Technical Datasheets - Oddicini
Transcript of Technical Datasheets - Oddicini
TechnicalDatasheets
MAXPARETEHSPHighSoundProofingPYROMNP
1Features
2WorkingScheme
6TracksAnchorageSystems
3Sections
4Elements
5TracksandCoverings
7StackingSchemes
8TrolleysandTracks
9IdeasforPlanning
MAXPARETEHSPHighSoundProofingPYROMNP
Features
MAXPARETE HSP PYRO MNP - Features - 1
The use of operable partitions in maritime safety is possible with MAXPARETE HSP PYRO MNP. This partition reaches its maximum fire resistant value complying with European standards and represents the ideal solution in order to dynamically close rooms high up to 2.83 meters, assuring a perfect sound proofing.
MAXPARETE HSP PYRO MNP represents an operable partition - pass door system tested according to italian and international standards and resulting:
Blind Partition: B15 as M.E.D. Directive (Marine Equipment Directive) - tested as B30
Where:
B: with reference to "B" Class Bulkhead - Res. A.754(18)15/30: certified reference time (in minutes) within which the bulkhead retains its properties
MAXPARETE HSP PYRO MNP, covered with panels with fire inert core (calcium sulphate), consists of sliding elements with standard width between 600 and 1200 mm; the telescopic element has always variable width between 740 and 1320 mm.
Pass doors may be fitted to any intermediate element (except for the telescopic closure element) of the MAXPARETE HSP PYRO MNP operable partitions without altering the normal functionality.
Vertical profiles (always "visible") are covered with special fire resistant paint.
Technical Characteristics
ThicknessStandard elements are 110 mm thick.
FinishingsMAXPARETE HSP PYRO MNP is available in a wide choice of finishings:
Aluminium natural profiles (always "visible") covered with special fire resistant paint
Track with fire resistant covering (calcium sulphate or material with similar characteristics) and covered with special fire resistant paint (at least in working areas).
Panels surfaces in:- Raw calcium sulphate to be covered by customer with upholstery, cloth, carpet, etc.- Standard colours High Pressure Laminate on calcium sulphate- Standard vinyl coverings on calcium sulphate
Sound ProofingWhen closed the operable partition is perfectly aligned, without fissures and mechanical parts in view. MAXPARETE HSP PYRO MNP allows a sound proofing (Rw index) from 41 to 50 dB according to the types.
The materials used for the supply are tested according to UNI EN ISO 717-1 and UNI EN ISO 10140-2 standards. The test report (if demanded) is available within 30 days maximum prior to the delivery of the
MAXPARETE HSP PYRO MNP - Features - 2
partitions, evidencing the conformity to the soundproofing requests and is attached to the transport documents. More, the customer can assist to the tests with at least a 15 days warning.
Fire ReactionNon-combustible panel core according to EN ISO 1182 rule
Fire ResistanceBlind Partition: B15 as M.E.D. Directive (Marine Equipment Directive)Partition with Door: B15 as M.E.D. Directive (Marine Equipment Directive)
Resistance to ShocksUNE 41956-1 compliant
Weights2
The weight of the partition is 60/100 kg/m . according to the finishing of the surface and the sound proofing level.
Laboratory TestsThe very high performance of MAXPARETE HSP PYRO MNP sound proofing, the fire tests, the quality of the materials and of the productive process are verified and tested by the main European Laboratories.
MAXPARETE HSP PYRO MNP has obtained sound proofing and fire reaction certificates from CSI.
Features
Elements
STANDARD ELEMENTThe standard element represents the typical element used to close the different rooms. Elements are locked in shut position by means of two movableseals which are simultaneously hand or electrically operated by a control inserted in the rabbet; the seals are pushed against the floor and the rail, so that the wall space is hermetically closed. The standard width of the elements is between 600 and 1200 mm.
SELF-BEARING STANDARD PANELOnce the element is put in position and locked, it can lighten his weight the overhanging structure. This way, the load-bearing structures are burdened by the elements weight only during sliding operations (i.e. only one element at a time). It is very important that each element is correctly placed in position perfectly perpendicular and aligned with others before locking. The standard width of the elements is between 600 and 1200 mm. It is not possible to produce self-bearing expander elements and self-bearing elements with pass doors inserted.
EXPANDER ELEMENTThe opening and closing manoeuvres of the partitions are effectuated by means of the expander element, always installed laterally. This one is the first one to be unlocked when you need to open the partitions and stack the elements and the last one to be locked when you need to close them. The expander element is produced in two versions - MONODIRECTIONAL and MULTIDIRECTIONAL - with variable width between 740 and 1320 mm and with stroke between 100 and 170 mm.
MAXPARETE HSP PYRO MNP - Features - 3
Features
Tracks
Tracks are in EN AW 6005/A high resistance aluminium. The manoeuvre of the panels is easy and you can do it without effort. The ball bearing trolleys slide with precision in the aluminium track. The different typologies and the different utilization ways of the tracks are shown here below:
TRACK TYPE 100Suitable for monodirectional stacking scheme - Utilizing 1 trolley type 10 for heights up to 283 cm
TRACK TYPE 800Suitable for multidirectional stacking scheme - Utilizing 2 trolleys type 80 for heights up to 283 cm
Tracks must have fire resistant covering (calcium sulphate or material with similar characteristics) and must be covered with special fire resistant paint (at least in working areas).
SINGLE PASS DOOR ELEMENTPass doors may be fitted to any intermediate element except for the telescopic closure element. The elements where we can insert a pass door have a fixed width of 1220 mm and allow a pass door wing of 900 with an height of 2120 mm. The thickness of the pass doors is 106 mm. By request we can supply elements with special measures.
MAXPARETE HSP PYRO MNP - Sheet 2.1 - Rev.01
WorkingScheme
Sections
Standard Element - Vertical Section
MAXPARETE HSP PYRO MNP - Sheet 3.1 - Rev. 02
30
30
Sections
Horizontal Section Standard Element
MAXPARETE HSP PYRO MNP - Sheet 3.2 - Rev. 02
Core in Calcium Sulphate
Aluminium Profile covered with special fire resistant paint
Spacers in Calcium Sulphate
Reinforcing iron tubular1
10 m
m
Sections
Seal and Movement Standard Element
MAXPARETE HSP PYRO MNP - Sheet 3.3 - Rev. 01
CENTRAL MOVEMENT GROUP
UPPER SEAL GROUP
LOWER SEAL GROUP
Trolley/s
Sections
MAXPARETE HSP PYRO MNP - Sheet 3.4 - Rev. 01
Standard Element
Sections
MAXPARETE HSP PYRO MNP - Sheet 3.5 - Rev. 01
Self-bearing Standard Element
Multiple ElasticAdjustable Parts
Sections
MAXPARETE HSP PYRO MNP - Sheet 3.6 - Rev. 03
Vertical Upright - Horizontal Section
Finishing Profile
PVC Proflile
Aluminium Profile
110
mm
Elements
MAXPARETE HSP PYRO MNP - Sheet 4.1 - Rev. 01
Elements
Standard Element Expander Element
Pass Door Elementdoor thickness 106 mm
Elements
MAXPARETE HSP PYRO MNP - Sheet 4.2 - Rev. 02
Standard Element
The width of the elements is between 600 and 1200 mm.
Control
1135 m
m
Elements
MAXPARETE HSP PYRO MNP - Sheet 4.3 - Rev. 03
Expander Element
Control
146
110
The expander element is produced in two versions - MONODIRECTIONAL and MULTIDIRECTIONAL - with variable width (740 mm min / 1320 mm max) and with stroke from 100 to 170 mm.
SERIES
STROKE 100 mm
STROKE 170 mm
S
100
170
F
260
330
94
5 m
m
Elements
MAXPARETE HSP PYRO MNP - Sheet 4.4 - Rev. 01
Pass Door Element - Door thickness 106 mm
STANDARD DIMENSIONS
Panelwidth
1220 mm
Doorheight
2120 mm
Doorwidth
900 mm
Control
Sliding bar
TracksandCoverings
MAXPARETE HSP PYRO MNP - Sheet 5.1 - Rev. 02
Track Type 100 - With Covering
Intumescent Gasket
Gasket
Panels with Fire Resistant Core(Calcium Sulphate)
Intumescent Gasket
TracksandCoverings
MAXPARETE HSP PYRO MNP - Sheet 5.2 - Rev. 02
Track Type 800 - With Covering
Intumescent Gasket
Gasket
Panels with Fire Resistant Core(Calcium Sulphate)
Intumescent Gasket
MAXPARETE HSP PYRO MNP - Sheet 6.1 - Rev. 02
TracksAnchorageSystems
Track Anchorage with Iron Profile
Iron Profile(properly dimensioned)
Welding
MAXPARETE HSP PYRO MNP - Sheet 6.2 - Rev. 02
TracksAnchorageSystems
Track Anchorage with Rawplugs
M8 Screw min.(Rawplugs properly
dimensioned)
Reinforced Concrete Slab
MAXPARETE HSP PYRO MNP - Sheet 6.3 - Rev. 01
TracksAnchorageSystems
Track Anchorage with Rawplugs and Tensioners
Intermediate Plate
45° Min.
Square
50/1
00 m
m M
ax
Tensioner
Iron Tensioner
MAXPARETE HSP PYRO MNP - Sheet 6.4 - Rev. 01
TracksAnchorageSystems
Track Anchorage with Rawplugs and Stiffenings Plates
Stiffening Plate
Counterplate
Intermediate Plate(if applicable)
MAXPARETE HSP PYRO MNP - Sheet 6.5 - Rev. 01
TracksAnchorageSystems
"C" Profile
Suspended Track Anchorage
MAXPARETE HSP PYRO MNP - Sheet 7.1 - Rev. 01
StackingSchemes
Stacking Scheme “1MON”
Distended Wall
Stacking Schemeon the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.2 - Rev. 01
StackingSchemes
Stacking Scheme “2PDN”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.3 - Rev. 01
StackingSchemes
Stacking Scheme “2PAR”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.4 - Rev. 01
StackingSchemes
Stacking Scheme “2FAS”
Distended Wall
Stacking Schemeout the wall axis
150 mm
MAXPARETE HSP PYRO MNP - Sheet 7.5 - Rev. 01
StackingSchemes
Stacking Scheme “2FAL”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.6 - Rev. 01
StackingSchemes
Stacking Scheme “2FAM”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.7 - Rev. 01
StackingSchemes
Stacking Scheme “2PDR”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.8 - Rev. 01
StackingSchemes
Stacking Scheme “2AL1”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP PYRO MNP - Sheet 7.9 - Rev. 01
StackingSchemes
Stacking Scheme “2AL2”
Distended Wall
Stacking Schemeout the wall axis
TrolleysandTracks
Series 100 - Trolleys and Tracks
MAXPARETE HSP PYRO MNP - Sheet 8.1 - Rev. 02
TrolleysandTracks
Series 800 - Trolleys and Tracks
MAXPARETE HSP PYRO MNP - Sheet 8.2 - Rev. 02
IdeasforPlanning
Which space do I need to divide?
Which supporting structures do I need?
How many operable partitions do I need?
Which type of activity will be hold in the desired premises?
How much room is available to stack the movable wall elements?
MAXPARETE HSP PYRO MNP - Planning - 1
Oddicini Industrie S.p.A. offers a wide range of versions of MAXPARETE HSP PYRO MNP operable parti-tions, each one featuring its own range of options.
Before consulting your Oddicini agent we suggest you a planning that allows you to make the right choices and enables us to supply you with the product that best suit your requirements.
If you have to divide a specific area, you need to decide how many spaces you wish to create and their volumes. Once examined the existing space carefully, you should consider the elements that might interfere with the installation or the movement of the partitions, such as windows, columns, airconducts or pieces of furniture. You should assess if all the spaces you will create are suitably equipped with the services necessary for your activities. Is there a sufficient lighting system? Air conditioning? Electricity? All these considerations could lead to variations in the division you originally planned.
Most types of operable partitions are likely to depend on the load bearing elements (concrete soffits or ceilings) of the building. A verification of the soffit structure available or expected is necessary so to make sure it is fit for the anchorage of the system. In order to establish if the structure is adequate to support an operable partition it is sometimes advisable to consult a professional i.e. a structural engineer or an architect. In case the bearing structure was proved to be not suitable, there are self-supporting versions of the operable partitions adapted to transfer part of the total weight of the system to the floor so to lighten the weight applied to the soffit.
Estimate how many partitions will be necessary and their approximate dimensions; your Oddicini agent will help you at a second stage to precisely assess your requirements.
The answer to this question will enable us to determine the required level of acoustic performances. A classroom will require, for instance, a lesser need for acoustic insulation than a concert hall. The higher is the demand for acoustic insulation, the more expensive will be the operable partition.
It often happens that a high soundproofing is requested without taking into consideration the soundproofing of the area as a whole. The walls of a room where an operable partition is installed should not have a soundproofing level not lesser than the partition itself. For more specific details on acoustic performances, please ask for Oddicini Technical Anthology or our cd-rom.
The position of the stacking area can enormously influence the final layout of the operable partitions. Decide the areas where the wall elements will be stacked and parked when the wall is not in use.
Typically these are stored at one of the two extremities of the partition. If there is enough space, the elements of the wall can be moved in a dedicated area of collection by means of additional parts of track.
IdeasforPlanning
MAXPARETE HSP PYRO MNP - Planning - 2
Do I need special finishes?
Do I need special features?
The price of MAXPARETE HSP PYRO MNP is influenced by the type of finish. The standard finishes include raw calcium sulphate and high pressure laminates (HPL).
Special vinyl or fabric coverings are also available upon request.
Verify the safety features and standards to which the premises must conform to the required class of fire reaction and fire resistance of the partitions, the required number and dimensions of pass doors and/or emergency exits.