Technical Manual - Sips Eco Panels · PDF filetechnical manual for designers the ... codes of...
Transcript of Technical Manual - Sips Eco Panels · PDF filetechnical manual for designers the ... codes of...
Technical
Manual
For Designers
The details and information in this book are for guidance purposes only and are not site
specific. Named materials must be used to conform with C.A.T.G. certification. Refer to the
relevant design manual and panel drawings for the site, which should be read in conjunction
with the approved Building Regulation drawings and must be adhered to and take priority over
standard details. FOR FIXING DETAILS REFER TO ERECTION MANUAL and
CONSTRUCTION MANUAL.
ISSUE 8
01.14
Sips Eco Panels TECHNICAL MANUAL.
CONTENTS
CM1 FOREWORD
CM5 TYPICAL EXTERNAL WALL
GENERAL INFORMATION AND GLOSSARY OF TERMS
1.00 FOUNDATIONS AND GROUND FLOOR DETAILS
CM111 DPC RELATIONSHIP WITH SCREEDED FLOOR
CM114 SOLEPLATE FIXING
CM115 JUNCTION OF INTERNAL LOAD BEARING WALL
AND FOUNDATIONS
2.00 EXTERNAL WALL DETAILS
CM211 RIM BEAM
CM212 JUNCTION OF EXTERNAL AND INTERNAL WALLS
CM218 EXTERNAL SINGLE DOOR OPENING
CM220 CLADDING DETAIL - RENDER
CM221 CLADDING DETAIL - RENDER (MOVEMENT JOINT)
CM223 EXTERNAL WALL CORNER
4.00 ROOF DETAILS
CM411 CLOSED EAVES AT WINDOW HEAD
CM414 TYPICAL RIDGE AND ATTIC DETAILS
CM415 ROOF PANEL TO PANEL CONNECTION
APPENDIX
THIS IS AN ABRIDGED VERSION OF
Sips Eco Panels
Construction Manual
THIS MANUAL IS SUPPLIED TO ALL CLIENT'S
CONTENTS
IS
SU
E 8
01.14
FOREWORD
The enclosed details are indicative of current practice and are issued for guidance
only.
Any timber frame structure manufactured and supplied by Sips eco panels will be
designed specifically for the project and will be detailed accordingly. Construction
of the timber frame must be carried out in accordance with the drawings and details
issued for construction.
Sips eco panels reserve the right to amend details as required to reflect revised
practices and changes in Building Regulations.
Whilst we believe that the contents reflect current Building Regulation requirements
it is the builder's or project manager's overall responsibility to ensure compliance
and to seek approval from Building Control Officers or other certifiers, as no
warranty is given or should be implied as to the accuracy of the information for any
specific application.
THIS MANUAL MUST BE READ IN CONJUNCTION WITH NHBC AND OTHER
GUARANTOR'S STANDARDS, ALL RELEVANT BRITISH STANDARDS AND
CODES OF PRACTICE AND ANY OTHER SPECIFICATIONS RELATIVE TO
YOUR PROJECT.
CONSTRUCTION (DESIGN & MANAGEMENT) REGULATIONS (1994)
All construction projects large and small are subject to the CDM Regulations
(1994). Essentially the regulations make the client responsible for implementing
aspects of health and safety on their site.
If the development will be for a domestic client or will be less than 30 days in
duration then the responsibility for Health and Safety is then passed onto the main
contractor. In most cases for Sips eco panels the client is the main contractor.
In all cases the client may devolve this responsibility to a CDM Planning
Supervisor, who will act on the clients behalf. Please refer to a Planning
Supervisor for advice.
FOREWORD
CM
1
IS
SU
E 8
01.14
DPC
HOLDING DOWN STRAPS SUPPLIED BY
Sips Eco Panels AND FIXED BY
BRICKWORK CONTRACTOR. SEE CM112
FINISHED
GROUND
LEVEL
OPEN PERPENDS TO
VENTILATE AND DRAIN
THE CAVITY SPACED
AT MAX. 1500mm c/c.
THE EXTERNAL WALL CONSISTS OF TWO PARTS;
THE LOADBEARING SIPS PANEL.
THE OUTER CLADDING.THIS MAY BE A HEAVYWEIGHT CLADDING SUCH AS BRICKWORK SUPPORTED
INDEPENDENTLY OFF OF FOUNDATIONS, OR A LIGHTWEIGHT CLADDING ATTACHED TO THE TIMBER
FRAME SUCH AS; RENDER, HANGING TILES OR TIMBER BOARDING. REFER TO OTHER SECTIONS OF THIS
MANUAL CM219 - CM222. SEE NOTE BELOW
SOLEPLATE - THIS PROVIDES A LEVEL
AND ACCURATE POSITIONED BASE ON
WHICH THE SUPERSTRUCTURE WILL BE FIXED,
INCLUDING THE FLOOR IN THE CASE OF
SUSPENDED TIMBER GROUND FLOORS.
IT ALSO PROVIDES A NAILING PLATE FOR
THE SIPS PANEL AND PROTECTS THE DPC.
VENTILATED
CAVITYDPC
FLOOR DPM LAPPED
LAPPED WITH DPC AND
TURNED UP TO LAP WITH
VAPOUR CONTROL LAYER.
FLOOR FINISH
SEE CM110 & CM111
VAPOUR CONTROL LAYER
(VCL SUPPLIED & FITTED BY
OTHERS BEHIND)
BREATHER
MEMBRANE
SIP PANEL
BATTENS FOR SERVICE VOID.
HELICAL TIES (NOT SUPPLIED). STAINLESS
STEEL HELIFIX TimTie 6 or SIMPSON
STRONGTIE TIMBER FRAME WALL TIES
SWT50 SPACED AT MAX 600mm c/c
HORIZONTALLY AND 450mm c/c
VERTICALLY.
THE CONSTRUCTION OF EXTERNAL WALLS MUST COMPLY WITH
APPROVED DOCUMENT B OF THE BUILDING REGULATIONS
PARTICULARLY IF THE CLADDING IS COMBUSTIBLE AND WITHIN 1M OF
THE BOUNDARY, WITH PARTICULAR ATTENTION TO PART B4
HIGHLIGHTING THE SPECIFIC MINIMUM REQUIREMENTS OF FIRE
RESISTANCE.THIS INCLUDES OPENABLE AREAS.
FOR PLASTERBOARD
SPECIFICATION REFER TO
DRAWING CM44
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
TYPICAL
EXTERNAL WALL
IS
SU
E 8
01.14
CM
5
GROUND LEVEL
150mm BELOW
LOWEST TIMBER
MIN
.150
D.P.C.
1000m
m M
IN
IM
UM
300 M
IN
.
NO
T A
B
RIC
K C
OU
RS
E
F.F.L.
D.P.C.
MIN 225mm VENTILATED VOID
TO SUIT GROUND CONDITIONS.
Sips Eco Panels RECOMMENDS THE BRICKWORK SHOULD NOT BE
STARTED BEFORE THE SIP FRAME HAS BEEN ERECTED.
65mm SCREED ON
VAPOUR BARRIER ON
90mm INSULATION ON
D.P.M LAPPED WITH WALL
VAPOUR BARRIER ON
SUSPENDED CONCRETE SLAB
450/600mm x MINIMUM DEPTH AS SHOWN ON MASS
CONCRETE FOUNDATIONS TAKEN DOWN TO BEAR INTO
VIRGIN SUITABLE STRATUM. FOUNDATIONS ALSO TO
BE TAKEN DOWN MIN. 300mm BELOW ANY ROOT
PRESENCE.
RESTRAINT STRAPS (SUPPLIED BY (Sips Eco
Panels) TO BE FIXED AT 1200mm c/c. BUILT INTO
BRICKWORK AND SET BELOW LEAN MIX
CONCRETE CAVITY FILL (IF REQUIRED). THESE
MUST BE FITTED BY BRICKLAYER TO SUIT
BRICK COURSES. SEE CM112.
OPEN PERPENDS AT 1500mm c/c.
Sips Eco Panel .
REFER TO CM5
MIN
. 225
CLE
AR
CA
VIT
Y
D.P.C.
THIS DRAWINGS IS TO BE READ IN CONJUNCTION WITH THE BUILDING REGULATIONS NOTES AND DRAWINGS.
HOUSE SETTING OUT RELIES ON F.F.L [Finished Floor Level] = EXTERNAL D.P.C. LEVEL.
TOP OF SOLEPLATE MAY REQUIRE CUTTING OUT AT INTERNAL AND EXTERNAL DOOR POSITIONS.
NO BRICKWORK IS TO BE CONSTRUCTED BELOW DPC LEVEL (TO EXTERNAL CAVITY SKIN) UNTIL AFTER THE
TIMBER FRAME HAS BEEN ERECTED (TO ENSURE THAT A NOMINAL 50mm CAVITY IS MAINTAINED BETWEEN
TIMBER FRAME AND OUTER SKIN).
THIS DRAWING SHOWS TRADITIONAL TRENCH FILL FOUNDATIONS AND IS NOT SITE SPECIFIC. ALL GROUND
FLOORS & FOUNDATION DEPTHS/DESIGN TO BE APPROVED BY THE LOCAL BUILDING INSPECTOR AND TO SUIT
LOCAL GROUND CONDITIONS.
FOR FOUNDATION SETTING OUT REFER TO FOUNDATION LOCATION PLAN
EXTERNAL WALL
440mm x 140mm x width of wall 7N/mm2 Dense
Concrete Blocks (cut to suit finished floor depth),
Density 1950kg/m3 or similar approved on 15mm
Mortar bedding - total 155mm upstand. 155mm
concrete upstand can also be used with a GEN1
mix.' N.B. If the block wall overhangs the cavity,
the erectors must ensure the DPC is lapped over
the outside face of the coursing block to stop
water ponding on top of the overhang. It is
possible that to avoid this the block could be
flush with the floor and frame (cavity side), but a
Building Inspector may query the 6mm internal
cold bridge - this should be checked with your
Building Control and / or Insurance Inspector.
DPC RELATIONSHIP WITH
SCREEDED FLOOR
IS
SU
E 8
01.14
CM
11
1
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
45mm TREATED SW
SOLEPLATE
PANEL SECURED USING
35mm x 3.9mm COARSE
THREAD BLACK
PHOSPHATE SCREWS
OR (BZP) BRIGHT ZINC
PLATED FINISH AT
150mm c/c
AND 50mm FROM END.
EXPANDED POLYSTYRENE
INSULATING CORE.
11mm THICK
OSB OUTER
SKIN WITH
BREATHER
PAPER
EXTERNALLY.
45mm
TREATED SW
BOTTOM
PLATE
DAMP PROOF COURSE
SOLEPLATE FIXING
IS
SU
E 8
01.14
CM
11
4
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
SKIRTING BOARD
PLASTERBOARD
RIGID INSULATION
SAND AND CEMENT
DPC
(OVERLAPS DPM)
DPM
AIR
BRICK
HARDCORE
DPC/DPM LAPPED
INTERNAL
440mm x 140mm x width
of wall 7N/mm2 Dense
Concrete Blocks, Density
1950kg/m3 or similar
approved on 15mm Mortar
bedding - total 155mm
upstand. 155mm concrete
upstand can also be used
with a GEN1 mix.
STUD WALL
JUNCTION OF INTERNAL
LOADBEARING WALL
FOUNDATIONSIS
SU
E 8
01.14
CM
11
5
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
PLASTERBOARD -
REFER TO CM510
FOR SPECIFICATION.
BATTENS
ON VCL
Sips Eco Panels
RIM BEAM
PLASTERBOARD
SOUND INSULATION
SKIRTING BOARD
VERTICAL
BATTEN ON VCL
HELIFIX TIMTIE 6
OR STAINLESS
STEEL SIMPSON
STRONGTIE SWT50
TIMBER FRAME
WALL TIES
BREATHER
MEMBRANE
VAPOUR
CONTROL LAYER
FLOOR DECKING
120mm HEAD
BINDER
SERVICE VOID
Sips Eco Panels
REFER TO CM5
I-BEAM
ELEVATION
PLASTERBOARD
NOGGING
BREATHER
MEMBRANE LAPPED
TOP AND BOTTOM
AND OVER RIM BEAM
FACE OR TOP MOUNTED
HANGERS TO BE USED
WHERE SPECIFIED
READ IN CONJUNCTION
WITH CM5
LAYING 22mm FLOORING
ALL NAIL RUNS AND
EXPOSED EDGES
AROUND PERIMETER
SHOULD BE
IMMEDIATELY PAINTED
WITH EGGER D4
ADHESIVE, THIS
OPERATION MUST BE
CARRIED OUT IN DRY
CONDITIONS.
IS
SU
E 8
01.14
CM
21
1
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
RIM BEAM
VAPOUR CONTROL
LAYER AS REQUIRED
PLASTERBOARD
BREATHER
MEMBRANE
Sips Eco Panel
REFER TO CM5
PLASTERBOARD ON
BATTENS. REFER TO
CM510 FOR
SPECIFICATION
95mm x 45mm STUD
PLAN
READ IN CONJUNCTION
WITH CM5
HELIFIX TIMTIE 6
OR STAINLESS
STEEL SIMPSON
STRONGTIE
SWT50 TIMBER
FRAME WALL
TIES
JUNCTION OF EXTERNAL
AND INTERNAL WALL
IS
SU
E 8
01.14
CM
21
2
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
BOTTOM RAIL
TOP RAIL
SIP LINTEL
ELEVATION
1020
SIP
PANELS
LINTEL
THE INNER TIMBER ON BOTH
SIDES IS TO BE LEFT ON SITE
AND NOT FIXED. THIS IS FOR
CLIENT'S USE IF TIMBER DOOR
FRAMES ARE USED. THEY ARE
OMITTED IF uPVC DOOR FRAME
IS USED. THEY ARE NOT
SUPPLIED FOR OTHER DOORS.
PAS90 NAILS FIXING
45mm x 95mm TO
45mm x 120mm @
200mm c/c
35mm SCREWS FIXING PANELS TO TOP
AND BOTTOM PATES & REBATED
CRIPPLE STUDS @ 150mm c/c (STARTING
50mm IN FROM EACH END)
EXTERNAL SINGLE
DOOR OPENING
IS
SU
E 8
01.14
CM
21
8
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
BREATHER
MEMBRANE
DPC
BACKED METAL LATHE
CEMENT RENDER USUALLY IN
THREE COATS
DRAINED AND VENTILATED
CAVITY
TREATED BATTENS FIXED TO
PANEL USING 3mm SS
WOODSCREWS AT 600mm c/c.
HORIZONTAL BATTENS SHOULD
PROVIDE FOR VENTILATION AND
DRAINAGE. TOPS OF BATTENS
SHOULD ALSO SLOPE TOWARDS
THE OUTSIDE.
RENDER CAN BE APPLIED TO EXTERNAL MASONRY SKIN OF A CAVITY WALL
OR AS SHOWN ABOVE FOR SINGLE OR TWO STOREY CONSTRUCTION.
BATTENS TO BE MINIMUM 50mm UNLESS BUILDING PAPER BACKED
LATHE IS USED, IN WHICH CASE BATTENS MAY BE REDUCED TO 25mm.
ADDITIONAL HORIZONTAL COUNTER BATTENS MAY BE NECESSARY
BETWEEN THE VERTICAL BATTENS AND THE BREATHER MEMBRANE
IN SEVERELY EXPOSED AREAS TO PERMIT MORE EFFICIENT
DRAINAGE OF ANY WATER.
ADDITIONAL BATTEN MAY ALSO BE REQUIRED TO ALLOW CLADDING TO LINE
THROUGH WITH BRICKWORK BELOW.
TO AVOID INFESTATION BY INSECTS, OPENINGS TO THE CAVITY SHOULD BE
PROTECTED BY AN INSECT SCREEN.
CLADDING - RENDER
SHEET 1
IS
SU
E 8
01.14
CM
22
0
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
TREATED BATTENS FIXED TO PANEL
PROTECTED BY INSECT SCREEN.
HORIZONTAL BATTENS SHOULD
PROVIDE FOR VENTILATION AND
DRAINAGE. TOPS OF BATTENS
SHOULD ALSO SLOPE TOWARDS
THE OUTSIDE.
PROPRIETARY INTUMESCENT STRIP
WITH DRAINAGE AND VENTILATION
GRID
PROPRIETARY METAL RENDER
STOPS
MOVEMENT JOINT.
REFER TO CM32
POLYTHENE DPC TO
FACE OF BATTENS
AND DRESSED UP
BEHIND BREATHER
MEMBRANE
3mm SS
WOODSCREWS
AT 600mm c/c
CLADDING-RENDER SHEET 2
ALLOWANCE FOR
MOVEMENTIS
SU
E 8
01.14
CM
22
1
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
WALL TIE
Sips Eco Panel
PLASTERBOARD
ON BATTENS
VAPOUR CONTROL
LAYER
Sips Eco Panel
BREATHER
MEMBRANE
PLAN
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. REFER TO CM510 FOR SPECIFICATION
EXTERNAL WALL
CORNER
IS
SU
E 8
01.14
CM
22
3
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
FASCIA AND SOFFIT
SUPPORT MADE UP ON
SITE TO SUIT DESIGN
CAVITY CLOSER
WINDOW FRAME. DOOR
FRAME DETAIL SIMILAR
DIFFERENTIAL MOVEMENT
JOINT REFER TO CM522
25mm
COUNTER
BATTEN
READ IN CONJUNCTION WITH CM5. PLASTERBOARD DETAILS
OMITTED FOR CLARITY. SEE ALSO CM410. REFER TO CM311 &
510 FOR PLASTERBOARD SPECIFICATION.
CLOSED EAVES
AT WINDOW HEAD
IS
SU
E 8
01.14
CM
41
1
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
DOWNSTAND BEAM TO
SUPPORT SIPS PANELS TO
ENGINEER'S
SPECIFICATIONS.
INFILL WEDGE
READ IN CONJUNCTION WITH CM5 AND CM410. PLASTERBOARD
DETAILS OMITTED FOR CLARITY. REFER TO CM510 FOR
PLASTERBOARD SPECIFICATION.
TYPICAL EAVES
(ATTIC ROOM)
VCL
VCL
READ IN CONJUNCTION WITH CM5. PLASTERBOARD
DETAILS OMITTED FOR CLARITY. REFER TO CM311 &
510 FOR PLASTERBOARD SPECIFICATION.
Ensure VCL is continuous
to retain integrity of the
building shell.
45mm x 95mm PARTITION
TYPICAL RIDGE AND
ATTIC ROOM DETAIL
IS
SU
E 8
01.14
CM
41
4
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
4
5
45mm x 172mm x 2 TIMBER SPLINES
JOINING 2 PANELS TOGETHER.
FIXED AS SHOWN BELOW.
50
8.0 x 80mm WASHERHEAD SCREW
SIMPSON STRONG TIE CODE ESCR8.0x80 OR
6.0mm x 95mm HEADLOK @ 600mm c/c (BOTH
SIDES - STAGGERED).
3.5mm x 35mm COARSE THREAD DRYWALL
SCREWS @ 150mm c/c.
3.1mm x 90mm SMOOTH
GALVANISED NAILS AT
300mm c/c (ONE SIDE).
50
C
L
1
5
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
3
0
0
6
0
0
6
0
0
6
0
0
TIMBER SPLINES PROJECT
BEYOND PANEL AND CUT PLUMB
ON SITE BY OTHERS.
THIS DETAIL IS USED IF 90mm SPLINES ARE NOT PROVIDED.
ROOF PANEL TO PANEL
CONNECTION
IS
SU
E 8
01.14
CM
41
5
Work to written dimensions only. DO NOT SCALE. If in doubt ask.
Sips Eco Panels CONSTRUCTION MANUAL.
CONTENTS
CM410 CLOSED EAVES
CM411 CLOSED EAVES AT WINDOW HEAD
CM412 FLUSH EAVES
CM413 OPEN EAVES
CM414 TYPICAL RIDGE AND ATTIC DETAILS.
CM415 ROOF PANEL TO PANEL CONNECTION
4.00 ROOF DETAILS
CM510 PLASTERBOARD SPECIFICATION
CM511 INTERNAL DOOR LINING
CM512 METER BOX DETAIL
CM513 FLUE DETAIL
CM514 WALL HUNG BOILER DETAIL
CM515 CHIMNEY DETAIL
CM516 CHIMNEY SECTION
CM517 WATER TANK DETAIL
CM518 DRILLING CHART FOR I JOISTS
CM519 DRILLING HOLES IN I JOISTS
CM520 DRILLING HOLES IN ULTRA JOISTS
CM521 DRILLING HOLES THROUGH INTERNAL WALLS
CM522 ALLOWANCE FOR VERTICAL MOVEMENT
WHEN USING MASONRY CLADDING
CM523 SUPPORT TO HEAVY OBJECTS
EXTERNAL WORKS
CM610 TREE PROTECTION NOTES
CM611 TREE PROTECTION ZONE SHEET 1
CM612 TREE PROTECTION ZONE SHEET 2
CM613 SELF-BUILD PROGRAMME
CM1 FOREWORD
CM2 NOT USED
CM3 PARTY WALL ACT SHEET 1
CM4 PARTY WALL ACT SHEET 2
CM5 TYPICAL EXTERNAL WALL
CM6 GLOSSARY OF BUILDING TERMS SHEET 1
CM7 GLOSSARY OF BUILDING TERMS SHEET 2
CM8 SCAFFOLD DETAILS
CM9 SCAFFOLD SECTION
GENERAL INFORMATION AND GLOSSARY OF TERMS
1.00 FOUNDATIONS AND GROUND FLOOR DETAILS
CM110 DPC RELATIONSHIP WITH CHIPBOARD FLOOR
CM111 DPC RELATIONSHIP WITH SCREEDED FLOOR
CM112 RESTRAINT STRAP FIXING
CM113 WIND PORTAL FOUNDATION DETAILS
CM114 SOLEPLATE FIXING
CM115 JUNCTION OF INTERNAL LOAD BEARING WALL
AND FOUNDATIONS
CM116 MOBILITY DOOR FRAME AND SCREED
CM117 MOBILITY DOOR FRAME AND CHIPBOARD
2.00 EXTERNAL WALL DETAILS
CM210 EXTERNAL WALL AND TRUSS ROOF CEILING
CM211 RIM BEAM
CM212 JUNCTION OF EXTERNAL AND INTERNAL WALLS
CM213 DOOR AND WINDOW FIXING SHEET 1
CM214 DOOR AND WINDOW FIXINGS SHEET 2
CM215 INSTALLATION OF uPVC WINDOWS SHEET 1
CM216 INSTALLATION OF uPVC WINDOWS SHEET 2
CM217.1 PARTY WALL EDGE SEALING DETAIL1
CM217.2 PARTY WALL EDGE SEALING DETAIL2
CM217.3 PARTY WALL EDGE SEALING DETAIL3
CM218 EXTERNAL SINGLE DOOR OPENING
CM219 CLADDING DETAIL - TIMBER
CM220 CLADDING DETAIL - RENDER
CM221 CLADDING DETAIL - RENDER (MOVEMENT JOINT)
CM222 CLADDING DETAIL - TILING
CM223 EXTERNAL WALL CORNER
3.00 INTERNAL DETAILS
CM310 NOGGINGS AND PANEL CONNECTION
CM311 PLASTERBOARD FIXING DETAIL
CM312 MID FLOOR SOUND INSULATION
CM313 WALL SOUND INSULATION
CM314 JUNCTION OF LOADBEARING WALL WITH FLOOR
CM315 INTERNAL WALL TO WALL JUNCTION
CM316 NON LOADBEARING WALL AND FLOOR SHEET
CM317 WALL JUNCTION IN 4 DIRECTIONS
CM318 NON LOADBEARING WALL PARALLEL TO JOISTS
5.00 MISCELLANEOUS DETAIL
APPENDIX
IS
SU
E 8
01.14