Technomed Chlorophyll Meter NEW
-
Upload
atul-badola -
Category
Documents
-
view
214 -
download
1
description
Transcript of Technomed Chlorophyll Meter NEW
ACM-1211-725 S-PC
Weiber-0090-502
An ISO 9001:2208 | ISO 14001:2008 | ISO 13485WHO:GMP Products | GLP Compliant Products
The Weiber Chlorophyll Meter instantly measures
chlorophyll content or "greenness" of your plants to reduce
the risk of yield-limiting deficiencies or costly over
fertilizing. The Weiber-SPAD-0090 502 Plus quantifies
subtle changes or trends in plant health long before they're
visible to the human eye. Non-invasive measurement;
simply clamp the meter over leafy tissue, and receive an
indexed chlorophyll content reading (0-99.9) in less than 2
seconds. Assess nitrogen needs by comparing in-field
Weiber-SPAD-0090 readings to university guidelines or to
adequately fertilized reference strips. Research shows a
strong correlation between Weiber-SPAD-0090
measurements and leaf N content.
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
NEW FEATURES
• Trend graphing stores and displays up to 30 measurements
• Waterproof design
The Weiber Plus meter can be purchased with or
without a built-in data logger. The data logging
version (Item 2900PDL) allows you to compile
readings for statistical analysis. Includes an RS-
232 port for communicating with a PC* and/or
portable GPS receiver**. Use geo-referenced
data to correlate N measurements to yield maps
or download the data into mapping software.
This robust field-data collection device has a
capacity of 1,488 measurements when coupled
with a GPS receiver or 4,096 measurements
when used without GPS. Requires software
running on Windows 98 or higher. GPS/DGPS
cable required for geo-referenced operation.
Our chlorophyll meter measures the leaf in two
wavelength range of light transmission factor to
determine the relative amount of leaf chlorophyll
present, that is, selective absorption in the
chlorophyll-specific wavelengths of light two
wavelength regions, according to the amount of
light transmission leaves to calculate the
measure value.
OPERATING PRINCIPLE:
FEATURES
USAGE:
• Compact and lightweight for portability.
• Quick, easy measurement. Measurements are
taken by simply inserting a leaf and closing the
measuring head. It.
• Water-resistant.
• Low power consumption.
• Small measuring area.
• High accuracy al lows close examination of
growing conditions.
• Data memory.
• Reading checker.
Our Chlorophyll meter can instantly measure the relative
content of chlorophyll of plants, or "green level", the
chlorophyll content of plant leaves indicates the plant's own
conditions, the leaves of plants are growing well will contain
more chlorophyll, chlorophyll content and leaf nitrogen in
There is a close relationship between content and therefore
measured values of chlorophyll, it also shows the true plant
nitro-demand, through this instrument it is easy to calibrate
the dose of fertilizer to improve nitrogen utilization and
protection of the environment (prevention of excessive
nitrogen fertilizer causing water pollution)
WeiberChlorophyll Meter
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
Features Fast measurement time
LCD direct display of chlorophyll values
Compact portable instrument can carry
into the field measuring
Survey Sample A variety of plant leaves
Measurement Area Ö10mm
Measurement Two-wavelength optical density difference method
Sensor Silicon photodiode
Display Measured value: 3-digit liquid crystal display
Measurement Views: 2 digit LCD display
Minimum measurement interval Is less than 2 seconds
Range 0.0-99.9 TECHNO-SPAD-0090
Accuracy ± 1.0 WEIBER-SPAD-0090 (room temperature,
WEIBER-SPAD-0090 values ranged from 0-50)
Repeatability Within ± 0.3 TECHNO-SPAD-0090 units
(WEIBER-SPAD-0090 value between 0-50)
Reproducibility Within ± 0.5 TECHNO-SPAD-0090 units
(WEIBER-SPAD-0090 value between 0-50)
Operating Temperature 050 ?0Storage Temperature -20 ~ ~55 C
Memory capacity and the 30 data, automatically calculates and displays the average
key features Power Switch: ON for the opening, OFF is off; AVG (average)
bond: Calculate the average of the data in memory; DEL
(clear all data) key: Clear all the data in memory devices; DISP
(display) button: Displays the data memory storage devices;
MEAS (measurement) button: Press MEAS key to be measured.
Power 2 5 AA alkaline manganese batteries or carbon - zinc batteries
Battery Life Each group of two cells can be maintained
more than 20,000 times operation
Dimensions (L × W × H) 155mm* 70mm*42mm
Weight 320g(Not including batteries)
Technical Parameters
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
SALES OFFICE (INDIA)
312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA
Tel: 0091-11-23646703, 23643054
(M) +91-9313971681| Email: [email protected]
SALES OFFICE (HONG KONG)
Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC).
Tel: 0086-13929598046 | 0086-18922303099
Email: [email protected]
SHOWROOM
141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA
Tel: 0091-0-9312219738 (M) +91-9717741167
Email: [email protected]
SALES OFFICE (RUSSIA)
Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA
Tel: 0049-79592345 | Email: [email protected]
www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
TECHNOCRACY PVT. LTD.