TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and...

408
Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD FACILITY 105 GM DRIVE BEDFORD, INDIANA EPA ID# IND006036099 Prepared For: GENERAL MOTORS CORPORATION FEBRUARY 2003 REF. NO. 013968(32) Prepared by: Conestoga-Rovers & Associates 8615 W. Bryn Mawr Avenue Chicago, Illinois 60631-3501 Office: (773) 380-9933 Fax: (773) 380-6421 web: http:\\www.CRAworld.com

Transcript of TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and...

Page 1: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

W o r l d w i d e E n g i n e e r i n g , E n v i r o n m e n t a l , C o n s t r u c t i o n , a n d I T S e r v i c e s

TECHNICAL MEMORANDUMPHASE II STREAM INVESTIGATION

GM POWERTRAIN BEDFORD FACILITY105 GM DRIVEBEDFORD, INDIANA

EPA ID# IND006036099

Prepared For:GENERAL MOTORS CORPORATION

FEBRUARY 2003REF. NO. 013968(32)

Prepared by:Conestoga-Rovers& Associates8615 W. Bryn Mawr AvenueChicago, Illinois60631-3501

Office: (773) 380-9933Fax: (773) 380-6421

web: http:\\www.CRAworld.com

Page 2: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

TABLE OF CONTENTS

Page

1.0 INTRODUCTION................................................................................................................... 1

2.0 OBJECTIVE ............................................................................................................................. 3

3.0 SCOPE OF WORK.................................................................................................................. 4

4.0 PROJECT ORGANIZATION................................................................................................ 54.1 PROJECT PARCELS........................................................................................... 54.2 STUDY AREAS ................................................................................................... 54.3 STREAM NOMENCLATURE........................................................................... 5

5.0 GENERAL STREAM CHARACTERISTICS ....................................................................... 85.1 BAILEY’S BRANCH........................................................................................... 85.2 TRIBUTARY 1 ..................................................................................................... 95.3 TRIBUTARY 2 ..................................................................................................... 95.4 TRIBUTARY 3 ..................................................................................................... 95.5 TRIBUTARY 4 ..................................................................................................... 95.6 TRIBUTARY 5 ..................................................................................................... 95.7 PLEASANT RUN CREEK (STREAM 6) ........................................................ 105.8 UNNAMED WESTERN TRIBUTARY........................................................... 115.9 SALT CREEK..................................................................................................... 11

6.0 SAMPLING RATIONALE .................................................................................................. 126.1 FLOODPLAIN AND BANK SOIL SAMPLING........................................... 126.2 SURFACE WATER/SEDIMENT SAMPLING ............................................. 13

7.0 SAMPLING PROCEDURES ............................................................................................... 17

8.0 MAPPING AND LOCATION OF SAMPLES .................................................................. 18

9.0 STUDY AREA SAMPLE COLLECTION AND FINDINGS ........................................... 199.1 STUDY AREA 1 ................................................................................................ 199.2 STUDY AREA 2 ................................................................................................ 209.3 STUDY AREA 3 ................................................................................................ 229.4 STUDY AREA 4 ................................................................................................ 239.5 STUDY AREA 5 ................................................................................................ 249.6 STUDY AREA 6 ................................................................................................ 249.7 STUDY AREA 7 ................................................................................................ 259.8 STUDY AREA 8 ................................................................................................ 269.9 STUDY AREA 9 ................................................................................................ 279.10 STUDY AREA 10 .............................................................................................. 279.11 STUDY AREA 11 .............................................................................................. 29

Page 3: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

TABLE OF CONTENTS

Page

9.12 SUPPLEMENT VERTICAL DELINEATION SAMPLING............................................. 29

10.0 SUMMARY OF DATA ALONG MAIN STREAM SYSTEM.......................................... 31

11.0 QUALITY ASSURANCE QUALITY CONTROL............................................................. 33

12.0 REFERENCES ....................................................................................................................... 34

Page 4: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

LIST OF FIGURES(Following Text)

FIGURE 1.1 SITE LOCATION

FIGURE 1.2 SITE PLAN AND PROJECT STUDY AREAS

FIGURE 1.3 MILE POST AND TRIBUTARY IDENTIFICATION

FIGURE 6.1 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 2

FIGURE 6.2 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 3A

FIGURE 6.3 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 3B

FIGURE 6.4 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 4

FIGURE 6.5 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 5

FIGURE 6.6 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 6

FIGURE 6.7 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 7

FIGURE 6.8 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 10

FIGURE 6.9 IDENTIFIED SEEP AND SPRING LOCATIONS – STUDY AREA 11

FIGURE 9.1 STREAM SAMPLE LOCATIONS – STUDY AREA 1

FIGURE 9.2 STREAM SAMPLE LOCATIONS – STUDY AREA 2A

FIGURE 9.3 STREAM SAMPLE LOCATIONS – STUDY AREA 2B

FIGURE 9.4 STREAM SAMPLE LOCATIONS – STUDY AREA 3A

FIGURE 9.5 STREAM SAMPLE LOCATIONS – STUDY AREA 3B

FIGURE 9.6 STREAM SAMPLE LOCATIONS – STUDY AREA 4A

FIGURE 9.7 STREAM SAMPLE LOCATIONS – STUDY AREA 4B

FIGURE 9.8 STREAM SAMPLE LOCATIONS – STUDY AREA 5

FIGURE 9.9 STREAM SAMPLE LOCATIONS – STUDY AREA 6

Page 5: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

LIST OF FIGURES(Following Text)

FIGURE 9.10 STREAM SAMPLE LOCATIONS – STUDY AREA 7

FIGURE 9.11 STREAM SAMPLE LOCATIONS – STUDY AREA 8

FIGURE 9.12 STREAM SAMPLE LOCATIONS – STUDY AREA 9

FIGURE 9.13 STREAM SAMPLE LOCATIONS – STUDY AREA 10

FIGURE 9.13a STREAM SAMPLE LOCATIONS – AREA OF DEBRIS – STUDY AREA 10

FIGURE 9.14 STREAM SAMPLE LOCATIONS – STUDY AREA 11

FIGURE 10.1 PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL KEY MAP

FIGURE 10.2 PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL, STUDYAREA 2

FIGURE 10.3a PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL, STUDYAREA 3A

FIGURE 10.3b PCB ISO-CONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL, STUDYAREA 3B

FIGURE 10.4 PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL, STUDYAREA 4

FIGURE 10.5 PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL, STUDYAREA 5

FIGURE 10.6 PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL, STUDYAREA 6

FIGURE 10.7 PCB ISOCONCENTRATIONS – 0-0.33’ SAMPLING INTERVAL STUDYAREA 7

FIGURE 10.8 PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, KEY MAP

FIGURE 10.9 PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 2

Page 6: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

LIST OF FIGURES(Following Text)

FIGURE 10.10a PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 3A

FIGURE 10.10b PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 3B

FIGURE 10.11 PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 4

FIGURE 10.12 PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 5

FIGURE 10.13 PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 6

FIGURE 10.14 PCB ISOCONCENTRATIONS – 0.33-1’ SAMPLING INTERVAL, STUDYAREA 7

FIGURE 10.15 PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, KEY MAP

FIGURE 10.16 PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 2

FIGURE 10.17a PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 3A

FIGURE 10.17b PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 3B

FIGURE 10.18 PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 4

FIGURE 10.19 PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 5

FIGURE 10.20 PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 6

FIGURE 10.21 PCB ISOCONCENTRATIONS – 1-1.5’ SAMPLING INTERVAL, STUDYAREA 7

Page 7: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

LIST OF FIGURES(Following Text)

FIGURE 10.22 PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, KEY MAP

FIGURE 10.23 PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 2

FIGURE 10.24a PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 3A

FIGURE 10.24b PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 3B

FIGURE 10.25 PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 4

FIGURE 10.26 PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 5

FIGURE 10.27 PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 6

FIGURE 10.28 PCB ISOCONCENTRATIONS – 1.5-2’ SAMPLING INTERVAL, STUDYAREA 7

FIGURE 10.29 PCB ISOCONCENTRATIONS – 2-3’ SAMPLING INTERVAL

FIGURE 10.30 PCB ISOCONCENTRATIONS – 3-4’ SAMPLING INTERVAL

Page 8: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

LIST OF TABLES(Following Text)

TABLE 6.1 ANALYTICAL RESULTS SUMMARY – SURFACE WATER SAMPLES

TABLE 6.2 ANALYTICAL RESULTS SUMMARY – SURFACE WATER SAMPLES PCBANALYSIS

TABLE 6.3 ANALYTICAL RESULTS SUMMARY – SEDIMENT SAMPLES PCBANALYSIS

TABLE 6.4 ANALYTICAL RESULTS SUMMARY – GROUNDWATER SAMPLES PCBANALYSIS

TABLE 6.5 ANALYTICAL RESULTS SUMMARY – OFF-SITE SPRING/SEEP SAMPLESPCB ANALYSIS

TABLE 6.6 ANALYTICAL RESULTS SUMMARY – ON-SITE SEEP SAMPLES

TABLE 9.1 ANALYTICAL RESULTS SUMMARY – SOIL SAMPLES

TABLE 9.2 ANALYTICAL RESULTS SUMMARY – PLANT TISSUE SAMPLES

Page 9: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) CONESTOGA-ROVERS & ASSOCIATES

LIST OF ACRONYMS AND ABBREVIATIONS

Agreement Performanced-Based Corrective Action AgreementAOI Area of InterestCRA Conestoga-Rovers & Associates, Inc.Exponent Exponent, Inc.FSP Field Sampling PlanGM General MotorsIDEM Indiana Department of Environmental Managementmg/kg milligram per kilogramµ/L microgram per LiterPCB Polychlorinated biphenylPlant General Motors Powertrain Bedford PlantRCRA Resource Conservation and Recovery ActRFI RCRA Facility InvestigationQAPP Quality Assurance Project PlanSite General Motors Powertrain Bedford PlantSOP Standard Operating ProceduresSVOC Semivolatile Organic CompoundTAL Target Analyte ListTCL Target Compound ListTDS Total Dissolved SolidsTOC Total Organic CarbonTSS Total Suspended SolidsUS EPA United States Environmental Protection AgencyUS FWS United States Fish and Wildlife ServiceVOC Volatile Organic CompoundQA/QC Quality Assurance/Quality Control

Page 10: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 1 CONESTOGA-ROVERS & ASSOCIATES

1.0 INTRODUCTION

This Technical Memorandum (TM) presents a summary of the Phase II streaminvestigation activities performed during the time period of January 2002 throughAugust 2002 for the General Motors Corporation (GM) Powertrain – Bedford Plant(Plant). The off-Site stream investigation is being conducted as part of a ResourceConservation and Recovery Act (RCRA) Facility Investigation (RFI) by GM under thePerformance-Based Corrective Action Agreement (Agreement) with the U.S.Environmental Protection Agency (U.S. EPA) dated March 2001. This memorandumalso includes a summary of the analytical results of various soil samples collected at therequest of local residents in proximity to the stream system and/or GM Bedford Plant.The Site location is presented on Figure 1.1. Stream investigation activities are beingcompleted in cooperation with the U.S. EPA, Indiana Department of EnvironmentalManagement (IDEM), and the U.S. Fish and Wildlife Service (U.S. FWS).

In October 2001, Exponent, Inc. of Bellevue, Washington (Exponent) initiated Phase I ofthe stream investigation sampling in accordance with the Stream Investigation WorkPlan (Exponent, 2001). Phase I of the stream investigation resulted in the followingfindings:

• Physical characteristics of the Study Area streams, including geomorphology andsedimentation were defined.

• The presence of polychlorinated biphenyls (PCBs) in Study Area surface water,sediment, selected biota, and bank soil.

• Bioaccumulation of PCBs in aquatic biota.

Based on these findings, a second phase (Phase II) of sampling was recommended tofully evaluate PCB levels in floodplain soils which historically have received depositionof stream sediments during flood events.

The activities detailed in this TM include Phase II of stream investigation sampling andother follow-up activities to the October 2001 sampling event as presented in theBedford RFI Technical Memorandum 1, Stream Investigation Data Summary (Exponent,2001). These follow-up activities include floodplain, bank soil, sediment and surfacewater sampling on Bailey’s Branch from Outfall 002 to Pleasant Run Creek, Pleasant RunCreek (Stream 6), Salt Creek, upstream tributaries 1, 2, 3, 4, and 5 to Bailey’s Branch andthe Unnamed Western Tributary. In addition to the floodplain sampling activities, soilsamples were collected at various other parcels upon receipt and evaluation of resident’s

Page 11: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 2 CONESTOGA-ROVERS & ASSOCIATES

request for sampling on their property. Refer to Figure 1.2 for the Site Plan and ProjectStudy Areas Map and Figure 1.3 for the Mile Post and Tributary Identification.

Page 12: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 3 CONESTOGA-ROVERS & ASSOCIATES

2.0 OBJECTIVE

The objective of Phase II of the stream investigation was to delineate the extent of PCBcontamination in the Study Area floodplain, and tributaries of the original Study Areastreams. Surface water and sediment sampling was performed under low and high flowconditions. The high flow surface water results will be presented under separate cover.In addition to floodplain sampling; soil, surface water, sediment and plant samples werecollected at select locations throughout the Study Area at the request of variousresidents.

Page 13: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 4 CONESTOGA-ROVERS & ASSOCIATES

3.0 SCOPE OF WORK

Conestoga-Rovers & Associates, Inc. (CRA) conducted stream sampling collectionactivities in accordance with the Quality Assurance Project Plan (QAPP) (CRA, 2001)and the Stream Investigation Field Sampling Plan (FSP) (Exponent, 2001) submitted byGM to the U.S. EPA prior to the commencement of investigative activities. Thefollowing activities were included in Phase II of the stream investigation:

• Physical factors along the streams that may affect the transport of residual PCBswere identified. These include the identification of seeps and springs adjacent to andwithin the streambed, types of soil and/or sediment, depositional and erosionalfeatures, land use and other physical factors such as fencing, bridges, railroadtrestles, etc;

• Samples were collected from floodplain areas, bank soil, sediment and surface waterto further delineate the extent of PCBs identified during the Phase I stream sampling;

• Resident sampling per request at select locations throughout the Study Area; and

• Plant samples collected opportunistically to evaluate the potential for PCB uptakeinto plants.

Page 14: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 5 CONESTOGA-ROVERS & ASSOCIATES

4.0 PROJECT ORGANIZATION

4.1 PROJECT PARCELS

GM has designated arbitrary parcel numbers for private property that is contiguous tothe streams in the Study Area. Property information, including plat maps, was acquiredfrom the Lawrence County surveyor’s office. Based on the review of plat maps and fieldreconnaissance, GM determined property ownership and property access agreementsfrom each property owner were then obtained. In an attempt to verify propertyboundaries, CRA interviewed the property owners about boundaries when requestingaccess. See Figure 1.2 for the Site Plan and Project Study Areas.

4.2 STUDY AREAS

The original Study Area designated in the Phase I Work Plan was expanded duringPhase II sampling to include additional tributaries of Bailey’s Branch. CRA hasdesignated Study Areas for the GM Plant property and surrounding stream property.The entire area was subdivided into eleven Study Areas (1 to 11) in order to reduce thesize of and amount of information on individual maps. As such, the Study Areas are afunction of convenient geographical area and are not delineated by any physicalcharacteristics and/or geomorphology within the streams.

4.3 STREAM NOMENCLATURE

For purposes of discussion here, the streams and tributaries in the Study Area includethose listed below. The unnamed tributaries have arbitrarily been assigned numbers forclarity. See Figure 1.3 for Mile Post and Tributary Identification. General characteristicsof the listed streams and tributaries are discussed in Section 5.0.

• Bailey’s Branch – The lower reach of Bailey’s Branch is a second order tributarystream of Pleasant Run Creek that receives water from a number of small surfacedrainages, from bedrock springs, and from GM’s permitted Outfall 002. Forpurposes of this TM, the drainage leading from Outfall 002 is considered to be theprimary channel of Bailey’s Branch and other stream channels to be tributaries. Itshould, however, be noted that the upper reach of Bailey’s Branch is a first orderheadwater stream comparable in size and morphology to the numbered tributariesdescribed below. The upper and lower reaches of Bailey’s Branch are distinct in size,

Page 15: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 6 CONESTOGA-ROVERS & ASSOCIATES

gradient, and ecological habitat supported. Under dry conditions, Bailey’s Branchreceives the majority of its flow from the GM Outfall 002 discharge.

• Tributary 1 – this stream is a first order tributary upstream of Bailey’s Branch thatoriginates near Outfall 002. The drainage begins just north of Fifth Street and flowsnorth to join Bailey’s Branch. Dry weather flow is almost entirely from the GMdischarge (approximately 200,000 to 300,000 gallons per day).

• Tributary 2 – this stream is a first order tributary of Bailey’s Branch. The drainagebegins just east of Mt. Pleasant Road and flows north-northwest to join Bailey’sBranch.

• Tributary 3 – this stream is a first order tributary of Bailey’s Branch that includes twosmall drainages at its headwaters. The first begins on GM property just north of theon-Site landfill (former north disposal area) and east of GM Drive. The first drainageis typically dry in the extreme upper portions and includes spring and seep waterdownstream prior to joining the second drainage northeast of the former northdisposal area. The second drainage begins just east of GM’s former Outfall 003 at aspring on the bedrock surface. This second drainage flows to the northeast and joinsthe first drainage on GM property. Tributary 3 continues to the northeast to joinBailey’s Branch, downstream of Tributaries 1 and 2.

• Tributary 4 – this stream is a first order tributary of Bailey’s Branch. The drainagebegins just east of Mt. Pleasant Road and flows west-southwest to join Bailey’sBranch downstream of Tributary 3.

• Tributary 5 – this stream is a first order tributary of Bailey’s Branch that includes twodrainages at its headwaters. The first drainage begins just north of BreckenridgeRoad (north of the GM plant). The second begins just southeast of the intersection ofDive and Peerless Roads. Both drainages come together west of Jackson Street andflow to the east-northeast to join Bailey’s Branch.

• Unnamed Western Tributary – this tributary of Salt Creek is a first order stream thatbegins to the west of the GM plant and joins Salt Creek northwest of the City ofBedford. Flow is generally to the west-northwest.

• Pleasant Run Creek – this stream is a minor tributary of Salt Creek. The headwatersof the main stem of Pleasant Run begin east of Mt. Pleasant Road, upstream ofBailey’s Branch. Flow is westerly through the Study Area to Salt Creek at thenorthwest limit of the Study Area. Pleasant Run Creek includes several tributariesother than Bailey’s Branch that drain areas other than from the GM Plant and areasnorth of Pleasant Run Creek.

• Salt Creek – this creek is a third order stream that is one of the main surface waterdrainage features within the East Fork White River Drainage Basin. Salt Creekenters the Study Area from the north and flows to the south along the western

Page 16: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 7 CONESTOGA-ROVERS & ASSOCIATES

portion of the Study Area to join the East Fork of the White River just southwest ofthe City of Bedford. Salt Creek is primarily fed by releases from Lake MonroeReservoir and by Clear Creek, as well as numerous tributaries, many larger thanPleasant Run Creek.

Page 17: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 8 CONESTOGA-ROVERS & ASSOCIATES

5.0 GENERAL STREAM CHARACTERISTICS

The following stream characteristics and habitat observations were made duringfloodplain and bank soil sample collection activities throughout the drainage area.

5.1 BAILEY’S BRANCH

The headwaters of Bailey’s Branch near Outfall 002 range in width from approximatelyone to three feet. This area of the drainage is comprised of bedrock outcrops andstreambed, gravel-sized sediment, and minimal areas of finer-grained depositionalsediments in isolated pools. A constant, perennial, base flow level exists in this channeldue to the GM Outfall 002 discharge. This flow is augmented by bedrock springs andsurface runoff. During dry conditions, the Outfall discharge constitutes most of theflow. Low flow water levels range from a few inches over exposed bedrock areas to oneto three feet in pools. This area is heavily vegetated with mature second growth.

The stream channel gradually increases in size downstream of Bailey’s Scales Road.Two abandoned quarry pits, now filled with standing water, are located approximately50 feet east of the stream channel, at a point approximately 1,000 feet downstream ofBailey Scales Road. Below the point where Bailey’s Branch and Tributary 3 merge, thestream channel width is approximately eight to ten feet and the average depth increasesfrom approximately two feet to four feet. Larger pools of water are present in this area.The stream channel consists of mostly bedrock, large cobbles and boulders, and fine tocoarse-grained sediments. A limited floodplain exists, which gradually increases to amaximum width of a few hundred feet near the confluence with Pleasant Run Creek.Vegetation in the floodplain is dense, with abundant undergrowth and mature secondgrowth. Some areas appear to have been historically cleared, though these haveapparently been fallow for many years based on interviews conducted with propertyowners.

There appears to be an area where a significant portion of the stream flow is diverted tochannels below the streambed. In one area, the surface water flow disappears beneaththe streambed via multiple openings in the streambed and banks, under lower flowconditions. This area is approximately 500 feet in length and is located near theboundary between private property and GM property immediately downstream of theconfluence of Tributary 3 with Bailey’s Branch.

Page 18: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 9 CONESTOGA-ROVERS & ASSOCIATES

5.2 TRIBUTARY 1

The Tributary 1 stream channel ranges in width from approximately one to three feet.This tributary is spring-fed at the source. The streambed consists primarily of bedrockand clay, with minimal depositional sediment. The stream channel contains a significantamount of leaf litter and small woody debris. Tributary 1 is an ephemeral streamflowing only in response to precipitation events. The vegetative cover in this areaconsists of mature second growth and limited undergrowth.

5.3 TRIBUTARY 2

The Tributary 2 stream channel ranges in width from approximately one to four feet.The streambed consists primarily of bedrock, with minimal to non-existent depositionalsediment. This stream is also ephemeral stream flowing only in response toprecipitation events. Surrounding vegetative cover is similar to that around Tributary 1.

5.4 TRIBUTARY 3

The stream channels in the two drainages which combine to form Tributary 3 ranges inwidth from approximately one to four feet. The streambed consists of a sandy-clay,bedrock streambed with minimal areas of fine-grained depositional sediments. Thestream flow is perennial. Vegetative cover is similar to those noted for Tributaries 1 and2.

5.5 TRIBUTARY 4

The stream channel of Tributary 4 ranges in width from approximately one to six feet.The streambed consists primarily of bedrock, with minimal depositional sediment.Generally, the stream channel is dry with a few stagnant pools in eroded areas in thebedrock streambed, similar to Tributary 2. Vegetative cover and flow are similar tothose noted for Tributaries 1 and 2.

5.6 TRIBUTARY 5

The stream channel of Tributary 5 ranges in width from approximately one to three feet.The streambed consists of fine-grained depositional sediments and bedrock. Vegetative

Page 19: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 10 CONESTOGA-ROVERS & ASSOCIATES

cover in this area consists of vegetated undergrowth, immature second growth, andminimal mature second growth. Generally, this stream is perennial and approximatelyone to three feet in depth. The stream channel contains garbage debris from illegaldumping. Some areas to the east of the stream channel appear to have been filled withmaterial including old limestone blocks and scrap metal.

5.7 PLEASANT RUN CREEK (STREAM 6)

Pleasant Run is a third order, lower gradient stream than Bailey’s Branch and tributaries.The total area of the Pleasant Run watershed is approximately 2,800 acres. Water levelsin Pleasant Run are highly dependent on precipitation, and have been observed tofluctuate dramatically in response to rainfall events. Under low flow conditions, thiscreek consists of widely spaced pools, typically ranging from 1 to 4 feet in depth. Underhigh flow conditions, the creek is one continuous run through most of its length, withcenter channel water depths of 6 to 10 feet. Significant floodplain areas are found here,extending as much as 1,000 feet in total width, and flooding has occurred in recent yearsat least as far upstream as the Mt. Pleasant Road bridge. Flooding was observed in May2002.

From the confluence with Bailey’s Branch and to the Peerless Road bridge, the gradientof Pleasant Run Creek decreases significantly and the bank height increases. The streamchannel is approximately eight to ten feet wide and the average depth of the streambanks increases from four to six feet over this reach. Streambed material in Pleasant Runconsists of fine to coarse gravel and soft clay and silt sediments. The finer materialappears to be derived from local bank erosion. Large woody debris is common, as ismaterial from dumping (e.g., old appliances, tires, etc.). The steep stream banksprimarily consist of clay and are partially vegetated by large trees. Most of thefloodplain has been historically cleared for cultivation, leaving only a narrow ripariancorridor along the stream banks. The small areas that have not been cleared are heavilyvegetated by mature second growth and lowland vegetation.

The Peerless Road Bridge is located at a constriction in the floodplain. Immediatelydownstream of Peerless Road, Pleasant Run Creek branches off into multiple channels,some of which only carry water during high flow periods. Many banks in this segmenthave historically been heavily eroded from cattle walking within the stream channel,although currently, there are no cattle in the floodplain of Pleasant Run Creek. The mostextensive floodplain in the drainage is between Peerless Road and the former MurdockStation location on the now abandoned Louisville and Nashville railroad.

Page 20: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 11 CONESTOGA-ROVERS & ASSOCIATES

Over this reach, the creek meanders, and numerous overflow channels exist in thefloodplain, some of which appear to have been filled and graded. The stream channel isapproximately six to twelve feet in width. Under low flow conditions, numerous poolsexist up to approximately four to six feet in depth and many are impounded by woodydebris. The streambed primarily consists of silty sediment and clay bottom. Thedrainage way is entirely constricted to the channel at the location where the formerrailroad bridge existed; a natural constriction in the floodplain being tightened by theconstructed railroad trestle over the stream. The floodplain in the lower watershedconsists primarily of cultivated and fallow agricultural fields and is heavily forested insome areas, especially near the confluence with Salt Creek.

5.8 UNNAMED WESTERN TRIBUTARY

The Unnamed Western Tributary is a very small, relatively high gradient, first orderstream ranging in width from approximately one to three feet. This drainage flows in awesterly direction through a residential area near the GM Plant. The streambed consistsof fine to coarse grain sediments, small to medium gravel and bedrock. Near the GMPlant, vegetation in the vicinity of the creek is typical of residential areas, much of itconsisting of maintained lawn. In the area further downstream near Salt Creek, thevegetation becomes dense with abundant under growth and mature second growthforest.

5.9 SALT CREEK

Salt Creek is a large, meandering tributary of the East Fork of the White River, withextensive floodplains. Most of the floodplain has historically been cleared forcultivation, leaving a narrow, well-developed riparian corridor along the creek.Significant mature woodlands exist along Salt Creek in some areas where the floodplainis narrow and bluffs exist along one or both banks. Over the reach of Salt Creek fromapproximately one-mile above to one mile below the confluence with Pleasant RunCreek, the stream channel is approximately 50 feet wide. The clay stream banks are verysteep, ranging from 6 to 20 feet in elevation. The streambed primarily consists of hardclay. Large woody debris is common, with logjams of very large uprooted treesblocking the entire stream channel under low flow conditions. Water levels in SaltCreek are highly variable, depending of precipitation and releases from the LakeMonroe reservoir. Extensive over bank flooding was observed in 2002.

Page 21: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 12 CONESTOGA-ROVERS & ASSOCIATES

6.0 SAMPLING RATIONALE

Based on data collected during the Phase I sampling, stream reconnaissance activities,map review, and consultation with the U.S. EPA and IDEM, the following samplingrationale was developed to meet the objective of the second phase of soil, sediment, andsurface water sample collection.

6.1 FLOODPLAIN AND BANK SOIL SAMPLING

Phase I Floodplain and Bank Soil Sampling Summary

Floodplain and bank soil sampling was performed during Phase I sampling in October2001, as summarized in the Bedford RFI Technical Memorandum 1, Stream InvestigationData Summary by Exponent. Soil samples were collected from the bank locations in theupper portion of the Study Area and floodplain transects were located perpendicular tothe stream channel in the lower Study Area watershed. Based on previous samplingactivity in October 2001, PCBs in soil were highest in Bailey’s Branch and its headwatertributaries.

Phase II Floodplain and Bank Soil Sampling Approach

Samples of floodplain and bank soil were collected along the Study Area streamsincluding the upper and lower portions of Bailey’s Branch from Outfall 002, UnnamedWestern Tributary, Tributaries 1, 2, 3, 4, 5; and Pleasant Run Creek (Stream 6). Sampleswere analyzed for PCBs by the U.S. EPA Method 8082. Severn-Trent Laboratories, Inc.(STL) in North Canton, Ohio performed analyses. QA/QC samples were collected fordata quality assessment in accordance with the RFI QAPP. Following receipt of finalanalytical data, the Quality Assurance Officer (QAO) prepared a separate data qualityassessment and validation memorandum that is available under separate cover.

Transects (lines of collected samples which were oriented approximately perpendicularto the stream flow) were spaced depending on the general elevation and layout of thelocal floodplain and topography. Soil samples collected along each transect were alsospaced depending on elevation and topography. Soil samples were collected at variousdepths to determine extent of contamination surficially and vertically; therefore, surficialsoil samples (0 to 4 inches) were collected at these stations and sub-surface samples (4 to24 inches) were collected across every fifth transect. In addition, further delineation wasbased on results from sampling activities performed in October 2001. The floodplainand bank soil sampling are further explained in Section 9.0.

Page 22: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 13 CONESTOGA-ROVERS & ASSOCIATES

In general, the density of soil sample locations was highest on Bailey’s Branch nearest toOutfall 002. Transect spacing (i.e., the distance between each transect) varied as afunction of distance from the GM Plant, increasing with distance from Outfall 002. Inthe upper reach of the Bailey’s Branch from Outfall 002 to Bailey Scales Road, transectswere spaced approximately every 100 feet apart. The spacing was increased to 200 feetover the reach from Bailey Scales Road to Broomsage Road. Downstream of BroomsageRoad, where significant widening of the floodplain occurs, transects were locatedapproximately every 500 feet. Samples were spaced along the lines of each transect toprovide coverage of the entire floodplain. In two locations, landscaped yard areas ofresidential properties were located within or partially within the floodplain.Higher-density, gridded sampling was conducted at these locations to fully characterizeareas with a higher potential for human exposure to soil. Higher-density soil samplingalso occurred below the Peerless Road bridge in the Pleasant Run Creek floodplain.

In various locations, soil sampling was also performed based on case-by-case analysis ofproperty owner’s requests. The soil sampling results are further discussed inSection 9.0.

6.2 SURFACE WATER/SEDIMENT SAMPLING

Phase I Surface Water and Sediment Sampling Summary

In order to investigate the relative significance of groundwater infiltration and/orstormwater overland flow to the Study Area stream as a potential secondary source ofPCB contamination, the 2001 Phase I Stream Investigation Work Plan prepared byExponent, specified collection of sediment samples and surface water samples duringperiods of both low and high rainfall. Due to preferential shallow groundwaterpathways, as well as overland sheetflow, it was noted that flow volume in many of theStudy Area streams is extremely responsive to rainfall events.

Surface water sampling was performed during Phase I sampling in October 2001, assummarized by Exponent, 2002. Surface water samples were collected from the upperand lower portions of Bailey’s Branch from the Outfall 002 to Bailey’s Branch of PleasantRun Creek, Pleasant Run Creek, headwater areas of the Unnamed Western Tributary,Tributary 3, and Tributary 5. Phase I sampling was conducted during a period ofextended dry weather under low-flow conditions. These original stations were thenresampled in May 2002 under high flow conditions after a period of extended wetweather.

Page 23: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 14 CONESTOGA-ROVERS & ASSOCIATES

Based on previous sampling activity in October 2001, PCBs in sediment were highest inBailey’s Branch and its headwater tributaries. PCB concentrations in sediments collectedin the lower reaches of Pleasant Run Creek were generally lower than in the upperreaches. Sediment collected from Salt Creek was found to contain much lower levels ofPCBs than those samples collected within Pleasant Run Creek. Similar levels weredetected at Salt Creek sample locations, extending approximately 1 mile both upstreamand downstream of the confluence with Pleasant Run Creek. Water and sedimentsamples collected from the upstream reach of Pleasant Run Creek and Gullets Creek didnot contain detectable levels of PCBs. Sediment was patchy and appears to be highlymobile throughout the Study Area (Exponent, 2002).

Generally, sediment samples were collected at every surface water sample location. Theobjective was to obtain a sediment sample from 0 to 4 inches (approximately 10centimeters). However, sediment depth in the Study Area streams is often less than4 inches. In such instances sediment samples were collected from the maximum depthinterval possible. In addition to sediment samples collected from the stream channelduring the initial Phase I stream sampling, sediment samples were collected from thetwo abandoned quarry pits, now filled with standing water, located approximately50 feet east of the stream channel, at a point approximately 1,000 feet downstream ofBailey Scales Road. Sediment samples were collected from the edge of the quarry pondsusing a clean stainless steel spoon. Sediment sample depths were 0 to 4 inches from theedge of the lower quarry pond (closest to Bailey’s Branch). The upper quarry pond wassampled during the Phase II Stream Sampling. Low levels of PCBs were detectedduring the Phase I sampling. The Phase I analytical results are summarized in theBedford RFI Technical Memorandum 1 - 2001 Stream Investigation Data Summary(Exponent, 2002).

Phase II Stream Sampling Approach

Surface Water Sampling

During Phase II of the stream investigation, additional surface water samples werecollected to further characterize Study Area tributaries and springs that were notsampled during the Phase I stream investigation. Additional surface water sampleswere also collected to assess and/or characterize various spring locations near formerOutfall 001 and former Outfall 003. An additional spring sample was collected north ofthe plant on private property and north of the landfill disposal area. The water sampleswere analyzed for Target Compound List (TCL) volatile organic compounds (VOCs),semivolatile organic compounds (SVOCs), PCBs, Target Analyte List (TAL) metals (less

Page 24: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 15 CONESTOGA-ROVERS & ASSOCIATES

earth metals), filtered PCBs, filtered metals, total cyanide, total Kjeldahl nitrogen,ammonia, pH, total suspended solids (TSS), total dissolved solids (TDS), andbicarbonate alkalinity. Table 6.1 presents the surface water results sample summary.

Extended periods of rainfall occurred during May of 2002, therefore, several surfacewater sample locations were resampled during this time. Phase II surface watersampling (January 2002–April 2002) and resampling (May 2002) was conducted duringwet and extremely wet periods, respectively. According to data from Purdue UniversityApplied Meteorology Group, the total rainfall over the four-month period from January2002 to April 2002 as measured in Bedford was 15.05 inches and the total rainfall in Maywas 11.20 inches. The total rainfall over a four-month period from June 2002 toSeptember 2002 as measured in Bedford was 8.19 inches. 1 Surface water samplescollected during the May 2002 resampling were analyzed for total and dissolved PCBs.

In addition to the above spring and tributary sampling, surface water samples werecollected on private property, per resident request. These locations included streams,springs, ponds, stormwater drainage areas, and surface water runoff areas. Table 6.2presents the surface water sample results summary.

Sediment Sampling

To further supplement the sediment sampling that occurred during the Phase I streamsampling, sediment samples were collected at every surface water sample locationwhere sediments were not previously collected. The objective was to obtain a sedimentsample from 0 to 4 inches. However, sediment depth in the Study Area streams is oftenless than 4 inches, and sometimes nonexistent. In such instances sediment samples werecollected from the maximum depth interval possible. In some locations, additionalsediment sampling was performed. Sediment samples were analyzed for PCBs, TOC,and grain size. Table 6.3 presents the sediment sample results summary.

In addition to sediment samples collected from the stream channel, additional sedimentsamples were collected from the two abandoned quarry pits during the Phase IIsampling. Sediment samples were collected from the center of the ponds using ahand-coring device. Sediment depths were 2 to 3 feet in the lower quarry pond (closestto Bailey’s Branch) and 16 to 18 inches in the upper pond. Samples of surface (0 to10 inches) and deeper sediments (10 to 20 inches) were collected. The sediment wasanaerobic, silty-sand at approximately 0 to 10 inches with clay below 10 inches. A slight

1 http://shadow.agry.purdue.edu/, accessed on July 16, 2002 and September 10, 2002.

Page 25: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 16 CONESTOGA-ROVERS & ASSOCIATES

organic sheen, typical of decaying plant material, was visible in some samples.Analytical results are summarized in Table 6.3.

Spring/Seep Sampling

Springs and seeps were characterized, identified and mapped to help evaluate potentialgroundwater migration pathways. The mapped springs and seeps had a perceivableflow during most of the dry weather. Areas where water was ‘seeping’ at the toe of aslope, such as at the base of the landfill or bottom of a fill area, were generally classifiedas seeps. Numerous other areas along the rocky slopes of the creek have flow duringwet weather. In some cases, additional spring samples were collected at the request ofproperty owners.

Surface water samples were also collected from perennial springs, which were alsomapped. (These perennial springs flowed immediately following a significant rainevent, but not at other times).

In some cases, springs that were originally sampled prior to May 2002, were submergedunder six to ten feet of water due to flooding conditions. These locations were notresampled.

During the extended period of rainfall that occurred in May 2002, spring locationspreviously sampled from January 2002 to April 2002 were resampled. The surface watersamples were analyzed for total and dissolved PCBs. The spring/seep locations arepresented on Figures 6.1 through 6.9.

Surface water samples were also collected from seep areas on the plant property. Inthose cases, water samples were analyzed for PCBs, metals, VOCs, SVOCs and generalchemistry. If present, color differences in the soil or the presence of sheen would benoted. Table 6.4 presents groundwater results for PCBs only. See Table 6.1 for otheranalytes. Analytical results for off-Site springs and seeps are summarized in Table 6.5.Analytical results for on-Site seep areas are summarized in Table 6.6.

Page 26: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 17 CONESTOGA-ROVERS & ASSOCIATES

7.0 SAMPLING PROCEDURES

CRA’s stream sampling activities followed the sampling procedures presented in theQAPP (CRA, 2001) and the FSP (Exponent, 2001). The QAPP and FSP detail items suchas the type of sample containers to be used, appropriate procedures for the collection ofsoil, sediment, groundwater and surface water samples, Quality Assurance/QualityControl (QA/QC) samples, custody procedures, instrument calibration,decontamination, and laboratory standard operation procedures (SOP).

Sampling procedures and equipment were amended for the collection of soil. Inaddition to using stainless steel spoons and bowls, CRA utilized stainless steel forestrysoil probes and slide hammers, hand augers, and a Geoprobe sampling system toachieve sampling at subsurface intervals. This equipment was decontaminated betweensample collection consistent with the QAPP and FSP.

A daily record of field activities was kept by the sampling team in bound field booksand on the Soil Sample Record Form detailing the day's activities. Upon completion ofthe field activities, receipt of final analytical results, and data quality assessment andvalidation, the results were summarized in an individual report for each separate parceland submitted to U.S. EPA and IDEM. Additionally, the data package generated foreach parcel that was sampled was hand delivered and explained to the resident (or tothe owner, if different than the current resident). The purpose of this memorandum is tosummarize all the data collected for the entire SA.

Page 27: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 18 CONESTOGA-ROVERS & ASSOCIATES

8.0 MAPPING AND LOCATION OF SAMPLES

Final sample locations were determined by using a global positioning system to achievelongitude and latitude coordinates as well as surface elevation. Coordinates providedare North American Datum (NAD) 1983 coordinates and USGS NAVD 88 benchmark atthe Virgil Municipal Airport.

Page 28: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 19 CONESTOGA-ROVERS & ASSOCIATES

9.0 STUDY AREA SAMPLE COLLECTION AND FINDINGS

The following section describes the general findings from this investigation includingsoil sampling (floodplain and resident request), sediment sampling, surface watersampling, and plant tissue sampling (January 2002 through August 2002). Section 9.0 isorganized by Study Area (refer to Section 4.2) for ease of data presentation. Additionalvertical delineation sampling in late July and August 2002 is summarized in Section 9.12.Post August 2002 sampling results will be presented in an Addendum to this TM. Thefollowing describes the sampling results of the individual Study Areas during the PhaseII sampling event.

9.1 STUDY AREA 1

Both water (spring and seeps) and soil samples were collected form Study Area 1.Transects (for the collection of soil samples) were located to the north of the formernorth disposal area and former equipment storage areas through a drainage area thatruns from the Plant property through a culvert under GM Drive (upper portion ofTributary 3). Transects were oriented perpendicular to the drainage area approximatelyevery 200 feet. The soil sample locations were based on local topography, as shown onFigure 9.1 - Stream Sample Locations - Study Area 1. The drainage valley and the extentof potential high water during rain events determined the location of the sample.Generally, soil samples were collected throughout the low-lying areas until the groundelevation increased away from the stream (as determined in the field visually). Theelevation change defined the end points of the transect. Additional samples werecollected if needed at higher elevations until the PCB contamination was delineated.

The spring and seep areas are located north of the landfill disposal area. These surfacewater samples from springs and seeps were analyzed for TCL VOCs, SVOCs, Total andDissolved PCBs, TAL metals (less earth metals), filtered PCBs, filtered metals, totalcyanide, total Kjeldahl nitrogen, ammonia, pH, TSS, TDS, and calcium carbonatehardness. Total PCBs were detected in the water samples collected from this area.Analytical results for total PCBs were 0.022 micrograms per Liter (µg/L), 0.180 µg/L,and 0.10 µg/L. Dissolved PCBs detections were 0.010 (J) µg/L (This reported laboratoryresult is qualified as an estimated value [J]), and 0.51 µg/L. The analytical results forTotal and Dissolved PCBs are summarized in Table 6.5, other analytes are summarizedin Table 6.1.

The Phase II surface water sampling program resulted in a range of results for totalPCBs between non-detect and 1.2 µg/L. Surface water results for dissolved PCBs range

Page 29: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 20 CONESTOGA-ROVERS & ASSOCIATES

between non-detect and 0.005 (J) µg/L. The reported laboratory result of 0.005 mg/L forthe dissolved results is qualified as an estimated value. Table 6.2 presents Phase IIsurface water sample results for total and dissolved PCBs only.

Soil samples were collected at a depth of 0 to 4 inches or until equipment refusal. In thisarea (Study Area 1), equipment refusal was frequently encountered at depths less than4 inches, especially near the stream banks. Additionally, portions of the area located onprivate property appeared to be fill material containing limestone mill blocks and debris.Generally, in this area, PCB concentrations in soil range from non-detect to 33 mg/kg.Table 9.1 presents the analytical results for soil.

9.2 STUDY AREA 2

Soil, sediment, surface water, and oil samples were collected from Study Area 2.Transects (for the collection of soil samples) on the upper portion of Bailey’s Branchbetween Outfall 002 and Bailey Scales Road includes high density sampling withinStudy Area 2. See Figure 9.2 – Stream Sample Location – Study Area 2A and Figure 9.3 –Stream Sample Location – Study Area 2B. Samples were collected at depths of 0 to4 inches at each sample location and 4 to 24 inches at sample locations across every fifthtransect or every 500 feet, where possible. Samples were also collected at depth from 4to 8 inches and 16 to 24 inches or until refusal for visual and selected laboratory analysis.See Figure 9.2 - Stream Sample Locations - Study Area 2A and Figure 9.3 - StreamSample Locations – Study Area 2B. The soil analytical results are summarized inTable 9.1.

The highest levels of PCBs in soil were detected in the area immediately downstream ofthe Outfall 002. Concentrations of PCBs at the 0 to 4 inch depth interval range from1.0 mg/kg to 9,900 mg/kg. Concentrations of PCBs at the 4 to 12 inch depth range from0.172 mg/kg to 860 mg/kg. Concentrations of PCBs in the 16 to 24 inch interval rangebetween 0.0083(J) mg/kg to 0.528 mg/kg (The reported laboratory result is qualified asan estimated value [J].).

Sediment samples were collected at surface water sample locations. Concentrations ofPCBs in sediment range from 157.8 mg/kg to 25,000 mg/kg. Concentrations of PCBs insurface water range from 0.515 (µg/L) to 0.87 µg/L.

On May 9, 2002, dense, non-aqueous phase liquid (DNAPL) was observed in thebedrock bottom of the stream channel within approximately 200 feet of Outfall 002. Asnoted above, this observation occurred during a particularly high rain event, and it is

Page 30: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 21 CONESTOGA-ROVERS & ASSOCIATES

believed that this unusual condition caused the DNAPL to mobilize from the bedrockand discharge into the creek due to hydrostatic pressure. Immediate containment andrecovery efforts were undertaken to address this issue.

Detailed Grid Sampling: At one property, where the landscaping extended to the creek,a higher density sampling grid was utilized for the collection of samples (in the frontand backyard of the residential property). See Figure 9.3 for Stream Sample Locations –Study Area 2B. Approximately 130 soil samples were collected. Transects were spacedat approximately 50-foot intervals in the front and backyard. Transects perpendicular tothe stream channel were spaced closer together for higher frequency sampling in 25-feetintervals. The analytical results of the soil samples collected from the front yard rangebetween non-detect and 0.012 mg/kg PCB. Results from Phase II soil samples collectedat the 0 to 4-inch depth interval in the backyard from the top of the slope behind theresidence to the creek range between non-detect and 650 mg/kg PCB. Results from soilsamples collected from the 4 to 8-inch depth interval range between non-detect and0.778 mg/kg PCB. Results from soil samples collected from the 8 to 12-inch depthinterval range between non-detect and 0.195 mg/kg PCB. Results from soil samplescollected from the 12 to 16-inch depth interval range between non-detect and0.0068(J) mg/kg PCB (This reported laboratory result is qualified as an estimated value[J]). A sheen was noticeable when water and bank soil were agitated in some areasalong the creek margins, although it is not clear what the nature of the sheen is. The soilanalytical results are summarized in Table 9.1. See Figure 9.2 and 9.3 for Stream SampleLocations – Study Areas 2A and 2B.

Additional soil samples were collected from residential properties located on BaileyScales Road per resident request. GM reviewed each request on a case-by-case basis andresponded to each accordingly. Interviews were conducted with the owners todetermine appropriate sample locations on the property. Generally in this area, soilsamples were collected from 0 to 4 inches from the front and backyards of the property.In a few instances, soil samples were collected from the garden. Table 9.1 presents theanalytical results summary for soil samples.

Exponent collected surface water samples in Study Area 2 during high water conditionsin May 2002. Surface water samples were analyzed for total and dissolved PCBs, metals,VOCs, SVOCs, and general chemistry. The objectives for this sampling are summarizedin the Stream Investigation Work Plan (Exponent, 2001).

Page 31: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 22 CONESTOGA-ROVERS & ASSOCIATES

9.3 STUDY AREA 3

Soil samples were collected within Study Area 3. In the area along Bailey’s Branchbetween Bailey Scales Road and Broomsage Road, transects were spaced approximatelyevery 200 feet. The sampling depth was 0 to 4 inches or until refusal. In addition tosurficial soil (0 to 4 inches), samples were collected at depth (4 to 24 inches) across everyfifth transect, or approximately every 1,000 feet. See Figure 9.4 - Stream SampleLocations - Study Area 3A and Figure 9.5 - Stream Sample Locations – Study Area 3B.

Soil samples collected from the 0 to 4-inch depth interval range from non-detect to264 mg/kg PCB and those from the 4 to 24-inch depth interval range from non-detect to171 mg/kg PCB. Bank soil, sediment and surface water samples were collected fromupstream Tributaries 2 and 4 of Bailey’s Branch from the Outfall 002 to Broomsage Road.Analytical results indicated that these tributaries did not contain detectable levels ofPCBs. The analytical results are summarized in Table 9.1.

One of the parcels in this Study Area is located in the floodplain of the lower portion ofBailey’s Branch at Broomsage Road, Mile Post 3.988. See Figure 1.3 for Mile Post andTributary Identification. Due to the nature of historical flooding conditions and thelocation of a residence proximate to the stream, a higher density sampling grid wasutilized in this location. Approximately 100 soil samples were collected in this area.Transects were spaced approximately every 50 feet perpendicular to the stream. Alongeach transect, sample locations were spaced approximately every 25 feet. Samples werecollected at depths of 0 to 4 inches or until refusal. At approximately every 500 feet, soilsamples were also collected at deeper intervals in addition to 0 to 4 inches (4 to 24 inchesand 24 to 48 inches). Samples collected from 0 to 4 inches range from non-detect to253 mg/kg PCB. Samples collected from 4 to 24 inches range from 0.94 to 111 mg/kgPCB and samples collected from 24 to 48 inches range between 0.175 to 73.2 mg/kg PCB.Figure 9.5 - Stream Sample Locations - Study Area 3B shows the locations of the area ofmore detailed floodplain soil sampling. The analytical results are summarized inTable 9.1.

Additional soil samples were collected from a nearby property upon resident request.See Figure 9.5 - Stream Sample Locations - Study Area 3B for those soil sample locations.Soil samples were collected from the front and backyard location from 0 to 4 inches.Analytical results are summarized in Table 9.1.

Page 32: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 23 CONESTOGA-ROVERS & ASSOCIATES

9.4 STUDY AREA 4

Soil, sediment and surface water samples were collected from Study Area 4. AlongBailey’s Branch, from Broomsage Road to its confluence with Pleasant Run, transectswere located at variable intervals due to widening of the floodplain. In the areabeginning at Broomsage Road and proceeding downstream approximately 1,000 feet,transects were spaced approximately every 200 feet. Every fifth transect, orapproximately 1,000 feet, soil samples were collected at depths of 0 to 4 inches and 4 to24 inches or until refusal. See Figure 9.6 Stream Sample Locations - Study Area 4A andFigure 9.7 - Stream Sample Locations – Study Area 4B. Soil samples collected from the 0to 4-inch depth interval range from non-detect to 179 mg/kg and those from the 4 to24-inch depth interval range from non-detect to 92.5 mg/kg.

At the confluence of Bailey’s Branch and Pleasant Run Creek, additional samples werecollected at deeper intervals (4 to 24 inches and 24 to 48 inches). Soil sample results from0 to 4 inches range from non-detect to 0.08 mg/kg, from 4 to 24 inches range fromnon-detect to 0.039(J) mg/kg and from 24 to 48 inches were non-detect for PCBs (Thisreported laboratory result is qualified as an estimated value [J]).

At the confluence of Bailey’s Branch and Pleasant Run Creek, the floodplain begins tonoticeably widen. Transects were located approximately every 500 feet to theconfluence of Pleasant Run Creek. Every fifth transect, or 1,000 feet, soil samples werecollected at depths of 0 to 4 inches and 4 to 24 inches or until refusal. The floodplain isapproximately 1,000 feet wide near the confluence of Pleasant Run Creek.

Additional soil samples were collected from a property in this Study Area per residentrequest in the front yard proximate to the stream channel (Pleasant Run Creek). Soilsamples were collected from 0 to 4 inches. Soil samples were non-detect for PCBs andare summarized in Table 9.1.

Phase II surface water and sediment samples were collected from locations upstream ofthe confluence of Bailey’s Branch and Pleasant Run Creek to Mount Pleasant Road.Sediment results for PCBs range from non-detect to 0.13 mg/kg. Surface water from thestream and identified springs in Study Area 4 range from non-detect to 0.001 µg/L totalPCBs. Table 6.4 presents PCB data for surface water samples.

Page 33: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 24 CONESTOGA-ROVERS & ASSOCIATES

9.5 STUDY AREA 5

Soil and water (spring) samples were collected from Study Area 5. Along Pleasant RunCreek, from the confluence with Bailey’s Branch to Peerless Road, transects were spacedapproximately every 500 feet perpendicular to the stream. Every fifth transect, orapproximately every 2,500 feet, samples were collected at deeper intervals (4 to 24 inchesor until refusal). See Figure 9.8 - Stream Sample Locations - Study Area 5. Soil samplescollected from 0 to 4 inches range from non-detect to 34.5 mg/kg and from 4 to 24 inchesrange from non-detect to 12.3 mg/kg. The floodplain ranges from approximately 500 to1,000 feet wide in this area. The analytical results are summarized in Table 9.1.

Additional soil samples were collected on two properties in this Study Area, as shownon Figure 9.8 - Stream Sample Locations - Study Area 5, upon resident request in thebackyards of the properties. Soil samples were collected from 0 to 4 inches. Resultsindicated non-detect for PCBs. Analytical results are summarized in Table 9.1.

Several springs were identified and sampled in Study Area 5 for total and dissolvedPCBs during low and high flow sampling conditions. The springs were located athigher elevations near the Pleasant Run floodplain. Spring sample analytical resultswere non-detect during both sampling periods (high and low flow). Spring samples aresummarized on Table 6.5.

9.6 STUDY AREA 6

Soil and sediment samples were collected from Study Area 6. In the floodplain locatedalong Pleasant Run Creek between Peerless Road and the former Murdock Station,Phase II transects were spaced approximately every 1,000 feet. At every third transect,or approximately 3,000 feet, soil samples were collected at deeper intervals (4 to24 inches or until refusal). See Figure 9.9 - Stream Sample Locations - Study Area 6.Analytical results for soil samples from the 0 to 4 inch depth interval ranges fromnon-detect to 35.5 mg/kg and the 4 to 24 inch depth interval ranges from 0.35 mg/kg to130 mg/kg.

In the oxbow (former stream channel, now mostly cut off from the main stream flow)areas of Pleasant Run Creek, transects were spaced approximately every 500 feetdepending on local topography, as shown on Figure 9.9. During low flow conditions,the oxbows have shallow stagnant pools of water and are often dry. During higher flowconditions, the oxbow holds approximately 5 to 6 feet of water. Sediment samples werealso collected from the oxbow area located in the Salt Creek floodplain. Sediment

Page 34: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 25 CONESTOGA-ROVERS & ASSOCIATES

samples range from 0.72 mg/kg to 12.1 mg/kg PCBs. Table 9.1 presents analytical soilsample results and Table 6.3 presents sediment sample analytical results.

9.7 STUDY AREA 7

Soil and crop samples were collected from Study Area 7. Along Pleasant Run Creekbetween the former Murdock Station and Salt Creek, transects were spacedapproximately every 1,000 feet. Samples were collected at depths of 0 to 4 inches and 4to 24 inches in an area approximately 1,000 feet upstream from Salt Creek on PleasantRun Creek. See Figure 9.10 - Stream Sample Locations - Study Area 7.

Analytical results for soil samples from 0 to 4 inches range from non-detect to0.501 mg/kg. Soil samples from 4 to 24 inches were non-detect. Sediment samples werecollected from two depressions in the floodplain. The two depressions contain standingwater at depths of approximately three feet. These depressions are located in the SaltCreek floodplain approximately 500 to 700 feet east of Salt Creek. Analytical results forthe sediment samples range between 0.1 mg/kg and 0.462 mg/kg. Table 6.3summarizes analytical data for this Study Area.

Corn samples were collected from corn stored in silage bins and from a cornfield locatedin the Pleasant Run Creek floodplain. Corn and soybeans are grown, rotating cropsbetween fields on one property in this Study Area. The property on the east side of SaltCreek, south of the Peerless Road Bridge is also farmed within the Salt Creek floodplain,approximately 1 mile north of the confluence of Pleasant Run Creek with Salt Creek.

Exponent and CRA visited the farmed fields on two different properties and walked theproperty near the stream. The corn was harvested, and the stalks had been trimmeddown to the ground surface. The roots of the stubble remained in the soil. The accessroad entered the property from the south in East Oolitic, and goes north through thegate to the abandoned rail trestle over Pleasant Run Creek at Murdock. Based on visualfield inspection, the lowest field that appeared the wettest was located south of thetrestle and abuts the neighboring property. CRA and Exponent obtained four cornsamples (this is dried corn, still on the cob, with partial husk still on, that was lying inthe field on the ground) at various distances from the east property line. CRA alsocollected soil samples at each location where a corn ear was obtained from the ground.

Each ear of corn was split in half by the laboratory. The laboratory then rinsed one halfof the ear (as corn is not harvested off the ground and this corn had been laying in thedirt), removed the kernels, and analyzed the kernels for PCBs. The corn samples were

Page 35: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 26 CONESTOGA-ROVERS & ASSOCIATES

non-detect for PCBs. Plant tissue analytical data is summarized in Table 9.2. The otherhalf of the ear of corn was archived.

Additional soil samples were collected from the property adjacent to the farm fieldproperty upon resident request. Soil samples were collected from the perimeter of aswimming pool because soil from the floodplain had reportedly been brought to thisarea. Soil samples were collected from 0 to 4 inches. Analytical results indicated thatthe soil samples were non-detect for PCBs. Analytical data is summarized in Table 9.1.

Hay (alfalfa) samples were also collected from this property. Samples were taken fromeach barn that contained stored hay and alfalfa and bails of hay that remained in thefarmed fields. The samples were sent to the laboratory in 9-ounce jars and wereanalyzed for PCBs. Plant analytical data indicated PCBs on the unwashed hay andalfalfa between 0.011 mg/kg and 0.022 mg/kg as summarized in Table 9.2. Low levelsof PCBs detected in the hay are likely attributable to soil particles entrained in the haywhen it was harvested.

9.8 STUDY AREA 8

In the area of the Unnamed Western Tributary closest to the GM Plant, bank soil, surfacewater, and sediment samples were collected. Transects were not located along thewestern tributary due to the unlikely event of flooding to occur. Based on fieldobservation, this watershed appears to have less significant discharge than the mainstream channels (Bailey’s Branch and Pleasant Run) and does not receive plantdischarge. (Some stormwater runoff from the western side of the plant property maycontribute to the western tributary). See Figure 9.11 - Stream Sample Locations - StudyArea 8.

The Unnamed Western Tributary has two source areas. The primary source isspring-fed. In addition to the primary source, a drainage swale and culvert appears totransfer surface water to the Unnamed Western Tributary from the southeast corner ofthe property located at the headwaters (Figure 9.11). The drainage swale originatesfrom a retention wall between the Plant and the property. Surface water samples aresummarized in Tables 6.1 and 6.2.

Surficial soil samples were collected on this property at a depth of 0 to 4 inches on bothsides of the stream channel. In Study Area 8, surficial soil analytical results range fromnon-detect to 2.34 mg/kg PCBs. Sediment sample analytical results range from0.249 mg/kg to 1.27 mg/kg PCBs. Surficial soil samples were collected from the area

Page 36: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 27 CONESTOGA-ROVERS & ASSOCIATES

around the retention wall and throughout the drainage swale. Soil sample analyticalresults for this area range between 1.37 mg/kg and 47.9 mg/kg PCBs. The analyticalresults are summarized in Table 9.1.

Additional soil samples were collected from the private property at the headwatersupon resident request based on previous data indicating PCB detections in soil sampleslocated on the property. See Figure 9.11 - Stream Sample Locations - Study Area 8 forsoil sample locations. Soil samples were also collected from a location on Third Streetbordering this property. Soil samples were collected on the Third Street location from 0to 4 inches. Analytical results for PCBs in soil on the Third Street property range from0.024 mg/kg to 0.29 mg/kg PCBs. The analytical results are summarized in Table 9.1.

9.9 STUDY AREA 9

From the most western portion of the Unnamed Western Tributary to its confluencewith Salt Creek sample stations were comprised of bank soil, sediment, and a surfacewater sample. Surficial soil samples were collected at a depth of 0 to 4 inches from bothsides of the stream channel. See Figure 9.12 Stream Sample Locations - Study Area 9.Phase II soil sample analytical results ranged from non-detect to 0.477 mg/kg PCBs.Phase II sediment sample analytical results ranged from 0.029 mg/kg to 0.049 mg/kgPCBs. Phase II surface water samples were non-detect for total and dissolved PCBs inthis portion of the stream.

The analytical results for soil, sediment, and surface water samples are presented inTables 6.2, 6.3 and 9.1, respectively.

9.10 STUDY AREA 10

In the area along the Tributary 5, bank soil, sediment and surface water and homegrownvegetable samples were collected. The headwater of Tributary 5 has two areas wherewater enters the tributary. One area is a spring located north of the Plant contractorentrance and driveway to the Plant. The flow increases downstream from otherspring-fed source locations. The other source of these headwaters is a spring locatedalong a closed access road. This drainage originates from a culvert and seeping water atthe base of the slope on the east side of the closed access road. Reportedly, a potentialfill area is located in this Study Area. The fill area is currently being evaluated. SeeFigure 9.13 - Stream Sample Locations - Study Area 10.

Page 37: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 28 CONESTOGA-ROVERS & ASSOCIATES

Samples were collected from a spring located in this Study Area north of the Plant onprivate property. The water was analyzed for TCL VOCs, TCL SVOCs, PCBs, TALmetals (less earth metals), filtered PCBs, filtered metals, total cyanide, total Kjeldahlnitrogen, ammonia, pH, TSS, TDS and calcium carbonate hardness. Analytical resultsare summarized in Table 6.5 and 6.6.

Based on field observation, this watershed appears to have less significant dischargethan the main stream channels (Bailey’s Branch and Pleasant Run Creek), therefore,transects were located in areas of the drainage that appeared to exhibit possible signs offlooding (i.e., wider, low-lying areas). Along Tributary 5, debris was observed in theeroding banks of the stream. See Figure 9.13a for locations of the noted debris.

Surficial soil samples were collected at a depth of 0 to 4 inches next to the creek.Analytical results for soil samples range between non-detect to 4.76 mg/kg PCBs.Sediment and surface water samples were also collected in the stream channel.Sediment analytical results range from 0.01 mg/kg to 3.68 mg/kg PCBs. Surface wateranalytical results for total PCBs range from non-detect to 0.016 (J) µg/L. In addition tothe channel flow, a surface water sample was collected and for PCBs from a springlocated just upstream of Broomsage Road. These analytical results were non-detect forPCBs.

Additional soil samples were collected upon resident request from several residentialproperties on North Jackson Street. Soil samples were collected from 0 to 4 inches andresults range from non-detect to 0.392 mg/kg.

Soil samples were also collected upon resident request from residents on Redbud Lanejust north of the GM Plant. See Figure 9.13 - Stream Sample Locations - Study Area 10.Soil samples were collected from 0 to 4 inches and range as with most in this area andNorth Jackson Street.

Canned bean and tomato samples were also collected from a resident located on RedbudLane. The resident was concerned with produce that was canned from his garden fromthe previous year. The resident gave CRA two 1-quart Mason Canning Jars. One hadstewed tomatoes and the other had green beans packed in water. Both jars appeared tobe in good condition with the vacuum seal intact. The Mason Canning Jars were sent tothe laboratory for analysis. Samples were analyzed for PCBs. Analytical results werenon-detect for PCBs. The analytical results are summarized in Table 9.2.

The analytical results for soil, sediment, surface water, and plant tissue samples arepresented in Tables 6.2, 6.3, 9.1, and 9.2, respectively.

Page 38: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 29 CONESTOGA-ROVERS & ASSOCIATES

9.11 STUDY AREA 11

This Study Area represents soil and surface water sampling performed in response toresidential requests. No transects were sampled in Study Area 11. Soil samples werecollected from a location on Oolitic Road and Cedar Avenue. Soil sample results werenon-detect for PCBs. The surface water sample was collected from a culvert drainagearea on Peerless Road. Surface water results were non-detect for PCBs. See Figure 9.14 -Stream Sample Locations - Study Area 11.

The analytical results for soil, sediment, and surface water samples are presented inTables 6.2, 6.3, and 9.1, respectively.

9.12 SUPPLEMENT VERTICAL DELINEATION SAMPLING

Additional soil samples were collected in July 2002 and August 2002 by CRA at therequest of GM to further delineate PCB contamination vertically and to define the limitsof surficial and subsurface impacts. Soil samples were collected in areas of the streamsand floodplain that required further delineation based on data review from the previousPhase II stream sampling activity. Soil samples were collected from 0 to 4 inches, 4 to12 inches, 12 to 18 inches, 18 to 24 inches, 24 to 36 inches, and 36 to 48 inches or untilequipment refusal.

In general, samples were collected using hand-held soil probes and spoons. For samplelocations that were accessible, track-mounted hydraulic-push sampling equipment wasutilized to achieve sampling at depth (24 to 36 inches and 36 to 48 inches).

In Study Area 3, soil sample analytical results from the 0 to 4-inch depth interval rangebetween 0.95 mg/kg to 45 mg/kg and from the 4 to 12-inch depth interval range from0.519 to 63 mg/kg. Soil samples collected from 12 to 18-inch depth interval range fromnon-detect to 1,010 mg/kg. Soil samples collected from 18 to 24-inch depth intervalrange from non-detect 190 mg/kg. PCBs are present at depth in this Study Area.Table 9.1 presents the analytical soil sample results.

In Study Area 4, along Bailey’s Branch, additional soil samples were collected intransects from 0 to 4 inches, 4 to 12 inches, 12 to 18 inches and 18 to 24 inches. At threeisolated locations, samples were collected also from 24 to 36 inches and 36 to 48 inches.Soil sample analytical results for PCBs from the 0 to 4-inch depth interval range from

Page 39: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 30 CONESTOGA-ROVERS & ASSOCIATES

non-detect to 140 mg/kg; sample results from the 4 to 12-inch depth interval range fromnon-detect to 250 mg/kg; sample results from the 12 to 18-inch depth interval rangefrom non-detect to 37.9 mg/kg; sample results from the 18 to 24-inch depth intervalrange from non-detect to 2.9 mg/kg; sample results from the 24 to 36 inch depth intervalrange from 0.049 mg/kg to 2.76 mg/kg; and sample results from the 36 to 48 inch depthinterval range from 0.29 mg/kg to 7.28 mg/kg. Table 9.1 presents the analytical soilsample results.

Additional surficial soil sample locations were sampled in the Pleasant Run floodplainimmediately downstream (east) of the Peerless Road bridge in Study Area 5. Generally,analytical results of PCBs for soil samples from the 0 to 4-inch depth interval range from2.8 mg/kg to 61 mg/kg. Soil sample results of PCBs from the 4 to 12-inch depth intervalrange from 0.44 mg/kg to 450 mg/kg; sample results from the 12 to 18-inch depthinterval range from non-detect to 61.7 mg/kg; and, sample results from the 18 to 24-inchdepth interval range from non-detect to 30 mg/kg. Table 9.1 presents the analytical soilsample results. At one location immediately downstream of the Peerless Road Bridge,soil samples were collected from 24 to 36 inches and 36 to 48 inches. Both intervals werenon-detect for PCBs.

In Study Area 6, just downstream (west) of Peerless Road bridge, additional soil sampleswere collected from 0 to 4 inches, 4 to 12 inches, 12 to 18 inches, 18 to 24 inches, 24 to36 inches and 36 to 48 inches. Analytical results of PCBs from the 0 to 4-inch depthinterval range from non-detect to 15.4 mg/kg; sample results from the 4 to 12-inch depthinterval range from non-detect to 5.23 mg/kg; sample results from the 12 to 18-inchdepth interval range from non-detect to 1.8 mg/kg; and, sample results from the 18 to24-inch depth interval range from non-detect to 0.405 mg/kg. At one location soilsamples were collected from depths of 24 to 36 inches and 36 to 48 inches. From24 inches to 36 inches, analysis indicated non-detect for PCBs; and from the 36 to48 inches, analysis indicated 0.0091(J) mg/kg (The reported laboratory result is qualifiedas an estimated value.).

Further downstream on Pleasant Run, additional samples were collected in StudyArea 7. Samples were collected from 0 to 4 inches, 4 to 12 inches, 12 to 18 inches andfrom 18 to 24 inches. Analytical results of PCBs from the 0 to 4-inch depth interval rangebetween non-detect to 1.4 mg/kg, from the 4 to 12 inch depth interval range fromnon-detect to 2.1 mg/kg; sample results from the 12 to 18-inch depth interval range fromnon-detect to 9.4 mg/kg; and, sample results from the 18 to 24-inch depth interval rangefrom non-detect to 1.2 mg/kg.

Page 40: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 31 CONESTOGA-ROVERS & ASSOCIATES

10.0 SUMMARY OF DATA ALONG MAIN STREAM SYSTEM

Based upon all sampling activities in the aforementioned sections of this TM, PCBisoconcentration maps have been developed along the main stream system impacted byhistoric wastewater discharges for each of the depth intervals sampled. The mainstream system impacted by historic wastewater discharge is comprised of SA’s 2, 3, 4, 5,6, and 7. (For purposes of this TM, there are no PCB isoconcentration maps for 1, 8, 9, 10and 11 because the maps indicate PCB concentrations equal to or greater than 2.2 ppmand equal to and greater than 50 ppm.)

These PCB isoconcentration key maps are presented on the following figures:

• Figure 10.1 - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Key Map;

• Figure 10.8 - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Key Map;

• Figure 10.15 - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Key Map; and

• Figure 10.22 - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Key Map.

The PCB isoconcentration maps for Study Area 2 are presented on the following figures:

• Figure 10.2 - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Study Area 2;

• Figure 10.9 - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Study Area 2;

• Figure 10.16 - PCB Isoconcentrations – 1-1.5 Sampling Interval, Study Area 2; and

• Figure 10.23 - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Study Area 2.

The PCB isoconcentration maps for Study Area 3 are presented on the following figures:

• Figure 10.3a - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Study Area 3A;

• Figure 10.3b - PCB Isoconcentrations – 0-3.3’ Sampling Interval, Study Area 3B;

• Figure 10.10a - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Study Area 3A;

• Figure 10.10b - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Study Area 3B;

• Figure 10.17a - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Study Area 3A;

• Figure 10.17b - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Study Area 3B;

• Figure 10.24a - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Study Area 3A; and

• Figure 10.24b - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Study Area 3B.

The PCB isoconcentration maps for Study Area 4 are presented on the following figures:

Page 41: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 32 CONESTOGA-ROVERS & ASSOCIATES

• Figure 10.4 - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Study Area 4;

• Figure 10.11 - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Study Area 4;

• Figure 10.18 - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Study Area 4; and

• Figure 10.25 - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Study Area 4.

The PCB isoconcentration maps for Study Area 5 are presented on the following figures:

• Figure 10.5 - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Study Area 5;

• Figure 10.12 - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Study Area 5;

• Figure 10.19 - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Study Area 5; and

• Figure 10.26 - PCB Isoconcentrations – 1.5-2’ Sampling Interval Study Area 5.

The PCB isoconcentration maps for Study Area 6 are presented on the following figures:

• Figure 10.6 - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Study Area 6;

• Figure 10.13 - PCB Isoconcentrations – 0.33-1’ Sampling Interval, Study Area 6;

• Figure 10.20 - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Study Area 6; and

• Figure 10.27 - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Study Area 6.

The PCB isoconcentration maps for Study Area 7 are presented on the following figures:

• Figure 10.7 - PCB Isoconcentrations – 0-0.33’ Sampling Interval, Study Area 7;

• Figure 10.14 - PCB Isoconcentrations – 0.33-1’ Sampling Interval. Study Area 7;

• Figure 10.21 - PCB Isoconcentrations – 1-1.5’ Sampling Interval, Study Area 7;

• Figure 10.28 - PCB Isoconcentrations – 1.5-2’ Sampling Interval, Study Area 7; and

Refer to Figures 10.29 and 10.30 for the key maps for PCB Isoconcentrations from 2-3’and 3-4’ Sampling Intervals.

Page 42: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 33 CONESTOGA-ROVERS & ASSOCIATES

11.0 QUALITY ASSURANCE QUALITY CONTROL

The stream sample results were validated according to the requirements of theSite-specific QAPP. The precision, accuracy, representativeness, and completeness ofthe laboratory analytical data were evaluated consistent with the relevant and applicablerequirements of U.S. EPA's data review guidance document entitled "USEPA ContractLaboratory Program National Functional Guidelines for Organic Data Review" (EPA540/R-99/008, October 1999).

Data evaluation included reviewing sample holding time periods, initial calibrationdata, calibration verification data, method blank data, surrogate compound spike data,laboratory control sample data, matrix spike/matrix spike duplicate sample data,analyte identification, and analyte quantitation. In addition, the data from field qualitycontrol samples (i.e., field blank and field duplicate samples) collected during thesampling event were evaluated to access the overall precision and accuracy of thesampling and analysis effort. The results of the validation procedure indicated that thedata are usable for the intended purposes of the project. A summary of the dataincluding all data validation will be submitted as a separate TM.

Page 43: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

013968 (32) 34 CONESTOGA-ROVERS & ASSOCIATES

12.0 REFERENCES

Conestoga-Rovers and Associates, 2002, Upstream Parcels Interim Measures Work PlanPursuant to 40 CFR 761.61 (c)

Conestoga-Rovers and Associates, 2001, Quality Assurance Project Plan

Exponent Inc., 2001, Stream Investigation Work Plan

Exponent Inc., 2001, Stream Investigation Field Sampling Plan

Exponent Inc., 2002, Bedford RFI Technical Memorandum 1, 2001 Stream InvestigationData Summary

Purdue University Agriculture, http://shadow.agry.purdue.edu, 2002

Page 44: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.1

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES

Page 1 of 6

Sample Location: Seep 5013 5041 5042 5043 5044 5045 5045Sample ID: SW-052902-JW-5013 SW-052102-JW-5041 SW-052102-JW-5042 SW-052102-JW-5043 SW-052102-JW-5044 SW-052202-JW-5045 SW-052202-JW-5045ASample Date: 5/29/2002 5/21/2002 5/21/2002 5/21/2002 5/21/2002 5/22/2002 5/22/2002

Duplicate

Parameter Unit

Metals (Total)

Aluminum mg/L 1.3 ND (0.2) 56.2 16.8 ND (0.2) 0.034 J 0.034 JAntimony mg/L ND (0.06) ND (0.06) 0.0043 J 0.0042 J 0.011 J ND (0.06) ND (0.06) Arsenic mg/L ND (0.01) ND (0.01) 0.081 0.27 ND (0.01) ND (0.01) ND (0.01) Barium mg/L 0.26 0.06 J 0.89 0.66 0.034 J 0.045 J 0.044 JBeryllium mg/L ND (0.005) ND (0.005) 0.0014 J 0.00097 J ND (0.005) ND (0.005) ND (0.005) Cadmium mg/L ND (0.005) ND (0.005) ND (0.005) 0.0023 J ND (0.005) ND (0.005) ND (0.005) Chromium mg/L 0.0036 J ND (0.01) 0.087 0.022 ND (0.01) ND (0.01) ND (0.01) Cobalt mg/L ND (0.05) 0.0024 J 0.12 0.044 J ND (0.05) ND (0.05) ND (0.05) Copper mg/L ND (0.025) ND (0.025) 0.38 0.37 0.01 J 0.0066 J 0.0058 JCyanide (amenable) mg/L ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) Iron mg/L 42.6 1.4 306 538 ND (0.1) 0.14 0.12 Lead mg/L 0.0041 ND (0.003) 0.067 0.035 ND (0.003) ND (0.003) ND (0.003) Manganese mg/L 3.1 1.2 57.4 29.4 0.0083 J 0.03 0.024 Mercury mg/L 0.00044 ND (0.0002) 0.00058 0.00012 J ND (0.0002) ND (0.0002) ND (0.0002) Nickel mg/L ND (0.04) 0.0038 J 0.15 0.048 ND (0.04) ND (0.04) ND (0.04) Selenium mg/L ND (0.005) ND (0.005) ND (0.025) ND (0.005) ND (0.005) ND (0.005) ND (0.005) Silver mg/L ND (0.01) ND (0.01) 0.0031 J ND (0.01) ND (0.01) ND (0.01) ND (0.01) Thallium mg/L ND (0.001) ND (0.001) ND (0.001) ND (0.001) ND (0.001) ND (0.001) ND (0.001) Vanadium mg/L 0.0022 J ND (0.05) 0.096 0.019 J ND (0.05) ND (0.05) ND (0.05) Zinc mg/L 0.1 ND (0.02) 0.42 0.26 0.027 0.014 J ND (0.02)

Metals (Dissolved)

Aluminum (Dissolved) mg/L ND (0.2) U ND (0.2) ND (0.2) 0.058 J ND (0.2) ND (0.2) ND (0.2) Antimony (Dissolved) mg/L ND (0.06) ND (0.06) ND (0.06) ND (0.06) 0.013 J ND (0.06) ND (0.06) Arsenic (Dissolved) mg/L ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) Barium (Dissolved) mg/L 0.25 0.059 J 0.093 J 0.055 J 0.036 J 0.045 J 0.047 JBeryllium (Dissolved) mg/L ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) Cadmium (Dissolved) mg/L ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) Chromium (Dissolved) mg/L 0.002 J ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) Cobalt (Dissolved) mg/L ND (0.05) 0.0023 J ND (0.05) 0.0018 J ND (0.05) ND (0.05) ND (0.05) Copper (Dissolved) mg/L ND (0.025) ND (0.025) ND (0.025) ND (0.025) 0.0076 J 0.0053 J 0.0064 JCyanide (total) mg/L ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) Iron (Dissolved) mg/L 39.9 1.2 ND (0.1) 0.1 ND (0.1) ND (0.1) ND (0.1) Lead (Dissolved) mg/L ND (0.003) ND (0.003) ND (0.003) ND (0.003) ND (0.003) ND (0.003) ND (0.003) Manganese (Dissolved) mg/L 3.1 1.2 0.71 1.3 0.0041 J 0.025 0.025 Mercury (Dissolved) mg/L 0.00034 ND (0.0002) ND (0.0002) ND (0.0002) ND (0.0002) ND (0.0002) ND (0.0002) Nickel (Dissolved) mg/L ND (0.04) 0.0038 J ND (0.04) ND (0.04) ND (0.04) ND (0.04) ND (0.04) Selenium (Dissolved) mg/L ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) ND (0.005) Silver (Dissolved) mg/L ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) ND (0.01) Thallium (Dissolved) mg/L ND (0.001) ND (0.001) ND (0.001) ND (0.001) ND (0.001) ND (0.001) ND (0.001) Vanadium (Dissolved) mg/L ND (0.05) ND (0.05) ND (0.05) ND (0.05) ND (0.05) ND (0.05) ND (0.05) Zinc (Dissolved) mg/L 0.013 J ND (0.02) ND (0.02) ND (0.02) 0.028 ND (0.02) ND (0.02)

PCBs

Aroclor-1016 (PCB-1016) ug/L ND (0.2) ND (1) ND (1) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1221 (PCB-1221) ug/L ND (0.2) ND (1) ND (1) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1232 (PCB-1232) ug/L ND (0.4) ND (2) ND (1) UJ ND (0.4) ND (0.4) ND (0.4) ND (0.4) Aroclor-1242 (PCB-1242) ug/L ND (0.2) 12 ND (1) UJ 2.1 0.97 ND (0.2) ND (0.2)

CRA 013968 (32) 13968-32-T61.xls

Page 45: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.1

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES

Page 2 of 6

Sample Location: Seep 5013 5041 5042 5043 5044 5045 5045Sample ID: SW-052902-JW-5013 SW-052102-JW-5041 SW-052102-JW-5042 SW-052102-JW-5043 SW-052102-JW-5044 SW-052202-JW-5045 SW-052202-JW-5045ASample Date: 5/29/2002 5/21/2002 5/21/2002 5/21/2002 5/21/2002 5/22/2002 5/22/2002

Duplicate

Parameter Unit

Aroclor-1248 (PCB-1248) ug/L 0.4 ND (1) 4.6 J ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1254 (PCB-1254) ug/L ND (0.2) ND (1) ND (1) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1260 (PCB-1260) ug/L 0.11 J ND (1) ND (1) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) Sum of Detected PCBs (ND=0) ug/L 0.51 J 12 4.6 J 2.1 0.97 0 0

Aroclor-1016 (PCB-1016), dissolved ug/L ND (0.2) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1221 (PCB-1221), dissolved ug/L ND (0.2) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1232 (PCB-1232), dissolved ug/L ND (0.4) UJ ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) Aroclor-1242 (PCB-1242), dissolved ug/L ND (0.2) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1248 (PCB-1248), dissolved ug/L ND (0.2) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1254 (PCB-1254), dissolved ug/L ND (0.2) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) Aroclor-1260 (PCB-1260), dissolved ug/L ND (0.2) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) Sum of Detected PCBs (ND=0) ug/L 0 0 0 0 0 0 0

CRA 013968 (32) 13968-32-T61.xls

Page 46: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.1

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES

Page 3 of 6

Sample Location: Seep 5013 5041 5042 5043 5044 5045 5045Sample ID: SW-052902-JW-5013 SW-052102-JW-5041 SW-052102-JW-5042 SW-052102-JW-5043 SW-052102-JW-5044 SW-052202-JW-5045 SW-052202-JW-5045ASample Date: 5/29/2002 5/21/2002 5/21/2002 5/21/2002 5/21/2002 5/22/2002 5/22/2002

Duplicate

Parameter Unit

Semi - Volatiles

2,2'-oxybis(1-Chloropropane) ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4,5-Trichlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4,6-Trichlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4-Dichlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4-Dimethylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4-Dinitrophenol ug/L ND (50) UJ ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 2,4-Dinitrotoluene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,6-Dinitrotoluene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Chloronaphthalene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Chlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Methylnaphthalene ug/L 0.82 J ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Methylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Nitroaniline ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 2-Nitrophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 3,3'-Dichlorobenzidine ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 3-Nitroaniline ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 4,6-Dinitro-2-methylphenol ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 4-Bromophenyl phenyl ether ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Chloro-3-methylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Chloroaniline ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Chlorophenyl phenyl ether ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Methylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Nitroaniline ug/L ND (50) ND (50) ND (50) UJ ND (50) ND (50) ND (50) ND (50) 4-Nitrophenol ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) Acenaphthene ug/L 0.95 J ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Acenaphthylene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Acetophenone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Anthracene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Atrazine ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzaldehyde ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(a)anthracene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(a)pyrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(b)fluoranthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(g,h,i)perylene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(k)fluoranthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Biphenyl ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) bis(2-Chloroethoxy)methane ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) bis(2-Chloroethyl)ether ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) bis(2-Ethylhexyl)phthalate ug/L 3.5 J ND (10) ND (10) ND (10) ND (10) 8.5 J 8 JButyl benzylphthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Caprolactam ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Carbazole ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Chrysene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Dibenz(a,h)anthracene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Dibenzofuran ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Diethyl phthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Dimethyl phthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Di-n-butylphthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Di-n-octyl phthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Fluoranthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10)

CRA 013968 (32) 13968-32-T61.xls

Page 47: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.1

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES

Page 4 of 6

Sample Location: Seep 5013 5041 5042 5043 5044 5045 5045Sample ID: SW-052902-JW-5013 SW-052102-JW-5041 SW-052102-JW-5042 SW-052102-JW-5043 SW-052102-JW-5044 SW-052202-JW-5045 SW-052202-JW-5045ASample Date: 5/29/2002 5/21/2002 5/21/2002 5/21/2002 5/21/2002 5/22/2002 5/22/2002

Duplicate

Parameter Unit

Fluorene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Hexachlorobenzene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Hexachlorobutadiene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Hexachlorocyclopentadiene ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) Hexachloroethane ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Indeno(1,2,3-cd)pyrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Isophorone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Naphthalene ug/L 4.3 J ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Nitrobenzene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) N-Nitrosodi-n-propylamine ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) N-Nitrosodiphenylamine ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Pentachlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Phenanthrene ug/L 0.99 J ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Phenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Pyrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10)

CRA 013968 (32) 13968-32-T61.xls

Page 48: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.1

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES

Page 5 of 6

Sample Location: Seep 5013 5041 5042 5043 5044 5045 5045Sample ID: SW-052902-JW-5013 SW-052102-JW-5041 SW-052102-JW-5042 SW-052102-JW-5043 SW-052102-JW-5044 SW-052202-JW-5045 SW-052202-JW-5045ASample Date: 5/29/2002 5/21/2002 5/21/2002 5/21/2002 5/21/2002 5/22/2002 5/22/2002

Duplicate

Parameter Unit

Volatiles

1,1,1-Trichloroethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,1,2,2-Tetrachloroethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,1,2-Trichloroethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,1-Dichloroethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,1-Dichloroethene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,2,4-Trichlorobenzene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,2-Dibromo-3-chloropropane (DBCP) ug/L ND (2) ND (2) ND (2) ND (2) ND (2) ND (2) ND (2) 1,2-Dibromoethane (Ethylene Dibromide) ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,2-Dichlorobenzene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,2-Dichloroethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,2-Dichloropropane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) 1,3-Dichlorobenzene ug/L ND (1) 0.81 J ND (1) 0.21 J ND (1) ND (1) ND (1) 1,4-Dichlorobenzene ug/L ND (1) 1.5 0.27 J 0.51 J ND (1) ND (1) ND (1) 2-Butanone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) UJ ND (10) UJ2-Hexanone ug/L ND (10) ND (10) UJ ND (10) UJ ND (10) UJ ND (10) UJ ND (10) ND (10) 4-Methyl-2-pentanone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Acetone ug/L ND (10) U ND (10) UJ ND (10) UJ ND (10) UJ ND (10) UJ ND (10) UJ ND (10) UJBenzene ug/L 0.17 J ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Bromodichloromethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) 0.33 J 0.28 JBromoform ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Bromomethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Carbon disulfide ug/L ND (1) ND (1) 0.37 J 0.35 J ND (1) ND (1) ND (1) Carbon tetrachloride ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Chlorobenzene ug/L ND (1) 0.49 J 0.29 J 0.34 J ND (1) ND (1) ND (1) Chloroethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Chloroform (Trichloromethane) ug/L ND (1) ND (1) ND (1) ND (1) ND (1) 1.4 1.4 Chloromethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) cis-1,2-Dichloroethene ug/L ND (0.5) 1.9 ND (0.5) ND (0.5) ND (0.5) ND (0.5) ND (0.5) cis-1,3-Dichloropropene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Cyclohexane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Dibromochloromethane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Dichlorodifluoromethane (CFC-12) ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Ethylbenzene ug/L 0.33 J ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Isopropylbenzene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Methyl acetate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Methyl cyclohexane ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) UJ ND (1) UJMethyl Tert Butyl Ether ug/L 0.35 J ND (5) ND (5) ND (5) ND (5) ND (5) ND (5) Methylene chloride ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Styrene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Tetrachloroethene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Toluene ug/L 0.91 J ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) trans-1,2-Dichloroethene ug/L ND (0.5) 0.28 J ND (0.5) ND (0.5) ND (0.5) ND (0.5) ND (0.5) trans-1,3-Dichloropropene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Trichloroethene ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Trichlorofluoromethane (CFC-11) ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) Trifluorotrichloroethane (Freon 113) ug/L ND (1) ND (1) ND (1) ND (1) ND (1) ND (1) UJ ND (1) UJVinyl chloride ug/L ND (1) 0.71 J ND (1) ND (1) ND (1) ND (1) ND (1) Xylene (total) ug/L 0.44 J ND (1) ND (1) ND (1) ND (1) ND (1) ND (1)

General Chemistry

CRA 013968 (32) 13968-32-T61.xls

Page 49: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.1

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES

Page 6 of 6

Sample Location: Seep 5013 5041 5042 5043 5044 5045 5045Sample ID: SW-052902-JW-5013 SW-052102-JW-5041 SW-052102-JW-5042 SW-052102-JW-5043 SW-052102-JW-5044 SW-052202-JW-5045 SW-052202-JW-5045ASample Date: 5/29/2002 5/21/2002 5/21/2002 5/21/2002 5/21/2002 5/22/2002 5/22/2002

Duplicate

Parameter Unit

Ammonia mg/L 3.3 0.1 J 0.4 0.4 0.07 J 0.04 J 0.05 JChloride mg/L 52.6 - - - 182 42.8 43.1 pH (water) none 7.4 7.6 8 7.9 7.9 8.1 8.2 Total Dissolved Solids (TDS) mg/L 660 980 890 830 700 340 280 Total Kjeldahl Nitrogen (TKN) mg/L 4 3 2 3 ND (1) ND (1) 0.6 JTotal Suspended Solids (TSS) mg/L 200 ND (4) 960 1900 ND (4) 4 4

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

CRA 013968 (32) 13968-32-T61.xls

Page 50: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 1 of 13

Sample Location: 001(P037) 001(P037) 003(P037) 535/536 537Sample ID: SW-37-022802-JW-001 SW-37-022802-JW-002 SW-37-022802-JW-003 SW-00-012902-JW-535 SW-00-012902-JW-537Sample Date: 2/28/2002 2/28/2002 2/28/2002 1/29/2002 1/29/2002Sample Depth:

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/L ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) Aroclor-1221 (PCB-1221) ug/L ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) Aroclor-1232 (PCB-1232) ug/L ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) Aroclor-1242 (PCB-1242) ug/L ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) Aroclor-1248 (PCB-1248) ug/L ND (0.20) ND (0.20) ND (0.20) 0.69 1.0 Aroclor-1254 (PCB-1254) ug/L ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) Aroclor-1260 (PCB-1260) ug/L ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

Sum of Detected PCBs (ND=0) ug/L 0 0 0 0.69 1

Aroclor-1016 (PCB-1016), dissolved ug/L - - - ND (0.20) UJ ND (0.20) Aroclor-1221 (PCB-1221), dissolved ug/L - - - ND (0.20) UJ ND (0.20) Aroclor-1232 (PCB-1232), dissolved ug/L - - - ND (0.40) UJ ND (0.40) Aroclor-1242 (PCB-1242), dissolved ug/L - - - ND (0.20) UJ ND (0.20) Aroclor-1248 (PCB-1248), dissolved ug/L - - - ND (0.20) UJ ND (0.20) Aroclor-1254 (PCB-1254), dissolved ug/L - - - ND (0.20) UJ ND (0.20) Aroclor-1260 (PCB-1260), dissolved ug/L - - - ND (0.20) UJ ND (0.20)

Sum of Detected PCBs (ND=0) ug/L N/A N/A N/A 0 0

CRA 013968 (32)

Page 51: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 2 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

537 541/542 547 550/551 550/551SW-00-012902-JW-537A SW-00-012902-JH-542 SW-00-012902-JH-547 SW-00-012902-JH-550 SW-00-012902-JH-550A

1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/29/2002

Duplicate Duplicate

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0.99 ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0.99 0 0 0 0

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 52: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 3 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

556/557 560/561 560/561 564/565 730/732SW-00-013002-MD-556 SW-00-013002-MD-560 SW-00-013002-MD-560A SW-00-013002-JH-565 OS-00-020102-JW-732

1/30/2002 1/30/2002 1/30/2002 1/30/2002 2/1/2002

Duplicate

ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (40) ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (40) ND (0.40) UJ ND (0.40) ND (0.40) ND (0.40) ND (80) ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) 500 ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (40) ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (40) ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) 15 J

0 0 0 0 515 J

ND (0.20) ND (0.20) ND (0.20) ND (0.20) -ND (0.20) ND (0.20) ND (0.20) ND (0.20) -ND (0.40) ND (0.40) ND (0.40) ND (0.40) -ND (0.20) ND (0.20) ND (0.20) ND (0.20) -ND (0.20) ND (0.20) ND (0.20) ND (0.20) -ND (0.20) ND (0.20) ND (0.20) ND (0.20) -ND (0.20) ND (0.20) ND (0.20) 0.054 J -

0 0 0 0.054 J N/A

CRA 013968 (32)

Page 53: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 4 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

731/733 731/733 802/803 802/803 806/807OS-00-020102-JW-733 OS-00-020102-JW-733A SW-00-020602-JW-802 SW-00-020602-JW-802A SW-00-020602-JW-806

2/1/2002 2/1/2002 2/6/2002 2/6/2002 2/6/2002

Duplicate Duplicate

ND (100) ND (100) ND (0.20) ND (0.20) ND (0.20) ND (100) ND (100) ND (0.20) ND (0.20) ND (0.20) ND (200) ND (200) ND (0.40) ND (0.40) ND (0.40)

870 1200 ND (0.20) ND (0.20) ND (0.20) ND (100) ND (100) ND (0.20) ND (0.20) ND (0.20) ND (100) ND (100) ND (0.20) ND (0.20) ND (0.20) ND (100) 29 J ND (0.20) ND (0.20) ND (0.20)

870 1,229 J 0 0 0

- - ND (0.20) ND (0.20) ND (0.20) UJ- - ND (0.20) ND (0.20) ND (0.20) UJ- - ND (0.40) ND (0.40) ND (0.40) UJ- - ND (0.20) ND (0.20) ND (0.20) UJ- - ND (0.20) ND (0.20) ND (0.20) UJ- - ND (0.20) ND (0.20) ND (0.20) UJ- - ND (0.20) ND (0.20) ND (0.20) UJ

N/A N/A 0 0 0

CRA 013968 (32)

Page 54: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 5 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

810/811 814/815 1161/1162 1165/1166 1165/1166SW-00-020602-JH-810 SW-00-020602-JW-814 SW-00-030402-JW-1162 SW-00-030402-JW-1166 SW-00-030402-JW-1166A

2/6/2002 2/6/2002 3/4/2002 3/4/2002 3/4/2002

Duplicate

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 55: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 6 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

1169/1170 1173/1174 1177/1178 1182/1183 1193/1194SW-00-030402-JW-1170 SW-00-030402-JW-1174 SW-00-030402-LM-1178 SW-00-030402-LM-1183 SW-00-030502-JK-1194

3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/5/2002

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 56: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 7 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

1193/1194 1197/1198 1212/1213 1252 1252SW-00-030502-JK-1194A SW-00-030502-JK-1198 SW-00-030502-JW-1213 SW-00-030702-LM-1252 SW-00-030702-LM-1252A

3/5/2002 3/5/2002 3/5/2002 3/7/2002 3/7/2002

Duplicate Duplicate

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) 0.17 J ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) UJ ND (0.20) UJND (0.20) ND (0.20) ND (0.20) ND (0.20) UJ ND (0.20) UJ

0 0 0.17 J 0 0

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 57: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 8 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

1255/1256 1444/1445 1448/1449 Spring 15-001 15-001SW-00-LM-1256 SW-00-031802-JW-1445 SW-00-031802-JW-1449 1448/1449 SW-16-020602-JK-001 SW-16-020602-JK-001A

3/7/2002 3/18/2002 3/18/2002 SW-00-031802-JW-1449A 2/6/2002 2/6/20023/18/2002

Duplicate

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0 0

ND (0.20) ND (0.20) ND (0.20) ND (0.20) - -ND (0.20) ND (0.20) ND (0.20) ND (0.20) - -ND (0.40) ND (0.40) ND (0.40) ND (0.40) - -ND (0.20) ND (0.20) ND (0.20) ND (0.20) - -ND (0.20) ND (0.20) ND (0.20) ND (0.20) - -ND (0.20) ND (0.20) ND (0.20) ND (0.20) - -ND (0.20) ND (0.20) ND (0.20) ND (0.20) - -

0 0 0 0 N/A N/A

CRA 013968 (32)

Page 58: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 9 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

1622/1623 1630/1631 5011 5020 5021 5022SW-00-040802-LM-1623 SW-00-040802-GS-1630 SW-051702-SK-5011 SW-051502-JW-5020 SW-051502-JW-5021 SW-051502-JW-5022

4/8/2002 4/8/2002 5/17/2002 5/15/2002 5/15/2002 5/15/2002

ND (0.20) ND (0.20) ND (0.2) UJ ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.20) ND (0.20) ND (0.2) UJ ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.40) ND (0.40) ND (0.4) UJ ND (0.40) UJ ND (0.40) UJ ND (0.40) UJND (0.20) ND (0.20) 0.51 J ND (0.20) UJ ND (0.20) UJ ND (0.20) UJ

0.16 J ND (0.20) ND (0.2) UJ ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.20) ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20) ND (0.20)

0.16 J 0 0.51 J 0 0 0

ND (0.20) ND (0.20) R ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.20) ND (0.20) R ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.40) ND (0.40) R ND (0.40) UJ ND (0.40) UJ ND (0.40) UJND (0.20) ND (0.20) 0.078 J ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.20) ND (0.20) R ND (0.20) UJ ND (0.20) UJ ND (0.20) UJND (0.20) ND (0.20) R ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) R ND (0.20) ND (0.20) ND (0.20)

0 0 0.078 J 0 0 0

CRA 013968 (32)

Page 59: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 10 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

5022 5023 5024 5025 5026 5027SW-051502-JW-5022A SW-051502-JW-5023 SW-051502-JW-5024 SW-051602-JW-5025 SW-051602-JW-5026 SW-051602-JW-5027

5/15/2002 5/15/2002 5/15/2002 5/16/2002 5/16/2002 5/16/2002

Duplicate

ND (0.20) UJ ND (0.20) UJ ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJ ND (0.20) UJ ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2) UJND (0.40) UJ ND (0.40) UJ ND (0.40) UJ ND (0.4) ND (0.4) ND (0.4) ND (0.20) UJ ND (0.20) UJ ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2) UJND (0.20) UJ ND (0.20) UJ ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2)

ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.2) ND (0.2)

0 0 0 0 0 0

ND (0.20) UJ ND (0.20) ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJ ND (0.20) ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.40) UJ ND (0.40) ND (0.40) UJ ND (0.4) ND (0.4) ND (0.4) ND (0.20) UJ 2.0 ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJ ND (0.20) ND (0.20) UJ ND (0.2) ND (0.2) ND (0.2)

ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) 3.0 ND (0.20) ND (0.2) ND (0.2) ND (0.2)

0 5 0 0 0 0

CRA 013968 (32)

Page 60: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 11 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

5028 5029 5030 5031 5033 5035SW-051602-JW-5028 SW-051702-JW-5029 SW-051702-JW-5030 SW-051702-JW-5031 SW-052002-GS-5033 SW-052002-GS-5035

5/16/2002 5/17/2002 5/17/2002 5/17/2002 5/20/2002 5/20/2002

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJ ND (0.2) UJ ND (0.2) UJ ND (0.2) UJ ND (0.2) ND (0.2)

ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.2) UJ 1.9 J 1.1 J ND (0.2) UJ ND (0.2) ND (0.2)

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2)

0 1.9 J 1.1 J 0 0 0

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2)

0 0 0 0 0 0

CRA 013968 (32)

Page 61: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 12 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

5036 5037 5038 5039 5040 5046SW-052002-GS-5036 SW-052002-GS-5037 SW-052002-GS-5038 SW-052002-GS-5039 SW-052002-GS-5040 SW-052202-JW-5046

5/20/2002 5/20/2002 5/20/2002 5/20/2002 5/20/2002 5/22/2002

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) UJ

0 0 0 0 0 0

ND (0.2) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) 4.1 ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.8) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.2) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2)

0 4.1 0 0 0 0

CRA 013968 (32)

Page 62: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.2

ANALYTICAL RESULTS SUMMARYSURFACE WATER SAMPLES - PCB ANALYSIS

Page 13 of 13

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

5047 5056 PARCEL 400 MANHOLE Pleasant RunSW-052202-JW-5047 SW-052802-GS-5056 SW-060602-JW-001 SW-00-020702-JK-002

5/22/2002 5/28/2002 6/6/2002 2/7/2002

ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.4) ND (0.40) ND (0.40) ND (0.40)

1.2 ND (0.20) 0.58 ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20)

1.2 0 0.58 0

ND (0.2) ND (0.20) ND (0.20) -ND (0.2) ND (0.20) ND (0.20) -ND (0.4) ND (0.40) ND (0.40) -ND (0.2) ND (0.20) ND (0.20) -ND (0.2) ND (0.20) ND (0.20) -ND (0.2) ND (0.20) ND (0.20) -ND (0.2) ND (0.20) ND (0.20) -

0 0 0 N/A

CRA 013968 (32)

Page 63: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 1 of 14

Sample Location: 535/536 538 538 541/542 550/551 556/557Sample ID: SD-00-012902-JW-536 SD-00-012902-JW-538 SD-00-012902-JW-538A SD-00-012902-JH-541 SD-00-012902-JH-551 SD-00-013002-LM-557Sample Date: 1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/30/2002Sample Depth: (0-0.01) (0-0.25) (0-0.25)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (1400) ND (85) ND (49) ND (73) ND (750) ND (49) Aroclor-1221 (PCB-1221) ug/Kg ND (1400) ND (85) ND (49) ND (73) ND (750) ND (49) Aroclor-1232 (PCB-1232) ug/Kg ND (1400) ND (85) ND (49) ND (73) ND (750) ND (49) Aroclor-1242 (PCB-1242) ug/Kg ND (1400) ND (85) ND (49) ND (73) ND (750) ND (49) Aroclor-1248 (PCB-1248) ug/Kg 10000 400 130 ND (73) ND (750) ND (49) Aroclor-1254 (PCB-1254) ug/Kg ND (1400) ND (85) ND (49) ND (73) ND (750) U ND (49) Aroclor-1260 (PCB-1260) ug/Kg 2000 57 J ND (49) ND (73) ND (750) ND (49)

Sum of Detected PCBs (ND=0) ug/Kg 12,000 457 J 130 0 0 0

CRA 013968 (32)

Page 64: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 2 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

560/561 564/565 730/732 731/733 802/803 806/807SD-00-013002-LM-561 SD-00-013002-TR-564 SD-00-020102-JW-730 SD-00-020102-JH-731 SD-00-020602-JH-803 SD-00-020602-JH-807

1/30/2002 1/30/2002 2/1/2002 2/1/2002 2/6/2002 2/6/2002

ND (50) ND (47) ND (11000) ND (4400000) ND (50) ND (74) ND (50) ND (47) ND (11000) ND (4400000) ND (50) ND (74) ND (50) ND (47) ND (11000) ND (4400000) ND (50) ND (74) ND (50) ND (47) 150000 25000000 ND (50) ND (74) ND (50) 17 J ND (11000) ND (4400000) ND (50) ND (74) ND (50) ND (47) ND (11000) ND (4400000) ND (50) ND (74) ND (50) ND (47) 7800 J ND (4400000) ND (50) ND (74)

0 17 J 157,800 J 25,000,000 0 0

CRA 013968 (32)

Page 65: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 3 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

810/811 814/815 952 1006 1007 1008SD-00-020602-JH-811 SD-00-020602-JH-815 SD-00-021902-GS-952 SD-00-022002-CH-1006 SD-00-022002-CH-1007 SD-00-022002-CH-1008

2/6/2002 2/6/2002 2/19/2002 2/20/2002 2/20/2002 2/20/2002

ND (43) ND (47) ND (64) ND (70) ND (62) ND (66) ND (43) ND (47) ND (64) ND (70) ND (62) ND (66) ND (43) ND (47) ND (64) ND (70) ND (62) ND (66) ND (43) ND (47) ND (64) ND (70) ND (62) ND (66) ND (43) ND (47) ND (64) 370 230 350 ND (43) ND (47) ND (64) ND (70) ND (62) ND (66) ND (43) ND (47) ND (64) 46 J 28 J 37 J

0 0 0 416 J 258 J 387 J

CRA 013968 (32)

Page 66: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 4 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1020 1120 1146 1146 1147SD-00-022002-CH-1020 SD-00-022502-JW-1120 SD-00-022702-CH-1146 SD-00-022702-CH-1146A SD-00-022702-CH-1147

2/20/2002 2/25/2002 2/27/2002 2/27/2002 2/27/2002

Duplicate

ND (76) ND (550) ND (280) ND (320) ND (57) ND (76) ND (550) ND (280) ND (320) ND (57) ND (76) ND (550) ND (280) ND (320) ND (57) ND (76) ND (550) ND (280) ND (320) ND (57)

200 4200 1800 2600 580 ND (76) ND (550) ND (280) ND (320) ND (57)

29 J 660 280 480 140

229 J 4,860 2,080 3,080 720

CRA 013968 (32)

Page 67: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 5 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1148 1149 1150 1151 1152 1153SD-00-022702-CH-1148 SD-00-022702-CH-1149 SD-00-022702-JW-1150 SD-00-022702-JW-1151 SD-00-022702-JW-1152 SD-00-022702-JW-1153

2/27/2002 2/27/2002 2/27/2002 2/27/2002 2/27/2002 2/27/2002

ND (57) ND (560) ND (59) ND (94) ND (80) ND (81) ND (57) ND (560) ND (59) ND (94) ND (80) ND (81) ND (57) ND (560) ND (59) ND (94) ND (80) ND (81) ND (57) ND (560) ND (59) ND (94) ND (80) ND (81)

790 11000 ND (59) 390 170 ND (81) ND (57) ND (560) 200 ND (94) ND (80) 100

180 1100 ND (59) 72 J 54 J ND (81)

970 12,100 200 462 J 224 J 100

CRA 013968 (32)

Page 68: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 6 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1161/1162 1161/1162 1165/1166 1169/1170 1173/1174 1177/1178SD-00-030402-JH-1161 SD-00-030402-JH-1161A SD-00-030402-JH-1165 SD-00-030402-JH-1169 SD-00-030402-JH-1173 SD-00-030402-JH-1177

3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002

Duplicate

ND (40) ND (45) ND (43) ND (47) ND (92) ND (45) ND (40) ND (45) ND (43) ND (47) ND (92) ND (45) ND (40) ND (45) ND (43) ND (47) ND (92) ND (45) ND (40) ND (45) ND (43) ND (47) ND (92) ND (45)

310 370 300 270 1200 330 ND (40) ND (45) ND (43) ND (47) ND (92) ND (45) ND (40) 86 38 J 52 70 J 60

310 456 338 J 322 1,270 J 390

CRA 013968 (32)

Page 69: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 7 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1182/1183 1193/1194 1193/1194 1197/1198 1212/1213 1216SD-00-030402-JH-1182 SD-00-030502-JH-1193 SD-00-030502-JH-1193A SD-00-030502-JH-1197 SD-00-030502-LM-1212 SD-00-030602-JH-1216

3/4/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/6/2002

Duplicate

ND (51) ND (54) ND (100) ND (56) ND (50) ND (46) ND (51) ND (54) ND (100) ND (56) ND (50) ND (46) ND (51) ND (54) ND (100) ND (56) ND (50) ND (46) ND (51) ND (54) ND (100) ND (56) ND (50) ND (46)

770 J 440 690 260 220 ND (46) ND (51) ND (54) ND (100) ND (56) ND (50) ND (46)

96 J 50 J 67 J 30 J 29 J ND (46) UJ

866 J 490 J 757 J 290 J 249 J 0

CRA 013968 (32)

Page 70: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 8 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1216 1217 1218 1223 1228 1250SD-00-030602-JH-1216A SD-00-030602-JH-1217 SD-00-030602-JH-1218 SD-00-030602-JH-1223 SD-00-030602-JH-1228 SD-00-030702-LM-1250

3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/7/2002

Duplicate

ND (44) ND (56) ND (47) ND (45) ND (55) ND (62) ND (44) ND (56) ND (47) ND (45) ND (55) ND (62) ND (44) ND (56) ND (47) ND (45) ND (55) ND (62) ND (44) ND (56) ND (47) ND (45) ND (55) ND (62) ND (44) ND (56) ND (47) ND (45) ND (55) 370 ND (44) ND (56) ND (47) ND (45) ND (55) ND (62)

ND (44) UJ ND (56) ND (47) ND (45) ND (55) 40 J

0 0 0 0 0 410 J

CRA 013968 (32)

Page 71: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 9 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1250 1251 1255/1256 1430 1430SD-00-030702-LM-1250A SD-00-030702-LM-1251 SD-00-030702-LM-1255 SD-00-031502-RB-1430 SD-00-031502-RB-1430B

3/7/2002 3/7/2002 3/7/2002 3/15/2002 3/15/2002(0-0.83) (0-0.83)

Duplicate Duplicate

ND (63) ND (61) ND (52) ND (1400) ND (1400) ND (63) ND (61) ND (52) 7500 4500 ND (63) ND (61) ND (52) ND (1400) ND (1400) ND (63) ND (61) ND (52) ND (1400) ND (1400)

260 240 47 J 1300 J 700 JND (63) ND (61) ND (52) ND (1400) ND (1400)

30 J 25 J ND (52) ND (1400) ND (1400)

290 J 265 J 47 J 8,800 J 5,200 J

CRA 013968 (32)

Page 72: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 10 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1430 1431 1431 1432 1432 1433SD-00-031502-RB-1430A SD-00-031502-RB-1431 SD-00-RB-1431A SD-00-031502-RB-1432 SD-00-031502-RB-1432A SD-00-031502-RB-1433

3/15/2002 3/15/2002 3/15/2002 3/15/2002 3/15/2002 3/15/2002(0.83-1.67) (0-0.83) (0.83-1.67) (0-0.83) (0.83-1.5) (0-0.83)

ND (64) ND (960) ND (850) ND (110) ND (58) ND (89) 230 5100 6600 ND (110) ND (58) ND (89)

ND (64) ND (960) ND (850) ND (110) ND (58) ND (89) ND (64) ND (960) ND (850) ND (110) ND (58) ND (89)

34 J 890 J 840 J 26 J ND (58) 29 JND (64) ND (960) ND (850) ND (110) ND (58) ND (89) ND (64) ND (960) ND (850) ND (110) ND (58) ND (89)

264 J 5,990 J 7,440 J 26 J 0 29 J

CRA 013968 (32)

Page 73: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 11 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1433 1444/1445 1448/1449 1448/1449 1622/1623SD-00-031502-RB-1433A SD-00-031802-JW-1444 SD-00-031802-JW-1448 SD-00-031802-JW-1448A SD-00-040802-GS-1622

3/15/2002 3/18/2002 3/18/2002 3/18/2002 4/8/2002(0.83-1.33)

Duplicate

ND (61) ND (52) ND (47) ND (45) ND (600) ND (61) ND (52) ND (47) ND (45) ND (600) ND (61) ND (52) ND (47) ND (45) ND (600) ND (61) ND (52) ND (47) ND (45) ND (600) ND (61) ND (52) 10 J 7.6 J 3100 ND (61) ND (52) ND (47) ND (45) ND (600) ND (61) ND (52) ND (47) ND (45) 580 J

0 0 10 J 7.6 J 3,680 J

CRA 013968 (32)

Page 74: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 12 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1630/1631 1676 1677 1678 1679 1680SD-00-040802-GS-1631 SD-31-041102-JW-1676 SD-31-041102-JW-1677 SD-31-041102-JW-1678 SD-31-041102-JW-1679 SD-31-041102-JW-1680

4/8/2002 4/11/2002 4/11/2002 4/11/2002 4/11/2002 4/11/2002

ND (100) ND (48) ND (42) ND (39) ND (37) ND (42) ND (100) ND (48) ND (42) ND (39) ND (37) ND (42) ND (100) ND (48) ND (42) ND (39) ND (37) ND (42) ND (100) ND (48) ND (42) ND (39) ND (37) ND (42)

670 ND (48) ND (42) ND (39) ND (37) ND (42) ND (100) ND (48) ND (42) ND (39) ND (37) ND (42)

89 J ND (48) ND (42) ND (39) ND (37) ND (42)

759 J 0 0 0 0 0

CRA 013968 (32)

Page 75: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 13 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1680 1681 1682 1683 1684 1685SD-31-041102-JW-1680A SD-31-041102-JW-1681 SD-31-041102-JW-1682 SD-31-041102-JW-1683 SD-31-041102-JW-1684 SD-31-041102-JW-1685

4/11/2002 4/11/2002 4/11/2002 4/11/2002 4/11/2002 4/11/2002

Duplicate

ND (43) ND (44) ND (44) ND (55) ND (35) ND (63) ND (43) ND (44) ND (44) ND (55) ND (35) ND (63) ND (43) ND (44) ND (44) ND (55) ND (35) ND (63) ND (43) ND (44) ND (44) ND (55) ND (35) ND (63) ND (43) ND (44) ND (44) ND (55) ND (35) ND (63) ND (43) ND (44) ND (44) ND (55) ND (35) ND (63) ND (43) ND (44) ND (44) ND (55) ND (35) ND (63)

0 0 0 0 0 0

CRA 013968 (32)

Page 76: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.3

ANALYTICAL RESULTS SUMMARY SEDIMENT SAMPLES - PCB ANALYSIS

Page 14 of 14

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

1686 1686 1687 1688 1689 SPRING_1452/1453SD-31-041102-JW-1686 SD-31-041102-JW-1686A SD-31-041102-JW-1687 SD-31-041102-JW-1688 SD-31-041102-JW-1689 SD-00-031902-JW-1452

4/11/2002 4/11/2002 4/11/2002 4/11/2002 4/11/2002 3/19/2002

Duplicate

ND (36) ND (37) ND (36) ND (68) ND (51) ND (56) ND (36) ND (37) ND (36) ND (68) ND (51) ND (56) ND (36) ND (37) ND (36) ND (68) ND (51) ND (56) ND (36) ND (37) ND (36) ND (68) ND (51) ND (56) ND (36) ND (37) ND (36) ND (68) ND (51) ND (56) ND (36) ND (37) ND (36) ND (68) ND (51) ND (56) ND (36) ND (37) ND (36) ND (68) ND (51) ND (56)

0 0 0 0 0 0

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

CRA 013968 (32)

Page 77: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.4

ANALYTICAL RESULTS SUMMARYGROUNDWATER RESULTS - PCB ANALYSIS

Sample Location: 15-001 Pleasant RunSample ID: GW-21202-314012-JK-001 GW-00-020702-JK-001Sample Date: 2/12/2002 2/7/2002Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/L ND (0.08) UJ ND (0.2) Aroclor-1221 (PCB-1221) ug/L ND (0.10) UJ ND (0.2) Aroclor-1232 (PCB-1232) ug/L ND (0.10) UJ ND (0.4) Aroclor-1242 (PCB-1242) ug/L ND (0.10) UJ ND (0.2) Aroclor-1248 (PCB-1248) ug/L ND (0.10) UJ ND (0.2) Aroclor-1254 (PCB-1254) ug/L ND (0.10) UJ ND (0.2) Aroclor-1260 (PCB-1260) ug/L ND (0.10) UJ ND (0.2)

Sum of Detected PCBs (ND=0) ug/L 0 0

Aroclor-1016 (PCB-1016), dissolved ug/L - -Aroclor-1221 (PCB-1221), dissolved ug/L - -Aroclor-1232 (PCB-1232), dissolved ug/L - -Aroclor-1242 (PCB-1242), dissolved ug/L - -Aroclor-1248 (PCB-1248), dissolved ug/L - -Aroclor-1254 (PCB-1254), dissolved ug/L - -Aroclor-1260 (PCB-1260), dissolved ug/L - -

Sum of Detected PCBs (ND=0) ug/L N/A N/A

NOTES:J = The reported laboratory result is qualified as an estimated valueUJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

CRA 013968 (32)

Page 78: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 1 of 10

Sample Type: Spring Spring Spring Spring SpringSample Location: Spring_004 (5046) Spring_009 (5048) Spring_018 (5047) SPRING_028-001 SPRING_028-002Sample ID: SW-052202-JW-5046 SW-052202-JW-5048 SW-052202-JW-5047 SW-28-040302-JW-001 SW-28-040302-JW-002Sample Date: 5/22/2002 5/22/2002 5/22/2002 4/3/2002 4/3/2002Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/L ND (0.2) UJ ND (0.2) UJ ND (0.2) ND (0.20) ND (0.20) Aroclor-1221 (PCB-1221) ug/L ND (0.2) UJ ND (0.2) UJ ND (0.2) ND (0.20) ND (0.20) Aroclor-1232 (PCB-1232) ug/L ND (0.4) UJ ND (0.4) UJ ND (0.4) ND (0.40) ND (0.40) Aroclor-1242 (PCB-1242) ug/L ND (0.2) UJ ND (0.2) UJ 1.2 ND (0.20) ND (0.20) Aroclor-1248 (PCB-1248) ug/L ND (0.2) UJ ND (0.2) UJ ND (0.2) ND (0.20) ND (0.20) Aroclor-1254 (PCB-1254) ug/L ND (0.2) UJ ND (0.2) UJ ND (0.2) ND (0.20) ND (0.20) Aroclor-1260 (PCB-1260) ug/L ND (0.2) UJ ND (0.2) UJ ND (0.2) ND (0.20) ND (0.20)

Sum of Detected PCBs (ND=0) ug/L 0 0 1.2 0 0

Aroclor-1016 (PCB-1016), dissolved ug/L ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20) Aroclor-1221 (PCB-1221), dissolved ug/L ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20) Aroclor-1232 (PCB-1232), dissolved ug/L ND (0.4) ND (0.4) ND (0.4) ND (0.40) ND (0.40) Aroclor-1242 (PCB-1242), dissolved ug/L ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20) Aroclor-1248 (PCB-1248), dissolved ug/L ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20) Aroclor-1254 (PCB-1254), dissolved ug/L ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20) Aroclor-1260 (PCB-1260), dissolved ug/L ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.20)

Sum of Detected PCBs (ND=0) ug/L 0 0 0 0 0

CRA 013968 (32)

Page 79: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 2 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring SpringSPRING_40-001 (5053) SPRING_40-001 (5053) SPRING_40-001 (5053) SPRING_40-002 (5054) SPRING_40-002 (5054)

SW-052302-JW-5053 GW-40-022702-LM-001 GW-40-022702-LM-001A GW-40-022702-LM-002 SW-052302-JW-50545/23/2002 2/27/2002 2/27/2002 2/27/2002 5/23/2002

Duplicate

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2)

0 0 0 0 0

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.2)

0 0 0 0 0

CRA 013968 (32)

Page 80: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 3 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring SpringSPRING_40-003 (5052) SPRING_40-003 (5052) SPRING_734 (5051) SPRING_734 (5051) Spring_910 (5014/5015)GW-40-022702-LM-003 SW-052302-JW-5052 GW-00-020102-JW-734 SW-052302-JW-5051 SW-052902-GS-5014

2/27/2002 5/23/2002 2/1/2002 5/23/2002 5/29/2002

ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJND (0.4) ND (0.4) ND (0.4) ND (0.4) ND (0.40) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.2) ND (0.20)

0 0 0 0 0

ND (0.2) ND (0.2) - ND (0.2) ND (0.20) UJND (0.2) ND (0.2) - ND (0.2) ND (0.20) UJND (0.4) ND (0.4) - ND (0.4) ND (0.40) UJND (0.2) ND (0.2) - ND (0.2) ND (0.20) UJND (0.2) ND (0.2) - ND (0.2) ND (0.20) UJND (0.2) ND (0.2) - ND (0.2) ND (0.20) ND (0.2) ND (0.2) - ND (0.2) ND (0.20)

0 0 N/A 0 0

CRA 013968 (32)

Page 81: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 4 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring SpringSpring_910 (5014/5015) SPRING_1452/1453 (5034) SPRING_1452/1453 (5034) SPRING_1459 (5032) SPRING_1459 (5032)

SW-052902-GS-5015 SW-00-031902-JW-1453 SW-052002-JW-5034 SW-00-032102-LM-1459 SW-00-032102-LM-1459A5/29/2002 3/19/2002 5/20/2002 3/21/2002 3/21/2002

Duplicate Duplicate

ND (0.20) UJ ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20) ND (0.20) UJ ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20) ND (0.40) UJ ND (0.40) ND (0.4) UJ ND (0.40) ND (0.40) ND (0.20) UJ ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20) ND (0.20) UJ ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20)

ND (0.20) ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) UJ ND (0.20) ND (0.20)

0 0 0 0 0

ND (0.20) UJ ND (0.20) ND (0.2) ND (0.20) UJ ND (0.20) ND (0.20) UJ ND (0.20) ND (0.2) ND (0.20) UJ ND (0.20) ND (0.40) UJ ND (0.40) ND (0.4) ND (0.40) UJ ND (0.40) ND (0.20) UJ ND (0.20) ND (0.2) ND (0.20) UJ ND (0.20) ND (0.20) UJ ND (0.20) ND (0.2) ND (0.20) UJ ND (0.20)

ND (0.20) ND (0.20) ND (0.2) ND (0.20) UJ ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) UJ ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 82: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 5 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring Spring SpringSPRING_1459 (5032) SPRING_1459 (5032) SPRING_1468 (5049) SPRING_1468 (5049) SPRING_1469 (5050) SPRING_1469 (5050)SW-051702-JW-5032 SW-051702-JW-5032A SW-27-032102-JW-1468 SW-052302-JW-5049 SW-27-032102-JW-1469 SW-052302-JW-5050

5/17/2002 5/17/2002 3/21/2002 5/23/2002 3/21/2002 5/23/2002

Duplicate

ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.2) UJ ND (0.2) UJ ND (0.20) ND (0.2) ND (0.20) ND (0.2)

ND (0.4) ND (0.4) ND (0.40) ND (0.4) ND (0.40) ND (0.4) ND (0.2) UJ ND (0.2) UJ ND (0.20) ND (0.2) ND (0.20) ND (0.2)

ND (0.2) ND (0.2) ND (0.20) ND (0.2) 1.0 ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJ ND (0.2) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) UJ ND (0.2) ND (0.20) ND (0.2)

0 0 0 0 1 0

ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.4) ND (0.4) ND (0.40) ND (0.4) ND (0.40) ND (0.4) ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.2) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.2)

0 0 0 0 0 0

CRA 013968 (32)

Page 83: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 6 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring SpringSPRING_1469 (5050) 1547 (5057) 1547 (5057) 1549 SPRING_1556 (5058)SW-052302-JW-5050A SW-36-032702-JW-1547 SW-052802-GS-5057 SW-36-032702-JW-1549 SW-36-032702-JW-1556

5/23/2002 3/27/2002 5/28/2002 3/27/2002 3/27/2002

Duplicate

ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.4) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.4) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.2) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 84: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 7 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring SpringSPRING_1556A SPRING_1556 (5058) SPRING_1572 1590 (5059) 1590 (5059)

SW-36-032702-JW-1556A SW-052802-GS-5058 SW-31-040202-JW-1572 SW-03-040302-JW-1590 SW-052802-GS-50593/27/2002 5/28/2002 4/2/2002 4/3/2002 5/28/2002

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.40) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20) ND (0.20)

0 0 0 0 0

CRA 013968 (32)

Page 85: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 8 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Spring Spring Spring Spring Seep5055 Spring East of Storm Pond Spring East of Storm Pond-2 SPRING WELL1 Seep_001 (5012)

SW-052802-GS-5055 GW-00-031202-JW-004 GW-00-031202-JW-003 GW-22-010902-LM-001 SW-051702-SK-50125/28/2002 3/12/2002 3/12/2002 1/9/2002 5/17/2002

ND (0.20) ND (0.2) ND (0.2) ND (0.2) RND (0.20) ND (0.2) ND (0.2) ND (0.2) RND (0.40) ND (0.4) ND (0.4) ND (0.4) RND (0.20) ND (0.2) ND (0.2) ND (0.2) RND (0.20) ND (0.2) ND (0.2) ND (0.2) RND (0.20) ND (0.2) ND (0.2) ND (0.2) RND (0.20) ND (0.2) ND (0.2) ND (0.2) R

0 0 0 0 N/A

ND (0.20) ND (0.2) ND (0.2) - ND (0.2) UJND (0.20) ND (0.2) ND (0.2) - ND (0.2) UJND (0.40) ND (0.4) ND (0.4) - ND (0.4) UJND (0.20) ND (0.2) ND (0.2) - ND (0.2) UJND (0.20) ND (0.2) ND (0.2) - ND (0.2) UJND (0.20) ND (0.2) ND (0.2) - ND (0.2) UJND (0.20) ND (0.2) ND (0.2) - ND (0.2) UJ

0 0 0 N/A 0

CRA 013968 (32)

Page 86: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 9 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Seep Seep Seep Seep SeepEastern Seep Area 01 Eastern Seep Area 02 Eastern Seep Area 02 5013 SW-X216Y274

GW-00-031102-GS-001 GW-00-031102-GS-002 GW-00-031102-GS-002A SW-052902-JW-5013 SW-031502-JW-14283/11/2002 3/11/2002 3/11/2002 5/29/2002 3/15/2002

Duplicate

ND (2) ND (20) ND (10) ND (0.2) ND (0.20) UJND (2) ND (20) ND (10) ND (0.2) ND (0.20) UJND (4) ND (40) ND (20) ND (0.4) ND (0.40) UJ

22 180 100 ND (0.2) ND (0.20) UJND (2) ND (20) ND (10) 0.4 2.4 JND (2) ND (20) ND (10) ND (0.2) ND (0.20) UJND (2) ND (20) ND (10) 0.11 J ND (0.20) UJ

22 180 100 0.51 J 2.4 J

ND (0.2) UJ ND (1) ND (4) ND (0.2) UJ ND (0.20) ND (0.2) UJ 10 J 51 ND (0.2) UJ ND (0.20) ND (0.4) UJ ND (2) ND (8) ND (0.4) UJ ND (0.40) ND (0.2) UJ ND (1) ND (4) ND (0.2) UJ ND (0.20) ND (0.2) UJ ND (1) ND (4) ND (0.2) UJ ND (0.20) ND (0.2) UJ ND (1) ND (4) ND (0.2) UJ ND (0.20) ND (0.2) UJ ND (1) ND (4) ND (0.2) UJ ND (0.20)

0 10 J 51 0 0

CRA 013968 (32)

Page 87: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.5

ANALYTICAL RESULTS SUMMARYSPRING/SEEP SAMPLES - PCB ANALYSIS

Page 10 of 10

Sample Type:Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/LAroclor-1221 (PCB-1221) ug/LAroclor-1232 (PCB-1232) ug/LAroclor-1242 (PCB-1242) ug/LAroclor-1248 (PCB-1248) ug/LAroclor-1254 (PCB-1254) ug/LAroclor-1260 (PCB-1260) ug/L

Sum of Detected PCBs (ND=0) ug/L

Aroclor-1016 (PCB-1016), dissolved ug/LAroclor-1221 (PCB-1221), dissolved ug/LAroclor-1232 (PCB-1232), dissolved ug/LAroclor-1242 (PCB-1242), dissolved ug/LAroclor-1248 (PCB-1248), dissolved ug/LAroclor-1254 (PCB-1254), dissolved ug/LAroclor-1260 (PCB-1260), dissolved ug/L

Sum of Detected PCBs (ND=0) ug/L

Seep Seep Seep Seep SeepSW-X216Y274 SW-X243Y232 SW-X243Y232 SW-X256Y260 SW-X256Y260

SW-052102-JW-5042 SW-031502-JW-1426 SW-052102-JW-5041 SW-031502-JW-1427 SW-031502-JW-1427A5/21/2002 3/15/2002 5/21/2002 3/15/2002 3/15/2002

Duplicate

ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40) ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40) ND (1) UJ ND (4.0) ND (2) ND (0.80) ND (0.80) ND (1) UJ 22 12 3.8 4.6

4.6 J ND (2.0) ND (1) ND (0.40) ND (0.40) ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40) ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40)

4.6 J 22 12 3.8 4.6

ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) ND (0.4) ND (2.0) ND (0.4) ND (0.40) ND (0.40) ND (0.2) 13 ND (0.2) ND (0.20) ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20)

0 13 0 0 0

CRA 013968 (32)

Page 88: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.6

ANALYTICAL RESULTS SUMMARYON-SITE SEEP SAMPLES - COMPLETE ANALYTICAL RESULTS

Page 1 of 4

Sample Type: Seep Seep Seep Seep Seep SeepSample Location: SW-X216Y274 SW-X216Y274 SW-X243Y232 SW-X243Y232 SW-X256Y260 SW-X256Y260Sample ID: SW-031502-JW-1428 SW-052102-JW-5042 SW-031502-JW-1426 SW-052102-JW-5041 SW-031502-JW-1427 SW-031502-JW-1427ASample Date: 3/15/2002 5/21/2002 3/15/2002 5/21/2002 3/15/2002 3/15/2002

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/L ND (0.20) UJ ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40) Aroclor-1221 (PCB-1221) ug/L ND (0.20) UJ ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40) Aroclor-1232 (PCB-1232) ug/L ND (0.40) UJ ND (1) UJ ND (4.0) ND (2) ND (0.80) ND (0.80) Aroclor-1242 (PCB-1242) ug/L ND (0.20) UJ ND (1) UJ 22 12 3.8 4.6 Aroclor-1248 (PCB-1248) ug/L 2.4 J 4.6 J ND (2.0) ND (1) ND (0.40) ND (0.40) Aroclor-1254 (PCB-1254) ug/L ND (0.20) UJ ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40) Aroclor-1260 (PCB-1260) ug/L ND (0.20) UJ ND (1) UJ ND (2.0) ND (1) ND (0.40) ND (0.40)

Sum of Detected PCBs (ND=0) ug/L 2.4 J 4.6 J 22 12 3.8 4.6

PCBs (Dissolved)

Aroclor-1016 (PCB-1016), dissolved ug/L ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) Aroclor-1221 (PCB-1221), dissolved ug/L ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) Aroclor-1232 (PCB-1232), dissolved ug/L ND (0.40) ND (0.4) ND (2.0) ND (0.4) ND (0.40) ND (0.40) Aroclor-1242 (PCB-1242), dissolved ug/L ND (0.20) ND (0.2) 13 ND (0.2) ND (0.20) ND (0.20) Aroclor-1248 (PCB-1248), dissolved ug/L ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) Aroclor-1254 (PCB-1254), dissolved ug/L ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20) Aroclor-1260 (PCB-1260), dissolved ug/L ND (0.20) ND (0.2) ND (1.0) ND (0.2) ND (0.20) ND (0.20)

Sum of Detected PCBs (ND=0) ug/L 0 0 13 0 0 0

Metals

Aluminum mg/L 9.7 56.2 ND (0.20) ND (0.2) ND (0.20) ND (0.20) Antimony mg/L ND (0.060) 0.0043 J ND (0.060) ND (0.06) ND (0.060) ND (0.060) Arsenic mg/L 0.015 0.081 ND (0.010) ND (0.01) ND (0.010) ND (0.010) Barium mg/L 0.32 0.89 0.065 J 0.06 J 0.066 J 0.066 JBeryllium mg/L ND (0.0050) 0.0014 J ND (0.0050) ND (0.005) ND (0.0050) ND (0.0050) Cadmium mg/L ND (0.0050) ND (0.005) ND (0.0050) ND (0.005) ND (0.0050) ND (0.0050) Chromium mg/L 0.014 0.087 ND (0.010) ND (0.01) ND (0.010) ND (0.010) Cobalt mg/L 0.022 J 0.12 ND (0.050) U 0.0024 J ND (0.050) ND (0.050) Copper mg/L 0.077 0.38 ND (0.025) ND (0.025) ND (0.025) ND (0.025) Cyanide (amenable) mg/L ND (0.010) ND (0.01) ND (0.010) ND (0.01) ND (0.010) ND (0.010) Cyanide (total) mg/L ND (0.010) ND (0.01) ND (0.010) ND (0.01) ND (0.010) ND (0.010) Iron mg/L 72.5 306 1.4 1.4 0.31 0.31 Lead mg/L 0.0094 0.067 ND (0.0030) ND (0.003) ND (0.0030) ND (0.0030) Manganese mg/L 12.7 57.4 1.4 1.2 0.54 0.53 Mercury mg/L 0.0010 0.00058 ND (0.00020) UJ ND (0.0002) ND (0.00020) UJ ND (0.00020) UJNickel mg/L 0.025 J 0.15 0.0024 J 0.0038 J ND (0.040) ND (0.040) Selenium mg/L ND (0.0050) ND (0.025) ND (0.0050) ND (0.005) ND (0.0050) ND (0.0050) Silver mg/L ND (0.010) 0.0031 J ND (0.010) ND (0.01) ND (0.010) ND (0.010) Thallium mg/L 0.0098 J ND (0.001) 0.0070 J ND (0.001) 0.0081 J 0.0075 JVanadium mg/L 0.016 J 0.096 ND (0.050) ND (0.05) ND (0.050) ND (0.050) Zinc mg/L 0.071 0.42 ND (0.020) ND (0.02) ND (0.020) ND (0.020)

Metals (Dissolved)

Aluminum (Dissolved) mg/L ND (0.20) ND (0.2) ND (0.20) ND (0.2) ND (0.20) ND (0.20) Antimony (Dissolved) mg/L ND (0.060) ND (0.06) 0.0027 J ND (0.06) ND (0.060) ND (0.060) Arsenic (Dissolved) mg/L ND (0.010) ND (0.01) ND (0.010) ND (0.01) ND (0.010) ND (0.010)

CRA 013968 (32)

Page 89: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.6

ANALYTICAL RESULTS SUMMARYON-SITE SEEP SAMPLES - COMPLETE ANALYTICAL RESULTS

Page 2 of 4

Sample Location: SW-X216Y274 SW-X216Y274 SW-X243Y232 SW-X243Y232 SW-X256Y260 SW-X256Y260Sample ID: SW-031502-JW-1428 SW-052102-JW-5042 SW-031502-JW-1426 SW-052102-JW-5041 SW-031502-JW-1427 SW-031502-JW-1427ASample Date: 3/15/2002 5/21/2002 3/15/2002 5/21/2002 3/15/2002 3/15/2002

Duplicate

Parameter Unit

Barium (Dissolved) mg/L 0.085 J 0.093 J 0.065 J 0.059 J 0.064 J 0.064 JBeryllium (Dissolved) mg/L ND (0.0050) ND (0.005) ND (0.0050) ND (0.005) ND (0.0050) ND (0.0050) Cadmium (Dissolved) mg/L ND (0.0050) ND (0.005) ND (0.0050) ND (0.005) ND (0.0050) ND (0.0050) Chromium (Dissolved) mg/L ND (0.010) ND (0.01) ND (0.010) ND (0.01) ND (0.010) ND (0.010) Cobalt (Dissolved) mg/L ND (0.050) ND (0.05) ND (0.050) U 0.0023 J ND (0.050) ND (0.050) Copper (Dissolved) mg/L ND (0.025) ND (0.025) ND (0.025) ND (0.025) ND (0.025) ND (0.025) Iron (Dissolved) mg/L ND (0.10) ND (0.1) 0.57 1.2 ND (0.10) ND (0.10) Lead (Dissolved) mg/L ND (0.0030) ND (0.003) ND (0.0030) ND (0.003) ND (0.0030) ND (0.0030) Manganese (Dissolved) mg/L 0.26 0.71 1.5 1.2 0.52 0.51 Mercury (Dissolved) mg/L ND (0.00020) UJ ND (0.0002) ND (0.00020) UJ ND (0.0002) ND (0.00020) UJ ND (0.00020) UJNickel (Dissolved) mg/L ND (0.040) ND (0.04) 0.0025 J 0.0038 J ND (0.040) ND (0.040) Selenium (Dissolved) mg/L ND (0.0050) ND (0.005) ND (0.0050) ND (0.005) ND (0.0050) ND (0.0050) Silver (Dissolved) mg/L ND (0.010) ND (0.01) ND (0.010) ND (0.01) ND (0.010) ND (0.010) Thallium (Dissolved) mg/L 0.0085 J ND (0.001) 0.0075 J ND (0.001) 0.0075 J 0.0090 JVanadium (Dissolved) mg/L ND (0.050) ND (0.05) ND (0.050) ND (0.05) ND (0.050) ND (0.050) Zinc (Dissolved) mg/L ND (0.020) ND (0.02) ND (0.020) ND (0.02) ND (0.020) 0.013 J

Semi-Volatiles

2,2'-oxybis(1-Chloropropane) (bis(2-chloroisopropyl) ether) ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4,5-Trichlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4,6-Trichlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4-Dichlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4-Dimethylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,4-Dinitrophenol ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 2,4-Dinitrotoluene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2,6-Dinitrotoluene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Chloronaphthalene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Chlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Methylnaphthalene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Methylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 2-Nitroaniline ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 2-Nitrophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 3,3'-Dichlorobenzidine ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 3-Nitroaniline ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 4,6-Dinitro-2-methylphenol ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) 4-Bromophenyl phenyl ether ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Chloro-3-methylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Chloroaniline ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Chlorophenyl phenyl ether ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Methylphenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) 4-Nitroaniline ug/L ND (50) ND (50) UJ ND (50) ND (50) ND (50) ND (50) 4-Nitrophenol ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) Acenaphthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Acenaphthylene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Acetophenone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Anthracene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Atrazine ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzaldehyde ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(a)anthracene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(a)pyrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(b)fluoranthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(g,h,i)perylene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Benzo(k)fluoranthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Biphenyl ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) bis(2-Chloroethoxy)methane ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10)

CRA 013968 (32)

Page 90: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.6

ANALYTICAL RESULTS SUMMARYON-SITE SEEP SAMPLES - COMPLETE ANALYTICAL RESULTS

Page 3 of 4

Sample Location: SW-X216Y274 SW-X216Y274 SW-X243Y232 SW-X243Y232 SW-X256Y260 SW-X256Y260Sample ID: SW-031502-JW-1428 SW-052102-JW-5042 SW-031502-JW-1426 SW-052102-JW-5041 SW-031502-JW-1427 SW-031502-JW-1427ASample Date: 3/15/2002 5/21/2002 3/15/2002 5/21/2002 3/15/2002 3/15/2002

Duplicate

Parameter Unit

bis(2-Chloroethyl)ether ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) bis(2-Ethylhexyl)phthalate ug/L ND (10) ND (10) ND (10) ND (10) 2.9 J ND (10) Butyl benzylphthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Caprolactam ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Carbazole ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Chrysene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Dibenz(a,h)anthracene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Dibenzofuran ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Diethyl phthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Dimethyl phthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Di-n-butylphthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Di-n-octyl phthalate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Fluoranthene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Fluorene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Hexachlorobenzene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Hexachlorobutadiene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Hexachlorocyclopentadiene ug/L ND (50) ND (50) ND (50) ND (50) ND (50) ND (50) Hexachloroethane ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Indeno(1,2,3-cd)pyrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Isophorone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Naphthalene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Nitrobenzene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) N-Nitrosodi-n-propylamine ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) N-Nitrosodiphenylamine ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Pentachlorophenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Phenanthrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Phenol ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Pyrene ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10)

Volatiles

1,1,1-Trichloroethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,1,2,2-Tetrachloroethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,1,2-Trichloroethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,1-Dichloroethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,1-Dichloroethene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,2,4-Trichlorobenzene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,2-Dibromo-3-chloropropane (DBCP) ug/L ND (2.0) ND (2) ND (2.0) ND (2) ND (2.0) ND (2.0) 1,2-Dibromoethane (Ethylene Dibromide) ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,2-Dichlorobenzene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,2-Dichloroethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,2-Dichloropropane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) 1,3-Dichlorobenzene ug/L 0.15 J ND (1) 0.90 J 0.81 J ND (1.0) ND (1.0) 1,4-Dichlorobenzene ug/L 0.29 J 0.27 J 1.6 1.5 ND (1.0) ND (1.0) 2-Butanone (Methyl Ethyl Ketone) ug/L ND (10) UJ ND (10) ND (10) ND (10) ND (10) UJ ND (10) UJ2-Hexanone ug/L ND (10) UJ ND (10) UJ ND (10) ND (10) UJ ND (10) UJ ND (10) UJ4-Methyl-2-pentanone ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Acetone ug/L ND (10) UJ ND (10) UJ ND (10) U ND (10) UJ ND (10) UJ ND (10) UJBenzene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Bromodichloromethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Bromoform ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Bromomethane (Methyl Bromide) ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Carbon disulfide ug/L ND (1.0) 0.37 J ND (1.0) ND (1) ND (1.0) ND (1.0) Carbon tetrachloride ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Chlorobenzene ug/L 0.18 J 0.29 J 0.48 J 0.49 J ND (1.0) ND (1.0) Chloroethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0)

CRA 013968 (32)

Page 91: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 6.6

ANALYTICAL RESULTS SUMMARYON-SITE SEEP SAMPLES - COMPLETE ANALYTICAL RESULTS

Page 4 of 4

Sample Location: SW-X216Y274 SW-X216Y274 SW-X243Y232 SW-X243Y232 SW-X256Y260 SW-X256Y260Sample ID: SW-031502-JW-1428 SW-052102-JW-5042 SW-031502-JW-1426 SW-052102-JW-5041 SW-031502-JW-1427 SW-031502-JW-1427ASample Date: 3/15/2002 5/21/2002 3/15/2002 5/21/2002 3/15/2002 3/15/2002

Duplicate

Parameter Unit

Chloroform (Trichloromethane) ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Chloromethane (Methyl Chloride) ug/L ND (1.0) UJ ND (1) ND (1.0) ND (1) ND (1.0) UJ ND (1.0) UJcis-1,2-Dichloroethene ug/L ND (0.50) ND (0.5) 1.2 1.9 ND (0.50) ND (0.50) cis-1,3-Dichloropropene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Cyclohexane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Dibromochloromethane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Dichlorodifluoromethane (CFC-12) ug/L ND (1.0) UJ ND (1) ND (1.0) UJ ND (1) ND (1.0) UJ ND (1.0) UJEthylbenzene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Isopropylbenzene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Methyl acetate ug/L ND (10) ND (10) ND (10) ND (10) ND (10) ND (10) Methyl cyclohexane ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Methyl Tert Butyl Ether ug/L ND (5.0) ND (5) ND (5.0) ND (5) ND (5.0) ND (5.0) Methylene chloride ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Styrene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Tetrachloroethene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Toluene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) trans-1,2-Dichloroethene ug/L ND (0.50) ND (0.5) 0.15 J 0.28 J ND (0.50) ND (0.50) trans-1,3-Dichloropropene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Trichloroethene ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Trichlorofluoromethane (CFC-11) ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Trifluorotrichloroethane (Freon 113) ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0) Vinyl chloride ug/L ND (1.0) ND (1) 0.56 J 0.71 J ND (1.0) ND (1.0) Xylene (total) ug/L ND (1.0) ND (1) ND (1.0) ND (1) ND (1.0) ND (1.0)

General Chemistry

Ammonia mg/L -- 0.4 -- 0.1 J -- --pH (water) none -- 8 -- 7.6 -- --Total Dissolved Solids (TDS) mg/L -- 890 -- 980 -- --Total Kjeldahl Nitrogen (TKN) mg/L -- 2 -- 3 -- --Total Suspended Solids (TSS) mg/L -- 960 -- ND (4) -- --

Notes:* = The reported results are in "ug/L" or "ug"J = The reported laboratory result is qualified as an estimated valueUJ = Non-detect. The associated value is estimated.R = Rejected.

CRA 013968 (32)

Page 92: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 1 of 314

Sample Location: 001(P004) 002(P004) 003(P004) 004(P004) 005(P004) 005(P004) 006(P004) 007Sample ID: S-04-011602-LM-001 S-04-011602-LM-002 S-04-011602-LM-003 S-04-011602-LM-004 S-04-011602-LM-005 S-04-011602-LM-005A S-04-011602-LM-006 S-04-011602-LM-007Sample Date: 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002Sample Depth: (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43) Aroclor-1221 (PCB-1221) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43) Aroclor-1232 (PCB-1232) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43) Aroclor-1242 (PCB-1242) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43) Aroclor-1248 (PCB-1248) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43) Aroclor-1254 (PCB-1254) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43) Aroclor-1260 (PCB-1260) ug/Kg ND (43) ND (44) ND (44) ND (44) ND (45) ND (44) ND (45) ND (43)

Sum of Detected PCBs (ND=0) ug/Kg 0 0 0 0 0 0 0 0

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 93: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 2 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

008 009 010 010 011 012 013 014 015S-04-011602-LM-008 S-04-011602-LM-009 S-04-011602-LM-010 S-04-011602-LM-010A S-04-011602-LM-011 S-04-011602-LM-012 S-04-011602-LM-013 S-04-011602-LM-014 S-04-011602-LM-015

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (42) ND (42) ND (42) ND (42) ND (41) ND (44) ND (41) ND (41) ND (42) ND (42) ND (42) ND (42) ND (42) ND (41) ND (44) ND (41) ND (41) ND (42) ND (42) ND (42) ND (42) ND (42) ND (41) ND (44) ND (41) ND (41) ND (42) ND (42) ND (42) ND (42) ND (42) ND (41) 12 J ND (41) ND (41) 8.2 JND (42) ND (42) ND (42) ND (42) ND (41) ND (44) ND (41) ND (41) ND (42) ND (42) ND (42) ND (42) ND (42) ND (41) ND (44) ND (41) ND (41) ND (42) ND (42) 15 J ND (42) ND (42) ND (41) ND (44) ND (41) ND (41) ND (42)

0 15 J 0 0 0 12 J 0 0 8.2 J

13968-32-T91.xls

Page 94: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 3 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

016 017 018 019 020 021 022 023 024S-04-011602-LM-016 S-04-011602-LM-017 S-04-011602-LM-018 S-04-011602-LM-019 S-04-011602-LM-020 S-04-011602-LM-021 S-04-011602-LM-022 S-04-011602-LM-023 S-04-011602-LM-024

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (45) ND (43) ND (43) ND (43) ND (45) ND (42) ND (44) ND (47) ND (50) ND (45) ND (43) ND (43) ND (43) ND (45) ND (42) ND (44) ND (47) ND (50) ND (45) ND (43) ND (43) ND (43) ND (45) ND (42) ND (44) ND (47) ND (50) ND (45) ND (43) ND (43) ND (43) ND (45) ND (42) ND (44) 24 J 25 JND (45) ND (43) ND (43) ND (43) 11 J ND (42) ND (44) ND (47) ND (50) ND (45) ND (43) ND (43) ND (43) ND (45) ND (42) ND (44) ND (47) ND (50) ND (45) ND (43) ND (43) ND (43) ND (45) ND (42) ND (44) ND (47) ND (50)

0 0 0 0 11 J 0 0 24 J 25 J

13968-32-T91.xls

Page 95: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 4 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

025 026 027 027 028 028 029 029S-04-011602-LM-025 S-04-011602-LM-026 S-04-011602-LM-027 S-04-011602-LM-027A S-04-011602-LM-028 S-04-011602-LM-028A S-04-011602-LM-029 S-04-011602-LM-029A

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0.33-0.66)

Duplicate

ND (53) ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42) ND (53) ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42) ND (53) ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42)

320 ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42) ND (53) ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42) ND (53) ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42) ND (53) ND (49) ND (48) ND (44) ND (44) ND (44) ND (44) ND (42)

320 0 0 0 0 0 0 0

13968-32-T91.xls

Page 96: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 5 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

029 030 031 032 033 033 035 036S-04-011602-LM-029B S-04-011602-LM-030 S-04-011602-LM-031 S-04-011602-LM-032 S-04-011602-LM-033 S-04-011602-LM-033A S-04-011602-LM-035 S-04-011602-LM-036

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0.66-1) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33)

ND (42) ND (43) ND (41) ND (40) ND (52) ND (44) ND (47) ND (57) ND (42) ND (43) ND (41) ND (40) ND (52) ND (44) ND (47) ND (57) ND (42) ND (43) ND (41) ND (40) ND (52) ND (44) ND (47) ND (57) ND (42) ND (43) ND (41) ND (40) ND (52) ND (44) ND (47) 45 JND (42) ND (43) ND (41) ND (40) 18 J ND (44) ND (47) ND (57) ND (42) ND (43) ND (41) ND (40) ND (52) ND (44) ND (47) ND (57) ND (42) ND (43) ND (41) ND (40) ND (52) ND (44) ND (47) ND (57)

0 0 0 0 18 J 0 0 45 J

13968-32-T91.xls

Page 97: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 6 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

037 038 039 040 041 042 043 043S-04-011602-LM-037 S-04-011602-LM-038 S-04-011602-LM-039 S-04-011602-LM-040 S-04-011602-LM-041 S-04-011602-LM-042 S-04-011602-LM-043 S-04-011602-LM-043A

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (100) ND (420) ND (52) ND (45) ND (43) ND (46) ND (48) ND (44) ND (100) ND (420) ND (52) ND (45) ND (43) ND (46) ND (48) ND (44) ND (100) ND (420) ND (52) ND (45) ND (43) ND (46) ND (48) ND (44)

4000 ND (420) 11 J ND (45) ND (43) ND (46) 12 J 9.3 JND (100) 9800 ND (52) ND (45) 36 J ND (46) ND (48) ND (44) ND (100) ND (420) ND (52) 7.2 J ND (43) ND (46) ND (48) ND (44) ND (100) ND (420) ND (52) ND (45) ND (43) ND (46) ND (48) ND (44)

4,000 9,800 11 J 7.2 J 36 J 0 12 J 9.3 J

13968-32-T91.xls

Page 98: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 7 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

044 045 045 045 046 047 048 049S-04-011602-LM-044 S-04-011602-LM-045 S-04-011602-LM-045A S-04-011602-LM-045B S-04-011602-LM-046 S-04-011602-LM-047 S-04-011602-LM-048 S-04-011602-LM-049

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0.33-0.66) (0.66-1) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (44) ND (42) ND (42) ND (42) ND (43) ND (44) ND (44) ND (41) ND (44) ND (42) ND (42) ND (42) ND (43) ND (44) ND (44) ND (41) ND (44) ND (42) ND (42) ND (42) ND (43) ND (44) ND (44) ND (41) ND (44) 7.6 J ND (42) ND (42) 47 14 J 850 1400 ND (44) ND (42) ND (42) ND (42) ND (43) ND (44) ND (44) ND (41) ND (44) ND (42) ND (42) ND (42) 35 J ND (44) ND (44) ND (41) ND (44) ND (42) ND (42) ND (42) ND (43) ND (44) 620 ND (41)

0 7.6 J 0 0 82 J 14 J 1,470 1,400

13968-32-T91.xls

Page 99: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 8 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

050 051 052 053 054 055 055 056 057S-04-011602-LM-050 S-04-011602-LM-051 S-04-011602-LM-052 S-04-011602-LM-053 S-04-011602-LM-054 S-04-011602-LM-055 S-04-011602-LM-055A S-04-011602-LM-056 S-04-011602-LM-057

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33)

ND (40) ND (58) ND (45) ND (43) ND (47) ND (47) ND (43) ND (53) ND (50) ND (40) ND (58) ND (45) ND (43) ND (47) ND (47) ND (43) ND (53) ND (50) ND (40) ND (58) ND (45) ND (43) ND (47) ND (47) ND (43) ND (53) ND (50)

130 17 J ND (45) ND (43) 24 J 17 J ND (43) 9.4 J 24 JND (40) ND (58) ND (45) ND (43) ND (47) ND (47) ND (43) ND (53) ND (50)

48 ND (58) 8.3 J ND (43) ND (47) ND (47) ND (43) ND (53) ND (50) ND (40) ND (58) ND (45) ND (43) ND (47) ND (47) ND (43) ND (53) ND (50)

178 17 J 8.3 J 0 24 J 17 J 0 9.4 J 24 J

13968-32-T91.xls

Page 100: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 9 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

057 058 059 060 061 062 063 064S-04-011602-LM-057A S-04-011602-LM-058 S-04-011602-LM-059 S-04-011602-LM-060 S-04-011602-LM-061 S-04-011602-LM-062 S-04-011602-LM-063 S-04-011602-LM-064

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (51) ND (49) ND (45) ND (5100) ND (43) ND (42) ND (43) ND (56) ND (51) ND (49) ND (45) ND (5100) ND (43) ND (42) ND (43) ND (56) ND (51) ND (49) ND (45) ND (5100) ND (43) ND (42) ND (43) ND (56) ND (51) 23 J ND (45) ND (5100) ND (43) 70 ND (43) 23 J

170 ND (49) ND (45) 140000 1100 ND (42) ND (43) ND (56) ND (51) ND (49) 160 ND (5100) ND (43) ND (42) ND (43) ND (56) ND (51) ND (49) ND (45) 38000 500 ND (42) ND (43) ND (56)

170 23 J 160 178,000 1,600 70 0 23 J

13968-32-T91.xls

Page 101: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 10 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

065 065 066 067 068 069 069 070S-04-011602-LM-065 S-04-011602-LM-065A S-04-011602-LM-066 S-04-011602-LM-067 S-04-011602-LM-068 S-04-011602-LM-069 S-04-011602-LM-069A S-04-011602-LM-070

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (46) ND (45) ND (47) ND (43) ND (43) ND (2200) ND (880) ND (9700) ND (46) ND (45) ND (47) ND (43) ND (43) ND (2200) ND (880) ND (9700) ND (46) ND (45) ND (47) ND (43) ND (43) ND (2200) ND (880) ND (9700) ND (46) 15 J 22 J 9.6 J 22 J ND (2200) ND (880) ND (9700) ND (46) ND (45) ND (47) ND (43) ND (43) 22000 8800 350000

12 J ND (45) ND (47) ND (43) ND (43) ND (2200) ND (880) ND (9700) ND (46) ND (45) ND (47) ND (43) ND (43) ND (2200) ND (880) 42000

12 J 15 J 22 J 9.6 J 22 J 22,000 8,800 392,000

13968-32-T91.xls

Page 102: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 11 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

071 072 073 074 074 075 076 077 078S-04-011602-LM-071 S-04-011602-LM-072 S-04-011602-LM-073 S-04-011602-LM-074 S-04-011602-LM-074A S-04-011602-LM-075 S-04-011602-LM-076 S-04-011602-LM-077 S-04-011502-LM-78

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (43) ND (45) ND (43) ND (45) ND (45000) ND (44) ND (44) ND (96) ND (44) ND (43) ND (45) ND (43) ND (45) ND (45000) ND (44) ND (44) ND (96) ND (44) ND (43) ND (45) ND (43) ND (45) ND (45000) ND (44) ND (44) ND (96) ND (44) 41 J ND (45) ND (43) ND (45) ND (45000) ND (44) ND (44) ND (96)

730 ND (43) 16 J 1100 600 660000 930 ND (44) 430 ND (44) ND (43) ND (45) ND (43) ND (45) ND (45000) ND (44) ND (44) ND (96)

300 ND (43) ND (45) ND (43) ND (45) ND (45000) ND (44) ND (44) 85 J

1,030 41 J 16 J 1,100 600 660,000 930 0 515 J

13968-32-T91.xls

Page 103: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 12 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

079 080 080 080 081 081 082 082 083S-04-011502-LM-79 S-04-011502-LM-80 S-04-011602-LM-080A S-04-011602-LM-080B S-04-011502-LM-81 S-04-011502-LM-81A S-04-011502-LM-082 S-04-011502-LM-082A S-04-011502-LM-83

1/15/2002 1/15/2002 1/16/2002 1/16/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0.33-0.66) (0.66-1) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (21000) ND (45) ND (41) ND (41) ND (440) ND (40) ND (45) ND (46) ND (44) ND (21000) ND (45) ND (41) ND (41) ND (440) ND (40) ND (45) ND (46) ND (44) ND (21000) ND (45) ND (41) ND (41) ND (440) ND (40) ND (45) ND (46) ND (44) ND (21000) ND (45) 66 8.3 J ND (440) ND (40) ND (45) ND (46) ND (44)

120000 170 ND (41) ND (41) 2700 60 99 220 ND (44) ND (21000) ND (45) ND (41) ND (41) ND (440) ND (40) ND (45) ND (46) ND (44)

9800 J 56 ND (41) ND (41) 890 17 J 23 J ND (46) ND (44)

129,800 J 226 66 8.3 J 3,590 77 J 122 J 220 0

13968-32-T91.xls

Page 104: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 13 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

084 085 086 087 088 089 089 090 090S-04-011502-LM-84 S-04-011502-LM-85 S-04-011502-LM-86 S-04-011502-LM-87 S-04-011502-LM-88 S-04-011502-LM-089 S-04-011502-LM-089A S-04-011502-LM-090 S-04-011502-LM-090A

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2)

Duplicate

ND (47) ND (7600) ND (230) ND (45) ND (47) ND (240) ND (230) ND (450) ND (440) ND (47) ND (7600) ND (230) ND (45) ND (47) ND (240) ND (230) ND (450) ND (440) ND (47) ND (7600) ND (230) ND (45) ND (47) ND (240) ND (230) ND (450) ND (440) ND (47) ND (7600) ND (230) ND (45) ND (47) ND (240) ND (230) ND (450) ND (440)

39 J 58000 960 120 160 1900 1200 6100 5100 ND (47) ND (7600) ND (230) ND (45) ND (47) ND (240) ND (230) ND (450) ND (440) ND (47) 3300 J 150 J 39 J 47 160 J 87 J 780 610

39 J 61,300 J 1110 J 159 J 207 2,060 J 1,287 J 6,880 5,710

13968-32-T91.xls

Page 105: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 14 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

091 092 093 094 095 096 097 098(P004) 099S-04-011502-LM-091 S-04-011502-LM-092 S-04-011502-LM-093 S-04-011502-LM-094 S-04-011502-LM-095 S-04-011502-LM-096 S-04-011502-LM-097 S-04-011502-LM-098 S-04-011502-LM-099

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (41) ND (46) ND (44) ND (49) ND (860) ND (920) ND (45) ND (48) ND (50) ND (41) ND (46) ND (44) ND (49) ND (860) ND (920) ND (45) ND (48) ND (50) ND (41) ND (46) ND (44) ND (49) ND (860) ND (920) ND (45) ND (48) ND (50) ND (41) ND (46) 90 ND (49) ND (860) ND (920) ND (45) ND (48) ND (50)

150 160 ND (44) 110 5700 7800 400 110 120 ND (41) ND (46) ND (44) ND (49) ND (860) ND (920) ND (45) ND (48) ND (50)

20 J 22 J ND (44) ND (49) 610 J 660 J ND (45) 15 J 19 J

170 J 182 J 90 110 6,310 J 8,460 J 400 125 J 139 J

13968-32-T91.xls

Page 106: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 15 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

100 101 102 103 103 104 104 105 106S-04-011502-LM-100 S-04-011502-LM-101 S-04-011502-LM-102 S-04-011502-LM-103 S-04-011502-LM-103A S-04-011502-LM-104 S-04-011502-LM-104A S-04-011502-LM-105 S-04-011502-LM-106

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (49) ND (4400) ND (210) ND (47) ND (48) ND (48) ND (47) ND (43) ND (250) ND (49) ND (4400) ND (210) ND (47) ND (48) ND (48) ND (47) ND (43) ND (250) ND (49) ND (4400) ND (210) ND (47) ND (48) ND (48) ND (47) ND (43) ND (250) ND (49) ND (4400) ND (210) ND (47) ND (48) ND (48) ND (47) ND (43) ND (250)

310 38000 920 64 100 190 J 290 J 480 2000 ND (49) ND (4400) ND (210) ND (47) ND (48) ND (48) ND (47) ND (43) ND (250)

55 2200 J 150 J ND (47) 23 J 34 J 54 J 63 210 J

365 40,200 J 1,070 J 64 123 J 224 J 344 J 543 2,210 J

13968-32-T91.xls

Page 107: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 16 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

106 107 108 109 110 111 111 112 113S-04-011502-LM-106A S-04-011502-LM-107 S-04-011502-LM-108 S-04-011502-LM-109 S-04-011502-LM-110 S-04-011502-LM-111 S-04-011502-LM-111A S-04-011502-LM-112 S-04-011502-LM-113

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (41) ND (44) ND (99) ND (42) ND (4700) ND (46) ND (46) ND (43) ND (47) ND (41) ND (44) ND (99) ND (42) ND (4700) ND (46) ND (46) ND (43) ND (47) ND (41) ND (44) ND (99) ND (42) ND (4700) ND (46) ND (46) ND (43) ND (47) ND (41) ND (44) ND (99) ND (42) ND (4700) ND (46) ND (46) ND (43) ND (47)

65 360 160 72 27000 360 200 42 J 290 ND (41) ND (44) ND (99) ND (42) ND (4700) ND (46) ND (46) ND (43) ND (47) ND (41) 51 ND (99) ND (42) 1400 J 36 J 37 J ND (43) 34 J

65 411 160 72 28,400 J 396 J 237 J 42 J 324 J

13968-32-T91.xls

Page 108: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 17 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

113 114 115 116 117 118 119 120 121S-04-011502-LM-113A S-04-011502-LM-114 S-04-011502-LM-115 S-04-011502-LM-116 S-04-011502-LM-117 S-04-011502-LM-118 S-04-011502-LM-119 S-04-011502-LM-120 S-04-011502-LM-121

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0.33-1) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (84) ND (2200) ND (490) ND (48) ND (450) ND (8800) ND (430) ND (100) ND (470000) ND (84) ND (2200) ND (490) ND (48) ND (450) ND (8800) ND (430) ND (100) ND (470000) ND (84) ND (2200) ND (490) ND (48) ND (450) ND (8800) ND (430) ND (100) ND (470000) ND (84) ND (2200) ND (490) ND (48) ND (450) ND (8800) ND (430) ND (100) ND (470000)

450 12000 2900 350 3900 49000 490 720 3300000 ND (84) ND (2200) ND (490) ND (48) ND (450) ND (8800) ND (430) ND (100) ND (470000)

60 J 850 J 330 J ND (48) 410 ND (8800) ND (430) 64 ND (470000)

510 J 12,850 J 3,230 J 350 4,310 49,000 490 784 3,300,000

13968-32-T91.xls

Page 109: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 18 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

122 123 124 125 126 127 127 128 129S-04-011502-LM-122 S-04-011502-LM-123 S-04-011502-LM-124 S-04-011502-LM-125 S-04-011502-LM-126 S-04-011502-LM-127 S-04-011502-LM-127A S-04-011502-LM-128 S-04-011502-LM-129

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44000) ND (92) ND (240) ND (930) ND (24000) ND (46) ND (45) ND (44) ND (220000) ND (44000) ND (92) ND (240) ND (930) ND (24000) ND (46) ND (45) ND (44) ND (220000) ND (44000) ND (92) ND (240) ND (930) ND (24000) ND (46) ND (45) ND (44) ND (220000) ND (44000) ND (92) ND (240) ND (930) ND (24000) ND (46) ND (45) ND (44) ND (220000)

650000 340 1400 15000 290000 200 330 300 1900000 ND (44000) ND (92) ND (240) ND (930) ND (24000) ND (46) ND (45) ND (44) ND (220000)

25000 43 150 1100 13000 ND (46) 50 29 J 85000 J

675,000 383 1,550 16,100 303,000 200 380 329 J 1,985,000 J

13968-32-T91.xls

Page 110: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 19 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

130 131 132 132 133 133 134 134S-04-011502-LM-130 S-04-011502-LM-131 S-04-011502-LM-132A S-04-011502-LM-132 S-04-011502-LM-133A S-04-011502-LM-133 S-04-011502-LM-134A S-04-011502-LM-134

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0.33-0.66) (0-0.33) (0.33-2) (0-0.33) (0.33-0.54)

ND (26000) ND (230) ND (110) ND (43) ND (2500) ND (40000) ND (230) ND (45) ND (26000) ND (230) ND (110) ND (43) ND (2500) ND (40000) ND (230) ND (45) ND (26000) ND (230) ND (110) ND (43) ND (2500) ND (40000) ND (230) ND (45) ND (26000) ND (230) ND (110) ND (43) ND (2500) ND (40000) ND (230) ND (45)

250000 1200 1300 8.8 J 41000 540000 1500 160 ND (26000) ND (230) ND (110) ND (43) ND (2500) ND (40000) ND (230) ND (45)

13000 J 110 J 130 ND (43) 2200 J 17000 J ND (230) 22 J

263,000 J 1310 J 1430 8.8 J 43,200 J 557,000 J 1,500 182 J

13968-32-T91.xls

Page 111: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 20 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

135 135 136 136 137 138 139 140 141S-04-011502-LM-135A S-04-011502-LM-135 S-04-011502-LM-136 S-04-011502-LM-136A S-04-011502-LM-137 S-04-011502-LM-138 S-04-011502-LM-139 S-04-011502-LM-140 S-04-011502-LM-141

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (90) ND (45) ND (100) ND (250) ND (460) ND (91) ND (45) ND (49) ND (460) ND (90) ND (45) ND (100) ND (250) ND (460) ND (91) ND (45) ND (49) ND (460) ND (90) ND (45) ND (100) ND (250) ND (460) ND (91) ND (45) ND (49) ND (460) ND (90) ND (45) ND (100) ND (250) ND (460) ND (91) ND (45) ND (49) ND (460)

920 40 J 720 1200 3200 700 410 640 3800 ND (90) ND (45) ND (100) ND (250) ND (460) ND (91) ND (45) ND (49) ND (460)

130 ND (45) 94 J 150 J 390 J 88 J 65 110 ND (460)

1,050 40 J 814 J 1,350 J 3,590 J 788 J 475 750 3,800

13968-32-T91.xls

Page 112: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 21 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

142 143 144 145 146 147 148 148 149S-04-011502-LM-142 S-04-011502-LM-143 S-04-011502-LM-144 S-04-011502-LM-145 S-04-011502-LM-146 S-04-011502-LM-147 S-04-011502-LM-148 S-04-011502-LM-148A S-04-011502-LM-149

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (910) ND (46) ND (51) ND (110) ND (3500) ND (430) ND (4200) ND (8300) ND (520) ND (910) ND (46) ND (51) ND (110) ND (3500) ND (430) ND (4200) ND (8300) ND (520) ND (910) ND (46) ND (51) ND (110) ND (3500) ND (430) ND (4200) ND (8300) ND (520) ND (910) ND (46) ND (51) ND (110) ND (3500) ND (430) ND (4200) ND (8300) ND (520)

11000 560 120 1400 21000 5200 69000 150000 9900 ND (910) ND (46) ND (51) ND (110) ND (3500) ND (430) ND (4200) ND (8300) ND (520)

1600 90 ND (51) ND (110) ND (3500) ND (430) ND (4200) 7700 J 1200

12,600 650 120 1,400 21,000 5,200 69,000 157,700 J 11,100

13968-32-T91.xls

Page 113: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 22 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

150 151 152 152 153 154 155 156 157S-04-011502-LM-150 S-04-011502-LM-151 S-04-011502-LM-152 S-04-011502-LM-152A S-04-011602-LM-153 S-04-011602-LM-154 S-04-011602-LM-155 S-04-011602-LM-156 S-04-011602-LM-157

1/15/2002 1/15/2002 1/15/2002 1/15/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (490) ND (490) ND (43) ND (43) ND (48) ND (43) ND (47) ND (47) ND (43) ND (490) ND (490) ND (43) ND (43) ND (48) ND (43) ND (47) ND (47) ND (43) ND (490) ND (490) ND (43) ND (43) ND (48) ND (43) ND (47) ND (47) ND (43) ND (490) ND (490) ND (43) ND (43) 54 180 40 J 54 83

4000 2500 21 J ND (43) ND (48) ND (43) ND (47) ND (47) ND (43) ND (490) ND (490) ND (43) ND (43) ND (48) ND (43) ND (47) ND (47) ND (43) ND (490) 1400 ND (43) ND (43) ND (48) ND (43) ND (47) ND (47) ND (43)

4,000 3,900 21 J 0 54 180 40 J 54 83

13968-32-T91.xls

Page 114: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 23 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

157 158 158 159 159 160 160 160S-04-011602-LM-157A S-04-011602-LM-158 S-04-011602-LM-158A S-04-011602-LM-159 S-04-011602-LM-159A S-04-011602-LM-160 S-04-011602-LM-160A S-04-011602-LM-160AD

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-1.67) (0-0.33) (0.33-1.08) (0.33-1.08)

Duplicate

ND (41) ND (46) ND (40) ND (47) ND (42) ND (47) ND (46) ND (49) ND (41) ND (46) ND (40) ND (47) ND (42) ND (47) ND (46) ND (49) ND (41) ND (46) ND (40) ND (47) ND (42) ND (47) ND (46) ND (49)

6.2 J 510 170 160 ND (42) 21 J 9.5 J 42 JND (41) ND (46) ND (40) ND (47) ND (42) ND (47) ND (46) ND (49) ND (41) ND (46) ND (40) ND (47) ND (42) ND (47) ND (46) ND (49) ND (41) ND (46) ND (40) ND (47) ND (42) ND (47) ND (46) ND (49)

6.2 J 510 170 160 0 21 J 9.5 J 42 J

13968-32-T91.xls

Page 115: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 24 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

161 162 163 164 165 165 166 167 168S-04-011602-LM-161 S-04-011602-LM-162 S-04-011602-LM-163 S-04-011602-LM-164 S-04-011602-LM-165 S-04-011602-LM-165A S-04-011602-LM-166 S-04-011602-LM-167 S-04-011602-LM-168

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (230) ND (8600) ND (47) ND (470) ND (490) ND (450) ND (43) ND (51) ND (46) ND (230) ND (8600) ND (47) ND (470) ND (490) ND (450) ND (43) ND (51) ND (46) ND (230) ND (8600) ND (47) ND (470) ND (490) ND (450) ND (43) ND (51)

99 J 3400 J ND (8600) 100 5400 5300 4300 520 20 JND (46) ND (230) 77000 ND (47) ND (470) ND (490) ND (450) ND (43) ND (51)

97 J ND (230) ND (8600) ND (47) ND (470) ND (490) ND (450) ND (43) ND (51) ND (46) ND (230) ND (8600) ND (47) ND (470) ND (490) ND (450) ND (43) ND (51)

196 J 3,400 J 77,000 100 5,400 5,300 4,300 520 20 J

13968-32-T91.xls

Page 116: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 25 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

169 170 171 172 173 174 175 176 201S-04-011602-LM-169 S-04-011602-LM-170 S-04-011602-LM-171 S-04-011602-LM-172 S-04-011602-LM-173 S-04-011602-LM-174 S-04-011602-LM-175 S-04-011602-LM-176 S-22-011402-LM-201

1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/16/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (260) ND (44) ND (48) ND (52) ND (48) ND (12000) ND (45) ND (48) ND (430) ND (260) ND (44) ND (48) ND (52) ND (48) ND (12000) ND (45) ND (48) ND (430) ND (260) ND (44) ND (48) ND (52) ND (48) ND (12000) ND (45) ND (48) ND (430)

3400 J 1300 52 170 75 ND (12000) ND (45) 110 ND (430) ND (260) ND (44) ND (48) ND (52) ND (48) 160000 730 ND (48) 2300 ND (260) ND (44) ND (48) ND (52) ND (48) ND (12000) ND (45) ND (48) ND (430) ND (260) ND (44) ND (48) ND (52) ND (48) ND (12000) ND (45) 56 520

3,400 J 1,300 52 170 75 160,000 730 166 2,820

13968-32-T91.xls

Page 117: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 26 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

202 202 203 204 205 206 207 208S-22-011402-LM-202 S-22-011402-LM-202A S-22-011402-LM-203 S-22-011402-LM-204 S-22-011402-LM-205 S-22-011402-LM-206 S-22-011402-LM-207 S-22-011402-LM-208

1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (460) ND (480) ND (46) ND (44) ND (50) ND (830) ND (820) ND (2400) ND (460) ND (480) ND (46) ND (44) ND (50) ND (830) ND (820) ND (2400) ND (460) ND (480) ND (46) ND (44) ND (50) ND (830) ND (820) ND (2400) ND (460) ND (480) ND (46) ND (44) ND (50) ND (830) ND (820) ND (2400)

1800 3500 79 ND (44) 41 J 13000 9500 37000 ND (460) ND (480) ND (46) ND (44) ND (50) ND (830) ND (820) ND (2400)

200 J ND (480) ND (46) ND (44) ND (50) 940 840 ND (2400)

2,000 J 3,500 79 0 41 J 13,940 10,340 37,000

13968-32-T91.xls

Page 118: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 27 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

209 209 210 211 211 212 212 213S-22-011402-LM-209 S-22-011702-LM-209A S-22-011402-LM-210 S-22-011402-LM-211 S-22-011702-LM-211A S-22-011402-LM-212 S-22-011702-LM-212A S-22-011402-LM-213

1/14/2002 1/17/2002 1/14/2002 1/14/2002 1/17/2002 1/14/2002 1/17/2002 1/14/2002(0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33)

ND (44) ND (49) ND (100) ND (820) ND (8700) ND (200) ND (210) ND (47) ND (44) ND (49) ND (100) ND (820) ND (8700) ND (200) ND (210) ND (47) ND (44) ND (49) ND (100) ND (820) ND (8700) ND (200) ND (210) ND (47) ND (44) ND (49) ND (100) ND (820) ND (8700) ND (200) ND (210) ND (47)

81 110 410 12000 96000 720 1000 31 JND (44) ND (49) ND (100) ND (820) ND (8700) ND (200) ND (210) ND (47) ND (44) 25 J 68 J 750 J 7200 J 85 J 120 J ND (47)

81 135 J 478 J 12,750 J 103,200 J 805 J 1,120 J 31 J

13968-32-T91.xls

Page 119: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 28 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

214 215 216 217 218 219 220 221 222S-22-011402-LM-214 S-22-011402-LM-215 S-22-011402-LM-216 S-22-011402-LM-217 S-22-011402-LM-218 S-22-011402-LM-219 S-22-011402-LM-220 S-22-011402-LM-221 S-22-011402-LM-222

1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (4300) ND (200) ND (910) ND (45) ND (210) ND (2200) ND (820) ND (460) ND (240) ND (4300) ND (200) ND (910) ND (45) ND (210) ND (2200) ND (820) ND (460) ND (240) ND (4300) ND (200) ND (910) ND (45) ND (210) ND (2200) ND (820) ND (460) ND (240) ND (4300) ND (200) ND (910) ND (45) ND (210) ND (2200) ND (820) ND (460) ND (240)

36000 760 12000 ND (45) 590 15000 5900 3400 ND (240) ND (4300) ND (200) ND (910) ND (45) ND (210) ND (2200) ND (820) ND (460) 340

3400 J 140 J 1400 ND (45) 84 J 1300 J 810 J 350 J ND (240)

39,400 J 900 J 13,400 0 674 J 16,300 J 6,710 J 3,750 J 340

13968-32-T91.xls

Page 120: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 29 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

223 224 225 226 227 228 228S-22-011402-LM-223 S-22-011402-LM-224 S-22-011402-LM-225 S-22-011402-LM-226 S-22-011402-LM-227 S-22-011702-LM-228D S-22-011702-LM-228E

1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/17/2002 1/17/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2)

ND (45) ND (4300) ND (49) ND (2300) ND (8300) ND (2100) ND (4100) ND (45) ND (4300) ND (49) ND (2300) ND (8300) ND (2100) ND (4100) ND (45) ND (4300) ND (49) ND (2300) ND (8300) ND (2100) ND (4100) ND (45) ND (4300) ND (49) ND (2300) ND (8300) ND (2100) ND (4100)

9.6 J 32000 36 J 15000 88000 23000 42000 ND (45) ND (4300) ND (49) ND (2300) ND (8300) ND (2100) ND (4100) ND (45) 2700 J ND (49) 1400 J 7600 J 2700 3900 J

9.6 J 34,700 J 36 J 16,400 J 95,600 J 25,700 45,900 J

13968-32-T91.xls

Page 121: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 30 of 314

Sample Location: 228B 228B 228C 228C 229 230 230 231Sample ID: S-22-011402-LM-228B S-22-011702-LM-228BA S-22-011402-LM-228C S-22-011702-LM-228CA S-22-011402-LM-229 S-22-011402-LM-230 S-22-011402-LM-230A S-22-011402-LM-231Sample Date: 1/14/2002 1/17/2002 1/14/2002 1/17/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002Sample Depth: (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (4000) ND (21000) ND (41) ND (50) ND (2100) ND (410) ND (410) ND (46) Aroclor-1221 (PCB-1221) ug/Kg ND (4000) ND (21000) ND (41) ND (50) ND (2100) ND (410) ND (410) ND (46) Aroclor-1232 (PCB-1232) ug/Kg ND (4000) ND (21000) ND (41) ND (50) ND (2100) ND (410) ND (410) ND (46) Aroclor-1242 (PCB-1242) ug/Kg ND (4000) ND (21000) ND (41) ND (50) ND (2100) ND (410) ND (410) ND (46) Aroclor-1248 (PCB-1248) ug/Kg 22000 150000 120 120 24000 3200 2500 180 Aroclor-1254 (PCB-1254) ug/Kg ND (4000) ND (21000) ND (41) ND (50) ND (2100) ND (410) ND (410) ND (46) Aroclor-1260 (PCB-1260) ug/Kg 1600 J 9600 J ND (41) 38 J 2000 J 400 J 320 J ND (46)

Sum of Detected PCBs (ND=0) ug/Kg 23,600 J 159,600 J 120 158 J 26,000 J 3,600 J 2,820 J 180

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 122: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 31 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

232 233 234 235 236 237 237 238S-22-011402-LM-232 S-22-011402-LM-233 S-22-011402-LM-234 S-22-011402-LM-235 S-22-011402-LM-236 S-22-011402-LM-237 S-22-011402-LM-237A S-22-011402-LM-238

1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (410) ND (2300) ND (2100) ND (4500) ND (380) ND (47) ND (46) ND (430) ND (410) ND (2300) ND (2100) ND (4500) ND (380) ND (47) ND (46) ND (430) ND (410) ND (2300) ND (2100) ND (4500) ND (380) ND (47) ND (46) ND (430) ND (410) ND (2300) ND (2100) ND (4500) ND (380) ND (47) ND (46) ND (430)

770 27000 19000 33000 3400 ND (47) 17 J 1700 ND (410) ND (2300) ND (2100) ND (4500) ND (380) ND (47) ND (46) ND (430)

130 J 2500 2700 3000 J 410 ND (47) ND (46) 280 J

900 J 29,500 21,700 36,000 J 3,810 0 17 J 1,980 J

13968-32-T91.xls

Page 123: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 32 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

239 240 241 242 243 244 244 245S-22-011402-LM-239 S-22-011402-LM-240 S-22-011402-LM-241 S-22-011402-LM-242 S-22-011402-LM-243 S-22-011402-LM-244 S-22-011702-LM-244A S-22-011402-LM-245

1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/17/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (22000) ND (4200) ND (4300) ND (4200) ND (41) ND (83) ND (440) ND (800) ND (22000) ND (4200) ND (4300) ND (4200) ND (41) ND (83) ND (440) ND (800) ND (22000) ND (4200) ND (4300) ND (4200) ND (41) ND (83) ND (440) ND (800) ND (22000) ND (4200) ND (4300) ND (4200) ND (41) ND (83) ND (440) ND (800)

130000 66000 37000 54000 91 650 5000 5800 ND (22000) ND (4200) ND (4300) ND (4200) ND (41) ND (83) ND (440) ND (800)

13000 J 4700 5400 5500 ND (41) 91 700 740 J

143,000 J 70,700 42,400 59,500 91 741 5,700 6,540 J

13968-32-T91.xls

Page 124: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 33 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

245 246 246 247 248 249 250 250S-22-011702-LM-245A S-22-011402-LM-246 S-22-011702-LM-246A S-22-011402-LM-247 S-22-011402-LM-248 S-22-011402-LM-249 S-22-011402-LM-250 S-22-011402-LM-250A

1/17/2002 1/14/2002 1/17/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002(0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (5000) ND (42) ND (850) ND (9300) ND (4200) ND (42) ND (42) ND (42) ND (5000) ND (42) ND (850) ND (9300) ND (4200) ND (42) ND (42) ND (42) ND (5000) ND (42) ND (850) ND (9300) ND (4200) ND (42) ND (42) ND (42) ND (5000) ND (42) ND (850) ND (9300) ND (4200) ND (42) ND (42) ND (42)

76000 140 9000 130000 25000 54 36 J 41 JND (5000) ND (42) ND (850) ND (9300) ND (4200) ND (42) ND (42) ND (42)

6800 29 J 1400 10000 3400 J ND (42) ND (42) 12 J

82,800 169 J 10,400 140,000 28,400 J 54 36 J 53 J

13968-32-T91.xls

Page 125: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 34 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

251 252 253 254 255 256 257 258 259S-22-011402-LM-251 S-22-011402-LM-252 S-22-011402-LM-253 S-22-011402-LM-254 S-22-011402-LM-255 S-22-011102-LM-256 S-22-011102-LM-257 S-22-011102-LM-258 S-22-011102-LM-259

1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002 1/11/2002 1/11/2002 1/11/2002 1/11/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (4800) ND (4200) ND (21000) ND (8900) ND (4000) ND (480) ND (47) ND (4900) ND (4300) ND (4800) ND (4200) ND (21000) ND (8900) ND (4000) ND (480) ND (47) ND (4900) ND (4300) ND (4800) ND (4200) ND (21000) ND (8900) ND (4000) ND (480) ND (47) ND (4900) ND (4300) ND (4800) ND (4200) ND (21000) ND (8900) ND (4000) ND (480) ND (47) ND (4900) ND (4300)

43000 30000 120000 95000 47000 3500 96 34000 80000 ND (4800) ND (4200) ND (21000) ND (8900) ND (4000) ND (480) ND (47) ND (4900) ND (4300)

4800 3000 J 8600 J 7300 J 3600 J 410 J ND (47) 4100 J 5200

47,800 33,000 J 128,600 J 102,300 J 50,600 J 3,910 J 96 38,100 J 85,200

13968-32-T91.xls

Page 126: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 35 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

259 260 261 262 263 264 264 264S-22-011102-LM-259A S-22-011102-LM-260 S-22-011102-LM-261 S-22-011102-LM-262 S-22-011102-LM-263 S-22-011102-LM-264 S-22-011402-LM-264A S-22-011402-LM-264B

1/11/2002 1/11/2002 1/11/2002 1/11/2002 1/11/2002 1/11/2002 1/14/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-0.67) (0.67-1)

Duplicate

ND (4400) ND (88) ND (91) ND (4200) ND (24000) ND (85) ND (200) ND (42) ND (4400) ND (88) ND (91) ND (4200) ND (24000) ND (85) ND (200) ND (42) ND (4400) ND (88) ND (91) ND (4200) ND (24000) ND (85) ND (200) ND (42) ND (4400) ND (88) 1000 ND (4200) ND (24000) ND (85) ND (200) ND (42)

45000 430 ND (91) 47000 240000 500 830 150 ND (4400) ND (88) ND (91) ND (4200) ND (24000) ND (85) ND (200) ND (42)

3000 J 64 J ND (91) 4200 13000 J ND (85) 110 J 25 J

48,000 J 494 J 1,000 51,200 253,000 J 500 940 J 175 J

13968-32-T91.xls

Page 127: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 36 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

265 265 265 266 266 266 267 267S-22-011102-LM-265 S-22-011702-LM-265A S-22-011702-LM-265B S-22-011102-LM-266 S-22-011102-LM-266A S-22-011702-LM-266B S-22-011102-LM-267 S-22-011702-LM-267A

1/11/2002 1/17/2002 1/17/2002 1/11/2002 1/11/2002 1/17/2002 1/11/2002 1/17/2002(0.33-2) (0-0.33) (0-0.33) (0.33-2) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

Duplicate Duplicate

ND (810) ND (860) ND (2100) ND (3900) ND (3700) ND (8800) ND (420) ND (2200) ND (810) ND (860) ND (2100) ND (3900) ND (3700) ND (8800) ND (420) ND (2200) ND (810) ND (860) ND (2100) ND (3900) ND (3700) ND (8800) ND (420) ND (2200) ND (810) ND (860) ND (2100) ND (3900) ND (3700) ND (8800) ND (420) ND (2200)

7100 8700 16000 35000 31000 76000 1600 16000 ND (810) ND (860) ND (2100) ND (3900) ND (3700) ND (8800) ND (420) ND (2200) ND (810) 900 1700 J 1800 J 1600 J 6100 J 220 J 2500

7,100 9,600 17,700 J 36,800 J 32,600 J 82,100 J 1,820 J 18,500

13968-32-T91.xls

Page 128: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 37 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

268 269 269 270 271 272 273 274S-22-011002-LM-268 S-22-011002-LM-269 S-22-011002-LM-269A S-22-011002-LM-270 S-22-011002-LM-271 S-22-011002-LM-272 S-22-011002-LM-273 S-22-011002-LM-274

1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (92) ND (230) ND (4400) ND (2200) ND (930) ND (420) ND (830) ND (46) ND (92) ND (230) ND (4400) ND (2200) ND (930) ND (420) ND (830) ND (46) ND (92) ND (230) ND (4400) ND (2200) ND (930) ND (420) ND (830) ND (46) ND (92) ND (230) ND (4400) ND (2200) ND (930) ND (420) ND (830)

18 J 910 1000 18000 27000 7800 1700 12000 ND (46) ND (92) ND (230) ND (4400) ND (2200) ND (930) ND (420) ND (830) ND (46) 120 140 J 1700 J 2800 730 J 200 J 1100

18 J 1,030 1,140 J 19,700 J 29,800 8,530 J 1,900 J 13,100

13968-32-T91.xls

Page 129: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 38 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

275 276 277 278 279 280 280 281S-22-011002-LM-275 S-22-011002-LM-276 S-22-011002-LM-277 S-22-011002-LM-278 S-22-011002-LM-279 S-22-011002-LM-280 S-22-011002-LM-280A S-22-011002-LM-281

1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (4800) ND (2300) ND (830) ND (230) ND (43) ND (420) ND (420) ND (22000) ND (4800) ND (2300) ND (830) ND (230) ND (43) ND (420) ND (420) ND (22000) ND (4800) ND (2300) ND (830) ND (230) ND (43) ND (420) ND (420) ND (22000) ND (4800) ND (2300) ND (830) ND (230) ND (43) ND (420) ND (420) ND (22000)

53000 17000 3600 770 450 3600 2300 90000 ND (4800) ND (2300) ND (830) ND (230) ND (43) ND (420) ND (420) ND (22000)

4200 J 1500 J 500 J 110 J 58 380 J 250 J 6300 J

57,200 J 18,500 J 4,100 J 880 J 508 3,980 J 2,550 J 96,300 J

13968-32-T91.xls

Page 130: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 39 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

282 283 284 285 286 286 286 287S-22-011002-LM-282 S-22-011002-LM-283 S-22-011002-LM-284 S-22-011002-LM-285 S-22-011402-LM-286B S-22-011402-LM-286 S-22-011402-LM-286A S-22-011402-LM-287

1/10/2002 1/10/2002 1/10/2002 1/10/2002 1/14/2002 1/14/2002 1/14/2002 1/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-0.67) (0.67-1) (0-0.33)

ND (2200) ND (44) ND (44) ND (46) ND (25000) ND (8500) ND (8600) ND (4500) ND (2200) ND (44) ND (44) ND (46) ND (25000) ND (8500) ND (8600) ND (4500) ND (2200) ND (44) ND (44) ND (46) ND (25000) ND (8500) ND (8600) ND (4500) ND (2200) ND (44) ND (44) ND (46) ND (25000) ND (8500) ND (8600) ND (4500)

11000 ND (44) ND (44) ND (46) 130000 100000 68000 55000 ND (2200) ND (44) ND (44) ND (46) ND (25000) ND (8500) ND (8600) ND (4500)

940 J ND (44) ND (44) ND (46) 11000 J 11000 5200 J 9100

11,940 J 0 0 0 141,000 J 111,000 73,200 J 64,100

13968-32-T91.xls

Page 131: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 40 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

287 287 300 301 302 303 304 305S-22-011402-LM-287A S-22-011402-LM-287B S-00-011702-LM-300 S-00-011702-LM-301 S-00-011702-LM-302 S-00-011702-LM-303 S-00-011702-LM-304 S-00-011702-LM-305

1/14/2002 1/14/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002(0.33-0.67) (0.67-1) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (2100) ND (2100) ND (50) ND (490) ND (22000) ND (44) ND (52) ND (2200) ND (2100) ND (2100) ND (50) ND (490) ND (22000) ND (44) ND (52) ND (2200) ND (2100) ND (2100) ND (50) ND (490) ND (22000) ND (44) ND (52) ND (2200) ND (2100) ND (2100) ND (50) ND (490) ND (22000) ND (44) ND (52) ND (2200)

20000 12000 160 3500 100000 19 J 100 10000 ND (2100) ND (2100) ND (50) ND (490) ND (22000) ND (44) ND (52) ND (2200)

3000 2100 25 J 390 J 7200 J ND (44) 20 J 1000 J

23,000 14,100 185 J 3,890 J 107,200 J 19 J 120 J 11,000 J

13968-32-T91.xls

Page 132: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 41 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

306 307 308 308 308 309 309 310S-00-011702-LM-306 S-00-011702-LM-307 S-00-011702-LM-308 S-00-011702-LM-308A S-00-011702-LM-308B S-00-011702-LM-309 S-00-011702-LM-309A S-00-011702-LM-310

1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (430) ND (47) ND (44) ND (45) ND (42) ND (45) ND (43) ND (43) ND (430) ND (47) ND (44) ND (45) ND (42) ND (45) ND (43) ND (43) ND (430) ND (47) ND (44) ND (45) ND (42) ND (45) ND (43) ND (43) ND (430) ND (47) ND (44) ND (45) ND (42) ND (45) ND (43) ND (43)

2400 ND (47) ND (44) 48 ND (42) 130 46 88 ND (430) ND (47) ND (44) ND (45) ND (42) ND (45) ND (43) ND (43)

300 J ND (47) ND (44) 15 J ND (42) 49 ND (43) 23 J

2,700 J 0 0 63 J 0 179 46 111 J

13968-32-T91.xls

Page 133: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 42 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

310 311 311 312 313 314 315 316 317S-00-011702-LM-310A S-00-011702-LM-311 S-00-011702-LM-311A S-00-011702-LM-312 S-00-011702-LM-313 S-00-011702-LM-314 S-00-011702-LM-315 S-00-011702-LM-316 S-00-011702-LM-317

1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (43) ND (44) ND (44) ND (45) ND (44) ND (21000) ND (1800) ND (45) ND (830) ND (43) ND (44) ND (44) ND (45) ND (44) ND (21000) ND (1800) ND (45) ND (830) ND (43) ND (44) ND (44) ND (45) ND (44) ND (21000) ND (1800) ND (45) ND (830) ND (43) ND (44) ND (44) ND (45) ND (44) ND (21000) ND (1800) ND (45) ND (830)

82 ND (44) 39 J 22 J 38 J 100000 9300 17 J 4000 ND (43) ND (44) ND (44) ND (45) ND (44) ND (21000) ND (1800) ND (45) ND (830)

18 J ND (44) 12 J ND (45) 13 J 6200 J 760 J ND (45) 430 J

100 J 0 51 J 22 J 51 J 106,200 J 10,060 J 17 J 4,430 J

13968-32-T91.xls

Page 134: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 43 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

318 319 319 320 321 322 323 324 325S-00-011702-LM-318 S-00-011702-LM-319 S-00-011702-LM-319A S-00-011702-LM-320 S-00-011702-LM-321 S-00-011702-LM-322 S-00-011702-LM-323 S-00-011702-LM-324 S-00-011702-LM-325

1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (230) ND (47) ND (44) ND (47) ND (220) ND (21000) ND (44) ND (91) ND (44) ND (230) ND (47) ND (44) ND (47) ND (220) ND (21000) ND (44) ND (91) ND (44) ND (230) ND (47) ND (44) ND (47) ND (220) ND (21000) ND (44) ND (91) ND (44) ND (230) ND (47) ND (44) ND (47) ND (220) ND (21000) ND (44) ND (91) ND (44)

620 64 49 36 J 1300 240000 9.5 J 580 15 JND (230) ND (47) ND (44) ND (47) ND (220) ND (21000) ND (44) ND (91) ND (44)

110 J 20 J 15 J ND (47) 200 J 14000 J ND (44) 84 J ND (44)

730 J 84 J 64 J 36 J 1,500 J 254,000 J 9.5 J 664 J 15 J

13968-32-T91.xls

Page 135: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 44 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

326 327 328 328 329 329 330 330S-00-011702-LM-326 S-00-011702-LM-327 S-00-011802-SV-328 S-00-011802-SV-328A S-00-011802-SV-329 S-00-011802-SV-329A S-00-011802-SV-330 S-00-011802-SV-330A

1/17/2002 1/17/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (4900) ND (43) ND (48) ND (42) ND (1100) ND (43) ND (840) ND (410) ND (4900) ND (43) ND (48) ND (42) ND (1100) ND (43) ND (840) ND (410) ND (4900) ND (43) ND (48) ND (42) ND (1100) ND (43) ND (840) ND (410) ND (4900) ND (43) ND (48) ND (42) ND (1100) ND (43) ND (840) ND (410)

43000 33 J ND (48) ND (42) 18000 970 12000 7600 ND (4900) ND (43) ND (48) ND (42) ND (1100) ND (43) ND (840) ND (410)

3000 J 11 J ND (48) ND (42) ND (1100) ND (43) ND (840) ND (410)

46,000 J 44 J 0 0 18,000 970 12,000 7,600

13968-32-T91.xls

Page 136: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 45 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

331 331 332 332 333 334 335 336S-00-011802-SV-331 S-00-011802-SV-331A S-00-011802-SV-332 S-00-011802-SV-332A S-00-011802-SV-333 S-00-011802-SV-334 S-00-011802-SV-335 S-00-011802-SV-336

1/18/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002 1/18/2002(0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (57) ND (43) ND (1000) ND (990) ND (4200) ND (45) ND (44) ND (45) ND (57) ND (43) ND (1000) ND (990) ND (4200) ND (45) ND (44) ND (45) ND (57) ND (43) ND (1000) ND (990) ND (4200) ND (45) ND (44) ND (45)

46 J ND (43) ND (1000) ND (990) ND (4200) 840 13 J 18 JND (57) ND (43) 8300 11000 49000 ND (45) ND (44) ND (45) ND (57) ND (43) ND (1000) ND (990) ND (4200) ND (45) ND (44) ND (45) ND (57) ND (43) ND (1000) ND (990) ND (4200) ND (45) ND (44) ND (45)

46 J 0 8,300 11,000 49,000 840 13 J 18 J

13968-32-T91.xls

Page 137: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 46 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

337 338 339 340 340 341 342 343 344S-00-011802-SV-337 S-00-011802-SV-338 S-00-011802-SV-339 S-00-012102-SV-340 S-00-012102-SV-340A S-00-012102-SV-341 S-00-012102-SV-342 S-00-012102-SV-343 S-00-012102-SV-344

1/18/2002 1/18/2002 1/18/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (41) ND (47) ND (43) ND (44) ND (910) ND (2200) ND (50) ND (52) ND (44) ND (41) ND (47) ND (43) ND (44) ND (910) ND (2200) ND (50) ND (52) ND (44) ND (41) ND (47) ND (43) ND (44) ND (910) ND (2200) ND (50) ND (52)

1400 400 64 ND (43) ND (44) ND (910) ND (2200) ND (50) ND (52) ND (44) ND (41) ND (47) ND (43) 190 5300 10000 29 J 35 JND (44) ND (41) ND (47) 50 ND (44) ND (910) ND (2200) ND (50) ND (52) ND (44) ND (41) ND (47) ND (43) ND (44) ND (910) ND (2200) ND (50) ND (52)

1,400 400 64 50 190 5,300 10,000 29 J 35 J

13968-32-T91.xls

Page 138: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 47 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

345 346 347 348 348 349 349 350S-00-012102-SV-345 S-00-012102-SV-346 S-00-012102-SV-347 S-00-012102-SV-348 S-00-012102-SV-348A S-00-012102-SV-349 S-00-012102-SV-349A S-00-012102-SV-350

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (46) ND (45) ND (45) ND (46) ND (46) ND (50) ND (45) ND (47) ND (46) ND (45) ND (45) ND (46) ND (46) ND (50) ND (45) ND (47) ND (46) ND (45) ND (45) ND (46) ND (46) ND (50) ND (45) ND (47) ND (46) ND (45) ND (45) ND (46) ND (46) ND (50) ND (45) ND (47)

340 260 31 J 66 ND (46) ND (50) ND (45) 210 ND (46) ND (45) ND (45) ND (46) ND (46) ND (50) ND (45) ND (47) ND (46) ND (45) ND (45) ND (46) ND (46) ND (50) ND (45) 25 J

340 260 31 J 66 0 0 0 235 J

13968-32-T91.xls

Page 139: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 48 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

350 351 351 352 352 353 354 355S-00-012102-SV-350A S-00-012102-SV-351 S-00-012102-SV-351A S-00-012102-SV-352 S-00-012102-SV-352A S-00-012102-SV-353 S-00-012102-SV-354 S-00-012102-SV-355

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33)

ND (43) ND (41) ND (41) ND (48) ND (43) ND (45) ND (40) ND (9600) ND (43) ND (41) ND (41) ND (48) ND (43) ND (45) ND (40) ND (9600) ND (43) ND (41) ND (41) ND (48) ND (43) ND (45) ND (40) ND (9600) ND (43) ND (41) ND (41) ND (48) ND (43) ND (45) ND (40) ND (9600) ND (43) 270 270 20 J ND (43) ND (45) 18 J 99000 ND (43) ND (41) ND (41) ND (48) ND (43) ND (45) ND (40) ND (9600)

19 J 44 42 ND (48) ND (43) ND (45) ND (40) ND (9600)

19 J 314 312 20 J 0 0 18 J 99,000

13968-32-T91.xls

Page 140: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 49 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

356 357 358 359 360 361 362 362 363S-00-012102-SV-356 S-00-012102-SV-357 S-00-012102-SV-358 S-00-012102-SV-359 S-00-012102-SV-360 S-00-012102-SV-361 S-00-012102-SV-362 S-00-012102-SV-362A S-00-012202-MD-363

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (41) ND (47) ND (48) ND (45) ND (410) ND (47) ND (52) ND (51) ND (42) ND (41) ND (47) ND (48) ND (45) ND (410) ND (47) ND (52) ND (51) ND (42) ND (41) ND (47) ND (48) ND (45) ND (410) ND (47) ND (52) ND (51) ND (42) ND (41) ND (47) ND (48) ND (45) ND (410) ND (47) ND (52) ND (51) ND (42)

280 28 J 16 J 280 7400 220 56 44 J 9.9 JND (41) ND (47) ND (48) ND (45) ND (410) ND (47) ND (52) ND (51) ND (42)

38 J ND (47) ND (48) 73 470 29 J ND (52) ND (51) ND (42)

318 J 28 J 16 J 353 7,870 249 J 56 44 J 9.9 J

13968-32-T91.xls

Page 141: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 50 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

363 364 365 366 367 367 368 369S-00-012202-MD-363A S-00-012202-MD-364 S-00-012202-MD-365 S-00-012202-MD-366 S-00-012302-GS-367 S-00-012302-GS-367A S-00-012302-GS-368 S-00-012302-GS-369

1/22/2002 1/22/2002 1/22/2002 1/22/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (43) ND (870) ND (510) ND (46) ND (48) ND (49) ND (95) ND (480) ND (43) ND (870) ND (510) ND (46) ND (48) ND (49) ND (95) ND (480) ND (43) ND (870) ND (510) ND (46) ND (48) ND (49) ND (95) ND (480) ND (43) ND (870) ND (510) ND (46) ND (48) ND (49) ND (95) ND (480)

52 9200 8100 150 ND (48) ND (49) ND (95) 3000 ND (43) ND (870) ND (510) ND (46) 33 J 56 450 ND (480) ND (43) 810 J 470 J 18 J ND (48) ND (49) ND (95) 420 J

52 10,010 J 8,570 J 168 J 33 J 56 450 3,420 J

13968-32-T91.xls

Page 142: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 51 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

370 371 371 372 372 373 373 373S-00-012302-GS-370 S-00-012302-GS-371 S-00-012302-GS-371A S-00-012302-GS-372 S-00-012302-GS-372A S-00-012302-GS-373 S-00-012302-GS-373A S-00-012302-GS-373B

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0.33-2)

Duplicate

ND (46) ND (47) ND (42) ND (10000) ND (8600) ND (46) ND (2200) ND (2300) ND (46) ND (47) ND (42) ND (10000) ND (8600) ND (46) ND (2200) ND (2300) ND (46) ND (47) ND (42) ND (10000) ND (8600) ND (46) ND (2200) ND (2300) ND (46) ND (47) ND (42) ND (10000) ND (8600) ND (46) ND (2200) ND (2300) ND (46) ND (47) ND (42) 110000 83000 ND (46) 17000 18000

96 ND (47) ND (42) ND (10000) ND (8600) 100 ND (2200) ND (2300) ND (46) ND (47) ND (42) 11000 7400 J ND (46) 1800 J 1900 J

96 0 0 121,000 90,400 J 100 18,800 J 19,900 J

13968-32-T91.xls

Page 143: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 52 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

374 374 375 376 377 378 379 380S-00-012302-CH-374 S-00-012302-CH-374A S-00-012302-GS-375 S-00-012302-GS-376 S-00-012302-GS-377 S-00-012302-GS-378 S-00-012302-GS-379 S-00-012302-GS-380

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0.33-1.5) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (45) ND (43) ND (230) ND (22000) ND (46) ND (45) ND (45) ND (1900) ND (45) ND (43) ND (230) ND (22000) ND (46) ND (45) ND (45) ND (1900) ND (45) ND (43) ND (230) ND (22000) ND (46) ND (45) ND (45) ND (1900) ND (45) ND (43) ND (230) ND (22000) ND (46) ND (45) ND (45) ND (1900) ND (45) ND (43) ND (230) 240000 ND (46) ND (45) ND (45) 13000

33 J ND (43) 520 ND (22000) 290 96 68 ND (1900) ND (45) ND (43) ND (230) 24000 ND (46) ND (45) ND (45) 1700 J

33 J 0 520 264,000 290 96 68 14,700 J

13968-32-T91.xls

Page 144: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 53 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

381 382 382 383 384 385 386 387S-00-012302-GS-381 S-00-012302-GS-382 S-00-012302-GS-382A S-00-012302-CH-383 S-00-012302-CH-384 S-00-012302-GS-385 S-00-012302-GS-386 S-00-012302-GS-387

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (4700) ND (47) ND (4700) ND (48) ND (960) ND (1000) ND (47) ND (43) ND (4700) ND (47) ND (4700) ND (48) ND (960) ND (1000) ND (47) ND (43) ND (4700) ND (47) ND (4700) ND (48) ND (960) ND (1000) ND (47) ND (43) ND (4700) ND (47) ND (4700) ND (48) ND (960) ND (1000) ND (47) ND (43)

58000 ND (47) 39000 ND (48) 12000 12000 ND (47) ND (43) ND (4700) 78 ND (4700) 210 ND (960) ND (1000) 120 110

6900 ND (47) 4100 J ND (48) 1500 1500 ND (47) ND (43)

64,900 78 43,100 J 210 13,500 13,500 120 110

13968-32-T91.xls

Page 145: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 54 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

388 389 390 390 391 391 392 392S-00-012302-GS-388 S-00-012302-GS-389 S-00-012302-CH-390 S-00-012302-CH-390A S-00-012302-CH-391 S-00-012302-CH-391A S-00-012302-GS-392 S-00-012302-GS-392A

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-1) (0-0.33) (0.33-1.33)

Duplicate

ND (4700) ND (8700) ND (47) ND (48) ND (48) ND (44) ND (4300) ND (410) ND (4700) ND (8700) ND (47) ND (48) ND (48) ND (44) ND (4300) ND (410) ND (4700) ND (8700) ND (47) ND (48) ND (48) ND (44) ND (4300) ND (410) ND (4700) ND (8700) ND (47) ND (48) ND (48) ND (44) ND (4300) ND (410)

30000 71000 ND (47) 150 ND (48) ND (44) 19000 2700 ND (4700) ND (8700) 130 ND (48) 290 ND (44) ND (4300) ND (410)

2900 J 7500 J ND (47) 41 J ND (48) ND (44) 2800 J 370 J

32,900 J 78,500 J 130 191 J 290 0 21,800 J 3,070 J

13968-32-T91.xls

Page 146: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 55 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

393 393 394 394 395 396 397 398S-00-012302-CH-393 S-00-012302-CH-393A S-00-012302-GS-394 S-00-012302-GS-394A S-00-012302-GS-395 S-00-012302-GS-396 S-00-012302-CH-397 S-00-012302-CH-398

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0.33-1) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (4700) ND (420) ND (47) ND (43) ND (2300) ND (2200) ND (47) ND (44) ND (4700) ND (420) ND (47) ND (43) ND (2300) ND (2200) ND (47) ND (44) ND (4700) ND (420) ND (47) ND (43) ND (2300) ND (2200) ND (47) ND (44) ND (4700) ND (420) ND (47) ND (43) ND (2300) ND (2200) ND (47) ND (44)

26000 4000 ND (47) ND (43) 17000 17000 ND (47) ND (44) ND (4700) ND (420) 160 ND (43) ND (2300) ND (2200) 210 87

3300 J 450 ND (47) ND (43) 2500 2100 J ND (47) ND (44)

29,300 J 4,450 160 0 19,500 19,100 J 210 87

13968-32-T91.xls

Page 147: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 56 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

399 400 401 402 403 404 404 405S-00-012302-CH-399 S-00-012302-CH-400 S-00-012302-GS-401 S-00-012302-GS-402 S-00-012302-CH-403 S-00-012302-GS-404 S-00-012302-GS-404A S-00-012302-CH-405

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (47) ND (430) ND (740) ND (4000) ND (42) ND (44) ND (43) ND (4600) ND (47) ND (430) ND (740) ND (4000) ND (42) ND (44) ND (43) ND (4600) ND (47) ND (430) ND (740) ND (4000) ND (42) ND (44) ND (43) ND (4600) ND (47) ND (430) ND (740) ND (4000) ND (42) ND (44) ND (43) ND (4600) ND (47) 4300 7400 28000 300 ND (44) ND (43) 35000

81 ND (430) ND (740) ND (4000) ND (42) 260 100 ND (4600) ND (47) 710 770 6300 49 ND (44) ND (43) 4300

81 5,010 8,170 34,300 349 260 100 39,300

13968-32-T91.xls

Page 148: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 57 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

406 407 407 408 409 410 411 411S-00-012302-CH-406 S-00-012302-GS-407 S-00-012302-GS-407A S-00-012302-CH-408 S-00-012302-GS-409 S-00-012302-GS-410 S-00-012402-GS-411 S-00-012402-GS-411A

1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/23/2002 1/24/2002 1/24/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2)

Duplicate

ND (47) ND (51) ND (47) ND (40) ND (2300) ND (52) ND (51) ND (42) ND (47) ND (51) ND (47) ND (40) ND (2300) ND (52) ND (51) ND (42) ND (47) ND (51) ND (47) ND (40) ND (2300) ND (52) ND (51) ND (42) ND (47) ND (51) ND (47) ND (40) ND (2300) ND (52) ND (51) ND (42) ND (47) ND (51) ND (47) ND (40) 12000 ND (52) 340 ND (42)

44 53 80 210 ND (2300) 140 ND (51) ND (42) ND (47) ND (51) ND (47) ND (40) 3000 ND (52) 75 13 J

44 53 80 210 15,000 140 415 13 J

13968-32-T91.xls

Page 149: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 58 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

411 412 412 413 413 414 414 415S-00-012402-GS-411B S-00-012402-GS-412 S-00-012402-CH-412A S-00-012402-GS-413 S-00-012402-GS-413A S-00-012402-GS-414 S-00-012402-GS-414A S-00-012402-GS-415

1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002(0.33-2) (0-0.33) (0.33-0.5) (0-0.33) (0.33-0.5) (0-0.33) (0.33-0.5) (0-0.33)

Duplicate

ND (44) ND (2000) ND (2100) ND (4300) ND (8500) ND (250) ND (240) ND (49) ND (44) ND (2000) ND (2100) ND (4300) ND (8500) ND (250) ND (240) ND (49) ND (44) ND (2000) ND (2100) ND (4300) ND (8500) ND (250) ND (240) ND (49) ND (44) ND (2000) ND (2100) ND (4300) ND (8500) ND (250) ND (240) ND (49) ND (44) 17000 22000 59000 130000 980 860 140 ND (44) ND (2000) ND (2100) ND (4300) ND (8500) ND (250) ND (240) ND (49) ND (44) 1400 J 1700 J 8400 15000 280 280 ND (49)

0 18,400 J 23,700 J 67,400 145,000 1,260 1,140 140

13968-32-T91.xls

Page 150: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 59 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

416 417 418 418 419 420 421 422S-00-012402-GS-416 S-00-012402-GS-417 S-00-012402-GS-418 S-00-012402-GS-418A S-00-012402-GS-419 S-00-012402-GS-420 S-00-012402-CH-421 S-00-012402-CH-422

1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (270) ND (4400) ND (480) ND (470) ND (49) ND (450) ND (2200) ND (51) ND (270) ND (4400) ND (480) ND (470) ND (49) ND (450) ND (2200) ND (51) ND (270) ND (4400) ND (480) ND (470) ND (49) ND (450) ND (2200) ND (51) ND (270) ND (4400) ND (480) ND (470) ND (49) ND (450) ND (2200) ND (51)

1600 41000 3700 4700 ND (49) 6700 26000 340 ND (270) ND (4400) ND (480) ND (470) ND (49) ND (450) ND (2200) ND (51)

240 J 3500 J 380 J 600 17 J 530 1800 J 40 J

1,840 J 44,500 J 4,080 J 5,300 17 J 7,230 27,800 J 380 J

13968-32-T91.xls

Page 151: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 60 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

423 424 425S-00-012402-CH-423 S-00-012402-CH-424 S-00-012402-CH-425

1/24/2002 1/24/2002 1/24/2002(0-0.33) (0-0.33) (0-0.33)

ND (48) ND (810) ND (960) ND (48) ND (810) ND (960) ND (48) ND (810) ND (960) ND (48) ND (810) ND (960)

300 8600 9900 ND (48) ND (810) ND (960)

43 J 670 J 1000

343 J 9,270 J 10,900

13968-32-T91.xls

Page 152: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 61 of 314

Sample Location: 426 427 428 429 429 430 431 431Sample ID: S-00-012402-CH-426 S-00-012402-GS-427 S-00-012402-GS-428 S-00-012402-GS-429 S-00-012402-GS-429A S-00-012402-GS-430 S-00-012402-GS-431 S-00-012402-GS-431ASample Date: 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002Sample Depth: (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (51) ND (970) ND (900) ND (48) ND (47) ND (47) ND (49) ND (44) Aroclor-1221 (PCB-1221) ug/Kg ND (51) ND (970) ND (900) ND (48) ND (47) ND (47) ND (49) ND (44) Aroclor-1232 (PCB-1232) ug/Kg ND (51) ND (970) ND (900) ND (48) ND (47) ND (47) ND (49) ND (44) Aroclor-1242 (PCB-1242) ug/Kg ND (51) ND (970) ND (900) ND (48) ND (47) ND (47) ND (49) ND (44) Aroclor-1248 (PCB-1248) ug/Kg 34 J 5900 7200 57 27 J ND (47) 90 27 JAroclor-1254 (PCB-1254) ug/Kg ND (51) ND (970) ND (900) ND (48) ND (47) ND (47) ND (49) ND (44) Aroclor-1260 (PCB-1260) ug/Kg ND (51) 740 J 790 J ND (48) ND (47) ND (47) ND (49) ND (44)

Sum of Detected PCBs (ND=0) ug/Kg 34 J 6,640 J 7,990 J 57 27 J 0 90 27 J

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 153: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 62 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

432 432 433 433 434 434 435 436S-00-012402-GS-432 S-00-012402-GS-432A S-00-012402-CH-433 S-00-012402-CH-433A S-00-012402-CH-434 S-00-012402-GS-434A S-00-012402-GS-435 S-00-012402-GS-436

1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002(0-0.33) (0.33-1) (0-0.33) (0.33-1.25) (0-0.33) (0.33-0.58) (0-0.33) (0-0.33)

ND (890) ND (210) ND (1000) ND (9400) ND (100) ND (93) ND (45) ND (46) ND (890) ND (210) ND (1000) ND (9400) ND (100) ND (93) ND (45) ND (46) ND (890) ND (210) ND (1000) ND (9400) ND (100) ND (93) ND (45) ND (46) ND (890) ND (210) ND (1000) ND (9400) ND (100) ND (93) ND (45) ND (46)

5900 820 11000 160000 570 580 ND (45) 40 JND (890) ND (210) ND (1000) ND (9400) ND (100) ND (93) ND (45) ND (46)

800 J ND (210) 1300 11000 ND (100) 68 J ND (45) ND (46)

6,700 J 820 12,300 171,000 570 648 J 0 40 J

13968-32-T91.xls

Page 154: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 63 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

437 438 438 439 439 440 440 441S-00-012402-GS-437 S-00-012402-CH-438 S-00-012402-CH-438A S-00-012802-CH-439 S-00-012802-CH-439A S-00-012502-CH-440 S-00-012502-CH-440A S-00-012502-GS-441

1/24/2002 1/24/2002 1/24/2002 1/28/2002 1/28/2002 1/25/2002 1/25/2002 1/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate Duplicate

ND (2200) ND (4500) ND (2100) ND (39) ND (39) ND (440) ND (420) ND (840) ND (2200) ND (4500) ND (2100) ND (39) ND (39) ND (440) ND (420) ND (840) ND (2200) ND (4500) ND (2100) ND (39) ND (39) ND (440) ND (420) ND (840) ND (2200) ND (4500) ND (2100) 26 J 24 J ND (440) ND (420) ND (840)

17000 28000 22000 ND (39) ND (39) ND (440) ND (420) ND (840) ND (2200) ND (4500) ND (2100) 17 J 15 J 2500 2900 5300 ND (2200) 3000 J 2300 ND (39) ND (39) ND (440) ND (420) ND (840)

17,000 31,000 J 24,300 43 J 39 J 2,500 2,900 5,300

13968-32-T91.xls

Page 155: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 64 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

442 443 444 444 445 445 446 446S-00-012502-GS-442 S-00-012502-GS-443 S-00-012802-CH-444 S-00-012802-CH-444A S-00-012502-CH-445 S-00-012502-CH-445A S-00-012502-GS-446 S-00-012502-GS-446A

1/25/2002 1/25/2002 1/28/2002 1/28/2002 1/25/2002 1/25/2002 1/25/2002 1/25/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) ND (95) ND (41) ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) ND (95) ND (41) ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) ND (95) ND (41) ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) ND (95) ND (41) ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) ND (95) ND (41) ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) 360 100 ND (42) ND (44) ND (45) ND (41) ND (44) ND (42) ND (95) ND (41)

0 0 0 0 0 0 360 100

13968-32-T91.xls

Page 156: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 65 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

447 447 448 448 448 449 450 451S-00-012502-GS-447 S-00-012502-GS-447A S-00-012502-GS-448 S-00-012502-GS-448A S-00-012502-GS-448B S-00-012802-CH-449 S-00-012502-CH-450 S-00-012502-GS-451

1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/28/2002 1/25/2002 1/25/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0.33-2) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (41) ND (48) ND (48) ND (44) ND (45) ND (44) ND (43) ND (45) ND (41) ND (48) ND (48) ND (44) ND (45) ND (44) ND (43) ND (45) ND (41) ND (48) ND (48) ND (44) ND (45) ND (44) ND (43) ND (45) ND (41) ND (48) ND (48) ND (44) ND (45) 9.7 J ND (43) ND (45) ND (41) ND (48) ND (48) ND (44) ND (45) ND (44) ND (43) ND (45) ND (41) ND (48) ND (48) ND (44) ND (45) ND (44) 42 J 64 ND (41) ND (48) ND (48) ND (44) ND (45) ND (44) ND (43) ND (45)

0 0 0 0 0 9.7 J 42 J 64

13968-32-T91.xls

Page 157: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 66 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

452 453 454 455 455 456 457 458 459S-00-012502-GS-452 S-00-012502-GS-453 S-00-012802-CH-454 S-00-012502-CH-455 S-00-012502-CH-455A S-00-012502-GS-456 S-00-012502-GS-457 S-00-012502-GS-458 S-00-012802-CH-459

1/25/2002 1/25/2002 1/28/2002 1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (42) ND (44) ND (41) ND (47) ND (46) ND (97) ND (45) ND (52) ND (48) ND (42) ND (44) ND (41) ND (47) ND (46) ND (97) ND (45) ND (52) ND (48) ND (42) ND (44) ND (41) ND (47) ND (46) ND (97) ND (45) ND (52) ND (48) ND (42) ND (44) ND (41) ND (47) ND (46) ND (97) ND (45) ND (52) 25 JND (42) ND (44) ND (41) ND (47) ND (46) ND (97) ND (45) ND (52) ND (48) ND (42) ND (44) ND (41) 37 J 65 1100 ND (45) ND (52) 8.2 JND (42) ND (44) ND (41) ND (47) ND (46) ND (97) ND (45) ND (52) ND (48)

0 0 0 37 J 65 1,100 0 0 33.2 J

13968-32-T91.xls

Page 158: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 67 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

460 461 462 463 464 465 465 466S-00-012502-CH-460 S-00-012502-CH-461 S-00-012502-GS-462 S-00-012502-GS-463 S-00-012802-CH-464 S-00-012502-CH-465 S-00-012502-CH-465A S-00-012502-GS-466

1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/28/2002 1/25/2002 1/25/2002 1/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (43) ND (44) ND (220) ND (44) ND (46) ND (46) ND (45) ND (43) ND (43) ND (44) ND (220) ND (44) ND (46) ND (46) ND (45) ND (43) ND (43) ND (44) ND (220) ND (44) ND (46) ND (46) ND (45) ND (43) ND (43) ND (44) ND (220) ND (44) 19 J ND (46) ND (45) ND (43) ND (43) ND (44) 540 ND (44) ND (46) ND (46) ND (45) ND (43) ND (43) ND (44) ND (220) ND (44) 8.2 J 270 300 26 JND (43) ND (44) 190 J ND (44) ND (46) ND (46) ND (45) ND (43)

0 0 730 J 0 27.2 J 270 300 26 J

13968-32-T91.xls

Page 159: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 68 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

467 468 469 469 470 470 471 471S-00-012502-GS-467 S-00-012502-GS-468 S-00-012802-CH-469 S-00-012802-CH-469A S-00-012502-CH-470A S-00-012502-CH-470 S-00-012502-CH-471 S-00-012502-CH-471A

1/25/2002 1/25/2002 1/28/2002 1/28/2002 1/25/2002 1/25/2002 1/25/2002 1/25/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (47) ND (46) ND (50) ND (44) ND (40) ND (44) ND (4900) ND (400) ND (47) ND (46) ND (50) ND (44) ND (40) ND (44) ND (4900) ND (400) ND (47) ND (46) ND (50) ND (44) ND (40) ND (44) ND (4900) ND (400) ND (47) ND (46) ND (50) ND (44) ND (40) ND (44) ND (4900) ND (400) ND (47) ND (46) 27 J ND (44) ND (40) ND (44) 42000 4100 ND (47) ND (46) ND (50) ND (44) ND (40) 48 ND (4900) ND (400) ND (47) ND (46) 15 J ND (44) ND (40) ND (44) 11000 1000

0 0 42 J 0 0 48 53,000 5,100

13968-32-T91.xls

Page 160: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 69 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

472 472 473 473 474 474 475 475S-00-012502-GS-472 S-00-012502-GS-472A S-00-012502-CH-473 S-00-012502-CH-473A S-00-012802-CH-474 S-00-012802-CH-474A S-00-012502-GS-475 S-00-012802-CH-475

1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/28/2002 1/28/2002 1/25/2002 1/28/2002(0-0.33) (0.33-1.5) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (44) ND (44) ND (45) ND (44) ND (44) ND (220) ND (44) ND (48) ND (44) ND (44) ND (45) ND (44) ND (44) ND (220) ND (44) ND (48) ND (44) ND (44) ND (45) ND (44) ND (44) ND (220) ND (44) ND (48) ND (44) ND (44) ND (45) ND (44) ND (44) ND (220) ND (44) ND (48) ND (44) ND (44) ND (45) 28 J 31 J ND (220) 36 J

310 150 37 J ND (45) ND (44) ND (44) ND (220) ND (44) ND (48) ND (44) ND (44) ND (45) 11 J ND (44) 51 J 16 J

310 150 37 J 0 39 J 31 J 51 J 52 J

13968-32-T91.xls

Page 161: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 70 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

476 476 477 478 479 480 481 482S-00-012502-GS-476 S-00-012502-GS-476A S-00-012502-MD-477 S-00-012802-CH-478 S-00-012502-MD-479 S-00-012502-GS-480 S-00-012502-MD-481 S-00-012802-CH-482

1/25/2002 1/25/2002 1/25/2002 1/28/2002 1/25/2002 1/25/2002 1/25/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (220) ND (460) ND (44) ND (47) ND (3900) ND (4100) ND (46) ND (45) ND (220) ND (460) ND (44) ND (47) ND (3900) ND (4100) ND (46) ND (45) ND (220) ND (460) ND (44) ND (47) ND (3900) ND (4100) ND (46) ND (45) ND (220) ND (460) ND (44) ND (47) ND (3900) ND (4100) ND (46) ND (45) ND (220) ND (460) ND (44) 180 22000 12000 ND (46) 72

810 1600 ND (44) ND (47) ND (3900) ND (4100) ND (46) ND (45) ND (220) ND (460) ND (44) 88 5300 4000 J ND (46) 32 J

810 1,600 0 268 27,300 16,000 J 0 104 J

13968-32-T91.xls

Page 162: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 71 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

483 483 484 485 487 488 488 489S-00-012502-GS-483 S-00-012502-MD-483A S-00-012502-GS-484 S-00-012502-GS-485 S-00-012802-LM-487 S-00-012802-LM-488 S-00-012802-LM-488A S-00-012802-JK-489

1/25/2002 1/25/2002 1/25/2002 1/25/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (4400) ND (4500) ND (4400) ND (45) ND (54) ND (49) ND (47) ND (43) ND (4400) ND (4500) ND (4400) ND (45) ND (54) ND (49) ND (47) ND (43) ND (4400) ND (4500) ND (4400) ND (45) ND (54) ND (49) ND (47) ND (43) ND (4400) ND (4500) ND (4400) ND (45) 9.7 J 21 J 20 J ND (43)

25000 21000 24000 ND (45) ND (54) ND (49) ND (47) 1300 ND (4400) ND (4500) ND (4400) 79 ND (54) ND (49) ND (47) ND (43)

5200 5200 7400 ND (45) ND (54) ND (49) ND (47) 120

30,200 26,200 31,400 79 9.7 J 21 J 20 J 1,420

13968-32-T91.xls

Page 163: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 72 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

490 491 492 493 494 495 495 496S-00-012802-LM-490 S-00-012802-LM-491 S-00-012802-JK-492 S-00-012802-JK-493 S-00-012802-JK-494 S-00-012802-LM-495 S-00-012802-LM-495A S-00-012802-LM-496

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.167) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (880) ND (48) ND (52) ND (49) ND (42) ND (200) ND (800) ND (47) ND (880) ND (48) ND (52) ND (49) ND (42) ND (200) ND (800) ND (47) ND (880) ND (48) ND (52) ND (49) ND (42) ND (200) ND (800) ND (47) ND (880) 1500 6 J ND (49) 19 J ND (200) ND (800) 160

18000 ND (48) ND (52) ND (49) ND (42) 4600 13000 ND (47) ND (880) ND (48) ND (52) ND (49) ND (42) ND (200) ND (800) ND (47)

1900 ND (48) ND (52) ND (49) ND (42) 420 760 J ND (47)

19,900 1,500 6 J 0 19 J 5,020 13,760 J 160

13968-32-T91.xls

Page 164: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 73 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

497 498 499 500 501 501 502 502S-00-012802-JK-497 S-00-012802-JK-498 S-00-012802-LM-499 S-00-012802-LM-500 S-00-012802-GS-501 S-00-012802-GS-501A S-00-012802-GS-502 S-00-012802-GS-502A

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-0.667) (0-0.33) (0.33-2)

ND (46) ND (47) ND (48) ND (840) ND (51) ND (47) ND (47) ND (42) ND (46) ND (47) ND (48) ND (840) ND (51) ND (47) ND (47) ND (42) ND (46) ND (47) ND (48) ND (840) ND (51) ND (47) ND (47) ND (42) ND (46) ND (47) 8.5 J ND (840) 9.5 J ND (47) 7.8 J ND (42) ND (46) ND (47) ND (48) 12000 ND (51) ND (47) ND (47) ND (42) ND (46) ND (47) ND (48) ND (840) ND (51) ND (47) ND (47) ND (42) ND (46) ND (47) ND (48) 920 ND (51) ND (47) ND (47) ND (42)

0 0 8.5 J 12,920 9.5 J 0 7.8 J 0

13968-32-T91.xls

Page 165: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 74 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

503 503 504 504 504 505 505 506S-00-012802-GS-503 S-00-012802-GS-503A S-00-012802-CH-504 S-00-012802-CH-504A S-00-012802-CH-504B S-00-012802-CH-505 S-00-012802-CH-505A S-00-012802-GS-506

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0.33-1.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-0.5) (0-0.33)

Duplicate

ND (46) ND (44) ND (46) ND (46) ND (41) ND (48) ND (44) ND (50) ND (46) ND (44) ND (46) ND (46) ND (41) ND (48) ND (44) ND (50) ND (46) ND (44) ND (46) ND (46) ND (41) ND (48) ND (44) ND (50) ND (46) 63 1200 1000 350 13 J 7.3 J 8.2 J

190 ND (44) ND (46) ND (46) ND (41) ND (48) ND (44) ND (50) ND (46) ND (44) ND (46) ND (46) ND (41) ND (48) ND (44) ND (50)

30 J ND (44) ND (46) ND (46) ND (41) ND (48) ND (44) ND (50)

220 J 63 1,200 1,000 350 13 J 7.3 J 8.2 J

13968-32-T91.xls

Page 166: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 75 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

507 508 509 509 510 511 512 513 514S-00-012802-GS-507 S-00-012802-GS-508 S-00-012802-GS-509 S-00-012802-GS-509A S-00-012802-GS-510 S-00-012802-GS-511 S-00-012802-GS-512 S-00-012802-GS-513 S-00-012802-GS-514

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (450) ND (4300) ND (880) ND (860) ND (47) ND (47) ND (880) ND (820) ND (2500) ND (450) ND (4300) ND (880) ND (860) ND (47) ND (47) ND (880) ND (820) ND (2500) ND (450) ND (4300) ND (880) ND (860) ND (47) ND (47) ND (880) ND (820) ND (2500) ND (450) ND (4300) ND (880) ND (860) 18 J 14 J ND (880) ND (820) ND (2500)

8800 62000 24000 25000 ND (47) ND (47) 18000 12000 53000 ND (450) ND (4300) ND (880) ND (860) ND (47) ND (47) ND (880) ND (820) ND (2500)

630 4000 J 1600 1800 ND (47) ND (47) 1300 970 3100

9,430 66,000 J 25,600 26,800 18 J 14 J 19,300 12,970 56,100

13968-32-T91.xls

Page 167: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 76 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

515 516 517 518 519 519 520 521 522S-00-012802-GS-515 S-00-012802-CH-516 S-00-012802-CH-517 S-00-012802-CH-518 S-00-012802-GS-519 S-00-012802-GS-519A S-00-012802-GS-520 S-00-012802-GS-521 S-00-012802-CH-522

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (8000) ND (44) ND (46) ND (47) ND (48) ND (860) ND (870) ND (850) ND (46) ND (8000) ND (44) ND (46) ND (47) ND (48) ND (860) ND (870) ND (850) ND (46) ND (8000) ND (44) ND (46) ND (47) ND (48) ND (860) ND (870) ND (850) ND (46) ND (8000) ND (44) ND (46) ND (47) ND (48) ND (860) 11000 ND (850) ND (46) 74000 25 J 29 J 99 94 8900 ND (870) 12000 ND (46) ND (8000) ND (44) ND (46) ND (47) ND (48) ND (860) ND (870) ND (850) ND (46) 7700 J ND (44) ND (46) ND (47) ND (48) 750 J 1100 1000

0 81,700 J 25 J 29 J 99 94 9,650 J 12,100 13,000

13968-32-T91.xls

Page 168: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 77 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

523 524 524 524 525 525 526 526S-00-012802-GS-523 S-00-012802-JW-524 S-00-012802-JW-524A S-00-012802-JW-524B S-00-012802-JW-525 S-00-012802-JW-525A S-00-012802-GS-526 S-00-012802-GS-526A

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-0.667) (0-0.33) (0.33-2)

Duplicate

ND (48) ND (45) ND (44) ND (43) ND (22000) ND (2000) ND (2100) ND (80) ND (48) ND (45) ND (44) ND (43) ND (22000) ND (2000) ND (2100) ND (80) ND (48) ND (45) ND (44) ND (43) ND (22000) ND (2000) ND (2100) ND (80)

8.2 J 8.6 J 9.4 J ND (43) ND (22000) ND (2000) ND (2100) ND (80) ND (48) ND (45) ND (44) ND (43) 200000 32000 26000 2400 ND (48) ND (45) ND (44) ND (43) ND (22000) ND (2000) ND (2100) ND (80) ND (48) ND (45) ND (44) ND (43) 16000 J 3400 3900 400

8.2 J 8.6 J 9.4 J 0 216,000 J 35,400 29,900 2,800

13968-32-T91.xls

Page 169: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 78 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

527 527 528 528 529 529 530 530S-00-012802-CH-527 S-00-012802-CH-527A S-00-012802-CH-528 S-00-012802-CH-528A S-00-012802-GS-529 S-00-012802-GS-529A S-00-012802-JW-530 S-00-012802-JW-530A

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002(0-0.33) (0.33-0.833) (0-0.33) (0-0.33) (0-0.33) (0.33-0.5) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (800) ND (390) ND (2100) ND (2100) ND (49) ND (48) ND (49) ND (49) ND (800) ND (390) ND (2100) ND (2100) ND (49) ND (48) ND (49) ND (49) ND (800) ND (390) ND (2100) ND (2100) ND (49) ND (48) ND (49) ND (49)

6500 ND (390) ND (2100) ND (2100) 12 J 15 J ND (49) ND (49) ND (800) 6000 28000 29000 ND (49) ND (48) 32 J 24 JND (800) ND (390) ND (2100) ND (2100) ND (49) ND (48) ND (49) ND (49) ND (800) 710 3300 3500 ND (49) ND (48) 18 J 18 J

6,500 6,710 31,300 32,500 12 J 15 J 50 J 42 J

13968-32-T91.xls

Page 170: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 79 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

531 532 533 534 534 539 540 543S-00-012802-JW-531 S-00-012802-JW-532 S-00-012802-JW-533 S-00-012802-JW-534 S-00-012802-JW-534A S-00-012902-TR-539 S-00-012902-TR-540 S-00-012902-TR-543

1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/28/2002 1/29/2002 1/29/2002 1/29/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (46) ND (43) ND (830) ND (850) ND (51) ND (44) ND (47) ND (44) ND (46) ND (43) ND (830) ND (850) ND (51) ND (44) ND (47) ND (44) ND (46) ND (43) ND (830) ND (850) ND (51) ND (44) ND (47) ND (44) ND (46) 120 ND (830) ND (850) ND (51) ND (44) ND (47)

23 J 33 J ND (43) 15000 11000 ND (51) ND (44) ND (47) ND (44) ND (46) ND (43) ND (830) ND (850) ND (51) ND (44) ND (47) ND (44) 16 J 46 1300 1100 ND (51) ND (44) ND (47)

23 J 49 J 166 16,300 12,100 0 0 0

13968-32-T91.xls

Page 171: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 80 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

544 545 545 546 548 549 549 552S-00-012902-GS-544 S-00-012902-GS-545 S-00-012902-GS-545A S-00-012902-GS-546 S-00-012902-GS-548 S-00-012902-GS-549 S-00-012902-GS-549A S-00-012902-LM-552

1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/29/2002 1/29/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45) ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45) ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45) ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45) ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45) ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45) ND (45) ND (41) ND (43) ND (45) ND (48) ND (43) ND (43) ND (45)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 172: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 81 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

553 554 555 558 558 559 562 563S-00-012902-LM-553 S-00-013002-GS-554 S-00-013002-GS-555 S-00-013002-GS-558 S-00-013002-GS-558A S-00-013002-GS-559 S-00-013002-GS-562 S-00-013002-GS-563

1/29/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (47) ND (48) ND (45) ND (44) ND (46) ND (46) ND (40) ND (46) ND (47) ND (48) ND (45) ND (44) ND (46) ND (46) ND (40) ND (46) ND (47) ND (48) ND (45) ND (44) ND (46) ND (46) ND (40) ND (46) ND (47) ND (48) ND (45) ND (44) ND (46) ND (46) ND (40) ND (46) ND (47) ND (48) ND (45) ND (44) ND (46) 94 27 JND (46) ND (47) ND (48) ND (45) ND (44) ND (46) ND (46) ND (40) ND (46) ND (47) ND (48) ND (45) ND (44) ND (46) 32 J ND (40)

0 0 0 0 0 0 126 J 27 J

13968-32-T91.xls

Page 173: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 82 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

566 566 567 568 569 570 571 572 573S-00-013002-GS-566 S-00-013002-GS-566A S-00-013002-JK-567 S-00-013002-GS-568 S-00-013002-CH-569 S-00-013002-JK-570 S-00-013002-JH-571 S-00-013002-GS-572 S-00-013002-GS-573

1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (910) ND (450) ND (2200) ND (49) ND (5200) ND (4900) ND (5000) ND (4700) ND (460) ND (910) ND (450) ND (2200) ND (49) ND (5200) ND (4900) ND (5000) ND (4700) ND (460) ND (910) ND (450) ND (2200) ND (49) ND (5200) ND (4900) ND (5000) ND (4700) ND (460) ND (910) ND (450) ND (2200) ND (49) ND (5200) ND (4900) ND (5000) ND (4700) ND (460)

3700 3200 9200 240 32000 32000 46000 24000 2000 ND (910) ND (450) ND (2200) ND (49) ND (5200) ND (4900) ND (5000) ND (4700) ND (460)

600 J 540 1300 J 53 4000 J 3700 J 5200 3300 J 780

4,300 J 3,740 10,500 J 293 36,000 J 35,700 J 51,200 27,300 J 2,780

13968-32-T91.xls

Page 174: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 83 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

574 575 575 576 576 577 577 577S-00-013002-JK-574 S-00-013002-GS-575 S-00-013002-GS-575A S-00-013002-GS-576 S-00-013002-GS-576A S-00-013002-GS-577 S-00-013002-GS-577B S-00-013002-GS-577A

1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002(0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2)

Duplicate

ND (50) ND (45) ND (45) ND (460) ND (42) ND (4500) ND (4300) ND (8500) ND (50) ND (45) ND (45) ND (460) ND (42) ND (4500) ND (4300) ND (8500) ND (50) ND (45) ND (45) ND (460) ND (42) ND (4500) ND (4300) ND (8500) ND (50) ND (45) ND (45) ND (460) ND (42) ND (4500) ND (4300) ND (8500) ND (50) 36 J ND (45) 2900 21 J 23000 18000 83000

31 J ND (45) ND (45) ND (460) ND (42) ND (4500) ND (4300) ND (8500) ND (50) 24 J ND (45) 880 ND (42) 3100 J 2400 J 9500

31 J 60 J 0 3,780 21 J 26,100 J 20,400 J 92,500

13968-32-T91.xls

Page 175: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 84 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

578 578 579 579 580 580 581 582S-00-013002-JH-578 S-00-013002-JH-578A S-00-013002-CH-579 S-00-013002-CH-579A S-00-013002-CH-580 S-00-013002-CH-580A S-00-013002-CH-581 S-00-013102-CH-582

1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/30/2002 1/31/2002(0-0.33) (0.33-0.667) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33)

ND (2300) ND (4500) ND (230) ND (43) ND (48) ND (45) ND (2300) ND (2400) ND (2300) ND (4500) ND (230) ND (43) ND (48) ND (45) ND (2300) ND (2400) ND (2300) ND (4500) ND (230) ND (43) ND (48) ND (45) ND (2300) ND (2400) ND (2300) ND (4500) ND (230) ND (43) ND (48) ND (45) ND (2300) ND (2400)

16000 22000 720 ND (43) ND (48) ND (45) 10000 17000 ND (2300) ND (4500) ND (230) ND (43) 98 ND (45) ND (2300) ND (2400)

2000 J 3100 J 120 J ND (43) ND (48) ND (45) 2300 ND (2400)

18,000 J 25,100 J 840 J 0 98 0 12,300 17,000

13968-32-T91.xls

Page 176: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 85 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

583 584 585 586 587 588 588 589 590S-00-013102-CH-583 S-00-013102-CH-584 S-00-013102-GS-585 S-00-013102-GS-586 S-00-013102-GS-587 S-00-013102-CH-588 S-00-013102-CH-588A S-00-013102-CH-589 S-00-013102-CH-590

1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (4300) ND (900) ND (2400) ND (960) ND (48) ND (4700) ND (5000) ND (4500) ND (1900) ND (4300) ND (900) ND (2400) ND (960) ND (48) ND (4700) ND (5000) ND (4500) ND (1900) ND (4300) ND (900) ND (2400) ND (960) ND (48) ND (4700) ND (5000) ND (4500) ND (1900) ND (4300) ND (900) ND (2400) ND (960) ND (48) ND (4700) ND (5000) ND (4500) ND (1900)

40000 5900 23000 8400 98 35000 29000 52000 17000 ND (4300) ND (900) ND (2400) ND (960) ND (48) ND (4700) ND (5000) ND (4500) ND (1900) ND (4300) 570 J ND (2400) 630 J 44 J ND (4700) ND (5000) ND (4500) 1200 J

40,000 6,470 J 23,000 9,030 J 142 J 35,000 29,000 52,000 18,200 J

13968-32-T91.xls

Page 177: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 86 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

590 591 592 593 594 595 596 597 598S-00-013102-CH-590A S-00-013102-CH-591 S-00-013102-GS-592 S-00-013102-GS-593 S-00-013102-GS-594 S-00-013102-JH-595 S-00-013102-CH-596 S-00-013102-CH-597 S-00-013102-CH-598

1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (1900) ND (2000) ND (2400) ND (46) ND (57) ND (50) ND (52) ND (510) ND (7000) ND (1900) ND (2000) ND (2400) ND (46) ND (57) ND (50) ND (52) ND (510) ND (7000) ND (1900) ND (2000) ND (2400) ND (46) ND (57) ND (50) ND (52) ND (510) ND (7000) ND (1900) ND (2000) ND (2400) ND (46) ND (57) ND (50) ND (52) ND (510) ND (7000)

16000 14000 12000 ND (46) ND (57) ND (50) ND (52) 3200 110000 ND (1900) ND (2000) ND (2400) 370 ND (57) ND (50) ND (52) ND (510) ND (7000) ND (1900) ND (2000) ND (2400) ND (46) ND (57) ND (50) ND (52) 390 J ND (7000)

16,000 14,000 12,000 370 0 0 0 3,590 J 110,000

13968-32-T91.xls

Page 178: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 87 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

599 600 600 601 602 603 604 605S-00-013102-CH-599 S-00-012102-LM-600 S-00-012102-LM-600A S-00-012102-LM-601 S-00-012102-LM-602 S-00-012102-LM-603 S-00-012102-LM-604 S-00-012102-LM-605

1/31/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (1000) ND (1900) ND (1900) ND (2200) ND (4200) ND (510) ND (49) ND (430) UJND (1000) ND (1900) ND (1900) ND (2200) ND (4200) ND (510) ND (49) ND (430) UJND (1000) ND (1900) ND (1900) ND (2200) ND (4200) ND (510) ND (49) ND (430) UJND (1000) ND (1900) ND (1900) ND (2200) ND (4200) ND (510) ND (49) ND (430) UJ

3500 13000 12000 6000 ND (4200) 5900 310 3700 JND (1000) ND (1900) ND (1900) ND (2200) 33000 ND (510) ND (49) ND (430) UJND (1000) 3100 3000 1900 J ND (4200) 2800 160 610 J

3,500 16,100 15,000 7,900 J 33,000 8,700 470 4,310 J

13968-32-T91.xls

Page 179: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 88 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

606 607 608 609 610 610 611 612S-00-012102-LM-606 S-00-012102-LM-607 S-00-012102-LM-608 S-00-012102-LM-609 S-00-012102-LM-610 S-00-012102-LM-610A S-00-012102-LM-611 S-00-012102-LM-612

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (4300) UJ ND (83) UJ ND (1100) ND (99) ND (95) ND (230) ND (47) ND (53) UJND (4300) UJ ND (83) UJ ND (1100) ND (99) ND (95) ND (230) ND (47) ND (53) UJND (4300) UJ ND (83) UJ ND (1100) ND (99) ND (95) ND (230) ND (47) ND (53) UJND (4300) UJ ND (83) UJ ND (1100) ND (99) ND (95) ND (230) ND (47) 200 J

29000 J 830 J 5200 360 940 510 31 J ND (53) UJND (4300) UJ ND (83) UJ ND (1100) ND (99) ND (95) ND (230) ND (47) ND (53) UJ

6900 J 250 J 2100 130 180 ND (230) 36 J 110 J

35,900 J 1,080 J 7,300 490 1,120 510 67 J 310 J

13968-32-T91.xls

Page 180: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 89 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

612 613 614 615 616 616 617 617S-00-012102-LM-612A S-00-012102-LM-613 S-00-012102-LM-614 S-00-012102-LM-615 S-00-012102-LM-616 S-00-012102-LM-616A S-00-012102-LM-617 S-00-012102-LM-617A

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

Duplicate

ND (54) ND (390) ND (43) ND (47) UJ ND (49) UJ ND (44) ND (450) ND (460) ND (54) ND (390) ND (43) ND (47) UJ ND (49) UJ ND (44) ND (450) ND (460) ND (54) ND (390) ND (43) ND (47) UJ ND (49) UJ ND (44) ND (450) ND (460) ND (54) ND (390) ND (43) ND (47) UJ 110 J ND (44) ND (450) ND (460)

79 3700 140 ND (47) UJ ND (49) UJ ND (44) ND (450) ND (460) ND (54) ND (390) ND (43) 41 J ND (49) UJ ND (44) 2800 1500

41 J 1300 90 ND (47) UJ 41 J 14 J ND (450) ND (460)

120 J 5,000 230 41 J 151 J 14 J 2,800 1,500

13968-32-T91.xls

Page 181: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 90 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

618 618 619 619 620 620 621 622 623S-00-012102-LM-618 S-00-012102-LM-618A S-00-012102-LM-619 S-00-012102-LM-619A S-00-LM620 S-00-012102-LM-620A S-00-012102-LM-621 S-00-012102-LM-622 S-00-012102-LM-623

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33)

ND (760) ND (390) ND (47) ND (42) ND (45) ND (44) ND (2100) ND (930) ND (48) ND (760) ND (390) ND (47) ND (42) ND (45) ND (44) ND (2100) ND (930) ND (48) ND (760) ND (390) ND (47) ND (42) ND (45) ND (44) ND (2100) ND (930) ND (48) ND (760) ND (390) ND (47) ND (42) ND (45) ND (44) ND (2100) ND (930) ND (48) ND (760) ND (390) ND (47) ND (42) 150 ND (44) 14000 11000 29 J

11000 2800 100 ND (42) ND (45) 190 ND (2100) ND (930) ND (48) ND (760) ND (390) ND (47) ND (42) 150 ND (44) 3600 2800 32 J

11,000 2,800 100 0 300 190 17,600 13,800 61 J

13968-32-T91.xls

Page 182: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 91 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

624S-00-012102-LM-624

1/21/2002(0-0.33)

ND (51) ND (51) ND (51) ND (51)

34 JND (51)

29 J

63 J

13968-32-T91.xls

Page 183: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 92 of 314

Sample Location: 625 626 627 628 629 630 630 631Sample ID: S-00-012102-LM-625 S-00-012102-LM-626 S-00-012102-LM-627 S-00-012102-LM-628 S-00-012102-LM-629 S-00-012102-LM-630 S-00-012102-LM-630A S-00-012102-LM-631Sample Date: 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002Sample Depth: (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (95) UJ ND (9300) UJ ND (4400) ND (48) ND (48) ND (2500) ND (4300) ND (5300) UJAroclor-1221 (PCB-1221) ug/Kg ND (95) UJ ND (9300) UJ ND (4400) ND (48) ND (48) ND (2500) ND (4300) ND (5300) UJAroclor-1232 (PCB-1232) ug/Kg ND (95) UJ ND (9300) UJ ND (4400) ND (48) ND (48) ND (2500) ND (4300) ND (5300) UJAroclor-1242 (PCB-1242) ug/Kg 430 J ND (9300) UJ ND (4400) ND (48) ND (48) ND (2500) ND (4300) ND (5300) UJAroclor-1248 (PCB-1248) ug/Kg ND (95) UJ 120000 J 38000 35 J 63 35000 39000 56000 JAroclor-1254 (PCB-1254) ug/Kg ND (95) UJ ND (9300) UJ ND (4400) ND (48) ND (48) ND (2500) ND (4300) ND (5300) UJAroclor-1260 (PCB-1260) ug/Kg 97 J 29000 J 9400 38 J 58 12000 14000 13000 J

Sum of Detected PCBs (ND=0) ug/Kg 527 J 149,000 J 47,400 73 J 121 47,000 53,000 69,000 J

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 184: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 93 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

632 633 634 634 635 635 636 636S-00-012102-LM-632 S-00-012102-LM-633 S-00-012102-LM-634 S-00-012102-LM-634A S-00-012102-LM-635 S-00-012102-LM-635A S-00-012102-LM-636 S-00-012102-LM-636A

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/21/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (4400) ND (46) ND (6200) ND (8900) ND (1900) ND (3800) UJ ND (3600) ND (8100) ND (4400) ND (46) ND (6200) ND (8900) ND (1900) ND (3800) UJ ND (3600) ND (8100) ND (4400) ND (46) ND (6200) ND (8900) ND (1900) ND (3800) UJ ND (3600) ND (8100) ND (4400) ND (46) ND (6200) ND (8900) ND (1900) ND (3800) UJ ND (3600) ND (8100)

49000 9.7 J 120000 180000 31000 42000 J 47000 96000 ND (4400) ND (46) ND (6200) ND (8900) ND (1900) ND (3800) UJ ND (3600) ND (8100)

8700 ND (46) 21000 43000 7100 14000 J 15000 24000

57,700 9.7 J 141,000 223,000 38,100 56,000 J 62,000 120,000

13968-32-T91.xls

Page 185: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 94 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

637 637 638 638 700 701 701 702S-00-012102-LM-637 S-00-012102-LM-637A S-00-012102-LM-638 S-00-012102-LM-638A S-00-013102-CH-700 S-00-013102-GS-701 S-00-013102-GS-701A S-00-013102-GS-702

1/21/2002 1/21/2002 1/21/2002 1/21/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (4500) ND (440) ND (44) UJ ND (43) ND (4700) ND (9300) ND (25000) ND (48) ND (4500) ND (440) ND (44) UJ ND (43) ND (4700) ND (9300) ND (25000) ND (48) ND (4500) ND (440) ND (44) UJ ND (43) ND (4700) ND (9300) ND (25000) ND (48) ND (4500) ND (440) 51 J ND (43) ND (4700) ND (9300) ND (25000) ND (48)

26000 1400 ND (44) UJ ND (43) 54000 170000 250000 ND (48) ND (4500) ND (440) ND (44) UJ ND (43) ND (4700) ND (9300) ND (25000) 53

9900 440 20 J ND (43) 4400 J ND (9300) ND (25000) ND (48)

35,900 1,840 71 J 0 58,400 J 170,000 250,000 53

13968-32-T91.xls

Page 186: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 95 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

703 704 704 705 706 707 708 708 709S-00-013102-CH-703 S-00-013102-CH-704 S-00-013102-CH-704A S-00-013102-CH-705 S-00-013102-CH-706 S-00-013102-CH-707 S-00-013102-CH-708 S-00-013102-CH-708A S-00-013102-CH-709

1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (220) ND (5100) ND (1100) ND (5000) ND (10000) ND (4700) ND (4700) ND (8800) ND (110) ND (220) ND (5100) ND (1100) ND (5000) ND (10000) ND (4700) ND (4700) ND (8800) ND (110) ND (220) ND (5100) ND (1100) ND (5000) ND (10000) ND (4700) ND (4700) ND (8800) ND (110) ND (220) ND (5100) ND (1100) ND (5000) ND (10000) ND (4700) ND (4700) ND (8800) ND (110)

640 32000 13000 25000 140000 40000 51000 100000 490 ND (220) ND (5100) ND (1100) ND (5000) ND (10000) ND (4700) ND (4700) ND (8800) ND (110) ND (220) ND (5100) ND (1100) ND (5000) ND (10000) ND (4700) 4300 J 8300 J 66 J

640 32,000 13,000 25,000 140,000 40,000 55,300 J 108,300 J 556 J

13968-32-T91.xls

Page 187: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 96 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

710 710 711 711 711 712 712 713 713S-00-013102-GS-710 S-00-013102-GS-710A S-00-013102-JH-711 S-00-013102-JH-711A S-00-013102-JH-711B S-00-013102-GS-712 S-00-013102-GS-712A S-00-013102-JH-713 S-00-013102-JH-713A

1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002(0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

Duplicate

ND (48) ND (43) ND (260) ND (260) ND (89) ND (480) ND (210) ND (290) ND (440) ND (48) ND (43) ND (260) ND (260) ND (89) ND (480) ND (210) ND (290) ND (440) ND (48) ND (43) ND (260) ND (260) ND (89) ND (480) ND (210) ND (290) ND (440) ND (48) ND (43) ND (260) ND (260) ND (89) ND (480) ND (210) ND (290) ND (440)

40 J 14 J ND (260) ND (260) ND (89) 1900 770 1600 630 ND (48) ND (43) 590 560 350 ND (480) ND (210) ND (290) ND (440) ND (48) ND (43) ND (260) ND (260) ND (89) 400 J 180 J ND (290) 130 J

40 J 14 J 590 560 350 2,300 J 950 J 1,600 760 J

13968-32-T91.xls

Page 188: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 97 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

714 714 715 715 716 716 717 717 718S-00-013102-GS-714 S-00-013102-GS-714A S-00-013102-GS-715 S-00-013102-GS-715A S-00-013102-JH-716 S-00-013102-JH-716A S-00-013102-JW-717 S-00-013102-JW-717A S-00-013102-JH-718

1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

ND (5000) ND (4300) ND (4500) ND (4200) ND (22000) ND (4300) ND (950) ND (86) ND (54) ND (5000) ND (4300) ND (4500) ND (4200) ND (22000) ND (4300) ND (950) ND (86) ND (54) ND (5000) ND (4300) ND (4500) ND (4200) ND (22000) ND (4300) ND (950) ND (86) ND (54) ND (5000) ND (4300) ND (4500) ND (4200) ND (22000) ND (4300) ND (950) ND (86) ND (54)

37000 42000 28000 46000 160000 21000 11000 440 130 ND (5000) ND (4300) ND (4500) ND (4200) ND (22000) ND (4300) ND (950) ND (86) ND (54) ND (5000) ND (4300) 3100 J 7200 19000 J 2000 J 950 64 J 26 J

37,000 42,000 31,100 J 53,200 179,000 J 23,000 J 11,950 504 J 156 J

13968-32-T91.xls

Page 189: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 98 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

718 719 720 721 722 723 723 724 725S-00-013102-JH-718A S-00-013102-GS-719 S-00-013102-GS-720 S-00-013102-GS-721 S-00-013102-TR-722 S-00-013102-TR-723 S-00-013102-TR-723A S-00-013102-TR-724 S-00-020102-CH-725

1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 1/31/2002 2/1/2002(0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (42) ND (51) ND (52) ND (49) ND (49) ND (45) ND (46) ND (49) ND (48) ND (42) ND (51) ND (52) ND (49) ND (49) ND (45) ND (46) ND (49) ND (48) ND (42) ND (51) ND (52) ND (49) ND (49) ND (45) ND (46) ND (49) ND (48) ND (42) ND (51) ND (52) ND (49) ND (49) ND (45) ND (46) ND (49) ND (48)

12 J ND (51) ND (52) ND (49) ND (49) ND (45) ND (46) ND (49) ND (48) ND (42) ND (51) 33 J ND (49) ND (49) ND (45) ND (46) ND (49) ND (48) ND (42) ND (51) ND (52) ND (49) ND (49) ND (45) ND (46) ND (49) ND (48)

12 J 0 33 J 0 0 0 0 0 0

13968-32-T91.xls

Page 190: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 99 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

726 726 727 728 729 735 736 736S-00-020102-GS-726 S-00-020102-GS-726A S-00-020102-GS-727 S-00-020102-GS-728 S-00-020102-GS-729 S-00-020402-MD-735 S-00-020402-CH-736 S-00-020402-CH-736A

2/1/2002 2/1/2002 2/1/2002 2/1/2002 2/1/2002 2/4/2002 2/4/2002 2/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (47) ND (52) ND (50) ND (52) ND (45) ND (56) ND (59) ND (59) ND (47) ND (52) ND (50) ND (52) ND (45) ND (56) ND (59) ND (59) ND (47) ND (52) ND (50) ND (52) ND (45) ND (56) ND (59) ND (59) ND (47) ND (52) ND (50) ND (52) 130 ND (56) ND (59) ND (59) ND (47) ND (52) ND (50) ND (52) ND (45) 26 J 210 ND (59) ND (47) ND (52) ND (50) ND (52) ND (45) ND (56) ND (59) 78 ND (47) ND (52) ND (50) ND (52) 16 J ND (56) 23 J ND (59)

0 0 0 0 146 J 26 J 233 J 78

13968-32-T91.xls

Page 191: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 100 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

737 738 739 740 741 742 743 744S-00-020402-CH-737 S-00-020402-LM-738 S-00-020402-LM-739 S-00-020402-LM-740 S-00-020402-CH-741 S-00-020402-LM-742 S-00-020402-MD-743 S-00-020402-LM-744

2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (230) ND (5000) ND (4200) ND (4600) ND (4900) ND (54) ND (49) ND (53) ND (230) ND (5000) ND (4200) ND (4600) ND (4900) ND (54) ND (49) ND (53) ND (230) ND (5000) ND (4200) ND (4600) ND (4900) ND (54) ND (49) ND (53) ND (230) ND (5000) ND (4200) ND (4600) ND (4900) ND (54) ND (49) ND (53) ND (230) 34000 39000 33000 42000 ND (54) 23 J 20 J

800 ND (5000) ND (4200) ND (4600) ND (4900) 120 ND (49) ND (53) ND (230) 3000 J 3400 J 3500 J 4200 J ND (54) ND (49) ND (53)

800 37,000 J 42,400 J 36,500 J 46,200 J 120 23 J 20 J

13968-32-T91.xls

Page 192: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 101 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

745 746 747 748 749 750 750 751S-00-020402-LM-745 S-00-020402-CH-746 S-00-020402-CH-747 S-00-020402-CH-748 S-00-020502-CH-749 S-00-020402-LM-750 S-00-020402-LM-750A S-00-020402-MD-751

2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/5/2002 2/4/2002 2/4/2002 2/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (47) ND (45) ND (47) ND (110) ND (570) ND (5300) ND (2700) ND (1000) ND (47) ND (45) ND (47) ND (110) ND (570) ND (5300) ND (2700) ND (1000) ND (47) ND (45) ND (47) ND (110) ND (570) ND (5300) ND (2700) ND (1000) ND (47) ND (45) ND (47) ND (110) ND (570) ND (5300) ND (2700) ND (1000)

14 J ND (45) ND (47) ND (110) 2100 44000 19000 9500 ND (47) ND (45) 150 510 ND (570) ND (5300) ND (2700) ND (1000) ND (47) ND (45) ND (47) ND (110) 290 J 4000 J 1600 J 770 J

14 J 0 150 510 2,390 J 48,000 J 20,600 J 10,270 J

13968-32-T91.xls

Page 193: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 102 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

752 753 754 755 756 756 757 758S-00-020402-MD-752 S-00-020402-LM-753 S-00-020402-JH-754 S-00-020402-JH-755 S-00-020402-JH-756 S-00-020402-JH-756A S-00-020402-CH-757 S-00-020402-JH-758

2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (1200) ND (2300) ND (2300) ND (100) ND (48) ND (49) ND (48) ND (51) ND (1200) ND (2300) ND (2300) ND (100) ND (48) ND (49) ND (48) ND (51) ND (1200) ND (2300) ND (2300) ND (100) ND (48) ND (49) ND (48) ND (51) ND (1200) ND (2300) ND (2300) ND (100) ND (48) ND (49) ND (48) ND (51)

10000 12000 15000 390 10 J ND (49) 30 J 7.5 JND (1200) ND (2300) ND (2300) ND (100) ND (48) ND (49) ND (48) ND (51)

780 J 920 J 1300 J 61 J ND (48) ND (49) ND (48) ND (51)

10,780 J 12,920 J 16,300 J 451 J 10 J 0 30 J 7.5 J

13968-32-T91.xls

Page 194: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 103 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

759 760 761 762 763 764 764 765S-00-020402-CH-759 S-00-020402-JH-760 S-00-020402-JH-761 S-00-020402-JH-762 S-00-020402-CH-763 S-00-020402-CH-764 S-00-020402-CH-764A S-00-020402-CH-765

2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (55) ND (52) ND (51) ND (46) ND (53) ND (55) ND (60) ND (53) ND (55) ND (52) ND (51) ND (46) ND (53) ND (55) ND (60) ND (53) ND (55) ND (52) ND (51) ND (46) ND (53) ND (55) ND (60) ND (53) ND (55) ND (52) ND (51) ND (46) ND (53) ND (55) ND (60) ND (53) ND (55) ND (52) ND (51) ND (46) 40 J ND (55) ND (60) ND (53) ND (55) ND (52) ND (51) ND (46) ND (53) ND (55) ND (60) ND (53) ND (55) ND (52) ND (51) ND (46) ND (53) ND (55) ND (60) ND (53)

0 0 0 0 40 J 0 0 0

13968-32-T91.xls

Page 195: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 104 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

766 767 768 768B 768B 768B 769 769S-00-020402-JH-766 S-00-020402-JH-767 S-00-020402-JH-768 S-00-020502-CH-768 S-00-020502-CH-768A S-00-020502-CH-768B S-00-020502-CH-769 S-00-020502-CH-769A

2/4/2002 2/4/2002 2/4/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (2-4) (0-0.33) (0.33-2)

ND (55) ND (50) ND (48) ND (51) ND (44) ND (45) ND (47) ND (41) ND (55) ND (50) ND (48) ND (51) ND (44) ND (45) ND (47) ND (41) ND (55) ND (50) ND (48) ND (51) ND (44) ND (45) ND (47) ND (41) ND (55) ND (50) ND (48) ND (51) ND (44) ND (45) ND (47) ND (41) ND (55) ND (50) ND (48) 80 39 J ND (45) ND (47) ND (41) ND (55) ND (50) ND (48) ND (51) ND (44) ND (45) 130 ND (41) ND (55) ND (50) ND (48) ND (51) ND (44) ND (45) ND (47) ND (41)

0 0 0 80 39 J 0 130 0

13968-32-T91.xls

Page 196: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 105 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

770 770 770 771 771 771 772 772S-00-020502-CH-770 S-00-020502-CH-770A S-00-020502-CH-770B S-00-020502-CH-771 S-00-020502-CH-771A S-00-020502-CH-771B S-00-020502-GS-772 S-00-020502-GS-772A

2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002(0-0.33) (0.33-2) (2-4) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

Duplicate

ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48) ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48) ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48) ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48) ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48) ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48) ND (58) ND (42) ND (44) ND (51) ND (49) ND (44) ND (56) ND (48)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 197: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 106 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

772 773 773 774 774 774 775 775S-00-020502-GS-772B S-00-020502-GS-773 S-00-020502-GS-773A S-00-020502-GS-774 S-00-020502-GS-774A S-00-020502-GS-774B S-00-020502-GS-775 S-00-020502-GS-775B

2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002(2-4) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (2-4) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48) ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48) ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48) ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48) ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48) ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48) ND (44) ND (50) ND (43) ND (47) ND (45) ND (44) ND (47) ND (48)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 198: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 107 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

775 776 777 778 779 779 780 781S-00-020502-GS-775A S-00-020402-JH-776 S-00-020402-CH-777 S-00-020402-JH-778 S-00-020402-CH-779 S-00-020402-CH-779A S-00-020402-CH-780 S-00-020402-CH-781

2/5/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002 2/4/2002(0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (43) ND (49) ND (51) ND (250) ND (1000) ND (1000) ND (990) ND (1200) ND (43) ND (49) ND (51) ND (250) ND (1000) ND (1000) ND (990) ND (1200) ND (43) ND (49) ND (51) ND (250) ND (1000) ND (1000) ND (990) ND (1200) ND (43) ND (49) ND (51) ND (250) ND (1000) ND (1000) ND (990) ND (1200) ND (43) ND (49) 20 J 700 5000 7400 6100 6900 ND (43) 91 ND (51) ND (250) ND (1000) ND (1000) ND (990) ND (1200) ND (43) ND (49) ND (51) 66 J 340 J 560 J 370 J 500 J

0 91 20 J 766 J 5,340 J 7,960 J 6,470 J 7,400 J

13968-32-T91.xls

Page 199: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 108 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

782 783 784 785 786 786 787 788S-00-020402-CH-782 S-00-020502-MD-783 S-00-020502-MD-784 S-00-020502-MD-785 S-00-020502-MD-786 S-00-020502-MD-786A S-00-020502-MD-787 S-00-020502-MD-788

2/4/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (47) ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55) ND (47) ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55) ND (47) ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55) ND (47) ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55)

130 ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55) ND (47) ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55)

18 J ND (45) ND (51) ND (48) ND (56) ND (80) ND (56) ND (55)

148 J 0 0 0 0 0 0 0

13968-32-T91.xls

Page 200: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 109 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

789 790 791 791 792 793 794 795S-00-020502-JH-789 S-00-020502-JH-790 S-00-020602-CH-791 S-00-020602-CH-791A S-00-020602-CH-792 S-00-020602-CH-793 S-00-020602-GS-794 S-00-020602-CH-795

2/5/2002 2/5/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46) ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46) ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46) ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46) ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46) ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46) ND (53) ND (49) ND (45) ND (45) ND (48) ND (48) ND (50) ND (46)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 201: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 110 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

796 797 798 799 799 800 800 801S-00-020602-GS-796 S-00-020602-CH-797 S-00-020602-CH-798 S-00-020602-GS-799 S-00-020602-GS-799A S-00-020602-JW-800 S-00-020602-JW-800A S-00-020602-JW-801

2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49) ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49) ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49) ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49) ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49) ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49) ND (52) ND (56) ND (55) ND (48) ND (47) ND (47) ND (46) ND (49)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 202: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 111 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

804 805 808 809 812 813 816 816S-00-020602-GS-804 S-00-020602-JH-805 S-00-020602-CH-808 S-00-020602-CH-809 S-00-020602-CH-812 S-00-020602-CH-813 S-00-020702-GS-816 S-00-020702-GS-816A

2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/6/2002 2/7/2002 2/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) ND (47) ND (46) ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) ND (47) ND (46) ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) ND (47) ND (46) ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) ND (47) ND (46) ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) 110 170 ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) ND (47) ND (46) ND (44) ND (48) ND (42) ND (43) ND (43) ND (43) 21 J 31 J

0 0 0 0 0 0 131 J 201 J

13968-32-T91.xls

Page 203: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 112 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

817 818 819 820 821 822 823 824S-00-020702-CH-817 S-00-020702-GS-818 S-00-020702-CH-819 S-00-020702-GS-820 S-00-020702-CH-821 S-00-020702-GS-822 S-00-020702-CH-823 S-00-020702-GS-824

2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (110) ND (4400) ND (12000) ND (580) ND (240) ND (230) ND (51) ND (47) ND (110) ND (4400) ND (12000) ND (580) ND (240) ND (230) ND (51) ND (47) ND (110) ND (4400) ND (12000) ND (580) ND (240) ND (230) ND (51) ND (47) ND (110) ND (4400) ND (12000) ND (580) ND (240) ND (230) ND (51) ND (47)

870 31000 62000 4100 1400 2400 25 J 13 JND (110) ND (4400) ND (12000) ND (580) ND (240) ND (230) ND (51) ND (47)

82 J 3200 J 7700 J 500 J 230 J 350 ND (51) ND (47)

952 J 34,200 J 69,700 J 4,600 J 1,630 J 2,750 25 J 13 J

13968-32-T91.xls

Page 204: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 113 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

825 826 826 827 828 829 830 831S-00-020702-GS-825 S-00-020702-GS-826 S-00-020702-GS-826A S-00-020702-GS-827 S-00-020702-CH-828 S-00-020702-CH-829 S-00-020702-GS-830 S-00-020702-GS-831

2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (49) ND (44) ND (45) ND (2300) ND (2200) ND (4700) ND (500) ND (260) ND (49) ND (44) ND (45) ND (2300) ND (2200) ND (4700) ND (500) ND (260) ND (49) ND (44) ND (45) ND (2300) ND (2200) ND (4700) ND (500) ND (260) ND (49) ND (44) ND (45) ND (2300) ND (2200) ND (4700) ND (500) ND (260)

7.5 J 16 J 16 J 19000 22000 32000 2900 1700 ND (49) ND (44) ND (45) ND (2300) ND (2200) ND (4700) ND (500) ND (260) ND (49) ND (44) ND (45) 1400 J 2000 J 2500 J 470 J 130 J

7.5 J 16 J 16 J 20,400 J 24,000 J 34,500 J 3,370 J 1,830 J

13968-32-T91.xls

Page 205: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 114 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

832 833 834 835 836 836 837 838S-00-020702-CH-832 S-00-020702-CH-833 S-00-020702-CH-834 S-00-020702-CH-835 S-00-020702-CH-836 S-00-020702-CH-836A S-00-020702-GS-837 S-00-020702-GS-838

2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002 2/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (280) ND (47) ND (90) ND (1100) ND (4600) ND (5000) ND (2400) ND (240) ND (280) ND (47) ND (90) ND (1100) ND (4600) ND (5000) ND (2400) ND (240) ND (280) ND (47) ND (90) ND (1100) ND (4600) ND (5000) ND (2400) ND (240) ND (280) ND (47) ND (90) ND (1100) ND (4600) ND (5000) ND (2400) ND (240)

2000 43 J 890 13000 26000 30000 15000 1700 ND (280) ND (47) ND (90) ND (1100) ND (4600) ND (5000) ND (2400) ND (240)

190 J 15 J 96 1100 2300 J 2500 J 2100 J 180 J

2,190 J 58 J 986 14,100 28,300 J 32,500 J 17,100 J 1,880 J

13968-32-T91.xls

Page 206: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 115 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

839 839 839 840 840 841 841 842S-00-021102-CH-839 S-00-021102-CH-839A S-00-021102-CH-839B S-00-021102-CH-840 S-00-021102-CH-840A S-00-021102-CH-841 S-00-021102-CH-841A S-00-021102-JW-842

2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002(0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (49) ND (50) ND (44) ND (550) ND (44) ND (470) ND (83) ND (980) ND (49) ND (50) ND (44) ND (550) ND (44) ND (470) ND (83) ND (980) ND (49) ND (50) ND (44) ND (550) ND (44) ND (470) ND (83) ND (980) ND (49) ND (50) ND (44) ND (550) ND (44) ND (470) ND (83) ND (980) ND (49) ND (50) ND (44) 5700 130 4600 700 6400 ND (49) ND (50) ND (44) ND (550) ND (44) ND (470) ND (83) ND (980) ND (49) ND (50) ND (44) 450 J ND (44) 620 100 990

0 0 0 6,150 J 130 5,220 800 7,390

13968-32-T91.xls

Page 207: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 116 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

842 843 843 844 844 844 845 845S-00-021102-JW-842A S-00-021102-JW-843 S-00-021102-JW-843A S-00-021102-JW-844 S-00-021102-JW-844A S-00-021102-JW-844B S-00-021102-JW-845 S-00-021102-JW-845A

2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

Duplicate

ND (430) ND (2300) ND (41) ND (2000) ND (1000) ND (43) ND (97) ND (44) ND (430) ND (2300) ND (41) ND (2000) ND (1000) ND (43) ND (97) ND (44) ND (430) ND (2300) ND (41) ND (2000) ND (1000) ND (43) ND (97) ND (44) ND (430) ND (2300) ND (41) ND (2000) ND (1000) ND (43) ND (97) ND (44)

2700 12000 230 18000 14000 180 1100 260 ND (430) ND (2300) ND (41) ND (2000) ND (1000) ND (43) ND (97) ND (44)

350 J 1700 J 25 J 2400 1800 15 J 140 25 J

3,050 J 13,700 J 255 J 20,400 15,800 195 J 1,240 285 J

13968-32-T91.xls

Page 208: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 117 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

846 846 847 848 849 850 851 852S-00-021102-JW-846 S-00-021102-JW-846A S-00-021102-CH-847 S-00-021102-JW-848 S-00-021102-CH-849 S-00-021102-CH-850 S-00-021102-JW-851 S-00-021102-CH-852

2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002(0-0.33) (0.33-1) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (50) ND (44) ND (67) ND (270) ND (480) ND (100) ND (110) ND (980) ND (50) ND (44) ND (67) ND (270) ND (480) ND (100) ND (110) ND (980) ND (50) ND (44) ND (67) ND (270) ND (480) ND (100) ND (110) ND (980) ND (50) ND (44) ND (67) ND (270) ND (480) ND (100) ND (110) ND (980)

46 J ND (44) 41 J 1400 3000 770 ND (110) 14000 ND (50) ND (44) ND (67) ND (270) ND (480) ND (100) 710 ND (980) ND (50) ND (44) ND (67) 220 J 550 290 ND (110) 1800

46 J 0 41 J 1,620 J 3,550 1,060 710 15,800

13968-32-T91.xls

Page 209: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 118 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

852 853 854 855 855 856 857 858 859S-00-021102-CH-852A S-00-021102-CH-853 S-00-021102-CH-854 S-00-021102-CH-855 S-00-021102-CH-855A S-00-021102-CH-856 S-00-021102-CH-857 S-00-021102-CH-858 S-00-021102-CH-859

2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (1000) ND (49) ND (44) ND (53) ND (51) ND (460) ND (470) ND (520) ND (880) ND (1000) ND (49) ND (44) ND (53) ND (51) ND (460) ND (470) ND (520) ND (880) ND (1000) ND (49) ND (44) ND (53) ND (51) ND (460) ND (470) ND (520) ND (880) ND (1000) ND (49) ND (44) ND (53) ND (51) ND (460) ND (470) ND (520) ND (880)

16000 ND (49) ND (44) ND (53) ND (51) 2900 4800 5600 7500 ND (1000) ND (49) ND (44) 470 610 ND (460) ND (470) ND (520) ND (880)

1900 ND (49) ND (44) ND (53) ND (51) ND (460) 730 580 1000

17,900 0 0 470 610 2,900 5,530 6,180 8,500

13968-32-T91.xls

Page 210: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 119 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

860 861 862 863 864 865 865 866S-00-021102-CH-860 S-00-021102-CH-861 S-00-021102-CH-862 S-00-021102-CH-863 S-00-021102-CH-864 S-00-021102-CH-865 S-00-021102-CH-865A S-00-021202-JW-866

2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/11/2002 2/12/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (290) ND (50) ND (54) ND (54) ND (50) ND (51) ND (50) ND (46) ND (290) ND (50) ND (54) ND (54) ND (50) ND (51) ND (50) ND (46) ND (290) ND (50) ND (54) ND (54) ND (50) ND (51) ND (50) ND (46) ND (290) ND (50) ND (54) ND (54) ND (50) ND (51) ND (50) ND (46)

1800 37 J ND (54) ND (54) ND (50) ND (51) ND (50) ND (46) ND (290) ND (50) 84 ND (54) ND (50) ND (51) ND (50) ND (46)

250 J ND (50) ND (54) ND (54) ND (50) ND (51) ND (50) ND (46)

2,050 J 37 J 84 0 0 0 0 0

13968-32-T91.xls

Page 211: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 120 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

867 868 868 869 870 871 871 872S-00-021202-JW-867 S-00-021202-JW-868 S-00-021202-JW-868A S-00-021202-JW-869 S-00-021202-JW-870 S-00-021402-MD-871 S-00-021402-MD-871A S-00-021402-MD-872

2/12/2002 2/12/2002 2/12/2002 2/12/2002 2/12/2002 2/14/2002 2/14/2002 2/14/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (50) ND (50) ND (51) ND (49) ND (46) ND (920) ND (920) ND (680) ND (50) ND (50) ND (51) ND (49) ND (46) ND (920) ND (920) ND (680) ND (50) ND (50) ND (51) ND (49) ND (46) ND (920) ND (920) ND (680) ND (50) ND (50) ND (51) ND (49) ND (46) ND (920) ND (920) ND (680) ND (50) ND (50) ND (51) 18 J ND (46) 5700 6700 3100 ND (50) ND (50) ND (51) ND (49) ND (46) ND (920) ND (920) ND (680) ND (50) ND (50) ND (51) ND (49) ND (46) 810 J 900 J 400 J

0 0 0 18 J 0 6,510 J 7,600 J 3,500 J

13968-32-T91.xls

Page 212: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 121 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

873 874 874 874 875 875 876 876S-00-021402-CH-873 S-00-021402-CH-874 S-00-021402-CH-874A S-00-021402-CH-874B S-00-021402-JW-875 S-00-021402-JW-875A S-00-021402-CH-876 S-00-021402-CH-876A

2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002(0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

Duplicate

ND (46) ND (47) ND (53) ND (40) ND (920) ND (2100) ND (2200) ND (210) ND (46) ND (47) ND (53) ND (40) ND (920) ND (2100) ND (2200) ND (210) ND (46) ND (47) ND (53) ND (40) ND (920) ND (2100) ND (2200) ND (210) ND (46) ND (47) ND (53) ND (40) ND (920) ND (2100) ND (2200) ND (210) ND (46) ND (47) ND (53) ND (40) U 7000 10000 13000 990

530 230 170 ND (40) ND (920) ND (2100) ND (2200) ND (210) ND (46) ND (47) ND (53) ND (40) 1000 2000 J 1800 J 140 J

530 230 170 0 8,000 12,000 J 14,800 J 1,130 J

13968-32-T91.xls

Page 213: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 122 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

877 877 878S-00-021402-JW-877 S-00-021402-JW-877A S-00-021402-CH-878

2/14/2002 2/14/2002 2/14/2002(0-0.33) (0.33-2) (0-0.33)

ND (930) ND (2100) ND (1100) ND (930) ND (2100) ND (1100) ND (930) ND (2100) ND (1100) ND (930) ND (2100) ND (1100)

9200 11000 5900 ND (930) ND (2100) ND (1100)

1300 1300 J 770 J

10,500 12,300 J 6,670 J

13968-32-T91.xls

Page 214: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 123 of 314

Sample Location: 878 879 880 881 882 882 883 884Sample ID: S-00-021402-CH-878A S-00-021402-JW-879 S-00-021402-JW-880 S-00-021402-JW-881 S-00-021402-JW-882 S-00-021402-JW-882A S-00-021402-JW-883 S-00-021502-CH-884Sample Date: 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/14/2002 2/15/2002Sample Depth: (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (42) ND (4700) ND (4800) ND (880) ND (920) ND (940) ND (48) ND (47) Aroclor-1221 (PCB-1221) ug/Kg ND (42) ND (4700) ND (4800) ND (880) ND (920) ND (940) ND (48) ND (47) Aroclor-1232 (PCB-1232) ug/Kg ND (42) ND (4700) ND (4800) ND (880) ND (920) ND (940) ND (48) ND (47) Aroclor-1242 (PCB-1242) ug/Kg ND (42) ND (4700) ND (4800) ND (880) ND (920) ND (940) ND (48) ND (47) Aroclor-1248 (PCB-1248) ug/Kg 240 15000 16000 7800 5000 5000 ND (48) ND (47) Aroclor-1254 (PCB-1254) ug/Kg ND (42) ND (4700) ND (4800) ND (880) ND (920) ND (940) 76 ND (47) Aroclor-1260 (PCB-1260) ug/Kg 34 J 2400 J 2100 J 1200 810 J 810 J ND (48) ND (47)

Sum of Detected PCBs (ND=0) ug/Kg 274 J 17,400 J 18,100 J 9,000 5,810 J 5,810 J 76 0

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 215: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 124 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

885 885 886 887 888 889 890 891S-00-021502-CH-885 S-00-021502-CH-885A S-00-021502-CH-886 S-00-021502-CH-887 S-00-021502-CH-888 S-00-021502-CH-889 S-00-021502-CH-890 S-00-021502-CH-891

2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (50) ND (1100) ND (870) ND (2300) ND (950) ND (4700) ND (4300) ND (48) ND (50) ND (1100) ND (870) ND (2300) ND (950) ND (4700) ND (4300) ND (48) ND (50) ND (1100) ND (870) ND (2300) ND (950) ND (4700) ND (4300) ND (48) ND (50) ND (1100) ND (870) ND (2300) ND (950) ND (4700) ND (4300) ND (48) ND (50) 6500 6400 11000 7300 16000 31000

200 200 ND (1100) ND (870) ND (2300) ND (950) ND (4700) ND (4300) ND (48) ND (50) 730 J 630 J 1700 J 1000 2100 J 4500

200 200 7,230 J 7,030 J 12,700 J 8,300 18,100 J 35,500

13968-32-T91.xls

Page 216: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 125 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

892 893 894 894 895 896 897 898S-00-021502-CH-892 S-00-021502-CH-893 S-00-021502-CH-894 S-00-021502-CH-894A S-00-021502-CH-895 S-00-021502-JK-896 S-00-021502-JK-897 S-00-021502-JW-898

2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (980) ND (46) ND (49) ND (48) ND (43) ND (43) ND (940) ND (4700) ND (980) ND (46) ND (49) ND (48) ND (43) ND (43) ND (940) ND (4700) ND (980) ND (46) ND (49) ND (48) ND (43) ND (43) ND (940) ND (4700) ND (980) ND (46) ND (49) ND (48) ND (43) ND (43) ND (940) ND (4700)

6000 ND (46) ND (49) ND (48) ND (43) ND (43) 6100 25000 ND (980) 220 ND (49) ND (48) ND (43) ND (43) ND (940) ND (4700)

1200 ND (46) ND (49) ND (48) ND (43) ND (43) 740 J 2600 J

7,200 220 0 0 0 0 6,840 J 27,600 J

13968-32-T91.xls

Page 217: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 126 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

899 900 900 901 901 902 902 903S-00-021502-JW-899 S-00-021502-JW-900 S-00-021502-JH-900A S-00-021502-JW-901 S-00-021502-JH-901A S-00-021502-JW-902 S-00-021502-JH-902A S-00-021502-JW-903

2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002(0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

ND (92) ND (49) ND (43) ND (49) ND (41) ND (46) ND (42) ND (4400) ND (92) ND (49) ND (43) ND (49) ND (41) ND (46) ND (42) ND (4400) ND (92) ND (49) ND (43) ND (49) ND (41) ND (46) ND (42) ND (4400) ND (92) ND (49) ND (43) ND (49) ND (41) ND (46) ND (42) ND (4400) ND (92) 14 J ND (43) ND (49) ND (41) ND (46) ND (42) ND (4400)

480 ND (49) ND (43) ND (49) ND (41) 48 J ND (42) 6000 ND (92) ND (49) ND (43) ND (49) ND (41) ND (46) ND (42) ND (4400)

480 14 J 0 0 0 48 J 0 6,000

13968-32-T91.xls

Page 218: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 127 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

903 903 904 904 905 905 906 906S-00-021502-JW-903A S-00-021502-JH-903B S-00-021502-JW-904 S-00-021502-JH-904A S-00-021502-JW-905 S-00-021502-JH-905A S-00-021502-JW-906 S-00-021502-JW-906A

2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (930) ND (80) ND (2400) ND (420) ND (2100) ND (40) ND (4700) ND (4700) ND (930) ND (80) ND (2400) ND (420) ND (2100) ND (40) ND (4700) ND (4700) ND (930) ND (80) ND (2400) ND (420) ND (2100) ND (40) ND (4700) ND (4700) ND (930) ND (80) ND (2400) ND (420) ND (2100) ND (40) ND (4700) ND (4700) ND (930) ND (80) 14000 3100 6000 470 25000 24000

3300 350 ND (2400) ND (420) ND (2100) ND (40) ND (4700) ND (4700) ND (930) ND (80) 1800 J 440 760 J 67 2800 J 2400 J

3,300 350 15,800 J 3,540 6,760 J 537 27,800 J 26,400 J

13968-32-T91.xls

Page 219: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 128 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

906 907 907 908 908 909 909 910S-00-021502-JH-906B S-00-021502-JW-907 S-00-021502-JH-907A S-00-021502-JW-908 S-00-021502-JH-908A S-00-021502-JW-909 S-00-021502-JH-909A S-00-021502-JW-910

2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002 2/15/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

ND (41000) ND (4800) ND (21000) ND (940) ND (410) ND (55) ND (460) ND (44) ND (41000) ND (4800) ND (21000) ND (940) ND (410) ND (55) ND (460) ND (44) ND (41000) ND (4800) ND (21000) ND (940) ND (410) ND (55) ND (460) ND (44) ND (41000) ND (4800) ND (21000) ND (940) ND (410) ND (55) ND (460) ND (44)

49000 18000 120000 8500 1800 ND (55) 580 ND (44) ND (41000) ND (4800) ND (21000) ND (940) ND (410) 150 ND (460) ND (44) ND (41000) 2400 J 10000 J 970 170 J ND (55) ND (460) ND (44)

49,000 20,400 J 130,000 J 9,470 1,970 J 150 580 0

13968-32-T91.xls

Page 220: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 129 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

910 911 911 912 913 914 915 916 917S-00-021502-JH-910A S-00-021802-CH-911 S-00-021802-CH-911A S-00-021802-CH-912 S-00-021802-CH-913 S-00-021802-CH-914 S-00-021802-CH-915 S-00-021802-CH-916 S-00-021802-CH-917

2/15/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002(0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (42) ND (51) ND (49) ND (2400) ND (4900) ND (51) ND (4400) ND (4800) ND (240) ND (42) ND (51) ND (49) ND (2400) ND (4900) ND (51) ND (4400) ND (4800) ND (240) ND (42) ND (51) ND (49) ND (2400) ND (4900) ND (51) ND (4400) ND (4800) ND (240) ND (42) ND (51) ND (49) ND (2400) ND (4900) ND (51) ND (4400) ND (4800) ND (240) ND (42) ND (51) ND (49) 16000 31000 ND (51) 19000 21000 ND (240) ND (42) ND (51) ND (49) ND (2400) ND (4900) 42 J ND (4400) ND (4800) 1200 ND (42) ND (51) ND (49) 2100 J 1700 J ND (51) 2000 J 1700 J ND (240)

0 0 0 18,100 J 32,700 J 42 J 21,000 J 22,700 J 1,200

13968-32-T91.xls

Page 221: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 130 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

918 918 919 920 921 922 923 924S-00-021802-CH-918 S-00-021802-CH-918A S-00-021802-CH-919 S-00-021802-CH-920 S-00-021802-CH-921 S-00-021802-CH-922 S-00-021802-CH-923 S-00-021802-CH-924

2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (500) ND (2400) ND (56) ND (50) ND (41) ND (46) ND (44) ND (91) ND (500) ND (2400) ND (56) ND (50) ND (41) ND (46) ND (44) ND (91) ND (500) ND (2400) ND (56) ND (50) ND (41) ND (46) ND (44) ND (91) ND (500) ND (2400) ND (56) ND (50) ND (41) ND (46) ND (44) ND (91)

8900 24000 ND (56) ND (50) 7.4 J 7.2 J ND (44) ND (91) ND (500) ND (2400) 450 ND (50) ND (41) ND (46) ND (44) 410

1100 2400 ND (56) ND (50) ND (41) ND (46) ND (44) ND (91)

10,000 26,400 450 0 7.4 J 7.2 J 0 410

13968-32-T91.xls

Page 222: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 131 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

925 926 927 928 928 929 930 931S-00-021802-CH-925 S-00-021802-CH-926 S-00-021802-CH-927 S-00-021802-CH-928 S-00-021802-CH-928A S-00-021802-CH-929 S-00-021802-CH-930 S-00-021802-CH-931

2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (900) ND (45) ND (320) ND (110) ND (110) ND (470) ND (950) ND (470) ND (900) ND (45) ND (320) ND (110) ND (110) ND (470) ND (950) ND (470) ND (900) ND (45) ND (320) ND (110) ND (110) ND (470) ND (950) ND (470) ND (900) ND (45) ND (320) ND (110) ND (110) ND (470) ND (950) ND (470)

10000 ND (45) 2100 1200 1300 4400 8000 2300 ND (900) ND (45) ND (320) ND (110) ND (110) ND (470) ND (950) ND (470)

980 ND (45) 190 J 150 170 690 1000 270 J

10,980 0 2,290 J 1,350 1,470 5,090 9,000 2,570 J

13968-32-T91.xls

Page 223: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 132 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

932 933 934 935 936 937 938 939S-00-021802-CH-932 S-00-021802-CH-933 S-00-021802-CH-934 S-00-021802-CH-935 S-00-021802-CH-936 S-00-021802-CH-937 S-00-021802-CH-938 S-00-021802-CH-939

2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002 2/18/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (520) ND (100) ND (46) ND (59) ND (43) ND (43) ND (46) ND (890) ND (520) ND (100) ND (46) ND (59) ND (43) ND (43) ND (46) ND (890) ND (520) ND (100) ND (46) ND (59) ND (43) ND (43) ND (46) ND (890) ND (520) ND (100) ND (46) ND (59) ND (43) ND (43) ND (46) ND (890)

3000 930 ND (46) ND (59) ND (43) ND (43) ND (46) 8800 ND (520) ND (100) ND (46) ND (59) ND (43) ND (43) 420 ND (890)

320 J 150 ND (46) ND (59) ND (43) ND (43) ND (46) 930

3,320 J 1,080 0 0 0 0 420 9,730

13968-32-T91.xls

Page 224: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 133 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

940 940 941 941 942 942 942 943S-00-021902-CH-940 S-00-021902-CH-940A S-00-021902-CH-941 S-00-021902-CH-941A S-00-021902-CH-942 S-00-021902-CH-942A S-00-021902-CH-942B S-00-021902-CH-943

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (44) ND (43) ND (52) ND (43) ND (230) ND (480) ND (43) ND (220) ND (44) ND (43) ND (52) ND (43) ND (230) ND (480) ND (43) ND (220) ND (44) ND (43) ND (52) ND (43) ND (230) ND (480) ND (43) ND (220) ND (44) ND (43) ND (52) ND (43) ND (230) ND (480) ND (43) ND (220) ND (44) ND (43) ND (52) ND (43) ND (230) ND (480) ND (43) ND (220)

ND (44) UJ ND (43) UJ 50 J ND (43) UJ 540 660 ND (43) 790 JND (44) UJ ND (43) UJ ND (52) ND (43) UJ ND (230) ND (480) ND (43) ND (220) UJ

0 0 50 J 0 540 660 0 790 J

13968-32-T91.xls

Page 225: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 134 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

943 944 944 945 945 946 946 946S-00-021902-CH-943A S-00-021902-JW-944 S-00-021902-JW-944A S-00-021902-GS-945 S-00-021902-GS-945A S-00-021902-GS-946 S-00-021902-GS-946A S-00-021902-GS-946B

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2)

Duplicate

ND (42) ND (220) ND (43) ND (86) ND (84) ND (210) ND (210) ND (41) ND (42) ND (220) ND (43) ND (86) ND (84) ND (210) ND (210) ND (41) ND (42) ND (220) ND (43) ND (86) ND (84) ND (210) ND (210) ND (41) ND (42) ND (220) ND (43) ND (86) ND (84) ND (210) ND (210) ND (41) ND (42) ND (220) 130 ND (86) ND (84) ND (210) ND (210) ND (41)

41 J 410 ND (43) 440 500 460 610 35 JND (42) ND (220) 13 J ND (86) ND (84) ND (210) ND (210) ND (41)

41 J 410 143 J 440 500 460 610 35 J

13968-32-T91.xls

Page 226: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 135 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

947 947 948 948 949 949 950 950S-00-021902-GS-947 S-00-021902-GS-947A S-00-021902-GS-948 S-00-021902-GS-948A S-00-021902-GS-949 S-00-021902-GS-949A S-00-021902-GS-950 S-00-021902-GS-950A

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (210) ND (84) ND (86) ND (41) ND (40) ND (41) ND (42) ND (41) ND (210) ND (84) ND (86) ND (41) ND (40) ND (41) ND (42) ND (41) ND (210) ND (84) ND (86) ND (41) ND (40) ND (41) ND (42) ND (41) ND (210) ND (84) ND (86) ND (41) ND (40) ND (41) ND (42) ND (41) ND (210) ND (84) ND (86) ND (41) ND (40) ND (41) ND (42) ND (41)

480 250 J 430 220 240 250 150 31 JND (210) ND (84) ND (86) ND (41) ND (40) ND (41) ND (42) ND (41)

480 250 J 430 220 240 250 150 31 J

13968-32-T91.xls

Page 227: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 136 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

951 951 953 953 953 954 954 955S-00-021902-GS-951 S-00-021902-GS-951A S-00-021902-GS-953 S-00-021902-GS-953A S-00-021902-GS-953B S-00-021902-GS-954 S-00-021902-GS-954A S-00-021902-GS-955

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (47) ND (41) ND (41) ND (42) ND (41) ND (41) ND (41) ND (38) ND (47) ND (41) ND (41) ND (42) ND (41) ND (41) ND (41) ND (38) ND (47) ND (41) ND (41) ND (42) ND (41) ND (41) ND (41) ND (38) ND (47) ND (41) ND (41) ND (42) ND (41) ND (41) ND (41) ND (38) ND (47) ND (41) ND (41) ND (42) ND (41) ND (41) ND (41) ND (38)

43 J ND (41) 36 J 33 J ND (41) ND (41) ND (41) ND (38) ND (47) ND (41) ND (41) ND (42) ND (41) ND (41) ND (41) ND (38)

43 J 0 36 J 33 J 0 0 0 0

13968-32-T91.xls

Page 228: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 137 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

955 956 957 958 959 960 960 961S-00-021902-GS-955A S-00-021902-CH-956 S-00-021902-CH-957 S-00-021902-CH-958 S-00-021902-CH-959 S-00-021902-CH-960 S-00-021902-CH-960A S-00-021902-CH-961

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (41) ND (41) ND (43) ND (42) ND (230) ND (420) ND (430) ND (460) ND (41) ND (41) ND (43) ND (42) ND (230) ND (420) ND (430) ND (460) ND (41) ND (41) ND (43) ND (42) ND (230) ND (420) ND (430) ND (460) ND (41) ND (41) ND (43) ND (42) ND (230) ND (420) ND (430) ND (460) ND (41) ND (41) ND (43) ND (42) 2400 8000 5600 4400 ND (41) 85 110 120 ND (230) ND (420) ND (430) ND (460) ND (41) ND (41) ND (43) ND (42) 330 980 930 810

0 85 110 120 2,730 8,980 6,530 5,210

13968-32-T91.xls

Page 229: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 138 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

962 963 964 965 966 967 968 968S-00-021902-CH-962 S-00-021902-GS-963 S-00-021902-GS-964 S-00-021902-GS-965 S-00-021902-GS-966 S-00-021902-GS-967 S-00-021902-GS-968 S-00-021902-GS-968A

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (92) ND (41) ND (42) ND (43) ND (41) ND (42) ND (41) ND (82) ND (92) ND (41) ND (42) ND (43) ND (41) ND (42) ND (41) ND (82) ND (92) ND (41) ND (42) ND (43) ND (41) ND (42) ND (41) ND (82) ND (92) ND (41) ND (42) ND (43) ND (41) ND (42) ND (41) ND (82)

1300 85 58 ND (43) 460 ND (42) ND (41) ND (82) ND (92) ND (41) ND (42) 74 ND (41) 72 140 170

180 36 J 25 J ND (43) 83 ND (42) ND (41) ND (82)

1,480 121 J 83 J 74 543 72 140 170

13968-32-T91.xls

Page 230: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 139 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

969 970 971 972 973 974 975 975S-00-021902-GS-969 S-00-021902-GS-970 S-00-021902-GS-971 S-00-021902-GS-972 S-00-021902-JW-973 S-00-021902-JW-974 S-00-021902-CH-975 S-00-021902-CH-975A

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (57) ND (41) ND (40) ND (45) ND (940) ND (450) ND (44) ND (43) ND (57) ND (41) ND (40) ND (45) ND (940) ND (450) ND (44) ND (43) ND (57) ND (41) ND (40) ND (45) ND (940) ND (450) ND (44) ND (43) ND (57) ND (41) ND (40) ND (45) ND (940) ND (450) ND (44) ND (43) ND (57) 39 J 7.6 J 7.2 J 5200 3100 ND (44) ND (43) ND (57) ND (41) ND (40) ND (45) ND (940) ND (450) ND (44) ND (43) ND (57) 14 J ND (40) ND (45) 930 J 520 ND (44) ND (43)

0 53 J 7.6 J 7.2 J 6,130 J 3,620 0 0

13968-32-T91.xls

Page 231: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 140 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

976 977 978 979 980 981 982 983S-00-021902-CH-976 S-00-021902-CH-977 S-00-021902-CH-978 S-00-021902-CH-979 S-00-021902-CH-980 S-00-021902-CH-981 S-00-021902-CH-982 S-00-021902-CH-983

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (45) ND (44) ND (47) ND (45) ND (45) ND (46) ND (45) ND (43) ND (45) ND (44) ND (47) ND (45) ND (45) ND (46) ND (45) ND (43) ND (45) ND (44) ND (47) ND (45) ND (45) ND (46) ND (45) ND (43) ND (45) ND (44) ND (47) ND (45) ND (45) ND (46) ND (45) ND (43)

23 J ND (44) 14 J 170 130 420 ND (45) ND (43) ND (45) 100 ND (47) ND (45) ND (45) ND (46) 200 580

10 J ND (44) ND (47) 50 46 97 ND (45) ND (43)

33 J 100 14 J 220 176 517 200 580

13968-32-T91.xls

Page 232: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 141 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

984 985 986 986 987 988 989 990S-00-021902-CH-984 S-00-021902-CH-985 S-00-021902-CH-986 S-00-021902-CH-986A S-00-021902-CH-987 S-00-021902-CH-988 S-00-021902-CH-989 S-00-021902-CH-990

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (43) ND (42) ND (42) ND (44) ND (96) ND (45) ND (92) ND (45) ND (43) ND (42) ND (42) ND (44) ND (96) ND (45) ND (92) ND (45) ND (43) ND (42) ND (42) ND (44) ND (96) ND (45) ND (92) ND (45) ND (43) ND (42) ND (42) ND (44) ND (96) ND (45) ND (92) ND (45) ND (43) ND (42) ND (42) 85 830 62 1000 160

100 130 260 ND (44) ND (96) ND (45) ND (92) ND (45) ND (43) ND (42) ND (42) 26 J 180 18 J 240 38 J

100 130 260 111 J 1,010 80 J 1,240 198 J

13968-32-T91.xls

Page 233: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 142 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

991 992 993 994 995 996 996 997S-00-021902-CH-991 S-00-021902-CH-992 S-00-021902-CH-993 S-00-021902-CH-994 S-00-021902-CH-995 S-00-021902-CH-996 S-00-021902-CH-996A S-00-021902-CH-997

2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002 2/19/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (240) ND (53) ND (240) ND (46) ND (85) ND (230) ND (220) ND (44) ND (240) ND (53) ND (240) ND (46) ND (85) ND (230) ND (220) ND (44) ND (240) ND (53) ND (240) ND (46) ND (85) ND (230) ND (220) ND (44) ND (240) ND (53) ND (240) ND (46) ND (85) ND (230) ND (220) ND (44)

1300 1000 1500 730 1400 3500 4200 340 ND (240) ND (53) ND (240) ND (46) ND (85) ND (230) ND (220) ND (44)

270 110 300 120 220 320 570 69

1,570 1110 1,800 850 1,620 3,820 4,770 409

13968-32-T91.xls

Page 234: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 143 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

998 999 1000 1000 1001 1002 1003 1004S-00-021902-CH-998 S-00-021902-CH-999 S-00-022002-CH-1000 S-00-022002-CH-1000A S-00-022002-CH-1001 S-00-022002-CH-1002 S-00-022002-CH-1003 S-00-022002-CH-1004

2/19/2002 2/19/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (230) ND (220) ND (110) ND (480) ND (520) ND (53) ND (91) ND (48) ND (230) ND (220) ND (110) ND (480) ND (520) ND (53) ND (91) ND (48) ND (230) ND (220) ND (110) ND (480) ND (520) ND (53) ND (91) ND (48) ND (230) ND (220) ND (110) ND (480) ND (520) ND (53) ND (91) ND (48)

1500 770 700 1800 1800 ND (53) ND (91) ND (48) ND (230) ND (220) ND (110) ND (480) ND (520) 99 300 J 35 J

310 160 J 110 270 J 340 J ND (53) ND (91) ND (48)

1,810 930 J 810 2,070 J 2,140 J 99 300 J 35 J

13968-32-T91.xls

Page 235: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 144 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1005 1009 1010 1010 1011 1012 1012 1013S-00-022002-CH-1005 S-00-022002-CH-1009 S-00-022002-CH-1010 S-00-022002-CH-1010A S-00-022002-CH-1011 S-00-022002-CH-1012 S-00-022002-CH-1012A S-00-022002-CH-1013

2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (47) ND (49) ND (52) ND (48) ND (49) ND (92) ND (42) ND (43) ND (47) ND (49) ND (52) ND (48) ND (49) ND (92) ND (42) ND (43) ND (47) ND (49) ND (52) ND (48) ND (49) ND (92) ND (42) ND (43) ND (47) ND (49) ND (52) ND (48) ND (49) ND (92) ND (42) ND (43) ND (47) ND (49) ND (52) ND (48) ND (49) 390 ND (42) ND (43) ND (47) ND (49) 44 J 110 140 ND (92) 47 46 ND (47) ND (49) ND (52) ND (48) ND (49) 87 J ND (42) ND (43)

0 0 44 J 110 140 477 J 47 46

13968-32-T91.xls

Page 236: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 145 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1013 1014 1014 1015 1015 1016 1016 1017S-00-022002-CH-1013A S-00-022002-CH-1014 S-00-022002-CH-1014A S-00-022002-CH-1015 S-00-022002-CH-1015A S-00-022002-CH-1016 S-00-022002-CH-1016A S-00-022002-JW-1017

2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

ND (42) ND (46) ND (47) ND (43) ND (51) ND (51) ND (42) ND (58) ND (42) ND (46) ND (47) ND (43) ND (51) ND (51) ND (42) ND (58) ND (42) ND (46) ND (47) ND (43) ND (51) ND (51) ND (42) ND (58) ND (42) ND (46) ND (47) ND (43) ND (51) ND (51) ND (42) ND (58) ND (42) ND (46) ND (47) ND (43) ND (51) 26 J ND (42) 78 ND (42) 53 ND (47) ND (43) 160 ND (51) ND (42) ND (58) ND (42) ND (46) ND (47) ND (43) ND (51) ND (51) ND (42) ND (58)

0 53 0 0 160 26 J 0 78

13968-32-T91.xls

Page 237: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 146 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1018 1019 1021 1022 1023 1024 1024 1025S-00-022002-LM-1018 S-00-022002-JW-1019 S-00-022002-JW-1021 S-00-022002-JW-1022 S-00-022002-JW-1023 S-00-022002-JW-1024 S-00-022002-JW-1024A S-00-022002-LM-1025

2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (490) ND (43) ND (47) ND (450) ND (90) ND (45) ND (51) ND (46) ND (490) ND (43) ND (47) ND (450) ND (90) ND (45) ND (51) ND (46) ND (490) ND (43) ND (47) ND (450) ND (90) ND (45) ND (51) ND (46) ND (490) ND (43) ND (47) ND (450) ND (90) ND (45) ND (51) ND (46) 2500 ND (43) ND (47) ND (450) ND (90) 280 620

190 ND (490) 54 43 J 1600 250 J ND (45) ND (51) ND (46) 360 J ND (43) ND (47) ND (450) ND (90) 76 89

190 2,860 J 54 43 J 1,600 250 J 356 709

13968-32-T91.xls

Page 238: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 147 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1026 1027 1028 1029 1030 1030 1031 1032S-00-022002-LM-1026 S-00-022002-JW-1027 S-00-022002-JW-1028 S-00-022002-JW-1029 S-00-022002-JW-1030 S-00-022002-JW-1030A S-00-022002-JW-1031 S-00-022102-CH-1032

2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/20/2002 2/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (44) ND (52) ND (48) ND (46) ND (46) ND (48) ND (44) ND (48) ND (44) ND (52) ND (48) ND (46) ND (46) ND (48) ND (44) ND (48) ND (44) ND (52) ND (48) ND (46) ND (46) ND (48) ND (44) ND (48) ND (44) ND (52) ND (48) ND (46) ND (46) ND (48) ND (44) ND (48) ND (44) ND (52) ND (48) ND (46) ND (46) ND (48) ND (44) ND (48) ND (44) ND (52) ND (48) ND (46) 50 ND (48) 44 ND (48) ND (44) ND (52) ND (48) ND (46) ND (46) ND (48) ND (44)

0 0 0 0 0 50 0 44

13968-32-T91.xls

Page 239: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 148 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1033 1033 1034 1035 1036 1037 1038 1039S-00-022102-MD-1033 S-00-022102-MD-1033A S-00-022102-MD-1034 S-00-022102-MD-1035 S-00-022102-CH-1036 S-00-022102-CH-1037 S-00-022102-MD-1038 S-00-022102-CH-1039

2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (50) ND (48) ND (49) ND (44) ND (85) ND (45) ND (47) ND (47) ND (50) ND (48) ND (49) ND (44) ND (85) ND (45) ND (47) ND (47) ND (50) ND (48) ND (49) ND (44) ND (85) ND (45) ND (47) ND (47) ND (50) ND (48) ND (49) ND (44) ND (85) ND (45) ND (47) ND (47) ND (50) ND (48) 230 130 470 280 120 ND (47) ND (50) 69 ND (49) ND (44) ND (85) ND (45) ND (47) ND (47) ND (50) ND (48) 40 J 34 J 140 93 35 J ND (47)

0 69 270 J 164 J 610 373 155 J 0

13968-32-T91.xls

Page 240: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 149 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1040 1041 1042 1043 1044 1045 1046 1046S-00-022102-MD-1040 S-00-022102-MD-1041 S-00-022102-CH-1042 S-00-022102-MD-1043 S-00-022102-MD-1044 S-00-022102-MD-1045 S-00-022102-CH-1046 S-00-022102-CH-1046A

2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (45) ND (43) ND (44) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (44) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (44) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (44) ND (43) ND (44) ND (44) ND (43)

52 88 ND (43) 220 80 ND (44) ND (44) ND (43) ND (44) ND (45) 77 ND (44) ND (43) ND (44) 57 110

15 J 20 J ND (43) 56 19 J ND (44) ND (44) ND (43)

67 J 108 J 77 276 99 J 0 57 110

13968-32-T91.xls

Page 241: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 150 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1047 1047 1048 1049 1049 1050 1051 1051S-00-022102-CH-1047 S-00-022102-CH-1047A S-00-022102-CH-1048 S-00-022102-CH-1049 S-00-022102-CH-1049A S-00-022102-CH-1050 S-00-022102-LM-1051 S-00-022102-LM-1051A

2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002(0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (43) ND (44) ND (47) ND (43) ND (45) ND (43) ND (44) ND (46) ND (43) ND (44) ND (47) ND (43) ND (45) ND (43) ND (44) ND (46) ND (43) ND (44) ND (47) ND (43) ND (45) ND (43) ND (44) ND (46) ND (43) ND (44) ND (47) ND (43) ND (45) ND (43) ND (44) ND (46) ND (43) ND (44) ND (47) ND (43) ND (45) ND (43) 160 ND (46) ND (43) 78 190 ND (43) 130 83 ND (44)

16 J ND (43) ND (44) ND (47) ND (43) ND (45) ND (43) 32 J

16 J 0 78 190 0 130 83 192 J

13968-32-T91.xls

Page 242: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 151 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1051 1052 1053 1053 1054 1055 1055 1056S-00-022102-LM-1051B S-00-022102-LM-1052 S-00-022102-CH-1053 S-00-022102-CH-1053A S-00-022102-MD-1054 S-00-022102-CH-1055 S-00-022102-CH-1055A S-00-022102-CH-1056

2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002(0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33)

ND (43) ND (470) ND (930) ND (42) ND (490) ND (510) ND (43) ND (49) ND (43) ND (470) ND (930) ND (42) ND (490) ND (510) ND (43) ND (49) ND (43) ND (470) ND (930) ND (42) ND (490) ND (510) ND (43) ND (49) ND (43) ND (470) ND (930) ND (42) ND (490) ND (510) ND (43) ND (49) ND (43) ND (470) 6200 230 2500 5800 ND (43) ND (49) ND (43) 1700 ND (930) ND (42) ND (490) ND (510) ND (43) 81 ND (43) ND (470) 850 J 28 J 310 J 540 ND (43) ND (49)

0 1,700 7,050 J 258 J 2,810 J 6,340 0 81

13968-32-T91.xls

Page 243: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 152 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1057 1057 1058 1059 1061 1062 1063 1063S-00-022102-CH-1057 S-00-022102-CH-1057A S-00-022102-MD-1058 S-00-022102-MD-1059 S-00-022102-MD-1061 S-00-022102-MD-1062 S-00-022102-MD-1063 S-00-022102-MD-1063A

2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002 2/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (43) ND (42) ND (88) ND (47) ND (49) ND (45) ND (44) ND (44) ND (43) ND (42) ND (88) ND (47) ND (49) ND (45) ND (44) ND (44) ND (43) ND (42) ND (88) ND (47) ND (49) ND (45) ND (44) ND (44) ND (43) ND (42) ND (88) ND (47) ND (49) ND (45) ND (44) ND (44)

370 ND (42) 620 ND (47) ND (49) ND (45) 480 400 ND (43) ND (42) ND (88) ND (47) 48 J ND (45) ND (44) ND (44)

91 ND (42) 92 ND (47) ND (49) ND (45) 65 60

461 0 712 0 48 J 0 545 460

13968-32-T91.xls

Page 244: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 153 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1064 1065 1066 1066 1067 1068 1069S-00-022202-CH-1064 S-00-022202-CH-1065 S-00-022202-MD-1066 S-00-022202-MD-1066A S-00-022202-LM-1067 S-00-022202-MD-1068 S-00-022202-CH-1069

2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (85) ND (97) ND (44) ND (44) ND (44) ND (48) ND (110) ND (85) ND (97) ND (44) ND (44) ND (44) ND (48) ND (110) ND (85) ND (97) ND (44) ND (44) ND (44) ND (48) ND (110) ND (85) ND (97) ND (44) ND (44) ND (44) ND (48) ND (110)

840 830 120 370 ND (44) 150 660 ND (85) ND (97) ND (44) ND (44) ND (44) ND (48) ND (110)

120 100 18 J 51 ND (44) 19 J 130

960 930 138 J 421 0 169 J 790

13968-32-T91.xls

Page 245: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 154 of 314

Sample Location: 1070 1071 1072 1073 1074 1074 1075 1076Sample ID: S-00-022202-CH-1070 S-00-022202-CH-1071 S-00-022202-CH-1072 S-00-022202-MD-1073 S-00-022202-MD-1074 S-00-022202-MD-1074A S-00-022202-CH-1075 S-00-022202-CH-1076Sample Date: 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002Sample Depth: (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (97) ND (48) ND (46) ND (44) ND (46) ND (47) ND (47) ND (46) Aroclor-1221 (PCB-1221) ug/Kg ND (97) ND (48) ND (46) ND (44) ND (46) ND (47) ND (47) ND (46) Aroclor-1232 (PCB-1232) ug/Kg ND (97) ND (48) ND (46) ND (44) ND (46) ND (47) ND (47) ND (46) Aroclor-1242 (PCB-1242) ug/Kg ND (97) ND (48) ND (46) ND (44) ND (46) ND (47) ND (47) ND (46) Aroclor-1248 (PCB-1248) ug/Kg 1000 320 ND (46) ND (44) 26 J 22 J ND (47) ND (46) Aroclor-1254 (PCB-1254) ug/Kg ND (97) ND (48) 100 ND (44) ND (46) ND (47) ND (47) ND (46) Aroclor-1260 (PCB-1260) ug/Kg 130 35 J ND (46) ND (44) ND (46) ND (47) ND (47) ND (46)

Sum of Detected PCBs (ND=0) ug/Kg 1,130 355 J 100 0 26 J 22 J 0 0

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 246: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 155 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1077 1078 1079 1080 1081 1081 1082 1082S-00-022202-MD-1077 S-00-022202-LM-1078 S-00-022202-JW-1079 S-00-022202-CH-1080 S-00-022202-CH-1081 S-00-022202-CH-1081A S-00-022202-MD-1082 S-00-022202-CH-1082A

2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2)

ND (44) ND (88) ND (220) ND (47) ND (44) ND (44) ND (44) ND (43) ND (44) ND (88) ND (220) ND (47) ND (44) ND (44) ND (44) ND (43) ND (44) ND (88) ND (220) ND (47) ND (44) ND (44) ND (44) ND (43) ND (44) ND (88) ND (220) ND (47) ND (44) ND (44) ND (44) ND (43)

140 410 1100 240 ND (44) ND (44) ND (44) ND (43) ND (44) ND (88) ND (220) ND (47) 42 J ND (44) 86 ND (43)

49 91 130 J 67 ND (44) ND (44) ND (44) ND (43)

189 501 1,230 J 307 42 J 0 86 0

13968-32-T91.xls

Page 247: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 156 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1083 1083 1084 1084 1085 1085 1085 1086S-00-022202-MD-1083 S-00-022202-CH-1083A S-00-022202-MD-1084 S-00-022202-CH-1084A S-00-022202-LM-1085 S-00-022202-LM-1085A S-00-022202-LM-1085B S-00-022602-GS-1086

2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/22/2002 2/26/2002(0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (230) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (230) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (230) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) ND (230) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) 1800

33 J ND (44) 32 J ND (43) ND (44) 28 J ND (43) ND (230) ND (43) ND (44) ND (44) ND (43) ND (44) ND (45) ND (43) 300

33 J 0 32 J 0 0 28 J 0 2,100

13968-32-T91.xls

Page 248: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 157 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1086 1087 1089 1090 1091 1091 1092 1093S-00-022602-GS-1086A S-00-022602-CH-1087 S-00-022502-JW-1089 S-00-022502-CH-1090 S-00-022502-GS-1091 S-00-022502-GS-1091A S-00-022502-GS-1092 S-00-022502-CH-1093

2/26/2002 2/26/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (450) ND (45) ND (110) ND (89) ND (240) ND (240) ND (230) ND (45) ND (450) ND (45) ND (110) ND (89) ND (240) ND (240) ND (230) ND (45) ND (450) ND (45) ND (110) ND (89) ND (240) ND (240) ND (230) ND (45) ND (450) ND (45) ND (110) ND (89) ND (240) ND (240) ND (230) ND (45)

3800 450 1600 ND (89) ND (240) 2400 1900 450 ND (450) ND (45) ND (110) 820 2100 ND (240) ND (230) ND (45)

570 65 J 320 ND (89) ND (240) 410 230 96

4,370 515 J 1,920 820 2,100 2,810 2,130 546

13968-32-T91.xls

Page 249: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 158 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1094 1095 1096 1097 1098 1099 1100 1101S-00-022502-GS-1094 S-00-022502-CH-1095 S-00-022502-GS-1096 S-00-022502-CH-1097 S-00-022502-GS-1098 S-00-022502-CH-1099 S-00-022502-CH-1100 S-00-022502-GS-1101

2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (44) ND (230) ND (86) ND (47) ND (44) ND (48000) ND (45) ND (48) ND (44) ND (230) ND (86) ND (47) ND (44) ND (48000) ND (45) ND (48) ND (44) ND (230) ND (86) ND (47) ND (44) ND (48000) ND (45) ND (48) ND (44) ND (230) ND (86) ND (47) ND (44) ND (48000) ND (45) ND (48)

16 J 960 940 ND (47) 290 180000 100 51 ND (44) ND (230) ND (86) 89 ND (44) ND (48000) ND (45) ND (48) ND (44) 99 J 190 ND (47) 36 J ND (48000) ND (45) ND (48)

16 J 1,059 J 1,130 89 326 J 180,000 100 51

13968-32-T91.xls

Page 250: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 159 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1102 1103 1103 1104 1105 1106 1106 1107S-00-022502-CH-1102 S-00-022502-CH-1103 S-00-022502-CH-1103A S-00-022502-GS-1104 S-00-022502-CH-1105 S-00-022502-CH-1106 S-00-022502-CH-1106A S-00-022502-JW-1107

2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (46) ND (44) ND (44) ND (45) ND (51) ND (44) ND (45) ND (45) ND (46) ND (44) ND (44) ND (45) ND (51) ND (44) ND (45) ND (45) ND (46) ND (44) ND (44) ND (45) ND (51) ND (44) ND (45) ND (45) ND (46) ND (44) ND (44) ND (45) ND (51) ND (44) ND (45) ND (45)

190 66 J 49 J 140 J ND (51) ND (44) ND (45) ND (45) ND (46) ND (44) ND (44) ND (45) ND (51) ND (44) ND (45) 36 J

22 J 29 J 20 J 34 J ND (51) ND (44) ND (45) ND (45)

212 J 95 J 69 J 174 J 0 0 0 36 J

13968-32-T91.xls

Page 251: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 160 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1108 1109 1110 1111 1112 1112 1113 1114S-00-022502-JW-1108 S-00-022502-GS-1109 S-00-022502-JW-1110 S-00-022502-JW-1111 S-00-022502-CH-1112 S-00-022502-CH-1112A S-00-022502-CH-1113 S-00-022502-GS-1114

2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (42) ND (44) ND (80) ND (47) ND (45) ND (48) ND (53) ND (48) ND (42) ND (44) ND (80) ND (47) ND (45) ND (48) ND (53) ND (48) ND (42) ND (44) ND (80) ND (47) ND (45) ND (48) ND (53) ND (48) ND (42) ND (44) ND (80) ND (47) ND (45) ND (48) ND (53) ND (48) ND (42) ND (44) 390 30 J 33 J 130 ND (53)

40 J ND (42) 27 J ND (80) ND (47) ND (45) ND (48) 240 ND (48) ND (42) ND (44) 76 J ND (47) ND (45) ND (48) ND (53)

40 J 0 27 J 466 J 30 J 33 J 130 240

13968-32-T91.xls

Page 252: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 161 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1115 1115 1116 1117 1118 1121 1122 1123S-00-022502-CH-1115 S-00-022502-CH-1115A S-00-022502-CH-1116 S-00-022502-CH-1117 S-00-022502-CH-1118 S-00-022502-GS-1121 S-00-022602-CH-1122 S-00-022602-CH-1123

2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/25/2002 2/26/2002 2/26/2002(0-0.33) (0.33-0.83) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (50) ND (44) ND (52) ND (51) ND (47) ND (47) ND (44) ND (48) ND (50) ND (44) ND (52) ND (51) ND (47) ND (47) ND (44) ND (48) ND (50) ND (44) ND (52) ND (51) ND (47) ND (47) ND (44) ND (48) ND (50) ND (44) ND (52) ND (51) ND (47) ND (47) ND (44) ND (48)

38 J ND (44) 43 J 83 ND (47) 19 J ND (44) ND (48) ND (50) ND (44) ND (52) ND (51) ND (47) ND (47) ND (44) ND (48) ND (50) ND (44) ND (52) ND (51) ND (47) 23 J ND (44) ND (48)

38 J 0 43 J 83 0 42 J 0 0

13968-32-T91.xls

Page 253: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 162 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1124 1125 1126 1127 1128 1129 1129 1130S-00-022602-CH-1124 S-00-022602-CH-1125 S-00-022602-CH-1126 S-00-022602-CH-1127 S-00-022602-CH-1128 S-00-022602-CH-1129 S-00-022602-CH-1129A S-00-022602-CH-1130

2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (44) ND (53) ND (50) ND (69) ND (54) ND (51) ND (53) ND (46) ND (44) ND (53) ND (50) ND (69) ND (54) ND (51) ND (53) ND (46) ND (44) ND (53) ND (50) ND (69) ND (54) ND (51) ND (53) ND (46) ND (44) ND (53) ND (50) ND (69) ND (54) ND (51) ND (53) ND (46) ND (44) ND (53) ND (50) 120 44 J ND (51) 25 JND (46) ND (44) ND (53) ND (50) ND (69) ND (54) ND (51) ND (53) ND (46) ND (44) ND (53) ND (50) 30 J 15 J ND (51) ND (53)

0 0 0 0 150 J 59 J 0 25 J

13968-32-T91.xls

Page 254: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 163 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1131 1132 1133 1134 1135 1136 1137 1137S-00-022602-JW-1131 S-00-022602-CH-1132 S-00-022602-CH-1133 S-00-022602-CH-1134 S-00-022602-CH-1135 S-00-022602-GS-1136 S-00-022602-GS-1137 S-00-022602-GS-1137A

2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61) ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61) ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61) ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61) ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61) ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61) ND (50) ND (48) ND (49) ND (47) ND (51) ND (48) ND (56) ND (61)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 255: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 164 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1138 1139 1140 1141 1142 1143 1144 1145S-00-022602-GS-1138 S-00-022602-GS-1139 S-00-022602-GS-1140 S-00-022602-GS-1141 S-00-022602-GS-1142 S-00-022602-GS-1143 S-00-022602-GS-1144 S-00-022602-CH-1145

2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002 2/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (48) ND (50) ND (50) ND (51) ND (48) ND (53) ND (52) ND (47) ND (48) ND (50) ND (50) ND (51) ND (48) ND (53) ND (52) ND (47) ND (48) ND (50) ND (50) ND (51) ND (48) ND (53) ND (52) ND (47) ND (48) ND (50) ND (50) ND (51) ND (48) ND (53) ND (52) ND (47) ND (48) ND (50) ND (50) 20 J ND (48) ND (53) ND (52) ND (47) ND (48) ND (50) 99 ND (51) ND (48) ND (53) ND (52) 80 ND (48) ND (50) ND (50) ND (51) ND (48) ND (53) ND (52) ND (47)

0 0 99 20 J 0 0 0 80

13968-32-T91.xls

Page 256: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 165 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1154_POOL 1154_POOL 1155_POOL 1156 1157 1158 1158 1159S-40-022702-MD-1154 S-40-022702-MD-1154A S-40-022702-MD-1155 S-37-022802-JW-1156 S-37-022802-JW-1157 S-37-022802-JW-1158 S-37-022802-JW-1158A S-00-030402-GS-1159

2/27/2002 2/27/2002 2/27/2002 2/28/2002 2/28/2002 2/28/2002 2/28/2002 3/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (45) ND (44) ND (53) ND (46) ND (53) ND (43) ND (43) ND (43) ND (45) ND (44) ND (53) ND (46) ND (53) ND (43) ND (43) ND (43) ND (45) ND (44) ND (53) ND (46) ND (53) ND (43) ND (43) ND (43) ND (45) ND (44) ND (53) ND (46) ND (53) ND (43) ND (43) ND (43) ND (45) ND (44) ND (53) ND (46) 9.7 J ND (43) ND (43) 120 ND (45) ND (44) ND (53) ND (46) ND (53) ND (43) ND (43) ND (43) ND (45) ND (44) ND (53) ND (46) ND (53) ND (43) ND (43) 34 J

0 0 0 0 9.7 J 0 0 154 J

13968-32-T91.xls

Page 257: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 166 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1160 1163 1164 1164 1167 1168 1171 1172S-00-030402-GS-1160 S-00-030402-GS-1163 S-00-030402-GS-1164 S-00-030402-GS-1164A S-00-030402-GS-1167 S-00-030402-GS-1168 S-00-030402-GS-1171 S-00-030402-GS-1172

3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (37) ND (210) ND (43) ND (42) ND (45) ND (53) ND (46) ND (44) ND (37) ND (210) ND (43) ND (42) ND (45) ND (53) ND (46) ND (44) ND (37) ND (210) ND (43) ND (42) ND (45) ND (53) ND (46) ND (44) ND (37) ND (210) ND (43) ND (42) ND (45) ND (53) ND (46) ND (44)

38 1900 20 J 19 J 120 ND (53) 89 470 ND (37) ND (210) ND (43) ND (42) ND (45) ND (53) ND (46) ND (44)

30 J 440 ND (43) ND (42) ND (45) ND (53) 24 J 140

68 J 2,340 20 J 19 J 120 0 113 J 610

13968-32-T91.xls

Page 258: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 167 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1175 1176 1179 1180 1180 1181 1184 1184S-00-030402-GS-1175 S-00-030402-GS-1176 S-00-030402-GS-1179 S-00-030402-GS-1180 S-00-030402-GS-1180A S-00-030402-GS-1181 S-00-030402-LM-1184 S-00-030402-LM-1184A

3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (45) ND (48) ND (100) ND (48) ND (47) ND (65) ND (45) ND (44) ND (45) ND (48) ND (100) ND (48) ND (47) ND (65) ND (45) ND (44) ND (45) ND (48) ND (100) ND (48) ND (47) ND (65) ND (45) ND (44) ND (45) ND (48) ND (100) ND (48) ND (47) ND (65) ND (45) ND (44)

27 J 20 J 1400 18 J ND (47) ND (65) ND (45) ND (44) ND (45) ND (48) ND (100) ND (48) ND (47) ND (65) ND (45) ND (44) ND (45) ND (48) 150 ND (48) ND (47) ND (65) ND (45) ND (44)

27 J 20 J 1,550 18 J 0 0 0 0

13968-32-T91.xls

Page 259: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 168 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1185 1186 1187 1188 1189 1190 1191 1191S-00-030402-LM-1185 S-00-030402-LM-1186 S-00-030402-LM-1187 S-00-030402-LM-1188 S-00-030402-LM-1189 S-00-030402-LM-1190 S-00-030502-GS-1191 S-00-030502-GS-1191A

3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/4/2002 3/5/2002 3/5/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) ND (42) ND (46) ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) ND (42) ND (46) ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) ND (42) ND (46) ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) ND (42) ND (46) ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) 21 J 59 ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) ND (42) ND (46) ND (47) ND (41) ND (45) ND (47) ND (48) ND (46) ND (42) 16 J

0 0 0 0 0 0 21 J 75 J

13968-32-T91.xls

Page 260: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 169 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1192 1195 1196 1199 1199 1200 1201 1202S-00-030502-GS-1192 S-00-030502-GS-1195 S-00-030502-GS-1196 S-00-030502-JW-1199 S-00-030502-JW-1199A S-00-030502-JW-1200 S-00-030502-JW-1201 S-00-030502-JW-1202

3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (49) ND (51) ND (42) ND (41) ND (230) ND (48) ND (45) ND (46) ND (49) ND (51) ND (42) ND (41) ND (230) ND (48) ND (45) ND (46) ND (49) ND (51) ND (42) ND (41) ND (230) ND (48) ND (45) ND (46) ND (49) ND (51) ND (42) ND (41) ND (230) ND (48) ND (45)

410 120 320 240 390 4300 52 170 ND (46) ND (49) ND (51) ND (42) ND (41) ND (230) ND (48) ND (45)

67 23 J 71 ND (42) ND (41) ND (230) ND (48) ND (45)

477 143 J 391 240 390 4,300 52 170

13968-32-T91.xls

Page 261: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 170 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1203 1204 1205 1206 1207 1208 1209 1209S-00-030502-JW-1203 S-00-030502-JW-1204 S-02-030502-JW-1205 S-02-030502-JW-1206 S-02-030502-JW-1207 S-02-030502-JW-1208 S-02-030502-JW-1209 S-02-030502-JW-1209A

3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002 3/5/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.5) (0.5-0.83)

ND (44) ND (45) ND (1000) ND (230) ND (49) ND (47) ND (51) ND (42) ND (44) ND (45) ND (1000) ND (230) ND (49) ND (47) ND (51) ND (42) ND (44) ND (45) ND (1000) ND (230) ND (49) ND (47) ND (51) ND (42) ND (44) ND (45) ND (1000) ND (230) ND (49) ND (47) ND (51) ND (42) ND (44) ND (45) 10000 1200 ND (49) ND (47) 16 J ND (42) ND (44) ND (45) ND (1000) ND (230) ND (49) ND (47) ND (51) ND (42) ND (44) ND (45) 1300 170 J ND (49) ND (47) ND (51) ND (42)

0 0 11,300 1,370 J 0 0 16 J 0

13968-32-T91.xls

Page 262: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 171 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1210 1210 1211 1214 1215 1215 1219 1219S-00-030502-LM-1210 S-00-030502-LM-1210A S-00-030502-LM-1211 S-00-030602-JW-1214 S-00-030602-JW-1215 S-00-030602-JW-1215A S-00-030602-GS-1219 S-00-030602-GS-1219A

3/5/2002 3/5/2002 3/5/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate Duplicate

ND (84) ND (68) ND (68) ND (45) ND (47) ND (42) ND (56) ND (110) ND (84) ND (68) ND (68) ND (45) ND (47) ND (42) ND (56) ND (110) ND (84) ND (68) ND (68) ND (45) ND (47) ND (42) ND (56) ND (110) ND (84) ND (68) ND (68) ND (45) ND (47) ND (42) ND (56) ND (110)

56 J 80 110 ND (45) ND (47) ND (42) 570 660 ND (84) ND (68) ND (68) ND (45) ND (47) ND (42) ND (56) ND (110)

23 J 38 J 35 J ND (45) ND (47) ND (42) UJ ND (56) ND (110)

79 J 118 J 145 J 0 0 0 570 660

13968-32-T91.xls

Page 263: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 172 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1220 1221 1222 1224 1225 1226 1227 1229S-00-030602-GS-1220 S-00-030602-JW-1221 S-00-030602-JW-1222 S-00-030602-JW-1224 S-00-030602-JW-1225 S-00-030602-JW-1226 S-00-030602-JW-1227 S-00-030602-JW-1229A

3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (49) ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42) ND (49) ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42) ND (49) ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42) ND (49) ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42)

19 J ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42) ND (49) ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42) ND (49) ND (46) ND (47) ND (49) ND (46) ND (46) ND (46) ND (42)

19 J 0 0 0 0 0 0 0

13968-32-T91.xls

Page 264: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 173 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1229 1230 1231 1232 1233 1234 1235 1236S-00-030602-JW-1229 S-00-030602-JW-1230 S-00-030602-MD-1231 S-00-030602-MD-1232 S-00-030602-MD-1233 S-00-030602-MD-1234 S-00-030602-JW-1235 S-00-030602-JW-1236

3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002 3/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (41) ND (44) ND (42) ND (43) ND (42) ND (43) ND (46) ND (46) ND (41) ND (44) ND (42) ND (43) ND (42) ND (43) ND (46) ND (46) ND (41) ND (44) ND (42) ND (43) ND (42) ND (43) ND (46) ND (46)

25 J 28 J ND (42) ND (43) ND (42) ND (43) ND (46) ND (46) ND (41) ND (44) ND (42) 7.1 J 7.8 J ND (43) ND (46) 20 JND (41) ND (44) ND (42) ND (43) ND (42) ND (43) 78 ND (46) ND (41) ND (44) ND (42) ND (43) ND (42) ND (43) ND (46) ND (46)

25 J 28 J 0 7.1 J 7.8 J 0 78 20 J

13968-32-T91.xls

Page 265: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 174 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1237 1238 1239 1239 1240 1241 1242 1243S-00-030602-JW-1237 S-00-030602-JW-1238 S-00-030702-MD-1239 S-00-030702-MD-1239A S-00-030702-MD-1240 S-00-030702-MD-1241 S-00-030702-MD-1242 S-00-030702-MD-1243

3/6/2002 3/6/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46) ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46) ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46) ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46) ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46) ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46) ND (46) ND (46) ND (45) ND (49) ND (45) ND (48) ND (48) ND (46)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 266: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 175 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1244 1245 1246 1247 1248 1248 1249 1253S-00-030702-MD-1244 S-00-030702-MD-1245 S-00-030702-MD-1246 S-00-030702-MD-1247 S-00-030702-GS-1248 S-00-030702-GS-1248A S-00-030702-GS-1249 S-00-030702-GS-1253

3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (45) ND (47) ND (46) ND (44) ND (45) ND (48) ND (45) ND (46) ND (45) ND (47) ND (46) ND (44) ND (45) ND (48) ND (45) ND (46) ND (45) ND (47) ND (46) ND (44) ND (45) ND (48) ND (45) ND (46) ND (45) ND (47) ND (46) ND (44) ND (45) ND (48) ND (45) ND (46) ND (45) ND (47) ND (46) 180 91 51 200 ND (46) ND (45) ND (47) ND (46) ND (44) ND (45) ND (48) ND (45) ND (46) ND (45) ND (47) ND (46) 26 J ND (45) ND (48) 40 J

0 0 0 0 206 J 91 51 240 J

13968-32-T91.xls

Page 267: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 176 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1254 1257 1258 1259 1260 1261 1261 1262S-00-030702-GS-1254 S-00-030702-LM-1257 S-00-030702-LM-1258 S-00-030702-LM-1259 S-00-030702-LM-1260 S-00-030702-MD-1261 S-00-030702-MD-1261A S-00-030702-MD-1262

3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (45) ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50) ND (45) ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50) ND (45) ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50) ND (45) ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50)

190 ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50) ND (45) ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50)

44 J ND (45) ND (44) ND (45) ND (44) ND (46) ND (46) ND (50)

234 J 0 0 0 0 0 0 0

13968-32-T91.xls

Page 268: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 177 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1262 1263 1264 1265 1265 1266 1267 1267S-00-030702-JW-1262A S-00-030702-MD-1263 S-00-030702-MD-1264 S-00-030702-JW-1265 S-00-030702-JW-1265A S-00-030702-MD-1266 S-00-030802-JW-1267 S-00-030802-JW-1267A

3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/7/2002 3/8/2002 3/8/2002(0.33-2) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) ND (220) ND (88) ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) ND (220) ND (88) ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) ND (220) ND (88) ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) ND (220) ND (88) ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) 1700 830 ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) ND (220) ND (88) ND (49) ND (44) ND (43) ND (48) ND (49) ND (47) 330 230

0 0 0 0 0 0 2,030 1,060

13968-32-T91.xls

Page 269: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 178 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1268 1269 1270 1271 1272 1273 1274 1275S-00-030802-JW-1268 S-00-030802-JW-1269 S-00-030802-JW-1270 S-00-030802-JW-1271 S-00-030802-JW-1272 S-00-030802-JW-1273 S-00-030802-JW-1274 S-00-030802-JW-1275

3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (930) ND (190) ND (83) ND (46000) ND (9500) ND (54000) ND (42) ND (840) ND (930) ND (190) ND (83) ND (46000) ND (9500) ND (54000) ND (42) ND (840) ND (930) ND (190) ND (83) ND (46000) ND (9500) ND (54000) ND (42) ND (840)

ND (930) UJ ND (190) ND (83) ND (46000) UJ 89000 ND (54000) ND (42) ND (840) 6100 2600 810 220000 ND (9500) 920000 270 11000

ND (930) ND (190) ND (83) ND (46000) ND (9500) ND (54000) ND (42) ND (840) 2500 260 70 J ND (46000) ND (9500) 41000 J 40 J 1500

8,600 2,860 880 J 220,000 89,000 961,000 J 310 J 12,500

13968-32-T91.xls

Page 270: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 179 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1276 1277 1277 1278 1279 1280 1281 1282S-00-030802-JW-1276 S-00-030802-JW-1277 S-00-030802-JW-1277A S-00-030802-JW-1278 S-00-030802-JW-1279 S-00-030802-JW-1280 S-00-030802-LM-1281 S-00-030802-LM-1282

3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002 3/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (420) ND (23000) ND (24000) ND (39) ND (44) ND (49) ND (43) ND (45) ND (420) ND (23000) ND (24000) ND (39) ND (44) ND (49) ND (43) ND (45) ND (420) ND (23000) ND (24000) ND (39) ND (44) ND (49) ND (43) ND (45) ND (420) ND (23000) UJ ND (24000) UJ ND (39) ND (44) ND (49) ND (43) ND (45)

3000 92000 210000 71 ND (44) 43 J ND (43) U ND (45) UND (420) ND (23000) ND (24000) ND (39) 65 ND (49) ND (43) ND (45)

530 11000 J 21000 J 24 J ND (44) 18 J ND (43) ND (45)

3,530 103,000 J 231,000 J 95 J 65 61 J 0 0

13968-32-T91.xls

Page 271: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 180 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1283 1284 1285 1285 1285 1286 1286 1287S-00-030802-LM-1283 S-00-030802-LM-1284 S-00-031102-JW-1285 S-00-031102-JW-1285A S-00-031102-JW-1285B S-00-031102-JW-1286 S-00-031102-JW-1286A S-00-031102-JW-1287

3/8/2002 3/8/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-2) (0-0.33) (0.33-2) (0-0.33)

Duplicate

ND (42) ND (42) ND (230) ND (220) ND (4500) ND (500) ND (43) ND (6600) ND (42) ND (42) ND (230) ND (220) ND (4500) ND (500) ND (43) ND (6600) ND (42) ND (42) ND (230) ND (220) ND (4500) ND (500) ND (43) ND (6600) ND (42) ND (42) ND (230) ND (220) ND (4500) ND (500) 49 ND (6600) ND (42) ND (42) 860 1400 5000 7000 ND (43) 89000 ND (42) ND (42) ND (230) ND (220) ND (4500) ND (500) ND (43) ND (6600) ND (42) ND (42) ND (230) ND (220) ND (4500) ND (500) ND (43) 9600

0 0 860 1,400 5,000 7,000 49 98,600

13968-32-T91.xls

Page 272: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 181 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1287 1288 1288 1289 1290 1291 1292 1293S-00-031102-JW-1287A S-00-031102-LM-1288 S-00-031102-LM-1288A S-00-031102-JW-1289 S-00-031102-JW-1290 S-00-031102-GS-1291 S-00-031102-GS-1292 S-00-031102-GS-1293

3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002(0.33-2) (0-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (850) ND (9200) ND (440) ND (470) ND (90) ND (5200) ND (45) ND (47) ND (850) ND (9200) ND (440) ND (470) ND (90) ND (5200) ND (45) ND (47) ND (850) ND (9200) ND (440) ND (470) ND (90) ND (5200) ND (45) ND (47) ND (850) ND (9200) ND (440) ND (470) ND (90) ND (5200) ND (45) ND (47)

9000 99000 4500 5700 860 36000 30 J 99 ND (850) ND (9200) ND (440) ND (470) ND (90) ND (5200) ND (45) ND (47)

690 J 9100 J 410 J 510 86 J 3900 J ND (45) ND (47)

9,690 J 108,100 J 4,910 J 6,210 946 J 39,900 J 30 J 99

13968-32-T91.xls

Page 273: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 182 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1293 1294 1295 1296 1297 1298 1299 1301S-00-031102-GS-1293A S-00-031102-JW-1294 S-00-031102-JW-1295 S-00-031102-GS-1296 S-00-031102-GS-1297 S-00-031102-JW-1298 S-00-031102-GS-1299 S-13-012402-JW-1301

3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 1/24/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-0.526)

Duplicate

ND (52) ND (46) ND (2300) ND (44) ND (51) ND (250) ND (47) ND (430) ND (52) ND (46) ND (2300) ND (44) ND (51) ND (250) ND (47) ND (430) ND (52) ND (46) ND (2300) ND (44) ND (51) ND (250) ND (47) ND (430) ND (52) ND (46) ND (2300) ND (44) ND (51) ND (250) ND (47) ND (430)

63 ND (46) 39000 ND (44) ND (51) ND (250) 46 J 1500 ND (52) 50 ND (2300) 230 370 1200 ND (47) ND (430) ND (52) ND (46) 3200 ND (44) ND (51) ND (250) 23 J 130 J

63 50 42,200 230 370 1,200 69 J 1,630 J

13968-32-T91.xls

Page 274: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 183 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1301 1308 1308 1311 1311 1312 1313 1314S-13-012402-JW-1301A S-13-012402-MA-1308 S-13-012402-MA-1308A S-13-012402-MA-1311 S-13-012402-MA-1311A S-13-012402-MA-1312 S-13-012402-JW-1313 S-13-012402-MA-1314

1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002 1/24/2002(0.526-1.583) (0.083-0.33) (0.33-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (42) ND (41) ND (42) ND (44) ND (44) ND (210) ND (44) ND (43) ND (42) ND (41) ND (42) ND (44) ND (44) ND (210) ND (44) ND (43) ND (42) ND (41) ND (42) ND (44) ND (44) ND (210) ND (44) ND (43) ND (42) ND (41) ND (42) ND (44) 27 J ND (210) ND (44) ND (43)

13 J 110 ND (42) 22 J ND (44) 900 280 ND (43) ND (42) ND (41) ND (42) ND (44) ND (44) ND (210) ND (44) ND (43) ND (42) ND (41) ND (42) ND (44) ND (44) ND (210) 41 J ND (43)

13 J 110 0 22 J 27 J 900 321 J 0

13968-32-T91.xls

Page 275: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 184 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1400 1401 1402 1403 1403 1404 1405 1406S-00-031102-JW-1400 S-00-031102-JW-1401 S-00-031102-JW-1402 S-00-031102-GS-1403 S-00-031102-JW-1403A S-00-031102-JW-1404 S-00-031102-GS-1405 S-00-031102-GS-1406

3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002 3/11/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (87) ND (46) ND (290) ND (50) ND (45) ND (44) ND (44) ND (52) ND (87) ND (46) ND (290) ND (50) ND (45) ND (44) ND (44) ND (52) ND (87) ND (46) ND (290) ND (50) ND (45) ND (44) ND (44) ND (52) ND (87) ND (46) ND (290) ND (50) ND (45) ND (44) ND (44) ND (52) ND (87) ND (46) ND (290) ND (50) ND (45) 220 ND (44) ND (52)

1200 96 1200 130 110 ND (44) 250 170 ND (87) ND (46) ND (290) ND (50) ND (45) 57 ND (44) ND (52)

1,200 96 1,200 130 110 277 250 170

13968-32-T91.xls

Page 276: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 185 of 314

Sample Location: 1407 1408 1408 1409 1410 1411 1412 1412Sample ID: S-00-031102-GS-1407 S-00-031202-GS-1408 S-00-031202-GS-1408A S-00-031202-GS-1409 S-00-031202-GS-1410 S-00-031202-GS-1411 S-00-031302-GS-1412 S-00-031302-GS-1412ASample Date: 3/11/2002 3/12/2002 3/12/2002 3/12/2002 3/12/2002 3/12/2002 3/13/2002 3/13/2002Sample Depth: (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) ND (41) ND (42) Aroclor-1221 (PCB-1221) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) ND (41) ND (42) Aroclor-1232 (PCB-1232) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) ND (41) ND (42) Aroclor-1242 (PCB-1242) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) ND (41) ND (42) Aroclor-1248 (PCB-1248) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) 33 J 32 JAroclor-1254 (PCB-1254) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) ND (41) ND (42) Aroclor-1260 (PCB-1260) ug/Kg ND (48) ND (43) ND (43) ND (47) ND (45) ND (45) ND (41) ND (42)

Sum of Detected PCBs (ND=0) ug/Kg 0 0 0 0 0 0 33 J 32 J

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 277: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 186 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1413 1414 1415 1416 1417 1418 1419 1420S-00-031302-GS-1413 S-00-031302-GS-1414 S-00-031302-GS-1415 S-00-031302-GS-1416 S-00-031302-GS-1417 S-00-031302-GS-1418 S-00-031302-GS-1419 S-00-031302-LM-1420

3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/13/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (54) ND (47) ND (43) ND (50) ND (47) ND (47) ND (46) ND (48) ND (54) ND (47) ND (43) ND (50) ND (47) ND (47) ND (46) ND (48) ND (54) ND (47) ND (43) ND (50) ND (47) ND (47) ND (46) ND (48) ND (54) ND (47) ND (43) ND (50) ND (47) ND (47) ND (46) ND (48)

210 150 ND (43) ND (50) 55 110 21 J 63 ND (54) ND (47) ND (43) ND (50) ND (47) ND (47) ND (46) ND (48) ND (54) ND (47) ND (43) ND (50) ND (47) ND (47) 11 J ND (48)

210 150 0 0 55 110 32 J 63

13968-32-T91.xls

Page 278: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 187 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1421 1422 1423 1424 1425 1425 1434 1435S-00-031302-LM-1421 S-00-031302-GS-1422 S-00-031302-GS-1423 S-00-031302-GS-1424 S-00-031302-GS-1425 S-00-031302-GS-1425A S-00-031802-JW-1434 S-00-031802-JW-1435

3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/13/2002 3/18/2002 3/18/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (50) ND (46) ND (44) ND (49) ND (46) ND (45) ND (850) ND (45) ND (50) ND (46) ND (44) ND (49) ND (46) ND (45) ND (850) ND (45) ND (50) ND (46) ND (44) ND (49) ND (46) ND (45) ND (850) ND (45) ND (50) ND (46) ND (44) ND (49) ND (46) ND (45) ND (850) ND (45)

75 170 ND (44) 140 140 130 15000 ND (45) ND (50) ND (46) ND (44) ND (49) ND (46) ND (45) ND (850) 170

13 J 24 J ND (44) ND (49) 32 J 31 J 1100 ND (45)

88 J 194 J 0 140 172 J 161 J 16,100 170

13968-32-T91.xls

Page 279: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 188 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1436 1437 1438 1438 1439 1440 1441 1442S-00-031802-JW-1436 S-00-031802-JW-1437 S-00-031802-JW-1438 S-00-031802-JW-1438A S-00-031802-JW-1439 S-00-031802-JW-1440 S-00-031802-JW-1441 S-00-031802-JW-1442

3/18/2002 3/18/2002 3/18/2002 3/18/2002 3/18/2002 3/18/2002 3/18/2002 3/18/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (49) ND (51) ND (48) ND (91) ND (47) ND (49) ND (43) ND (44) ND (49) ND (51) ND (48) ND (91) ND (47) ND (49) ND (43) ND (44) ND (49) ND (51) ND (48) ND (91) ND (47) ND (49) ND (43) ND (44) ND (49) ND (51) ND (48) ND (91) ND (47) ND (49) ND (43) ND (44) ND (49) ND (51) ND (48) 870 ND (47) ND (49) 170 ND (44) ND (49) ND (51) ND (48) ND (91) ND (47) ND (49) ND (43) ND (44) ND (49) ND (51) ND (48) 120 ND (47) ND (49) 42 J

0 0 0 0 990 0 0 212 J

13968-32-T91.xls

Page 280: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 189 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1443 1446 1447 1450 1451 1451 1454 1454S-00-031802-JW-1443 S-00-031802-JW-1446 S-00-031802-JW-1447 S-00-031902-JW-1450 S-00-031902-JW-1451 S-00-031902-JW-1451A S-00-032002-JW-1454 S-00-032002-JW-1454A

3/18/2002 3/18/2002 3/18/2002 3/19/2002 3/19/2002 3/19/2002 3/20/2002 3/20/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (46) ND (45) ND (45) ND (47) ND (50) ND (45) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (50) ND (45) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (50) ND (45) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (50) ND (45) ND (44) ND (44)

16 J 35 J 52 ND (47) ND (50) ND (45) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (50) ND (45) ND (44) ND (44) ND (46) 11 J 14 J ND (47) ND (50) ND (45) ND (44) ND (44)

16 J 46 J 66 J 0 0 0 0 0

13968-32-T91.xls

Page 281: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 190 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1455 1456 1457 1458 1460 1460 1461 1462S-00-032002-JW-1455 S-00-032002-JW-1456 S-00-032002-JW-1457 S-00-032002-JW-1458 S-00-032102-LM-1460 S-00-032102-LM-1460A S-00-032102-LM-1461 S-00-032102-LM-1462

3/20/2002 3/20/2002 3/20/2002 3/20/2002 3/21/2002 3/21/2002 3/21/2002 3/21/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (43) ND (46) ND (47) ND (43) ND (41) ND (42) ND (42) ND (44) ND (43) ND (46) ND (47) ND (43) ND (41) ND (42) ND (42) ND (44) ND (43) ND (46) ND (47) ND (43) ND (41) ND (42) ND (42) ND (44) ND (43) 33 J 110 ND (43) ND (41) ND (42) ND (42) ND (44) ND (43) ND (46) ND (47) ND (43) 8.1 J 6.5 J 7.5 JND (44) ND (43) ND (46) ND (47) ND (43) ND (41) ND (42) ND (42) ND (44) ND (43) ND (46) 32 J ND (43) ND (41) ND (42) ND (42)

0 0 33 J 142 J 0 8.1 J 6.5 J 7.5 J

13968-32-T91.xls

Page 282: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 191 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1463 1464 1465 1466 1467 1470 1470 1471S-00-032102-LM-1463 S-00-032102-LM-1464 S-00-032102-LM-1465 S-00-032102-LM-1466 S-00-032102-LM-1467 S-27-032202-JW-1470A S-27-032202-JW-1470 S-27-032202-JW-1471

3/21/2002 3/21/2002 3/21/2002 3/21/2002 3/21/2002 3/22/2002 3/22/2002 3/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (46) ND (47) ND (43) ND (49) ND (42) ND (42) ND (42) ND (44) ND (46) ND (47) ND (43) ND (49) ND (42) ND (42) ND (42) ND (44) ND (46) ND (47) ND (43) ND (49) ND (42) ND (42) ND (42) ND (44) ND (46) ND (47) ND (43) ND (49) ND (42) ND (42) ND (42) ND (44) ND (46) ND (47) ND (43) ND (49) 10 J ND (42) ND (42) ND (44) ND (46) ND (47) ND (43) ND (49) ND (42) ND (42) ND (42) ND (44) ND (46) ND (47) ND (43) ND (49) ND (42) ND (42) ND (42)

0 0 0 0 0 10 J 0 0

13968-32-T91.xls

Page 283: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 192 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1472 1473 1474 1475 1476 1477 1478 1479S-27-032202-JW-1472 S-27-032202-JW-1473 S-27-032202-JW-1474 S-27-032202-JW-1475 S-27-032202-JW-1476 S-27-032202-JW-1477 S-27-032202-JW-1478 S-27-032202-JW-1479

3/22/2002 3/22/2002 3/22/2002 3/22/2002 3/22/2002 3/22/2002 3/22/2002 3/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44) ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44) ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44) ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44) ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44) ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44) ND (45) ND (52) ND (47) ND (51) ND (49) ND (48) ND (50) ND (44)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 284: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 193 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1480 1480 1481 1482 1483 1484 1485 1485S-27-032502-JW-1480 S-27-032502-JW-1480A S-27-032502-GS-1481 S-27-032502-JW-1482 S-27-032502-JW-1483 S-27-032502-JW-1484 S-00-032502-GS-1485 S-00-032502-GS-1485A

3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (49) ND (48) ND (880) ND (51) ND (46) ND (46) ND (46) ND (47) ND (49) ND (48) ND (880) ND (51) ND (46) ND (46) ND (46) ND (47) ND (49) ND (48) ND (880) ND (51) ND (46) ND (46) ND (46) ND (47) ND (49) ND (48) ND (880) ND (51) ND (46) ND (46) ND (46) ND (47) ND (49) ND (48) ND (880) ND (51) ND (46) ND (46) ND (46) 19 JND (49) 31 J 9700 ND (51) ND (46) ND (46) ND (46) ND (47) ND (49) ND (48) ND (880) ND (51) ND (46) ND (46) ND (46) ND (47)

0 31 J 9,700 0 0 0 0 19 J

13968-32-T91.xls

Page 285: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 194 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1486 1487 1488 1489 1490 1491 1492 1493S-00-032502-JW-1486 S-00-032502-JW-1487 S-00-032502-JW-1488 S-00-032502-GS-1489 S-00-032502-GS-1490 S-00-032502-JW-1491 S-00-032502-GS-1492 S-00-032502-GS-1493

3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (47) ND (100) ND (44) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (100) ND (44) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (100) ND (44) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) ND (100) ND (44) ND (44) ND (44) ND (46) ND (45) ND (45)

12 J 1200 110 150 ND (44) ND (46) ND (45) ND (45) ND (47) ND (100) ND (44) ND (44) ND (44) ND (46) ND (45) ND (45) ND (47) 260 38 J 37 J ND (44) ND (46) ND (45) ND (45)

12 J 1,460 148 J 187 J 0 0 0 0

13968-32-T91.xls

Page 286: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 195 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1494 1495 1496 1497 1498 1499 1500 1500S-00-032502-JW-1494 S-00-032502-GS-1495 S-00-032502-GS-1496 S-00-032502-GS-1497 S-00-032502-GS-1498 S-00-032602-GS-1499 S-00-032602-GS-1500 S-00-032602-GS-1500A

3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/25/2002 3/26/2002 3/26/2002 3/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (45) ND (48) ND (48) ND (46) ND (48) ND (45) ND (44) ND (44) ND (45) ND (48) ND (48) ND (46) ND (48) ND (45) ND (44) ND (44) ND (45) ND (48) ND (48) ND (46) ND (48) ND (45) ND (44) ND (44) ND (45) ND (48) ND (48) ND (46) ND (48) ND (45) ND (44) ND (44) ND (45) ND (48) ND (48) 47 26 J ND (45) ND (44) ND (44) ND (45) ND (48) ND (48) ND (46) ND (48) ND (45) ND (44) ND (44) ND (45) ND (48) ND (48) 39 J 22 J ND (45) ND (44) ND (44)

0 0 0 86 J 48 J 0 0 0

13968-32-T91.xls

Page 287: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 196 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1501 1502 1503 1504 1505 1506 1507 1508S-00-032602-GS-1501 S-00-032602-GS-1502 S-00-032602-GS-1503 S-00-032602-GS-1504 S-00-032602-GS-1505 S-00-032602-GS-1506 S-00-032602-GS-1507 S-00-032602-GS-1508

3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (44) ND (87) ND (980) ND (47) ND (48) ND (44) ND (46) ND (45) ND (44) ND (87) ND (980) ND (47) ND (48) ND (44) ND (46) ND (45) ND (44) ND (87) ND (980) ND (47) ND (48) ND (44) ND (46) ND (45) ND (44) ND (87) ND (980) ND (47) ND (48) ND (44) ND (46) ND (45) ND (44) 1100 8800 31 J ND (48) 170 500 230 ND (44) ND (87) ND (980) ND (47) ND (48) ND (44) ND (46) ND (45) ND (44) 480 1700 ND (47) ND (48) 170 220 62

0 1,580 10,500 31 J 0 340 720 292

13968-32-T91.xls

Page 288: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 197 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1509 1509 1510 1511 1512 1513 1514 1515S-00-032602-GS-1509 S-00-032602-GS-1509A S-00-032602-GS-1510 S-00-032602-GS-1511 S-00-032602-GS-1512 S-00-032602-GS-1513 S-00-032602-GS-1514 S-00-032602-GS-1515

3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (450) ND (220) ND (840) ND (47) ND (2200) ND (480) ND (400) ND (460) ND (450) ND (220) ND (840) ND (47) ND (2200) ND (480) ND (400) ND (460) ND (450) ND (220) ND (840) ND (47) ND (2200) ND (480) ND (400) ND (460) ND (450) ND (220) ND (840) ND (47) ND (2200) ND (480) ND (400) ND (460)

2000 1100 8200 230 14000 ND (480) 1200 3000 ND (450) ND (220) ND (840) ND (47) ND (2200) 4600 ND (400) ND (460)

310 J 200 J 2400 64 1800 J ND (480) 250 J 820

2,310 J 1,300 J 10,600 294 15,800 J 4,600 1,450 J 3,820

13968-32-T91.xls

Page 289: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 198 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1516 1517 1518 1519 1519 1520 1521 1522S-00-032602-GS-1516 S-00-032602-GS-1517 S-00-032602-GS-1518 S-00-032602-GS-1519 S-00-032602-GS-1519A S-00-032602-GS-1520 S-00-032602-GS-1521 S-00-032602-GS-1522

3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (69) ND (46) ND (47) ND (42) ND (42) ND (42) ND (44) ND (48) ND (69) ND (46) ND (47) ND (42) ND (42) ND (42) ND (44) ND (48) ND (69) ND (46) ND (47) ND (42) ND (42) ND (42) ND (44) ND (48) ND (69) ND (46) ND (47) ND (42) ND (42) ND (42) ND (44) ND (48)

770 130 ND (47) ND (42) ND (42) ND (42) ND (44) ND (48) ND (69) ND (46) ND (47) ND (42) ND (42) ND (42) ND (44) ND (48)

180 47 ND (47) ND (42) ND (42) ND (42) ND (44) ND (48)

950 177 0 0 0 0 0 0

13968-32-T91.xls

Page 290: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 199 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1523 1524 1525 1526 1527 1528 1529 1529S-00-032602-GS-1523 S-00-032602-GS-1524 S-00-032602-GS-1525 S-00-032602-GS-1526 S-05-032602-GS-1527 S-05-032602-GS-1528 S-05-032602-GS-1529 S-05-032602-GS-1529A

3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (49) ND (47) ND (44) ND (45) ND (49) ND (50) ND (46) ND (38) ND (49) ND (47) ND (44) ND (45) ND (49) ND (50) ND (46) ND (38) ND (49) ND (47) ND (44) ND (45) ND (49) ND (50) ND (46) ND (38) ND (49) ND (47) ND (44) ND (45) ND (49) ND (50) ND (46) ND (38) ND (49) ND (47) ND (44) 77 ND (49) 13 J 51 33 JND (49) ND (47) ND (44) ND (45) 360 ND (50) ND (46) ND (38) ND (49) ND (47) ND (44) 36 J ND (49) ND (50) 38 J 14 J

0 0 0 113 J 360 13 J 89 J 47 J

13968-32-T91.xls

Page 291: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 200 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1530 1531 1532 1533 1534 1535 1535 1536S-05-032602-GS-1530 S-00-032602-GS-1531 S-00-032602-GS-1532 S-00-032602-GS-1533 S-00-032602-GS-1534 S-00-032602-GS-1535 S-00-032602-GS-1535A S-00-032702-GS-1536

3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/26/2002 3/27/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (40) ND (53) ND (54) ND (230) ND (230) ND (220) ND (230) ND (48) ND (40) ND (53) ND (54) ND (230) ND (230) ND (220) ND (230) ND (48) ND (40) ND (53) ND (54) ND (230) ND (230) ND (220) ND (230) ND (48) ND (40) ND (53) ND (54) ND (230) ND (230) ND (220) ND (230) ND (48)

56 ND (53) ND (54) 1500 1400 1800 1500 ND (48) ND (40) ND (53) ND (54) ND (230) ND (230) ND (220) ND (230) ND (48)

27 J ND (53) ND (54) 170 J 130 J 130 J 110 J ND (48)

83 J 0 0 1,670 J 1,530 J 1,930 J 1,610 J 0

13968-32-T91.xls

Page 292: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 201 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1536 1537 1538 1539 1540 1541 1542 1543S-00-032702-GS-1536A S-00-032702-GS-1537 S-00-032702-GS-1538 S-00-032702-GS-1539 S-00-032702-GS-1540 S-00-032702-GS-1541 S-36-032702-GS-1542 S-36-032702-GS-1543

3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45) ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45) ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45) ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45) ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45) ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45) ND (45) ND (43) ND (46) ND (46) ND (46) ND (45) ND (43) ND (45)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 293: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 202 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1544 1545 1546 1548 1548 1550 1551 1552S-36-032702-GS-1544 S-36-032702-GS-1545 S-36-032702-GS-1546 S-36-032702-GS-1548 S-36-032702-GS-1548A S-36-032702-GS-1550 S-36-032702-GS-1551 S-36-032702-GS-1552

3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002 3/27/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44) ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44) ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44) ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44) ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44) ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44) ND (43) ND (43) ND (51) ND (48) ND (50) ND (42) ND (43) ND (44)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 294: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 203 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1553 1554 1555 1557 1557 1558 1559 1560S-36-032702-GS-1553 S-36-032702-GS-1554 S-36-032702-GS-1555 S-31-040202-JW-1557 S-31-040202-JW-1557A S-31-040202-JW-1558 S-31-040202-JW-1559 S-31-040202-JW-1560

3/27/2002 3/27/2002 3/27/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48) ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48) ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48) ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48) ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48) ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48) ND (55) ND (48) ND (52) ND (51) ND (55) ND (54) ND (49) ND (48)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 295: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 204 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1561 1562 1563 1564 1565 1566 1566 1567S-31-040202-JW-1561 S-31-040202-JW-1562 S-31-040202-JW-1563 S-31-040202-JW-1564 S-31-040202-JW-1565 S-31-040202-JW-1566 S-31-040202-JW-1566A S-31-040202-GS-1567

4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.83-1.17) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63) ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63) ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63) ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63) ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63) ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63) ND (53) ND (54) ND (49) ND (53) ND (53) ND (57) ND (62) ND (63)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 296: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 205 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1568 1569 1570 1571 1573 1574 1575 1576S-31-040202-GS-1568 S-31-040202-GS-1569 S-31-040202-GS-1570 S-31-040202-GS-1571 S-00-040202-GS-1573 S-00-040202-GS-1574 S-00-040202-GS-1575 S-00-040202-GS-1576

4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/2/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (63) ND (47) ND (65) ND (49) ND (48) ND (520) ND (40) ND (43) ND (63) ND (47) ND (65) ND (49) ND (48) ND (520) ND (40) ND (43) ND (63) ND (47) ND (65) ND (49) ND (48) ND (520) ND (40) ND (43) ND (63) ND (47) ND (65) ND (49) ND (48) ND (520) ND (40) ND (43) ND (63) ND (47) ND (65) ND (49) 13 J 1100 23 J ND (43) ND (63) ND (47) ND (65) ND (49) ND (48) ND (520) ND (40) ND (43) ND (63) ND (47) ND (65) ND (49) ND (48) ND (520) ND (40) ND (43)

0 0 0 0 13 J 1,100 23 J 0

13968-32-T91.xls

Page 297: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 206 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1576 1577 1578 1579 1580 1580 1581 1582S-00-040202-GS-1576A S-00-040202-JW-1577 S-00-040202-JW-1578 S-00-040202-JW-1579 S-03-040302-GS-1580 S-03-040302-GS-1580A S-03-040302-JW-1581 S-03-040302-GS-1582

4/2/2002 4/2/2002 4/2/2002 4/2/2002 4/3/2002 4/3/2002 4/3/2002 4/3/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (42) ND (42) ND (47) ND (42) ND (46) ND (47) ND (46) ND (46) ND (42) ND (42) ND (47) ND (42) ND (46) ND (47) ND (46) ND (46) ND (42) ND (42) ND (47) ND (42) ND (46) ND (47) ND (46) ND (46) ND (42) ND (42) ND (47) ND (42) ND (46) ND (47) ND (46) ND (46)

13 J 13 J 46 J ND (42) ND (46) ND (47) ND (46) ND (46) ND (42) ND (42) ND (47) ND (42) ND (46) ND (47) ND (46) ND (46) ND (42) ND (42) ND (47) ND (42) ND (46) ND (47) ND (46) ND (46)

13 J 13 J 46 J 0 0 0 0 0

13968-32-T91.xls

Page 298: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 207 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1583 1584 1585 1586 1587 1588 1589 1591S-03-040302-GS-1583 S-03-040302-GS-1584 S-03-040302-JW-1585 S-03-040302-GS-1586 S-03-040302-GS-1587 S-03-040302-GS-1588 S-03-040302-GS-1589 S-03-040402-GS-1591

4/3/2002 4/3/2002 4/3/2002 4/3/2002 4/3/2002 4/3/2002 4/3/2002 4/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (50) ND (43) ND (52) ND (50) ND (51) ND (49) ND (54) ND (45) ND (50) ND (43) ND (52) ND (50) ND (51) ND (49) ND (54) ND (45) ND (50) ND (43) ND (52) ND (50) ND (51) ND (49) ND (54) ND (45) ND (50) ND (43) ND (52) ND (50) ND (51) ND (49) ND (54) ND (45) ND (50) ND (43) 15 J ND (50) ND (51) 8.9 J ND (54) ND (45) ND (50) ND (43) ND (52) ND (50) ND (51) ND (49) ND (54) ND (45) ND (50) ND (43) ND (52) ND (50) ND (51) ND (49) ND (54) ND (45)

0 0 15 J 0 0 8.9 J 0 0

13968-32-T91.xls

Page 299: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 208 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1591 1592 1593 1594 1595 1596 1597 1598S-03-040402-GS-1591A S-03-040402-GS-1592 S-03-040402-GS-1593 S-03-040402-GS-1594 S-00-040402-GS-1595 S-00-040402-GS-1596 S-00-040402-GS-1597 S-00-040402-GS-1598

4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (55) ND (61) ND (47) ND (44) ND (50) ND (49) ND (47) ND (48) ND (55) ND (61) ND (47) ND (44) ND (50) ND (49) ND (47) ND (48) ND (55) ND (61) ND (47) ND (44) ND (50) ND (49) ND (47) ND (48) ND (55) ND (61) ND (47) ND (44) ND (50) ND (49) ND (47) ND (48) ND (55) ND (61) ND (47) 34 J 20 J ND (49) 13 JND (48) ND (55) ND (61) ND (47) ND (44) ND (50) ND (49) ND (47) ND (48) ND (55) ND (61) ND (47) ND (44) ND (50) ND (49) ND (47)

0 0 0 0 34 J 20 J 0 13 J

13968-32-T91.xls

Page 300: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 209 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1599 1600 1601 1601 1602 1603 1604 1605S-00-040402-GS-1599 S-00-040402-GS-1600 S-00-040402-GS-1601 S-00-040402-GS-1601A S-20-040402-GS-1602 S-20-040402-GS-1603 S-20-040402-GS-1604 S-20-040402-GS-1605

4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (94) ND (43) ND (42) ND (43) ND (44) ND (45) ND (43) ND (44) ND (94) ND (43) ND (42) ND (43) ND (44) ND (45) ND (43) ND (44) ND (94) ND (43) ND (42) ND (43) ND (44) ND (45) ND (43) ND (44) ND (94) ND (43) ND (42) ND (43) ND (44) ND (45) ND (43)

8.9 J 270 ND (43) ND (42) ND (43) ND (44) ND (45) ND (43) ND (44) ND (94) ND (43) ND (42) ND (43) UJ ND (44) UJ ND (45) UJ ND (43) ND (44) ND (94) ND (43) ND (42) ND (43) UJ ND (44) UJ ND (45) UJ ND (43)

8.9 J 270 0 0 0 0 0 0

13968-32-T91.xls

Page 301: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 210 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1606 1607 1608 1609 1609 1610 1611 1612S-00-040402-GS-1606 S-00-040402-GS-1607 S-00-040402-GS-1608 S-00-040402-GS-1609 S-00-040402-GS-1609A S-00-040402-GS-1610 S-00-040402-GS-1611 S-00-040502-JW-1612

4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/4/2002 4/5/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (45) ND (47) ND (42) ND (43) ND (43) ND (46) ND (45) ND (45) ND (45) ND (47) ND (42) ND (43) ND (43) ND (46) ND (45) ND (45) ND (45) ND (47) ND (42) ND (43) ND (43) ND (46) ND (45) ND (45) ND (45) ND (47) ND (42) ND (43) ND (43) ND (46) ND (45) ND (45) ND (45) ND (47) ND (42) ND (43) ND (43) ND (46) ND (45) ND (45) ND (45) ND (47) ND (42) ND (43) ND (43) UJ ND (46) ND (45) UJ ND (45) ND (45) ND (47) ND (42) 18 J ND (43) UJ ND (46) ND (45) UJ ND (45)

0 0 0 18 J 0 0 0 0

13968-32-T91.xls

Page 302: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 211 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1612 1613 1614 1615 1616 1617 1618 1619S-00-040502-JW-1612A S-00-040502-JW-1613 S-00-040502-JW-1614 S-00-040502-JW-1615 S-00-040502-JW-1616 S-00-040502-JW-1617 S-00-040502-JW-1618 S-00-040802-GS-1619

4/5/2002 4/5/2002 4/5/2002 4/5/2002 4/5/2002 4/5/2002 4/5/2002 4/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (46) ND (48) ND (51) ND (49) ND (47) ND (46) ND (44) ND (46) ND (46) ND (48) ND (51) ND (49) ND (47) ND (46) ND (44) ND (46) ND (46) ND (48) ND (51) ND (49) ND (47) ND (46) ND (44) ND (46) ND (46) ND (48) ND (51) ND (49) ND (47) ND (46) ND (44) ND (46) ND (46) ND (48) ND (51) ND (49) ND (47) ND (46) ND (44) ND (46) ND (46) 62 41 J ND (49) ND (47) ND (46) ND (44) ND (46) ND (46) ND (48) ND (51) ND (49) ND (47) ND (46) ND (44)

0 0 62 41 J 0 0 0 0

13968-32-T91.xls

Page 303: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 212 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1620 1621 1624 1625 1626 1627 1628 1629S-00-040802-GS-1620 S-00-040802-GS-1621 S-00-040802-GS-1624 S-00-040802-GS-1625 S-00-040802-GS-1626 S-00-040802-GS-1627 S-00-040802-GS-1628 S-00-040802-GS-1629

4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (43) ND (480) ND (52) ND (43) ND (47) ND (52) ND (470) ND (49) ND (43) ND (480) ND (52) ND (43) ND (47) ND (52) ND (470) ND (49) ND (43) ND (480) ND (52) ND (43) ND (47) ND (52) ND (470) ND (49) ND (43) ND (480) ND (52) ND (43) ND (47) ND (52) ND (470) ND (49)

39 J 2700 170 ND (43) ND (47) 370 1300 13 JND (43) ND (480) ND (52) ND (43) ND (47) ND (52) ND (470) ND (49)

19 J 500 34 J ND (43) ND (47) 88 200 J ND (49)

58 J 3,200 204 J 0 0 458 1,500 J 13 J

13968-32-T91.xls

Page 304: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 213 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1632 1632 1633 1634 1635 1635 1636 1637S-00-040802-GS-1632 S-00-040802-GS-1632A S-00-040802-GS-1633 S-00-040802-GS-1634 S-00-040802-GS-1635 S-00-040802-GS-1635A S-00-040802-GS-1636 S-00-040802-GS-1637

4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002 4/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (480) ND (430) ND (41) ND (580) ND (87) ND (210) ND (45) ND (48) ND (480) ND (430) ND (41) ND (580) ND (87) ND (210) ND (45) ND (48) ND (480) ND (430) ND (41) ND (580) ND (87) ND (210) ND (45) ND (48) ND (480) ND (430) ND (41) ND (580) ND (87) ND (210) ND (45) ND (48) ND (480) ND (430) ND (41) ND (580) ND (87) ND (210) ND (45) ND (48)

3400 2900 41 4200 900 910 120 ND (48) ND (480) ND (430) ND (41) ND (580) ND (87) ND (210) ND (45) ND (48)

3,400 2,900 41 4200 900 910 120 0

13968-32-T91.xls

Page 305: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 214 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1638 1639 1639 1639 1640 1641 1642 1643S-00-040802-GS-1638 S-19-040902-JW-1639 S-19-040902-JW-1639A S-19-040902-JW-1639B S-19-040902-JW-1640 S-19-040902-JW-1641 S-19-040902-JW-1642 S-19-040902-JW-1643

4/8/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002(0-0.33) (0-0.33) (0.33-1) (0.33-1) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47) ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47) ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47) ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47) ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47) ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47) ND (47) ND (45) ND (44) ND (43) ND (46) ND (53) ND (48) ND (47)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 306: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 215 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1644 1645 1646 1647 1648 1649 1649 1649S-39-040902-JW-1644 S-39-040902-JW-1645 S-39-040902-JW-1646 S-39-040902-JW-1647 S-39-040902-JW-1648 S-00-040902-JW-1649 S-00-040902-JW-1649A S-00-040902-JW-1649B

4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-0.67)

Duplicate

ND (42) ND (45) ND (46) ND (46) ND (47) ND (970) ND (990) ND (910) ND (42) ND (45) ND (46) ND (46) ND (47) ND (970) ND (990) ND (910) ND (42) ND (45) ND (46) ND (46) ND (47) ND (970) ND (990) ND (910) ND (42) ND (45) ND (46) ND (46) ND (47) ND (970) ND (990) ND (910) ND (42) ND (45) ND (46) ND (46) ND (47) 16000 10000 10000 ND (42) ND (45) ND (46) ND (46) ND (47) ND (970) ND (990) ND (910) ND (42) ND (45) ND (46) ND (46) ND (47) 1500 850 J 850 J

0 0 0 0 0 17,500 10,850 J 10,850 J

13968-32-T91.xls

Page 307: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 216 of 314

Sample Location: 1649 1650 1650 1650 1651 1651 1652 1652Sample ID: S-00-040902-JW-1649C S-00-040902-GS-1650 S-00-040902-GS-1650A S-00-040902-GS-1650B S-00-040902-JW-1651 S-00-040902-JW-1651A S-00-040902-GS-1652 S-00-040902-GS-1652ASample Date: 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002Sample Depth: (0.67-1) (0-0.33) (0.33-0.67) (0.67-1) (0-0.33) (0.33-0.67) (0-0.33) (0.33-0.67)

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (87) ND (230) ND (52) ND (53) ND (990000) ND (55000) ND (990) ND (55000) Aroclor-1221 (PCB-1221) ug/Kg ND (87) ND (230) ND (52) ND (53) ND (990000) ND (55000) ND (990) ND (55000) Aroclor-1232 (PCB-1232) ug/Kg ND (87) ND (230) ND (52) ND (53) ND (990000) ND (55000) ND (990) ND (55000) Aroclor-1242 (PCB-1242) ug/Kg ND (87) ND (230) ND (52) ND (53) ND (990000) ND (55000) ND (990) 330000 Aroclor-1248 (PCB-1248) ug/Kg 590 710 150 180 9900000 860000 16000 ND (55000) Aroclor-1254 (PCB-1254) ug/Kg ND (87) ND (230) ND (52) ND (53) ND (990000) ND (55000) ND (990) ND (55000) Aroclor-1260 (PCB-1260) ug/Kg 38 J 100 J 22 J 25 J ND (990000) ND (55000) 1200 ND (55000)

Sum of Detected PCBs (ND=0) ug/Kg 628 J 810 J 172 J 205 J 9,900,000 860,000 17,200 330,000

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 308: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 217 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1653 1653 1653 1653 1653 1654 1654 1655S-00-040902-JW-1653 S-00-040902-JW-1653A S-00-040902-JW-1653B S-00-040902-JW-1653C S-00-040902-JW-1653D S-00-040902-GS-1654 S-00-040902-GS-1654A S-00-041002-GS-1655

4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/9/2002 4/10/2002(0-0.33) (0-0.33) (0.33-0.67) (0.67-1) (1-1.33) (0-0.33) (0.33-0.5) (0-0.33)

Duplicate

ND (250) ND (230) ND (530) ND (210) ND (2100) ND (11000) ND (18000) ND (42) ND (250) ND (230) ND (530) ND (210) ND (2100) ND (11000) ND (18000) ND (42) ND (250) ND (230) ND (530) ND (210) ND (2100) ND (11000) ND (18000) ND (42) ND (250) ND (230) ND (530) ND (210) ND (2100) ND (11000) ND (18000) ND (42)

1000 1500 5900 820 20000 99000 150000 ND (42) ND (250) ND (230) ND (530) ND (210) ND (2100) ND (11000) ND (18000) ND (42)

150 J 200 J 300 J ND (210) ND (2100) 6900 J 13000 J ND (42)

1,150 J 1,700 J 6,200 J 820 20,000 105,900 J 163,000 J 0

13968-32-T91.xls

Page 309: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 218 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1655 1656 1657 1658 1659 1660 1660 1661S-00-041002-GS-1655A S-00-041002-GS-1656 S-00-041002-GS-1657 S-00-041002-GS-1658 S-00-041002-GS-1659 S-06-041002-GS-1660 S-06-041002-GS-1660A S-06-041002-GS-1661

4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44) ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44) ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44) ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44) ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44) ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44) ND (42) ND (45) ND (46) ND (44) ND (48) ND (47) ND (45) ND (44)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 310: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 219 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1662 1663 1664 1665 1666 1667 1668 1669S-06-041002-GS-1662 S-06-041002-GS-1663 S-06-041002-GS-1664 S-06-041002-GS-1665 S-06-041002-GS-1666 S-06-041002-GS-1667 S-06-041002-GS-1668 S-06-041002-GS-1669

4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43) ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43) ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43) ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43) ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43) ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43) ND (44) ND (46) ND (42) ND (43) ND (43) ND (44) ND (44) ND (43)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 311: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 220 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1670 1671 1672 1673 1674 1675 1690 1690S-00-041002-JW-1670 S-00-041002-JW-1671 S-00-041002-GS-1672 S-00-041002-GS-1673 S-00-041002-GS-1674 S-00-041002-GS-1675 S-00-041202-JW-1690 S-00-041202-JW-1690A

4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/10/2002 4/12/2002 4/12/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46) ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46) ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46) ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46) ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46) ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46) ND (370) ND (390) ND (49) ND (45) ND (47) ND (49) ND (47) ND (46)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 312: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 221 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1691 1692 1693 1694 1695 1696 1697 1698S-00-041202-JW-1691 S-00-041202-JW-1692 S-00-041202-JW-1693 S-00-041202-JW-1694 S-00-041202-JW-1695 S-00-041202-JW-1696 S-00-041202-JW-1697 S-02-041202-JW-1698

4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) ND (43) ND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) ND (43) ND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) ND (43) ND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) ND (43) ND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) 29 JND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) ND (43) ND (43) ND (46) ND (48) ND (46) ND (45) ND (42) ND (48) 19 J

0 0 0 0 0 0 0 48 J

13968-32-T91.xls

Page 313: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 222 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1699 1700 1701 1702 1702 1703 1704 1705S-02-041202-JW-1699 S-02-041202-JW-1700 S-02-041202-JW-1701 S-02-041202-JW-1702 S-02-041202-JW-1702A S-02-041202-JW-1703 S-02-041202-JW-1704 S-02-041202-JW-1705

4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (57) ND (54) ND (46) ND (49) ND (48) ND (2300) ND (2200) ND (41) ND (57) ND (54) ND (46) ND (49) ND (48) ND (2300) ND (2200) ND (41) ND (57) ND (54) ND (46) ND (49) ND (48) ND (2300) ND (2200) ND (41) ND (57) ND (54) ND (46) ND (49) ND (48) ND (2300) ND (2200) ND (41)

44 J 120 J 83 ND (49) ND (48) 45000 20000 17 JND (57) ND (54) ND (46) ND (49) ND (48) ND (2300) ND (2200) ND (41)

25 J 84 J ND (46) ND (49) ND (48) 2900 1300 J ND (41)

69 J 204 J 83 0 0 47,900 21,300 J 17 J

13968-32-T91.xls

Page 314: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 223 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1706 1707 1708 1708 1709 1710 1711 1712S-02-041202-JW-1706 S-02-041202-JW-1707 S-02-041202-JW-1708 S-02-041202-JW-1708A S-02-041202-JW-1709 S-02-041202-JW-1710 S-02-041202-JW-1711 S-02-041202-JW-1712

4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (47) ND (43) ND (45) ND (43) ND (44) ND (44) ND (43) ND (46) ND (47) ND (43) ND (45) ND (43) ND (44) ND (44) ND (43) ND (46) ND (47) ND (43) ND (45) ND (43) ND (44) ND (44) ND (43) ND (46) ND (47) ND (43) ND (45) ND (43) ND (44) ND (44) ND (43)

42 J 170 ND (43) ND (45) ND (43) ND (44) ND (44) 74 ND (46) ND (47) ND (43) ND (45) ND (43) ND (44) ND (44) ND (43) ND (46) ND (47) ND (43) ND (45) ND (43) ND (44) ND (44) 40 J

42 J 170 0 0 0 0 0 114 J

13968-32-T91.xls

Page 315: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 224 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1713 1714 1715 1716 1717 1718 1719 1720S-02-041202-JW-1713 S-02-041202-JW-1714 S-02-041202-JW-1715 S-02-041202-JW-1716 S-02-041202-JW-1717 S-02-041202-JW-1718 S-02-041202-JW-1719 S-02-041202-JW-1720

4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (47) ND (43) ND (47) ND (44) ND (44) ND (58) ND (46) ND (45) ND (47) ND (43) ND (47) ND (44) ND (44) ND (58) ND (46) ND (45) ND (47) ND (43) ND (47) ND (44) ND (44) ND (58) ND (46) ND (45) ND (47) ND (43) ND (47) ND (44) ND (44) ND (58) ND (46) ND (45)

26 J ND (43) ND (47) 62 ND (44) 80 36 J ND (45) ND (47) ND (43) ND (47) ND (44) ND (44) ND (58) ND (46) ND (45) ND (47) ND (43) ND (47) ND (44) ND (44) 41 J ND (46) ND (45)

26 J 0 0 62 0 121 J 36 J 0

13968-32-T91.xls

Page 316: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 225 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1720 1721 1722 1723 1724 1725 1726 1727S-02-041202-JW-1720A S-02-041202-JW-1721 S-02-041202-JW-1722 S-02-041202-JW-1723 S-02-041202-JW-1724 S-02-041202-JW-1725 S-81-041602-JW-1726 S-81-041602-GS-1727

4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/12/2002 4/16/2002 4/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (41) ND (47) ND (48) ND (54) ND (43) ND (63) ND (54) ND (44) ND (41) ND (47) ND (48) ND (54) ND (43) ND (63) ND (54) ND (44) ND (41) ND (47) ND (48) ND (54) ND (43) ND (63) ND (54) ND (44) ND (41) ND (47) ND (48) ND (54) ND (43) ND (63) ND (54) ND (44) ND (41) ND (47) ND (48) 210 ND (43) 840 580 ND (44) ND (41) ND (47) ND (48) ND (54) ND (43) ND (63) ND (54) ND (44) ND (41) ND (47) ND (48) ND (54) ND (43) 150 120

0 0 0 0 210 0 990 700

13968-32-T91.xls

Page 317: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 226 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1728 1729 1730 1731 1731 1732 1733 1734S-81-041602-JW-1728 S-81-041602-GS-1729 S-81-041602-JW-1730 S-37-041602-JW-1731 S-37-041602-JW-1731A S-37-041602-GS-1732 S-37-041602-GS-1733 S-28-041602-JW-1734

4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (240) ND (53) ND (55) ND (260) ND (460) ND (260) ND (2300) ND (46) ND (240) ND (53) ND (55) ND (260) ND (460) ND (260) ND (2300) ND (46) ND (240) ND (53) ND (55) ND (260) ND (460) ND (260) ND (2300) ND (46) ND (240) ND (53) ND (55) ND (260) ND (460) ND (260) ND (2300) ND (46)

1700 250 150 2500 2900 2200 15000 ND (46) ND (240) ND (53) ND (55) ND (260) ND (460) ND (260) ND (2300) ND (46)

200 J 63 31 J 250 J 400 J 250 J 2000 J ND (46)

1,900 J 313 181 J 2,750 J 3,300 J 2,450 J 17,000 J 0

13968-32-T91.xls

Page 318: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 227 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1735 1735 1736 1737 1738 1739 1740 1741S-28-041602-GS-1735 S-28-041602-GS-1735A S-28-041602-JW-1736 S-28-041602-GS-1737 S-28-041602-JW-1738 S-28-041602-GS-1739 S-28-041602-GS-1740 S-28-041602-GS-1741

4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (42) ND (42) ND (47) ND (49) ND (45) ND (43) ND (50) ND (52) ND (42) ND (42) ND (47) ND (49) ND (45) ND (43) ND (50) ND (52) ND (42) ND (42) ND (47) ND (49) ND (45) ND (43) ND (50) ND (52) ND (42) ND (42) ND (47) ND (49) ND (45) ND (43) ND (50) ND (52) ND (42) ND (42) ND (47) ND (49) ND (45) ND (43) ND (50) ND (52)

34 J 32 J ND (47) ND (49) ND (45) ND (43) ND (50) ND (52) ND (42) ND (42) ND (47) ND (49) ND (45) ND (43) ND (50) ND (52)

34 J 32 J 0 0 0 0 0 0

13968-32-T91.xls

Page 319: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 228 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1742 1743 1743 1744 1745 1746 1747 1748S-57-041602-GS-1742 S-57-041602-GS-1743 S-57-041602-GS-1743A S-57-041602-GS-1744 S-57-041602-GS-1745 S-57-041602-GS-1746 S-57-041602-GS-1747 S-57-041602-GS-1748

4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002 4/16/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (230) ND (51) ND (96) ND (50) ND (86) ND (43) ND (43) ND (42) ND (230) ND (51) ND (96) ND (50) ND (86) ND (43) ND (43) ND (42) ND (230) ND (51) ND (96) ND (50) ND (86) ND (43) ND (43) ND (42) ND (230) ND (51) ND (96) ND (50) ND (86) ND (43) ND (43) ND (42)

1000 310 750 210 810 ND (43) 420 ND (42) ND (230) ND (51) ND (96) ND (50) ND (86) ND (43) ND (43) ND (42)

300 85 190 ND (50) 230 ND (43) 140 ND (42)

1,300 395 940 210 1,040 0 560 0

13968-32-T91.xls

Page 320: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 229 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1749 1750 1751 1751 1752 1753 1754 1755S-57-041602-GS-1749 S-57-041602-GS-1750 S-00-042202-LM-1751 S-00-042202-LM-1751A S-00-042202-LM-1752 S-00-042202-LM-1753 S-00-042202-LM-1754 S-00-042202-GS-1755

4/16/2002 4/16/2002 4/22/2002 4/22/2002 4/22/2002 4/22/2002 4/22/2002 4/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (43) ND (43) ND (46) ND (45) ND (45) ND (47) ND (42) ND (41) ND (43) ND (43) ND (46) ND (45) ND (45) ND (47) ND (42) ND (41) ND (43) ND (43) ND (46) ND (45) ND (45) ND (47) ND (42) ND (41) ND (43) ND (43) ND (46) ND (45) ND (45) ND (47) ND (42) ND (41)

180 210 ND (46) ND (45) ND (45) ND (47) ND (42) 43 ND (43) ND (43) ND (46) ND (45) ND (45) ND (47) ND (42) ND (41)

86 80 ND (46) ND (45) ND (45) ND (47) ND (42) ND (41)

266 290 0 0 0 0 0 43

13968-32-T91.xls

Page 321: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 230 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1755 1757 1758 1758 1761 1761 1766 1766S-00-042202-GS-1755A S-00-042202-GS-1757 S-00-042202-GS-1758 S-00-042202-GS-1758A S-00-042202-GS-1761 S-00-042202-GS-1761A S-00-042302-JW-1766 S-00-042302-JW-1766A

4/22/2002 4/22/2002 4/22/2002 4/22/2002 4/22/2002 4/22/2002 4/23/2002 4/23/2002(0.33-0.67) (0-0.33) (0-0.33) (0.33-0.67) (0-0.33) (0.33-0.67) (0-0.33) (0.33-0.67)

ND (41) ND (23000) ND (46) ND (42) ND (42) ND (42) ND (46) ND (41) ND (41) ND (23000) ND (46) ND (42) ND (42) ND (42) ND (46) ND (41) ND (41) ND (23000) ND (46) ND (42) ND (42) ND (42) ND (46) ND (41) ND (41) ND (23000) ND (46) ND (42) ND (42) ND (42) ND (46) ND (41) ND (41) 220000 97 26 J 420 590 460 160 ND (41) ND (23000) ND (46) ND (42) ND (42) ND (42) ND (46) ND (41) ND (41) 15000 J ND (46) ND (42) 85 100 50 9.6 J

0 235,000 J 97 26 J 505 690 510 169.6 J

13968-32-T91.xls

Page 322: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 231 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1766 1767 1770 1770 1770 1770 1773 1775S-00-042302-JW-1766B S-00-042302-GS-1767 S-00-042302-JW-1770 S-00-042302-JW-1770C S-00-042302-JW-1770A S-00-042302-JW-1770B S-00-042302-GS-1773 S-00-042302-JW-1775

4/23/2002 4/23/2002 4/23/2002 4/23/2002 4/23/2002 4/23/2002 4/23/2002 4/23/2002(0.33-0.67) (0-0.33) (0-0.33) (0-0.33) (0.33-0.67) (0.67-1) (0-0.33) (0-0.33)Duplicate Duplicate

ND (41) ND (250) ND (200) ND (440) ND (40) ND (40) ND (950) ND (470) ND (41) ND (250) ND (200) ND (440) ND (40) ND (40) ND (950) ND (470) ND (41) ND (250) ND (200) ND (440) ND (40) ND (40) ND (950) ND (470) ND (41) ND (250) ND (200) ND (440) ND (40) 140 ND (950) ND (470)

200 1800 1600 2300 81 ND (40) 6400 4200 ND (41) ND (250) ND (200) ND (440) ND (40) ND (40) ND (950) ND (470)

9.2 J 180 J 170 J 220 J ND (40) ND (40) 500 J 400 J

209.2 J 1,980 J 1,770 J 2,520 J 81 140 6,900 J 4,600 J

13968-32-T91.xls

Page 323: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 232 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1775 1777 1777 1781 1781 1781 1781 1781S-00-042302-JW-1775A S-00-042402-GS-1777 S-00-042402-GS-1777A S-00-042502-JW-1781 S-00-042502-JW-1781A S-00-042502-JW-1781B S-00-042502-JW-1781C S-00-042502-JW-1781D

4/23/2002 4/24/2002 4/24/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002(0-0.33) (0-0.33) (0.33-0.67) (0-0.33) (0.33-0.67) (0.67-1) (1-1.33) (1.33-1.67)

Duplicate

ND (930) ND (4700) ND (4600) ND (5100) ND (900) ND (210) ND (220) ND (430) ND (930) ND (4700) ND (4600) ND (5100) ND (900) ND (210) ND (220) ND (430) ND (930) ND (4700) ND (4600) ND (5100) ND (900) ND (210) ND (220) ND (430) ND (930) ND (4700) ND (4600) ND (5100) ND (900) ND (210) ND (220) ND (430)

5300 74000 40000 19000 9900 1100 1100 1700 ND (930) ND (4700) ND (4600) ND (5100) ND (900) ND (210) ND (220) ND (430)

530 J ND (4700) 2800 J 1400 J 780 J 76 J 75 J ND (430)

5,830 J 74,000 42,800 J 20,400 J 10,680 J 1,176 J 1,175 J 1,700

13968-32-T91.xls

Page 324: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 233 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1781 1782 1782 1782 1782 1783 1783 1783S-00-042502-JW-1781E S-00-042502-LM-1782 S-00-042502-LM-1782A S-00-042502-LM-1782B S-00-042502-LM-1782C S-00-042502-JW-1783 S-00-042502-JW-1783A S-00-042502-JW-1783B

4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002(1.67-2) (0-0.33) (0.33-0.67) (0.67-1) (1-1.33) (0-0.33) (0.33-0.67) (0.67-1)

ND (870) ND (8600) ND (210) ND (880) ND (43) ND (430) ND (42) ND (42) ND (870) ND (8600) ND (210) ND (880) ND (43) ND (430) ND (42) ND (42) ND (870) ND (8600) ND (210) ND (880) ND (43) ND (430) ND (42) ND (42) ND (870) ND (8600) ND (210) ND (880) ND (43) ND (430) ND (42) ND (42)

7200 98000 1600 5300 490 1500 690 170 ND (870) ND (8600) ND (210) ND (880) ND (43) ND (430) ND (42) ND (42)

810 J 8600 110 J 430 J 31 J 160 J 88 25 J

8,010 J 106,600 1,710 J 5,730 J 521 J 1,660 J 778 195 J

13968-32-T91.xls

Page 325: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 234 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1783 1783 1783 1784 1784 1784 1784 1785S-00-042502-JW-1783C S-00-042502-JW-1783D S-00-042502-JW-1783E S-00-042502-JW-1784 S-00-042502-JW-1784A S-00-042502-JW-1784B S-00-042502-JW-1784C S-00-050202-JW-1785

4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 4/25/2002 5/2/2002(0.67-1) (1-1.33) (1.33-1.67) (0-0.33) (0.33-0.67) (0.67-1) (1-1.33) (0-0.33)

Duplicate

ND (41) ND (44) ND (43) ND (46) ND (41) ND (42) ND (42) ND (47) ND (41) ND (44) ND (43) ND (46) ND (41) ND (42) ND (42) ND (47) ND (41) ND (44) ND (43) ND (46) ND (41) ND (42) ND (42) ND (47) ND (41) ND (44) ND (43) ND (46) ND (41) ND (42) ND (42) ND (47)

89 ND (44) ND (43) 160 73 19 J 53 ND (47) ND (41) ND (44) ND (43) ND (46) ND (41) ND (42) ND (42) ND (47) ND (41) ND (44) ND (43) 65 37 J ND (42) 15 J ND (47)

89 0 0 225 110 J 19 J 68 J 0

13968-32-T91.xls

Page 326: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 235 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1785 1786 1787 1788 1789 1790 1791 1791S-00-050202-JW-1785A S-00-050202-JW-1786 S-00-050202-JW-1787 S-00-050202-JW-1788 S-00-050202-JW-1789 S-00-050202-JW-1790 S-00-050602-GS-1791 S-00-050602-GS-1791A

5/2/2002 5/2/2002 5/2/2002 5/2/2002 5/2/2002 5/2/2002 5/6/2002 5/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42) ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42) ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42) ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42) ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42) ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42) ND (45) ND (44) ND (46) ND (44) ND (45) ND (46) ND (44) ND (42)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 327: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 236 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1792 1793 1794 1795 1796 1797 1798 1798S-00-050602-GS-1792 S-00-050602-GS-1793 S-00-050602-GS-1794 S-00-050602-LM-1795 S-00-050602-GS-1796 S-00-050602-LM-1797 S-00-050702-GS-1798 S-00-050702-GS-1798A

5/6/2002 5/6/2002 5/6/2002 5/6/2002 5/6/2002 5/6/2002 5/7/2002 5/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (53) ND (63) ND (43) ND (42) ND (48) ND (46) ND (46) ND (46) ND (53) ND (63) ND (43) ND (42) ND (48) ND (46) ND (46) ND (46) ND (53) ND (63) ND (43) ND (42) ND (48) ND (46) ND (46) ND (46) ND (53) ND (63) ND (43) ND (42) ND (48) ND (46) ND (46) ND (46) ND (53) 15 J ND (43) 170 140 ND (46) ND (46) ND (46) ND (53) ND (63) ND (43) ND (42) ND (48) ND (46) ND (46) ND (46) ND (53) ND (63) ND (43) ND (42) 41 J ND (46) ND (46)

0 0 15 J 0 170 181 J 0 0

13968-32-T91.xls

Page 328: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 237 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1799 1800 1801 1802 1803 1804 1805 1806S-00-050702-JW-1799 S-00-050702-GS-1800 S-00-050702-JW-1801 S-00-050702-GS-1802 S-00-050702-JW-1803 S-00-050702-GS-1804 S-00-050702-GS-1805 S-00-050702-JW-1806

5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46) ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46) ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46) ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46) ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46) ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46) ND (53) ND (44) ND (48) ND (51) ND (43) ND (45) ND (48) ND (46)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 329: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 238 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1807 1807 1808 1809 1810 1811 1812 1813S-00-050702-JW-1807 S-00-050702-JW-1807A S-00-050702-GS-1808 S-00-050702-JW-1809 S-00-050702-GS-1810 S-00-050702-JW-1811 S-00-050702-JW-1812 S-00-050702-GS-1813

5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45) ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45) ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45) ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45) ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45) ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45) ND (46) ND (45) ND (47) ND (47) ND (46) ND (45) ND (53) ND (45)

0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 330: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 239 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1814 1815 1816 1817 1818 1818 1819 1820S-00-050702-JW-1814 S-00-050702-GS-1815 S-00-050702-JW-1816 S-00-050702-LM-1817 S-00-050702-GS-1818 S-00-050702-GS-1818A S-00-050702-LM-1819 S-00-050702-LM-1820

5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (52) ND (41) ND (56) ND (47) ND (46) ND (41) ND (50) ND (48) ND (52) ND (41) ND (56) ND (47) ND (46) ND (41) ND (50) ND (48) ND (52) ND (41) ND (56) ND (47) ND (46) ND (41) ND (50) ND (48) ND (52) ND (41) ND (56) ND (47) ND (46) ND (41) ND (50) ND (48) ND (52) ND (41) ND (56) ND (47) ND (46) ND (41) ND (50) ND (48) ND (52) ND (41) ND (56) ND (47) ND (46) ND (41) 140 ND (48) ND (52) ND (41) ND (56) 75 77 ND (41) ND (50)

0 0 0 0 75 77 0 140

13968-32-T91.xls

Page 331: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 240 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1821 1822 1823 1824 1825 1825 1826 1827S-00-050702-GS-1821 S-00-050702-GS-1822 S-00-050702-GS-1823 S-00-050702-GS-1824 S-00-050802-GS-1825 S-00-050802-GS-1825A S-00-050802-JW-1826 S-00-050802-GS-1827

5/7/2002 5/7/2002 5/7/2002 5/7/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (54) ND (45) ND (47) ND (46) ND (47) ND (48) ND (21) ND (48) ND (54) ND (45) ND (47) ND (46) ND (47) ND (48) ND (21) ND (48) ND (54) ND (45) ND (47) ND (46) ND (47) ND (48) ND (21) ND (48) ND (54) ND (45) ND (47) ND (46) ND (47) ND (48) ND (21) ND (48) ND (54) ND (45) ND (47) 39 J 37 J 85 1400 ND (48) ND (54) ND (45) ND (47) ND (46) ND (47) ND (48) ND (21) ND (48) ND (54) ND (45) ND (47) 17 J 19 J 23 J 210

0 0 0 0 56 J 56 J 108 J 1,610

13968-32-T91.xls

Page 332: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 241 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1828 1829 1830 1831 1832 1833 1834 1835S-00-050802-GS-1828 S-00-050802-JW-1829 S-00-050802-GS-1830 S-00-050802-JW-1831 S-00-050802-GS-1832 S-00-050802-JW-1833 S-00-050802-GS-1834 S-00-050802-GS-1835

5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (52) ND (49) ND (51) ND (240) ND (270) ND (99) ND (51) ND (55) ND (52) ND (49) ND (51) ND (240) ND (270) ND (99) ND (51) ND (55) ND (52) ND (49) ND (51) ND (240) ND (270) ND (99) ND (51) ND (55) ND (52) ND (49) ND (51) ND (240) ND (270) ND (99) ND (51) ND (55)

40 J 150 290 1100 1700 560 74 25 JND (52) ND (49) ND (51) ND (240) ND (270) ND (99) ND (51) ND (55)

21 J 68 48 J 120 J 190 J 110 27 J ND (55)

61 J 218 338 J 1,220 J 1,890 J 670 101 J 25 J

13968-32-T91.xls

Page 333: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 242 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1835 1836 1837 1838 1839 1840 1841 1842S-00-050802-GS-1835A S-00-050802-JW-1836 S-00-050802-JW-1837 S-00-050802-GS-1838 S-00-050802-GS-1839 S-00-050802-JW-1840 S-00-050802-GS-1841 S-00-050802-JW-1842

5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002 5/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (54) ND (50) ND (220) ND (2000) ND (49) ND (51) ND (50) ND (48) ND (54) ND (50) ND (220) ND (2000) ND (49) ND (51) ND (50) ND (48) ND (54) ND (50) ND (220) ND (2000) ND (49) ND (51) ND (50) ND (48) ND (54) ND (50) ND (220) ND (2000) ND (49) ND (51) ND (50) ND (48)

30 J 700 1500 26000 ND (49) ND (51) ND (50) ND (48) ND (54) ND (50) ND (220) ND (2000) ND (49) ND (51) ND (50) ND (48) ND (54) 150 230 4100 ND (49) ND (51) ND (50) ND (48)

30 J 850 1,730 30,100 0 0 0 0

13968-32-T91.xls

Page 334: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 243 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1843 1843 1844 1845 1846 1847 1848 1849S-00-050902-JW-1843 S-00-050902-JW-1843A S-00-050902-JW-1844 S-00-050902-JW-1845 S-00-050902-JW-1846 S-00-050902-JW-1847 S-00-050902-JW-1848 S-00-050902-JW-1849

5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (93) ND (45) ND (99) ND (100) ND (49) ND (220) ND (49) ND (45) ND (93) ND (45) ND (99) ND (100) ND (49) ND (220) ND (49) ND (45) ND (93) ND (45) ND (99) ND (100) ND (49) ND (220) ND (49) ND (45) ND (93) ND (45) ND (99) ND (100) ND (49) ND (220) ND (49) ND (45)

710 280 630 700 36 J 1400 250 38 JND (93) ND (45) ND (99) ND (100) ND (49) ND (220) ND (49) ND (45)

230 97 91 J 200 16 J 290 77 24 J

940 377 721 J 900 52 J 1,690 327 62 J

13968-32-T91.xls

Page 335: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 244 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1850 1851 1852 1852 1853 1854 1855 1856S-00-050902-JW-1850 S-00-050902-JW-1851 S-00-050902-JW-1852 S-00-050902-JW-1852A S-00-050902-JW-1853 S-00-050902-JW-1854 S-00-050902-JW-1855 S-00-050902-JW-1856

5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002 5/9/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (230) ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47) ND (230) ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47) ND (230) ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47) ND (230) ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47)

1200 ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47) ND (230) ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47)

230 ND (46) ND (48) ND (46) ND (50) ND (49) ND (47) ND (47)

1,430 0 0 0 0 0 0 0

13968-32-T91.xls

Page 336: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 245 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1857 1857 1858 1859 1860 1861 1862 1863S-00-051002-JW-1857 S-00-051002-JW-1857A S-00-051002-JW-1858 S-00-051002-JW-1859 S-00-051002-JW-1860 S-00-051002-JW-1861 S-00-051002-JW-1862 S-00-051002-JW-1863

5/10/2002 5/10/2002 5/10/2002 5/10/2002 5/10/2002 5/10/2002 5/10/2002 5/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (45) ND (44) ND (45) ND (45) ND (51) ND (46) ND (44) ND (48) ND (45) ND (44) ND (45) ND (45) ND (51) ND (46) ND (44) ND (48) ND (45) ND (44) ND (45) ND (45) ND (51) ND (46) ND (44) ND (48) ND (45) ND (44) ND (45) ND (45) ND (51) ND (46) ND (44) ND (48)

58 93 130 6.2 J 7.8 J 67 97 330 ND (45) ND (44) ND (45) ND (45) ND (51) ND (46) ND (44) ND (48)

12 J 28 J 30 J ND (45) ND (51) 17 J 39 J 62

70 J 121 J 160 J 6.2 J 7.8 J 84 J 136 J 392

13968-32-T91.xls

Page 337: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 246 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1864 1865 1865 1866 1867 1867 1868 1869S-00-051002-JW-1864 S-00-051002-JW-1865 S-00-051002-JW-1865A S-00-051002-JW-1866 S-052402-JW-1867 S-052402-JW-1867A S-052402-JW-1868 S-052402-JW-1869

5/10/2002 5/10/2002 5/10/2002 5/10/2002 5/24/2002 5/24/2002 5/24/2002 5/24/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (45) ND (43) ND (43) ND (52) ND (80) ND (180) ND (200) ND (410) ND (45) ND (43) ND (43) ND (52) ND (80) ND (180) ND (200) ND (410) ND (45) ND (43) ND (43) ND (52) ND (80) ND (180) ND (200) ND (410) ND (45) ND (43) ND (43) ND (52) ND (80) ND (180) ND (200) ND (410)

140 ND (43) ND (43) 230 1300 1300 1900 2400 ND (45) ND (43) ND (43) ND (52) ND (80) ND (180) ND (200) ND (410)

26 J ND (43) ND (43) 38 J 300 280 420 460

166 J 0 0 268 J 1,600 1,580 2,320 2,860

13968-32-T91.xls

Page 338: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 247 of 314

Sample Location: 1870 1871 1872 1873 1874 1875 1875 1876 1877Sample ID: S-052402-JW-1870 S-052402-JW-1871 S-052402-JW-1872 S-052402-JW-1873 S-052402-JW-1874 S-052802-GS-1875 S-052802-GS-1875A S-052802-GS-1876 S-052802-GS-1877Sample Date: 5/24/2002 5/24/2002 5/24/2002 5/24/2002 5/24/2002 5/28/2002 5/28/2002 5/28/2002 5/28/2002Sample Depth: (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (83) ND (82) ND (48) ND (200) ND (59) ND (41) ND (42) ND (45) ND (56) Aroclor-1221 (PCB-1221) ug/Kg ND (83) ND (82) ND (48) ND (200) ND (59) ND (41) ND (42) ND (45) ND (56) Aroclor-1232 (PCB-1232) ug/Kg ND (83) ND (82) ND (48) ND (200) ND (59) ND (41) ND (42) ND (45) ND (56) Aroclor-1242 (PCB-1242) ug/Kg ND (83) ND (82) ND (48) ND (200) ND (59) ND (41) ND (42) ND (45) ND (56) Aroclor-1248 (PCB-1248) ug/Kg 530 620 94 1400 27 J ND (41) ND (42) ND (45) ND (56) Aroclor-1254 (PCB-1254) ug/Kg ND (83) ND (82) ND (48) ND (200) ND (59) ND (41) ND (42) ND (45) ND (56) Aroclor-1260 (PCB-1260) ug/Kg 110 84 19 J 280 ND (59) ND (41) ND (42) ND (45) ND (56)

Sum of Detected PCBs (ND=0) ug/Kg 640 704 113 J 1,680 27 J 0 0 0 0

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 339: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 248 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1878 1879 1880 1881 1882 1882 1883 1884 1885S-052802-GS-1878 S-052802-JW-1879 S-052802-JW-1880 S-052802-JW-1881 S-00-052902-GS-1882 S-00-052902-GS-1882A S-00-052902-GS-1883 S-00-052902-GS-1884 S-00-052902-GS-1885

5/28/2002 5/28/2002 5/28/2002 5/28/2002 5/29/2002 5/29/2002 5/29/2002 5/29/2002 5/29/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (48) ND (51) ND (43) ND (45) ND (49) UJ ND (45) UJ ND (45) UJ ND (45) UJ ND (45) UJND (48) ND (51) ND (43) ND (45) ND (49) UJ ND (45) UJ ND (45) UJ ND (45) UJ ND (45) UJND (48) ND (51) ND (43) ND (45) ND (49) UJ ND (45) UJ ND (45) UJ ND (45) UJ ND (45) UJND (48) ND (51) ND (43) ND (45) ND (49) UJ ND (45) UJ ND (45) UJ ND (45) UJ ND (45) UJND (48) ND (51) ND (43) ND (45) ND (49) UJ ND (45) UJ ND (45) UJ ND (45) UJ ND (45) UJND (48) ND (51) ND (43) ND (45) ND (49) ND (45) ND (45) ND (45) ND (45) ND (48) ND (51) ND (43) ND (45) ND (49) ND (45) ND (45) ND (45) ND (45)

0 0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 340: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 249 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1886 1886 1887 1888 1889 1890 1891 1892 1893S-053002-GS-1886 S-053002-GS-1886A S-053002-JW-1887 S-053002-GS-1888 S-053002-JW-1889 S-053002-GS-1890 S-053002-GS-1891 S-053002-JW-1892 S-053002-JW-1893

5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) ND (43) ND (49) ND (47) ND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) ND (43) ND (49) ND (47) ND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) ND (43) ND (49) ND (47) ND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) ND (43) ND (49) ND (47) ND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) ND (43) ND (49) ND (47) ND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) UJ ND (43) UJ ND (49) UJ ND (47) UJND (44) UJ ND (44) UJ ND (46) UJ ND (42) UJ ND (46) UJ ND (43) UJ ND (43) UJ ND (49) UJ ND (47) UJ

0 0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 341: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 250 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1894 1895 1896 1897 1897 1898 1899 1900 1901S-053002-GS-1894 S-053002-GS-1895 S-053002-JW-1896 S-053002-GS-1897 S-053002-GS-1897A S-053002-JW-1898 S-053002-GS-1899 S-053002-GS-1900 S-053002-JW-1901

5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (46) ND (46) ND (50) ND (44) ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJND (46) ND (46) ND (50) ND (44) ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJND (46) ND (46) ND (50) ND (44) ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJND (46) ND (46) ND (50) ND (44) ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJND (46) ND (46) ND (50) ND (44) ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJ

ND (46) UJ ND (46) UJ ND (50) UJ ND (44) UJ ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJND (46) UJ ND (46) UJ ND (50) UJ ND (44) UJ ND (44) UJ ND (44) UJ ND (42) UJ ND (44) UJ ND (50) UJ

0 0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 342: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 251 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1902 1903 1904 1905 1906 1906 1907 1908 1909S-053002-JW-1902 S-053002-GS-1903 S-053002-JW-1904 S-053002-JW-1905 S-053002-GS-1906 S-053002-GS-1906A S-053002-JW-1907 S-053002-GS-1908 S-053002-GS-1909

5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002 5/30/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) ND (44) ND (43) ND (44) ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) ND (44) ND (43) ND (44) ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) ND (44) ND (43) ND (44) ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) ND (44) ND (43) ND (44) ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) ND (44) ND (43) ND (44) ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) 27 J 28 J ND (44) ND (45) UJ ND (54) UJ ND (44) UJ ND (45) UJ ND (42) UJ ND (43) ND (44) ND (43) ND (44)

0 0 0 0 0 0 27 J 28 J 0

13968-32-T91.xls

Page 343: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 252 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1910 1911 1912 1913 1914 1914 1915 1915 1916S-053002-GS-1910 S-053002-GS-1911 S-053002-GS-1912 S-060602-JW-1913 S-060602-GS-1914 S-060602-GS-1914A S-060702-GS-1915 S-060702-GS-1915A S-060702-GS-1916

5/30/2002 5/30/2002 5/30/2002 6/6/2002 6/6/2002 6/6/2002 6/7/2002 6/7/2002 6/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (50) ND (42) ND (40) ND (210) ND (210) ND (220) ND (48) ND (46) ND (95) ND (50) ND (42) ND (40) ND (210) ND (210) ND (220) ND (48) ND (46) ND (95) ND (50) ND (42) ND (40) ND (210) ND (210) ND (220) ND (48) ND (46) ND (95) ND (50) ND (42) ND (40) ND (210) ND (210) ND (220) ND (48) ND (46) ND (95) ND (50) ND (42) ND (40) 2100 2300 2000 ND (48) ND (46) 1100 ND (50) ND (42) ND (40) UJ ND (210) ND (210) ND (220) ND (48) ND (46) ND (95) ND (50) ND (42) ND (40) UJ 400 430 430 ND (48) ND (46) 270

0 0 0 2,500 2,730 2,430 0 0 1,370

13968-32-T91.xls

Page 344: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 253 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1917 1918 1919 1920 1921 1922 1923 1924 1925S-060702-JW-1917 S-060702-JW-1918 S-060702-JW-1919 S-060702-JW-1920 S-060702-GS-1921 S-060702-GS-1922 S-060702-JW-1923 S-060702-JW-1924 S-060702-GS-1925

6/7/2002 6/7/2002 6/7/2002 6/7/2002 6/7/2002 6/7/2002 6/7/2002 6/7/2002 6/7/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (43) ND (44) ND (230) ND (46) ND (260) ND (450) ND (250) ND (95) ND (96) ND (43) ND (44) ND (230) ND (46) ND (260) ND (450) ND (250) ND (95) ND (96) ND (43) ND (44) ND (230) ND (46) ND (260) ND (450) ND (250) ND (95) ND (96) ND (43) ND (44) ND (230) ND (46) ND (260) ND (450) ND (250) ND (95) ND (96)

19 J 670 J 1800 17 J 1000 3800 2100 740 820 ND (43) ND (44) ND (230) ND (46) ND (260) ND (450) ND (250) ND (95) ND (96) ND (43) 200 J 340 ND (46) 260 960 450 130 140

19 J 870 J 2,140 17 J 1,260 4,760 2,550 870 960

13968-32-T91.xls

Page 345: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 254 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1925 1926 1927 1928 1928 1929 1930 1931 1932S-060702-GS-1925A S-060702-GS-1926 S-060702-GS-1927 S-061002-GS-1928 S-061002-GS-1928A S-061002-JW-1929 S-061002-JW-1930 S-061002-GS-1931 S-061002-GS-1932

6/7/2002 6/7/2002 6/7/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (51) ND (230) ND (290) ND (83) ND (82) ND (4300) ND (730) ND (23000) ND (470) ND (51) ND (230) ND (290) ND (83) ND (82) ND (4300) ND (730) ND (23000) ND (470) ND (51) ND (230) ND (290) ND (83) ND (82) ND (4300) ND (730) ND (23000) ND (470) ND (51) ND (230) ND (290) ND (83) ND (82) ND (4300) ND (730) ND (23000) ND (470)

490 1500 2400 360 420 27000 4800 130000 3500 ND (51) ND (230) ND (290) ND (83) ND (82) ND (4300) ND (730) ND (23000) ND (470)

130 330 360 82 J 110 2800 J 1100 12000 J 800

620 1,830 2,760 442 J 530 29,800 J 5,900 142,000 J 4,300

13968-32-T91.xls

Page 346: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 255 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1933 1934 1935 1936 1937 1938 1938 1939 1940S-061002-GS-1933 S-061002-JW-1934 S-061002-GS-1935 S-061002-GS-1936 S-061002-GS-1937 S-061002-JW-1938 S-061002-JW-1938A S-061002-GS-1939 S-061002-JW-1940

6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002 6/10/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (1800) ND (87000) ND (9100) ND (1900) ND (3900) ND (8700) ND (2100) ND (720) ND (500) ND (1800) ND (87000) ND (9100) ND (1900) ND (3900) ND (8700) ND (2100) ND (720) ND (500) ND (1800) ND (87000) ND (9100) ND (1900) ND (3900) ND (8700) ND (2100) ND (720) ND (500) ND (1800) ND (87000) ND (9100) ND (1900) ND (3900) ND (8700) ND (2100) ND (720) ND (500)

13000 650000 79000 12000 ND (3900) 88000 12000 5200 1700 ND (1800) ND (87000) ND (9100) ND (1900) 31000 ND (8700) ND (2100) ND (720) ND (500)

1800 61000 J 7200 J 1600 J ND (3900) 9700 2100 640 J 270 J

14,800 711,000 J 86,200 J 13,600 J 31,000 97,700 14,100 5,840 J 1,970 J

13968-32-T91.xls

Page 347: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 256 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1941 1942 1943 1943 1944 1945 1946 1947 1948S-061002-GS-1941 S-061002-GS-1942 S-061102-JW-1943 S-061102-JW-1943A S-061102-JW-1944 S-061102-JW-1945 S-061102-JW-1946 S-061102-JW-1947 S-061102-JW-1948

6/10/2002 6/10/2002 6/11/2002 6/11/2002 6/11/2002 6/11/2002 6/11/2002 6/11/2002 6/11/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (7800) ND (840) ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45) ND (7800) ND (840) ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45) ND (7800) ND (840) ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45) ND (7800) ND (840) ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45)

100000 5200 ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45) ND (7800) ND (840) ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45)

11000 890 ND (43) ND (41) ND (39) ND (44) ND (41) ND (43) ND (45)

111,000 6,090 0 0 0 0 0 0 0

13968-32-T91.xls

Page 348: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 257 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1949 1950 1951 1952 1952 1953 1954 1955 1956S-061102-JW-1949 S-061102-JW-1950 S-070102-JW-1951 S-070102-JW-1952 S-070102-JW-1952A S-070102-JW-1953 S-070102-JW-1954 S-070102-JW-1955 S-070102-JW-1956

6/11/2002 6/11/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (51) ND (42) ND (37) ND (35) ND (42) ND (42) ND (44) ND (48) ND (44) ND (51) ND (42) ND (37) ND (35) ND (42) ND (42) ND (44) ND (48) ND (44) ND (51) ND (42) ND (37) ND (35) ND (42) ND (42) ND (44) ND (48) ND (44) ND (51) ND (42) ND (37) ND (35) ND (42) ND (42) ND (44) ND (48)

8.7 19 7.1 J ND (37) ND (35) ND (42) ND (42) ND (44) 17 JND (44) ND (51) ND (42) ND (37) ND (35) ND (42) ND (42) ND (44) ND (48)

11 15 ND (42) ND (37) ND (35) ND (42) ND (42) ND (44) ND (48)

19.7 34 7.1 J 0 0 0 0 0 17 J

13968-32-T91.xls

Page 349: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 258 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1957 1958 1959 1960 1961 1961 1962 1963 1964S-070102-JW-1957 S-070102-JW-1958 S-070102-JW-1959 S-070102-JW-1960 S-070102-JW-1961 S-070102-JW-1961A S-070102-JW-1962 S-070102-JW-1963 S-070102-JW-1964

7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (49) ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39) ND (49) ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39) ND (49) ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39) ND (49) ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39)

60 ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39) ND (49) ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39) ND (49) ND (43) ND (41) ND (45) ND (47) ND (50) ND (41) ND (40) ND (39)

60 0 0 0 0 0 0 0 0

13968-32-T91.xls

Page 350: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 259 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1965 1966 1966 1967 1968 1969 1970 1971 1972S-070102-JW-1965 S-070102-JW-1966 S-070102-JW-1966A S-070102-JW-1967 S-070102-JW-1968 S-070102-JW-1969 S-070102-JW-1970 S-070102-JW-1971 S-070102-JW-1972

7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002 7/1/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (44) ND (41) ND (41) ND (55) ND (33) ND (41) ND (43) ND (44) ND (40) ND (44) ND (41) ND (41) ND (55) ND (33) ND (41) ND (43) ND (44) ND (40) ND (44) ND (41) ND (41) ND (55) ND (33) ND (41) ND (43) ND (44) ND (40) ND (44) ND (41) ND (41) ND (55) ND (33) ND (41) ND (43) ND (44) ND (40) ND (44) ND (41) ND (41) ND (55) 28 J ND (41) 40 J ND (44) 6.3 JND (44) ND (41) ND (41) ND (55) ND (33) ND (41) ND (43) ND (44) ND (40) ND (44) ND (41) ND (41) 30 J 54 ND (41) 32 J ND (44) ND (40)

0 0 0 30 J 82 J 0 72 J 0 6.3 J

13968-32-T91.xls

Page 351: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 260 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1973 1973 1974 1975 1976 1977 1978 1978 1979S-070202-JW-1973 S-070202-JW-1973A S-070202-JW-1974 S-070202-JW-1975 S-070202-JW-1976 S-072202-JW-1977 S-072202-JW-1978 S-072202-JW-1978A S-072202-JW-1979

7/2/2002 7/2/2002 7/2/2002 7/2/2002 7/2/2002 7/22/2002 7/22/2002 7/22/2002 7/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (42) ND (43) ND (43) ND (43) ND (43) R ND (2400) ND (2400) ND (2000) ND (42) ND (43) ND (43) ND (43) ND (43) R ND (2400) ND (2400) ND (2000) ND (42) ND (43) ND (43) ND (43) ND (43) R ND (2400) ND (2400) ND (2000) ND (42) ND (43) ND (43) ND (43) ND (43) R ND (2400) ND (2400) ND (2000)

17 J 19 J ND (43) 17 J ND (43) R ND (2400) ND (2400) 14000 ND (42) ND (43) ND (43) ND (43) ND (43) 67 J 12000 14000 ND (2000) ND (42) ND (43) ND (43) ND (43) ND (43) R ND (2400) ND (2400) ND (2000)

17 J 19 J 0 17 J 0 67 J 12,000 14,000 14,000

13968-32-T91.xls

Page 352: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 261 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1980 1981 1982 1983 1984 1985 1986 1987 1987S-072202-JW-1980 S-072202-JW-1981 S-072202-JW-1982 S-072202-JW-1983 S-072202-JW-1984 S-072202-JW-1985 S-072202-JW-1986 S-072202-JW-1987 S-072202-JW-1987A

7/22/2002 7/22/2002 7/22/2002 7/22/2002 7/22/2002 7/22/2002 7/22/2002 7/22/2002 7/22/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.167) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (35) ND (2100) ND (43) ND (4300) ND (45) ND (40) ND (220) ND (46) ND (45) ND (35) ND (2100) ND (43) ND (4300) ND (45) ND (40) ND (220) ND (46) ND (45) ND (35) ND (2100) ND (43) ND (4300) ND (45) ND (40) ND (220) ND (46) ND (45) ND (35) ND (2100) ND (43) ND (4300) ND (45) ND (40) ND (220) ND (46) ND (45) ND (35) 21000 ND (43) 35000 ND (45) ND (40) 1700 ND (46) ND (45)

220 ND (2100) ND (43) ND (4300) ND (45) ND (40) ND (220) ND (46) ND (45) ND (35) ND (2100) ND (43) ND (4300) ND (45) ND (40) ND (220) ND (46) ND (45)

220 21,000 0 35,000 0 0 1700 0 0

13968-32-T91.xls

Page 353: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 262 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1988 1989 1990 1991 1991 1991 1991 1991 1992S-072202-JW-1988 S-072202-JW-1989 S-072202-JW-1990 S-072302-JW-1991 S-072302-JW-1991A S-072302-JW-1991B S-072302-JW-1991C S-072302-JW-1991D S-072302-JW-1992

7/22/2002 7/22/2002 7/22/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (43) ND (2100) ND (4000) ND (200) ND (88) ND (40) ND (40) ND (41) ND (43) ND (43) ND (2100) ND (4000) ND (200) ND (88) ND (40) ND (40) ND (41) ND (43) ND (43) ND (2100) ND (4000) ND (200) ND (88) ND (40) ND (40) ND (41) ND (43) ND (43) ND (2100) ND (4000) ND (200) ND (88) ND (40) ND (40) ND (41) ND (43) ND (43) 22000 38000 1800 1100 340 38 J 52 ND (43) ND (43) ND (2100) ND (4000) ND (200) ND (88) ND (40) ND (40) ND (41) ND (43) ND (43) ND (2100) ND (4000) 200 130 ND (40) ND (40) ND (41) ND (43)

0 22,000 38,000 2,000 1,230 340 38 J 52 0

13968-32-T91.xls

Page 354: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 263 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1992 1992 1992 1993 1993 1993 1993 1993 1994S-072302-JW-1992A S-072302-JW-1992B S-072302-JW-1992C S-072302-JW-1993 S-072302-JW-1993A S-072302-JW-1993B S-072302-JW-1993C S-072302-JW-1993D S-072302-JW-1994

7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (41) R ND (41) ND (2200) ND (2100) ND (400) ND (200) ND (40) ND (410) ND (41) R ND (41) ND (2200) ND (2100) ND (400) ND (200) ND (40) ND (410) ND (41) R ND (41) ND (2200) ND (2100) ND (400) ND (200) ND (40) ND (410) ND (41) R ND (41) ND (2200) ND (2100) ND (400) ND (200) ND (40) ND (410) ND (41) R ND (41) 14000 17000 4800 1800 260 2800 ND (41) R ND (41) ND (2200) ND (2100) ND (400) ND (200) ND (40) ND (410) ND (41) R ND (41) 1400 J 1800 J 430 ND (200) 23 J 320 J

0 N/A 0 15,400 J 18,800 J 5,230 1,800 283 J 3,120 J

13968-32-T91.xls

Page 355: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 264 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1994 1994 1994 1995 1995 1996 1996 1996 1996S-072302-JW-1994A S-072302-JW-1994B S-072302-JW-1994C S-072302-JW-1995 S-072302-JW-1995A S-072302-JW-1996 S-072302-JW-1996A S-072302-JW-1996B S-072302-JW-1996C

7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2)

Duplicate

ND (200) ND (41) ND (41) ND (43) ND (42) ND (38) ND (38) ND (40) ND (40) ND (200) ND (41) ND (41) ND (43) ND (42) ND (38) ND (38) ND (40) ND (40) ND (200) ND (41) ND (41) ND (43) ND (42) ND (38) ND (38) ND (40) ND (40) ND (200) ND (41) ND (41) ND (43) ND (42) ND (38) ND (38) ND (40) ND (40)

820 170 120 ND (43) ND (42) ND (38) ND (38) ND (40) ND (40) ND (200) ND (41) 59 ND (43) ND (42) ND (38) ND (38) ND (40) ND (40)

90 J 13 J ND (41) ND (43) ND (42) ND (38) ND (38) ND (40) ND (40)

910 J 183 J 179 0 0 0 0 0 0

13968-32-T91.xls

Page 356: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 265 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

1997 1997 1997 1997 1998 1998 1998 1998 1999S-072302-JW-1997 S-072302-JW-1997A S-072302-JW-1997B S-072302-JW-1997C S-072302-JW-1998 S-072302-JW-1998A S-072302-JW-1998B S-072302-JW-1998C S-072302-JW-1999

7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

ND (210) ND (200) ND (81) ND (41) ND (430) ND (79) ND (40) ND (41) ND (2300) ND (210) ND (200) ND (81) ND (41) ND (430) ND (79) ND (40) ND (41) ND (2300) ND (210) ND (200) ND (81) ND (41) ND (430) ND (79) ND (40) ND (41) ND (2300) ND (210) ND (200) ND (81) ND (41) ND (430) ND (79) ND (40) ND (41) ND (2300)

2800 1300 520 65 3900 1400 370 20 J 27000 ND (210) ND (200) ND (81) ND (41) ND (430) ND (79) ND (40) ND (41) ND (2300)

350 170 J 76 J ND (41) 310 J 130 33 J ND (41) ND (2300)

3,150 1,470 J 596 J 65 4,210 J 1,530 403 J 20 J 27,000

13968-32-T91.xls

Page 357: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 266 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2000 2001 2001 2001 2001 2001 2002 2002 2002S-072302-JW-2000 S-072302-JW-2001 S-072302-JW-2001A S-072302-JW-2001B S-072302-JW-2001C S-072302-JW-2001D S-072402-JW-2002 S-072402-JW-2002A S-072402-JW-2002B

7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/23/2002 7/24/2002 7/24/2002 7/24/2002(0-0.33) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1)

Duplicate Duplicate

ND (480) ND (450) ND (410) ND (41) ND (42) ND (41) ND (44) ND (44) ND (41) ND (480) ND (450) ND (410) ND (41) ND (42) ND (41) ND (44) ND (44) ND (41) ND (480) ND (450) ND (410) ND (41) ND (42) ND (41) ND (44) ND (44) ND (41) ND (480) ND (450) ND (410) ND (41) ND (42) ND (41) ND (44) ND (44) ND (41)

6900 2500 1800 210 39 J 34 J 120 170 42 ND (480) ND (450) ND (410) ND (41) ND (42) ND (41) ND (44) ND (44) ND (41)

880 230 J 150 J 20 J ND (42) ND (41) 34 J 40 J 10 J

7,780 2,730 J 1,950 J 230 J 39 J 34 J 154 J 210 J 52 J

13968-32-T91.xls

Page 358: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 267 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2002 2002 2003 2003 2003 2003 2004 2004 2004S-072402-JW-2002C S-072402-JW-2002D S-072402-JW-2003 S-072402-JW-2003A S-072402-JW-2003B S-072402-JW-2003C S-072402-JW-2004 S-072402-JW-2004B S-072402-JW-2004A

7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002(1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5)

ND (41) ND (83) ND (230) ND (75) ND (40) ND (40) ND (220) ND (40) ND (40) ND (41) ND (83) ND (230) ND (75) ND (40) ND (40) ND (220) ND (40) ND (40) ND (41) ND (83) ND (230) ND (75) ND (40) ND (40) ND (220) ND (40) ND (40) ND (41) ND (83) ND (230) ND (75) ND (40) ND (40) ND (220) ND (40) ND (40)

58 350 1400 290 ND (40) 17 J 1500 180 190 ND (41) ND (83) ND (230) ND (75) ND (40) ND (40) ND (220) ND (40) ND (40)

12 J 55 J 420 66 J ND (40) ND (40) 260 36 J 33 J

70 J 405 J 1,820 356 J 0 17 J 1,760 216 J 223 J

13968-32-T91.xls

Page 359: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 268 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2004 2005 2005 2005 2005 2005 2006 2006 2006S-072402-JW-2004C S-072402-JW-2005 S-072402-JW-2005D S-072402-JW-2005A S-072402-JW-2005B S-072402-JW-2005C S-072402-JW-2006 S-072402-JW-2006A S-072402-JW-2006B

7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002(1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5)

Duplicate

ND (42) ND (84) ND (410) ND (39) ND (40) ND (40) ND (1000) ND (200) ND (41) ND (42) ND (84) ND (410) ND (39) ND (40) ND (40) ND (1000) ND (200) ND (41) ND (42) ND (84) ND (410) ND (39) ND (40) ND (40) ND (1000) ND (200) ND (41) ND (42) ND (84) ND (410) ND (39) ND (40) ND (40) ND (1000) ND (200) ND (41)

71 370 2100 67 110 60 5900 480 190 ND (42) ND (84) ND (410) ND (39) ND (40) ND (40) ND (1000) ND (200) ND (41)

13 J 63 J ND (410) 14 J 21 J 16 J 980 J 60 J 23 J

84 J 433 J 2,100 81 J 131 J 76 J 6,880 J 540 J 213 J

13968-32-T91.xls

Page 360: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 269 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2006 2007 2007 2007 2007 2007 2008 2008 2008S-072402-JW-2006C S-072402-JW-2007 S-072402-JW-2007D S-072402-JW-2007A S-072402-JW-2007B S-072402-JW-2007C S-072402-JW-2008 S-072402-JW-2008A S-072402-JW-2008B

7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002(1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5)

Duplicate

ND (40) ND (210) ND (230) ND (40) ND (42) ND (41) ND (88) ND (39) ND (40) ND (40) ND (210) ND (230) ND (40) ND (42) ND (41) ND (88) ND (39) ND (40) ND (40) ND (210) ND (230) ND (40) ND (42) ND (41) ND (88) ND (39) ND (40) ND (40) ND (210) ND (230) ND (40) ND (42) ND (41) ND (88) ND (39) ND (40)

79 890 820 39 J 35 J ND (41) 600 41 ND (40) ND (40) ND (210) ND (230) ND (40) ND (42) ND (41) ND (88) ND (39) ND (40)

9.7 J 130 J 160 J 11 J ND (42) ND (41) 240 14 J ND (40)

88.7 J 1,020 J 980 J 50 J 35 J 0 840 55 J 0

13968-32-T91.xls

Page 361: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 270 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2008 2009 2009 2009 2009 2009 2010 2010 2010S-072402-JW-2008C S-072402-JW-2009 S-072402-JW-2009D S-072402-JW-2009A S-072402-JW-2009B S-072402-JW-2009C S-072402-JW-2010 S-072402-JW-2010A S-072402-JW-2010B

7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002(1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5)

Duplicate

ND (42) ND (400) ND (200) ND (39) ND (40) ND (41) ND (400) ND (190) ND (40) ND (42) ND (400) ND (200) ND (39) ND (40) ND (41) ND (400) ND (190) ND (40) ND (42) ND (400) ND (200) ND (39) ND (40) ND (41) ND (400) ND (190) ND (40) ND (42) ND (400) ND (200) ND (39) ND (40) ND (41) ND (400) ND (190) ND (40) ND (42) 960 980 130 36 J ND (41) 1600 330 58 ND (42) ND (400) ND (200) ND (39) ND (40) ND (41) ND (400) ND (190) ND (40) ND (42) 310 J 350 38 J ND (40) ND (41) 330 J 84 J 12 J

0 1,270 J 1,330 168 J 36 J 0 1,930 J 414 J 70 J

13968-32-T91.xls

Page 362: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 271 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2010 2011 2011 2011 2011 2012 2012 2012 2012S-072402-JW-2010C S-072402-JW-2011 S-072402-JW-2011A S-072402-JW-2011B S-072402-JW-2011C S-072402-JW-2012 S-072402-JW-2012A S-072402-JW-2012B S-072402-JW-2012C

7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002(1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2)

ND (41) ND (200) ND (40) ND (40) ND (40) UJ ND (850) ND (39) ND (410) ND (39) ND (41) ND (200) ND (40) ND (40) ND (40) UJ ND (850) ND (39) ND (410) ND (39) ND (41) ND (200) ND (40) ND (40) ND (40) UJ ND (850) ND (39) ND (410) ND (39) ND (41) ND (200) ND (40) ND (40) ND (40) UJ ND (850) ND (39) ND (410) ND (39)

45 1200 ND (40) 28 J 29 J 4100 170 1800 71 ND (41) ND (200) ND (40) ND (40) ND (40) UJ ND (850) ND (39) ND (410) ND (39)

9.9 J ND (200) ND (40) ND (40) ND (40) UJ ND (850) ND (39) ND (410) ND (39)

54.9 J 1,200 0 28 J 29 J 4,100 170 1,800 71

13968-32-T91.xls

Page 363: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 272 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2013 2013 2013 2013 2013 2014 2015 2015 2015S-072402-JW-2013 S-072402-JW-2013A S-072402-JW-2013B S-072402-JW-2013C S-072402-JW-2013D S-072402-JW-2014 S-072402-JW-2015 S-072402-JW-2015A S-072402-JW-2015B

7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002 7/24/2002(0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5)

Duplicate

ND (420) ND (400) ND (40) ND (40) ND (41) ND (230) ND (860) ND (79) ND (40) ND (420) ND (400) ND (40) ND (40) ND (41) ND (230) ND (860) ND (79) ND (40) ND (420) ND (400) ND (40) ND (40) ND (41) ND (230) ND (860) ND (79) ND (40) ND (420) ND (400) ND (40) ND (40) ND (41) ND (230) ND (860) ND (79) ND (40)

2400 2200 280 180 36 J 1200 6800 350 ND (40) ND (420) ND (400) ND (40) ND (40) ND (41) ND (230) ND (860) ND (79) ND (40) ND (420) ND (400) ND (40) ND (40) ND (41) ND (230) ND (860) ND (79) ND (40)

2,400 2,200 280 180 36 J 1,200 6,800 350 0

13968-32-T91.xls

Page 364: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 273 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2015 2016 2016 2016 2016 2016 2017 2018 2019S-072402-JW-2015C S-072502-JW-2016 S-072502-JW-2016A S-072502-JW-2016B S-072502-JW-2016C S-072502-JW-2016D S-072502-JW-2017 S-072502-LM-2018 S-072502-JW-2019

7/24/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002(1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (40) ND (880) ND (900) ND (80) ND (82) ND (82) ND (240) ND (42) ND (43) ND (40) ND (880) ND (900) ND (80) ND (82) ND (82) ND (240) ND (42) ND (43) ND (40) ND (880) ND (900) ND (80) ND (82) ND (82) ND (240) ND (42) ND (43) ND (40) ND (880) ND (900) ND (80) ND (82) ND (82) ND (240) ND (42) ND (43)

30 J 7200 5300 500 670 330 2600 280 390 ND (40) ND (880) ND (900) ND (80) ND (82) ND (82) ND (240) ND (42) ND (43) ND (40) ND (880) ND (900) ND (80) ND (82) ND (82) 460 81 89

30 J 7,200 5,300 500 670 330 3,060 361 479

13968-32-T91.xls

Page 365: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 274 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2020 2020 2020 2020 2021S-072502-JW-2020 S-072502-JW-2020A S-072502-JW-2020B S-072502-JW-2020C S-072502-JW-2021

7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

ND (40) ND (39) ND (42) ND (42) ND (77) ND (40) ND (39) ND (42) ND (42) ND (77) ND (40) ND (39) ND (42) ND (42) ND (77) ND (40) ND (39) ND (42) ND (42) ND (77)

69 74 ND (42) ND (42) 610 ND (40) ND (39) ND (42) ND (42) ND (77) ND (40) ND (39) ND (42) ND (42) 89

69 74 0 0 699

13968-32-T91.xls

Page 366: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 275 of 314

Sample Location: 2021 2021 2021 2021 2022 2023 2024 2025 2026Sample ID: S-072502-JW-2021A S-072502-JW-2021B S-072502-JW-2021C S-072502-JW-2021D S-072502-JW-2022 S-072502-JW-2023 S-072502-JW-2024 S-072502-JW-2025 S-072502-JW-2026Sample Date: 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002Sample Depth: (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (78) ND (200) ND (40) ND (41) ND (450) ND (89) ND (220) ND (910) ND (440) Aroclor-1221 (PCB-1221) ug/Kg ND (78) ND (200) ND (40) ND (41) ND (450) ND (89) ND (220) ND (910) ND (440) Aroclor-1232 (PCB-1232) ug/Kg ND (78) ND (200) ND (40) ND (41) ND (450) ND (89) ND (220) ND (910) ND (440) Aroclor-1242 (PCB-1242) ug/Kg ND (78) ND (200) ND (40) ND (41) ND (450) ND (89) ND (220) ND (910) ND (440) Aroclor-1248 (PCB-1248) ug/Kg 780 1300 ND (40) ND (41) 3500 950 1800 13000 5400 Aroclor-1254 (PCB-1254) ug/Kg ND (78) ND (200) ND (40) ND (41) ND (450) ND (89) ND (220) ND (910) ND (440) Aroclor-1260 (PCB-1260) ug/Kg 120 130 J ND (40) ND (41) 360 J 120 190 J 880 J 490

Sum of Detected PCBs (ND=0) ug/Kg 900 1,430 J 0 0 3,860 J 1,070 1,990 J 13,880 J 5,890

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 367: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 276 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2027 2027 2027 2027 2028 2028 2029 2030 2030S-072502-JW-2027 S-072502-JW-2027A S-072502-JW-2027B S-072502-JW-2027C S-072502-LM-2028 S-072502-LM-2028A S-072502-JW-2029 S-072502-JW-2030 S-072502-JW-2030A

7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (410) ND (41) ND (41) ND (42) ND (2200) ND (2200) ND (43) ND (40) ND (79) ND (410) ND (41) ND (41) ND (42) ND (2200) ND (2200) ND (43) ND (40) ND (79) ND (410) ND (41) ND (41) ND (42) ND (2200) ND (2200) ND (43) ND (40) ND (79) ND (410) ND (41) ND (41) ND (42) ND (2200) ND (2200) ND (43) ND (40) ND (79)

4500 270 40 J ND (42) 9500 9000 210 540 870 ND (410) ND (41) ND (41) ND (42) ND (2200) ND (2200) ND (43) ND (40) ND (79)

370 J ND (41) ND (41) ND (42) ND (2200) ND (2200) 56 110 110

4,870 J 270 40 J 0 9,500 9,000 266 650 980

13968-32-T91.xls

Page 368: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 277 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2030 2030 2030 2031 2031 2031 2031 2032 2032S-072502-JW-2030B S-072502-JW-2030C S-072502-JW-2030D S-072502-JW-2031 S-072502-JW-2031A S-072502-JW-2031B S-072502-JW-2031C S-072502-JW-2032 S-072502-JW-2032A

7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-1.67) (0-0.33) (0.33-1)

ND (79) ND (41) ND (41) ND (400) ND (400) ND (200) ND (38) ND (3900) ND (370) ND (79) ND (41) ND (41) ND (400) ND (400) ND (200) ND (38) ND (3900) ND (370) ND (79) ND (41) ND (41) ND (400) ND (400) ND (200) ND (38) ND (3900) ND (370) ND (79) ND (41) ND (41) ND (400) ND (400) ND (200) ND (38) ND (3900) ND (370)

870 33 J ND (41) 4300 3000 540 64 14000 1800 ND (79) ND (41) ND (41) ND (400) ND (400) ND (200) ND (38) ND (3900) ND (370)

100 ND (41) ND (41) 460 230 J 70 J 10 J 1200 J 190 J

970 33 J 0 4,760 3,230 J 610 J 74 J 15,200 J 1,990 J

13968-32-T91.xls

Page 369: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 278 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2032 2032 2033 2033 2034 2034 2034 2034 2034S-072502-JW-2032B S-072502-JW-2032C S-072502-JW-2033 S-072502-JW-2033A S-072502-JW-2034 S-072502-JW-2034A S-072502-JW-2034B S-072502-JW-2034C S-072502-JW-2034D

7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002 7/25/2002(1-1.5) (1.5-2) (0-0.33) (0.33-1) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2)

Duplicate

ND (190) ND (36) ND (410) ND (420) ND (190) ND (39) ND (76) ND (37) ND (37) ND (190) ND (36) ND (410) ND (420) ND (190) ND (39) ND (76) ND (37) ND (37) ND (190) ND (36) ND (410) ND (420) ND (190) ND (39) ND (76) ND (37) ND (37) ND (190) ND (36) ND (410) ND (420) ND (190) ND (39) ND (76) ND (37) ND (37)

280 230 3300 630 950 590 880 140 ND (37) ND (190) ND (36) ND (410) ND (420) ND (190) ND (39) ND (76) ND (37) ND (37) ND (190) 23 J ND (410) ND (420) ND (190) 93 82 ND (37) ND (37)

280 253 J 3,300 630 950 683 962 140 0

13968-32-T91.xls

Page 370: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 279 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2035 2035 2035 2036 2036 2036 2036 2037 2037S-072602-JW-2035 S-072602-JW-2035A S-072602-JW-2035B S-072602-JW-2036 S-072602-JW-2036A S-072602-JW-2036B S-072602-JW-2036C S-072602-JW-2037 S-072602-JW-2037A

7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002(0-0.33) (0.33-1) (1-1.5) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33)

Duplicate

ND (1900) ND (390) ND (36) ND (4400) ND (2000) ND (760) ND (390) ND (1900) ND (3800) ND (1900) ND (390) ND (36) ND (4400) ND (2000) ND (760) ND (390) ND (1900) ND (3800) ND (1900) ND (390) ND (36) ND (4400) ND (2000) ND (760) ND (390) ND (1900) ND (3800) ND (1900) ND (390) ND (36) ND (4400) ND (2000) ND (760) ND (390) ND (1900) ND (3800)

14000 1200 130 50000 15000 4900 2400 15000 28000 ND (1900) ND (390) ND (36) ND (4400) ND (2000) ND (760) ND (390) ND (1900) ND (3800) ND (1900) ND (390) ND (36) ND (4400) ND (2000) ND (760) ND (390) ND (1900) ND (3800)

14,000 1,200 130 50,000 15,000 4,900 2,400 15,000 28,000

13968-32-T91.xls

Page 371: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 280 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2037 2037 2037 2038 2038 2038 2038 2038 2039S-072602-JW-2037B S-072602-JW-2037C S-072602-JW-2037D S-072602-JW-2038 S-072602-JW-2038A S-072602-JW-2038B S-072602-JW-2038C S-072602-JW-2038D S-072602-JW-2039

7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (1800) ND (360) ND (180) ND (4000) ND (2100) ND (390) ND (390) ND (190) ND (4100) ND (1800) ND (360) ND (180) ND (4000) ND (2100) ND (390) ND (390) ND (190) ND (4100) ND (1800) ND (360) ND (180) ND (4000) ND (2100) ND (390) ND (390) ND (190) ND (4100) ND (1800) ND (360) ND (180) ND (4000) ND (2100) ND (390) ND (390) ND (190) ND (4100)

14000 2800 740 30000 19000 2500 3000 940 21000 ND (1800) ND (360) ND (180) ND (4000) ND (2100) ND (390) ND (390) ND (190) ND (4100) ND (1800) ND (360) ND (180) ND (4000) ND (2100) ND (390) ND (390) ND (190) ND (4100)

14,000 2,800 740 30,000 19,000 2,500 3,000 940 21,000

13968-32-T91.xls

Page 372: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 281 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2039 2039 2039 2040 2040 2040 2040 2041 2041S-072602-JW-2039A S-072602-JW-2039B S-072602-JW-2039C S-072602-JW-2040 S-072602-JW-2040A S-072602-JW-2040B S-072602-JW-2040C S-072602-JW-2041 S-072602-JW-2041D

7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33)

Duplicate

ND (390) ND (44) ND (45) ND (20000) ND (38000) ND (4000) ND (410) ND (19000) ND (19000) ND (390) ND (44) ND (45) ND (20000) ND (38000) ND (4000) ND (410) ND (19000) ND (19000) ND (390) ND (44) ND (45) ND (20000) ND (38000) ND (4000) ND (410) ND (19000) ND (19000) ND (390) ND (44) ND (45) ND (20000) ND (38000) ND (4000) ND (410) ND (19000) ND (19000)

2800 170 ND (45) 67000 250000 18000 1700 140000 130000 ND (390) ND (44) ND (45) ND (20000) ND (38000) ND (4000) ND (410) ND (19000) ND (19000) ND (390) ND (44) ND (45) ND (20000) ND (38000) ND (4000) ND (410) ND (19000) ND (19000)

2,800 170 0 67,000 250,000 18,000 1,700 140,000 130,000

13968-32-T91.xls

Page 373: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 282 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2041 2041 2041 2042 2042 2042 2042 2042 2043S-072602-JW-2041A S-072602-JW-2041B S-072602-JW-2041C S-072602-JW-2042 S-072602-JW-2042A S-072602-JW-2042B S-072602-JW-2042C S-072602-JW-2042D S-072602-JW-2043

7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (370) ND (3700) ND (390) ND (21000) ND (22000) ND (39000) ND (380) ND (400) ND (19000) ND (370) ND (3700) ND (390) ND (21000) ND (22000) ND (39000) ND (380) ND (400) ND (19000) ND (370) ND (3700) ND (390) ND (21000) ND (22000) ND (39000) ND (380) ND (400) ND (19000) ND (370) ND (3700) ND (390) ND (21000) ND (22000) ND (39000) ND (380) ND (400) ND (19000)

2600 11000 2900 100000 120000 300000 1400 550 63000 ND (370) ND (3700) ND (390) ND (21000) ND (22000) ND (39000) ND (380) ND (400) ND (19000) ND (370) ND (3700) ND (390) 5900 J ND (22000) 26000 J ND (380) ND (400) ND (19000)

2,600 11,000 2,900 105,900 J 120,000 326,000 J 1,400 550 63,000

13968-32-T91.xls

Page 374: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 283 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2043 2043 2043 2044 2044 2044 2044 2045 2046S-072602-JW-2043A S-072602-JW-2043B S-072602-JW-2043C S-072602-JW-2044 S-072602-JW-2044A S-072602-JW-2044B S-072602-JW-2044C S-072602-JW-2045 S-072602-JW-2046

7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002 7/26/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33)

ND (1900) ND (1900) ND (370) ND (8400) ND (8000) ND (2100) ND (400) ND (83) ND (480) ND (1900) ND (1900) ND (370) ND (8400) ND (8000) ND (2100) ND (400) ND (83) ND (480) ND (1900) ND (1900) ND (370) ND (8400) ND (8000) ND (2100) ND (400) ND (83) ND (480) ND (1900) ND (1900) ND (370) ND (8400) ND (8000) ND (2100) ND (400) ND (83) ND (480)

10000 11000 580 50000 29000 6200 630 700 5600 ND (1900) ND (1900) ND (370) ND (8400) ND (8000) ND (2100) ND (400) ND (83) ND (480) ND (1900) ND (1900) ND (370) ND (8400) ND (8000) ND (2100) ND (400) 110 ND (480)

10,000 11,000 580 50,000 29,000 6,200 630 810 5,600

13968-32-T91.xls

Page 375: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 284 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2046 2047 2047 2047 2047 2048 2048 2048 2048S-072602-JW-2046A S-072902-JW-2047 S-072902-JW-2047A S-072902-JW-2047B S-072902-JW-2047C S-072902-JW-2048 S-072902-JW-2048A S-072902-JW-2048B S-072902-JW-2048C

7/26/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002(0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5)

Duplicate Duplicate

ND (960) ND (420) ND (4200) ND (4500) ND (420) ND (4100) ND (4000) ND (2000) ND (990) ND (960) ND (420) ND (4200) ND (4500) ND (420) ND (4100) ND (4000) ND (2000) ND (990) ND (960) ND (420) ND (4200) ND (4500) ND (420) ND (4100) ND (4000) ND (2000) ND (990) ND (960) ND (420) ND (4200) ND (4500) ND (420) ND (4100) ND (4000) ND (2000) ND (990)

5600 2800 26000 58000 2000 16000 16000 14000 8100 ND (960) ND (420) ND (4200) ND (4500) ND (420) ND (4100) ND (4000) ND (2000) ND (990) ND (960) ND (420) ND (4200) ND (4500) ND (420) ND (4100) ND (4000) ND (2000) 710 J

5,600 2,800 26,000 58,000 2,000 16,000 16,000 14,000 8,810 J

13968-32-T91.xls

Page 376: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 285 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2048 2049 2049 2049 2049 2050 2050 2050 2050S-072902-JW-2048D S-072902-JW-2049 S-072902-JW-2049A S-072902-JW-2049B S-072902-JW-2049C S-072902-BT-2050 S-072902-BT-2050D S-072902-BT-2050A S-072902-BT-2050B

7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002(1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5)

Duplicate

ND (500) ND (960) ND (2300) ND (2400) ND (5100) ND (40) ND (41) ND (40) ND (42) ND (500) ND (960) ND (2300) ND (2400) ND (5100) ND (40) ND (41) ND (40) ND (42) ND (500) ND (960) ND (2300) ND (2400) ND (5100) ND (40) ND (41) ND (40) ND (42)

1400 ND (960) ND (2300) 7700 30000 ND (40) ND (41) ND (40) ND (42) ND (500) 6600 25000 ND (2400) ND (5100) ND (40) ND (41) ND (40) ND (42) ND (500) ND (960) ND (2300) ND (2400) ND (5100) ND (40) ND (41) ND (40) ND (42) ND (500) ND (960) ND (2300) ND (2400) ND (5100) ND (40) ND (41) ND (40) ND (42)

1,400 6,600 25,000 7,700 30,000 0 0 0 0

13968-32-T91.xls

Page 377: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 286 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2050 2051 2051 2051 2051 2052 2052 2052 2052S-072902-BT-2050C S-072902-BT-2051 S-072902-BT-2051A S-072902-BT-2051B S-072902-BT-2051C S-072902-BT-2052 S-072902-BT-2052A S-072902-BT-2052B S-072902-BT-2052C

7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/29/2002(1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2)

ND (42) ND (440) ND (420) ND (39) ND (40) ND (1000) ND (2300) ND (200) ND (41) ND (42) ND (440) ND (420) ND (39) ND (40) ND (1000) ND (2300) ND (200) ND (41) ND (42) ND (440) ND (420) ND (39) ND (40) ND (1000) ND (2300) ND (200) ND (41) ND (42) ND (440) ND (420) ND (39) ND (40) ND (1000) ND (2300) ND (200) ND (41)

22 J 1300 1900 ND (39) ND (40) 7900 11000 1500 290 ND (42) ND (440) ND (420) ND (39) 26 J ND (1000) ND (2300) ND (200) ND (41) ND (42) ND (440) ND (420) ND (39) ND (40) ND (1000) ND (2300) ND (200) ND (41)

22 J 1,300 1,900 0 26 J 7,900 11,000 1,500 290

13968-32-T91.xls

Page 378: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 287 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2053 2053 2053 2053 2054 2054 2054 2054 2054S-073002-LM-2053 S-073002-LM-2053A S-073002-LM-2053B S-073002-LM-2053C S-073002-LM-2054 S-073002-LM-2054A S-073002-LM-2054B S-073002-LM-2054C S-073002-LM-2054D

7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2)

Duplicate

ND (4300) ND (21000) ND (800) ND (200) ND (4400) ND (4500) ND (8600) ND (400) ND (83) ND (4300) ND (21000) ND (800) ND (200) ND (4400) ND (4500) ND (8600) ND (400) ND (83) ND (4300) ND (21000) ND (800) ND (200) ND (4400) ND (4500) ND (8600) ND (400) ND (83) ND (4300) ND (21000) ND (800) ND (200) ND (4400) ND (4500) ND (8600) ND (400) ND (83)

26000 140000 6400 1000 27000 30000 81000 1500 300 ND (4300) ND (21000) ND (800) ND (200) ND (4400) ND (4500) ND (8600) ND (400) ND (83) ND (4300) ND (21000) ND (800) ND (200) ND (4400) ND (4500) ND (8600) ND (400) ND (83)

26,000 140,000 6,400 1,000 27,000 30,000 81,000 1,500 300

13968-32-T91.xls

Page 379: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 288 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2055 2055 2055 2055 2056 2056 2056 2056 2057S-073002-LM-2055 S-073002-LM-2055A S-073002-LM-2055B S-073002-LM-2055C S-073002-LM-2056 S-073002-LM-2056A S-073002-LM-2056B S-073002-LM-2056C S-073002-LM-2057

7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

ND (2100) ND (790) ND (40) ND (83) ND (200) ND (200) ND (200) ND (41) ND (4700) ND (2100) ND (790) ND (40) ND (83) ND (200) ND (200) ND (200) ND (41) ND (4700) ND (2100) ND (790) ND (40) ND (83) ND (200) ND (200) ND (200) ND (41) ND (4700) ND (2100) ND (790) ND (40) ND (83) ND (200) ND (200) ND (200) ND (41) ND (4700)

8400 5200 150 480 720 880 600 180 48000 ND (2100) ND (790) ND (40) ND (83) ND (200) ND (200) ND (200) ND (41) ND (4700) ND (2100) 670 J ND (40) ND (83) ND (200) ND (200) ND (200) ND (41) ND (4700)

8,400 5,870 J 150 480 720 880 600 180 48,000

13968-32-T91.xls

Page 380: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 289 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2057 2058 2059 2060 2061 2061 2061 2061 2062S-073002-LM-2057A S-073002-LM-2058 S-073002-LM-2059 S-073002-LM-2060 S-073002-LM-2061 S-073002-LM-2061A S-073002-LM-2061B S-073002-LM-2061C S-073002-LM-2062

7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (4800) ND (8800) ND (8000) ND (4600) ND (38) ND (36) ND (35) ND (36) ND (27000) ND (4800) ND (8800) ND (8000) ND (4600) ND (38) ND (36) ND (35) ND (36) ND (27000) ND (4800) ND (8800) ND (8000) ND (4600) ND (38) ND (36) ND (35) ND (36) ND (27000) ND (4800) ND (8800) ND (8000) ND (4600) ND (38) ND (36) ND (35) ND (36) ND (27000)

45000 73000 61000 48000 260 ND (36) ND (35) 35 J 210000 ND (4800) ND (8800) ND (8000) ND (4600) ND (38) ND (36) ND (35) ND (36) ND (27000) ND (4800) ND (8800) ND (8000) ND (4600) 64 ND (36) ND (35) ND (36) ND (27000)

45,000 73,000 61,000 48,000 324 0 0 35 J 210,000

13968-32-T91.xls

Page 381: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 290 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2062 2062 2062 2062 2063 2063 2063 2063 2063S-073002-LM-2062A S-073002-LM-2062B S-073002-LM-2062C S-073002-LM-2062D S-073002-LM-2063 S-073002-LM-2063A S-073002-LM-2063B S-073002-LM-2063C S-073002-LM-2063D

7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (2-3)

Duplicate

ND (27000) ND (8800) ND (48000) ND (48000) ND (10000) ND (430) ND (870) ND (220) ND (430) ND (27000) ND (8800) ND (48000) ND (48000) ND (10000) ND (430) ND (870) ND (220) ND (430) ND (27000) ND (8800) ND (48000) ND (48000) ND (10000) ND (430) ND (870) ND (220) ND (430) ND (27000) 68000 340000 190000 ND (10000) ND (430) ND (870) ND (220) ND (430)

190000 ND (8800) ND (48000) ND (48000) 150000 4100 5000 800 2800 ND (27000) ND (8800) ND (48000) ND (48000) ND (10000) ND (430) ND (870) ND (220) ND (430) ND (27000) ND (8800) ND (48000) ND (48000) ND (10000) ND (430) ND (870) ND (220) ND (430)

190,000 68,000 340,000 190,000 150,000 4,100 5,000 800 2,800

13968-32-T91.xls

Page 382: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 291 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2063 2064 2064 2064 2064 2064 2065 2065 2065S-073002-LM-2063E S-073002-LM-2064 S-073002-LM-2064D S-073002-LM-2064A S-073002-LM-2064B S-073002-LM-2064C S-073002-LM-2065 S-073002-LM-2065D S-073002-LM-2065A

7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002(3-4) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1)

Duplicate Duplicate

ND (87) ND (43) UJ ND (41) UJ ND (39) ND (41) ND (40) ND (44) ND (43) ND (42) ND (87) ND (43) UJ ND (41) UJ ND (39) ND (41) ND (40) ND (44) ND (43) ND (42) ND (87) ND (43) UJ ND (41) UJ ND (39) ND (41) ND (40) ND (44) ND (43) ND (42) ND (87) ND (43) UJ ND (41) UJ ND (39) ND (41) ND (40) ND (44) ND (43) ND (42)

660 ND (43) UJ ND (41) UJ 16 J 24 J 10 J 18 J 14 J 15 JND (87) ND (43) ND (41) ND (39) ND (41) ND (40) ND (44) ND (43) ND (42) ND (87) ND (43) ND (41) ND (39) ND (41) ND (40) ND (44) ND (43) ND (42)

660 0 0 16 J 24 J 10 J 18 J 14 J 15 J

13968-32-T91.xls

Page 383: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 292 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2065 2065 2066 2066 2066 2067 2067 2067 2068S-073002-LM-2065B S-073002-LM-2065C S-073102-BT-2066 S-073102-BT-2066A S-073102-BT-2066B S-073102-BT-2067 S-073102-BT-2067A S-073102-BT-2067B S-073102-BT-2068

7/30/2002 7/30/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002(1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (0-0.33) (0-0.33) (0.33-1) (0-0.33)

Duplicate

ND (40) ND (41) ND (1900) ND (8000) ND (390) ND (3900) ND (3900) R ND (1900) ND (40) ND (41) ND (1900) ND (8000) ND (390) ND (3900) ND (3900) R ND (1900) ND (40) ND (41) ND (1900) ND (8000) ND (390) ND (3900) ND (3900) R ND (1900) ND (40) ND (41) ND (1900) ND (8000) ND (390) ND (3900) ND (3900) R ND (1900) ND (40) ND (41) 15000 63000 2000 41000 37000 550 J 9500 ND (40) ND (41) ND (1900) ND (8000) ND (390) ND (3900) ND (3900) R ND (1900) ND (40) ND (41) ND (1900) ND (8000) ND (390) ND (3900) ND (3900) R ND (1900)

0 0 15,000 63,000 2,000 41,000 37,000 550 J 9,500

13968-32-T91.xls

Page 384: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 293 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2068 2069 2069 2069 2070 2070 2070 2070 2070S-073102-BT-2068A S-073102-BT-2069 S-073102-BT-2069A S-073102-BT-2069B S-073102-BT-2070 S-073102-BT-2070A S-073102-BT-2070B S-073102-BT-2070C S-073102-BT-2070D

7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002(0.33-1) (0-0.33) (0-0.33) (0.33-1) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2)

Duplicate Duplicate

ND (75) ND (1900) ND (1900) ND (390) ND (82) ND (210) ND (40) ND (43) ND (42) ND (75) ND (1900) ND (1900) ND (390) ND (82) ND (210) ND (40) ND (43) ND (42) ND (75) ND (1900) ND (1900) ND (390) ND (82) ND (210) ND (40) ND (43) ND (42) ND (75) ND (1900) ND (1900) ND (390) ND (82) ND (210) ND (40) ND (43) ND (42)

480 9000 12000 1600 320 540 23 J 71 ND (42) ND (75) ND (1900) ND (1900) ND (390) ND (82) ND (210) ND (40) ND (43) ND (42)

39 J 2000 2700 330 J 180 250 11 J 27 J ND (42)

519 J 11,000 14,700 1,930 J 500 790 34 J 98 J 0

13968-32-T91.xls

Page 385: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 294 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2071 2071 2071 2071 2072 2072 2072 2072 2073S-073102-BT-2071 S-073102-BT-2071A S-073102-BT-2071B S-073102-BT-2071C S-073102-BT-2072 S-073102-BT-2072A S-073102-BT-2072B S-073102-BT-2072C S-073102-BT-2073

7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002(0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

ND (1800) ND (1800) ND (1800) ND (20000) ND (3600) ND (360000) ND (370000) ND (1900) ND (2000) ND (1800) ND (1800) ND (1800) ND (20000) ND (3600) ND (360000) ND (370000) ND (1900) ND (2000) ND (1800) ND (1800) ND (1800) ND (20000) ND (3600) ND (360000) ND (370000) ND (1900) ND (2000) ND (1800) ND (1800) ND (1800) ND (20000) ND (3600) ND (360000) ND (370000) ND (1900) ND (2000)

12000 14000 13000 120000 17000 1100000 820000 19000 13000 ND (1800) ND (1800) ND (1800) ND (20000) ND (3600) ND (360000) ND (370000) ND (1900) ND (2000)

2500 2700 2300 26000 3500 J 270000 J 190000 J 3800 1100 J

14,500 16,700 15,300 146,000 20,500 J 1,370,000 J 1,010,000 J 22,800 14,100 J

13968-32-T91.xls

Page 386: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 295 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2073 2073 2074 2074 2074 2074 2075 2075 2076S-073102-BT-2073A S-073102-BT-2073B S-073102-BT-2074 S-073102-BT-2074A S-073102-BT-2074B S-073102-BT-2074C S-073102-BT-2075 S-073102-BT-2075A S-073102-BT-2076

7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002(0.33-1) (1-1.33) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (0-0.33) (0.33-1) (0-0.33)

Duplicate

ND (190) ND (810) ND (3900) ND (4000) ND (740) ND (3800) ND (4100) ND (760) ND (19000) ND (190) ND (810) ND (3900) ND (4000) ND (740) ND (3800) ND (4100) ND (760) ND (19000) ND (190) ND (810) ND (3900) ND (4000) ND (740) ND (3800) ND (4100) ND (760) ND (19000) ND (190) ND (810) ND (3900) ND (4000) ND (740) ND (3800) ND (4100) ND (760) ND (19000)

1000 6900 19000 23000 5400 35000 21000 4300 230000 ND (190) ND (810) ND (3900) ND (4000) ND (740) ND (3800) ND (4100) ND (760) ND (19000)

75 J 620 J 2000 J 2300 J 530 J 2700 J 2700 J 590 J 12000 J

1,075 J 7,520 J 21,000 J 25,300 J 5,930 J 37,700 J 23,700 J 4,890 J 242,000 J

13968-32-T91.xls

Page 387: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 296 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2076 2076 2077 2077 2077 2077 2078 2078 2078S-073102-BT-2076A S-073102-BT-2076B S-080102-LM-2077 S-080102-LM-2077A S-080102-LM-2077B S-080102-LM-2077C S-080102-LM-2078 S-080102-LM-2078A S-080102-LM-2078B

7/31/2002 7/31/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002(0.33-1) (1-1.5) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1)

Duplicate

ND (750) ND (770) ND (430) ND (200) ND (41) ND (41) ND (410) ND (40) ND (400) ND (750) ND (770) ND (430) ND (200) ND (41) ND (41) ND (410) ND (40) ND (400) ND (750) ND (770) ND (430) ND (200) ND (41) ND (41) ND (410) ND (40) ND (400) ND (750) ND (770) ND (430) ND (200) ND (41) ND (41) ND (410) ND (40) ND (400)

7400 5700 1200 680 130 ND (41) ND (410) ND (40) 2100 ND (750) ND (770) ND (430) ND (200) ND (41) ND (41) 1400 ND (40) ND (400)

540 J 300 J ND (430) ND (200) ND (41) ND (41) ND (410) ND (40) ND (400)

7,940 J 6,000 J 1,200 680 130 0 1,400 0 2,100

13968-32-T91.xls

Page 388: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 297 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2078 2078 2079 2079 2079 2079 2080 2080 2080S-080102-LM-2078C S-080102-LM-2078D S-080102-LM-2079 S-080102-LM-2079A S-080102-LM-2079B S-080102-LM-2079C S-080102-LM-2080 S-080102-LM-2080A S-080102-LM-2080B

8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002(1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5)

ND (42) ND (43) ND (39) ND (39) ND (41) ND (41) ND (45) ND (45) ND (42) ND (42) ND (43) ND (39) ND (39) ND (41) ND (41) ND (45) ND (45) ND (42) ND (42) ND (43) ND (39) ND (39) ND (41) ND (41) ND (45) ND (45) ND (42) ND (42) ND (43) ND (39) ND (39) ND (41) ND (41) ND (45) ND (45) ND (42)

68 19 J 120 ND (39) ND (41) ND (41) 150 ND (45) ND (42) ND (42) ND (43) ND (39) ND (39) ND (41) ND (41) ND (45) ND (45) ND (42) ND (42) ND (43) 38 J ND (39) ND (41) ND (41) ND (45) ND (45) ND (42)

68 19 J 158 J 0 0 0 150 0 0

13968-32-T91.xls

Page 389: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 298 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2080 2081 2081 208-175 208-176 208-177 208-177 208-178 208-179S-080102-LM-2080C S-080102-LM-2081 S-080102-LM-2081A S-00-011702-LM-175 S-00-011702-LM-176 S-00-011702-LM-177 S-00-011702-LM-177A S-00-011702-LM-178 S-00-011702-LM-179

8/1/2002 8/1/2002 8/1/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002(1.5-2) (0-0.33) (0-0.33) (0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5)

Duplicate Duplicate

ND (42) ND (390) ND (390) ND (42) ND (42) ND (42) ND (41) ND (41) ND (42) ND (42) ND (390) ND (390) ND (42) ND (42) ND (42) ND (41) ND (41) ND (42) ND (42) ND (390) ND (390) ND (42) ND (42) ND (42) ND (41) ND (41) ND (42) ND (42) ND (390) ND (390) ND (42) ND (42) ND (42) ND (41) ND (41) ND (42) ND (42) 2400 2400 ND (42) ND (42) ND (42) ND (41) ND (41) ND (42) ND (42) ND (390) ND (390) ND (42) ND (42) ND (42) ND (41) ND (41) ND (42) ND (42) 280 J 300 J ND (42) ND (42) ND (42) ND (41) ND (41) ND (42)

0 2,680 J 2,700 J 0 0 0 0 0 0

13968-32-T91.xls

Page 390: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 299 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

208-180 208-181 208-182 208-183 208-184 208-185 208-186 208-187 208-188S-00-011702-LM-180 S-00-011702-LM-181 S-00-011702-LM-182 S-00-011702-LM-183 S-00-011702-LM-184 S-00-011702-LM-185 S-00-011702-LM-186 S-00-011702-LM-187 S-00-011702-LM-188

1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002 1/17/2002(0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5) (0-0.5)

ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) ND (42) ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) ND (42) ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) ND (42) ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) ND (42) ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) ND (42) ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) 150 ND (41) ND (42) ND (43) ND (42) ND (43) ND (42) ND (42) ND (42) ND (42)

0 0 0 0 0 0 0 0 150

13968-32-T91.xls

Page 391: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 300 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

208-189 2082 2083 2084 2085 2086 2087 2088 2089S-00-011702-LM-189 S-080102-LM-2082 S-080102-LM-2083 S-080102-LM-2084 S-080102-LM-2085 S-080102-LM-2086 S-080102-LM-2087 S-080102-LM-2088 S-080102-LM-2089

1/17/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002(0-0.5) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (42) ND (770) ND (200) ND (360) ND (370) ND (43) ND (54) ND (43) ND (41) ND (42) ND (770) ND (200) ND (360) ND (370) ND (43) ND (54) ND (43) ND (41) ND (42) ND (770) ND (200) ND (360) ND (370) ND (43) ND (54) ND (43) ND (41) ND (42) ND (770) ND (200) ND (360) ND (370) ND (43) ND (54) ND (43) ND (41) ND (42) 4300 1100 1400 1600 ND (43) ND (54) ND (43) ND (41) ND (42) ND (770) ND (200) ND (360) ND (370) ND (43) ND (54) 27 J ND (41) ND (42) 500 J 150 J 190 J 210 J ND (43) ND (54) ND (43) ND (41)

0 4,800 J 1,250 J 1,590 J 1,810 J 0 0 27 J 0

13968-32-T91.xls

Page 392: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 301 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2089 2089 2089 2090 2090 2090 2090 2091 2091S-080102-LM-2089A S-080102-LM-2089B S-080102-LM-2089C S-080102-LM-2090 S-080102-LM-2090A S-080102-LM-2090B S-080102-LM-2090C S-080102-LM-2091 S-080102-LM-2091A

8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/1/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33) (0.33-1)

ND (40) ND (40) ND (40) ND (84) ND (83) ND (2100) ND (410) ND (7600) ND (780) ND (40) ND (40) ND (40) ND (84) ND (83) ND (2100) ND (410) ND (7600) ND (780) ND (40) ND (40) ND (40) ND (84) ND (83) ND (2100) ND (410) ND (7600) ND (780) ND (40) ND (40) ND (40) ND (84) ND (83) ND (2100) ND (410) ND (7600) ND (780) ND (40) ND (40) ND (40) 460 240 9400 1200 69000 4700 ND (40) ND (40) ND (40) ND (84) ND (83) ND (2100) ND (410) ND (7600) ND (780) ND (40) ND (40) ND (40) 48 J 43 J ND (2100) ND (410) 5000 J 370 J

0 0 0 508 J 283 J 9,400 1,200 74,000 J 5,070 J

13968-32-T91.xls

Page 393: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 302 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2092 2092 2092 2092 2093S-080102-LM-2092 S-080102-LM-2092A S-080102-LM-2092B S-080102-LM-2092C S-080202-BT-2093

8/1/2002 8/1/2002 8/1/2002 8/1/2002 8/2/2002(0-0.33) (0-0.33) (0.33-1) (0.33-1) (0-0.33)

Duplicate Duplicate

ND (38) ND (39) ND (38) ND (39) ND (3500) ND (38) ND (39) ND (38) ND (39) ND (3500) ND (38) ND (39) ND (38) ND (39) ND (3500) ND (38) ND (39) ND (38) ND (39) ND (3500) ND (38) ND (39) ND (38) ND (39) 33000 ND (38) ND (39) ND (38) ND (39) ND (3500) ND (38) ND (39) ND (38) ND (39) ND (3500)

0 0 0 0 33,000

13968-32-T91.xls

Page 394: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 303 of 314

Sample Location: 2094 2094 2094 2094 2095 2095 2095 2095 2096Sample ID: S-080202-BT-2094 S-080202-BT-2094B S-080202-BT-2094A S-080202-BT-2094C S-080502-JW-2095 S-080502-JW-2095A S-080502-JW-2095B S-080502-JW-2095C S-080502-JW-2096Sample Date: 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/5/2002 8/5/2002 8/5/2002 8/5/2002 8/5/2002Sample Depth: (0-0.33) (1-1.5) (0.33-1) (1.5-2) (0-0.33) (0.33-1) (1-1.5) (1.5-1.67) (0-0.33)

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (780) ND (770) ND (380) ND (190) ND (190) ND (180) ND (37) ND (38) ND (41) Aroclor-1221 (PCB-1221) ug/Kg ND (780) ND (770) ND (380) ND (190) ND (190) ND (180) ND (37) ND (38) ND (41) Aroclor-1232 (PCB-1232) ug/Kg ND (780) ND (770) ND (380) ND (190) ND (190) ND (180) ND (37) ND (38) ND (41) Aroclor-1242 (PCB-1242) ug/Kg ND (780) ND (770) ND (380) ND (190) ND (190) ND (180) ND (37) ND (38) ND (41) Aroclor-1248 (PCB-1248) ug/Kg 6700 3600 1700 730 1300 1000 ND (37) 230 ND (41) Aroclor-1254 (PCB-1254) ug/Kg ND (780) ND (770) ND (380) ND (190) ND (190) ND (180) ND (37) ND (38) 48 Aroclor-1260 (PCB-1260) ug/Kg ND (780) ND (770) ND (380) ND (190) ND (190) ND (180) ND (37) ND (38) ND (41)

Sum of Detected PCBs (ND=0) ug/Kg 6,700 3,600 1,700 730 1,300 1,000 0 230 48

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

13968-32-T91.xls

Page 395: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 304 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2096 2096 2097 2098 2098 2099 2100 2100 2100S-080502-JW-2096A S-080502-JW-2096B S-080202-MD-2097 S-080202-MD-2098 S-080202-MD-2098A S-080202-MD-2099 S-072902-JW-2100 S-072902-JW-2100A S-072902-JW-2100B

8/5/2002 8/5/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 7/29/2002 7/29/2002 7/29/2002(0-0.33) (0.33-0.75) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0.33-1)

Duplicate Duplicate Duplicate

ND (39) ND (38) ND (36) ND (35) ND (35) ND (35) ND (490) ND (400) ND (79) ND (39) ND (38) ND (36) ND (35) ND (35) ND (35) ND (490) ND (400) ND (79) ND (39) ND (38) ND (36) ND (35) ND (35) ND (35) ND (490) ND (400) ND (79) ND (39) ND (38) ND (36) ND (35) ND (35) ND (35) ND (490) ND (400) ND (79) ND (39) ND (38) 12 J ND (35) ND (35) ND (35) 4500 3200 440

42 ND (38) ND (36) ND (35) ND (35) ND (35) ND (490) ND (400) ND (79) ND (39) ND (38) ND (36) ND (35) ND (35) ND (35) ND (490) ND (400) ND (79)

42 0 12 J 0 0 0 4,500 3,200 440

13968-32-T91.xls

Page 396: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 305 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2100 2100 2100 2100 2102 2102 2102 2102 2102S-072902-JW-2100C S-072902-JW-2100D S-072902-JW-2100E S-072902-JW-2100F S-073002-JW-2102 S-073002-JW-2102A S-073002-JW-2102B S-073002-JW-2102C S-073002-JW-2102D

7/29/2002 7/29/2002 7/29/2002 7/29/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002 7/30/2002(1-1.5) (1.5-2) (2-3) (3-4) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (2-3)

ND (40) ND (40) ND (42) ND (43) ND (770) ND (75) ND (38) ND (38) ND (40) ND (40) ND (40) ND (42) ND (43) ND (770) ND (75) ND (38) ND (38) ND (40) ND (40) ND (40) ND (42) ND (43) ND (770) ND (75) ND (38) ND (38) ND (40) ND (40) ND (40) ND (42) ND (43) ND (770) ND (75) ND (38) ND (38) ND (40) ND (40) ND (40) ND (42) ND (43) 5500 340 36 J ND (38) ND (40) ND (40) ND (40) ND (42) ND (43) ND (770) ND (75) ND (38) ND (38) ND (40) ND (40) ND (40) ND (42) ND (43) ND (770) 47 J ND (38) ND (38) ND (40)

0 0 0 0 5,500 387 J 36 J 0 0

13968-32-T91.xls

Page 397: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 306 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2102 2104 2104 2104 2104 2104 2104 2104 2105S-073002-JW-2102E S-073102-JW-2104 S-073102-JW-2104A S-073102-JW-2104B S-073102-JW-2104C S-073102-JW-2104D S-073102-JW-2104E S-073102-JW-2104F S-073102-JW-2105

7/30/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002(3-4) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (2-3) (3-4) (0-0.33)

Duplicate

ND (40) ND (8800) ND (4800) ND (810) ND (40) ND (41) ND (42) ND (84) ND (8400) ND (40) ND (8800) ND (4800) ND (810) ND (40) ND (41) ND (42) ND (84) ND (8400) ND (40) ND (8800) ND (4800) ND (810) ND (40) ND (41) ND (42) ND (84) ND (8400) ND (40) ND (8800) ND (4800) ND (810) ND (40) ND (41) ND (42) ND (84) ND (8400)

9.1 J 110000 48000 4200 240 61 49 290 88000 ND (40) ND (8800) ND (4800) ND (810) ND (40) ND (41) ND (42) ND (84) ND (8400) ND (40) 6900 J 2800 J 650 J 22 J ND (41) ND (42) ND (84) 5600 J

9.1 J 116,900 J 50,800 J 4,850 J 262 J 61 49 290 93,600 J

13968-32-T91.xls

Page 398: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 307 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2105 2105 2105 2105 2105 2106 2106 2106 2106S-073102-JW-2105A S-073102-JW-2105B S-073102-JW-2105C S-073102-JW-2105D S-073102-JW-2105E S-073102-JW-2106 S-073102-JW-2106F S-073102-JW-2106A S-073102-JW-2106B

7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002 7/31/2002(0.33-1) (1-1.5) (1.5-2) (2-3) (3-4) (0-0.33) (0-0.33) (0.33-1) (1-1.5)

Duplicate

ND (3700) ND (72) ND (76) ND (190) ND (760) ND (19000) ND (4400) ND (770) ND (3800) ND (3700) ND (72) ND (76) ND (190) ND (760) ND (19000) ND (4400) ND (770) ND (3800) ND (3700) ND (72) ND (76) ND (190) ND (760) ND (19000) ND (4400) ND (770) ND (3800) ND (3700) ND (72) ND (76) ND (190) ND (760) ND (19000) ND (4400) ND (770) ND (3800)

31000 580 360 1300 6100 110000 59000 5800 36000 ND (3700) ND (72) ND (76) ND (190) ND (760) ND (19000) ND (4400) ND (770) ND (3800)

5500 46 J 30 J 72 J 390 J 7700 J 3800 J 850 1900 J

36,500 626 J 390 J 1,372 J 6,490 J 117,700 J 62,800 J 6,650 37,900 J

13968-32-T91.xls

Page 399: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 308 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2106 2106 2106 2108 2108 2108 2108 2108 2109S-073102-JW-2106C S-073102-JW-2106D S-073102-JW-2106E S-080202-BT-2108 S-080202-BT-2108A S-080202-BT-2108B S-080202-BT-2108C S-080202-BT-2108D S-080102-JW-2109

7/31/2002 7/31/2002 7/31/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/1/2002(1.5-2) (2-3) (3-4) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (190) ND (420) ND (890) ND (4000) ND (4000) ND (21000) ND (4000) ND (200) ND (4000) ND (190) ND (420) ND (890) ND (4000) ND (4000) ND (21000) ND (4000) ND (200) ND (4000) ND (190) ND (420) ND (890) ND (4000) ND (4000) ND (21000) ND (4000) ND (200) ND (4000) ND (190) ND (420) ND (890) ND (4000) ND (4000) ND (21000) ND (4000) ND (200) ND (4000)

1200 2600 6900 27000 27000 210000 28000 640 61000 ND (190) ND (420) ND (890) ND (4000) ND (4000) ND (21000) ND (4000) ND (200) ND (4000)

65 J 160 J 380 J 2900 J 3100 J 11000 J 4100 ND (200) ND (4000)

1,265 J 2,760 J 7,280 J 29,900 J 30,100 J 221,000 J 32,100 640 61,000

13968-32-T91.xls

Page 400: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 309 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2109 2109 2109 2110 2110 2110 2110 2110 2111S-080102-JW-2109A S-080102-JW-2109B S-080102-JW-2109C S-080202-BT-2110 S-080202-BT-2110A S-080202-BT-2110B S-080202-BT-2110C S-080202-BT-2110D S-080202-MD-2111

8/1/2002 8/1/2002 8/1/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002(0.33-1) (1-1.5) (1.5-2) (0-0.33) (0-0.33) (0.33-1) (1-1.5) (1.5-2) (0-0.33)

Duplicate

ND (42000) ND (810) ND (200) ND (3900) ND (2000) ND (41000) ND (3800) ND (1900) ND (37) ND (42000) ND (810) ND (200) ND (3900) ND (2000) ND (41000) ND (3800) ND (1900) ND (37) ND (42000) ND (810) ND (200) ND (3900) ND (2000) ND (41000) ND (3800) ND (1900) ND (37) ND (42000) ND (810) ND (200) ND (3900) ND (2000) ND (41000) ND (3800) ND (1900) ND (37)

300000 15000 1600 30000 18000 450000 52000 12000 6.6 JND (42000) ND (810) ND (200) ND (3900) ND (2000) ND (41000) ND (3800) ND (1900) ND (37) ND (42000) ND (810) ND (200) ND (3900) ND (2000) ND (41000) 9700 ND (1900) ND (37)

300,000 15,000 1,600 30,000 18,000 450,000 61,700 12,000 6.6 J

13968-32-T91.xls

Page 401: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 310 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2112 2113 2114 2115 2116 2116 2117 2118 2119S-080202-MD-2112 S-080202-MD-2113 S-080202-MD-2114 S-080202-MD-2115 S-080202-MD-2116 S-080202-MD-2116A S-080202-MD-2117 S-080202-MD-2118 S-080602-GS-2119

8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/2/2002 8/6/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate

ND (40) ND (37) ND (37) ND (36) ND (36) ND (36) ND (38) ND (37) ND (40) ND (40) ND (37) ND (37) ND (36) ND (36) ND (36) ND (38) ND (37) ND (40) ND (40) ND (37) ND (37) ND (36) ND (36) ND (36) ND (38) ND (37) ND (40) ND (40) ND (37) ND (37) ND (36) ND (36) ND (36) ND (38) ND (37) ND (40)

7.8 J ND (37) ND (37) ND (36) 18 J 14 J ND (38) ND (37) ND (40) ND (40) ND (37) ND (37) ND (36) ND (36) ND (36) ND (38) ND (37) ND (40) ND (40) ND (37) ND (37) ND (36) 54 44 ND (38) ND (37) ND (40)

7.8 J 0 0 0 72 J 58 J 0 0 0

13968-32-T91.xls

Page 402: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 311 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2119 2120 2121 2122 2123 2123 2124 2125 2126S-080602-GS-2119A S-080602-GS-2120 S-080602-GS-2121 S-080602-GS-2122 S-080702-JW-2123 S-080702-JW-2123A S-080702-JW-2124 S-080702-JW-2125 S-080802-JW-2126

8/6/2002 8/6/2002 8/6/2002 8/6/2002 8/7/2002 8/7/2002 8/7/2002 8/7/2002 8/8/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (40) ND (34) ND (39) ND (39) ND (2200) ND (4400) ND (420) ND (400) ND (36) ND (40) ND (34) ND (39) ND (39) ND (2200) ND (4400) ND (420) ND (400) ND (36) ND (40) ND (34) ND (39) ND (39) ND (2200) ND (4400) ND (420) ND (400) ND (36) ND (40) ND (34) ND (39) ND (39) ND (2200) ND (4400) ND (420) ND (400) ND (36) ND (40) ND (34) ND (39) ND (39) 26000 52000 2300 3000 ND (36) ND (40) ND (34) ND (39) ND (39) ND (2200) ND (4400) ND (420) ND (400) ND (36) ND (40) ND (34) ND (39) ND (39) ND (2200) ND (4400) ND (420) ND (400) ND (36)

0 0 0 0 26,000 52,000 2,300 3,000 0

13968-32-T91.xls

Page 403: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 312 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2126 2127 2128 2129 2130 2131 2131 2132 2133S-080802-JW-2126A S-080802-JW-2127 S-080802-JW-2128 S-080802-JW-2129 S-080802-JW-2130 S-082602-JW-2131 S-082602-JW-2131A S-082602-JW-2132 S-082602-JW-2133

8/8/2002 8/8/2002 8/8/2002 8/8/2002 8/8/2002 8/26/2002 8/26/2002 8/26/2002 8/26/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (36) ND (37) ND (37) ND (36) ND (38) ND (38) ND (37) ND (39) ND (36) ND (36) ND (37) ND (37) ND (36) ND (38) ND (38) ND (37) ND (39) ND (36) ND (36) ND (37) ND (37) ND (36) ND (38) ND (38) ND (37) ND (39) ND (36) ND (36) ND (37) ND (37) ND (36) ND (38) ND (38) ND (37) ND (39) ND (36) ND (36) ND (37) ND (37) ND (36) ND (38) 28 J 22 J 18 J 44 ND (36) ND (37) ND (37) ND (36) ND (38) ND (38) ND (37) ND (39) ND (36) ND (36) ND (37) ND (37) ND (36) ND (38) 12 J 12 J ND (39) 17 J

0 0 0 0 0 40 J 34 J 18 J 61 J

13968-32-T91.xls

Page 404: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 313 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2134 2135 2136 2137 2138 2139 2140 2141 2142S-082702-JW-2134 S-082702-JW-2135 S-082702-JW-2136 S-082702-JW-2137 S-082702-JW-2138 S-082702-JW-2139 S-082702-JW-2140 S-082702-JW-2141 S-082702-JW-2142

8/27/2002 8/27/2002 8/27/2002 8/27/2002 8/27/2002 8/27/2002 8/27/2002 8/27/2002 8/27/2002(0-0.02) (0-0.02) (0-0.02) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) ND (36) ND (37) ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) ND (36) ND (37) ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) ND (36) ND (37) ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) ND (36) ND (37) ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) ND (36) ND (37) ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) ND (36) 290 ND (44) ND (40) ND (45) ND (38) ND (36) ND (35) ND (39) 24 J ND (37)

0 0 0 0 0 0 0 24 J 290

13968-32-T91.xls

Page 405: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.1

ANALYTICAL RESULTSSUMMARY

SOIL SAMPLES

Page 314 of 314

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

NOTES:J = The reported laboratory result is qualified as an estimated valueU = Non-detect at associated value.UJ = The analyte was not detected above thesample reporting detection limit. The reporteddetection limit is an estimated quantity.

2142 2143 3901 3901 3902 3903 3904 COMPOSITE_1867S-082702-JW-2142A S-082702-JW-2143 S-39-020502-MD-3901 S-39-020502-MD-3901A S-39-020502-MD-3902 S-39-020502-MD-3903 S-39-020502-MD-3904 S-051702-LM-1867

8/27/2002 8/27/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 2/5/2002 5/17/2002(0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33) (0-0.33)

Duplicate Duplicate

ND (37) ND (36) ND (42) ND (44) ND (43) ND (43) ND (44) ND (440) ND (37) ND (36) ND (42) ND (44) ND (43) ND (43) ND (44) ND (440) ND (37) ND (36) ND (42) ND (44) ND (43) ND (43) ND (44) ND (440) ND (37) ND (36) ND (42) ND (44) ND (43) ND (43) ND (44) ND (440) ND (37) 26 J ND (42) ND (44) ND (43) ND (43) ND (44) ND (440)

300 ND (36) ND (42) ND (44) 57 160 200 ND (440) ND (37) 48 J ND (42) ND (44) ND (43) ND (43) ND (44) ND (440)

300 74 J 0 0 57 160 200 0

13968-32-T91.xls

Page 406: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.2

ANALYTICAL RESULTS SUMMARYPLANT TISSUE SAMPLES

Page 1 of 3

Sample Location: 001(P040) 002(P040) 002(P040) 003(P040) 004(P040)Sample ID: TP-40-022702-MD-001 TP-40-022702-MD-002 TP-40-022702-MD-002A TP-40-022702-MD-003 TP-40-022702-MD-004Sample Date: 2/27/2002 2/27/2002 2/27/2002 2/27/2002 2/27/2002Sample Depth:

Duplicate

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/Kg ND (33) ND (33) ND (33) ND (33) ND (33) Aroclor-1221 (PCB-1221) ug/Kg ND (33) ND (33) ND (33) ND (33) ND (33) Aroclor-1232 (PCB-1232) ug/Kg ND (33) ND (33) ND (33) ND (33) ND (33) Aroclor-1242 (PCB-1242) ug/Kg ND (33) ND (33) ND (33) ND (33) ND (33) Aroclor-1248 (PCB-1248) ug/Kg ND (33) 12 J 11 J 22 J ND (33) Aroclor-1254 (PCB-1254) ug/Kg ND (33) ND (33) ND (33) ND (33) ND (33) Aroclor-1260 (PCB-1260) ug/Kg ND (33) ND (33) ND (33) ND (33) ND (33)

Sum of Detected PCBs (ND=0) ug/Kg 0 12 J 11 J 22 J 0

Page 407: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.2

ANALYTICAL RESULTS SUMMARYPLANT TISSUE SAMPLES

Page 2 of 3

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

005(P040) 006(P040) 1215 Redbud Lane 1215 Redbud Lane 3901TP-40-022702-MD-005 TP-40-022702-MD-006 TP-00-JM-001(BEANS) TP-00-JM-002 TP-39-020502-MD-3901

2/27/2002 2/27/2002 3/4/2002 3/4/2002 2/5/2002

ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33)

0 0 0 0 0

Page 408: TECHNICAL MEMORANDUM PHASE II STREAM ......Worldwide Engineering, Environmental, Construction, and IT Services TECHNICAL MEMORANDUM PHASE II STREAM INVESTIGATION GM POWERTRAIN BEDFORD

TABLE 9.2

ANALYTICAL RESULTS SUMMARYPLANT TISSUE SAMPLES

Page 3 of 3

Sample Location:Sample ID:Sample Date:Sample Depth:

Parameter Unit

PCBs

Aroclor-1016 (PCB-1016) ug/KgAroclor-1221 (PCB-1221) ug/KgAroclor-1232 (PCB-1232) ug/KgAroclor-1242 (PCB-1242) ug/KgAroclor-1248 (PCB-1248) ug/KgAroclor-1254 (PCB-1254) ug/KgAroclor-1260 (PCB-1260) ug/Kg

Sum of Detected PCBs (ND=0) ug/Kg

3902 3903 3904 3905 3906 3907TP-39-020502-MD-3902 TP-39-020502-MD-3903 TP-39-020502-MD-3904 TP-39-020602-3905 TP-39-020602-3906 TP-39-020602-3907

2/5/2002 2/5/2002 2/5/2002 2/6/2002 2/6/2002 2/6/2002

ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33) ND (33)

0 0 0 0 0 0