TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM …access-novello.com/userfiles/product_files_shared/BKS...
Transcript of TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM …access-novello.com/userfiles/product_files_shared/BKS...
-
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
1
CONTENTS1. BKS SLIDING SYSTEM OVERVIEW....................................................................................................................2. BKS SLIDING SYSTEM MANAGEMENT OF TAKING MEASURE.................................................................... 3. BKS SLIDING SYSTEM WITHOUT THRESHOLD CALCULATION................................................................... 3.1. GLASS CALCULATION GUIDE...........................................................................................................................3.2. BASE PROFILE CALCULATION METHOD........................................................................................................ 3.2.1 UPPER BASE PROFILE CALCULATION ...........................................................................................................3.2.2 LOWER BASE PROFILE CALCULATION .......................................................................................................... 3.3. GLASS SEAL CALCULATION GUIDE.................................................................................................................3.3.1 LENGTH CALCULATION OF INITIAL GLASS SEAL ........................................................................................ 3.3.2 LENGTH CALCULATION OF GLASS SEAL........................................................................................................ 3.4. SIDE COLUMN PROFILE CALCULATION METHOD....................................................................................... 3.5. LENGTH CALCULATION OF H TRANPARENT SEAL.......................................................................................3.6. FRAME PROFILE CALCULATION GUIDE........................................................................................................3.7. EXAMPLE OF CALCULATION............................................................................................................................4. PRODUCTION STEPS OF BKS SLIDING SYSTEM WITHOUT THRESHOLD.................................................4.1. NEEDED PARTS FOR INITIAL PANEL...............................................................................................................4.2. NEEDED PARTS FOR INTERMEDIATE PANEL................................................................................................5. PRODUCTION STEPS OF BKS SLIDING SYSTEMS WITHOUT THRESHOLD................................................5.1. INSTALLATED BKS SLIDING SYSTEM WITHOUT THRESHOLD....................................................................6. BKS SLIDING SYSTEM WITH THRESHOLD CALCULATION...........................................................................6.1. GLASS CALCULATION GUIDE...........................................................................................................................6.2. BASE PROFILE CALCULATION METHOD........................................................................................................ 6.2.1 UPPER BASE PROFILE CALCULATION ........................................................................................................... 6.2.2 LOWER BASE PROFILE CALCULATION ..........................................................................................................6.3. GLASS SEAL CALCULATION GUIDE.................................................................................................................6.3.1 LENGTH CALCULATION OF INITIAL GLASS SEAL ........................................................................................6.3.2 LENGTH CALCULATION OF GLASS SEAL........................................................................................................ 6.4. SIDE COLUMN PROFILE CALCULATION METHOD....................................................................................... 6.5. LENGTH CALCULATION OF H TRANPARENT SEAL....................................................................................... 6.6. FRAME PROFILE CALCULATION GUIDE........................................................................................................ 7. PRODUCTION AND ASSEMBLY STEPS OF BKS SLIDING SYSTEM WITH THRESHOLD............................8. SPECIFIC STAFF OF BKS SLIDING SYSTEM WITH THRESHOLD...............................................................8.1. NEEDED PARTS FOR INITIAL PANEL...............................................................................................................8.2. NEEDED PARTS FOR INTERMEDIATE PANEL................................................................................................ 9. INSTALLATED BKS SLIDING SYSTEM WITH THRESHOLD............................................................................
256677788899910111415161920202121212222222323232424252627
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
GLA
SS P
AN
ELS
HEIG
HT
GLASS PANELS WIDTH
2
1.BKS SLIDING SYSTEM OVERVIEW
GENERAL INFORMATION:
SLIDING SYSTEM WITH THRESHOLD SLIDING SYSTEM WITHOUT THRESHOLD
THE SLIDING SYSTEM DOESNT HAVE LIMIT OF GLASS PANELS. FOR SYSTEMS LONGER THEN 6 METER NUMBER OF PANELS CAN BE INCREASED BY THE ADDITION OF THE LOWER AND UPPER FRAME PROFILE.
MAXIMUM GLASS PANELS WIDTH : 1300 MMRECOMMENDED GLASS PANELS WIDTH : 1000 MMPANELS HEIGHT FOR 10 MM GLASS : 3000 MM PANELS HEIGHT FOR 8 MM GLASS : 3000 MM
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
AA
KESIT A-ALEK 1 : 10
INITIAL PANEL INITIAL
PANEL INTERMEDIATE
PANELMIDDLE PANEL
INTERMEDIATE PANEL
3
BKS SLIDING SYSTEM WITH THRESHOLD VIEW
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
INITIAL PANEL INITIAL
PANEL INTERMEDIATE
PANELMIDDLE PANEL
INTERMEDIATE PANEL
4
BKS SLIDING SYSTEM WITHOUT THRESHOLD VIEW
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
100
0
101
0
101
0
101
5
4000
5
2. BKS SLIDING SYSTEM MANAGEMENT OF TAKING MEASURE
TOP PARAPET
LASER
FLOOR
1. UPPER AND LOWER PARAPET ARE DEFINED USING CONSTRUCTION LASERS.2. MEASUREMENT SHOULD BE TAKEN WITH SAME LEVEL OF THE UPPER PARAPET OUTER EDGE.3. BOTTOM FRAME SHOULD BE MEASURED USING LASER REFER TO THE TOP OF THE PARAPET.
OPERATIONAL DEDUCTIBLE GAP IS 10 mm.
THE SYSTEM HEIGHT MUST BE TAKEN FROM THE TOP OF THE LOWEST POINT
NECESSARY DATA FOR THE BKS SLIDING SYSTEM :
LENGHT1.HEIGHT2.NUMBER OF PANELS3.PROFILE COLOR4.GLASS COLOR5.
TOP PARAPET
SIDE WALL
SIDE WALL
UP FRAME PROFILE
FLOOR
BOTTOM BASE
PROFILE
TOP PARAPET
FLOOR
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
100
0
101
0
101
0
101
5
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
875
508
AA
15,5 15,5 17 17 17 7 17 17 17
SYSTEM LENGHT = 4000
GLASS WIDTH=508
KESIT A-ALEK 1 : 10
2 PANELS PASS MIDDLE OF SYSTEM2 PANELS PASS2 PANELS PASS 2 PANELS PASS 2 PANELS PASS 2 PANELS PASS
RIGHT BEGINNING OF SYSTEM
LEFT BEGINNING OF SYSTEM
/
D
DE
KESIT D-D
SYS
TEM
HEI
GHT
= 1
000
GLA
SS H
EIG
HT =
875
DETAY ELEK 1 : 8
6
68,
5
9
DETAY FLEK 1 : 4
7,5
3
4
DETAY GLEK 1 : 4
3. BKS SLIDING SYSTEM WITHOUT THRESHOLD CALCULATION3.1. GLASS CALCULATION GUIDE:
EXAMPLE OF CALCULATION:FORMULA: GLASS WIDTH CALCULATION
SYSTEM LENGHT
4000 MM
LEFT BEGINNING OF SYSTEM
15.5 MM
RIGHT BEGINNING OF SYSTEM
15.5 MM
CENTER OF SYSTEM
7 MM- - - +INTERSECTING
PANEL * 17 COUNT
6 x 17102 MM
FORMULA: GLASS HEIGHT CALCULATION
SYSTEM HEIGHT
1000 MM
LOWER FRAME
PROFILE HEIGHT
9 MM
DISTANCE BETWEEN LOWER FRAME
PROF. AND LOWER
BASE PROF.
6 MM
DISTANCE BETWEEN GLASS AND
68.5 MM
DISTANCE BETWEEN BEGINNING OF UPPER BASE PROFILE AND
BEGINNING OF UPPER FRAME
PROFILE
34 MM
GLASS HEIGHT
875 MM
ALT BAZA YK.
86.5 MM
ALT BAZA CAM YUVA
YK.
18 MM
AST BAZAYK.
13.5 MM
ST BAZA CAM YUVA
YK.
6 MM
DISTANCE BETWEEN GLASS AND
BEGINNING OF UPPER BASE
PROFILE
7.5 MM- - - - =
SYSTEM HEIGHT
1000 MM - 125 MM GLASS HEIGHT875 MM-
=
6
PANEL NUMBER
8
ONE GLASSDIMENSION
508 MM=
GLASS DIMENSION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
GLASS WIDTH CALCULATION TABLE
FOR THE RIGHT AND LEFT BEGINNING OF SYSTEM 15.5 MM
FOR THE CENTER OF SYSTEM 7 MM
FOR THE PANELS PASS 17 MM
875
508
KATLANIR CAM SSTEMLER
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
D
D
F
KESIT D-D
GLA
SS W
IDTH
=508
UPP
ER B
ASE
PRO
FILE
LEN
GTH
=491
8,5
DETAY FLEK 1 : 5
BAR CONJOINING
CAP
BAR CONJOINING
CAP
UPPER BASE
PROFILE
GLASS
8,5
DETAY GLEK 1 : 1
8,5
J
J
K
KESIT J-J
DETAY KLEK 1 : 5
LL
MKESIT L-L
GLASS WIDTH=508 BASE PROFILE LENGHT=497
DETAY MLEK 1 : 5
8,5
DETAY OLEK 2 : 5
2,5
DETAY PLEK 2 : 3
WW
XKESIT W-W
GLASS WIDTH=508 BASE PROFILE LENGHT=491
DETAY XLEK 1 : 5
8,5
DETAY YLEK 1 : 2
8,5
DETAY ZLEK 1 : 2
3.2.BASE PROFILE CALCULATION METHOD
7
FORMULA: UPPER BASE PROFILE LENGTH CALCULATION
GLASS WIDTH
508 MM
INNER SPACE OF THE BAR
CONJOINING CAP
8,5 MM
ITA BRLETRME
KAPAK INNER SPACE OF
THE BAR CONJOINING
CAP
8,5 MM
UPPER BASE PROFILE LENGTH
491 MM- - =
FORMULA: LOWER BASE PROFILE LENGTH CALCULATION
1.FOR THE INITIAL AND MIDDLE PANELS;
2.FOR THE INTERMEDIATE PANELS;
3.2.1.UPPER BASE PROFILE CALCULATION
3.2.2.LOWER BASE PROFILE CALCULATION
FORMULA: LOWER BASE PROFILE LENGTH CALCULATION
GLASS WIDTH
508 MM
INNER SPACE OF THE MIDDLE AND
SIDE COLUMN CAPS
8,5 MM
INNER SPACE OF THE
INTERMEDIATE BASE CAPS
2,5 MM
LOWER BASE PROFILE LENGHT
497 MM=- -
GLASS WIDTH
508 MM
INNER SPACE OF THE
INTERMEDIATE BASE CAPS
8,5 MM
INNER SPACE OF THE
INTERMEDIATE BASE CAPS
8,5 MM
LOWER BASE PROFILE LENGHT
491 MM=--
ST BAZA
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)KATLANIR CAM SSTEMLER
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
L
L
K
K
M
KESIT K-K
GLA
SS H
EIG
HT =
875
ALU
M. S
EAL
LEN
GTH
=835
KESIT L-LLEK 1 : 9
GLA
SS H
EIG
HT =
875
INITI
AL
ALU
M. S
EAL
LEN
GTH
=832
.5
DETAY MLEK 1 : 9
24,
5
DETAY NLEK 1 : 3
18
DETAY OLEK 2 : 9
24,
5
DETAY PLEK 2 : 7
15,
5
DETAY QLEK 2 : 7
8
3.3.GLASS SEAL CALCULATION GUIDE3.3.1. LENGTH CALCULATION OF INITIAL GLASS SEAL
3.3.2. LENGTH CALCULATION OF GLASS SEAL
INITIAL ALUMINUM GLASS SEAL
GLASS HEIGHT
875 MM
GLASS GAP DIMENTION INTO BASE
PROFILE
18 MM
GLASS HEIGHT
875 MM
BASE INTERMEDIATE CAPS GAP
DIMENTION
15.5 MM
GLASS GAP DIMENTION INTO BAR
CONJOINING CAP
24.5 MM
GLASS GAP DIMENTION INTO BAR
CONJOINING CAP
24.5 MM
INITIAL ALUM.SEAL LENGTH
832.5 MM
ALUM.SEAL LENGTH
835 MM
- - =
ALUMINUM GLASS SEAL - - =
FORMULA: INITIAL ALUM. SEAL LENGTH CALCULATION
FORMULA: ALUM. SEAL LENGTH CALCULATION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
SID
E C
OLU
MN
PRO
FILE
LEN
GHT
=940
SYS
TEM
HEI
GHT
= 10
00
51
9
3.4. SIDE COLUMN PROFILE CALCULATION METHOD
9
SYSTEM HEIGHT
1000 MM
LOWER BASE PROFILE HEIGHT
9 MM
UPPER BASE PROFILE HEIGHT
51 MM
SIDE COLUMN PROFILE LENGHT
940 MM- - =
3.6. FRAME PROFILE CALCULATION GUIDE LOWER FRAME PROFILE
UPPER FRAME PROFILE
AS MENTIONED IN PART TAKING MEASURES, FRAME PROFILE MUST BE CUT AS SYSTEM LENGTH.
3.5. LENGTH CALCULATION OF H TRANPARENT SEAL
H SEAL IS UTLZED AT EDGES OF 2 MIDDLE PANELS. H SEAL LENGTH IS THE SAME AS FOR AN INITIAL ALUMINUM SEAL.
H-SEAL
FORMULA: SIDE COLUMN CALCULATION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
AA SYSTEM LENGHT = 4000
GLASS = 508
GLASS = 508
GLASS = 508
GLASS = 508 GLASS = 508
GLASS = 508
GLASS = 508
GLASS = 508
124
KESIT A-ALEK 1 : 10
PANELS COLLECTION WAY PANELS COLLECTION WAY
PANELS COLLECTION WAY
PANELS COLLECTION WAY
SYS
TEM
HEI
GHT
= 1
000
SID
E C
OLU
MN
PRO
FILE
LEN
GHT
= 9
40
ALU
M. S
EAL
LEN
GTH
= 8
35
IN
ITIA
L A
LUM
. SEA
L LE
NG
TH=8
32.5
LOWER BASE = 491 LOWER BASE = 497 LOWER BASE = 497
MIDDLE PANEL
MIDDLE PANEL
BB
KESIT B-BLEK 1 : 15
10
3.7.EXAMPLE OF CALCULATION
INTERMEDIATE PANEL
INTERMEDIATE PANEL
INTERMEDIATE PANEL
INTERMEDIATE PANEL
INITIAL PANEL
INITIAL PANEL
PANELS COLLECTION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
8
8
8
11
4. PRODUCTION STEPS OF BKS SLIDING SYSTEM WITHOUT THRESHOLD
1.STEP
UPPER BASE PROFILE CUTTINGUPPER BASE
PROFILE
UPPER BASE PROFILE MEASURES WAS OBTAINED BY DESCRIBED FORMULA IN CHAPTER UPPER BASE PROF. CALCULATION. THEN, FOR EACH PANEL ONLY 1 PIECE CAN BE CUT.
LOWER BASE PROFILE CUTTING2.
STEP LOWER BASE PROFILE OF INITIAL AND MIDDLE PANELS ARE DIFFERENT AS DESCRIBED IN CHAPTER LOWER BASE PROF. CALCULATION. ACCORDING TO THE VALUES, FOR EACH PANEL IS CUT ONLY ONE PIECE.
LOWER BASE PROFILE
3.STEP
INITIAL ALUM. SEAL AND H-SEAL CUTTING
INTERMEDIATE SEAL CUTTING4.
STEP
INITIAL ALUMINUM GLASS SEAL
SEAL CAN BE CUT REFER TO DESCRIBED FORMULA. INITIAL SEAL WILL BE INSTALLED ON INITIAL AND MIDDLE PANELS FROM THE OUTER EDGE
INTERMEDIATE SEAL CAN BE CUT REFER TO DESCRIBED FORMULA. THE SEAL WILL BE INSTALLED ON THE INTERMEDIATE PANELS FROM THE INNER EDGE.
ALUMINUM GLASS SEAL
H-SEAL
H SEAL LENGTH IS THE SAME AS FOR AN INITIAL ALUMINUM SEAL.
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
8
8
8
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
AB
DETAY ALEK 1 : 5
UPPER BASE
PROFILDETAY B
LEK 1 : 2
DETAY CLEK 1 : 2
D
DETAY DLEK 1 : 5
E
DETAY E
ST BAZA
ALT BAZA
CAM CAM
F
DETAY F
ST BAZA
ALT BAZA
G
DETAY GLEK 1 : 5
UPPER BASE PROFIL
BAR CONJOINING
CAP
DETAY HLEK 2 : 5
BAR CONJOINING
CAP
J
L
DETAY JLEK 1 : 5
LOWER BASE
PROFILE
INTERMEDIATE COVER
DETAY KLEK 1 : 3
INITIAL AND MIDDLE COVERS
M
DETAY MLEK 1 : 3
12
5.STEP
HOW TO INSTALL UPPER WHEEL TO UPPER BASE PROFIL
AT EACH UPPER BASE PROFILE AT THE EDGES UPPER WHEELS ARE MOUNTING. ONLY AFTER BAR CONJOINING CAP INSTALLATION, IT CAN BE TIGHTENED.
6.STEP
ST BAZA VE ALT BAZANIN CAMA TAKILMASI
ST BAZA VE ALT BAZA CAM YAPITIRICI YARDIMI LE CAMA MONTE EDLR.
UPPER WHEEL
UPPER WHEEL
HOW TO INSTALL BAR CONJOINING CAP TO BASE PROFIL
BAR CONJOINING CAPS TAKE PLACE ON THE UPPER BASE PROFILE END. CAPS ARE TIGHTENED WITH ALLEN WRENCH. AFTER INSTALL THE BAR CONJOINING CAP UPPER WHEELS CAN BE SCREWED TOO.
7.STEP
INITIAL AND MIDDLE CAPS INSTALLATION
INITIAL AND MIDDLE CAPS ARE MOUNTING TO THE INITIAL AND MIDDLE PANELS FROM ITS OUTSIDE BOTTOM CORNERS. NOW THIS CAPS CAN BE SCREWED TO BOTTOM BASE PROFILE
HOW TO INSTALL INTERMEDIATE CAPS TO BASE PROFIL
INTERMEDIATE CAPS ARE MOUNTING TO THE FOLLOWING PANELS FROM ITS BOTTOM CORNERS. NOW THIS CAPS CAN BE SCREWED TO BOTTOM BASE PROFILE
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
UPPER WHEEL
UPPER WHEEL
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
A
DETAY A
CAM
E
H
J
OO
R
KESIT O-O
T
DETAY TLEK 1 : 7
INTERMEDIATE COVER
LOWER BASE PROFILE
BOTTOM WHEEL
V
DETAY VLEK 1 : 5
BOTTOM WHEEL
W
DETAY WLEK 1 : 8
ALUMINUM GLASS SEAL
ALUMINUM GLASS SEAL
UPPER BASE PROFILE
LOWER BASE PROFILE
X
DETAY XLEK 1 : 2
BRUSH SEAL
INTERMEDIATE ALUMINUM SEAL
13
8.STEP
10.STEP
BOTTOM WHEELS SLIDE ON LOWER BASE PROFILE UNTIL INTERMEDIATE CAPS, AS SHOWN ON DRAWING. THEN ITS SCREWED.
CAM FTL
BALANGICAM FTL
BOTTOM WHEEL INSTALLATION
UPPER LOWER BASE PROFILE AND ALUMINUM SEAL INSTALLATION TO GLASS
LOWER BASE PROFILE IS GLUED TO GLASS.
PREPARED ALUMINUM SEAL WITH BRUSH SEAL ARE MOUNTED TO THE GLASS PANEL .IT MUST REACH TO CONJOINING BAR.
INSTEAD OF ALUMINUM SEAL, H-SEAL IS MOUNTED ON THE MIDDLE PANELS OPPOSITE EDGES.
BRUSH SEAL IS CUT TO LENGTH OF THE UPPER BASE PROFILE, AND INSERTS INTO IT.
BRUSH SEAL IS CUT TO LENGTH OF THE ALUMINUM SEA UNTIL CONJOINING BAR, AND INSERTS INTO IT.
9.STEP
BRUSH SEAL INSTALLATION TO UPPER BASE PROFILE OR ALUMINUM SEAL
GLASS
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
1
2 2
3
UPPER BASE PROFILE IS GLUED TO GLASS.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
W.6811
W.6826W.6826
W.6810
A
B
DETAY ALEK 1 : 2
DETAY BLEK 1 : 2
CC
KESIT C-C
14
4.1. NEEDED PARTS FOR INITIAL PANEL
GLASS
W.6811UPPER BASE PROFILE
ONLY ONE PIECE IS USED AT EACH GLASS PANEL
FROM SYSTEM TOP.
W.6813INITIAL ALUMINUM
SEAL
ITS USED ON THE OUTER EDGES OF INITIAL PANELS
AS INSULATION.
W.6812INTERMEDIATE ALUMINUM SEAL
ITS USED BETWEEN GLASS PANLES AS
INSULATION
W.6821UPPER WHEEL
ITS MOUNTED ON THE EACH EDGE OF THE
UPPER GLASS PROFILE, ENSURING BALANCE OF
THE SYSTEM.
W.6826BAR CONJOINING CAP
ITS MOUNTED ON THE EACH TOP EDGE OF THE GLASS PANEL.
W.6820BOTTOM WHEEL
ITS MOUNTED ON THE EACH EDGE OF THE LOWER GLASS PROFILE, PROVIDING
MOTION OF THE PANELS.
W.6824MIDDLE AND INITIAL
CAPS
ITS INSTALLED ON THE LOWER BASE PROFILE
AT THE END OR MIDDLE POINTS.
W.6823INTERMEDIATE BASE
CAPS
ITS MOUNTED ON THE LOWER BASE PROFIL IN ORDER TO DRAG
THE PANELS.
W.6810BOTTOM BASE PROFILE
ONLY ONE PIECE IS USED AT EACH GLASS PANEL FROM SYSTEM BOTTOM.
NEEDED PARTS OF MIDDLE AND INITIAL PANELS ARE SAME, EXCEPT AN INITIAL SEAL. INSTEAD OF INITIAL SEAL AT THE MIDDLE PANEL H-SEAL IS USED.
W.6813W.6812
W.6823W.6824
W.6820 Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
W.6821W.6821
W.6820
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
W.6823W.6823
W.6812
W.6812
W.6826
W.6826
W.6811
W.6810
GLASS
B
C
DETAY BLEK 1 : 3
DETAY CLEK 1 : 3
15
4.2. NEEDED PARTS FOR INTERMEDIATE PANEL
W.6821W.6821
W.6820W.6820
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
W.6811UPPER BASE PROFILE
ONLY ONE PIECE IS USED AT EACH GLASS PANEL
FROM SYSTEM TOP.
W.6810BOTTOM BASE PROFILE
ONLY ONE PIECE IS USED AT EACH GLASS PANEL FROM SYSTEM BOTTOM.
W.6812INTERMEDIATE ALUMINUM SEAL
ITS USED BETWEEN GLASS PANLES AS
INSULATION
W.6821UPPER WHEEL
ITS MOUNTED ON THE EACH EDGE OF THE
UPPER GLASS PROFILE, ENSURING BALANCE OF
THE SYSTEM.
W.6826BAR CONJOINING CAP
ITS MOUNTED ON THE EACH TOP EDGE OF THE GLASS PANEL.
W.6820BOTTOM WHEEL
ITS MOUNTED ON THE EACH EDGE OF THE LOWER GLASS PROFILE, PROVIDING
MOTION OF THE PANELS.
W.6823INTERMEDIATE BASE
CAPS
ITS MOUNTED ON THE LOWER BASE PROFIL IN ORDER TO DRAG
THE PANELS.
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
A
DETAY ALEK 1 : 20
SIDE COLUMNPROFILE
LOWER FRAME PROFILE
SIDE COLUMNPROFILE
UPPER FRAME PROFILE
BC
DETAY BLEK 1 : 6
LOWER FRAME PROFILEBOTTOM SIDE
COLUMN EQUIPMENT
DETAY CLEK 1 : 6
LOWER FRAME PROFILE
BOTTOM SIDE COLUMN
EQUIPMENT
DE
DETAY DLEK 1 : 8
UPPER SIDE COLUMN
EQUIPMENT
DETAY ELEK 1 : 8
SIDE COLUMNPROFILE
UPPER SIDE COLUMN
EQUIPMENT
F
DETAY FLEK 1 : 6
I
DETAY ILEK 1 : 5
J
DETAY JLEK 1 : 8
SIDE COLUMNPROFILE
16
5. PRODUCTION STEPS OF BKS SLIDING SYSTEMS WITHOUT THRESHOLD
1.STEP
2.STEP
THE SIDE COLUMN PROFILES ARE MOUNTED TO THE LOWER FRAME PROFILE BY BOTTOM SIDE COLUMN EQUIPMENT.
TOP FRAME PROFILE IS MOUNTED TO SIDE COLUMN PROFLE BY TOP SIDE COLUMN EQUIPMENT.
1
2
2
3
3
INSTALLATON CAN BE MADE EASIER IF ONE OF THE BASE INTERMEDIATE FLAT COVER AND LOWER WHEEL IS REMOVED. NOW THIS WHEEL CAN BE FIXATE TO THE BOTTOM FRAME RPOFILE.
ALT TEKER
ALT BAZA
BAZA ARA KAPAI
ALT TEKER
LOWER FRAME PROFILE
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
2
1
3AFTER SYSTEM NSTALLATION, TOP FRAME PROFILE
IS FIXED TO TOP PARAPATE AND BOTTOM FRAME PROFILE IS FIXED TO NETHER FLOOR WITH GLUE.4
FOR THE SYSTEM INSTALLATION LOWER FRAME PROFILE MUST BE PLACED ON A FLAT FLOOR.
ALTERNATVE 1
ALTERNATVE 2
TOP SIDE COLUMN APARATUS S FIXATED TO TOP FRAME PROFILE. TOP FRAME IS FICATED TO TOP PERAPETE WITH SCREW. TOP FRAME AND SIDE COLUMN APARATUS ARE MOUNTED WITH TOP SDE COLUMN APARATUS. AT THE SAME TIME SIDE COLUMNS AND LOWER FRAME INSTALLATION IS DONE WITH LOWER SIDE COLUMN APARATUS
BOTTOM WHEEL
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
A
DETAY ALEK 1 : 15
E
E
15-
20 M
M
KESIT E-ELEK 1 : 11
GII
JKESIT I-I
DETAY JLEK 1 : 11
L
DETAY LLEK 1 : 11
INTERMEDIATE COVER
2.PANEL
1.PANEL
DETAY MLEK 2 : 15
INTERMEDIATE COVER
N
DETAY NLEK 1 : 3
SCREW DIRECTION
RETURN WAY OF PANEL
O
DETAY OLEK 1 : 3
17
3.STEP
YOU SHOULD START INSTALLATION FROM ONE SIDE OF SYSTEM. THE TOP WHEEL OF THE PANELS IS PASSED TO TOP FRAME POFILE. ROM CAPS SIDE IN ORDER TO PROVIDE THE CONVENIENCE INSTALLATION, BOTTOM WHEEL PASSES THROUGH BOTTOM BASE PROFILE. BASE INTERMEDIATE COVER IS SCREWED TO THE BASE.
AFTER PANELS CONNECTED TO THE SYSTEM, BETWEEN THE TOP CASE AND TOP WHEEL TOLERANCE WLL BE 15-20 MM.
4.STEP
BOTTOM WHEEL
BOTTOM WHEEL
BAZA ARA KAPAI VE ALT TEKERLER ALT BAZADAN SKLR.
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
YOU CAN ADJUST GAPS BETWEEN THE GLASS PANELS BY USING WHEELS AS SHOWN AT THE PICTURE BELOW.
WHILE SECOND PANEL INSTALLATION IT MUST BE IN THE MIDDLE OF FIRST PANEL AS SHOWN N DRAWING. THEN INTERMEDIATE CAPS AND WHEELS CAN BE MOUNTED TO BOTTOM BASE PROFILE. FOR THE FUTHER PANELS PROCESS OF CAPS AND WHEELS MONTAGE IS SHOWN AT STEPS 5 AND 6.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
B
DETAY BLEK 1 : 5
SRME KIL FTL
CAM FTL PROFL
CAM FTL PROFL
MIDDLE PANEL
INITIAL PANEL
INITIAL PANEL
E
F
DETAY ELEK 1 : 11
BALANGI KANADI
DETAY FLEK 1 : 8
LOCK FASTENERS
LOCK
DETAY GLEK 1 : 6
LOCK FASTENERS
LOCK
I
DETAY ILEK 1 : 4
J
10
DETAY JLEK 1 : 2
K
R
DETAY KLEK 1 : 3
L
14
DETAY LLEK 1 : 2
M
DETAY MLEK 1 : 2
NN
O
KESIT N-N
DETAY OLEK 1 : 3
IT CAN BE INSTALLED AT INITIAL PANELS INTO SIDE COLUMN
IT CAN BE INSTALLED AT MIDDLE PANELS
IT CAN BE INSTALLED AT INITIAL PANELS OUTSIDE OF SIDE COLUMN
SEMIFINISHED CODE:Y.6822.01
SEMIFINISHED CODE:Y.6822.02
SEMIFINISHED CODE:Y.6822.03
P
DETAY PLEK 1 : 5
Q
DETAY QLEK 1 : 5
DETAY RLEK 1 : 8
LOCK
LOCK FASTENERS
S
T
DETAY SLEK 1 : 9
DETAY TLEK 1 : 8
18
7.ADIM6.ADIM
SRME KIL FTL TAKILAN CAM FTL PROFLLER KANATLARA TAKILIR. CAM FTLLER NCE ITA BRLETRME KAPAINA TAKILIR DAHA SONRA BAZA ARA KAPAINA VEYA ORTA VE YANDKME KAPAINA TAKILIR.
ORTADAK KANATLARIN BRBRNE BAKAN KISIMLARINA CAM FTL PROFLLER YERNE EFFAF H FTL TAKILIR.
SRME KIL FTL, CAM FTL PROFL LSNDEN ITA BRLETRME KAPAINA GEECEK KADAR UZUN KESLR. CAM FTL PROFLLERNE SRME KIL FTLLER TAKILIR. SRME KIL FTL TAKILDIKTAN SONRA UZUN OLAN PARASI KESLR.
5.STEP
BKS SLIDING SYST. LOCK IS MOUNTED ON THE MIDDLE AND INITIAL PANELS. LOCK FASTENERS IS DIFFERENT FOR TWO TYPE OF PANEL. BELOW YOU CAN FIND CODE OF FASTENERS.
ON ONE SIDE OF MIDDLE PANEL THE LOCK IS MOUNTED, ON OPPOSITE SIDE FASTENERS IS SCREWED.LOCK AND FASTENERS ARE MOUNTED TO THE SIDE COLUMN PANEL DEPENDING ON THE SYSTEM FORM.
INITIAL PANEL MAY CONCDE BETWEEN SDE COLUMNS OR IT MAY CAINCIDE EDGE OF SIDE COLUM. THIS TWO EXPLANATIONS ARE GVEN IN THE PICTURE.
CAM FTL PROFL
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
1-DOOR LOCK IS USED AS AN ALTERNATIVE LOCK AT MIDDLE PANELS.
2-DOOR LOCK IS USED AS AN ALTERNATIVE LOCK AT MIDDLE PANELS. IT CAN BE LOCKED FROM
INSIDE AND OUTSIDE
OR
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
UPPER FRAME PROFILE
INITIAL PANEL
INITIAL PANEL
MIDDLE PANEL MIDDLE
PANEL
INTERMEDIATE PANEL INTERMEDIATE PANEL
INTERMEDIATE PANEL INTERMEDIATE
PANEL
SIDE COLUMN PROFILE
SIDE COLUMN PROFILE
BOTTOM BASE
PROFILE
BB
KESIT B-BLEK 1 : 10
5.1 INSTALLATED BKS SLIDING SYSTEM WITHOUT THRESHOLD
19
LOCKLOCK
LOCK
H-SEALALUMINUM GLASS SEAL
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
508
848
AA
15,5 15,5 17 17 17 7 17 17 17
SYSTEM LENGHT = 4000 GLASS WIDTH=508
KESIT A-ALEK 1 : 10
2 PANELS PASS MIDDLE OF SYSTEM2 PANELS PASS2 PANELS PASS 2 PANELS PASS 2 PANELS PASS 2 PANELS PASS
RIGHT BEGINNING OF SYSTEMLEFT BEGINNING OF SYSTEM
/I
I
J
KESIT I-I
SYS
TEM
HEI
GHT
=100
0 G
LASS
HEI
GHT
=848
DETAY JLEK 1 : 8
7,5
34
DETAY LLEK 1 : 4
42
68,
5
DETAY MLEK 1 : 4
6. BKS SLIDING SYSTEM WITH THRESHOLD CALCULATION6.1.GLASS CALCULATION GUIDE :
EXAMPLE OF CALCULATION:FORMULA: GLASS WIDTH CALCULATION
SYSTEM LENGHT
4000 MM
LEFT BEGINNING OF SYSTEM
15.5 MM
RIGHT BEGINNING OF SYSTEM
15.5 MM
CENTER OF SYSTEM
7 MM- - - +
(PANEL SAYISI - 2) x 176 x 17
102 MM
=ONE GLASSDIMENSION
508 MM
FORMULA: GLASS HEIGHT CALCULATION
SYSTEM HEIGHT
1000 MM
LOWER FRAME PROFILE HEIGHT
42 MM
DISTANCE BETWEEN BOTTOM FRAME
PROFILE AND LOWER GLASS SURFACE
68.5 MM
DISTANCE BETWEEN BEGINNING OF UPPER BASE PROFILE AND
BEGINNING OF UPPER FRAME
PROFILE
34 MM
GLASS HEIGHT
848 MM
ALT BAZA YK.
86.5 MM
ALT BAZA CAM YUVA
YK.
18 MMAST BAZA
YK.
13.5 MM
ST BAZA CAM YUVA
YK.
6 MM
DISTANCE BETWEEN GLASS AND
BEGINNING OF UPPER BASE
PROFILE
7.5 MM
- - - =SYSTEM HEIGHT
1000 MM - 152 MM GLASS HEIGHT848 MM
-=
20
INTERSECTING PANEL * 17 COUNT
6 x 17102 MM
PANEL NUMBER
8
GLASS DIMENSION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
GLASS WIDTH CALCULATION TABLE
FOR THE RIGHT AND LEFT BEGINNING OF SYSTEM 15.5 MM
FOR THE CENTER OF SYSTEM 7 MM
FOR THE PANELS PASS 17 MM
KATLANIR CAM SSTEMLER
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
D
D
F
KESIT D-D
GLA
SS W
IDTH
=508
UPP
ER B
ASE
PRO
FILE
LEN
GTH
=491
8,5
DETAY FLEK 1 : 5
BAR CONJOINING
CAP
BAR CONJOINING
CAP
UPPER BASE
PROFILE
GLASS
8,5
DETAY GLEK 1 : 1
8,5
J
J
K
KESIT J-J
DETAY KLEK 1 : 5
LL
MKESIT L-L
GLASS WIDTH=508 BASE PROFILE LENGHT=497
DETAY MLEK 1 : 5
8,5
DETAY OLEK 2 : 5
2,5
DETAY PLEK 2 : 3
WW
XKESIT W-W
GLASS WIDTH=508 BASE PROFILE LENGHT=491
DETAY XLEK 1 : 5
8,5
DETAY YLEK 1 : 2
8,5
DETAY ZLEK 1 : 2
6.2.BASE PROFILE CALCULATION METHOD
21
GLASS WIDTH
508 MM
INNER SPACE OF THE BAR
CONJOINING CAP
8,5 MM
ITA BRLETRME
KAPAK INNER SPACE OF
THE BAR CONJOINING
CAP
8,5 MM
UPPER BASE PROFILE LENGTH
491 MM
- - =
FORMULA: LOWER BASE PROFILE LENGTH CALCULATION
1.FOR THE INITIAL AND MIDDLE PANELS;
2.FOR THE INTERMEDIATE PANELS;
6.2.1. UPPER BASE PROFILE CALCULATIONI
6.2.2.LOWER BASE PROFILE CALCULATION
FORMULA: LOWER BASE PROFILE LENGTH CALCULATION
GLASS WIDTH
508 MM
INNER SPACE OF THE MIDDLE AND
SIDE COLUMN CAPS
8,5 MM
INNER SPACE OF THE
INTERMEDIATE BASE CAPS
2,5 MM
LOWER BASE PROFILE LENGHT
497 MM=- -
GLASS WIDTH
508 MM
INNER SPACE OF THE
INTERMEDIATE BASE CAPS
8,5 MM
INNER SPACE OF THE
INTERMEDIATE BASE CAPS
8,5 MM
LOWER BASE PROFILE LENGHT
491 MM=--
ST BAZA
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
FORMULA: UPPER BASE PROFILE LENGTH CALCULATION
KATLANIR CAM SSTEMLER
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
L
L
K
K
M
KESIT K-K
GLA
SS H
EIG
HT =
848
MID
DLE
ALU
M. S
EAL
LEN
GTH
=808
KESIT L-LLEK 1 : 9
GLA
SS H
EIG
HT =
848
INITI
AL
ALU
M. S
EAL
LEN
GTH
=805
.5
DETAY MLEK 1 : 9
24,
5
DETAY NLEK 1 : 3
18
DETAY OLEK 2 : 9
24,
5
DETAY PLEK 2 : 7
15,
5
DETAY QLEK 2 : 7
22
6.3. GLASS SEAL CALCULATION GUIDE6.3.1. LENGTH CALCULATION OF INITIAL GLASS SEAL
6.3.2. LENGTH CALCULATION OF GLASS SEAL
INITIAL ALUMINUM GLASS SEAL
GLASS HEIGHT
848 MM
GLASS GAP DIMENTION INTO BASE
PROFILE
18 MM
GLASS HEIGHT
848 MM
BASEINTERMEDIATE
CAPS GAP DIMENTION
15.5 MM
GLASS GAP DIMENTION INTO BAR
CONJOINING CAP
24.5 MM
GLASS GAP DIMENTION INTO BAR
CONJOINING CAP
24.5 MM
INITIAL ALUM. SEAL LENGTH
805.5 MM
MIDDLE ALUM. SEAL LENGTH
808 MM
- - =
ALUMINUM GLASS SEAL - - =
FORMULA: ALUM. SEAL LENGTH CALCULATION
FORMULA: INITIAL ALUM. SEAL LENGTH CALCULATION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
SYSTEM LENGHT=4000
BOTTOM BASE LENGTH=3980
UPPER FRAME LENGTH=4000
BC
10
DETAY BLEK 1 : 15
LOWER FRAME PROFILE
SIDE COLUMN PROFILE
BOTTOM SIDE COLUMN EQUIPMENT
10
DETAY CLEK 1 : 9
LOWER FRAME PROFILE
SIDE COLUMN PROFILE
BOTTOM SIDE COLUMN
EQUIPMENT
D
DETAY DLEK 1 : 10
E
928
100
0
22
51
DETAY ELEK 1 : 10
23
LOWER FRAME PROFILE
SYSTEM LENGHT
4000 MM
BOTTOM SIDE COLUMN
EQUIPMENT WIDTH
10 MM
BOTTOM SIDE COLUMN
EQUIPMENT WIDTH
10 MM
LOWER FRAME PROFILE HEIGHT
3980 MM=--
6.4. SIDE COLUMN PROFILE CALCULATION METHOD
6.5. LENGTH CALCULATION OF H TRANPARENT SEAL
H SEAL IS UTLZED AT EDGES OF 2 MIDDLE PANELS. H SEAL LENGTH IS THE SAME AS FOR AN INITIAL ALUMINUM SEAL.
6.6. FRAME PROFILE CALCULATION GUIDEAS MENTIONED IN PART TAKING MEASURES, FRAME
PROFILE MUST BE CUT AS SYSTEM LENGTH.
H-SEAL
SYSTEM HEIGHT
1000 MM
BOTTOM SIDE COLUMN
EQUIPMENT HEIGHT
22 MM
UPPER BASE PROFILE HEIGHT
51 MM
SIDE COLUMN PROFILE LENGHT
928 MM=--
FORMULA: SIDE COLUMN CALCULATION
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
24
7. PRODUCTION AND ASSEMBLY STEPS OF BKS SLIDING SYSTEM WITH THRESHOLD
PRODUCTION STEPS FOR SLIDING SYSTEMS WITH/WITHOUT THRESHOLD ARE SAME. FOR SYSTEM WITH THREHOLD ONLY FOLLOWING ITEMS ARE DIFFERENT: INITIAL AND SIDE COLUMN CAPS, INTERMEDIATE CAPS, LOWER BASE PROFILE AND BOTTOM WHEELS. THEIR APPLICATION IS THE SAME AS IN A SYSTEM WITHOUT THRESHOLD.
INSTALLATON STEPS ARE SAME FOR SLDNG SYSTEMS WTH THRESHOLD AND WTHOUT THRESHOLD.
8. SPECIFIC STAFF OF BKS SLIDING SYSTEM WITH THRESHOLD
W.6920BKS BOTTOM WHEELS OF SLIDE
SYS. WITH THRESHOLD
W.6903BKS BOTTOM BASE PROFILE OF
SLIDE SYS. WITH THRESHOLD
W.6900BKS BOTTOM FRAME PROFILE
OF SLIDE SYS. WITH THRESHOLD
W.6923BKS INTERMEDIATE CAP OF
SLIDE SYS. WITH THRESHOLD
W.6924BKS INITIAL AND SIDE COLUMN CAP
OF SLIDE SYS. WITH THRESHOLD
W.6925BKS BOTTOM SIDE COLUMN EQUIPMENT
OF SLIDE SYS. WITH THRESHOLD
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
GLASS
W.6826
W.6811
W.6812W.6813
W.6826
W.6903
W.6924
W.6923
B
DETAY BLEK 1 : 5
C
DETAY CLEK 1 : 5
25
8.1. NEEDED PARTS FOR INITIAL PANEL NEEDED PARTS OF MIDDLE AND INITIAL PANELS ARE SAME, EXCEPT AN INITIAL SEAL. INSTEAD
OF INITIAL SEAL AT THE MIDDLE PANEL H-SEAL IS USED.
W.6920BOTTOM WHEELS WITH THRESHOLD
ITS MOUNTED ON THE EACH EDGE OF THE LOWER GLASS PROFILE, PROVIDING
MOTION OF THE PANELS.
W.6821W.6821
W.6920W.6920
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
W.6811UPPER BASE PROFILE
ONLY ONE PIECE IS USED AT EACH GLASS PANEL
FROM SYSTEM TOP.
W.6813INITIAL ALUMINUM
SEAL
ITS USED ON THE OUTER EDGES OF INITIAL PANELS
AS INSULATION.
W.6812INTERMEDIATE ALUMINUM SEAL
ITS USED BETWEEN GLASS PANLES AS
INSULATION
W.6821UPPER WHEEL
ITS MOUNTED ON THE EACH EDGE OF THE
UPPER GLASS PROFILE, ENSURING BALANCE OF
THE SYSTEM.
W.6826BAR CONJOINING CAP
ITS MOUNTED ON THE EACH TOP EDGE OF THE GLASS PANEL.
W.6824MIDDLE AND INITIAL
CAPS
ITS INSTALLED ON THE LOWER BASE PROFILE
AT THE END OR MIDDLE POINTS.
W.6823INTERMEDIATE BASE
CAPS
ITS MOUNTED ON THE LOWER BASE PROFIL IN ORDER TO DRAG
THE PANELS.
W.6903BOTTOM BASE
WITH THRESHOLD
ONLY ONE PIECE IS USED AT EACH GLASS PANEL FROM SYSTEM BOTTOM
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
GLASS
W.6826 W.6826
W.6811
W.6812 W.6812
W.6923
W.6903
W.6923
B
A
DETAY ALEK 1 : 4
DETAY BLEK 1 : 4
26
8.2. NEEDED PARTS FOR INTERMEDIATE PANEL
W.6903BOTTOM BASE
WITH THRESHOLD
ONLY ONE PIECE IS USED AT EACH GLASS PANEL FROM SYSTEM BOTTOM
W.6821 W.6821
W.6920W.6920
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
W.6811UPPER BASE PROFILE
ONLY ONE PIECE IS USED AT EACH GLASS PANEL
FROM SYSTEM TOP.
W.6812INTERMEDIATE ALUMINUM SEAL
ITS USED BETWEEN GLASS PANLES AS
INSULATION
W.6821UPPER WHEEL
ITS MOUNTED ON THE EACH EDGE OF THE
UPPER GLASS PROFILE, ENSURING BALANCE OF
THE SYSTEM.
W.6826BAR CONJOINING CAP
ITS MOUNTED ON THE EACH TOP EDGE OF THE GLASS PANEL.
W.6823INTERMEDIATE BASE
CAPS
ITS MOUNTED ON THE LOWER BASE PROFIL IN ORDER TO DRAG
THE PANELS.
W.6920BOTTOM WHEELS WITH THRESHOLD
ITS MOUNTED ON THE EACH EDGE OF THE LOWER GLASS PROFILE, PROVIDING
MOTION OF THE PANELS.
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -
-
INITIAL PANEL INTERMEDIATE
PANEL INTERMEDIATE PANEL
INTERMEDIATE PANEL INTERMEDIATE
PANEL
MIDDLE PANEL MIDDLE
PANELINITIAL PANEL
UPPER FRAME PROFILE
SIDE COLUMN PROFILE
SIDE COLUMN PROFILE
BOTTOM BASE PROFILE WITH
TRESHOLDH-SEAL
ALUMINUM GLASS SEAL
27
9. INSTALLATED BKS SLIDING SYSTEM WITH THRESHOLD
LOCK
LOCK
LOCK
Bu izimin Verisine V018 Veri Dosyasndan Ulaabilirsiniz.
TECHNICAL CATALOGUE OF BKS SLIDING SYSTEM WITHOUT/WITH THRESHOLD (8 and 10 mm)
PUBLICATION DATE : 27.11.2015 REVISION NUMBER : 000DOCUMENT NUMBER : TP004-02 REVISION DATE : -