TECHNICAL CATALOGUE - HAS · 230-400 V 50 Hz. / 280-480 V 60 Hz Rated current (400 V 50 Hz) 4.5 A...

42
1 fax e-mail internet + 39 / 059 / 8080811 + 39 / 059 / 908204 [email protected] www.torex.it TOREX S.p.A. Via Canaletto, 139/A I-41030 S. Prospero s/S (MO) - Italy Manual No. TOR.007.--.T.EN Issue: A Latest update: January 2017 ORIGINAL INSTRUCTIONS IN ENGLISH BUILT -IN FILTER LOADING BELLOWS TECHNICAL CATALOGUE BELLOJET ® EN

Transcript of TECHNICAL CATALOGUE - HAS · 230-400 V 50 Hz. / 280-480 V 60 Hz Rated current (400 V 50 Hz) 4.5 A...

1

faxe-mail

internet

+ 39 / 059 / 8080811+ 39 / 059 / [email protected]

TOREX S.p.A. Via Canaletto, 139/AI-41030 S. Prospero s/S(MO) - Italy

Manual No. TOR.007.--.T.EN Issue: A Latest update: January 2017

ORIGINAL INSTRUCTIONS IN ENGLISH

BUILT -IN FILTER LOADING BELLOWS

TECHNICALCATALOGUE

BELLOJET®EN

All the products described in this catalogue are manufactured according to TOREX S.p.A. Quality System procedures. The Company’s Quality System, certified according to ISO 9001-2008 guarantees that the entire production process, from the customer’s order to the after sales service, can fulfil the product quality standard.

This publication cancels and replaces any previous edition and revision. We reserve the right to implement modifications without notice.

This catalogue cannot be reproduced, even partially, without prior written consent by the Manufacturer.

INDEX

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

III

1.0 DESCRIPTION AND TECHNICAL FEATURES ....................................................................................... 1 1.1 Description ........................................................................................................................................ 1 1.2 Technical features ............................................................................................................................. 2 1.3 Improper use not permitted ............................................................................................................... 32.0 STANDARD VERSION OF THE MACHINE AND OPTIONS ................................................................... 4 2.1 Standard machine description ........................................................................................................... 4 2.2 Versions - Order code ....................................................................................................................... 6 2.3 Main components and accessories ................................................................................................... 8 2.4 Spreader ......................................................................................................................................... 213.0 DIMENSIONS AND WEIGHTS .............................................................................................................. 26 3.1 Head section overall dimensions .................................................................................................... 26 3.2 Flange dimensions .......................................................................................................................... 27 3.3 Terminal overall dimensions ............................................................................................................ 28 3.4 Bellows lengths ............................................................................................................................... 294.0 INQUIRY FORM ..................................................................................................................................... 36

TABLE OF CONTENTS

1.0 DESCRIPTION AND TECHNICAL FEATURES

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

1

Bellojet® Loading Bellows are the ideal solution for continuous, efficient, dust-free loading of dry, dusty bulk solids.Bellojet can be used for: - loading of tankers - loading of open trucksInside the upper head, the loading bellows BELLOJET® feature a filter provided with fan having the role to increase the filtration efficiency.

1.1 Description

1.0 DESCRIPTION AND TECHNICAL FEATURES

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

2

1.2 Technical features

General data sheet

Throughput DN300 (ZA,ZB,ZC,ZD,ZE,ZF) 250 m3/h

Process temperatureS (STANDARD)

-20°C +40°C"

Neoprene Hypalon - Polyester -20°C +120°CKevlar -20°C +200°C

Lift motor

Main data Size 80, B3, 0.55 kW, 1400 rpm, IP55, Ins.Class.F

Power supply 230-400 V 50Hz / 260-440V 60Hz

Rated current (380 V 50 Hz) 1.6 A

cos phi 0,75

Efficiency 71%

Filter unit

Long cartridges Short cartridges

Length 405 mm 200 mm

Number of cartridges 8 8

Filtering surface 10 m2 5 m2

Number of solenoid valves 4 4

Voltage solenoid valves 24 V AC 24 V AC

Solenoid valves power draw 0.220 A 0.220 A

Solenoid valves power 11 VA 11 VA

Cleaning interval 28 sec 28 sec

Cleaning time 100 msec 100 msec

Air tank volume 5.7 LITRI 5.7 LITRI

Operating pressure 6 bar 6 bar

Air consumption 4.5 Nm3/h 4.5 Nm3/h

Noise 78 dbA 78 dbA

Ambient temperature (STANDARD)

Lower ambient and process temperatures as an option

Electric suction unit motor

Size 90, B3-B5, 2.2 kW, 2800 rpm, IP55, Ins.Class.F. IE2

230-400 V 50 Hz. / 280-480 V 60 Hz

Rated current (400 V 50 Hz) 4.5 A

0,85

83%

Main data

Power supply

cos phi

Efficiency

Permitted air flow temperature

Permitted maximum static pressure on the filter body

-20°C ÷ +80°C

-0,05 bar ÷ 0,075 bar

All dimensions are expressed in mm unless otherwise specified.

1.0 DESCRIPTION AND TECHNICAL FEATURES

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

3

The machine has not been designed to operate in hazardous conditions or with hazardous materials; in case the machine must fulfil such requirements, it is mandatory to inform the manufacturer. - The materials considered as being hazardous are the following: explosive, toxic, flammable, harmful or

similar.

1.3 Improper use not permitted

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

4

2.1 Standard machine description

Pos. DENOMINAZIONE

1 Flange

2 Suction fan

3 End bearing assembly

4 External bellows

5 Grip

6 Conical end

7 Level indicator cone

8 Level indicator

9 Internal bellows

10 Filter element

11 Electric lift

12 Slack cable contact

13 Identification plate

14 Electric panel

15 Air cleaning system

16 Bottom closure cone

17 Bottom closure cone bellows

18 Open truck terminal

19 Skirt for ZC-ZD version

20 Skirt for ZE-ZF version

ZA-ZB

1

23

4

9

56

78

10

1112

13

14

15

16

17

402,06

ZC-ZD ZE-ZF

818

19

17

20

165678

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

5

2.1.1 COMPONENTS DESCRIPTION1) Flange: used for connecting loading bellows to an existing connection flange.

2) Suction fan (only for loading bellows with built-in dust filters): removes the air column saturated with dust from the interspaces between the two bellows by forcing the passage through the filters.

3) Body (only for loading bellows with built-in dust filters): contains the 8 replaceable filter cartridges.

4) External bellows: protects the internal bellows from possible damage.

5) Grip: provided for an easy handling of the conical end.

6) Conical end: coated with soft synthetic material and placed on the tanker inlet to prevent leakage of dusts.

7) Level probe cone: contains the level probe and disperses the material.

8) Level probe: provided with a rotary blade, it interrupts flow when the level of material already deposited touches the blade.

9) Inner bellows: the product falls into these bellows up to the tanker inlet opening.

10) Filter cartridge (only for loading bellows with built-in dust filters): the filter cartridges, together with the suction fan and air cleaning system, ensure loading without emission of dusts.

11) Drive unit: raises and lowers the end section.

12) Slack cable contact: when the conical end is rested on the tanker opening, the hoist cable becomes slack allowing the slackened cable contact to press the limit stop. This stops slackening of the cable.

13) Identification plate: shows the following data: serial number, type and year of manufacture; must always be indicated for ordering spare parts.

14) Control panel: may be on board the machine or remote; contains the operating logic electric circuits.

15) Air cleaning system: cleans the filter cartridge.

16) Bottom closure cone: prevents dust from leaking out of the loading bellows when the tanker is discon-nected to avoid dust dispersal around the loading bellows.

17) Bottom closure cone bellows: connects the bottom closure cone to the unloading cone.

18) Open truck terminal: equipped with feet to rest on the bottom of the open trucks.

19) Skirt for ZC-ZD version: avoids dispersion of dust into the environment.

20) Skirt for ZE-ZF version: has tapered shape for double use on tanker and open trucks

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

6

2.2 Versions - Order code

05 =07 =10 =12 =15 =17 =20 =22 =25 =27 =30 =32 =35 =

A Small cones 60 30D SS 304 small cones 60 30O HARDOX 400 small cones 60 300 Without cones

B 2 Neoprene-Hypalon bellows 60 30G 2 Neoprene bellows for food applications 60 30N Double Kevlar 60 30

M steelA SS 304H HARDOX 400

A with filter for tankerB with short filter for tankerC with filter for open truckD with short filter for open truckE with filter for tanker and open truckF with short filter for tanker and open truck

Z Standard

B 0 1

VER

SIO

N

5Z A M

LOAD

ING

BEL

LOW

TYP

E

MAT

ERIA

L O

F TH

E PA

RTS

IN C

ON

TAC

T W

ITH

TH

E PR

OD

UC

T

BELL

OW

S TY

PE A

ND

MAT

ERIA

L

CO

NES

TYP

E AN

D M

ATER

IAL

Ord

er fo

rm (s

ee le

ngth

s ta

ble)

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

7

PAINTING1 External yellow (3003A)2 External RAL1013 (3003B)3 External RAL1015 (3003C)4 External RAL 5010 (3003D) "STD"5 External RAL 5015 (3003E)6 External RAL 6011 (3003F)7 External RAL 7035 (3003G)8 External RAL 7032 (3003H)9 External RAL 7001 (3003I)A External RAL 9001 (3003L)B External RAL 9002 (3003M)C External RAL 9010 (3003N)E External Ecological (3003X)

0 Without filter1 Polyester PP Filter Cartridge4 Cartridges made from PV5 Cartridges made from PT

1 Junction box 2 Control panel and pushbutton panel*3 Junction box and pushbutton panel (*) If supplied, the control panel is powered at 400V 50Hz- 460V 60Hz, IP55

0 Without bottom closure cone1 With bottom closure cone2 Without bottom closure cone with vibrator3 With bottom closure cone and vibrator4 Pneumatic bottom closure cone

0 Without level indicator1 Rotary 24 VAC2 Rotary 48 VAC3 Rotary 110 VAC4 Rotary 230 VAC7 Vibrations8 Rotary 24 VDCJ Double vibrationM Double rotary 230 Vac (Solo ZC-ZD) K Double rotary 24 VACO Double rotary 24 VDC

1 380-420V 50 Hz2 440-480V 60Hz

N Drive 0,55 KwS Drive 0,55 Kw IP65T Drive 0,55 Kw (primary made)

1 4

DR

IVE

UN

IT

N 1 1 1 2C

ON

TRO

L P

AN

EL

AN

D M

OTO

RS

VO

LTA

GE

VIB

RA

TIN

G

LOA

DIN

G A

CC

ES

SO

RIE

S

ELE

CTR

ICA

L S

YS

TEM

CAR

TRID

GES

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

8

2.3 Main components and accessories

2.3.1 EMERGENCY HANDWHEEL

2.3.2 BELLOWS

Available in the following versions:

Bellows type Antistatic Operation temperatureNEOPRENE® HYPALON® YES From -20°C to +120°CFOOD GRADE POLYESTER YES From -20°C to +120°CKEVLAR® NO From -40°C to +200°C

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

9

2.3.3 ELECTRICAL CONTROL PANELThe control panel manages automatically the operation cycle of the loader and the filter cleaning cycle.The standard version comes in power version 400V 50Hz / 460V 60Hz, and protection degree IP55.

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

10

2.3.4 JUNCTION BOX

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

11

2.3.5 PENDANT PUSHBUTTON PANEL WITH CABLE

1

2

3

4

5

6

7

2.3.6 WIRELESS PUSHBUTTON PANEL

1 Control panel

2 Remote receiving unit

3 Wire connection betweenreceiver and panel

4 100m max rated distance

5 Remote control

6 Control panel

7 Remote receiving unit

Standard pushbutton for version with junction box

Standard pushbutton for version with control panel

The standard length of the pushbutton panels cable is 10 meters.

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

12

2.3.7 SKIRT FOR TANKER AND OPEN TRUCK LOADING BELLOWS (ZE-ZF)

2.3.8 VIBRATOR AT THE OUTLETThe vibrator fitted at the outlet eases the loading of poorly flowing materials which tend to clog.LOADING BELLOWS FOR TANKERS (ZA-ZB)LOADING BELLOWS FOR TANKER AND OPEN TRUCK (ZE-ZF)

In case the loader is used in OPEN TRUCK mode, the bottom closure cone (if provided) has to be opened us-ing the special hooks (see paragraph 3.4.3).

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

13

LOADING BELLOWS FOR OPEN TRUCK (ZC-ZD)

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

14

2.3.9 LEVEL INDICATORSThey indicate whether the tanker is full, or, in case of open trucks, they allow the step by step ascending of the loading bellows.

LOADING BELLOWS FOR TANKERSThe level indicators can be of the rotary or vibrating type:

Rotary level indicator Vibrating Level Indicator

LOADING BELLOWS FOR OPEN TRUCKThe loading bellows for open truck is equipped with 2 level indicators positioned 180° from each other. In this case too they can be of the rotary or vibrating type:

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

15

Fixed inner cone

BellowsHYPALON

NEOPRENE

CLOSED BOTTOM CONE OPENED BOTTOM CONE

Coated cone in SIN®TEX

mobile

Level indicator bearing cone

2.3.10 BOTTOM CLOSURE CONE (ONLY FOR ZA-ZB AND ZE-ZF OPEN TRUCK VERSION)

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

16

CLOSED BOTTOM CONE OPENED BOTTOM CONE

2.03.11 BOTTOM CLOSURE CONE (ONLY FOR ZA-ZB AND ZE-ZF TANKER VERSION)

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

17

2.3.12 REMOVABLE TERMINAL FOR OPEN TRUCK/TANKER

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

18

pt: overall pressure inside the circuit pd: dynamic pressure ps: static pressure

NOTE: The fan flow rate is calculated on the basis of the static pressure curves.

Fan performance curves

2.3.13 FILTER UNIT

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

19

NOTE: For further ore information see “Filter Media” and “Selection Criteria” Catalogues.

Filtering media

Cartridges

A

4

1

3

• 2

Filtering media

To meet the applications requirements in different industrial sectors, for all filter elements it is possible to use different types of filtering media. The WAM® filtering media are strictly certified by the Institute for the Work-place Safety “BIA” (Germany).

TYPE ITEM DESCRIPTION MATERIAL H

CARTDRIGE

1 Filtering media Polyester non-woven

405200

2 Head Thermoplastic material3 Bottom

4 BandA

WAM®

Code MATERIAL Gr./m2 FIELDS OF APPLICATION ClassBIA

P L E AT E D

PP Pleated non-woven polyester 265 Filtration of standard materials (above 70μm) M

PA Pleated non-woven polyester 265 Filtration of materials that are charged electrostatically M

PV Pleated non-woven polyester water repellent 265 Filtration of materials containing moisture and/or oils M

PTPTFE

Pleated non-woven polyester membrane 280 External filtration M

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

20

Blowing unitIt consists of:

- Solenoid vales (5) fitted inside the tank to reduce pressure drop (3);- Blowing pipes (1) connected to the tank fittings (2);- Externally anodized aluminium air tank with two heads (4) also made from aluminium with black matte cata-

phoresis finishing;- Air inlet (4);- Condensation drain tap (6).

The electronic timer manages sequentially the compressed air flow to the blowing pipes. The filter requires the connection to compressed air pipe at constant 6 bar.The compressed air must be clean, de-moist and oil free.

Air pulse-jet cleaning system

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

21

The spreader is positioned near the outlet spout in loaders for loading to tankers. It is particularly suitable for use with powdery, light materials since, owing to the rotation of a fan, the material is distributed uniformly inside the tanker allowing entry of a larger quantity of material.

Fig. 1

2.4 Spreader

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

22

GENERAL LAYOUT

1

2

3

4

5

6•

7 •

8•

Fig. 2

1 Electric panel

2 VMX01G pneumatic panel

3 Motor power cable

4 Level indicator cable

5 Level indicator holder

6 Motor air supply tube

7 Level indicator forks

8 Counterweight

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

23

Fig.3

The spreader consists of the following parts:1) Control panelIf the spreader is supplied, in addition to all the operating logic of the loading bellows, the electric panel also contains the operating logic for the spreader and an indicator light on the alarm panel front to signal the alarm if the pressure in the pneumatic panel is less than 1 bar.

2) Pneumatic control panel VMX01GIt is used for sending air into the motor protection cone to cool the motor.It consists of (see Fig. 3):

ItemPos. N° Descrizione

1 1 Pressure gauge

2 1 Pressure reducer

3 1 N.C. 3-way solenoid valve with 24 V 50-60 Hz coil

4 1 Pressure switch set at 1 bar

5 2 Air discharge

6 1 8x6 quick-fit coupling forconnection to spreader cone

7 1 PG 9 Cable gland for pressureswitch connection cable

8 1 8 x 6 quick-fit connection for airinlet

9 1 PG 9 cable gland for solenoidvalve connection

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

24

3) Motor air feeding pipeIt is a spiralled tube, 8x6 mm diameter, integral with the outer bellows connected to pneumatic panel, VMX01G, on one side and the spreader cone on the other side. It conveys cooling air to the electric motor.

4) Electric motor power supply cableIt is the electric cable which is connected to the panel to power the spreader motor.

5) Level indicator cableIt is the electric cable which is connected to the panel to power the vibrating level indicator.

6) Level indicator head 7) Level indicator forks The level indicator is of the vibrating type, with the head containing the operating logic installed externally on the grip of the lower cone, while the vibrating forks are connected in remote inside the spreader cone.

8) CounterweightInstalled at 180 degrees to the head of the level indicator, it is meant for balancing the weight.

SPREADER LAYOUT

2

3

1

1) Rotor Positioned at the top of the cone, its rotation helps to distribute the material inside the tanker.

2) Protection cone The cone is connected to the outlet spout and contains the electric motor, the vibrating forks of the level indica-tor, the rotor and the tubes for connection to the various utilities.

3) Electric motorIt is the motor which drives the rotor.

BELLOJET®

2.0 STANDARD VERSION OF THE MACHINE AND OPTIONS

1TOR.007.--.T.EN Issue: A

01.17

25

ELECTRICAL FEATURES OF THE MOTOR

Motor power 1.5 kWMotor speed 1400 rpm 50 Hz.Power supply 230-400 V 50 Hz. / 280-480 V 60 HzRated current (400 V 50 HZ) 3.5 ACOS PHI 0.75Efficiency 82% (IE2) Construction form B14Size 90Protection IP 55

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

26

577.5

248

1742

816

507

904838

254

629

408

3.1 Head section overall dimensions

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

27

Loader head upper flange

max

.Ø45

400

Ø30

0

15°30°

N.12 M16x40

üü

145178205

75105

138

N.4xØ9

Suction unit outlet flange

Ø25

215

Ø17

0

Ø11

Suction unit connection flange

3.2 Flange dimensions

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

28

3.3 Terminal overall dimensions

Pos

sibl

e un

load

ing

term

inal

s

Term

inal

for

tank

er w

ith

skirt

Term

inal

for t

anke

r w

ith b

otto

m c

losu

re

cone

clo

sedo

Term

inal

for

open

truc

kTe

rmin

al fo

r tan

ker

with

bot

tom

clo

sure

co

ne o

pen

ø770

ø600

ø770

768

ø810

ø600

767

8001000

ø350

ø350

437

ø610

ø750

ø610

441

ø34

655565

ø750

ø610

ø350

624310

ø610

ø610

236446

ø350

ø600

ø805

30

Term

inal

for

tank

er w

ithou

tsk

irt

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

29

3.4 Bellows lengths

ZA_B0Standard

ZA_B0with vibrating level indicator

Extended Retracted

Extended Retracted

ZA_B0with bottom closure cone

Extended Retracted

3.4.1 LOADING BELLOWS WITH DUST FILTER, DOUBLE BELLOWS WITHOUT CONES - ZA_B0

* A[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 1600 1100 26807 1880 1140 27010 2180 1180 27312 2360 1200 27415 2660 1240 27617 2940 1270 27820 3140 1300 28022 3420 1330 28225 3720 1370 28427 4000 1400 28730 4280 1440 28932 4580 1480 29135 4860 1510 293

weights

* A[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 1910 1410 27807 2190 1450 28010 2490 1490 28312 2670 1510 28415 2970 1550 28617 3250 1580 28820 3450 1610 29022 3730 1640 29225 4030 1680 29427 4310 1710 29730 4590 1750 29932 4890 1790 30135 5170 1820 303

weights

* A[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 2050 1550 30307 2330 1590 30510 2630 1630 30812 2810 1650 30915 3110 1690 31117 3390 1720 31320 3590 1750 31522 3870 1780 31725 4170 1820 31927 4450 1850 32230 4730 1890 32432 5030 1930 32635 5310 1960 328

weights

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

30

Extended Retracted

Extended Retracted

Extended Retracted

3.4.2 LOADING BELLOWS WITH DUST FILTER, DOUBLE BELLOWS - WITH INNER CONES - ZA-BA

ZA_BAStandard

ZA_BAwith vibrating level indicator

ZA_BAwith bottom closure cone

* A[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 1600 1130 27307 1880 1170 28110 2180 1220 28312 2360 1250 29015 2660 1290 29217 2940 1340 29920 3140 1370 30122 3420 1410 30825 3720 1460 31127 4000 1500 31830 4280 1550 32032 4580 1590 32835 4860 1640 330

weights

* A[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 1910 1440 28307 2190 1480 29110 2490 1530 29312 2670 1560 30015 2970 1600 30217 3250 1650 30920 3450 1680 31122 3730 1720 31825 4030 1770 32127 4310 1810 32830 4590 1860 33032 4890 1900 33835 5170 1950 340

weights

* A[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 2050 1580 31207 2330 1620 32010 2630 1670 32212 2810 1700 32915 3110 1740 33117 3390 1790 33820 3590 1820 34022 3870 1860 34725 4170 1910 35027 4450 1950 35730 4730 2000 35932 5030 2040 36735 5310 2090 369

weights

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

31

ZE_BA - ZE_B0 - ZF_BA - ZF_B0Standard

ZE_BA - ZE_B0 - ZF_BA - ZF_B0with bottom closure cone

3.4.3 LOADING BELLOWS FOR TANKER AND OPEN TRUCK

ZE_BA - ZE_B0 - ZF_BA - ZF_B0with vibrating level indicator

352.

530

In case the loading bellows is used in OPEN TRUCK mode, the bottom closure cone has to be opened using the special hooks.

Ganci di sostegnoantispreco

Antiwaste hanging hooks

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

32

Loading Bellows with vibrating level indicatorCompared to the configurations with rotary level indicator, the extended and retracted measurements are in-creased by the extent indicated, depending on the size of the forks.

3.4.5 SPREADER

Ø350

128

Ø350

STANDARD ILT - CONE PROTECTION SPREADER DEVICE

3.4.4 STANDARD FORKS VIBRATING LEVEL INDICATOR

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

33

Extended Retracted

Extended Retracted

3.4.6 LOADING BELLOWS WITH DUST FILTER, DOUBLE BELLOWS - ZC_B0

ZC_B0Standard

ZC_BAStandard

3.4.7 LOADING BELLOWS WITH DUST FILTER, DOUBLE BELLOWS - WITH INNER CONES - ZC-BA

* A1[mm]

A[mm]

B1[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 1730 2290 1230 1790 27407 2010 2570 1270 1830 27610 2310 2870 1310 1870 27912 2490 3050 1330 1890 28015 2790 3350 1370 1930 28217 3070 3630 1400 1960 28420 3270 3830 1430 1990 28622 3550 4110 1460 2020 28825 3850 4410 1500 2060 29027 4130 4690 1530 2090 29330 4410 4970 1570 2130 29532 4710 5270 1610 2170 29735 4990 5550 1640 2200 299

weights

* A1[mm]

A[mm]

B1[mm]

B[mm]

weights - Gewichtepoids - pesi

[kg]05 1730 2290 1260 1820 27907 2010 2570 1300 1860 28710 2310 2870 1350 1910 28912 2490 3050 1380 1940 29615 2790 3350 1420 1980 29817 3070 3630 1470 2030 30520 3270 3830 1500 2060 30722 3550 4110 1540 2100 31425 3850 4410 1590 2150 31727 4130 4690 1630 2190 32430 4410 4970 1680 2240 32632 4710 5270 1720 2280 33435 4990 5550 1770 2330 336

weights

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

34

The extended and retracted measures are 200 mm shorter than the standard range.

3.4.8 LOADING BELLOWS WITH SHORT FILTER - ZB-ZD-ZF

3.0 DIMENSIONS AND WEIGHTS

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

35

3.4.9 CHOOSING THE LOADING BELLOWS LENGTH

The extended length of the loading bellows must be chosen taking into account the fact that part of the loader will enter the tanker once the bottom closure cone fits all the way into the inlet spout. The Table below indicates the length of the loading bellows that enters the tanker, depending on the inlet spout diameter.

Bottom closure cone

OpenClosedØD

L

Dimensions in mm

Loading bellows with bottom closure cone

Length of section inside tank

Tank inlet diameter "D" Additional length "L"

360 367

370 376

380 385

390 394

400 403

410 412

420 421

430 430

440 439

450 448

460 457

4.0 INQUIRY FORM

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

36

TANKER LOADING

OPEN TRUCK LOADING

4.0 INQUIRY FORM

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

37

Order formCOMPANY

ORDER

MACHINE CODE DATE

Type of material

Features of materialFlowable Adhesive Degradable Hygroscopic Generates electrostatic charges

Abrasive Explosive Deteriorable Inflammable Corrosive

Place of use

Indoors Outdoors Ambient temperature: Min im u m…………°C Maxim um …………°C

Hum idity of a ir…………………………%Unloading features

Open area Train wagon Tanker truck

Ship Drum Open truck

Feed features

Conveyor belt Silo Screw conveyor

Other……………………………………..

Machine features

Max. le ngth……………...m m Min. le ngth…………………..m m Travel…………………….m m

H…………..m m T… …… ….m m U nloader s pout d iam eter D1……………….m m Tank spout diam eter…………..m m

Standard built-in filter Built-in filter short version Manual VersionManual with return (A)

Motor-operated version Voltage................V Frequency...................Hz. Manual adjoining winch (B)

Anti-spillage device Pneum atic anti-s pillage device Vibrator

Sp reader R em ovable term inal Skirt

Construction material AISI 304 AISI 316 Carbon steel

Hardox 400 Inner polyurethane lining

Special RAL paint................. Others on request..................................................

Throughput……………. Specific weight………………….Product……

4.0 INQUIRY FORM

BELLOJET®

1TOR.007.--.T.EN Issue: A

01.17

38

Electrica l features

Voltage................V Frequency...................Hz.

Electric panel Pushbutton panel

Other……………………………………..

Rotary level indicator Volt............... Vibratory level indicator Volt...........

Capacitive level indicator Volt............... Double level indicators …………………..

Others……………………………………………….

Features of bellows

Double bellows B0

Bellows material: Neoprene-Hypalon Kevlar Food-grade polyester

Filter cartridges

Cartridge material: Polyes ter Antistatic

Double bellows with internal cones BA

Junction box ATEX II 3D

N ote:..........................................................................................................................................................................................................................................................

High temperature

39