Telecom Power SolutionsTelecom power systems secure telecommunication services in case of grid power interruptions and fluctuations. Delta’s power systems are designed for wireless broadband access and fixed-line applications, as well as for Internet backbone and data centres. We provide a broad range of power systems and global services to telecom operators, network manufacturers and integrators.
Indoor Power Systems
Our InD systems fall into three categories according to size. The flexible CellD and CabD standard platforms meet most needs. However, should you need a custom solution with a unique architecture, we will come up with one – to your exact specifications.
Outdoor Power Systems
Available in different configurations, Delta OutD cabinets are designed to protect equipment from external threats in all climates from the tropics to the arctic.
Renewable Hybrid
Renewables play a significant role in Delta’s product portfolio and R&D activities. RenE is Delta’s hybrid renewable solution featuring a modular power supply concept. RenE solutions use renewable energy or a combination of renewable and other energy.
Rectifiers
A rectifier converts alternating current (AC) to direct current (DC) and provides the power necessary to charge batteries. With a focus on continuously improving the total cost of ownership, Delta’s rectifiers, combined with advanced control and monitoring.
Converters
Delta DC to DC converters are designed to provide reliable backup power for equipment with supply voltages different from that of the main battery backup system. Delta’s DC converters complement our InD and OutD systems to produce total site power.
Chargers
The solar charger adapts the output from the solar panels to the telecom battery system. The built-in maximum power tracker control ensures that the maximum solar power available is processed in the optimal manner into the battery system.
Inverters
Delta’s inverters and static switches, combined with our DC power systems, provide a modular UPS for AC power backup.
Controllers
A power system controller monitors and controls the entire system and site power infrastructure, maximizes battery life, supports energy saving, and informs the operator of maintenance needs.
1. AC-DC Rectifiers (DPR) ModulesDPR 850-48 DPR 2900-48 DPR 2900-48 DPR 3000-48 DPR 4000-48 DPR 6000-48
Power output 850 W 2900 W 2900 W 3000 W 4000 W 6000 W
Efficiency 95,2% 96,4% 97,2% 98,0% 95,2% 96,5%
Power density 30 W / in3 36,5 W / in3 36,5 W / in3 56,8 W / in3 27,3 W / in3 26,5 W / in3
Control and monitoring ORION , ORION eco, ORION c
Hot-pluggable Yes
Dimensions (W x H x D)
51,8 x 40 x 247,2 mm
125,5 x 41x 269,9 mm
125,5 x 41x 269,9 mm
84,0 x 41 x 270 mm
82 x 86,9 x 377,9 mm
129,5 x 83 x 380,7 mm
Weight 0.6 kg 2 kg 2 kg 1,4 kg 3,5 kg 5,2 kg
Cooling Fan cooled with speed control
Safety EN / IEC 60950; UL 60950; CAN / CSA – C22.2
ECO
Orion Controller Rectifiers Solid rails
Load Breakers (Max. 12xMGCB (30A)
Top Cover (Optional)
Battery Breakers. Max. 2x MHCB (100A)
CellD 20 CellD 40 CellD 100 CellD 125 (EVO)
DPS 850B-48-2 DPS 850B-48-3 DPS 850B-48-6 DPS 2900B-48-3 DPS 2900B-48-3
Rectifier module DPR 850B-48 (max. 2 pcs.)
DPR 850B-48 (max. 3 pcs.)
DPR 850B-48 (max. 6 pcs.)
DPR 2900B-48 (max. 3 pcs.)
DPR 2900B-48 (max. 3 pcs.)
Efficiency 95,2% 95,2% 95,2% 96,4% or 97,2% 96,4% or 97,2%
Install power (max. config.) 1,7 kW 2.55 kW 5.1 kW 8.7 kW 8.7 kW
Dimensions H x W x D
43.6 (1U) x 484.3 (19’) x
280 mm
43.6 (1U) x 484.3 (19’) x
280 mm
86.8 (2U) x 484.3 (19’) x
295 mm
86.8 (2U) x 484.3 (19’) x
323 mm
133.5 (3U) x 481.5 (19’) x
329 mm
Weight 4 kg 4,1 kg 7,0 kg 7,0 kg 15 kg
Input voltage range 1 P+N / 3 P+N - 80 - 300 VRMS
Max. output current / max. installed power 26 A / 1,7 kW 40 A / 2,55 kW 100 A / 5,1 kW 100 A / 8,7 kW 125 A / 8,7 kW
Controller ORION
Local interface Display, keypad, LEDs
CellD 300 (EVO2)
DPS 2900B-48-3 19IN-5U
DPS 2900B-48-5 19IN-5U
DPS 2900B-48-6 19IN-6U
DPS 2900B-48-3 21IN-4U
DPS 2900B-48-6 21IN-5U
Rectifier module DPR 2900B-48 (max. 3 pcs.)
DPR 2900B-48 (max. 5 pcs.)
DPR 2900B-48(max. 6 pcs.)
DPR 2900B-48 (max. 3 pcs.)
DPR 2900B-48 (max. 6 pcs.)
Efficiency 96,4% or 97,2%
Install power (max. config.) 8,7 kW 14,5 kW 17,4 kW 8,7 kW 8,7 kW
Dimensions H x W x D
222 (5U) x 479,7 (19’) x 315 mm
222 (5U) x 479,7 (19’)
x 315 mm
266 (6U) x 479,7 (19’)
x 315 mm
177 (4U) x 534 (21’)
x 315 mm
222 (5U) x 534 (21’) x 315 mm
Weight 13 kg 14 kg 14 kg 13 kg 14 kg
Input voltage range 3 P+N - 80 - 300 VRMS
Max. output current / max. installed power 250 A / 8,7 kW 250 A / 14,5 kW 250 A / 17,4 kW 250 A / 8,7 kW 250 A / 17,4 kW
Controller ORION
Local interface Display, keypad, LEDs
CellD 600
DPS 2900B-48-12 19IN-9U DPS 4000B-48-5 19IN-7U
Rectifier module DPR 2900B-48 (max. 12 pcs.) DPR 4000B-48 (max. 5 pcs.)
Efficiency 96,4% or 97,2% 95,2%
Install power (max. config.) 34,8 kW 20 kW
Dimensions H x W x D 399 (9U) x 480 (19’) x 375 mm 311 (7U) x 480 (19’) x 465 mm
Weight 30 kg 25 kg
Input voltage range 3 P+N - 80 - 300 VRMS
Max. output current / max. installed power 600 A / 34,8 kW 600 A / 20 kW
Controller ORION
Local interface Display, keypad, LEDs
19” Indoor Support CabinetsSite Support cabinets Wall Box
SC600 SC770 SC1300 SC1800 SC2000 WB 5U WB 8U WB 12U
Internal space 12 U 15 U 27 U 38 U 42 U 5 U / 19‘ 8 U / 19‘ 12 U / 19‘
Height 620 mm 759 mm 1295 mm 1790 mm 1961 mm 253 mm 387 mm 564 mm
Width 600 mm 548 mm
Depth 450 or 600 mm 475 mm
AC and/or DC Panel
DPD/APD/DAPD 19IN-3U DPD /APD/DAPD 21IN-3U
Operating voltage / Current (max.)
AC: 230 / 400 V (1 or 3 ph) / Related to equipmentDC: 20-60 V / 300 A
Internal space 24 modules (18 mm) 27 modules (18 mm)
Dimensions H x W x D 133 (3U) x 480 (19’) x 190 mm 133 (3U) x 530 (21’) x 190 mm
Orion Controller
Enhanced functions, such as efficiency mode and genset fuel saving, enable operating cost reductions. Battery management with capacity test and lifetime prediction and enhanced rectifier functions including redundancy supervision make it easy to monitor system availability and plan site visits in cost effective manner. Remote monitoring and alarming, and consequent cost savings are ensured with potential-free relay contacts and modem or LAN/Ethernet, SMS, SNMP or Modbus. An integrated web server offers a user-friendly interface with a standard browser both for local and remote communication.
ORION ID:E1
Mains voltage 18 - 60 VDC
Current 0.8ADC (Max.)
Protection / Switch Internal fuse 2A / None
Integrated WEB server
Remote monitoring
Advanced battery management
Enable automatic backup
Configurable extension distribution units for AC-DC components
DC-AC Inverter Rack SystemsPower backup with inverters and static switchesDelta’s inverters and static switches, combined with our DC power systems, provide a modular UPS for AC power backup. During normal operation, the system can operate in economy mode in which the energy efficiency of the total installation can be optimized. In regions with AC utility challenges, the inverter system protects the auxiliary AC-powered infrastructure from AC mains fluctuations. In addition, the inverter system offers new opportunities for energy savings by providing backup AC power.
APS 750B-230-8 19IN
APS 1500B-230-8 19IN
APS 2500B-230-8 19IN
APS 2500B-230-24 CabD
Inverter modules(Max. configuration)
8x TSI NOVA - 230Vac8x TSI MEDIA -
230Vac8x TSI BRAVO -
230Vac24x TSI BRAVO -
230Vac
Max. installed power
6 kVA / 4,2 kW 12 kVA / 9,6 kW 20 kVA / 16 kW 60 kVA / 48 kW
AC configurationInput / Output
One phase / One phase One phase / One phase orThree phases / three
phases
Inverter ModulesNova 750VA Inverter
Large CabD Inverter Configurations
CabD APS 1500A-230-20 CabD APS 1500A-230-20 SSW APS 2500B-230-24 CabD
DC Voltage range 40 – 72 VDC Inverter modules 24x TSI BRAVO – 230Vac
Nominal current 20 x 35 ADC Max. installed power 60 kVA / 48 kW
Maximum current (5 s) 20 x 50 ADC Efficiency (EPC mode) 96 %
Terminal35 mm2 or higher AC configuration Input /
Output
One phase / One phase or Three phases / three
phases
Feeding fuse (external) Based on cabling Manual Bypass T2S – ORION
Media 1.5kVA Inverter Bravo 2.5kVA Inverter
AC output breaker included10A for Pack 20, 30 / 20A for Pack 25, 35, 40, 50, 60
AC input range / Power factor 150VAC to 265VAC >0,99
750VA Modular Inverter
230Vac 120Vac
AC input range 150VAC – 265VAC 83-140Vac
Nominal output power/ current
nx1500VA / nx6,6A
nx1500VA / nx12,5A
1500VA Modular Inverter
Nominal output power / current
nx2500VA / nx10,9A (n = number of modules)
AC input range 150VAC – 265VAC
2500VA Modular Inverter
DC-DC ConvertersDC to DC converter, converting between the voltage level of battery systems to the voltage requirement of equipment. The modular format enables easy integration into the standard shelf solutions of existing DC power systems for producing a multi-voltage power solution.
CPC 1500BThe converter family provides options for converting −48V to +24V and +24V to −48V.
Input voltage range CPC 1500B-48: 19 – 30 VCPC 1500B-24: 38 – 60 V
Output voltage, nominal CPC 1500B-48: 54 VCPC 1500B-24: 27 V
Output voltage, setting range CPC 1500B-48: 48 – 56 VCPC 1500B-24: 24 – 28 V
Maximum power 1500 W
Maximum current CPC 1500B-48: 29 ACPC 1500B-24: 58 A
Control and monitoring Orion
CPC 1500B Modules
CPS 1500B
Orion Controller
Energy saving – ultra high efficiency
Delta Solar add-on kits are an ideal solution for enhancing existing on-grid and off-grid powered system installations. The usage of free renewable solar energy provides a strategic way to reduce total contractual energy bill/consumption and CO2 emissions of your telecommunication sites, enabling significant large-scale savings on energy costs and reducing the carbon footprint of your network during its operational lifetime.
PV Solutions
DC-DC Rack
PVS 2200B-48-1
Delta Solar add-on kits are an ideal solution for enhancing existing On-grid and off-grid powered system installations. The usage of free renewable solar energy provides a strategic way to reduce total contractual energy bill/consumption and CO2 emissions of your telecommunication sites, enabling significant large-scale savings on energy costs and reducing thecarbon footprint of your network during its operational lifetime.
PVS 2200B-48-3
Solar modules 1 x PVC 2200B-48
MTTP efficiency > 99,5 %
Peak power 2,2 kW
Current limitation 46 A
Voltage range 42 – 58 V
Efficiency 96 %
Solar modules 3 x PVC 2200B-48
MTTP efficiency > 99,5 %
Peak power 6,6 kW
Current limitation 138 A
Voltage range 42 – 58 V
Efficiency 96 %
PVS 2200B-48-6
Solar modules 6 x PVC 2200B-48
MTTP efficiency > 99,5 %
Peak power 13,2 kW
Current limitation 276 A
Voltage range 42 – 58 V
Efficiency 96 %
PV Charger Shelf Easy to install,
operate & maintain
• Standard shelf concept• 4 slots for 23in standard• 3 slots for 19in standard• Space savings• 1U shelf height• integrable into 400mm deep cabinets• Easy to install• All connections easy accessible at the rear• Easy to operate & maintain• Hot plug concept
ORION CONNECTION ACCESSORIESSENSN Module Shunt Measurement Temperature Measurement Battery/Load Fuse Supervision
IMBUS Repeater Modules
GWM MODBUSString Sensor Module
ALARM MODULE
PWM Modules for fan control
String Measurement Module
Solar 48V Power Rack Systems
Photovoltaic charger PVC module 2200B-48The PVC 2200B is a photovoltaic battery charger for telecommunication systems, converting solar energy to -48V telecom power systems. The flexible design supports application in standalone applications or hybrid power applications in cooperation genset supply, AC grid, wind energy or fuel cell supply.
Input
Mains voltage (full power) 250 – 350 V
Mains voltage 50 – 350 V
Current 10 A
EMI (conducted) EN 55022, class A
Protection Internal fuse
Output
Nominal system voltage -48 V
Peak power 2200 W
Current limitation 46.0 A
Over voltage protection 59.0 V
EMI (conducted) EN 55022, class A
Protection Internal fuse
PC / Network Management Sytem Communication Protocols
Webinterface: Configuration REST: Monitoring / ConfigurationSNMP: MonitoringMODBUS Slave: MonitoringTPE(V): Telephonica ProtocolTOC: Tower Operating Control Protocol (India) Commands and Alarms over SMSSYSLOG: Remote Logging
Orion PN: TPS10200023A TPS1060025A (Backplane)
Additional Interfaces6 Relais4 Digital Inputs1 LVD Driver Output4 Inputs for Middle Point Measurement3 Shunt Measurement with Fuse Supervision
ModemGPRS ANALOGUEGSM
RS232 to RS485 Converter Board
RS232-RS485 CONV PN: TPS1070026A
RELAIS
Low Voltage Disconnector LVD1 PN: D0104420
Sensor Module SENSN
PN: D0100406
String Sensor Module SSM PN: D0100982
SENSN BUS
IMB
US
(C
AN
)
Open Collector
Temp. Sensor Adapter board TEMPABO PN: TPS1070002A
PT-100 Adapter PN: TPS1070004A
LVD2 PN: TPS1070001A
User Interface Module UIM PN: TPS1070005A
Pulse with Modulation Control PWM-CTRL PN: TPS1070012A DC/DC Module
CPC 1500-B24 CPC 1500-B48
Photovoltaic Charger PVC 2200B
RS
23
2Et
her
net
18
VD
C.7
5V
DC
CabD is Delta’s robust indoor cabinet developed for telecom power systems.
CabD - Indoor Cabinets
CabD 600 CabD 1000 CabD 1500 CabD 2000
Standalone / Multicabinet Standalone Cabinet Multicabinet
(Parallel option)Multicabinet
(Parallel option)Multicabinet
(Parallel option)
Rectifier module DPR 6000 (max. 8 pcs), DPR 4000 (max.12 pcs), DPR 2900 (max.12 pcs)
DPR 6000 (max. 12 pcs)DPR 4000 (max. 18 pcs), DPR 2900 (max. 24 pcs)
DPR 6000 (max. 16 pcs),DPR 4000 (max. 24 pcs),DPR 2900 (max. 28 pcs)
DPR 6000 ( max 20 pcs)DPR 4000 (max. 30 pcs),
Max. output current /max. installed power 600 A / 34,8 kW 1000 A / 72 Kw 1500 A / 96 kW 2000 A / 120 kW
Efficiency 95,2% ... 97,2%
AC configuration 3L+N+PE or 3L+PE
Load and battery connection
Configurable – modular design
Controlling and monitoring
ORION
Operating temperature -5 - +45 °C
CabD 3000 CabD 3000+
Standalone / Multicabinet Standalone Cabinet Multicabinet
(Parallel option)
Rectifier module DPR 6000 (max. 24 pcs), DPR 4000 (max.36 pcs)
DPR 6000 (max. 24 pcs), DPR 4000 (max.36 pcs)
Max. output current /max. installed power 3000 A / 144 Kw 3000 A / 144 kW (scaled
up horizontal DC bus bars)
Efficiency 95,2% ... 96,5 %
AC configuration 3L+N+PE or 3L+PE
Load and battery connection
Configurable – modular design
Controlling and monitoring
ORION
Operating temperature -5 - +45 °C
CabD Systems – Options (Example)
Controller shelf 1U
Battery fuse TPS2up to 4x 1600 A
Battery fuse EFEN NH3 up to 4x 630 A
Battery fuse EFEN NH2 up to 4x 400 A
DPD 8x EFEN NH002..160 A
DPD 7x NH02100..400 A
DPD 30x MCB2..63 A
DPD 13x 22x582..100 A
CabD Systems – Options (Example)
OutD: M series – Flexible & Modular OutD M Series
Key advantages
Single or Multilayer wall design
-7dB(A) (lower than standard cabinets with the same cooling capacity)
Flexible configuration - 19’ or 21’ racks, battery shelves, multiple PSU options (power supply systems), multiple cable management options
Battery box extension (battery cooler)
IP20 equipment extensionSide by side connection
available
Dimensions
OutD 1,5M H1500 x W770 x D852mm - 28HU
OutD 1,8M H1829 x W770 x D852mm - 35HU
OutD 2,0M H2052 x W870 x D952mm - 40HU
Material
Steel or Aluminium, Single or multilayer with optional thermal insulation
LifetimeSteel : up to 15 year, Aluminium: up to 20 years
OutD M Series
Key advantages
Single or Multilayer wall design
-7dB(A) (lower than standard cabinets with the same cooling capacity)
Steel or aluminium outside walls
Flexible configuration - 19’ or 21’ racks, battery shelves, multiple PSU options (power supply systems), multiple cable management options
Multiple cooling options (AV, AC, Hybrid AC+AC)
Battery cooler (Separated battery compartment with advanced thermal insulation 40mm EPS and active cooling (TEC or AC)
Dimensions
OutD 0,7V H701 x W605 x D530mm - 12HU (plinth
H100mm excl.)OutD 1,2V H1257 x W708 x
D752mm - 21HUOutD 1,8V H1860 x W708 x
D752mm - 35HUOutD 2,0V H2047 x W808 x
D852mm - 39HUOutD 2,2V H2247 x W808 x
D852mm - 44HU
Material
Steel or Aluminium, Single or multilayer with optional thermal insulation
LifetimeSteel : up to 15 year, Aluminium: up to 20 years
OutD: V series Cost Effective Solution
Flexible configuration19’ or 21’ racksBattery shelves,Different PSU (power supply systems)Different cable management options
7 dB(A) lower noise compared to standard cabinets with the same cooling capacity (220 W/K)
Battery Box Extension (Battery Cooler)
Single or Multilayer wall design
Different cooling(AV, AC, Hybrid AV+AC
Cost effective solution
Battery Box Extension (Battery Cooler)
IP20 equipment extension
- 7 dB(A) lower noise compared to standard cabinets with the same cooling capacity (220 W/K)
Assembling on the siteFlat packing
Side by side connection
Small Cell Design – BoxDDimensions H684 x W489 x D312mm
EN 60529 class up to IP55
Material Enclosure: AluminiumInternal Parts: Galvanized steel
Wall structure Single layer with sun radiation screen
Lifetime Steel: 10+ years
Mounting Wall / Pole
Battery supervisionNoneLVD onlyORION + Shunt/LVD
Battery backup19” space
- 14Ah 24Ah2.5U 1U -
Options Service LED light, Alarm terminals
Cooling device
Free space for telecom equipment (19 IN rack)
PSU
Battery (2x 12 Ah)
Cable glands(Inputs / Outputs)
19” Space for battery/user equipment (total 2.5U)
ORION controller (optional)Fuses for internal circuitry
2 x 850W rectifiers
DC breakers: 1 Battery + 2 Loads
DC connection: 1 Battery + 2 LoadsAC input connection
Small Cell Power – DPR 1000B-48
Dimensions H360 x W209,8 x D88,8mm
EN 60529 class IP65
Material Aluminium
Weight 6,4kg
User Interface Status Indication
Mounting Lamppost, pole or wall mountable
PSU Power 1000W / 42 - 58Vdc
ConnectorsAC input: Amphenol PWC-03RMMS-LC7002 x 1 Dc output: Amphenol PWC-03RMFS-LC7002 x 2 Alarms: Amphenol CD-09RMFS-LC7001 x 1
Options Service LED light, Alarm terminals
Small Cell – Outdoor Rectifier Single Phase Rectifier, the rectifier requires a nominal input of 100VAC – 240VAC and provides an output of -54 VDC to power a load of communication equipment.
• For next generation 4G LTE small cell networks• OPEX energy savings – high efficiency up to
96.0%• 1000W – 48V integrated enclosure• Natural convection cooling• Light and compact size
• Wall mount or pole mount design• IP65 protection class• NEBS GR-63 Zone4, Earthquake
compliance• Optional battery back-up cabinet
enhanced surge protection and DC output distribution
The Delta BoxD is the choice where space is scarce or site density needs to be increased cost-eficiency
IP65
R, RT
EH
HPHNH Plus
DPH
NT
DPS
1-10kVA Rack/Computer
Room
10-20kVA Small Data
Center
20-120kVA 20-120kVA Medium Data
Center
25-200kVA 25-500kVA 25-500kVALarge Data
Center
Delta provides a full range of UPS’s tocater for small to large Data centers.
Product Family Power Topology Applications
Agilon Under 1 kVA Single-Phase UPS PC and Peripherals
Amplon 1 kVA or higher Single-Phase UPS Server and Network Equipment
Ultron 10 kVA or higher Three-Phase Online UPS Data center and Industrial Equipment
Modulon 20 kVA or higher Three-Phase Modular Online UPS
Modular unit expansion and redundant power supplycan be achieved within a single rack.
RT Series 1/2/3 KVAThe Amplon RT 1-3kVA series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment. It supports personal computers, networks, servers, VoIP and telecommunications. The Amplon RT 1-3kVA series features an output power factor of 0.9 and best-in-class AC-AC efficiency up to 94% resulting in greater energy savings.
Power Rating
[1K] 1kVA/ 0,9KW
[2K] 2kVA/ 1,8KW
[3K] 3kVA/ 2,7KW
Input
Nominal Voltage 200/208/220/230/240 Vac
Voltage range 120 ~ 280Vac
Frequency Range 50/60 Hz ± 10 Hz
Power Factor > 0.99 (full load)
RT Series 5/6/10 KVAThe Amplon RT series delivers double-conversion on-line technology, high power density and input power factor, and low current harmonics with its advanced architecture. Designed in a rack or tower configuration with an LCD display, Amplon RT offers advanced performance for servers, data centers, networking, VoIP and telecommunications.
Power Rating
[5K] 5kVA/4,5kW
[6K] 6kVA/5,4kW
[10K] 10kVA/9kW
Input
Nominal Voltage 200/208/220/230/240 Vac
Voltage range 100~300Vac
Frequency Range 40 ~ 70 Hz
Power Factor > 0.99 (full load)
R Series 1/2/3 KVA (LONG BACK-UP)The Amplon R series is a true on-line, double-conversion UPS that protects devices from potential power problems such as spikes, surges and brownouts. It is available in either a rack or tower configuration and is recommended for servers, VoIP, telecommunications and networking. The Amplon R series is designed for long backup time applications with the addition of a customized battery source. The inbuilt high level charger shortens the recharging period and increases availability.
Power Rating
[1K] 1kVA/700W
[2K] 2kVA/1400W
[3K] 3kVA/2100W
Input
Nominal Voltage 220/230/240 Vac (single phase)
Voltage range 80-280 VAC
Frequency Range 40 – 70Hz
Power Factor > 0,97
Output
Voltage 200/208/220/230(default)/240 Vac (single phase)
Voltage Harmonic Distortion < 3% (linear load), < 6% (computer load)
Voltage Regulation ± 2%
Wave Form Pure sine wave
Battery Charger 36V (Internal/External)
Battery Charger 240V (External)
Battery Charger 192V (External)
Battery Charger 240V (Internal)
Additional battery charger for 3pcs battery string. N-series 1kVA / R-Series 1kVA
Additional battery charger for 20pcs battery string. RT-series 10kVA /EH-series
Additional battery charger for 16pcs battery string. RT-series 5/6kVA
Additional battery charger for 20pcs battery string. RT-series 10kVA
UP
S C
har
gin
g S
yste
m
LONG BACK-UP UPS SOLUTIONS
Maintenance Bypass Box
Maintenance (manual) bypass box for two parallel UPS installation, ca-pacity up to 11kVA. The box can be used only for redundant parallel con-nection, because of manual breaker capacity 63A and total power 11kVA. Bypass box is also possible to connect to both UPS by parallel cables and UPS are receiving the status of manual bypass breaker.
EH Series, Three Phase In - Single Phase Out10/15/20 kVAThe Ultron EH series is an online double-conversion 3p-1p UPS which provides reliable power protection for IT rooms, telecommunications, banking, medical facilities and industry. Supported with DSP based technology, it offers rapid computation capabilities that enhance system stability and provide precise voltage to load. The Ultron EH series offersmany superior features including N+X parallel redundancy and a built-in manual bypass switch to guarantee higher availability and reliability for protecting your critical loads.
EH-10K / EH-15K / EH-20K
[10K] 10kVA / 8kW
[15K] 15kVA / 12kW
[20K] 20kVA / 16kW
Input
Nominal Voltage 220/380 Vac, 230/400 Vac, 240/415 Vac
Voltage range 208~304 Vac ( 50%~100% load) / 305~477 Vac (100% load)
Power Factor > 0.95 (full load)
Output
Voltage 220/230/240 Vac
Voltage Harmonic Distortion < 3% (linear load)
Voltage Regulation ± 2%
LabSecurity
IndustrialTelecomData Center
Medical Metro
Network
Banking
$
Retail
HPH Series, Three Phase | 20-120 kW
The Ultron HPH is a true online double-conversion UPS offering the best-in-class combination of maximum available power, unbeatable energy efficiency and superior power performance for small data centers and other mission critical applications requiring highly reliable power protection. With fully rated power (kVA=kW); the Ultron HPH provides maximum available power without de-rating the UPS. Thanks to three level inverter and Delta´s innovative three phase PFC topology, it features low iTHD <3%, up to 96% AC-AC efficiency and 99% efficiency in ECO mode resulting in significant TCO (Total Cost of Ownership) savings. Facilitating increased availability through special watch-dog design, the Ultron HPH is an ideal solution for protecting your mission critical operations.
HPH-20K, HPH-30K, HPH-40K | HPH-60K, HPH-80K, HPH-100K, HPH-120K | HPH-20K-BN/B, HPH-30K-BN/B, HPH-40K-BN/B
[20K] 20 kVA/kW
[30K] 30 kVA/kW
[40K] 40 kVA/kW
[60K] 60 kVA/kW
[80K] 80 kVA/kW
[100K] 100 kVA/kW
[120K] 120 kVA/kW
Input
Nominal Voltage 380/220Vac, 400/230Vac, 415/240Vac (3 phase, 4-wire + G)
Voltage range [20-40K]: 300~477 Vac (full load), 228~300 Vac (70%~100% load)[60-120K]: 332~477 Vac (full load), 228~332 Vac (63%~100% load)
Output
Voltage 380/220Vac, 400/230Vac, 415/240Vac (3 phase, 4-wire + G)
InsightPower Client
• Power Off Time Settings• Responsive Actions• Display• Scheduling• Event Tracking• Smart Power Off
Sentry 2012Delta’s power management software family, including InsightPower Manager, InsightPower Client, UPSentry, and Shutdown Agent, empowers users with the highest levels of oversight and control over UPS systems.
DPS Series 160-500 KVAThree Phase
Delta’s Ultron DPS is a double-conversion and IGBT-rectifier three phase UPS. With the three level IGBT topology for both PFC (power factor correction) and inverter, the Ultron DPS features industry leading performance of up to 96% AC-AC efficiency.
DPS-160K / DPS-200K / DPS-300K / DPS-400K / DPS-500K
[160K] 160kVA/144kW
[200K] 200kVA/180kW
[300K] 300kVA/270kW
[400K] 400kVA/360kW
[500K] 500kVA/450kW
Input
Nominal Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire + G)
Voltage range 300~477 Vac (full load), 208~300 Vac (70%~100% load)
Output
Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire + G)
Control and LCDDisplay Panel
Power ManagementSoftware
NT Series, Three Phase20-500 kVA
The Ultron NT series is a three phase UPS featuring customized I/P-O/P ratings for various applications. With N+X parallel redundancy or expansion, it guarantees high availability and reliability for your critical loads.
NT-20K / NT-30K / NT-40K / NT-50K NT-60K / NT-80K / NT-100K / NT-120K NT-160K / NT-200K / NT-260K NT-320K / NT-400K / NT-500K
[20K] 20kVA/18kW
[30K] 30kVA / 27kW
[40K] 40kVA / 36kW
[50K] 50kVA / 45kW
[60K] 60kVA / 54kW
[80K] 80kVA / 72kW
[100K] 100kVA / 90kW
[120K] 120kVA / 108kW
[160K] 160kVA / 144kW
[200K] 200kVA / 180kW
[260K] 260kVA / 234kW
[320K] 320kVA / 288kW
[400K] 400kVA / 360kW
[500K] 500kVA / 450kW
LabSecurity
IndustrialTelecomData Center
Medical Metro
Network
LabSecurity
IndustrialTelecomData Center
Medical Metro
Network
Modulon FamilyIn the Delta UPS product line, the Modulon family features a three-phase modularization architecture for power rating requirements above 20 kVA and supports data centers, mid-large network equipments, data storage centers andfinancial balance centers. The word Modulon (Modular + on) highlights its core feature – modularization. Customers can purchase UPS systems with greater flexibility based on their initial unit needs and future needs for scalability to lower their TCO and maximize system benefits.
NH Plus Series, Three Phase20-120 kVAThe Modulon NH Plus series is Delta’s modular UPS featuring high efficiency, hot-swappable modular structure and N+X redundancy. With its high efficiency, the NH Plus series delivers remarkably low total cost of ownership in terms of both capital expense and operating expense.
NHP-20K / NHP-40K / NHP-60K | NHP-80K / NHP-100K / NHP-120K
[20K] 20kVA / 18kW
[40K] 40kVA / 36kW
[60K] 60kVA / 54kW
[80K] 80kVA / 72kW
[100K] 100kVA / 90kW
[120K] 120kVA / 108kW
Input
Nominal Voltage 380/220V, 400/230V, 415/240V (3 phase, 4-wire +G)
Voltage range 300~477 Vac (full load), 208~300 Vac (70%~100% load)
Output
Voltage 380/220V, 400/230V, 415/240V (3 phase, 4-wire +G)
DPH Series, Three Phase25-75/150/200 kWThe Modulon DPH supports ultimate availability for data center oper-ations and provides the benefit of “pay as you go” without over-siz-ing the UPS. While achieving ultimate availability, the Modulon DPH does not compromise on power efficiency performance. When availability, efficiency and expanding according to business needs are essential, the Modulon DPH is the ideal UPS system to provide power protection and total cost of ownership (TCO) savings.
DPH 75kW System | DPH 150kW System | DPH 200kW System
DPH 75kW System 25, 50, 75 kVA
DPH 150kW System 25, 50, 75, 100, 125, 150 kVA
DPH 200kW System 25, 50, 75, 100, 125, 150, 175, 200 kVA
Input
Nominal Voltage 380/220V, 400/230V, 415/240V (3 phase, 4-wire +G)
Voltage range 176~276 / 305~477 Vac
Output
Voltage 380/220V, 400/230V, 415/240V (3 phase, 4-wire +G)
Scalable and hot-swappablepower modules
Optional Rack-Mount PDC with hot-swappable breakermodules and control modules
Delta InfraSuiteData Center Infrastructure Solutions
SNMP Card – Legacy IPv4
SNMP card is additional communication interface between UPS and the network. Allows UPS remote control and monitoring trough network. The card can be installed in all type of UPS with Smart slot.
Relay I/O CardFOR UPSThe relay I/O card expands communication ability of the UPS and can be installed in the Smart slot. The card allows monitoring of UPS with 6 output programmable dry contacts. 1 input dry contact can be set as UPS shutdown.
Modbus CardConvert status and parameter data of your UPS to comply with the standard Modbus protocol. Modbus card can be installed in UPS Smart Slot.Communications Interface – 1 x RS232 port; 1 x RS485 or RS422port
Mini SNMP Card
SNMP card is additional communication interface between UPS and the network. Card allows UPS remote control and monitoring through the network. The card can be installed into UPS with Mini-card slot.
SNMP CARD ALL-IN-ONE IPV6
SNMP card is additional communication interface between UPS and the network.
Mini Modbus Card
Convert status and parameter data of UPS to comply with the standard Modbus protocol. The card can be installed in UPS Mini card slot.
InfraSuite EnviroProbe
EnviroProbe monitors temperature, humidity in a single cabinet or area and transmits signals from environment sensor devices in the data center (e.g.: door sensors, smoke detectors, fire detectors, water-leakage detectors etc.) to management via network.
Mini USB Card
Mini USB card expands communication ability of the UPS and can be installed in Mini card slot.
JHB: Tel: 011 462-4253 / Tel: 010 591-1713 , Fax: 011 462-4310KZN (Durban) : Tel: 031 569-2854, Fax: 031 569-2864
CPT (CapeTown): Tel: 021-300-1727, Fax: 021 300-1728 Bloemfontein: Tel: 051 011 0158, Fax: 051 444-1996 Mbombela: Tel: 013 004-0012, Fax: 013 004-0011 Tshwane: Tel: 012 763-9300, Fax: 011 462-4310
We are country wide
Network UPS management
Remote monitoring via SNMP & HTTP
Event logs & metering data keeping
UPS and system funtion configuration from any client
Card allows UPS remote control and monitoring trough network and can be installed into all type of UPS with Smart slot, except N-series and R-series.