Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on...
Transcript of Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on...
![Page 1: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/1.jpg)
Technical Training Seminar on “Practical Field Testing DOCSIS 3.0”
for CCTA Member Companies
August 24, 25 and 26, 2010 San Juan, Puerto Rico
Tony Holmes
Mario Sebastiani
![Page 2: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/2.jpg)
Practical Field Testing – DOCSIS 3.0
OverviewQuick discussion of DOCSIS 3.0 importanceImpact of D3 on testingD3 deployment and preventive maintenancePractical methods for testing D3 signal transmission qualityTroubleshooting the Return PathMonitoring the Return Path
![Page 3: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/3.jpg)
Practical Field Testing – DOCSIS 3.0
Higher Data Rates– Channel BondingDynamic Load Balancing– Dynamic Channel Change & Per Packet Load BalancingBetter Bandwidth Utilization– Source Specific Multicast– Multicast Header SuppressionHigh Quality IP Video– Multicast Quality of ServiceMore IP Addresses When You Need Them– IPv4 and IPv6 Support
DOCSIS 3.0
![Page 4: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/4.jpg)
Practical Field Testing – DOCSIS 3.0
Enhanced Security– 128 bit AES encryption (Advanced
Encryption Standard)– Increased Cable Modem
provisioning process securityOption to Increase Upstream Bandwidth– Option for 5-85 MHz upstream supportPowerful Reporting to Manage Traffic– Cable modem diagnostic log– Enhanced signal quality monitoring– Service statistics reporting - IPDR
DOCSIS 3.0
![Page 5: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/5.jpg)
Practical Field Testing – DOCSIS 3.0
Impact on TestingNeed higher reliability and performance, while minimizing operating expense– Increase efficiency and productivity
DOCSIS 3.0 – Group of signals (bonded) with interrelated relevancePhysical transmission is same as DOCSIS 2.0IP related measurements require embedded DOCSIS 3.0 modem
![Page 6: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/6.jpg)
Practical Field Testing – DOCSIS 3.0
Higher Data RatesUpstream Capacity with 6.4MHz & 64QAM– Two channels, 60 Mbps– Three channels, 90 Mbps– Four channels, 120 Mbps
Downstream Capacity with 6MHz & 256QAM– Two channels, 80 Mbps– Three channels, 120 Mbps– Four channels, 160 Mbps– Eight channels, 320 Mbps
![Page 7: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/7.jpg)
Practical Field Testing – DOCSIS 3.0
Channel BondingExample:
![Page 8: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/8.jpg)
Practical Field Testing – DOCSIS 3.0
“Primary” Channels
One Channel in Group carries timing info for whole group
Each Channel in Group carries its own timing information
![Page 9: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/9.jpg)
Practical Field Testing – DOCSIS 3.0
Proactive Testing Makes Sense
Fewer emergencies, lower operating expense, higher customer satisfaction“Old school” plant performance testing– Sweep– Leakage– End-of-line testing
![Page 10: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/10.jpg)
Practical Field Testing – DOCSIS 3.0
Plant Qualification Checklist
Headend RF alignmentDownstream 256-QAM testing and qualificationUpstream 64-QAM testing and qualification– Avoid frequencies near the roll-off or band edges– Avoid frequencies susceptible to ingress, if possible– Control ingress, noise, CPD and laser clipping– Tighten RF leakage thresholds
![Page 11: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/11.jpg)
Practical Field Testing – DOCSIS 3.0
DOCSIS 3.0 ChecklistTest equipment– DOCSIS 3.0 field test meter
64-QAM signal source
Upgrade or purchase new QAM Analyzers
![Page 12: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/12.jpg)
Practical Field Testing – DOCSIS 3.0
Preventive Maintenance Checklist
Do complete system sweep every 12-18 months (all actives)End-of-line digital testing (MER & BER)Leakage TestingReturn Path MonitoringDaily reports (use as historical references)
![Page 13: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/13.jpg)
Practical Field Testing – DOCSIS 3.0
Installation Testing Pays OffComprehensive with minimal impact on Tech time– Establishes baseline– “Certification” leads to higher quality and
reliability Level scan, MER, BER, cable modem statistics, ingress, leakage
![Page 14: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/14.jpg)
Practical Field Testing – DOCSIS 3.0
Preparation TestingUpstream needs special attentionNode certification: return path spectrum – Extended period of testing
requiredSpeed is of the essenceSpectrum suitability analysis – DISP, ADISP
![Page 15: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/15.jpg)
Practical Field Testing – DOCSIS 3.0
Post-Deployment TestingInstallation– Cable modem statistics– Throughput
![Page 16: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/16.jpg)
Practical Field Testing – DOCSIS 3.0
Test AutomationEfficient, error-free testingDOCSIS 3.0 environment autotest includes:– Channels in a group– Set of tests to be performed on each channel– Performance limits to analyze
test result
![Page 17: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/17.jpg)
Practical Field Testing – DOCSIS 3.0
Typical D3 AutotestConsider sequence to minimize ranging and registeringTest relevant parameters
![Page 18: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/18.jpg)
Practical Field Testing – DOCSIS 3.0
Typical Autotest for D3Once the autotest is built and loaded into the meter:Tech pushes one button and runs specific tests on specified channelsAlerts tech to failures right away
![Page 19: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/19.jpg)
Practical Field Testing – DOCSIS 3.0
Typical Autotest for D3
Tech can then retrieve and view supporting test details, or save files for uploading to server.
![Page 20: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/20.jpg)
Practical Field Testing – DOCSIS 3.0
D3 Autotest Results
![Page 21: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/21.jpg)
Practical Field Testing – DOCSIS 3.0
D3 Autotest Results
![Page 22: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/22.jpg)
Practical Field Testing – DOCSIS 3.0
D3 Autotest Results
![Page 23: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/23.jpg)
Practical Field Testing – DOCSIS 3.0
D3 Test Macro Summary Report
Results may be retained, displayed in supporting software
![Page 24: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/24.jpg)
Practical Field Testing – DOCSIS 3.0
Transmission System Troubleshooting Tools
QAM Analyzer – in the field and in the headend/hub siteReturn Path Monitoring EquipmentProbe – bi-directionalLeakage System
![Page 25: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/25.jpg)
Practical Field Testing – DOCSIS 3.0
Plant Performance TestingForward and reverse sweepUpstream QAM analysis from EOLLeakage (tightened threshold?)
![Page 26: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/26.jpg)
Practical Field Testing – DOCSIS 3.0
MERMER degradation– does not effect picture quality until failure
MER accounts for– amplitude noise– phase noise
![Page 27: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/27.jpg)
Practical Field Testing – DOCSIS 3.0
Troubleshooting Low MERIs it noise or interference?– Noise may indicate an amplifier or other active component failure– Interference may indicate:
Distortion – active componentIngress – leakage (stray RF in means RF straying out)
Spectrum analysis helps– Use error vector spectrum to see within the channel range (under
the haystack)Constellation analysis (tell-tale shapes – donuts, clouds, etc.)
![Page 28: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/28.jpg)
Practical Field Testing – DOCSIS 3.0
Error Vector SpectrumTo view the noise floor under QAM the carrier needs to be removed
![Page 29: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/29.jpg)
Practical Field Testing – DOCSIS 3.0
Troubleshooting High BERIs MER low? (see last advice)Pre-FEC or Post-FEC, measure of severityAre bit errors continuous or sporadic?– Look at graph of errors over time– Can time signature be determined? (may give clue to
cause)Is BER failure frequency (channel) specific and sporadic?– Look at error vector spectrum over time
![Page 30: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/30.jpg)
Practical Field Testing – DOCSIS 3.0
Impulse BERBER– Corrupted bits/total bits received
Shows BER before and after FECErrored Seconds– The number of seconds with at least one corrected codeword
Severely Errored Seconds– The number of seconds with at least one uncorrectable
codewordValuable troubleshooting tool– Whenever there are errors use this screen to divide and
conquer
![Page 31: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/31.jpg)
Practical Field Testing – DOCSIS 3.0
BERBit Error Rate is the number of bits in error divided by the total number of bits in the data transmissionPre BER– System Margin
![Page 32: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/32.jpg)
Practical Field Testing – DOCSIS 3.0
Forward Error CorrectionFEC– Corrects errors to a point
Pre FEC BER (Before Correction)
Post FEC BER (After Correction)
![Page 33: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/33.jpg)
Practical Field Testing – DOCSIS 3.0
Troubleshooting the Return Path
![Page 34: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/34.jpg)
Practical Field Testing – DOCSIS 3.0
Components of The Guardian II SystemGuardian II integrated server package9581 SST R4 Headend unit8310 RSAViewer II client software for NOC operationsADIA historical analysis suiteSST Configure softwareField units:– 860 DSPi– RSVP2
![Page 35: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/35.jpg)
Practical Field Testing – DOCSIS 3.0
Troubleshooting IngressCompare local test point spectrum to headend/hub spectrumUse I-stop probe to load local test point and see if headend spectrum drops– If it drops the problem is farther down the line– If it doesn’t the problem is closer to the headend/hub– Low-pass filter is also recommended
![Page 36: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/36.jpg)
Practical Field Testing – DOCSIS 3.0
Reverse IngressTop displays LocalBottom displays headendMove your location until you find the source of the ingress
![Page 37: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/37.jpg)
Practical Field Testing – DOCSIS 3.0
Return Sweep ModeDisplays – Gain/Tilt – Frequency Response – Headend Ingress levels
Gain Information– Difference between Headend
nominal and sweep carrier levelTilt Information– Difference between low and high
pilots carrier levelsPads and Equalizers – Gain/Tilt values of 0 are perfect– Values other than 0 indicate the
change in Pad/EQ necessary to bring the system into alignment
![Page 38: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/38.jpg)
Practical Field Testing – DOCSIS 3.0
Return Sweep ModeFrequency Response Trace– Plots received (Headend) level
for each sweep carrier – Scale per Division 2 dB
– Ideal Trace is a flat line
Impairments to frequency response– Damaged Cable – Damaged actives or passives– High Ingress Levels
![Page 39: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/39.jpg)
Practical Field Testing – DOCSIS 3.0
RSVP Installation VerificationContinuity Test
– Talks directly to the 9581 SST
headend unit
Measures the C/N
Displays the test Results
Shows a Pass or Fail
![Page 40: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/40.jpg)
Practical Field Testing – DOCSIS 3.0
Troubleshooting transients in upstream signal bands
Test feature uses limits to remove legitimate traffic from the spectrum viewRemoves the haystack and reveals the needleProvides insight in monitoring as well as troubleshootingSpectrum acquisition speed reveals fast transients
![Page 41: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/41.jpg)
Practical Field Testing – DOCSIS 3.0
In-channel Upstream Spectrum AnalysisReturn spectrum is getting crowded, making inspection of spectrum problems difficultTest mode can be used to see the ingress or distortion “underneath” an upstream cable modem carrier, VoIP carrier, or any bursty signalTroubleshooting made easy– Divide & Conquer– Source typically a home
![Page 42: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/42.jpg)
Practical Field Testing – DOCSIS 3.0
Laser ClippingTypically caused by input overload, operating in non-linear transfer rangeWhere it shows up:– Return path spectrum, distortion products
above max frequency range– Constellation – intermittent compression– Impulse BER – bit errors due to clipping
![Page 43: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/43.jpg)
Practical Field Testing – DOCSIS 3.0
Understanding the Spectrum Analyzer
Reference / InputDetectorSweep TimeRBWdB/DivFrequency TuningMax/Min Hold
![Page 44: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/44.jpg)
Practical Field Testing – DOCSIS 3.0
Is It System Noise?l Internal spectrum analyzer
noise may be too high to allow system noise measurement∗ use the disconnect test
![Page 45: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/45.jpg)
Practical Field Testing – DOCSIS 3.0
Noise-Near-NoiseCorrection (dB)
Noise Drop For Disconnect Test, dB0 1 2 3 4 5 6 7 8 9 10
0
1
2
3
4
5
6
7
8
9
10l If > 10 dB drop, no corrections needed
l If > 3 dB drop, correct by using the graph below
l If < 3 dB drop, use a 20-30 dB gain, <10 dB noise figure preamplifier
The Disconnect Test
![Page 46: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/46.jpg)
Practical Field Testing – DOCSIS 3.0
0.5 dB
1.2 dB
3.0 dB
6.9 dB
10.0 dB
6.0 dB
3.0 dB
1.0 dB
(a) Disconnect Test (b) Correction Values
SystemNoise
AnalyzerNoise
Correcting Analyzer for Noise-Near-Noise
![Page 47: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/47.jpg)
Practical Field Testing – DOCSIS 3.0
Ingress Mitigation TestThis is a test where you can quickly check thedrop and home wiring for ingress
Set Ref level so as to not over-loadthe meterDetector set for averagingRBW at 300 KHz10 db/divSpectrum 5-108 MHzUse peak hold
![Page 48: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/48.jpg)
Practical Field Testing – DOCSIS 3.0
Ingress Mitigation TestWhat you should see is NOTHING!
Just the noise floor
![Page 49: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/49.jpg)
Practical Field Testing – DOCSIS 3.0
Ingress Mitigation TestLook for ingressby using the “Peak Hold” function
Identify the problem by workingback towards the house
![Page 50: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/50.jpg)
Practical Field Testing – DOCSIS 3.0
Laser Clipping Return Path Spectrum
Note the products above 42 MHz
![Page 51: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/51.jpg)
Practical Field Testing – DOCSIS 3.0
Monitoring the Return
![Page 52: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/52.jpg)
Practical Field Testing – DOCSIS 3.0
Viewer II User Interface
Components– Status Tree– Incident Log– Alarm History– Spectrum Display
![Page 53: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/53.jpg)
Practical Field Testing – DOCSIS 3.0
Node Status TreeGeography– Groups nodes by
CityHeadend Hubsite
Services– Groups nodes by
CMTSBlade
![Page 54: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/54.jpg)
Practical Field Testing – DOCSIS 3.0
ADIA Historical Analysis ServerCollects spectral information from the 9581 SST headend units – Spectral information contains Max/Min/Avg
ingress information collected in 9581 SST and compressed into 15 minute summaries
– Return Path performance information against user specified limits
Provides database storage for 3000 nodes over a one year time period
![Page 55: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/55.jpg)
Practical Field Testing – DOCSIS 3.0
Spectral HistoryReview ingress signature of selected node– Over user specified
time period– Max/Min/Avg traces– With live spectral
overlay
![Page 56: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/56.jpg)
Practical Field Testing – DOCSIS 3.0
Spectral HistoryRetrieve Spectral History – Both spectral and time
based views– Evaluate the severity
and duration of ingress related events
– View the waterfall graph
![Page 57: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/57.jpg)
Practical Field Testing – DOCSIS 3.0
ADIA Node Service Report
![Page 58: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/58.jpg)
Practical Field Testing – DOCSIS 3.0
Return Path ReportsWorst Offenders List– Provides summary of worst offending nodes by alarm level over
specified time periodNode Alarm Summary– Allows user to view alarms
over specified time frameAlarm History Over Time– Allows user to view alarm
history over a time period summarized by hour, day, or month
![Page 59: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/59.jpg)
Practical Field Testing – DOCSIS 3.0
•Forward Path Ingress •Return Path Ingress
Demonstration
Impairments from :
![Page 60: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/60.jpg)
Practical Field Testing – DOCSIS 3.0
ReviewDOCSIS 3.0 improves competitive position, and revenueReliability is crucial, testing helpsPractical preparation for D3 deployment and preventive maintenance check listsPractical D3 signal transmission quality testsTests for troubleshootingTest equipment D3 evolution
![Page 61: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/61.jpg)
Practical Field Testing – DOCSIS 3.0
Response to Your Questions!!!!
![Page 62: Technical Training Seminar on “Practical Field Testing ... · Technical Training Seminar on “Practical Field Testing DOCSIS 3.0 ... – Multicast Quality of Service ... Laser](https://reader034.fdocuments.in/reader034/viewer/2022051509/5adb1b007f8b9a53618d79c3/html5/thumbnails/62.jpg)
Practical Field Testing – DOCSIS 3.0Technical Training Presentation – CCTA 2009
Thank you-Gracias-Merci-Masha Danki…
Trilithic Applications [email protected] Tel: 800-344-2412----------------------------------------------------------------------Incospec Communications Inc.Your Value Adder Trilithic Re-Seller for the Caribbean
Mario Sebastiani ([email protected])Bernard How ([email protected])