TECHNICAL ERECTION MANUAL

60
8234 Hansen Road Houston, TX 77075 (800) 324 9992 Toll Free (713) 946 7140 (832) 553 4992 Fax TECHNICAL ERECTION MANUAL SUPER SEAM II Subject to change without notice WHIRLWINDSTEEL.COM

Transcript of TECHNICAL ERECTION MANUAL

Page 1: TECHNICAL ERECTION MANUAL

8234 Hansen RoadHouston TX 77075

(800) 324 9992 Toll Free(713) 946 7140

(832) 553 4992 Fax

TECHNICAL ERECTION MANUAL SUPER SEAM II

Subject to change without noticeWHIRLWINDSTEELCOM

PLEASE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING INSTALLATION OF THE SUPER SEAM II ROOFING SYSTEM

IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY WHIRLWIND STEEL BUILDINGS INC AND DETAILS IN THIS MANUAL PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE

IMPORTANT NOTICE

Descriptions and specifications contained herein were in effect at the time this publication was approved for printing In a continuing effort to refine and improve products Whirlwind reserves the right to discontinue products at any time or change specifications andor designs without incurring obligation To insure you have the latest information available please inquire or visit our Web Site at wwwwhirlwindsteelcom

copyWhirlwind Steel buildings Inc All Rights Reserved

(800) 324 9992 WHIRLWINDSTEELCOM SSII-3SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IITABLE CONTENTS

ROOFING SYSTEM

Features and Benefits SSII-5

ENGINEERING

Read This First SSII-6

UL 90 Construction Numbers SSII-7

24rdquo Section PropertiesLoad Tables SSII-8-9

GENERAL INFORMATION

General Description SSII-10

Product Checklist SSII-11-13

Preparatory Requirements SSII-14

Unloading SSII-15

Handling amp Storage SSII-16

ERECTION SEQUENCE

Step 1 mdashRake Support SSII-17

Step 2 mdashLow System Eave SSII-18

Step 2A ndashLow System Eave Metal Inside Closure SSII-19

Step 2B ndashHigh System Eave SSII-20

Step 2C ndashHigh System Eave Metal Inside Closure SSII-21

Step 3 mdashThermal Spacer (for high systems only) SSII-22

Step 4 mdashFirst Panel SSII-23-24

Step 5 mdashBack-Up Plate SSII-25

Step 6 mdashClip Installation SSII-26

Step 7 mdashEndlap Panel SSII-27

Step 8 mdashStandard Endlap SSII-28

Step 9 mdashRidge Panel SSII-29

Step 10 mdashSubsequent Runs Eave SSII-30

Step 11 mdashSubsequent Runs Endlap SSII-31

Step 12 mdashSubsequent Runs Ridge SSII-32

Step 13 mdashLast Panel Run SSII-33

Step 13A mdashLast Panel Run (Optional) SSII-34

Step 14-Ridge-Outside ClosureFlashing SSII-35

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-4 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

TABLE CONTENTS

SPECIAL ERECTION TECHNIQUES

Recommended Erection Practices SSII-36-37

Ridge Ventilator Installation SSII-38-39

Ridge Ventilator SSII-40

Vented Ridge SSII-41

Mid-Slope Fixed Condition SSII-42

Curb Installation SSII-43-48

Roof Curb Cross Section SSII-49

S5 Windclamp Installation SSII-50

DESIGN

TRIM DETAILS

Eave To Endlap SSII-51Ridge SSII-52Rake SSII-53Rake Parapet SSII-54High Eave Parapet SSII-55Eave SSII-56Snow Gutter SSII-57Hip SSII-58Valley SSII-59

Notes SSII-60

(800) 324 9992 WHIRLWINDSTEELCOM SSII-5SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIROOFING SYSTEM

FEATURES AND BENEFITS1 DESIGN INTEGRITY

Whirlwindrsquos Super Seam II roof system begins and ends in the high reducing the risk of leakage at the rake that can occur when finishing in the low The panel seam is sealed with a factory-applied hot-melt mastic a superior grade to mastics applied in the field

2 FLOATING ROOF The Super Seam II roof was designed to cope with the forces of expansion and contraction This is accomplished by allowing the panels to freely move up and down the roof slope Due to this design feature the system offers no diaphragm capabilities or purlin stability

3 FLOATING CLIPS The Standard floating clip allows for a total of two inches of thermal movement and is constructed from 14 gauge material The clip provides a ⅜rdquo or 1⅜rdquo clearance at the purlin to reduce water ponding on low pitch roofs This clip is an integral part of maintaining panel module

4 UL 90 RATING The Super Seam II roof system has 7 different UL 90 construction numbers each of which is available with several options

5 FIRE RESISTANCE RATINGS The roof system qualifies for use in several UL design assemblies and carries a UL ldquoClass Ardquo Fire Rating

6 SIMPLICITY No field seaming is required The panels simply snap together forming a self-locking seal

7 FLEXIBILITY Whirlwinds Super Seam II roof system offers welcome flexibility to the erector Wall covering can be erected before or after the roof is installed Panel installation is an uninterrupted procedure

8 EASE OF INSTALLATION The erector has the option to install each side of the roof separately or both sides simultaneously which greatly increases the speed and convenience of erection Being reversible end-for-end sheets do not have to be special ordered for each side of the building No field notching of panels at endlaps or ridge is required

9 FORGIVING SYSTEM The Super Seam II system design allows for the roof to be finished in the ldquohighrdquo when an out-of-square condition or other factors cause the roof to terminate up to 4rdquo out of module

10 BUILDING LENGTH Odd length footage building roofs can be terminated by field bending the panel at the rake

11 PREPUNCHED PANELS AND COMPONENTS Whirlwindrsquos prepunched system combined with self-engaging back-up plates assures panel module and speeds up roof installation

12 DURABILITY Every unpainted panel is manufactured from Acrylic Coated Galvalume your assurance of the Whirlwind commitment to quality

13 COLOR AND FINISHES Super Seam II is available in a wide variety of popular colors

Vise-Gripreg is a registered trademark of American Tool Companies Inc

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-6 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERINGCAUTION

Application and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

In order to design quote or order a Super Seam II roof system you must determine which system you need based on building width and insulation requirementsLow Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with or without

a ⅜ thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with ⅜ ⅝ or

1rdquo thermal spacers See InsulationThermal Spacer Selection Chart belowFixed systems utilize fixed clips that do not allow the roof panels to float on the substructure For this reason use fixed systems only on pre-engineered metal buildings with purlins subject to the building width restrictions outlined above Do not use fixed systems on buildings with bar joist construction wood decks or metal decksLow Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with or without ⅜

thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with ⅜ ⅝ or 1rdquo

thermal spacer See InsulationThermal Spacer Selection Chart belowThermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating cliprsquos capacity Various densities of blanket insulation may affect the installation and or the appearance of a metal roof system The installer is responsible for selecting the proper clip and thermal spacer for their conditions

INSULATIONTHERMAL SPACER SELECTION CHART

Insulation Thickness Low System High System

No Insulation ⅜rdquo Thermal Spacer Do Not Use See Low System

3rdquo Insulation Thermal Spacer Not Recommended 1rdquo Thermal Spacer Recommended

4rdquo Insulation Thermal Spacer Not Recommended ⅝rdquo Thermal Spacer Recommended

6rdquo Insulation Low System Not Recommended ⅜rdquo Thermal Spacer Recommended

CAUTIONSuper Seam II is a snap together system Use of a mechanical seaming tool on the Super Seam II system may damage panels void all warranties and will void all engineering data

WARNINGAs with all standing seam roof systems sound attenuation (example blanket insulation) should be installed between the panels and open framing such as purlins or joists to prevent ldquoroof rumblerdquo during windy conditions

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior This is especially important if the bottom of the deck is left open to the interior or in cathedral ceiling applications

A vapor retarder may be necessary to protect roofing components when high humidity is a factor The need for a vapor retarder as well as the type placement and location should be determined by an architect or engineer The following are examples of conditions that may require a vapor retarder (A) a project where outside winter temperatures below 40 degrees F are anticipated and where average winter interior relative humidity of 45 or greater is expected (B) building usages with high humidity interiors such as indoor swimming pools textile manufacturing operations food paper or other wet-process industrial plants (C) Construction elements that may release moisture after the roof is installed such as interior concrete masonry or plaster work and fuel burning heaters

THERMAL SPACER DISCLAIMERThe above thermal spacer chart is intended to be used as a general guideline only Because of the various densities of insulation currently available the manufacturer cannot guarantee that this chart will be accurate in all situations Further the manufacturer does not specifically require that the roofing contractor use thermal spacers with itrsquos Super Seam IIreg roof system However please review the following information

Although the manufacturer does not require a thermal spacer the architect or building owner maybull In certain environments the compression of the fiberglass insulation without a thermal spacer may create a thermal break which can cause condensation to form on the

purlinsjoistsbull On uninsulated buildings eliminating the thermal spacer (1) will increase ldquoroof rumblerdquo and (2) you may encounter problems holding panel modulebull When a high clip is used without a thermal spacer (1) you may encounter problems holding panel module and (2) foot traffic on the panel ribs may result in bent clipsbull Using a low clip with too much insulation or too thick a thermal spacer (1) may cause ldquopurlin readrdquo (2) may cause difficulty in properly installing the panel side laps and (3)

you may encounter problems holding panel module

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 2: TECHNICAL ERECTION MANUAL

PLEASE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING INSTALLATION OF THE SUPER SEAM II ROOFING SYSTEM

IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY WHIRLWIND STEEL BUILDINGS INC AND DETAILS IN THIS MANUAL PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE

IMPORTANT NOTICE

Descriptions and specifications contained herein were in effect at the time this publication was approved for printing In a continuing effort to refine and improve products Whirlwind reserves the right to discontinue products at any time or change specifications andor designs without incurring obligation To insure you have the latest information available please inquire or visit our Web Site at wwwwhirlwindsteelcom

copyWhirlwind Steel buildings Inc All Rights Reserved

(800) 324 9992 WHIRLWINDSTEELCOM SSII-3SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IITABLE CONTENTS

ROOFING SYSTEM

Features and Benefits SSII-5

ENGINEERING

Read This First SSII-6

UL 90 Construction Numbers SSII-7

24rdquo Section PropertiesLoad Tables SSII-8-9

GENERAL INFORMATION

General Description SSII-10

Product Checklist SSII-11-13

Preparatory Requirements SSII-14

Unloading SSII-15

Handling amp Storage SSII-16

ERECTION SEQUENCE

Step 1 mdashRake Support SSII-17

Step 2 mdashLow System Eave SSII-18

Step 2A ndashLow System Eave Metal Inside Closure SSII-19

Step 2B ndashHigh System Eave SSII-20

Step 2C ndashHigh System Eave Metal Inside Closure SSII-21

Step 3 mdashThermal Spacer (for high systems only) SSII-22

Step 4 mdashFirst Panel SSII-23-24

Step 5 mdashBack-Up Plate SSII-25

Step 6 mdashClip Installation SSII-26

Step 7 mdashEndlap Panel SSII-27

Step 8 mdashStandard Endlap SSII-28

Step 9 mdashRidge Panel SSII-29

Step 10 mdashSubsequent Runs Eave SSII-30

Step 11 mdashSubsequent Runs Endlap SSII-31

Step 12 mdashSubsequent Runs Ridge SSII-32

Step 13 mdashLast Panel Run SSII-33

Step 13A mdashLast Panel Run (Optional) SSII-34

Step 14-Ridge-Outside ClosureFlashing SSII-35

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-4 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

TABLE CONTENTS

SPECIAL ERECTION TECHNIQUES

Recommended Erection Practices SSII-36-37

Ridge Ventilator Installation SSII-38-39

Ridge Ventilator SSII-40

Vented Ridge SSII-41

Mid-Slope Fixed Condition SSII-42

Curb Installation SSII-43-48

Roof Curb Cross Section SSII-49

S5 Windclamp Installation SSII-50

DESIGN

TRIM DETAILS

Eave To Endlap SSII-51Ridge SSII-52Rake SSII-53Rake Parapet SSII-54High Eave Parapet SSII-55Eave SSII-56Snow Gutter SSII-57Hip SSII-58Valley SSII-59

Notes SSII-60

(800) 324 9992 WHIRLWINDSTEELCOM SSII-5SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIROOFING SYSTEM

FEATURES AND BENEFITS1 DESIGN INTEGRITY

Whirlwindrsquos Super Seam II roof system begins and ends in the high reducing the risk of leakage at the rake that can occur when finishing in the low The panel seam is sealed with a factory-applied hot-melt mastic a superior grade to mastics applied in the field

2 FLOATING ROOF The Super Seam II roof was designed to cope with the forces of expansion and contraction This is accomplished by allowing the panels to freely move up and down the roof slope Due to this design feature the system offers no diaphragm capabilities or purlin stability

3 FLOATING CLIPS The Standard floating clip allows for a total of two inches of thermal movement and is constructed from 14 gauge material The clip provides a ⅜rdquo or 1⅜rdquo clearance at the purlin to reduce water ponding on low pitch roofs This clip is an integral part of maintaining panel module

4 UL 90 RATING The Super Seam II roof system has 7 different UL 90 construction numbers each of which is available with several options

5 FIRE RESISTANCE RATINGS The roof system qualifies for use in several UL design assemblies and carries a UL ldquoClass Ardquo Fire Rating

6 SIMPLICITY No field seaming is required The panels simply snap together forming a self-locking seal

7 FLEXIBILITY Whirlwinds Super Seam II roof system offers welcome flexibility to the erector Wall covering can be erected before or after the roof is installed Panel installation is an uninterrupted procedure

8 EASE OF INSTALLATION The erector has the option to install each side of the roof separately or both sides simultaneously which greatly increases the speed and convenience of erection Being reversible end-for-end sheets do not have to be special ordered for each side of the building No field notching of panels at endlaps or ridge is required

9 FORGIVING SYSTEM The Super Seam II system design allows for the roof to be finished in the ldquohighrdquo when an out-of-square condition or other factors cause the roof to terminate up to 4rdquo out of module

10 BUILDING LENGTH Odd length footage building roofs can be terminated by field bending the panel at the rake

11 PREPUNCHED PANELS AND COMPONENTS Whirlwindrsquos prepunched system combined with self-engaging back-up plates assures panel module and speeds up roof installation

12 DURABILITY Every unpainted panel is manufactured from Acrylic Coated Galvalume your assurance of the Whirlwind commitment to quality

13 COLOR AND FINISHES Super Seam II is available in a wide variety of popular colors

Vise-Gripreg is a registered trademark of American Tool Companies Inc

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-6 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERINGCAUTION

Application and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

In order to design quote or order a Super Seam II roof system you must determine which system you need based on building width and insulation requirementsLow Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with or without

a ⅜ thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with ⅜ ⅝ or

1rdquo thermal spacers See InsulationThermal Spacer Selection Chart belowFixed systems utilize fixed clips that do not allow the roof panels to float on the substructure For this reason use fixed systems only on pre-engineered metal buildings with purlins subject to the building width restrictions outlined above Do not use fixed systems on buildings with bar joist construction wood decks or metal decksLow Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with or without ⅜

thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with ⅜ ⅝ or 1rdquo

thermal spacer See InsulationThermal Spacer Selection Chart belowThermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating cliprsquos capacity Various densities of blanket insulation may affect the installation and or the appearance of a metal roof system The installer is responsible for selecting the proper clip and thermal spacer for their conditions

INSULATIONTHERMAL SPACER SELECTION CHART

Insulation Thickness Low System High System

No Insulation ⅜rdquo Thermal Spacer Do Not Use See Low System

3rdquo Insulation Thermal Spacer Not Recommended 1rdquo Thermal Spacer Recommended

4rdquo Insulation Thermal Spacer Not Recommended ⅝rdquo Thermal Spacer Recommended

6rdquo Insulation Low System Not Recommended ⅜rdquo Thermal Spacer Recommended

CAUTIONSuper Seam II is a snap together system Use of a mechanical seaming tool on the Super Seam II system may damage panels void all warranties and will void all engineering data

WARNINGAs with all standing seam roof systems sound attenuation (example blanket insulation) should be installed between the panels and open framing such as purlins or joists to prevent ldquoroof rumblerdquo during windy conditions

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior This is especially important if the bottom of the deck is left open to the interior or in cathedral ceiling applications

A vapor retarder may be necessary to protect roofing components when high humidity is a factor The need for a vapor retarder as well as the type placement and location should be determined by an architect or engineer The following are examples of conditions that may require a vapor retarder (A) a project where outside winter temperatures below 40 degrees F are anticipated and where average winter interior relative humidity of 45 or greater is expected (B) building usages with high humidity interiors such as indoor swimming pools textile manufacturing operations food paper or other wet-process industrial plants (C) Construction elements that may release moisture after the roof is installed such as interior concrete masonry or plaster work and fuel burning heaters

THERMAL SPACER DISCLAIMERThe above thermal spacer chart is intended to be used as a general guideline only Because of the various densities of insulation currently available the manufacturer cannot guarantee that this chart will be accurate in all situations Further the manufacturer does not specifically require that the roofing contractor use thermal spacers with itrsquos Super Seam IIreg roof system However please review the following information

Although the manufacturer does not require a thermal spacer the architect or building owner maybull In certain environments the compression of the fiberglass insulation without a thermal spacer may create a thermal break which can cause condensation to form on the

purlinsjoistsbull On uninsulated buildings eliminating the thermal spacer (1) will increase ldquoroof rumblerdquo and (2) you may encounter problems holding panel modulebull When a high clip is used without a thermal spacer (1) you may encounter problems holding panel module and (2) foot traffic on the panel ribs may result in bent clipsbull Using a low clip with too much insulation or too thick a thermal spacer (1) may cause ldquopurlin readrdquo (2) may cause difficulty in properly installing the panel side laps and (3)

you may encounter problems holding panel module

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 3: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-3SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IITABLE CONTENTS

ROOFING SYSTEM

Features and Benefits SSII-5

ENGINEERING

Read This First SSII-6

UL 90 Construction Numbers SSII-7

24rdquo Section PropertiesLoad Tables SSII-8-9

GENERAL INFORMATION

General Description SSII-10

Product Checklist SSII-11-13

Preparatory Requirements SSII-14

Unloading SSII-15

Handling amp Storage SSII-16

ERECTION SEQUENCE

Step 1 mdashRake Support SSII-17

Step 2 mdashLow System Eave SSII-18

Step 2A ndashLow System Eave Metal Inside Closure SSII-19

Step 2B ndashHigh System Eave SSII-20

Step 2C ndashHigh System Eave Metal Inside Closure SSII-21

Step 3 mdashThermal Spacer (for high systems only) SSII-22

Step 4 mdashFirst Panel SSII-23-24

Step 5 mdashBack-Up Plate SSII-25

Step 6 mdashClip Installation SSII-26

Step 7 mdashEndlap Panel SSII-27

Step 8 mdashStandard Endlap SSII-28

Step 9 mdashRidge Panel SSII-29

Step 10 mdashSubsequent Runs Eave SSII-30

Step 11 mdashSubsequent Runs Endlap SSII-31

Step 12 mdashSubsequent Runs Ridge SSII-32

Step 13 mdashLast Panel Run SSII-33

Step 13A mdashLast Panel Run (Optional) SSII-34

Step 14-Ridge-Outside ClosureFlashing SSII-35

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-4 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

TABLE CONTENTS

SPECIAL ERECTION TECHNIQUES

Recommended Erection Practices SSII-36-37

Ridge Ventilator Installation SSII-38-39

Ridge Ventilator SSII-40

Vented Ridge SSII-41

Mid-Slope Fixed Condition SSII-42

Curb Installation SSII-43-48

Roof Curb Cross Section SSII-49

S5 Windclamp Installation SSII-50

DESIGN

TRIM DETAILS

Eave To Endlap SSII-51Ridge SSII-52Rake SSII-53Rake Parapet SSII-54High Eave Parapet SSII-55Eave SSII-56Snow Gutter SSII-57Hip SSII-58Valley SSII-59

Notes SSII-60

(800) 324 9992 WHIRLWINDSTEELCOM SSII-5SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIROOFING SYSTEM

FEATURES AND BENEFITS1 DESIGN INTEGRITY

Whirlwindrsquos Super Seam II roof system begins and ends in the high reducing the risk of leakage at the rake that can occur when finishing in the low The panel seam is sealed with a factory-applied hot-melt mastic a superior grade to mastics applied in the field

2 FLOATING ROOF The Super Seam II roof was designed to cope with the forces of expansion and contraction This is accomplished by allowing the panels to freely move up and down the roof slope Due to this design feature the system offers no diaphragm capabilities or purlin stability

3 FLOATING CLIPS The Standard floating clip allows for a total of two inches of thermal movement and is constructed from 14 gauge material The clip provides a ⅜rdquo or 1⅜rdquo clearance at the purlin to reduce water ponding on low pitch roofs This clip is an integral part of maintaining panel module

4 UL 90 RATING The Super Seam II roof system has 7 different UL 90 construction numbers each of which is available with several options

5 FIRE RESISTANCE RATINGS The roof system qualifies for use in several UL design assemblies and carries a UL ldquoClass Ardquo Fire Rating

6 SIMPLICITY No field seaming is required The panels simply snap together forming a self-locking seal

7 FLEXIBILITY Whirlwinds Super Seam II roof system offers welcome flexibility to the erector Wall covering can be erected before or after the roof is installed Panel installation is an uninterrupted procedure

8 EASE OF INSTALLATION The erector has the option to install each side of the roof separately or both sides simultaneously which greatly increases the speed and convenience of erection Being reversible end-for-end sheets do not have to be special ordered for each side of the building No field notching of panels at endlaps or ridge is required

9 FORGIVING SYSTEM The Super Seam II system design allows for the roof to be finished in the ldquohighrdquo when an out-of-square condition or other factors cause the roof to terminate up to 4rdquo out of module

10 BUILDING LENGTH Odd length footage building roofs can be terminated by field bending the panel at the rake

11 PREPUNCHED PANELS AND COMPONENTS Whirlwindrsquos prepunched system combined with self-engaging back-up plates assures panel module and speeds up roof installation

12 DURABILITY Every unpainted panel is manufactured from Acrylic Coated Galvalume your assurance of the Whirlwind commitment to quality

13 COLOR AND FINISHES Super Seam II is available in a wide variety of popular colors

Vise-Gripreg is a registered trademark of American Tool Companies Inc

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-6 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERINGCAUTION

Application and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

In order to design quote or order a Super Seam II roof system you must determine which system you need based on building width and insulation requirementsLow Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with or without

a ⅜ thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with ⅜ ⅝ or

1rdquo thermal spacers See InsulationThermal Spacer Selection Chart belowFixed systems utilize fixed clips that do not allow the roof panels to float on the substructure For this reason use fixed systems only on pre-engineered metal buildings with purlins subject to the building width restrictions outlined above Do not use fixed systems on buildings with bar joist construction wood decks or metal decksLow Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with or without ⅜

thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with ⅜ ⅝ or 1rdquo

thermal spacer See InsulationThermal Spacer Selection Chart belowThermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating cliprsquos capacity Various densities of blanket insulation may affect the installation and or the appearance of a metal roof system The installer is responsible for selecting the proper clip and thermal spacer for their conditions

INSULATIONTHERMAL SPACER SELECTION CHART

Insulation Thickness Low System High System

No Insulation ⅜rdquo Thermal Spacer Do Not Use See Low System

3rdquo Insulation Thermal Spacer Not Recommended 1rdquo Thermal Spacer Recommended

4rdquo Insulation Thermal Spacer Not Recommended ⅝rdquo Thermal Spacer Recommended

6rdquo Insulation Low System Not Recommended ⅜rdquo Thermal Spacer Recommended

CAUTIONSuper Seam II is a snap together system Use of a mechanical seaming tool on the Super Seam II system may damage panels void all warranties and will void all engineering data

WARNINGAs with all standing seam roof systems sound attenuation (example blanket insulation) should be installed between the panels and open framing such as purlins or joists to prevent ldquoroof rumblerdquo during windy conditions

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior This is especially important if the bottom of the deck is left open to the interior or in cathedral ceiling applications

A vapor retarder may be necessary to protect roofing components when high humidity is a factor The need for a vapor retarder as well as the type placement and location should be determined by an architect or engineer The following are examples of conditions that may require a vapor retarder (A) a project where outside winter temperatures below 40 degrees F are anticipated and where average winter interior relative humidity of 45 or greater is expected (B) building usages with high humidity interiors such as indoor swimming pools textile manufacturing operations food paper or other wet-process industrial plants (C) Construction elements that may release moisture after the roof is installed such as interior concrete masonry or plaster work and fuel burning heaters

THERMAL SPACER DISCLAIMERThe above thermal spacer chart is intended to be used as a general guideline only Because of the various densities of insulation currently available the manufacturer cannot guarantee that this chart will be accurate in all situations Further the manufacturer does not specifically require that the roofing contractor use thermal spacers with itrsquos Super Seam IIreg roof system However please review the following information

Although the manufacturer does not require a thermal spacer the architect or building owner maybull In certain environments the compression of the fiberglass insulation without a thermal spacer may create a thermal break which can cause condensation to form on the

purlinsjoistsbull On uninsulated buildings eliminating the thermal spacer (1) will increase ldquoroof rumblerdquo and (2) you may encounter problems holding panel modulebull When a high clip is used without a thermal spacer (1) you may encounter problems holding panel module and (2) foot traffic on the panel ribs may result in bent clipsbull Using a low clip with too much insulation or too thick a thermal spacer (1) may cause ldquopurlin readrdquo (2) may cause difficulty in properly installing the panel side laps and (3)

you may encounter problems holding panel module

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 4: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-4 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

TABLE CONTENTS

SPECIAL ERECTION TECHNIQUES

Recommended Erection Practices SSII-36-37

Ridge Ventilator Installation SSII-38-39

Ridge Ventilator SSII-40

Vented Ridge SSII-41

Mid-Slope Fixed Condition SSII-42

Curb Installation SSII-43-48

Roof Curb Cross Section SSII-49

S5 Windclamp Installation SSII-50

DESIGN

TRIM DETAILS

Eave To Endlap SSII-51Ridge SSII-52Rake SSII-53Rake Parapet SSII-54High Eave Parapet SSII-55Eave SSII-56Snow Gutter SSII-57Hip SSII-58Valley SSII-59

Notes SSII-60

(800) 324 9992 WHIRLWINDSTEELCOM SSII-5SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIROOFING SYSTEM

FEATURES AND BENEFITS1 DESIGN INTEGRITY

Whirlwindrsquos Super Seam II roof system begins and ends in the high reducing the risk of leakage at the rake that can occur when finishing in the low The panel seam is sealed with a factory-applied hot-melt mastic a superior grade to mastics applied in the field

2 FLOATING ROOF The Super Seam II roof was designed to cope with the forces of expansion and contraction This is accomplished by allowing the panels to freely move up and down the roof slope Due to this design feature the system offers no diaphragm capabilities or purlin stability

3 FLOATING CLIPS The Standard floating clip allows for a total of two inches of thermal movement and is constructed from 14 gauge material The clip provides a ⅜rdquo or 1⅜rdquo clearance at the purlin to reduce water ponding on low pitch roofs This clip is an integral part of maintaining panel module

4 UL 90 RATING The Super Seam II roof system has 7 different UL 90 construction numbers each of which is available with several options

5 FIRE RESISTANCE RATINGS The roof system qualifies for use in several UL design assemblies and carries a UL ldquoClass Ardquo Fire Rating

6 SIMPLICITY No field seaming is required The panels simply snap together forming a self-locking seal

7 FLEXIBILITY Whirlwinds Super Seam II roof system offers welcome flexibility to the erector Wall covering can be erected before or after the roof is installed Panel installation is an uninterrupted procedure

8 EASE OF INSTALLATION The erector has the option to install each side of the roof separately or both sides simultaneously which greatly increases the speed and convenience of erection Being reversible end-for-end sheets do not have to be special ordered for each side of the building No field notching of panels at endlaps or ridge is required

9 FORGIVING SYSTEM The Super Seam II system design allows for the roof to be finished in the ldquohighrdquo when an out-of-square condition or other factors cause the roof to terminate up to 4rdquo out of module

10 BUILDING LENGTH Odd length footage building roofs can be terminated by field bending the panel at the rake

11 PREPUNCHED PANELS AND COMPONENTS Whirlwindrsquos prepunched system combined with self-engaging back-up plates assures panel module and speeds up roof installation

12 DURABILITY Every unpainted panel is manufactured from Acrylic Coated Galvalume your assurance of the Whirlwind commitment to quality

13 COLOR AND FINISHES Super Seam II is available in a wide variety of popular colors

Vise-Gripreg is a registered trademark of American Tool Companies Inc

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-6 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERINGCAUTION

Application and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

In order to design quote or order a Super Seam II roof system you must determine which system you need based on building width and insulation requirementsLow Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with or without

a ⅜ thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with ⅜ ⅝ or

1rdquo thermal spacers See InsulationThermal Spacer Selection Chart belowFixed systems utilize fixed clips that do not allow the roof panels to float on the substructure For this reason use fixed systems only on pre-engineered metal buildings with purlins subject to the building width restrictions outlined above Do not use fixed systems on buildings with bar joist construction wood decks or metal decksLow Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with or without ⅜

thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with ⅜ ⅝ or 1rdquo

thermal spacer See InsulationThermal Spacer Selection Chart belowThermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating cliprsquos capacity Various densities of blanket insulation may affect the installation and or the appearance of a metal roof system The installer is responsible for selecting the proper clip and thermal spacer for their conditions

INSULATIONTHERMAL SPACER SELECTION CHART

Insulation Thickness Low System High System

No Insulation ⅜rdquo Thermal Spacer Do Not Use See Low System

3rdquo Insulation Thermal Spacer Not Recommended 1rdquo Thermal Spacer Recommended

4rdquo Insulation Thermal Spacer Not Recommended ⅝rdquo Thermal Spacer Recommended

6rdquo Insulation Low System Not Recommended ⅜rdquo Thermal Spacer Recommended

CAUTIONSuper Seam II is a snap together system Use of a mechanical seaming tool on the Super Seam II system may damage panels void all warranties and will void all engineering data

WARNINGAs with all standing seam roof systems sound attenuation (example blanket insulation) should be installed between the panels and open framing such as purlins or joists to prevent ldquoroof rumblerdquo during windy conditions

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior This is especially important if the bottom of the deck is left open to the interior or in cathedral ceiling applications

A vapor retarder may be necessary to protect roofing components when high humidity is a factor The need for a vapor retarder as well as the type placement and location should be determined by an architect or engineer The following are examples of conditions that may require a vapor retarder (A) a project where outside winter temperatures below 40 degrees F are anticipated and where average winter interior relative humidity of 45 or greater is expected (B) building usages with high humidity interiors such as indoor swimming pools textile manufacturing operations food paper or other wet-process industrial plants (C) Construction elements that may release moisture after the roof is installed such as interior concrete masonry or plaster work and fuel burning heaters

THERMAL SPACER DISCLAIMERThe above thermal spacer chart is intended to be used as a general guideline only Because of the various densities of insulation currently available the manufacturer cannot guarantee that this chart will be accurate in all situations Further the manufacturer does not specifically require that the roofing contractor use thermal spacers with itrsquos Super Seam IIreg roof system However please review the following information

Although the manufacturer does not require a thermal spacer the architect or building owner maybull In certain environments the compression of the fiberglass insulation without a thermal spacer may create a thermal break which can cause condensation to form on the

purlinsjoistsbull On uninsulated buildings eliminating the thermal spacer (1) will increase ldquoroof rumblerdquo and (2) you may encounter problems holding panel modulebull When a high clip is used without a thermal spacer (1) you may encounter problems holding panel module and (2) foot traffic on the panel ribs may result in bent clipsbull Using a low clip with too much insulation or too thick a thermal spacer (1) may cause ldquopurlin readrdquo (2) may cause difficulty in properly installing the panel side laps and (3)

you may encounter problems holding panel module

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 5: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-5SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIROOFING SYSTEM

FEATURES AND BENEFITS1 DESIGN INTEGRITY

Whirlwindrsquos Super Seam II roof system begins and ends in the high reducing the risk of leakage at the rake that can occur when finishing in the low The panel seam is sealed with a factory-applied hot-melt mastic a superior grade to mastics applied in the field

2 FLOATING ROOF The Super Seam II roof was designed to cope with the forces of expansion and contraction This is accomplished by allowing the panels to freely move up and down the roof slope Due to this design feature the system offers no diaphragm capabilities or purlin stability

3 FLOATING CLIPS The Standard floating clip allows for a total of two inches of thermal movement and is constructed from 14 gauge material The clip provides a ⅜rdquo or 1⅜rdquo clearance at the purlin to reduce water ponding on low pitch roofs This clip is an integral part of maintaining panel module

4 UL 90 RATING The Super Seam II roof system has 7 different UL 90 construction numbers each of which is available with several options

5 FIRE RESISTANCE RATINGS The roof system qualifies for use in several UL design assemblies and carries a UL ldquoClass Ardquo Fire Rating

6 SIMPLICITY No field seaming is required The panels simply snap together forming a self-locking seal

7 FLEXIBILITY Whirlwinds Super Seam II roof system offers welcome flexibility to the erector Wall covering can be erected before or after the roof is installed Panel installation is an uninterrupted procedure

8 EASE OF INSTALLATION The erector has the option to install each side of the roof separately or both sides simultaneously which greatly increases the speed and convenience of erection Being reversible end-for-end sheets do not have to be special ordered for each side of the building No field notching of panels at endlaps or ridge is required

9 FORGIVING SYSTEM The Super Seam II system design allows for the roof to be finished in the ldquohighrdquo when an out-of-square condition or other factors cause the roof to terminate up to 4rdquo out of module

10 BUILDING LENGTH Odd length footage building roofs can be terminated by field bending the panel at the rake

11 PREPUNCHED PANELS AND COMPONENTS Whirlwindrsquos prepunched system combined with self-engaging back-up plates assures panel module and speeds up roof installation

12 DURABILITY Every unpainted panel is manufactured from Acrylic Coated Galvalume your assurance of the Whirlwind commitment to quality

13 COLOR AND FINISHES Super Seam II is available in a wide variety of popular colors

Vise-Gripreg is a registered trademark of American Tool Companies Inc

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-6 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERINGCAUTION

Application and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

In order to design quote or order a Super Seam II roof system you must determine which system you need based on building width and insulation requirementsLow Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with or without

a ⅜ thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with ⅜ ⅝ or

1rdquo thermal spacers See InsulationThermal Spacer Selection Chart belowFixed systems utilize fixed clips that do not allow the roof panels to float on the substructure For this reason use fixed systems only on pre-engineered metal buildings with purlins subject to the building width restrictions outlined above Do not use fixed systems on buildings with bar joist construction wood decks or metal decksLow Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with or without ⅜

thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with ⅜ ⅝ or 1rdquo

thermal spacer See InsulationThermal Spacer Selection Chart belowThermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating cliprsquos capacity Various densities of blanket insulation may affect the installation and or the appearance of a metal roof system The installer is responsible for selecting the proper clip and thermal spacer for their conditions

INSULATIONTHERMAL SPACER SELECTION CHART

Insulation Thickness Low System High System

No Insulation ⅜rdquo Thermal Spacer Do Not Use See Low System

3rdquo Insulation Thermal Spacer Not Recommended 1rdquo Thermal Spacer Recommended

4rdquo Insulation Thermal Spacer Not Recommended ⅝rdquo Thermal Spacer Recommended

6rdquo Insulation Low System Not Recommended ⅜rdquo Thermal Spacer Recommended

CAUTIONSuper Seam II is a snap together system Use of a mechanical seaming tool on the Super Seam II system may damage panels void all warranties and will void all engineering data

WARNINGAs with all standing seam roof systems sound attenuation (example blanket insulation) should be installed between the panels and open framing such as purlins or joists to prevent ldquoroof rumblerdquo during windy conditions

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior This is especially important if the bottom of the deck is left open to the interior or in cathedral ceiling applications

A vapor retarder may be necessary to protect roofing components when high humidity is a factor The need for a vapor retarder as well as the type placement and location should be determined by an architect or engineer The following are examples of conditions that may require a vapor retarder (A) a project where outside winter temperatures below 40 degrees F are anticipated and where average winter interior relative humidity of 45 or greater is expected (B) building usages with high humidity interiors such as indoor swimming pools textile manufacturing operations food paper or other wet-process industrial plants (C) Construction elements that may release moisture after the roof is installed such as interior concrete masonry or plaster work and fuel burning heaters

THERMAL SPACER DISCLAIMERThe above thermal spacer chart is intended to be used as a general guideline only Because of the various densities of insulation currently available the manufacturer cannot guarantee that this chart will be accurate in all situations Further the manufacturer does not specifically require that the roofing contractor use thermal spacers with itrsquos Super Seam IIreg roof system However please review the following information

Although the manufacturer does not require a thermal spacer the architect or building owner maybull In certain environments the compression of the fiberglass insulation without a thermal spacer may create a thermal break which can cause condensation to form on the

purlinsjoistsbull On uninsulated buildings eliminating the thermal spacer (1) will increase ldquoroof rumblerdquo and (2) you may encounter problems holding panel modulebull When a high clip is used without a thermal spacer (1) you may encounter problems holding panel module and (2) foot traffic on the panel ribs may result in bent clipsbull Using a low clip with too much insulation or too thick a thermal spacer (1) may cause ldquopurlin readrdquo (2) may cause difficulty in properly installing the panel side laps and (3)

you may encounter problems holding panel module

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 6: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-6 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERINGCAUTION

Application and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

In order to design quote or order a Super Seam II roof system you must determine which system you need based on building width and insulation requirementsLow Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with or without

a ⅜ thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Fixed System - Double slope buildings 200rsquo wide or less and single slope buildings 100rsquo wide or less with ⅜ ⅝ or

1rdquo thermal spacers See InsulationThermal Spacer Selection Chart belowFixed systems utilize fixed clips that do not allow the roof panels to float on the substructure For this reason use fixed systems only on pre-engineered metal buildings with purlins subject to the building width restrictions outlined above Do not use fixed systems on buildings with bar joist construction wood decks or metal decksLow Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with or without ⅜

thermal spacer See InsulationThermal Spacer Selection Chart belowHigh Floating System - Double slope buildings over 200rsquo wide or single slope buildings over 100rsquo wide with ⅜ ⅝ or 1rdquo

thermal spacer See InsulationThermal Spacer Selection Chart belowThermal calculations should be performed for each project to ensure that the thermal movement of the roof is not greater than the floating cliprsquos capacity Various densities of blanket insulation may affect the installation and or the appearance of a metal roof system The installer is responsible for selecting the proper clip and thermal spacer for their conditions

INSULATIONTHERMAL SPACER SELECTION CHART

Insulation Thickness Low System High System

No Insulation ⅜rdquo Thermal Spacer Do Not Use See Low System

3rdquo Insulation Thermal Spacer Not Recommended 1rdquo Thermal Spacer Recommended

4rdquo Insulation Thermal Spacer Not Recommended ⅝rdquo Thermal Spacer Recommended

6rdquo Insulation Low System Not Recommended ⅜rdquo Thermal Spacer Recommended

CAUTIONSuper Seam II is a snap together system Use of a mechanical seaming tool on the Super Seam II system may damage panels void all warranties and will void all engineering data

WARNINGAs with all standing seam roof systems sound attenuation (example blanket insulation) should be installed between the panels and open framing such as purlins or joists to prevent ldquoroof rumblerdquo during windy conditions

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior This is especially important if the bottom of the deck is left open to the interior or in cathedral ceiling applications

A vapor retarder may be necessary to protect roofing components when high humidity is a factor The need for a vapor retarder as well as the type placement and location should be determined by an architect or engineer The following are examples of conditions that may require a vapor retarder (A) a project where outside winter temperatures below 40 degrees F are anticipated and where average winter interior relative humidity of 45 or greater is expected (B) building usages with high humidity interiors such as indoor swimming pools textile manufacturing operations food paper or other wet-process industrial plants (C) Construction elements that may release moisture after the roof is installed such as interior concrete masonry or plaster work and fuel burning heaters

THERMAL SPACER DISCLAIMERThe above thermal spacer chart is intended to be used as a general guideline only Because of the various densities of insulation currently available the manufacturer cannot guarantee that this chart will be accurate in all situations Further the manufacturer does not specifically require that the roofing contractor use thermal spacers with itrsquos Super Seam IIreg roof system However please review the following information

Although the manufacturer does not require a thermal spacer the architect or building owner maybull In certain environments the compression of the fiberglass insulation without a thermal spacer may create a thermal break which can cause condensation to form on the

purlinsjoistsbull On uninsulated buildings eliminating the thermal spacer (1) will increase ldquoroof rumblerdquo and (2) you may encounter problems holding panel modulebull When a high clip is used without a thermal spacer (1) you may encounter problems holding panel module and (2) foot traffic on the panel ribs may result in bent clipsbull Using a low clip with too much insulation or too thick a thermal spacer (1) may cause ldquopurlin readrdquo (2) may cause difficulty in properly installing the panel side laps and (3)

you may encounter problems holding panel module

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 7: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-7SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

NOTES1 Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under ldquoTests For Uplift

Resistance of Roof Assembliesrdquo2 A detailed installation method is available for each Construction Number above and can be found in the UL Roofing

Materials and Systems Directory or at httpwwwulcom The panels must be installed in a certain manner to achieve the published results

3 The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-2634 The panel system is listed under the following Fire Resistance Design Numbers P225 P227 P230 P237 P265 P268

P508 P510 P512 P701 P711 P717 P720 P722 P726 P731 P734 P736 P801 P803 P814 P815 and P819 Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings

5 Super Seam panels carry a Class 4 rating under UL-2218 ldquoTest Standard For Impact Resistancerdquo

UNDERWRITERS LABORATORIES APPROVAL

Construction Number

Panel Width (In) Gauge

Clip Type

Clip Spacing

Substrate UL-2218 Impact Resistance

UL-263 Fire Rating

UL-580 Rating

165 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

180B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

205 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

205A 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

286 24 24 min A 5rsquo-0rdquo Plywood Class 4 Class A Class 90

308B 24 24 min A 5rsquo-0rdquo Composite System Class 4 Class A Class 90

534 24 24 min B 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

535 24 24 min A 5rsquo-0rdquo Open Framing Class 4 Class A Class 90

536 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

537 24 24 min B 5rsquo-0rdquo Composite System Class 4 Class A Class 90

541 24 26 min B 5rsquo-0rdquo Plywood Class 4 Class A Class 90

Clip type A (Sliding) B (Floating) C (Utility)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 8: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-8 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ENGINEERING

SUPER SEAM II Panel24rdquo Coverage

NOTES1 All calculations for the properties of Super Seam II panels are calculated in accordance with the 2012 edition of the

North American Specification For Design Of Cold-Formed Steel Structural Members2 Ixe is for deflection determination3 Sxe is for bending4 Maxo is allowable bending moment5 All values are for one foot of panel width

SECTION PROPERTIES

Panel Gauge

Fy(KSI)

Weight(PSF)

NEGATIVE BENDING POSITIVE BENDING

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

Ixe(IN 4FT)

Sxe(IN 3FT)

Maxo(KIP-IN)

26 50 102 01025 00694 20764 02202 00901 26987

24 50 123 01355 00951 28477 02803 01156 34612

22 50 156 01837 01332 39877 03640 01504 45020

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 9: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-9SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIENGINEERING

24 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2040 1700 1457 1275 1133 923 763

2-SPAN LIVE 2040 1700 1457 1187 938 759 628

3-SPAN LIVE 2040 1700 1457 1275 1133 949 784

4-SPAN LIVE 2040 1700 1457 1275 1094 886 732

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT

The Engineering data contained herein is for the expressed use of customers and design professionals Along with this data it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design This Specification contains the design criteria for cold-formed steel components Along with the Specification the designer should reference the most current building code applicable to the project job site in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired please contact the manufacturer

SUPER SEAM II Panel24rdquo Coverage

7rdquo

24rdquo Coverage

3rdquo26 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 1469 1224 1049 918 816 720 595

2-SPAN LIVE 1469 1224 1049 865 684 554 458

3-SPAN LIVE 1469 1224 1049 918 816 692 572

4-SPAN LIVE 1469 1224 1049 918 798 646 534

22 Gauge (Fy = 50 KSI)

SPAN TYPE LOAD TYPESPAN IN FEET

25 30 35 40 45 50 55

SINGLE LIVE 2969 2475 2121 1856 1482 1201 992

2-SPAN LIVE 2969 2475 2121 1662 1313 1063 879

3-SPAN LIVE 2969 2475 2121 1856 1641 1329 1099

4-SPAN LIVE 2969 2475 2121 1856 1532 1241 1026NOTES

1 THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT2 Strength calculations based on the 2012 AISI Standard ldquoNorth American Specification for the Design of Cold-formed Steel Structural Membersrdquo3 Allowable loads are applicable for uniform loading and spans without overhangs4 LIVE load capacities are for those loads that push the panel against its supports The applicable limit states are flexure shear combined shear

and flexure web crippling at end and interior supports and a deflection limit of L180 under strength-level loads5 Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when

utilizing this load chart6 The use of any field seaming equipment or accessories including but not limited to clips fasteners and support plates other than the provided

by the manufacturer may (eave backup rake etc) Damage panels void all warranties and will void all engineering data7 This material is subject to change without notice Please contact Whirlwind for most current data

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 10: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-10 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

GENERAL DESCRIPTION

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II Roof system Therefore other bracing may be required to conform to AISC or AISI Specifications

Coverage Width 24 with Minor Ribs- Prepunched 6 holes

Minimum Slope 14 12

Panel Attachment Low High (Fixed Floating) Utility

Panel Substrate Galvalume Clear Acrylic (standard)

Gauge 22 and 24 GA

Finishes Smooth with Minor Ribs

Coatings Galvalume Clear Acrylic Kynar 500reg

Minimum order or additional set-up fee required

7rdquo

24rdquo Coverage

3rdquo

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 11: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-11SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

STANDARD CLIP HIGH FLOATINGHW-2120

STANDARD CLIP LOW FLOATINGHW-2100

FIXED CLIP LOWHW-200

FIXED CLIP HIGHHW-204

BACK-UP PLATE 24rdquo bull For use at endlaps and at the ridgebull Prepunchedbull 16 Gauge prepainted

SS2BUP (24rdquo)

OUTSIDE CLOSURE 24rdquo For use at ridge or high eave24 Gauge

SS2ED (24rdquo)

CLIP UTILITYbull For application that

do not require the ⅜rdquo insulation clearance provided by the low and high clips

bull For applications over a solid deck

INSIDE CLOSUREMETAL

bull For use at eaveHW-426

EAVE PLATE HIGHbull 10rsquo-0rdquo Lengthbull 14 Gauge Galvanizedbull Factory punched 6rdquo OCbull For use with High clips

EP-501

RAKE SUPPORT LOWbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with low clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

RAKE SUPPORT HIGHbull 20rsquo-0rdquo Lengthbull 14 Gauge paintedbull Factory slotsbull For use with High clips

SS2RSLP (RED-OXIDE)SS2RSLG (GALVANIZED)

3 sup3frasl₈

1⅜rdquo

5rdquo

4⅜rdquo

1⅜rdquo

5rdquo

4⅜rdquo

3rdquo1 frasl16rdquo7

3⅜rdquo

1 frasl16rdquo3rdquo

7

3

1 frasl16rdquo3rdquo

7

UTILITY CLIPHW-208

1⅜rdquo

1⅝rdquo

frac34rdquo

4 ⅜

1 frac122frac12rdquo

3⅜rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 12: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-12 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PRODUCT CHECKLIST

frac14rdquo x 14 x 1frac14rdquo HTZ Teksreg 2frac14rdquo x 14 x 1rdquo Driller Ograverdquo Hex Washer Head with ⅝rdquo OD Washer

bull Clip to purlin with up to 4rdquo insu-lation thickness

bull Eave plate to eave strutbull Inside closure to eave plate or

eave strutbull Mid-Slope Fixed Plate to Purlinbull Light Transmitting panel trim

bull Panel to eave plate eave strut or valley plate

bull Rake trim to roof panelbull Outside closurebull Endlap

17 x 1rdquo Type AB Long Life Ograverdquo Hex Washer Head with Sealing washer

frac14rdquo x 14 x ⅞rdquo Lap Tek Long Life Self DrillerOgraverdquo Hex Washer Head with sealing washer

bull Use in place of Fastenersbull frac14rdquo x 14 x 1frac14rdquo Long Life Tek 2bull frac14rdquo x 14 x ⅞rdquo Lap Tek Long

Life Self Driller

bull Ridge and other flashing to outside closure

bull Gutter to panelbull Gutter to strapbull Trim to trim connections

frac14rdquo x 14 x 1frac14rdquo Shoulder Tek 2 Ograverdquo Hex Washer Head no washer

12 x 1rdquo 2 Pancake Head Driller

bull Rake support to purlin bull Floating eave plate to eave

strut

bull Support plate to purlins at valley and hip conditions

bull Rake angle to purlins

frac14rdquo x 1-frac14rdquo Nail DriveMasonry Anchor

⅛rdquo x sup3fraslrdquo Pop Rivet ⅛rdquo x ⅜rdquo Pop Rivet

bull Special application fastenerbull For use on masonry

bull Gutter strap to snow gutterbull Trim to trim connections

bull Snow gutter to eave platebull Outside closure to back-up angle at

hip condition

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 13: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-13SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPRODUCT CHECKLIST

THERMAL SPACERSSTS- 38SSTS- 58SSTS

LIGHT TRANSMITTING PANEL UL 90Super Seam II -24

TAPE SEAL1 X sup3frasl TAPE SEAL

⅛rdquo x ⅜rdquo Pop Rivet

bull 10rsquo-3rdquo long

Insulated - with Stiffener Plate and 10 fasteners

ReinforcedReinforcedUV Resistant

24rdquo

2rdquo

SPACE BARSB-501

bull Used at the eave plate eave strut outside clo-sures endlaps and trim connections

TAPE SEALER-MINOR RIBPRE-CUT BEVELED1⅜ X 1 x4

bull Used to fill void at minor ribs of the panel at the eave and valleys

3

frac14rdquo x 14 x 1frac14rdquo Driller with ⅛OD Washer ⅜ Hex Washer Head

bull Light transmitting panel to panel and back-up plate

bull Used to hold insulation in place at the rake eave and at any insulation splices

DOUBLE FACED TAPE1frac12 x 180 Rolls

SHAPING TOOLHW-600

bull If a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

frasl

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 14: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-14 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

1 Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the ldquoRake Supportrdquo

2 The walls do not have to be erected before the roof is installed However for the purpose of this manual we have assumed that the wall panels have been installed If the roof is installed before the walls the installer must note the required panel overhang at the eave and use the correct counter flashing per the erection drawings

3 All primary and secondary framing must be erected plumbed and square with bolts tightened according to accepted building practices

4 The substructure (eave to ridge) must be on plane with a tolerance of frac14rdquo in 20rsquo and ⅜rdquo in 40rsquo

5 Super Seam II can be erected on various types of construction However for the purpose of this manual we have assumed that the roof will be installed on a new pre-engineered metal building

6 Super Seam II roof panels are furnished in 24rdquo widths

7 It is critical that the purlins or joists at the ridge and endlaps be exactly located as detailed in this manual and that they are straight from rafter to rafter Any mislocation or bowing of these members can cause the fasteners at the endlaps or outside closures to foul the purlin or the back-up plate to foul the clip as the panels expand and contract

8 Peak purlin spacing - 12rdquo (from the centerline of the building) or 16rdquo for a 9rdquo continuous vent

9 Read recommended erection practices on pages SSII-36 and SSII-37 before proceeding with roof installation

10 Whirlwind recommends the use of a screw gun with a speed range of 0 - 2000 RPM to properly install all fasteners referenced in this manual Tools rated to 4000 RPM should never be used for self drilling fasteners typically supplied with metal building components

11 Field cutting of the panels should be avoided where possible If field cutting is required the panels must be cut with nibblers snips or shears to prevent edge rusting Do not cut the panels with saws abrasive blades grinders or torches

NOTEIt is the responsibility of the erector to install this roof using safe construction practices that are in compliance with OSHA regulations Whirlwind is not responsible for the performance of this roof system if it is not installed in accordance with the instructions shown in this manual Deviations from these instructions and details must be approved in writing by Whirlwind

CAUTIONDiaphragm capabilities and purlin stability are not provided by Whirlwindrsquos Super Seam II roof system Therefore other bracing may be required

CAUTIONThe minimum recommended slope for the roof system is frac14 on 12 A slope of less than frac14 on 12 could cause severe ponding and will void material warranties

CAUTIONApplication and design details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs Projects should be engineered to conform to applicable building codes regulations and accepted industry practices

WARNINGLight transmitting panels are not designed or intended to bear the weight of any person walking stepping standing or resting on them WHIRLWIND DISCLAIMS ANY WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED that any person can safely walk step stand or rest on or near these light transmitting panels or that they comply with any OSHA regulation

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 15: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-15SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIPREPARATORY REQUIREMENTS

UNLOADING

Upon receiving material check ship-ment against shipping list for shortages and damages The manufacturer will not be responsible for shortage or dam-age unless noted on the shipping list

Each bundle should be lifted at its center of gravity Where possible bun-dles should remain banded until final placement on roof If bundles must be opened they should be retied before lifting

When lifting bundles with a crane a spreader bar and nylon straps should be used NEVER USE WIRE ROPE SLINGS OR CHAINS THEY WILL DAMAGE THE PANELS

When lifting bundles with a forklift forks must be a minimum of five feet apart Do not transport open bundles Drive slowly when crossing rough ter-rain to prevent panel buckling

CAUTION

Improper unloading and handling of bundles and crates may cause bodi-ly injury or material damage The manufacturer is not responsible for bodily injuries or material damages during unloading and storage

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAYX

X

5rsquo Minimum

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 16: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-16 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

PREPARATORY REQUIREMENTS

HANDLINGPANEL STORAGEStanding on one side of the panel lift it by the seam If the panel is over 10rsquo long lift it with two or more people on one side of the panel to prevent buck-lingDo not pick panels up by the ends

Store bundle sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to pre-vent rising water from entering bundle Slightly elevate one end of bundle Pre-vent rain from entering bundle by cov-ering with tarpaulin making provision for air circulation between draped edg-es of tarpaulin and the ground PRO-LONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED If conditions do not permit immediate erection extra care should be taken to protect sheets from staining or water marks

Check to see that moisture has not formed inside the bundles during ship-ment If moisture is present panels should be uncrated and wiped dry then restacked and loosely covered so that air can circulate between the panels

BAND ONLYThis method is used on all orders un-less otherwise specified by customer The panels are banded together caus-ing them to curl up This enhances the strength of the bundles Panels bun-dled in this manner may be handled by a forklift in lengths to 30rsquo The forklift should have at least 5rsquo between forks Lengths in excess of 30rsquo must be lift-ed utilizing a spreader bar Special care must be given during handling to avoid damage to the locking edges of the panels

NOTEProtective gloves should always be used while handling panels OSHA safety regulations must be followed at all times

WRONG WAY

10rsquo TO 12rsquo10rsquo TO 12rsquo

5rsquo

RIGHT WAY

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 17: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-17SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Attach the rake support on top of the rake angle with the proper self-drilling fasteners on 2rsquo-0rdquo centers with a fas-tener in the first and last prepunched slot The vertical leg is to be installed square with the eave Center fasten-ers in slots

FASTENER REQUIREMENTSFIXED SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1 SDS w WasherJoist- Fastener

12-24 x 1frac14rdquo Tek 45FLOATING SYSTEMPurlins- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 Joist- Fastener

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2

IT IS IMPORTANT THAT THE RAKE SUPPORT IS INSTALLED STRAIGHT AND SQUARE WITH THE EAVE AS IT CONTROLS THE ALIGNMENT OF THE ROOF SYSTEM

Install 6rdquo pieces of double faced tape on 3rsquo-0rdquo centers to the top of the hor-izontal leg of the rake support This will help hold the insulation in place at the rake

CAUTION(For Floating Systems Only)It is important that shoulder fas-teners are installed through the CENTER of the slotted holes of the rake support to allow for expansion and contraction

STEP 1 RAKE SUPPORT

CAUTIONALL PRIMARY AND SECONDARY FRAMING SHOULD BE ERECTED PLUMBED AND BOLTS TIGHTENED PRIOR TO SHEETING

Steel line

Purlin

Rake Support

12 x 1 Pancake Head Driller

Rake Angle

Double Faced Tape

frac14 - 14 x 1frac14 SDS wwasher

frac14 - 14 x 1frac14 Shoulder Tek 2

Wall Panelfrac14 - 14 x 1frac14 Shoulder Tek 2

Fixed System Only

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 18: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-18 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Eave Strut

OffsetCounterflash

Eave Strut

Counterflash

Wall Panel

Double Faced Tape

Double Faced Tape

10 x 1rdquo Pancake Head Driller

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer 10 x 1rdquo Pancake Head Driller

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

STEP 2 LOW SYSTEM EAVE

For applications in which the wall panels have already been erected install standard counterflash to the eave strut with Fastener 10 x1 Pancake Head Driller Trim must be pulled tight to wall panels before fastening to eave strut For applications in which the wall panels have not been erected use offset counterflash Use two fasteners per 10rsquo piece

For low systems lay 1rdquo x sup3fraslrdquo tape sealer on top of the counterflash

Install double faced tape along the length the top leg of the counterflash Double faced tape must be upslope from 1 x sup3fraslrdquo tape sealer

Lap counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 19: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-19SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP2A LOW SYSTEM EAVE METALINSIDE CLOSURE

Using Fastener frac14rdquo - 14 x 1ldquo SDS wwasher attach the first inside closure to the eave strut locating the face of the inside closure with the steel line NOTE THAT THE FIRST INSIDE CLO-SURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PAR-TIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14rdquo - 14 x 1ldquo SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjustment that may be required Place 1rdquo x sup3fraslrdquo tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation To maintain panel module metal inside closures must be installed on 24rdquo centers Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insu-lation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insula-tion (upslope)

1 x sup3frasl32rdquoTape Sealer

Wall Panel

Counterflash

Metal InsideClosure

Double Faced Tape

10 x 1rdquo Pancake Head Driller

(2) frac14rdquo - 14 x 1rdquo SDS wwasher

Eave Strut

24 OnCenter

Counter Flash

Double Faced Tape

1 x sup3frasl32rdquoTape Sealer

Cut Fiberglassfrom vapor barrierand fold vapor barrier over

CAUTIONThe fiberglass insulation must not interfere with the 1rdquo X sup3fraslrdquo tape seal which provides a positive seal at the eave

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 20: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-20 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

Rake Support

Eave Plate

Eave Strut

Eave Strut

DoubleFaced Tape

OffsetCounterflash

High Eave Plate

Eave Strut

⅛rdquo x sup3frasl16rdquo Pop RivetWall Panel

DoubleFaced Tape

Counterflash

High Eave Plate

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquo SDS wwasher

frac14rdquo - 14 x 1ldquoSDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

Counterflash

3 Lap

Tube Caulking

Tube Caulking

3 Lap

2frac12

Counterflash

2frac12

1rdquo x sup3frasl32Tape Sealer

1rdquo x sup3frasl32Tape Sealer

STEP 2B

WALL PANEL INSTALLED BEFORE ROOF

Install the high eave plate flush with the face of the wall panel Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Install counterflash by attaching to wall panel with Fastener ⅛ x sup3frasl Pop Rivet Use three fasteners per 10rsquo piece

Lay 1 x sup3frasl tape sealer across the top of the counter flashing flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

WALL PANEL INSTALLED AFTER ROOF

Install offset counterflash to eave strut with Fastener ⅛ x sup3frasl Pop Rivet Use two fasteners per 10rsquo piece

Install high eave plates flush with the outside of the counterflash Install Fastener frac14 - 14 x 1 SDS wwasher in each prepunched slot (12rdquo on center) of the eave plate The first eave plate will butt against the rake support You may install all of the eave plates at this time

Lay 1 x sup3frasl tape sealer across the top of the eave plates flush with the outside edge Install double faced tape along the length of the bottom leg of the eave plate

Trim Laps

Lap Counterflash 3rdquo Apply two beads of tube caulking between the trim pieces approximately 2frac12rdquo from the end of the bottom piece

WALL PANEL INSTALLED BEFORE ROOF

WALL PANEL INSTALLED AFTER ROOF

OFFSET COUNTERFLASHTRIM ENDLAP DETAIL

STANDARD COUNTERFLASHENDLAP DETAIL

HIGH SYSTEM EAVEIf the top elevation of the eave member is adjusted by 1 this step is not required

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 21: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-21SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Using Fastener frac14 - 14 x 1 SDS wwasher attach the first inside closure to the eave plate locating the face of the inside closure with the downslope edge of the eave plate NOTE THAT THE FIRST INSIDE CLOSURE MUST BE FIELD CUT IN HALF TO FILL THE VOID UNDER THE PARTIAL RIB

Locate additional closures on 24rdquo cen-ters from the first closure to maintain panel module attaching each with Fastener frac14 - 14 x 1 SDS wwasher Install two fasteners per closure The first fastener should be installed through the slotted hole to allow for any adjust-ment that may be required Place 1 x sup3frasl tape sealer on the top and side of each closure to complete the seal at the eave These may be pre-taped before installation Measure from tab to tab located on the metal inside closure

Roll out insulation from eave to peak laying the side of the insulation on top of the rake support The first roll should be 3rsquo wide This will keep insulation sidelaps 1rsquo from panel sidelaps Allow approximately 4rdquo of insulation to hang past the double faced tape (downslope) before sticking the insulation to the double faced tape Cut and remove the fiberglass approximately 4rdquo and fold the vapor barrier back over the insulation (upslope)

STEP 2C

Double Faced Tape

DoubleFaced Tape

Eave Strut

High Eave Plate

High Eave Plate

Counterflash

Wall Panel

Counterflash

Metal InsideClosure

24rdquo OnCenter

1 x sup3frasl32rdquoTape Sealer

Counterflash

(2)frac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x 1rdquo SDS wwasherat 12rdquo OC

1 x sup3frasl32rdquoTape Sealer

1rdquo x sup3frasl32Tape Sealer

CAUTIONThe fiberglass insulation must not interfere with the 1 x sup3frasl tape sealer which provides a positive seal at the eave

HIGH SYSTEM EAVEMETALINSIDE CLOSURE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 22: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-22 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 3

Position the thermal spacer on top of the insulation over each purlin and against the rake support prior to installing the roof panel

Using spray adhesive adhere the ther-mal spacer to the insulation The ther-mal spacer increases the insulation capacity along the purlins

Double Faced Tape6 Long Pieces at 3-0 On Center

Insulation

Thermal Spacer

Thermal Spacer

Spray Adhesive

Rake Support

24 OnCenter

Double Faced Tape

Counterflashing

Thermal Spacer

THERMAL SPACER(FOR HIGH SYSTEM ONLY)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 23: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-23SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 4

Apply minor rib tape sealer to the underside of the minor ribs of the panel Position so that this tape sealer will cross the 1 x sup3frasl tape sealer on the eave trim (for low systems) or on the high eave plate (for high systems) when the panel is installed

Position the panel so that it overhangs the eave strut by the thickness of the wall covering plus 3rdquo The upper end of the panel must be 7rdquo beyond the web of the purlin

PREPUNCHED PANEL HOLES AT THE EAVE ARE INTENDED TO BE PART OF THE GUTTER OVERHANG AND WILL BE HIDDEN BY THE GUTTER FOR A BUILDING WITH SCULPTURED EAVE TRIM THE PREPUNCHED HOLES WILL BE USED TO ATTACH THE EAVE TRIM TO THE PANEL

Lay the female lip of the panel over the rake support Fasten the panel to the rake support with fastener frac14 - 14 x 1frac14 Long Life SDS 24rdquo oc

Eave Strut

Wall Panel

Metal InsideClosure

Steel Line

Wall CoveringThickness

3

Insulation

Double FacedTape

Counterflash

7

Minor RibTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

1 x sup3frasl32rdquoTape Sealer

1

FIRST PANEL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 24: TECHNICAL ERECTION MANUAL

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-24 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 4Cont

Attach the panel to the eave strut and metal inside closures with Fastener frac14rdquo - 14 x 1rdquo Long Life SDS wwasher Eight fasteners are required at this location

NOTE IT IS ESSENTIAL THAT THE ERECTOR MAINTAIN A 24rdquo MODULE AT THE EAVE WITH THE PROPER INSTALLATION OF THE INSIDE CLOSURES AND BY INSTALLING FASTENERS IN THE PROPER SEQUENCE

all locationsfrac14rdquo - 14 x 1rdquo Long Life SDS wwasher

12 8 7 6 5 4

3

1

FIRST PANEL (Continued)

CAUTIONDo not under any circumstance step on the panel at the seam or at the panel ends until the adjacent side end panels or eave fasteners are fully attached The roof panel may not support the weight of a man at these locations and could affect panel module

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

FASTENER SEQUENCEFIRST RUN - EAVE

NOTEWe recommend the installer pre-drill the holes for fastener 1 and 3 to prevent pushing the flange of the closure out of alignment

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 25: TECHNICAL ERECTION MANUAL

(800) 324 9992 WHIRLWINDSTEELCOM SSII-25SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 5

Slide a back-up plate onto end of panel make sure the teeth on top of the back-up plate are on top of the panel Visually check to see that the holes in the panel align with the holes in the back-up plate

Place tape sealer over the entire width of the panel It must be centered directly over the pre-punched holes following the panel configuration

Cut AndRemove

Cut AndRemove

Cut AndBend

ProtectivePaper

Tape Sealant

RIGHT WAY WRONG WAY

1

BACK-UP PLATE

NOTEAll back-up plates on first panel run will require field modification to avoid fouling rake support

NOTETape Sealer will be 1x sup3frasl depending on condition See steps 7 and 9

CAUTIONForcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most

LOW SYSTEM HIGH SYSTEM

WRONG WAYRIGHT WAY

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-26 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 6

Before installing the first clip clamp the male side of the panel to the side of the back-up plate with a pair of vise grips This will help maintain panel module at the endlaps

Install a clip on the male leg of the panel at the endlap This should be the first clip installed as it controls the 24rdquo module for the remainder of the panel Remove vise grips and install clips on all remaining purlins

FASTENER REQUIREMENTS

FLOATING SYSTEM

Purlins - Fastener

frac14rdquo - 14 x 1rdquo SDS wwasherJoist - Fastener

frac14 - 14 x 1 Tek 5 wwasher(Two fasteners per clip)

24

bull Position the clip over the male leg of the panelas shown and rotate clip downward

bull With the uppper clip firmly seated position the base firmly against the purlin flange

bull When properly positioned the vertical legs of the upper and lower sections of the clip will be 90deg to thepurlin flange pointed upward as shown

frac14rdquo - 14 x 1rdquo SDS wwasher

1

CLIP INSTALLATION

CAUTION The panel clip has factory applied mastic in the upper lip This mastic is compressed when the clip is rotated in place If for some reason a clip must be removed a new clip must be used

IMPORTANTAs each clip is installed maintain a 24rdquo panel module

NOTEThe floating clip is designed so it can only be properly seated when the upper portion of the clip (the tab) is centered on the base

(800) 324 9992 WHIRLWINDSTEELCOM SSII-27SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 7

Position female lip of upper panel over rake support while holding male side of panel up away from the tape sealer Using an awl align the hole nearest the female side of the top panel with the corresponding hole in the lower panel and the back-up plate

Once this is accomplished rotate the male side of the upper panel down to rest on the vise grips

Make sure the panel notches are aligned

Remove awl and insert in the mid-dle hole nearest the male leg Install Fastener frac14 x 14 x 1frac14 Long Life SDS in the hole by the female leg

12

ENDLAP - PANEL

NOTEStep 7 applies only where more than one panel is used in a single slope

CAUTIONThe roof should be swept clean of any drill shavings at the end of each day to prevent rust

Down Slope

2 Required

Panel Clip

4rdquo 3rdquo

3rdquo

frac14rdquo - 14 x 1rdquo SDS wwasher

1 x sup3frasl32rdquoTape Sealer

3rdquo

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-28 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCE

All holes in the upper and lower pan-els and the back-up plate should now be aligned Make sure that the panel notches are aligned

Install Fastener frac14-14 x 1-frac14 Long Life SDS in sequence 2 and 3 Remove vise grips and install remaining fasten-ers in sequence 4 5 6 7 8

Apply 1 x sup3frasl tape sealer over the notched portion of these male legs

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached

STEP 8

12

NOTEStep 8 applies only where more than one panel is used in a single slope

STANDARD ENDLAP

FASTENER SEQUENCE FIRST RUN - ENDLAP

all locationsfrac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo

1 x sup3frasl32rdquoTape Sealer

71 3 2

4

5 68

(800) 324 9992 WHIRLWINDSTEELCOM SSII-29SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

At the ridge install a back-up plate as in Step 5 The back-up plate is neces-sary to maintain panel module

Install 1 x sup3frasl tape sealer over prepunched holes Be sure to place the tape sealer over the male leg DO NOT REMOVE THE PROTECTIVE PAPER AT THIS TIME EXCEPT AT THE MALE LEG

Install clips on ridge panel as in Step 6

STEP 9

ProtectivePaper

1 x sup3frasl32rdquoTape Sealer

3 21

RIDGE PANEL

CAUTION Placing the tape sealer over the male leg of the panel is important Without it water could be driven behind the outside closure by a strong wind

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-30 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 10

Apply tape sealer to the male leg of the first panel run directly over the inside clo-sure This will prevent water infiltration through the end of the seam Install the next run of insulation and another inside closure using Fastener frac14-14 x 1 SDS wwasher The second run of roof is now ready to install

Position the panel with the female lip resting on top of the male leg Align panel flush with adjacent panel ONCE THE PANELS ARE SNAPPED TOGETHER NO FURTHER ALIGNMENTS CAN BE MADE Press down on the seam snapping the two panels together It is important to begin at one end of the panel and work to the other applying pressure contin-uously all the way along the seam to avoid a bubble in the seam Make cer-tain the seams are fully locked together particularly at the clips where greater resistance will be encountered

Install fastener frac14-14 x 1-frac14 Long Life SDS eave in the proper sequence Eight fasteners are required at this location

12 8 7 6 5 4

3

Metal InsideClosure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

43 2

1

SUBSEQUENT RUNS EAVE

CAUTIONNever use a hammer to force the panels to snap together This will cause severe damage to the panel and will nullify any warranty

CAUTIONIf a problem is encountered in fully snapping the seams together such as an incorrectly installed clip damaged panel lip or a bubble caused by faulty assembly the shaping tool should enable the seam to be locked with minimal effort

FASTENER SEQUENCE SUBSEQUENT RUNS - EAVE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-31SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install back-up plate and tape sealer as in Step 5 However on this and all subsequent runs care must be taken to engage the tab on the side of the back-up plate into the slot of the adja-cent back-up plate This procedure will assist in maintaining a 24rdquo panel module

Install clips as described in Step 6

Install upper panel as described in Steps 7 amp 8

Repeat the endlap procedures as required for each panel until the ridge is reached

STEP 11Complete Engagementof Back-Up Plates

frac14rdquo - 14 x 1frac14rdquo Long Life SDSall locations

71 3 2

4

5 68

54

32

1

SUBSEQUENT RUNS ENDLAP

FASTENER SEQUENCE SUBSEQUENT RUNS - ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-32 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 12

Install back-up plate and panel clips Go to the previously installed ridge panel and peel protective paper from tape sealer Apply tape sealer to the ridge panel just installed Be sure to seal to the mastic on the previous panel

Install the outside closure in previous ridge panel Rotate outside closure into position contacting the female side of the panel first Using an awl align the first hole on the female side of the outside closure with the corresponding hole in the panel and back-up plate Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in the hole

Push the other end of the outside clo-sure into position and align the holes with the awl Remove the awl and install Fastener frac14-14 x 1-frac14 Long Life SDS in all remaining holes except for the hole at the panel seam Do not install the panel seam fastener at this time

Check panel alignment at this time (See page SSII-35)

Continue installing the roof until all but the last panel run has been installed

Panel module should be checked every third or fourth run

ProtectivePaper

frac14rdquo - 14 x 1frac14rdquo Long Life SDSAll Locations

1rdquo x sup3frasl32rdquo Tape Sealer

1rdquo x sup3frasl32rdquo Tape Sealer

SUBSEQUENT RUNS RIDGE OUTSIDE CLOSURE

NoteAlways stay one panel run behind with the outside closures otherwise the next panel cannot be installed

43

126

5

(800) 324 9992 WHIRLWINDSTEELCOM SSII-33SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

STEP 13

This roof system is designed to finish in the high on even footage buildings by using 24rdquo panels on the last run

After laying the last insulation run install the rake support over the insu-lation along the steel line Lay the last panel run Fasten the male leg tempo-rarily to the rake support with frac14-14 x 1-frac14 Long Life SDS or with C Clamps

The rake support angle may be from 0rdquo to 4rdquo away from the steel line to cor-rect an out of square condition

Fold BackVinyl

Rake Support

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

Fold BackVinyl

Rake Support

Rake Angle

Steel Line0rdquo-4rdquofrac14rdquo - 14 x 1frac14rdquo Long Life SDS

24rdquo OC

56

43

21

LAST PANEL RUN

CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-34 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

ERECTION SEQUENCESTEP 13A

The roof is designed to finish in the high on even footage buildings Odd length buildings and variations in erection practices may dictate that an alternate detail be used

When terminating in an odd dimen-sion field cut and bend a 3rdquo vertical leg on the panel

After laying the last insulation run install the field formed panel Fasten the formed leg of the panel to the rake support with fasteners frac14 - 14 x 1-frac14 Long Life SDS 24rdquoOC

Fold BackVinyl

Rake Support

Field FormPanel to fit Final

Dimension

Full Panel 6rdquo to 18rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS24rdquo OC

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS

10 x 1rdquo Pancake Head Driller

56

43

21

PARTIAL PANEL (6rdquo TO 18rdquo SPACE PANEL MUST BE FIELD FORMED) CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust

LAST PANEL RUN (OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-35SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIERECTION SEQUENCE

Install Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo in the remaining hole at the panel seam of all outside clo-sures The fastener must go through the panel seam and the corresponding hole of the adjacent outside closure

Use Tube Caulking to fill any voids around panel seam on upslope side of outside closure Apply 1 x sup3frasl tape sealer to the top of the outside clo-sure

The final outside closure on the last panel may require field modification A tab should be formed by the web of the outside closure for attachment to the upturned leg of the roof panel (field formed) This tab should be attached to the panel and angle with Fastener frac14 - 14 x 1-frac14 Long Life SD S 24rdquo (2 required)

Install the ridge flashing starting and ending 2frac12rdquo outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14 -14 x ⅞ Lap Tek Long Life SDS Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

STEP 14

Tube Caulkas Required

Field cut anb bend

Rake support

Field formed tabUpturned Panel Leg

Back-up plate(Field Modified)

Outside Closure

Outside Closure

1frac12rdquo 1frac12rdquo

2frac12rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS (2 Reqrsquod)

1 x sup3frasl32rdquoTape Sealer

RIDGE - OUTSIDE CLOSUREFLASHING

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-36 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Occasionally a purlin may be encountered that is lower (out-of-plane) than those adja-cent to it When a clip is attached to this purlin it will go down further than those adjacent to it distorting the seam This can cause the next panel sidelap to be dif-ficult to snap together in this area To com-pensate for this lower purlin a steel shim may be placed under the clip to bring it up to the proper height (in plane) This shim should be no thicker than frac14rdquo If frac14rdquo is not enough then structural modification will be necessary

Avoid ldquostair-steppingrdquo of the panels at the eave This will cause problems engaging back-up plates at the endlap and ridge

Any ldquostripped outrdquo fasteners at the endlaps or outside closures should be immediately replaced with 17 x 1 Type AB fastener Place a 1rdquo long piece of use 1 x sup3frasl tape sealer over the ldquostripped outrdquo hole before installing 17 x 1 Type AB fastener This will allow the fastener threads to be coated with tape sealer and provide a good seal

NEVER ALLOW PANELS TO COME INTO CONTACT WITH LEAD COPPER GRAPHITE GASOLINE OR OTHER HARSH CHEMICALS AS THIS WILL VOID THE GALVALUMEreg WARRANTYCHECK ROOF FOR PANEL ALIGNMENTCheck the roof every three or four runs for panel alignment as it is being erected This can be accomplished by two different means1 Measure from the rake support to the

seam of the last completed panel run Take measurements at the ridge eave and all endlaps

2 Attach a stringline to the eave plate and ridge purlin running parallel to the rake support The stringline should stay ahead of the work and can be moved across the roof as construction pro-gresses Measure from the stringline back to the last completed panel run Take measurements at the ridge eave and all endlaps

X

Steel Shim

x

x

Eave Strut

Peak Purlin

FIRST PANEL LAST COMPLETED PANEL RUN

RECOMMENDED ERECTION PRACTICES

CORRECTING OUT - OF - PLANE SUBSTRUCTURE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-37SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

To stretch panel coverage install an floating clip at the panel endlap or ridge with the base angled away from the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move outward stretching the panel coverage Install the remain-der of the clips as usual

To shrink panel coverage install a clip at the panel endlap or ridge with the base angled toward the panel As the fastener is installed through the base of the clip and into the purlin the clip base will rotate down to the purlin causing the top of the clip to move inward shrinking panel cover-age Install the remainder of the clips as usual

FIXED AND FLOATING CLIPS

To stretch panel coverage bend the sides of the back-up plate out and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

To shrink panel coverage bend the sides of the back-up plate in and install at endlap or ridge Do not bend either side more than frac14rdquo Install clips as usual

Floating Clip

StretchingPanel Coverage

ShrinkingPanel Coverage

Floating Clip

frac14rdquo MAX frac14rdquo MAX

frac14rdquo MAX frac14rdquo MAX

RECOMMENDED ERECTION PRACTICES (Continued)

ADJUSTING PANEL WIDTH FLOATING CLIP ONLY

NOTEDo not adjust panel width more than frac12rdquo on any panel area

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-38 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Turn ventilator over and place gently on its top Note that the end cap is pre-formed for a 112 roof pitch The five bench mark dots represent 212 312 412 512 and 612 roof pitches Draw a line between indicated corners and the appropriate dot for the roof pitch Cut and remove that portion of the end cap On 512 and 612 roof pitches see vent manufacturerrsquos special instruc-tions for the installation of the vent skirt The end cap is now ready to receive the end skirt

Position end skirt onto end cap Be sure the down-turned angle of the end skirt is inside of and up against the end cap Attach end skirt to ventilator end cap with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS in four places

PreformedFor A 112 Pitch

212312412

End CapScribe Line

Side Skirt

End Skirt

End Cap

DamperControl Arm

End Cap

512612

frac14rdquo - 14 x ⅞rdquo Long Life SDS

RIDGE VENTILATORINSTALLATION

NOTEWhirlwind does not recommend the use of a ridge ventilator on standing seam roof systems Sidewall or endwall exhaust fans or other ventilating methods should be considered These details are for your convenience only Only a 9rdquo ridge ventilator can be used with this SSR system Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

(800) 324 9992 WHIRLWINDSTEELCOM SSII-39SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Apply 1 x sup3frasl tape sealer to top of out-side closures Install ventilator making sure to center in opening Attach venti-lator to outside closures with Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS on 6rdquo centers Use caulking to seal between the outside of the ventilator and the end skirt

Install the ridge flashing as in Step 14 except for those pieces on either side of ventilator These will lay on top of and seal to the ventilator end skirt with a ridge end cap Use 1 x sup3frasl tape sealer to seal the ridge end cap to the ridge flashing and the end skirt Use Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS to install the end cap Six fasteners are required to tie the end cap to the ventilator end skirt Eight fasteners are required to tie the end cap to the ridge flashing

For continuous ventilators install end skirts on both ends of the first venti-lator and one end of all following ven-tilators Attach ventilator to outside closures as outlined above Install an additional Fastener frac14 - 14 x ⅞ Lap Tek Long Life SDS through the corner of the side skirt and into the end skirt

Do not connect more than 3 vents to the same linkage

End SkirtEnd Skirt

TubeCaulking

VentilatorEnd Cap

Tube Caulking

Ridge Flashing

Ridge End Cap

TubeCaulking

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

End Skirt

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek

RIDGE VENTILATORINSTALLATION (Continued)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-40 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

91-4 7

Back-upPlate

OutsideClosure

Insulation

Clip

Ridge Ventilator

frac14rdquo - 14 x 1frac14rdquo Long Life SDSfrac14rdquo - 14 x 1rdquo SDS wwasher

frac14rdquo - 14 x ⅞rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

NOTES1 Only 9rdquo ridge ventilators can be used with this SSR system2 Do not use ridge ventilators on any roof over 200rsquo in width or with a slope less than 112 or greater than 612

RIDGE VENTILATOR

(800) 324 9992 WHIRLWINDSTEELCOM SSII-41SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Tube Caulking at Closure End Panel Ribamp Lapping Closure Tabs to Seal all Voidsfrac14 - 14 x 1frac14 Long LifeSDS wwasher3 per Panel

Perforated Vent Drip

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life at 6rdquo OC

Outside Closure

Ridge Flashing

Backup Plate

Cont Across Panel

NoteReference Typical Trim Lap Sections

frac14 - 14 x 1frac14 Long LifeSDS wwasherat Pre-Punched Holes(6) per 24rdquo Panel

Super Seam IIPanel

Purlin

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life spaced 1frac12rdquo

from Panel Seams winteriorfasteners centered

over Minor Ribs (7rdquo OC Max)No Fastener at Panel Seam)

Low Sliding Clip1 x sup3frasl32rdquo Tape Sealer

frac14rdquo - 14 x 1rdquo SDSwwasher (2) per Clip

⅜rdquo

5rdquo

1 x sup3frasl32rdquo Tape Sealer

2rdquo1rsquo - 0rdquo Max

Tube Caulking

Perforated Vent Drip

Lap(Min)

3rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

at 3rdquo OC (Max)

Super Seam IIPanel

7

Ridge Cap

Vent Material

6rdquo OC

Cobrareg VentMaterial

24rdquo OC

Panel Clip

Purlin

OutsideClosure

Back-up Plate

2rdquo5rdquo

1rsquo-0rdquofrac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

6 per panel

frac14rdquo - 14 x 1ldquo SDS wwasher2 Required

PERFORATED VENT DRIP

VENTED RIDGE

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-42 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

WallPanel

Gutter Strap

Insulation

3rdquoWall Panel Thickness

OffsetCounterflashing

Insulation

Floating HighEave Plate

(HW-7618 or HW-7629)

Panel

Counterflashing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

Floating Low Eave Plate (HW-7617 or 7628)

Double Faced Tape

DoubleFaced Tape

Inside Closure

Inside Closure

Endlap

Low Mid FixedPlate (HW-7632)

Lower Panel

Upper Panel32frac34

⅜rdquo

Inside Closure

1⅜rdquo High Mid FixedPlate (HW-7636)

32frac34rdquo

Lower Panel

Upper Panel

InsideClosure

Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1rdquo SDS wwasher6 OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Endlap

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

⅛rdquo x sup3frasl16rdquo Pop Rivet

frac14rdquo - 14 x ⅞rdquo Lap Tek Long Life SDS

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

LOW SYSTEM HIGH SYSTEM

LOW SYSTEM HIGH SYSTEM

NOTES1 This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip Please refer to page SSII-42 A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge3 The standard floating ridge condition must be used in conjunction with this special eave detail4 The floating eave plate must be used to allow for panel movement at the eave5 Floating clips have a maximum movement of 1rdquo in each direction Thermal calculations must be performed for each project to ensure that

the thermal movement of the roof will not exceed the design of the clips and slot in the floating eave plate

MID SLOPE FIXED CONDITION

(800) 324 9992 WHIRLWINDSTEELCOM SSII-43SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

The manufacturer recommends that only one-piece 080 aluminum curbs be used on itrsquos standing seam roof systems The curb flange is constructed to match the configuration of the panel The side flange extends to the next natural seam in the roof panel and conforms to the seam configuration Cap strips fur-nished by the curb manufacturer secure the curb to the roof panels The roof curb is installed under the roof panels on the upslope end and on top of the roof panels on the downslope end Support framing should be installed before curb installation Back-up plates (for the roof panels at the down slope end of the curb) a floating eave plate (for the upslope end of the curb) long-life fasten-ers and Triple Bead tape sealer must be ordered for each curbThese curbs may be installed as the roof is being installed or after the roof has been installed Since the curb sides are an integral part of the roof seam the curb must align with the roof panel seams If the curb can be shifted up to 12rdquo to either side the curb can be pre-ordered and be installed with the roof panels or installed after the roof is in place If the curb place-ment is critical install the curb support framing at the desired location and roof over it Measure the panel rib locations in reference to the required curb opening and order the roof curb for each location The curbs can then be installed in each location ensuring an exact fit

Upper Panels At Curb

Lower Panels At Curb

DOWNSLOPE

15 MIN

7

12 MIN

1frac12

1 frac12rdquo

3

7

ROOF CURB INSTALLATION

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

ROOF CURB CROSS SECTION

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-44 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Floating Eave PlateLow System HW-7617High System HW-7655

Triple Bead

Male Leg

Downslope

Lower Panels at Curb

Purlin Framing MemberOr Secondary CurbSupport Framing

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek 2 SDS at 12rdquo OC

1 frac12

INSTALLING CURB WITH ROOFInstall curb support framing at curb location Install full length roof panels up to curb location Install lower panels at downslope end of curb If the lower panels are field cut to length you must (1) cut the downslope end leaving a factory cut at the curb end or (2) if the curb end of the panel is field cut notch the male leg as it is done in the factory Place Triple Bead tape sealer across the full width of each panel as it is installed To determine how far down on the panel to place the tape sealer temporarily lay the curb in place and mark the down slope edge of the curb on the first panel This will give you a reference point as to how far down slope to place the tape sealer It is critical that the tape sealer be installed across each panel individually so that the tape sealer can be placed over the male leg This will provide a seal in the panel seam when the next panel is installed Install back-up plates onto each of the lower panels

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-45SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Downslope

Floating Curb

Purlin

Triple Bead

Back-up Plate

1-0 Min Typ

Triple Bead

Lower Panelsat Curb

Male LegOf Panel

TubeCaulking

InsideCap Cell

Triple Bead

Direction Of Installation

Downslope

Minor Rib TapeSealer

Upper Panelsat Curb

Lower Panelsat Curb

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

Install the roof curb on top of the lower roof panels and the curb sup-port framing Do not attach the curb to the support framing as this may prevent the curb from floating with the roof Fasten the down slope end of the roof curb to the lower roof panels and back-up plates with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead

Install Triple Bead across the width of the upslope end of the roof curb Use the down slope end of the inside cap cell which is welded to the roof curb as a guide for placement of the tape sealer

Apply minor rib tape sealer to the underside of the minor ribs on the down slope end of the upper panels Install the upper panels with Fastener frac14 - 14 x 1-frac14 Long Life SDS as at a standard endlap This will require six fasteners in the pan of the panel and one in each trapezoid for a total of eight fasteners per panel Fasteners must go through the Triple Bead tape sealer The down slope edge of these panels should be flush with the down slope edge of the inside cap cell Apply tube caulking to the male leg of all panels directly over the inside cap cell This will prevent water infiltration through the end of the panel seam

INSTALLING CURB WITH ROOF(Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-46 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Rib To Rib Dimension

Center Of Opening To Panel Rib

Center Of Opening To Panel Rib

Roof Penetration Opening

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

After all upper panels have been installed install full length panel at side of curb This panel will engage the male leg of the adjacent upper and lower panels The female leg of this full length panel will overlap the leg of the roof curbCap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB WITH AFTER ROOF INSTALLATIONWhen curbs must be installed in an exact location the curb support framing can be installed before beginning the roof When a curb is to be added after the roof is installed the curb framing must be installed from below the roof after the roof panels have been cut for installation of the curbAfter roof is installed identify the exact location for the curb Measure from the center of the required opening to the near-est panel rib in each direction Also deter-mine how many panels will be affected by the curb (minimum clearance between vertical wall of curb opening and panel rib is 6rdquo) and measure from center of rib of first panel affected to center of rib of last panel affected (if 24rdquo panel module was not held during roof installation this dimension will be critical) This informa-tion will be required to fabricate the curb so that it will fit the location exactly

INSTALLING CURB WITH ROOF(Continued)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-47SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

Once curb is ready to be installed lay curb on roof and align opening in the curb with the exact location the opening is required in the roof At the up slope end of the roof curb the roof panels will be cut on a line even with the beginning of the notch at the ver-tical leg on each side of the roof curb Secondly trace a line along the down slope edge of the roof curb The roof panels will be cut on a line 4rdquo up slope from this lineCut roof panels from rib of first panel affected by curb to rib of last panel affected along the top and bottom cut lines previously markedAt the down slope end of the roof opening install back-up plates onto the ends of the cut roof panels and Triple Bead across the full width of these roof panels The down slope edge of the tape sealer should be on the line previously traced along the down- slope edge of the roof curb The up slope edge of the tape sealer will be approximately 1Zxrdquo from the end of the cut panel

Apply Triple Bead across the full width of the up slope end of the roof curb The down slope edge of the tape sealer will align with the down slope edge of the inside cap cells welded to the roof curbInstall the roof curb under the roof panels at the up slope end and on top of the panels at the down slope end This will require that you lift the roof panels up slightly at the up slope end to allow the upper flange of the roof curb to slide under the panels Spray some soapy water on the tape sealer to prevent it from sticking to the roof panels until you have the curb com-pletely in place

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

RequiredOpening In Roof

Mark Line at Curb Edge

(For 1 x sup3frasl32rdquo TapeSealer Placement)

Mark Line at Notch In Curb

DOWNSLOPE

Upper Panelsat Curb

Lower Panelsat Curb

Panel Cut Line

4

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-48 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Upper Panels at Curb

DOWNSLOPE

Lower Panels at Curb

Tube CaulkingCap Strip

Cap Strip

Triple Bead

frac14rdquo - 14 x ⅞rdquo Long Life Lap Tek6rdquo OC

Cap strips will be installed full length along both sides of the curb to seal the curb to the roof panels Turn the cap strips upside down and install Triple Bead to both sides and along the full length of the cap strip Lower edge of tape sealer should be flush with the lower edge of the cap strip Apply a generous bead of urethane sealant at both ends of the seam portion of the cap strip Install each cap strip over the curbroof panel sidelap with the lower end of the cap strip even with the lower end of the curb Force the cap strip down tightly to the curbroof panel sidelap and fasten both sides with Fastener frac14 - 14 ⅞ Lap Tek Long Life at 6rdquo on center

INSTALLING CURB AFTER ROOF INSTALLATION (Continued)

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

(800) 324 9992 WHIRLWINDSTEELCOM SSII-49SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IISPECIAL ERECTION TECHNIQUES

3

7

1

5

8Downslope

15 min

7

12 min

1 frac12

1 frac12

3

7

8

7 4

3

25

6

5

1012

11

9

12

26

1 Super Seam II Panel

2 Tube Caulk

3 Outside Cap Cell

4 Back-up Plate

5 Fastener frac14 - 14 X 1-frac14 Long Life SDS

6 Triple Bead

7 Roof Curb

8 Water Diverter

9 Inside Cap Cell

10 Floating Eave Plate

11 frac14rdquo - 14rdquo x 1-frac14rdquo Shoulder Tek 2

12 Purlin Framing Member or sec-ondary Curb Support framing

ROOF CURB CROSS SECTION

CAUTIONThe above curb type and installation instructions must be used for curbs to be included in a weathertightness warranty

ATTENTIONAll curbs must be installed over support framing supplied by the metal building manufacturer or the curb supplier Support framing must be properly located to provide ldquoendlaprdquo conditions at the upslope and downslope ends of the curb Refer to Roof Curb Cross Section for critical dimensions

WARNINGIt is the userrsquos responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State Federal and OSHA regulations and laws including but not limited to guarding roof openings with plywood fixed standard railings or other acceptable safety controls that prevent fall-through

ROOF CURB ISOMETRIC

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-50 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

SPECIAL ERECTION TECHNIQUES

Purlin

Roof PanelClip

S-5trade UD Wind Clamp

S-5trade UD Wind Clamp(Hw-569)

Purlin

Roof PanelClip

Super Seam IIRoof Panel

Purlin

Roof PanelClip

S-5trade UD Wind Clamp(Clamp Must be Torqued To 140 In Lbs)

Super Seam IIRoof Panel

Super Seam IIRoof Panel

NOTES1 Torque set screw to 140 in-Lbs2 Application zone and feasibility of wind clamps must be determined by a Registered Professional Engineer

S-5 SUPER SEAM PLUS WINDCLAMPINSTALLATION LOCATION

SECTION A-A SECTION B-B

(800) 324 9992 WHIRLWINDSTEELCOM SSII-51SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

GutterStrap

(48rdquo OC)

Counterflash

Metal Inside Closure

High EavePlate

Double Stick Tape

⅛rdquo x sup3frasl16rdquo Pop Rivet

Insulation

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

Wall CoveringThickness

3rdquo

Insulation

Back-upPlate

ClipGutter

Gutter Strap(24rdquo OC)

Counterflash

MetalInside

Closure

3rdquo4rdquo

Gutter Strap

TapeSeal

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x 1frac14rdquoLong Life SDS

8 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDSPanel to Eave8 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

⅛rdquo x sup3frasl16rdquo Pop Rivet

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

frac14rdquo - 14 x 1rdquo SDS wwasher

2 per Inside Closure

NOTE1 The above gutter should not be used in areas that experience snow loads of 10 PSF or higher See page SSII-57 for the gutter detail for

these areasSEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS EAVE TO ENDLAP

HIGH EAVE

GUTTER STRAP END VIEW

ENDLAP END VIEW

LOW EAVE ENDLAP

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-52 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

OutsideClosure

Ridge Flash 1frac12 7 7 7

24

Back-upPlate

12

Clip

Insulation

OutsideClosure

9 Per Panel

Ridge Flashing

57

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

OutsideClosure

1frac14 Plus EndwallThickness

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 6rdquo OC 4 per panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Clip

1 x sup3frasl32rdquoTape Sealer

1frac12 1frac12 frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

frac12 frac34

frac12frac12 1 1 1

frac34 frac12frac34

frac12frac121 1 1

frac34

Install the ridge flashing starting and ending 1frac14rdquo plus endwall thickness outside the steel line Fasten the ridge flashing to the outside closures with Fastener frac14rdquo - 14 x 1rdquo SDS wwasher 2 per Inside Closure Install a fastener 1frac12rdquo from panel seam on both sides of panel Install additional fasteners directly above minor ribs of panel Four fasteners are required at each panel Leave 6rdquo unfastened on each end to allow for the rake trim to be installed later DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM

CAUTIONSuper Seam II systems must utilize a Floating Peak Box

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RIDGE

(800) 324 9992 WHIRLWINDSTEELCOM SSII-53SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS

(24 OC)

Insulation

RakeSupport

RakeAngle

ClosureWall Panel

Rake Trim

Roof Purlin

Field FormedPanel Edge

Insulation

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

Roof Purlin

Termination Trim

Insulation

Clip

RakeSupport

RakeAngle

Closure

Wall Panel

Rake Trim

10 x 1rdquo Pancake Head Driller

10 x 1rdquoPancake Head Driller

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

12rdquo OC

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life (6rdquo OC)

1 x sup3frasl32rdquoTape Sealer

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder TekSDS(24 OC)

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life(12rdquo OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS(24 OC)

10 x 1rdquoPancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Clip

SEE PAGES SSII-12 FOR FASTENER SELECTION

TRIM DETAILS RAKE

BEGINNING RAKE TRIM

TERMINATION RAKE TRIMOFF MODULE

TERMINATION RAKE TRIMOFF MODULE (OPTIONAL)

TERMINATION RAKE TRIMON MODULE

RAKE SLIDE(FOR FLOATING SYSTEMS ONLY)

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-54 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Purlin

ParapetRake Cleat

Rake Angle

Rake SupportAngle

Parapet RakeFlash

2 MinimumSuper Seam IIPanel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Nail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS

(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Tube Caulking

AlternateCounterflash

Tube CaulkingCounterflash

Parapet RakeFlash

Rake SupportAngle

ParapetWall

ParapetRake Cleat

Rake Angle

2 Minimum2 Minimum

Super Seam IIPanel

Tube Caulking

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoNail Drive

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1frac14rdquo Nail Drive

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Purlin

frac14rdquo - 14 x 1frac14rdquoNail Drive 1 x sup3frasl32rdquo

Tape Sealer

frac14rdquo - 14 x 1frac14rdquo Shoulder Tek SDS(24 OC)

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

10 x 1rdquo Pancake Head Driller

TRIM DETAILS RAKE

BEGINNING PARAPET RAKE TERMINATION PARAPET RAKE

TERMINATION PARAPET RAKE(OPTIONAL)

(800) 324 9992 WHIRLWINDSTEELCOM SSII-55SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Tube Caulking

Counter Flash

Back-Up plate

Parapet Flashing

Panel

Clip

Purlin

5rdquo7rdquo

frac14rdquo - 14 x 1frac14rdquo Long Life SDS6 per Panel

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS frac14rdquo - 14 x 1frac14rdquo Nail Drive

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

2 Required

NOTE

1 High side purlin is 12rdquo down slope

TRIM DETAILS RAKEHIGH EAVE PARAPET

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-56 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Counterflash

Eave Trim

Metal InsideClosure

Insulation

Counterflash

SculpturedEave Trim

Closure

Wall Panel

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x 1rdquo SDS wwasher2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

6 per Panel

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life

12rdquo OC

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

Panel to Eave8 per Panel Wall Panel

Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS9 per Panel

frac14rdquo - 14 x 1rdquoSDS wwasher

(2) Required

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life SDS

OutsideClosure

Insulation

High Side Eave Trim

Clip

2 Plus Wall PanelThickness

1 Min

frac14rdquo - 14 x ⅞rdquo Lap TekLong Life 12rdquo OC

EaveStrut

NOTE1 This optional sculptured eave trim is available However under certain conditions it may induce staining of wall panels2 Place the frac14 - 14 x ⅞ Lap Tek through the pre-punched holes in the roof panel

TRIM DETAILS EAVE

HIGH EAVE

LOW EAVE WITH SCULPTURED EAVE TRIM

(800) 324 9992 WHIRLWINDSTEELCOM SSII-57SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Metal Inside Closure

Gutter Strap(3rsquo-0rdquo OC)Panel

InsulationDouble

Face Tape

Eave Strut

Wall Panel

High EavePlate

SnowGutter

SnowGutter

Wall Panel

Eave Strut

DoubleFace Tape

Insulation

Metal Inside ClosureGutter Strap(3rsquo-0rdquo OC)

Panel

frac14rdquo

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x sup3frasl16rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

⅛rdquo x ⅜rdquo Pop Rivet

frac14rdquo - 14 x 1rdquoSDS w washer

12rdquo OC

frac14rdquo - 14 x 1rdquoSDS w washer

2 per Inside Closure

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Inside Closure

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

1 X sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1frac14rdquoLong Life SDS8 per Panel

NOTES1 Attach gutter to eave plate with Fastener ⅛ x ⅜ Pop Rivet (3 fasteners per 10rsquo piece)2 Install gutter straps 3rsquo-0rdquo OC3 Apply 1 x sup3frasl tape sealer to slope leg of gutter4 Use minor rib tape sealer to fill voids in panel at minor ribs as shown on page SSII-235 Install panel with Fastener frac14 - 14 x 1frac14 Long Life SDS at prepunched holes Panel must not overhang into gutter6 Front top edge of gutter must not project above the plane of the panel pan

HIGH SYSTEM

LOW SYSTEM

TRIM DETAILS SNOW GUTTER

TECHNICAL ERECTION MANUAL SUPER SEAM II

SSII-58 SUBJECT TO CHANGE WITHOUT NOTICEEFFECTIVE JANUARY 1 2018 (800) 324 9992 WHIRLWINDSTEELCOM

DESIGN

Clip

Panel

14 Ga PlateHip Support

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Floating RidgeHip Flashing

ldquoZrdquo Closure(Field cut to lengthand Bevel cut to fit Panel)

Purlin

Floating RidgeHip Flash

Purlin

ldquoZrdquo Closure(Field cut to

length and Bevel cut to fit Panel)

2rdquox 2rdquox 16 GaBack-Up Angle

Tube Caulking

Panel

14 Ga PlateHip Support

2rdquoplusmn5rdquo

1 x sup3frasl32rdquoTape Sealer

frac14rdquo - 14 x 1rdquoOD washer

1 x sup3frasl32rdquoTape Sealer

⅛rdquo x ⅜rdquo Pop Rivet4rdquo OC Max

10 x 1rdquo Pancake Head Driller2 per Purlin

⅛rdquo x ⅜rdquo Pop Rivet

10 x 1rdquo Pancake Head Driller2 per Purlin

frac14 x 14 x ⅞ Long Life Lap Tek 6rdquo6rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS HIP

(800) 324 9992 WHIRLWINDSTEELCOM SSII-59SUBJECT TO CHANGE WITHOUT NOTICE EFFECTIVE JANUARY 1 2018

TECHNICAL ERECTION MANUAL SUPER SEAM IIDESIGN

Direction

of Installation

Tube Caulking

Male Legof Panel

InsideMetal Closure

Triple BeadTape Sealer

Support Plate(14 Ga)

Purlin

Inside Closure

1frac12rdquo

5rdquo

Valley Trim

Panel Triple BeadTape Sealer

10 x 1rdquo Pancake Head Driller

frac14rdquo - 14 x 1rdquoSDS wwasher

2 per Closure

Panel Rib

8 Long piece ofTriple-Bead Tape sealer underInside closure

Beveled Edge ofRoof Panel

Inside Metal ClosureInside Closure

Field Cut PanelTo Valley Trim

Valley Trim

frac14rdquo - 14 x 1frac14rdquo Long Life SDS

3rdquo OC

Triple BeadTape Sealer

Triple BeadTape Sealer

frac14rdquo - 14 x 1frac14rdquo Long Life SDS3rdquo OC

CAUTIONAll trapezoidal panels are extremely difficult to install at hips and valleys in a weathertight manner The use of these details should only be attempted by installation crews that are highly experienced In order to assure weathertightness Whirlwind recommends one of itrsquos vertical leg standing seam systems for use on roofs that require hips and valleys

TRIM DETAILS VALLEY

WHIRLWINDSTEELCOM (800) 324 9992

Page 26: TECHNICAL ERECTION MANUAL
Page 27: TECHNICAL ERECTION MANUAL
Page 28: TECHNICAL ERECTION MANUAL
Page 29: TECHNICAL ERECTION MANUAL
Page 30: TECHNICAL ERECTION MANUAL
Page 31: TECHNICAL ERECTION MANUAL
Page 32: TECHNICAL ERECTION MANUAL
Page 33: TECHNICAL ERECTION MANUAL
Page 34: TECHNICAL ERECTION MANUAL
Page 35: TECHNICAL ERECTION MANUAL
Page 36: TECHNICAL ERECTION MANUAL
Page 37: TECHNICAL ERECTION MANUAL
Page 38: TECHNICAL ERECTION MANUAL
Page 39: TECHNICAL ERECTION MANUAL
Page 40: TECHNICAL ERECTION MANUAL
Page 41: TECHNICAL ERECTION MANUAL
Page 42: TECHNICAL ERECTION MANUAL
Page 43: TECHNICAL ERECTION MANUAL
Page 44: TECHNICAL ERECTION MANUAL
Page 45: TECHNICAL ERECTION MANUAL
Page 46: TECHNICAL ERECTION MANUAL
Page 47: TECHNICAL ERECTION MANUAL
Page 48: TECHNICAL ERECTION MANUAL
Page 49: TECHNICAL ERECTION MANUAL
Page 50: TECHNICAL ERECTION MANUAL
Page 51: TECHNICAL ERECTION MANUAL
Page 52: TECHNICAL ERECTION MANUAL
Page 53: TECHNICAL ERECTION MANUAL
Page 54: TECHNICAL ERECTION MANUAL
Page 55: TECHNICAL ERECTION MANUAL
Page 56: TECHNICAL ERECTION MANUAL
Page 57: TECHNICAL ERECTION MANUAL
Page 58: TECHNICAL ERECTION MANUAL
Page 59: TECHNICAL ERECTION MANUAL
Page 60: TECHNICAL ERECTION MANUAL