TechLine1 ASYNCHRONOUS MOTORS

16
TechLine1 ASYNCHRONOUS MOTORS We put ideas into gear. ABM Greiffenberger Antriebstechnik

description

The ABM program ofasynchronous motors comprisesthe full range of model sizes from 56 - 160, each availablein different standard lengths.

Transcript of TechLine1 ASYNCHRONOUS MOTORS

TechLine1ASYNCHRONOUS MOTORSWe put ideas into gear.ABM Greiffenberger Antriebstechnik1.Overview 32.Three-Phase AC Motors 4Rating Chart by model size and number of poles3.Two-Speed Motors5Rating Chart by model size and number of poles4.Single-Phase Motors 64.1 Rating Chart Type EK4.2 Rating Chart Type ERKK5.Brakes 76.Dimension Tables 8 - 107.Electrical Characteristics 118.Mechanical Characteristics 12 - 139.Options 14 - 15ContentsTechLine 1Asynchronous MotorsEdition 07/20072The ABM program of asynchronous motors comprisesthe full range of model sizes from 56 - 160, each avai-lable in different standard lengths. ABM motors suc-cessfully incorporate numerous developments, such asapplication specific motor windings and extruded alumi-num motor housings for compact dimensions to namejust two, essential to achieve maximum flexibility inmanufacturing of tailor-made motors.ABM asynchronous motors are available as IEC standard motors, low-energy motors, built-on motorsfor gearboxes and transmissions, rotary field magnets,special-purpose motors and low voltage AC motors(specifically for use in battery-powered vehicles).This brochure has been designed to provide an over-view of our capabilities rather than being a plain listingof the various products available.ABM Three-Phase AC Motors (D)Model size 56 - 160Rated power from 0.06 to 30 kWHigh efficiency2 - 12 pole versionsPole-changing up to 12/2 poleTypes according to IEC and customer specificEnclosure class up to IP66Special voltages 7 V to 690 VSpeeds up to 10.000 r.p.m.Temperature class FABM Single-Phase Motors (EK, ERKK)Model size 56 - 90Rated power from 0.06 to 3 kW2 and 4 pole versionsStarting capacitor and starting relay for high starting torques (ERKK)Minimal running noiseTypes according to IEC and customer specificABM Special MotorsBrake motorsLow-energy motors (EFF1)Low voltage AC motorsRotary field magnets (DG)Vibration motors (RD)Motors with integral flywheel (KD)Motors with Steinmetz connection (DEK)Vacuum-cast pot motors IP66GeneratorsInverter motorsCustom models in diecast aluminium31. Overview2. Three-Phase AC Motors44Rating ChartAll details are for S1 operation, 400 V, 50 Hz.Bold type indicates IEC standard sizes.Electrical details for duty cycles and ambient conditions not listed are available upon request or refer to sections 7 and 8 (Electrical and Mechanical Characteristics).Today, single-speed three-phase AC motors have grown in importance to become the industrial drive. Their complete freedom from maintenance, high efficiency and very favourable price/performance ratio are just three of their outstanding features. They are versatile inuse and are the standard solution for variable-speed drives, especially when used with frequency inverters.D56a 0.09 2780 0.29 57 0.06 1380 0.29 50 - - - - - - - -D56b 0.18 2770 0.52 66 0.12 1350 0.52 60 - - - - - - - -D56c 0.25 2770 0.72 66 0.18 1300 0.62 61 0.06 860 0.33 45 - - - -D63a 0.18 2770 0.48 68 0.12 1360 0.43 58 - - - - - - - -D63b 0.37 2750 0.95 70 0.25 1300 0.80 68 0.09 850 0.50 50 0.06 630 0.40 42D63c 0.55 2740 1.40 70 0.37 1300 1.10 66 - - - - - - - -D71a 0.37 2800 0.95 74 0.25 1360 0.72 68 0.12 850 0.52 50 0.09 650 0.50 47D71b 0.55 2830 1.33 77 0.37 1370 1.05 70 0.18 880 0.87 56 0.12 670 0.80 40D71c 0.75 2800 1.70 74 0.55 1330 1.45 70 - - - - - - - -D80a 0.75 2770 1.80 74 0.55 1340 1.50 68 0.37 870 1.25 59 0.18 660 0.86 51D80b 1.1 2760 2.60 75 0.75 1360 2.00 72 - - - - - - - -D80c - - - - - - - - 0.55 860 1.70 61 0.25 660 1.10 55D80e 1.5 2810 3.35 79 1.1 1370 2.90 75 0.75 880 2.40 63 0.37 660 1.40 57D90Sa 1.5 2810 3.30 78 1.1 1370 2.70 75 0.75 895 2.20 68 0.37 670 1.35 60D90Sb 2.2 2800 4.80 80 1.5 1390 3.60 78 1.1 890 3.10 67 0.55 670 1.90 64D90La 2.2 2800 4.80 80 1.5 1390 3.60 78 1.1 890 3.10 67 0.55 670 1.90 64D90Lb 3 2810 6.50 82 2.2 1370 5.20 78 1.3 900 3.70 68 0.75 670 2.70 64D100La 3 2860 6.60 82 2.2 1410 5.10 79 1.5 910 4.00 77 1.1 670 3.80 69D100Lb 4 2880 8.40 86 3 1410 6.60 84 - - - - - - - -D100Lc 5.5 2860 11.5 87 4 1410 8.40 83 2.2 920 5.40 78 1.5 680 4.70 71D112Mb 5.5 2890 11.0 84 5.5 1430 11.0 86 - - - - - - - -D112M 7.5 2880 14.5 85 7.5 1430 16.0 85 - - - - - - - -D112Me 9.5 2890 18.5 87 - - - - - - - - - - - -D132Mc 11 2920 22.0 89 - - - - - - - - - - - -D132Mb - - - - 7.5 1450 16.2 86 - - - - - - - -D132Mc - - - - 11 1445 24.0 87 - - - - - - - -D132Md 15 2900 29.0 89 - - - - - - - - - - - -D132L - - - - 15 1460 32.0 87 - - - - - - - -D160MR 15 2920 28.0 88 11 1450 22.5 88 7.5 970 16.5 85 5.5 715 13.0 84D160LR 18.5 2930 34.0 89 15 1460 28.5 88 11 965 23.0 85 7.5 720 17.0 86D160LbR - - - - 18.5 1460 37.0 88 - - - - - - - -P[kW]Motor Type(model size)I[A] [%]P[kW]I[A] [%]P[kW]n[r.p.m.]n[r.p.m.]n[r.p.m.]n[r.p.m.]I[A] [%]P[kW]I[A] [%]2 pole/ 3000 r.p.m. 4 pole/ 1500 r.p.m. 6 pole/ 1000 r.p.m. 8 pole/ 750 r.p.m.1500/3000 4/2 16 D/SS 750/1500 8/4 1 6D/SS750/30008/2 2 6 S/S 500/3000 12/2 2 6 S/S5All details are for S1 operation, 400 V, 50 Hz.Exception: The 12/2 pole motors are designed for S3 operation - 15/25%, typically used for hoist motors.Model sizes and specifications for other pole numbers upon request.2. Drehstrommotoren 3. Two-Speed MotorsTwo-speed motors are used when different speeds are required. These depend on the motor's number of poles. The table shows the speeds in which these motors are available. Other speed ratios or multiple speeds are also possible. The listed versions of our two-speed motors are designed for direct starting.Typical Applications: Hoisting and traversing gearKitchen appliancesConveyor beltsCircular sawsPower drillsGeneral 2-speed drive applicationsNumber of polesNumber of windingsNumber of terminalsGraphic symbolSpeed steps inr.p.m.Rating ChartD56b 0.06/0.09 0.29/0.29 - - - - - -D63a 0.09/0.12 0.40/0.38 - - - - - -D63b 0.12/0.18 0.48/0.51 - - - - - -D71a 0.18/0.25 0.60/0.75 - - 0.04/0.18 0.34/0.70 - -D71b 0.25/0.37 0.81/1.05 - - 0.06/0.25 0.43/0.80 - -D71c 0.37/0.55 0.76/0.88 - - 0.09/0.37 0.81/1.15 - -D80a 0.45/0.60 1.15/1.4 0.18/0.25 0.95/0.71 - - - -D80b 0.6/0.8 1.55/1.9 - - 0.12/0.55 0.67/1.52 - -D80c - - 0.25/0.37 1.15/0.95 - - - -D80e 0.75/1.1 2.2/2.9 - - 0.18/0.75 0.95/2.0 - -D90Sa 0.75/1.1 1.9/2.65 - - 0.18/0.75 1.05/1.8 - -D90Sb 1.1/1.5 2.7/3.5 0.37/0.55 1.8/1.45 0.25/1.1 1.25/2.6 - -D90Lb 1.5/2.2 3.6/4.8 0.55/0.75 2.2/1.8 0.37/1.5 1.7/3.5 - -D100La 2.0/2.5 4.6/5.5 0.9/1.5 3.1/3.5 - - - -D100Lb 2.6/3.2 5.7/6.7 - - 0.55/2.2 2.2/4.8 0.4/2.5 2.6/5.9D100Lc 3.3/4.1 6.9/8.1 1.4/2.2 4.3/5.0 0.75/3.0 2.9/6.3 0.45/3.2 2.7/7.2D112Mb 4.4/5.3 9.2/11.0 1.9/3.0 5.2/7.0 1.1/4.0 3.8/9.0 0.7/4.9 5.5/12D132Mb 6.2/7.5 14/17 - - 1.5/5.5 5.5/12.5 0.9/6.0 5.5/14D132Md 8/11 18/22 - - 2.2/7.5 7.4/16 1.5/9.5 9/22D160MR 8/11 15.5/22 6/8 13.5/16 2.2/7.5 7.1/16 - -D160LR 11/15 21/29 7.5/11 17.5/23 3/11 9.5/22 2.6/16 15/338/4 pole750/1500 r.p.m.Dahlander circuit D/SS4/2 pole1500/3000 r.p.m.Dahlander circuit D/SSP[kW]Motor type(model size)I[A]P[kW]I[A]P[kW]P[kW]I[A]I[A]12/2 pole500/3000 r.p.m.2 separate windings S/S8/2 pole750/3000 r.p.m.2 separate windings S/S4. Single-Phase Motors64.1 TYPE EKSingle-phase motors with running capacitor. This type has a locked-rotor torque from 40 to 70% depending on the size of the motor. The starting current is around 3 to 4.5 times the rated current: These motors are ideal for machines that start easily.Typical Applications Blowers PumpsCompressors4.2 TYPE ERKKSingle-phase motors with running capacitor, auxiliary winding, starting capacitor and current-dependent starting relay offer particularly favourable performance for heavy starting. The locked-rotor torque is approx.200%. The starting current is approx. 3 to 4.5 times the rated current. Application Examples Screw conveyorsMetering systemsAgitatorsRating ChartRating ChartOther versions, e.g. Type ERK (single-phase motor with auxiliary winding, integral starting relay and starting capacitor) upon request.All details are for S1 operation,230 V, 50 Hz. Electrical details for duty cycles and ambient conditions not listed are availableupon request or refer to sections7 and 8 (Electrical andMechanical Characteristics).All details are for S1 operation,230 V, 50 Hz. Electrical details for duty cycles and ambient conditions not listed are availableupon request or refer to sections7 and 8 (Electrical andMechanical Characteristics).ERKK71b 0.37 2.4 12+25 0.25 1.8 12+20ERKK71c 0.55 3.6 16+40 0.37 2.65 16+25ERKK80b 0.75 5.0 25+80 0.55 3.9 20+50ERKK80e 1.1 7.0 30+100 0.75 5.2 25+80ERKK90Sb 1.5 9.5 40+120 1.1 7.4 40+100ERKK90 Lb2.2 12.9 50+160 1.5 9.6 50+120Motor Type(model size)P[kW]I[A]CB+ CA[F]P[kW]I[A]CB+ CA[F]4 pole/ 1500 r.p.m.Type ERKK with running capacitor,starting capacitor and starting relay2 pole/ 3000 r.p.m.Type ERKK with running capacitor,starting capacitor and starting relayP[kW]I[A]CB[F]P[kW]I[A]CB[F]2 pole/ 3000 r.p.m.Type EK with running capacitor4 pole/ 1500 r.p.m.Type EK with running capacitorEK56a 0.09 0.72 3 0.06 0.62 4EK56b 0.12 1.0 5 0.09 0.85 5EK63a 0.18 1.5 5 0.12 1.05 6EK63b 0.25 1.7 10 0.18 1.45 8EK71b 0.37 2.4 12 0.25 1.8 12EK71c 0.55 3.6 16 0.37 2.65 16EK80b 0.75 5.0 25 0.55 3.9 20EK80e 1.1 7.0 30 0.75 5.2 25EK90Sb 1.5 9.5 40 1.1 7.4 40EK90Lb2.2 12.9 50 1.5 9.6 50Motor Type(model size)75. BrakesABM disk brakes type EFB and ZFB are electro-mechanical safety brakes and stop drives quickly and reliably in any operating mode. There can be no compromises when it comes to safety, and ABM have been developing and manufacturing brakes for 60 years. This experience has resulted in the continuous improvement of brake performance. All brake components and functions are perfectly matched to a particular drive.The main characteristics and benefits for the user includeAdjustable torqueSafe braking in the event of a power lossSimple manual adjustmentUnlimited continuous dutyAsbestos-free brake liningHigh operating frequencyLong lining lifeShort On and Off timesTypical ApplicationsCranes, hoistsHandling and conveying systemsMachine tools Packaging machinesTextile machinery Warehousing systemsOptionsManual ventilation in position A, B, C or D High-speed excitationFriction plate corrosion-protectedDisk Brake Cross-References56 0.9 - 3 EFB 163 0.9 - 3 EFB 171 0.7 - 7.5EFB 24 - 10 ZFB 1080 0.7 - 7.5EFB 24 - 10 ZFB 108 - 20ZFB 2090 S / 1.3 - 25 EFB 390 L 8 - 20ZFB 2016 - 40ZFB 40100 1.3 - 25EFB 316 - 40ZFB 4028 - 60 ZFB 60112 M / 16 - 40 ZFB 40112 Me 28 - 60 ZFB 60132 Md / 28 - 60 ZFB 60132 L 40 - 100 ZFB 10060 - 150 ZFB 150160 M / 60 - 150 ZFB 150160 L 110 - 250 ZFB 250motormodel sizebraking torques[Nm]typeMethod of OperationOn ABM EFB disk brakes (single-sided brake) the brakecoiliscastintotheendshieldonthebrakeside.An aluminium impeller acts as brake lining carrier. In de-energized condition a thrust spring supported off thebrakeendshieldpressesanaxiallymovingarmaturebase plate against a special brake lining on the impeller.ABM ZFB disk brakes (2 sided brake) are mounted on thebrake side end shield that also acts as one of the brakepads. Alloy brake disks have a special lining on both faces andliebetweenendshieldandmagnetbodywitharmaturebase plate. In de-energized condition a number of springspress the armature base plate against the brake disk andbring it into contact with the end shield.Supply VoltagesThe standard supply is 230 V AC, 50 Hz when connectedtotherectifier.Othersupplyvoltagesuponrequest. Thebrake'sOFFtimecanbeadaptedtoindividual applications by AC side or DC side switching, i.e. makingpreciserapidbrakingordelayedsoftbrakingpossible.Theoperatingtimecanbereducedwithahigh-speedexcitation rectifier.86. Dimension TablesDimensions of conventional motors according to DIN EN 50347Type : B 3, B 6, B 7, B 8, V 5, V 6Dimensions in mmIllustrations are for reference only and subject to change.The dimensional tables are for the following motor types:Three-phase AC MotorsSingle-phase motors without capacitor(s)Two-speed motorsDimensions AD and HB apply to plastic junction box. Dimensions AD and HB apply to the aluminum junction box. Keyway dimensions according DIN 6885 sheet 1.56 90 110 94 112 71 36 9 20 56 54 66 111 - 6 188 EFB 3563 100 124 96 112 80 40 11 23 63 45 53 125 - 7 209.5 EFB 32.571 112 139 101 117 90 45 14 30 71 40 47.5 140.5 - 7 237 EFB 40ZFB 54.580 125 158 108 124 100 50 19 40 80 40 47.5 159 - 10 273 EFB 40ZFB 67.590S 140 177 122 140 100 56 24 50 90 51 57.5 178.5 - 10 299.5 EFB 56.5ZFB 7790L 140 177 122 140 125 56 24 50 90 51 57.5 178.5 - 10 324.5 EFB 56.5ZFB 77100L 160 196 130 148 140 63 28 60 100 51 57.5 198 233 12 369 EFB 56.5ZFB 96112M 190 220 140 158 140 70 28 60 112 51 57.5 222 254 12 389 ZFB 86.5112Me 190 220 140 158 190 70 28 60 112 51 57.5 222 254 12 458 ZFB 86.5132S 216 262 181 190 140 89 38 80 132 73 84 263 308 12 456 ZFB 109132M 216 262 181 190 178 89 38 80 132 73 84 263 308 12 494 ZFB 109132Md 216 262 181 190 178 89 38 80 132 73 84 263 308 12 524 ZFB 109132L 216 262 181 190 248 89 38 80 132 73 84 263 308 12 564 ZFB 109160M 254 310 - 238 210 108 42 110 160 - 84 315 364 13 587 ZFB 124160L 254 310 - 238 254 108 42 110 160 - 84 315 364 13 631 ZFB 124modelsizeA AC AD AD B C D E H HB HB HC HD K Lbraketype L56 - 80 1x M16 x 1.5 resp. 2x M16 x 1.5 on motor with brake 1x 20 resp. 2x 20 on motor with brake90 - 100 1x M20 x 1.5 resp. 2x M 20 x 1.5 on motor with brake 1x 25 resp. 2x 25 on motor with brake112 2x M20 x 1.5 2x 25132 - 160 2x M25 x 1.5 2x M25 x 1.5Motor Type(model size)Holes for cable connection(s) in plastic junction boxHoles for cable connection(s) in aluminum junction box9Dimensions of flanged motors according to DIN EN 50347Type: B 5 (V1, V3)Dimensions in mmIllustrations are for reference only and subject to change.The dimensional tables are for the following motor types:Three-phase AC MotorsSingle-phase motors without capacitor(s)Two-speed motorsDimensions AD and HB apply to plastic junction box. Dimensions AD and HB apply to the aluminum junction box. Keyway dimensions according DIN 6885 sheet 1.56 110 90 106 9 20 40 47.5 - 188 100 80 120 7 3 EFB 3563 124 96 112 11 23 40 47.5 - 209.5 115 95 140 9,5 3 EFB 32.571 139 101 117 14 30 40 47.5 - 237 130 110 160 9,5 3.5 EFB 40ZFB 54.580 158 108 124 19 40 40 47.5 - 273 165 130 200 11,5 3.5 EFB 40ZFB 67.590S 177 122 140 24 50 51 57.5 - 299.5 165 130 200 11,5 3.5 EFB 56.5ZFB 7790L 177 122 140 24 50 51 57.5 - 324.5 165 130 200 11,5 3.5 EFB 56.5ZFB 77100L 196 130 148 28 60 51 57.5 133 369 215 180 250 14 4 EFB 56.5ZFB 96112M 220 140 158 28 60 51 57.5 142 389 215 180 250 14 4 ZFB 86.5112Me 220 140 158 28 60 51 57.5 142 458 215 180 250 14 4 ZFB 86.5132S 262 181 190 38 80 73 84 176 456 265 230 300 14 4 ZFB 109132M 262 181 190 38 80 73 84 176 494 265 230 300 14 4 ZFB 109132Md 262 181 190 38 80 73 84 176 524 265 230 300 14 4 ZFB 109132L 262 181 190 38 80 73 84 176 564 265 230 300 14 4 ZFB 109160M 310 - 238 42 110 - 84 204 587 300 250 350 18 5 ZFB 124160L 310 - 238 42 110 - 84 204 631 300 250 350 18 5 ZFB 124modelsizeAC AD AD D E HB HB HD L M N P S Tbraketype L2. Drehstrommotoren106. Dimension tables continuedDimensions of the flange motors to DIN EN 50347Type: B 14 (V18, V19)Dimensions in mm56 110 90 106 9 20 40 47.5 - 188 65 50 80 M5 2.5 EFB 3563 124 96 112 11 23 40 47.5 - 209.5 75 60 90 M5 2.5 EFB 32.571 139 101 117 14 30 40 47.5 - 237 85 70 105 M6 2.5 EFB 40ZFB 54.580 158 108 124 19 40 40 47.5 - 273 100 80 120 M6 3 EFB 40ZFB 67.590S 177 122 140 24 50 51 57.5 - 299.5 115 95 140 M8 3 EFB 56.5ZFB 7790L 177 122 140 24 50 51 57.5 - 324.5 115 95 140 M8 3 EFB 56.5ZFB 77100L 196 130 148 28 60 51 57.5 133 369 130 110 160 M8 3.5 EFB 56.5ZFB 96112M 220 140 158 28 60 51 57.5 142 389 165 130 200 M10 3.5 ZFB 86.5112Me 220 140 158 28 60 51 57.5 142 458 165 130 200 M10 3.5 ZFB 86.5132S 262 181 190 38 80 73 84 176 456 215 180 250 M12 4 ZFB 109132M 262 181 190 38 80 73 84 176 494 215 180 250 M12 4 ZFB 109132Md 262 181 190 38 80 73 84 176 524 215 180 250 M12 4 ZFB 109132L 262 181 190 38 80 73 84 176 564 215 180 250 M12 4 ZFB 109modelsizeAC AD AD D E HB HB HD L M N P S Tbraketype LIllustrations are for reference only and subject to change.The dimensional tables are for the following motor types:Three-phase AC MotorsSingle-phase motors without capacitor(s)Two-speed motorsDimensions AD and HB apply to plastic junction box. Dimensions AD and HB apply to the aluminum junction box. Keyway dimensions according DIN 6885 sheet 1.117. ElectricalCharacteristicsRated PowerThe power ratings given in the lists are the power output according to VDE0530 for continuous operation S1; frequency 50 Hz; max. room temperature 40C; max. site altitude 1000 m abovesea level.Rated Voltage and FrequencyThestandardvoltageratingsare230/400Vor400/690Vandratedfrequency50Hz.Voltagefluctuations within+/-10%arepermitted.Specialvoltagesandspecialfrequenciesareavailableforexport,inverter operation and use in battery-powered machines.Two-speedmotors,especiallythosewithDahlandercircuits,aredesignedforonevoltageonly.Theyaresupplied for power supply 230 V or 400 V at 50 Hz. Other voltages or frequencies are possible. Motors withtwoseparatewindingscanbedesignedfortwovoltagesintheratioof1:1.73.Furtherdetailsupon request.Outputs for single-phase motors are based on a rated voltage of 230 V, 50 Hz. Rated Currents and EfficienciesCurrents and efficiencies given in Table 1 are based on a rated voltage of 400 V / 50 Hz and full-load rating.If the rated voltage changes the rated current is converted as follows: J = 400 x J / UStarting Current and Starting TorqueStarting torques and currents are a multiple of the rated values with direct starting.Overload CapacityInaccordancewithVDE0530themotorscanwithstand2minutesat1.5timesratedcurrentatrated-load operating temperature without damage to the winding.Motor TorqueThe motor torque output at the shaft in Nm is:T [Nm] = 9550 x P [kW] / n [r.p.m.]Temperature ClassABM electric motors are manufactured using high-grade "Overcoat" enamelled wire and wrapper material in conjunctionwithsolvent-freeresinimpregnationandmeettemperatureclassF.Maximumtemperatureis155C.A line-sidecircuit-breakerwithovertemperatureswitchprovidesthemotorwithreliable protectionintheeventofanoverload.Forsevereoperatingconditions(e.g.convertermode,veryhigh inertiastartingandswitchingoperationswithmorethan100c/h)werecommendtheuseoftemperature sensors PTC thermistors (see Options, Section 9).2. Drehstrommotoren122. Drehstrommotoren 8. Mechanical CharacteristicsShaft EndsThe standard version has a straight shaft end. Key ways have been installed prior to rotor balancing. The typeof balancing method is indicated on the rating plate after product number.H...half key way (standard), F...full key waySecond shaft end and special shafts upon request.Mechanical Balance QualityTherotorsaredynamicallybalancedasmarkedandmeetvibrationseveritygrade A (DINEN60034-14). Motors can be supplied for vibration severity grade B (Reduced) for special quietness requirements.Standards and RegulationsABM electric motors conform to all relevant standards and regulations:Maximum Radial Forces Fr [N]Valuesarebasedonthecentreofthestandardoutputshaftendwhenopera-ting at 50 Hz.56 230 270 310 -63 230 300 350 38071 260 320 370 40080 350 450 520 56090 550 750 860 920100 770 950 1090 1170112 900 1110 1270 1360132 1140 1400 - -160 -2500 2800 3100Fr [N]2 polemodelsizeFr [N]4 poleFr [N]6 poleFr [N]8 poleCylindrical Shaft Ends; Dimensions, Nominal Transmissible Torques DIN 748-1 -Surface cooled squirrel cage three phase induction motors, type of construction IM B3, DIN 42673-3 - -with roller bearings, mounting dimensions and output classification Surface cooled squirrel cage three phase induction motors, type of construction B3, DIN 42673-4 - -with roller bearings, size of envelope Totally enclosed fan-cooled alternating-current polyphase motors with squirrel-cage,DIN 42677-4 - -design B5, B10, B14, with ball bearings; maximum envelope dimensions for design B5, B14Tolerances of shaft extension run-out and of mounting flanges for rotating electrical DIN 42955 - -machinery, testGeneral purpose three-phase induction motors having standard dimensions andDIN EN 50347 - -outputs - Frame numbers 56 to 315 and flange numbers 65 to 740Rotating electrical machines - Part 1: Rating and performanceDIN EN 60034-1 VDE 0530 Part 1 IEC 60034-1Rotating electrical machines - Part 5: Degrees of protection provided by the integral DIN EN 60034-5 VDE 0530 Part 5 IEC 60034-5design of rotating electrical machines (IP code)Rotating electrical machinery - part 6: Classification of cooling method (IC-code) DIN EN 60034-6 VDE 0530 Part 6 IEC 60034-6Rotating electrical machines - Classification of types of constructions and mountingDIN EN 60034-7 VDE 0530 Part 7 IEC 60034-7arrangements (IM Code)Rotating electrical machines - Part 8: Terminal markings and direction of rotationDIN EN 60034-8 VDE 0530 Part 8 IEC 60034-8Rotating electrical machines - Part 9: Noise limits DIN EN 60034-9 VDE 0530 Part 9 IEC 60034-9Rotating electrical machines - Thermal protection DIN EN 60034-11 VDE 0530 Part 11 IEC 60034-11Rotating electrical machines - Part 12: Starting performance of single-speed three-phaseDIN EN 60034-12 VDE 0530 Part 12 IEC 60034-12cage induction motorsRotating electrical machines - Part 14: Mechanical vibration of certain machines withDIN EN 60034-14 VDE 0530 Part 14 IEC 60034-14shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severityDegrees of protection provided by enclosures (IP code) DIN EN 60529 VDE 0470 Part 1 IEC 60529Mechanical vibration; balancing; shaft and fitment key convention DIN ISO 8821 - -Title DIN VDE IEC13ConfigurationsIllustrations show terminal box position A (standard unless otherwise specified). Terminal box position B, C and D per customer specification. Cable entry can be rotated in 90 steps.Example: B 3 / A 1 means terminal box on the right side of the motor looking from shaft end, cable entry is from underneath.Notes on the terminal box position and cable entry:With foot motors terminal box position B is not avaiable, position D is available up to model size 90 only and with position C the terminal box moves to the fan end.Foot motorExample of terminal boxposition andcable entryFlanged motor Example of terminal boxposition andcable entryngAvailable Flange DiametersThe dimensions marked * are not according to DIN standard. Other flange sizes upon request.Horizontal shaft arrangementVertical shaft arrangementB 35 B 9 B 15 B 3 B 5 B 8 B 6 B 14V 9 V 19 V 1 V 5 V 6 V 18 V 3 V 856 120 80, 105, 90*, 120*63 140, 120* 90, 120, 80*, 105*, 140*71 160, 120*, 140* 105, 140, 80*, 90*, 120*80 200, 160* 120, 160, 105*, 140*90 200, 160* , 250* 140, 160, 105*, 120*100 250, 160*, 200* 160, 200, 140*112 250, 200*, 300* 160, 200, 250*132 300, 250*, 350* 250*160 350, 300*-model size B5 / V1 / V3 / B35 [mm]B14 / V18 / V19 / B34 [mm] B 7PTC Thermistors according to DIN 44081Three thermistors encapsulated in one winding head (1 per phase) offer the most effective protection against motor overheating. External controllers can be connected in the motor junction box. Nominal motor operating temperature is 155 C.Temperature SensorsTemperature sensors open an electric circuit when a pre-determined, non-adjustable temperature is reached. Temperature sensors complying with VDE 0631 are used:Type S01 250V; 50 Hz; 1.6 A at cos = 0.6; 2.5 A at cos= 1Type S06 250V; 50 Hz; 6.3 A at cos = 0.6; 10 A at cos= 1Motor current direct-on-line starting (single-phase motors only)Temperature Measurements with KTY-SensorsKTY sensors allow measurements of winding temperature for status monitoring. Sensor resistance changeswith the temperature allowing exact measurements over a wide temperature range. Type KTY 84-130 can be directly monitored by ABM inverter controllers type LDC CDA/CDB).Junction BoxPlasticjunctionboxesarestandard.Uponcustomerrequestaluminumjunctionboxeswithintegrated rectifiers can be supplied with brake motors.Custom Output ShaftsIn addition to straight shafts per DIN 748 custom shaft ends for custom applications are available.Elevated Protection ClassInadditiontostandardenclosureprotectionclassesperVDE0530,elevatedprotectionforaggressive environments such as damp locations, dairies and high humidity are available.Coats of PaintMotor housings and end shields of ABM electric motors are made from corrosion-resistant aluminum. Junction boxes and fan shrouds are made from black plastic. Typically, painting is not required. The following standardcoast of paint colors are available (1K acrylic paint): RAL 7031 (Blue grey), RAL 2002 (Vermilion), RAL 5017 (Traffic Blue), RAL 6011 (Reseda green), RAL 9005 (Jet black) and RAL 9010 (Pure white). Other finishes upon request.Rotary Encoders HTL encoder (24 V signal) with 1024 pulses, A and B channel for frequency converter applications. Sin - Cos - encoder (1 Vss) with 1024 pulses A, A, B, B, 0, 0 channels for applications with servo-converter. Integrated sensor bearings from world known manufacturers TTL-encoder (5 V level signal) with 1024 pulses, A, A, B, B; 0, 0 channels for use with positioning inverters.Other encoders and pulse counts available upon request.149. Options15Forced VentilationAuxiliary,electricalfansareusedshouldthemotor'sownfanbeinadequateincooling.Thisappliesto severe working conditions such as automatic operation, low speeds (frequency inverter operation) or frequentswitching. Each auxiliary fan consists of sturdy motor/fan unit, its own junction box, a galvanized metal shroud and glass fiber reinforced polyamide fan blades and meets IP66 enclosure class. Junction boxes can be rotated to all positions and cable entry M16x1.5 is available in positions 1 and 3.Power supplies:3 AC 220-290 V / 380-500 VD/S,50/60 Hz1 AC 230-277 V, 50/60 Hz (Steinmetz circuit)Dimensions of auxiliary fans in mm:63standard+71.5124107115.0EFB 1 +91.571standard+70.5 139107 122.5EFB 2 +95.0 ZFB 10 +80.5 80standard +65.0157107 131.5EFB2+95.0 ZFB 10, ZFB 20+67.5 ZFB 20+97.0177117141.590standard+70.0177 117141.5EFB 3+101.0 ZFB 20, ZFB 40+80.5 100standard +64.5195117 150.5EFB 3+103.5 ZFB 40, ZFB 60+64.0 ZFB 60+70.0219162.5112standard +58.5219117 162.5ZFB 40, ZFB 60+69.5 132 standard +99.0258127184.0ZFB 40, 60, 100, 150+98.0 160standard +105.0311127210.5ZFB 60, 150, 250+96.0 model size typeL to ventilatedmotorAC [mm] g [mm]AD[mm] We put ideas into gear.ABM Greiffenberger AntriebstechnikThis is how you can contact us:ABM Greiffenberger Antriebstechnik GmbHPostfach 140 95614 MarktredwitzFriedenfelser Strae 24 D - 95615 MarktredwitzTelephone:(49) 0 92 31/67-0(Reception)Telefax:(49) 0 92 31/6 71 45(Sales)(49) 0 92 31/6 72 02(Technical Sales)(49) 0 92 31/6 32 21(Service dep.)e-mail: [email protected] Germany: http://www.abm-antriebe.deInternet International: http://www.abm-drives.comOther agencies:Belgium Italy Denmark Sweden (Contact details available on request!)ABM in your proximity:Austria:ABM Antriebstechnik GmbHOrtsstrae 18/1/5-7A - 2331 VsendorfPhone (43) 01 - 6 99 11 620 Fax(43) 01 - 6 99 11 62 23 e-mail: [email protected]:ABM Systmes d`Entranement S.A.R.L.40, rue Jean Monnet Melpark Bat. 5F - 68200 MulhousePhone (33) 03 - 89 33 44 01 Fax(33) 03 - 89 33 44 05e-mail: [email protected] America:ABM DRIVES INC.2000 Ford Circle Suite EUSA - Milford, OH 45150Phone (1) 513 - 576 - 1300 Fax(1) 513 - 576 - 4999 e-mail: [email protected]:ABM Greiffenberger Antriebstechnik AGOholten 3CH - 5703 SeonPhone (41) 0 62 - 775 09 60 Fax(41) 0 62 - 775 09 66 e-mail: [email protected] Netherlands:ABM Nederland Aandrijftechniek B.V.Postbus 108, Industrieweg 6NL - 3440 AC WoerdenPhone (31) 03 48 - 41 73 41Fax(31) 03 48 - 42 25 16 e-mail: [email protected]. China:ABM Drives (Suzhou) Co., Ltd.Kuachun Industrial Area Unit 9GChun Hui Lu, Weiting TownP.R. China - 215122 SuzhouPhone (86) 137-7199 3697e-mail: [email protected]