TecInTex: Technology Integration into Textiles: Empowering Health Gerhard Tröster

Transcript of tecintex

Page 1: tecintex

TecInTex:

Technology Integration into Textiles:

Empowering Health

Gerhard Tröster

Page 2: tecintex

April 27, 2012 G. Tröster

Structure

• Partners– ETH Zürich Electronics Lab (G. Tröster, G. Salvatore)– EMPA St Gallen, Dübendorf (R.Rossi, M.Heuberger,

F. Clemens)– CSEM Neuchatel (G. Voirin, J. Luprano)– University Hospital Zurich (M. Wolf)– Paraplegic Center Nottwil (U.Baumberger)– industrial partners

2/

Page 3: tecintex

April 27, 2012 G. Tröster 3/

Mission of TecInTex:

Provide the core modules to design and to manufacture sensing and acting textiles

From fibres to clothes to people

Fibres Fabrics Clothes

Evaluation

Page 4: tecintex

April 27, 2012 G. Tröster 4/

‚Healthcare Demonstrators‘

• NIRS (Near Infrared Spectroscopy) in socks images O2

– Early detection and treatment of peripheral vascular disease (PVD)

enough O2

lack of O2

• ‚Intelligent‘ underwear for paraplegic people to prevent and to treat ulcer

Light Source

Detector

High decubitus risk pressurehumiditytemperatureoxygenation

Page 5: tecintex

April 27, 2012 G. Tröster

Highlights

• E-fibers• O-fibers• E-stripes

5/

Page 6: tecintex

April 27, 2012 G. Tröster

Metal/plasma polymer nanocomposite coatings

6/

TEM micrographs of Ag/C:H plasma polymer coating with microstructure in the percolation region.

resistivity sensitive to pressure, strain, humidity

Page 7: tecintex

April 27, 2012 G. Tröster 7/

PEDOT:PSS Coatings on Metallized Fibers: Process

Uncoated fiber

Coated fiber

PEDOT:PSS

solution

Heater 1

Heater 2

Page 8: tecintex

April 27, 2012 G. Tröster 8/

PEDOT:PSS Coatings on Metallized FibersConductivity

PEDOT:PSS with 10% dopant

PEDOT:PSS with 10% DMSO

Doping Multi-Layer

Page 9: tecintex

April 27, 2012 G. Tröster 9/

PEDOT:PSS Coatings on Metallized FibersResults

Uncoated silver metallized PA fiber

Thin Coatings on Single Fibers

Uncoated silver metallized PA fiber

30µm100µm

Coated with PEDOT:PSS750 nm

Page 10: tecintex

April 27, 2012 G. Tröster 10/

Pressure Sensor based on elastic polymer fibers

www.empa.ch/lpp

applied pressure

out-coupled light

out-coupled lightOptical Fiber

Light Intensity I0Light Intensity I1

0 50 100 150 200 250 300 350 4000%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

Time [s]

Nor

mal

ized

sig

nal

Sensitivity 0.2 N/cm to 20 N/cm .

Page 11: tecintex

April 27, 2012 G. Tröster

Biosensing using optical fibers

• Monitoring of pH and protease activity on the skin, e.g. in chronic wounds

11/

Page 12: tecintex

April 27, 2012 G. Tröster

pH- Sensing

• pH dyes encapsulated in porous sol-gel

12/

pH

Page 13: tecintex

April 27, 2012 G. Tröster

Protease (MMP9) activity detection

• Digestion of colored layer

13/

MMP980 µg/mL

30 µg/mL

200 µg/mL

Page 14: tecintex

April 27, 2012 G. Tröster 14/

Prototype for sensing optical fibers

LabView Interface

Fluidic cell

Acquisition card and optics

PD

Real-time pH measurement in 10% blood serum

Page 15: tecintex

April 27, 2012 G. Tröster 15/

Opto-electronic components for prototype

Optical couplers

Page 16: tecintex

April 27, 2012 G. Tröster 16/

Perfusion measurement with POF

Page 17: tecintex

April 27, 2012 G. Tröster

E-Stripes: Thin film technology into textiles

• Planar thinfilm technology – Sensors– Transistors– Integrated circuits

• Small (< 0.5mm) stripes woven into textiles

17/

Page 18: tecintex

April 27, 2012 G. Tröster

Weaving using Production Tools

18/

• ~ 1.6 m wide• Stripes 1 – 2 mm

Page 19: tecintex

April 27, 2012 G. Tröster 19/

Embroidery

45 cm

18 cm

Page 20: tecintex

April 27, 2012 G. Tröster

Gas sensors with Carbon-Black:Process flow• Polymers: PVP, PVUB, PIB, PS

20/

Page 21: tecintex

April 27, 2012 G. Tröster 21/

Gas sensors: sensitivity

Page 22: tecintex

April 27, 2012 G. Tröster 22/

Sensor Fusion (PCA Principal Component Analysis)

Page 23: tecintex

April 27, 2012 G. Tröster 23/

IGZO-bendable 1μm-TFTs:

Thin film devices fabricated on flexible plastic substrate

Page 24: tecintex

April 27, 2012 G. Tröster

Outlook

• Design and validation of the demonstrators– ethical approval– biocompatibility approval– clinical setting– pilot studies