

    d) Overall estimated budget: Please specify here your overall budget related to both thedevelopment and implementation of your overall strategy (including the time frame of the

    estimatedbudget).

    e) Foreseenfinancing sourcesfor the investments within your actionplan: Please indicate themain (re)allocations in themunicipalbudgetand fromwhichexternalsources (e.g.European,

    nationalorregional fundingschemes,sponsors,etc.)youareexpectingtoget funding forthe

    implementationofthekeyactionswithinyouractionplan.

    f) Planned measuresfor monitoring andfollow up: Please specify, how the local authority isplanningtoorganisethemonitoringandevaluationoftheactionplan.Pleasealsonotethatthe

    signatories of the Covenant ofMayors will have to deliver an implementation report every

    second

    year.

    The

    first

    report

    is

    due

    two

    years

    after

    the

    submission

    of

    the

    Sustainable

    Energy

    ActionPlan.

    BASELINEEMISSIONINVENTORY

    Themost importantprecondition for the establishmentof the Sustainable EnergyAction Plan is the

    BaselineEmissionInventory.Thetemplateisdesignedtosummarisethekeydataofyourinventory(itis

    notdesignedasacalculation tool foryourCO2emissions).Within the frameworkof theCovenantof

    Mayors, the Baseline Emissions Inventory as well as the SEAP should be based on final energy

    consumption.

    1.Baselineyear

    Therecommendedbaselineyearofthe inventory is1990. Ifthe localauthoritydoesnothavedatato

    compile an inventory for 1990, then it should choose the closest year to 1990 forwhich themost

    comprehensiveandreliabledatacanbecollected.

    2.Choiceofemissionfactors

    TheBaselineEmission Inventory shouldbebasedonactivitydata (the finalenergy consumption that

    occurs

    within

    the

    territory

    of

    the

    local

    authority)

    and

    emission

    factors,

    which

    quantify

    the

    emissions

    per

    unitofactivity.Twodifferentapproachesmaybefollowedwhenselectingtheemissionfactors:

  • 7/31/2019 Template Instructions En

    3/8

    1. Using Standard emission factors in linewith the IPCC principles,which cover all the CO2emissions that occur due to energy consumptionwithin the territory of the local authority,

    eitherdirectlyduetofuelcombustionwithinthelocalauthorityorindirectlyviafuelcombustion

    associatedwithelectricityandheat/coldusagewithintheirarea.Thisapproachisbasedonthe

    carboncontentofeach fuel, like innationalgreenhousegas inventories in thecontextof the

    UNFCCCandtheKyotoprotocol.Inthisapproach,theCO2emissionsfromtheuseofrenewable

    energy

    as

    well

    as

    emissions

    of

    certified

    green

    electricity

    are

    considered

    to

    be

    zero.

    Also

    the

    CO2

    isthemostimportantgreenhousegas,andtheshareofCH4andN2Oemissionsdonotneedto

    becalculated.Therefore,thelocalauthoritythatdecidestousethisapproachisaskedtoreport

    itsCO2emissions (int).However,alsoothergreenhousegasescanbe included in thebaseline

    inventory,andinthiscasetheemissionsarereportedasCO2equivalents.

    2. UsingLCA(LifeCycleAssessment)factors,whichtakeintoconsiderationtheoveralllifecycleoftheenergycarrier.Thisapproach includesnotonlytheemissionsofthe finalcombustion,but

    also allemissionsof the supply chain (such as transport losses, refineryemissionsor energy

    conversionlosses)thattakeplaceoutsidetheterritory.Inthisapproach,theCO2emissionsfrom

    theuseofrenewableenergyaswellasemissionsofcertifiedgreenelectricityarehigherthan

    zero.Inthecaseofthisapproach,othergreenhousegasesthanCO2canplayanimportantrole.

    Therefore,

    the

    local

    authority

    that

    decides

    to

    use

    LCA

    approach

    can

    report

    emissions

    as

    CO2

    equivalent. However, if in the methodology/tool used only counts CO2 emissions, then

    emissionscanbereportedasCO2(int).

    Pleasetickthecorrespondingboxtotheemissionfactorapproachyouhavechosen(IPCC/LCA).

    PleasealsochoosewhethertheemissionsarereportedinCO2orCO2equivalentemissions.

    3.KeyresultsoftheBaselineEmissionInventory

    Thissectionisdividedintofourtables:

    A. FinalenergyconsumptionB.

    CO2

    or

    CO2

    equivalent

    emissions

    C. LocalelectricityproductionandcorrespondingCO2orCO2equivalentemissionsD. Localdistrictheating/cooling,CHPandcorrespondingCO2 andCO2equivalentemissions

    TableA.Finalenergyconsumption

    Thistablesummarizestheessentialdataofyourfinalenergyconsumption,i.e.theamountofelectricity,

    heat/cold,fossilfuelsandrenewableenergyconsumedbythefinalendusers.

    Category

    Thiscolumnreferstothesectorsthatconsumeenergy/emitCO2.Thesectorsaresplit intotwomain

    categories Buildings, equipment/facilities and industries and Transport and eight subcategories.

    Filling

    the

    data

    for

    these

    categories

    is

    mandatory.

    In

    detail:

    1Buildings,equipment/facilitiesandindustry

    Thiscategorycoversallbuildings,services,facilitiesandindustrialpremises.Ifpossible,thedatashould

    besplitintothefollowingfivesubcategories:

    "Municipal buildings and equipment/facilities: the term "equipment/facilities" covers energyconsuming entities that are not buildings (e.g.water treatment units, recycling centres and

    composting plants). Residential buildings owned by the local authority or an affiliated

    organisationhavetobeincludedinthesubcategoryResidentialbuildings

    "Tertiary (nonmunicipal)buildings,equipment/facilities"referstoallbuildingsandfacilitiesofthetertiarysector(servicessector)thatarenotownedormanagedbythe localauthority(e.g.

    offices

    of

    private

    companies,

    banks,

    SME's,

    commercial

    and

    retail

    activities,

    hospitals

    etc.)

    "Residentialbuildings":energyconsumption inbuildings thatareprimarilyusedas residentialbuildings

  • 7/31/2019 Template Instructions En

    4/8

    "Municipalpublic lighting":public lightingownedoroperatedbythe localauthority.Anynonmunicipalpubliclightingshouldbereferredinthecategory"Tertiary(nonmunicipal)buildings,

    equipment/facilities".

    Industry:Generally,localauthoritiesonlyhavealimitedinfluenceonindustry.Therefore,thefollowingrulesapplyfortheCovenantsignatories:

    o ThelocalauthoritymaydecidetoincludethissectorintheirSEAP(notcompulsory).o TheenergyandCO2datarelatedtothissectorshouldbereportedonly ifthesector is

    includedintheSEAP.

    o Plants covered by the ETS (European Emission Trading Scheme) should be excluded,unlesssuchplantswereincludedinpreviousenergyplansandCO2emissioninventories

    ofthelocalauthority.

    o If industrial emissions are included in the Baseline Emission Inventory, and a majorindustrialcompany/plantclosesdownbetweenthebaseyearandthetargetyear2020,

    itsemissionsshouldbeexcluded fromthe Inventory.CO2emissionreduction resulting

    fromindustryrelocationcannotcontributetotheoverallCO2reductiontarget.

    o Similarly, new industrial companies/plants constructed in the territory of your localauthoritybetween thebaseline year and 2020, do not need to be included into the

    inventoriesof

    future

    years.

    2Transport

    Thiscategorycoversroadandrailtransport.Theenergyconsumptiondatashouldbebasedonactual

    consumptiondata (municipal fleetorpublic transport)oronestimatesbasedon themileageon the

    streetnetworkofthelocalauthority.

    Ifpossible,thedatashouldbesplitintothefollowingthreesubcategories:

    - Municipalfleet:Vehiclesownedandusedbythelocalauthority/administration- Publictransport:Bus,tramway,metro,urbanrailtransportation- Privateand commercial transport:Thiscategorycoversall roadand rail transport in the

    territoryof

    your

    local

    authority

    not

    specified

    above

    (e.g.

    cars

    and

    freight

    traffic)

    FinalenergyconsumptioninMWh

    Thesecolumns refer to thedifferentenergycommodities thatareconsumedby theenduserswithin

    theterritoryofyourlocalauthorityandshouldbecompletedpercategory,ifpossiblepersubcategory:

    - "Electricity"referstothetotalelectricityconsumedbyendusers,whatevertheproductionsourceis.Ifthelocalauthorityispurchasingcertifiedgreenelectricitypleasecompletealso

    thecellbelowthetableaswellasthecorrespondingemissionfactor istheLCAfactorsare

    used.Certifiedgreenelectricity"meanselectricityproducedfromrenewableenergysourcescovered by Guarantee of origins as per article 5 of directive 2001/77/CE, article 15 of

    directive2009/28/ECandarticle3(6)ofdirective2003/54/EC.

    - "Heat/cold" refers toheating/cooling that issuppliedasacommodity toenduserswithintheterritory (forexample fromdistrictheating/coolingsystem,aCHPplantorwasteheat

    recovery).Heatingproducedbyendusers for theirownuse shouldnotbe includedhere,

    butunderthecolumnsoftheenergycarriersthatproducetheheat.Withtheexceptionof

    CHP heat: as a CHP unit also generates electricity, it is preferable to included it under

    production(tablesCandD),especiallyifitconcernslargeunits.

    - "Fossilfuels"coverallfossilfuelsconsumedasacommoditybyfinalendusers.Itincludesallfossil fuels bought by endusers for space heating, sanitary water heating, or cooking

    purposes. It also includes fuels consumed for transportation purposes, or as an input in

    industrialcombustionprocesses1.

    - Renewable energiesAll plantoil,biofuel, other biomass (e.gwood), solar thermal andgeothermal

    consumed

    as

    acommodity

    by

    final

    end

    users.

    1OnlyiftheSEAPincludesactionsinthissector.However,energyuseofindustryinvolvedinEUETSisexcluded.

  • 7/31/2019 Template Instructions En

    5/8

    Note:Peatisexcluded.Ifpeatisconsumedwithinthelocalauthority,itshouldbeaccounted

    forinthe"otherfossilfuel"columnL(evenifitisnotstrictlyspeakingafossilfuel).

    TableB:CO2 orCO2equivalentemissions

    Thistablesummarisesthequantityofgreenhousegasesemittedasaresultoftheenergyconsumption

    withinthelocalauthority.

    Category

    Thiscolumnreferstothesectorsemittinggreenhousegasses.Theyarethesameasthoselistedintable

    A.Howeverathirdsectorhasbeenadded:

    3otheremissionsources

    InadditiontoemissionsourcesrelatedtoenergyconsumptionspecifiedintableA,yourlocalauthority

    mayvoluntarily includeothergreenhousegasemission sources in the inventory, if theSEAP includes

    actions to mitigate these emissions. For instance, the local authority can choose to include CH4

    emissionsfrom landfills, ifoneoftheSEAPmeasures istobegin landfillgasrecoveryatthe landfill.To

    facilitatethedatacollectionwastemanagementandwastewatermanagementhavebeenpredefined

    as

    possible

    sectors.

    Please

    note

    that

    collecting

    data

    for

    these

    sectors

    is

    voluntary.

    Please

    indicate

    only

    totalemissionsinCO2equivalents.

    CO2emissionsintCO2ortCO2eq

    Compared to the tableof finalenergy consumption, thegreenhousegasemissionsare reported in a

    similarmanner. They have to be calculated for each energy source by multiplying the final energy

    consumptionbythecorrespondingemissionfactors.

    IfyouhavetoincludeseveralenergycarriersinthesamecolumnoftableB(e.g.differenttypesof

    electricity;orheatandcold;orseveralfossilfuelsundercolumn"otherfossilfuels"),it ispreferableto

    makeseparatecalculationswiththedifferentenergycarriersandtheirrespectiveemissionfactors,and

    toreportthetotalemissionsinthetable,withthecorrespondingaverageemissionfactor.

    Emissionfactorsint/MWh

    The IPCC provides default emission factors available from the 2006 IPCC Guidelines2. The default

    emissionfactorscouldbereplacedbycountryspecificemissionfactorswhichtakeaccountofcountry

    specificdata.TheCovenant signatoriescanalsodevelopownemission factorsbasedon thedetailed

    propertiesofthefuelsusedwithintheirterritory.InadditionLCAfactors,whichtake intoaccountthe

    lifecycleoftheenergycarrier,canbeused.

    Pleasecompleteforeachenergycarriertheemissionfactoryouhaveused.

    Inaddition,pleaseindicatethechosenvalueinthecell"CO2emissionfactorforelectricitynotproduced

    locally[t/MWh]"belowtableB.

    Thelocalemissionfactorforelectricity(EFE)shouldreflecttheenergymixusedtoproduceelectricity.

    IfthelocalauthorityhasdecidedtoincludemeasuresrelatedtolocalelectricityproductionintheSEAP,

    thentheEFEhastobecalculatedtofitthelocalsituation.Forthispurpose,tableChastobefilled(see

    below).Ifthelocalauthoritypurchasescertifiedgreenelectricity,thentheEFEmayalsoberecalculated

    toreflecttheassociatedCO2emissiongains.

    Inasimilarmannerthelocalemissionfactorforheating/coolingshouldreflecttheenergymixusedto

    producetheheat/coldthatisreferredintableA.

    2Defaultemissionfactorsareavailableinthe2006IPCCGuidelinesVolume2,Chapter2,Table2.2.(page16).

  • 7/31/2019 Template Instructions En

    6/8

    TheguidelinesfortheBaselineEmissionInventorywillprovidetableswithallrelevantemissionfactors

    together with the formulas for calculating local emission factors for electricity and heating/cooling

    basedonthedataprovidedintablesCandD(seebelow).

    TableC.LocalelectricityproductionandcorrespondingCO2orCO2equivalentemissions

    Although

    reducing

    the

    final

    energy

    consumption

    is

    considered

    as

    a

    priority

    in

    the

    context

    of

    the

    Covenant of Mayors, reductions of the greenhouse gas emissions in the supply side can also be

    accounted for, for examplewhen the local authority acts aspromoterof renewable installations,or

    carriesoutenergyefficiencymeasuresinlocaldistrictheatingplants.

    Thelocalauthoritycandecidewhetherornottoincludelocalelectricityproductionintheinventoryand

    SEAP. IfyourSEAP includesactions related toelectricityproductionwithin the territoryofyour local

    authority(e.g.developmentofPVs,windpower,hydroelectricpoweretc.)orimprovementofefficiency

    inlocalpowergeneration,pleasefillinthistable.Youshouldthenonlyincludethelocalplants/units,

    i.e.plantsthatmeetthefollowingcriteria:

    a) Plants/unitsarenotincludedintheEuropeanEmissionsTradingScheme(ETS),b)

    Plants/units

    are

    below

    or

    equal

    to

    20MW

    as

    thermal

    energy

    input

    in

    the

    case

    of

    fuel

    combustion

    plants,oroutput forrenewable (20MWcorresponds totheEUETS threshold forcombustion

    installations).

    However, if the localauthorityplans specificactionswithownutilities (orhas incorporated ETS

    plantsinpastactionplans)orplanstodevelopandfinancelargerenewableinstallationslikewind

    farms,suchprojectsmaybeincorporated,aslongasthepriorityremainsonthedemandside(final

    energyconsumptionreductions).

    Allplantsthatrespecttheaboverulesshouldbelisted,withcorrespondingquantityoflocallygenerated

    electricity (in MWh). For combustion plants, the energy carrier inputs have to be specified. For

    convenience, similarproductionunitsmaybe grouped (for example PV installationsor cogeneration

    units). Please report the CO2 or CO2 equivalent emissions and specify the corresponding emission

    factors.

    TableD:Localdistrictheating/cooling,CHPandcorrespondingCO2 andCO2equivalentemissions

    This table has to be filled in only if heat/cold (e.g. from a district heating boiler or a CHP plant) is

    suppliedasa commodity toenduserswithin the territoryof the localauthority.Thepurposeof this

    tableistocalculatetheCO2emissionrelatedtoheat/coldproduction.

    Allplants thatgenerateheatorcold that issold/distributedasacommodity toenduserswithinthe

    territoryofthelocalauthority(ingeneralviaadistrictheatingsystem)shouldbeconsideredandlisted

    withthegeneratedquantityofheat/cold,theenergyinputs,andcorrespondingCO2 orCO2equivalent

    emissionsandemissionfactors.Forconvenience,similarproductionunitsmaybegrouped.

    PleasenotethatenergyconsumptionandCO2emissionsrelatedtoheatandcold locallyproducedby

    endusers for their own usage are already covered by tables A and B (columns for fossil fuel and

    renewable energy consumption).In principle, the total amount of heat/cold produced referenced in

    tableDshouldbeequal(orveryclose)tothequantityofheat/coldconsumedandreportedintableA,

    column"Heat/cold".

    Otheremissioninventories

    IfyourlocalauthorityhasmadeseveralCO2emissioninventories,theresultsoftheseinventoriescanbe

    includedinthetemplateunderthissection.

  • 7/31/2019 Template Instructions En

    7/8

    SUSTAINABLEENERGYACTIONPLAN

    1.TitleofyourSustainableEnergyActionPlan

    Pleasespecifythe:

    - Titleofyouractionplan(forexample:Energyplan,Climateplan,Mycityin2020),- Authorityapprovingyourplan,- Dateofitsformalapproval[day/month/year].

    2.KeyelementsofyourSustainableEnergyActionPlan

    ThissectiongathersthebasicinformationaboutthekeyactionsofyourSustainableEnergyActionPlan.

    Sectors&fieldsofaction

    Energy efficiency measures, renewable energy projects and other energyrelated actions can be

    introducedinvariousactivityareasof localandregionalauthorities.TheCovenantofMayorsconcerns

    theaction

    at

    local

    level

    within

    the

    competence

    of

    the

    local

    authorities.

    Hence,

    Covenant

    signatories

    will

    beexpectedtotakeactioninseveraloralloftheirpossibleroles:

    - Consumerandserviceprovider;- Planner,developerandregulator;- Advisor,motivatorandamodel;- Producerandsupplier.

    Therefore theproposedSEAP template is twofold; first reflecting sectors thatare taken intoaccount

    within yourBaselineEmission Inventory (i.e.buildings, equipment/facilities, industries and transport,

    localelectricityproductionand localdistrict/heating/cooling,CHPs).Second itshouldalsobebasedon

    thoseareaswherethelocalauthorityhasaspecificroletoplay,suchas:

    - Landuseplanning(planner),- Publicprocurementofproductsandservices(consumer)or- Workingwiththecitizensandstakeholders(advisor,motivator).

    However, local authorities are free to choose their key fields of action. Therefore, action in all the

    mentionedareasisstronglyrecommended,butnotcompulsory.

    Thistable isdesignedtohelp localauthoritiestostructuretheirmainactionsandmeasures. Incasea

    sector/measure isnotcoveredby thisstructureyoucanadd itunderother (e.g. incase landfillgas

    recoveryisoneoftheSEAPmeasures).

    Keyactions/measures

    The content of your action plan should be summarized under this section. Themeasures should be

    linkedtothefieldsofaction(suchasmunicipalbuildings,publictransport,PVinstallations,trainingand

    educationetc.).Please includeashortdescriptionofeachmeasure.Youcan insertmore lines, incase

    youwanttolistseveralkeyactionsunderthesamefieldofaction.

    Weexpectyouto listtheshorttermactionswhichhavebeenapprovedbythe localauthorityandfor

    whichabudgethasbeenallocated(timehorizon35years)togetherwiththemorestrategiclongterm

    actionswhich

    you

    intent

    to

    implement

    by

    2020.

    Responsibledepartment,personorcompany

    Whenenteringdetailsofyouractionsandmeasures,pleasenotethatthe informationneedstobesavedaftereachsector,otherwiseyourdatawillbelost.

  • 7/31/2019 Template Instructions En

    8/8

    Within the action plan, responsibilities will be assigned to the different departments of your local

    authority. Under this section please indicate the department responsible for implementing each

    measure.ThesemightbealsothirdParties,suchasutilities/ESCOsorlocalenergyagencies.

    Implementation

    This section indicates the start and the end timeof each action /measurewithin your action plan.

    Please

    indicate

    the

    start

    and

    end

    year

    in

    order

    to

    differentiate

    the

    short/medium

    term

    actions

    and

    the

    longtermmeasures.ItisimportanttosetupshorttermactionsreducingtheCO2emissionsrightaway,

    andreflectthroughlongtermmeasuresuntil2020whenthe 20%CO2targetneedstobeattained.

    Estimatedcostsperaction/measure

    Pleasegivean indicationofthecostforthe implicationofat leasteachshort/mediumtermmeasure/

    action.Thisinformationwillshowwhatactions/measuresaremostcostly,andalsohelpevaluatingthe

    costsofthekeymeasuresindifferentcountries.Pleaseindicatethecostsineuros.

    Expectedenergysavingpermeasure

    PleaseprovideinformationoftheexpectedenergysavinginMWhforeachmeasure.

    Expectedrenewableenergyproductionpermeasure

    Pleaseprovide information iftheplannedmeasure increases theshareof locallyproducedrenewable

    energy(inMWh).

    ExpectedCO2 orCO2equivalentemissionreductionpermeasure

    Pleaseprovide informationoftheexpectedCO2emissionorCO2equivalentreduction intonsperyear

    (t/a)ofeachofyourkeymeasures.

    Energysavingtargetpersector

    Pleasespecifytheenergysavingtargetperfieldofaction,(e.g.theenergysavingsinpublicbuildingsand

    forbuildingsequipment).Pleasegiveone figure inMWhper sector.This figure should represent the

    energysavingsyouaretargetingfortheyear2020comparedtoyourbaselineyear.

    Itwillbecertainlydifficulttosetquantifiedenergysavingforsomeofthesectorssuchasthelanduse

    planningor workingwith stakeholders.However, if there are anyestimates available,please also

    indicatethese inthetable. Thiswillhelpto identifythekeyareaswhereCO2emissionreductionsare

    expected.

    Localrenewableenergyproductiontargetpersector

    Pleasespecifythelocalrenewableenergyproductiontarget(inMWh)persectorwhenapplicable.This

    figure shouldestimate the amountof locallyproduced renewable energy in 2020 compared to your

    baselineyear.

    Please include here only the energy locally produced/generated via renewable sources (e.g. PV

    installations).Pleasealsonotethatnew installationsreduceCO2emissionsonly iftheyreplaceenergy

    currentlyimportedandusedwithintheterritoryofthelocalauthority.

    CO2 orCO2equivalentreductiontargetpersector

    PleasespecifytheCO2 orCO2equivalentreductiontargetpersectorasfortheenergysavings.Figures

    havetobegivenintones(t).Pleasenotethatfiguresforseveralsectorsaremandatory(greencells).If

    noreductionisforeseenwithinthecorrespondingsectors,pleaseinsertzero.

    Formore information,pleasevisitour setofFrequentlyAsked

    Questions (FAQs) or download theGuidelines available in the

    library! Covenant of Mayors website: www.eumayors.eu